diff options
Diffstat (limited to 'MIBS/bintec/BIANCA-BRICK-MIB')
| -rw-r--r-- | MIBS/bintec/BIANCA-BRICK-MIB | 3018 |
1 files changed, 3018 insertions, 0 deletions
diff --git a/MIBS/bintec/BIANCA-BRICK-MIB b/MIBS/bintec/BIANCA-BRICK-MIB new file mode 100644 index 0000000..d45120b --- /dev/null +++ b/MIBS/bintec/BIANCA-BRICK-MIB @@ -0,0 +1,3018 @@ +-- This file is corresponding to Release 10.2.3.100 from 2018/07/18 00:00:00
+
+
+-- (C)opyright 1991-2017 bintec elmeg GmbH, All Rights Reserved
+-- $Revision: 1.56.1.2 $
+
+BIANCA-BRICK-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
+ Integer32, Unsigned32, Counter32, Gauge32, Counter64,
+ IpAddress, TimeTicks, mib-2, enterprises
+ FROM SNMPv2-SMI
+
+ DisplayString, TimeStamp, TruthValue
+ FROM SNMPv2-TC
+
+ bintec, bibo, sys, Date, HexValue
+ FROM BINTEC-MIB
+
+ TRAP-TYPE
+ FROM RFC-1215
+
+
+ sysDescr, sysName
+ FROM SNMPv2-MIB
+
+ ;
+
+ biboMIB MODULE-IDENTITY
+ LAST-UPDATED "201703240000Z"
+ ORGANIZATION
+ "bintec elmeg GmbH"
+ CONTACT-INFO
+ "EMail: info@bintec-elmeg.com
+ Web: www.bintec-elmeg.com
+ "
+ DESCRIPTION
+ "MIB module for vendor specific box definitions.
+ Note: bibo stands for BinTec box stemming from the times where
+ the company was still called BinTec."
+ REVISION "201004280000Z"
+ DESCRIPTION
+ "First version conforming to SMIv2."
+ ::= { bintec 250 }
+
+ -- This MIB module uses the extended OBJECT-TYPE macro as
+ -- defined in [14];
+
+
+ -- MIB-II (same prefix as MIB-I)
+ admin OBJECT IDENTIFIER
+ ::= { bibo 1 }
+
+ -- Some variables for administration of the BIANCA/BRICK
+
+-- biboAdmTrapCommunity OBJECT-TYPE
+-- SYNTAX DisplayString (SIZE (0..255))
+-- MAX-ACCESS read-write
+-- STATUS mandatory
+-- - BINTEC NOTRAP
+-- DESCRIPTION
+-- "Community name for sending traps."
+-- DEFVAL { "snmp-Trap" }
+-- ::= { admin 4 }
+--
+-- biboAdmSnmpVersion OBJECT-TYPE
+-- SYNTAX INTEGER { version1(1),
+-- version1-compat(2),
+-- version1p1(3),
+-- version1p1-compat(4),
+-- version1p1-auto(5)
+-- }
+-- MAX-ACCESS read-write
+-- STATUS mandatory
+--
+-- DESCRIPTION
+-- "SNMP Version.
+-- version1 : SNMP version V1
+-- version1_compat : SNMP version V1 compatibility mode
+-- without the appending private OID
+-- part (.i). This is for some SNMP managers
+-- that cannot handle this extension.
+-- In this mode rows with identical
+-- index variable content cannot be read
+-- correctly.
+-- p1 (patch1) : getnext returns the lexicographical next
+-- OID (ever!)
+-- version1p1_auto : use version1p1_compat if possible
+-- use version1p1 if nessesary
+--
+-- Usually the OIDs have the format:
+-- .1.3.6.x.x .y.y .i
+--
+-- .1.3.6.x.x: is the constant part of the OID of the
+-- variable specified in MIB-source
+-- .y.y : is the specific part of the OID to identify
+-- exactly a row.
+-- It is the content of all index variables.
+-- .i : is a consecutively incremented index number,
+-- to distinguish rows with identical index variables
+-- "
+-- DEFVAL { version1p1-auto }
+-- ::= { admin 5 }
+--
+-- biboAdmSnmpPort OBJECT-TYPE
+-- SYNTAX INTEGER
+-- MAX-ACCESS read-write
+-- STATUS current
+--
+-- DESCRIPTION
+-- "SNMP listen port."
+-- DEFVAL { 161 }
+-- ::= { admin 6 }
+--
+-- biboAdmSnmpTrapPort OBJECT-TYPE
+-- SYNTAX INTEGER
+-- MAX-ACCESS read-write
+-- STATUS current
+-- - BINTEC NOTRAP
+-- DESCRIPTION
+-- "SNMP trap port."
+-- DEFVAL { 162 }
+-- ::= { admin 7 }
+
+ biboAdmIpAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "Local IP address. If this object is set, it's value will be
+ used as the source address for all IP packets that are sent.
+ Otherwise, the IP address used will be retrieved from the
+ ipRouteTable, for the interface the IP packet is to be
+ transmitted over."
+ ::= { admin 8 }
+
+-- biboAdmTrapBrdCast OBJECT-TYPE
+-- SYNTAX INTEGER { on(1), off(2) }
+-- MAX-ACCESS read-write
+-- STATUS current
+-- - BINTEC NOTRAP
+-- DESCRIPTION
+-- "Enable/disable trap broadcasting."
+-- DEFVAL { off }
+-- ::= { admin 9 }
+
+ biboAdmTrapHostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BiboAdmTrapHostEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+
+ DESCRIPTION
+ "The biboAdmTrapHostTable defines where traps are sent
+ (i.e., which hosts). If the table is empty traps are
+ broadcasted.
+
+ Creating entries: Entries are added by assigning an IP
+ address value to the biboAdmTrapHostAddr field.
+
+ Deleting entries: Entries can be removed by assigning
+ ing the respective biboAdmTrapHostStatus field to
+ 'delete'."
+ ::= { admin 10 }
+
+ biboAdmTrapHostEntry OBJECT-TYPE
+ SYNTAX BiboAdmTrapHostEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { biboAdmTrapHostAddr }
+ ::= { biboAdmTrapHostTable 1 }
+
+ BiboAdmTrapHostEntry ::= SEQUENCE {
+ biboAdmTrapHostAddr IpAddress,
+ biboAdmTrapHostStatus INTEGER
+ }
+
+ biboAdmTrapHostAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "Ip-Address where traps are sent."
+ ::= { biboAdmTrapHostEntry 1 }
+
+ biboAdmTrapHostStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ valid(1),
+ delete(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "Status is always valid, and set to delete only to discard
+ the whole entry."
+ DEFVAL { valid }
+ ::= { biboAdmTrapHostEntry 2 }
+
+ biboAdmSyslogMaxEntries OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "Maximum Number of syslog messages stored in memory."
+ DEFVAL { 20 }
+ ::= { admin 11 }
+
+ biboAdmSyslogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BiboAdmSyslogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The biboAdmSyslogTable keeps track of syslog messages
+ received. The size of the table (number of entries), is
+ limited by the value of biboAdmSyslogMaxEntries. The
+ columns specify attributes for each message generated. As
+ this information only reports events on the system, all
+ fields are read-only.
+
+ Creating entries: Entries can only be created by the
+ system and are made each time a syslog message is
+ generated.
+
+ Deleting entries: Entries are removed by the system
+ once the size limit (biboAdmSyslogMaxEntries) is reached."
+ ::= { admin 12 }
+
+ biboAdmLogHostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BiboAdmLogHostEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+
+ DESCRIPTION
+ "The biboAdmLogHostTable lists hosts which are to
+ receive syslog messages. This table also defines which
+ types and levels of messages to send.
+
+ Creating entries: Entries are created by setting a IP address
+ to biboAdmLogHostAddr.
+
+ Deleting entries: Entries are removed by setting the
+ appropriate biboAdmLogHostLevel field to 'delete'."
+ ::= { admin 13 }
+
+ biboAdmLogHostEntry OBJECT-TYPE
+ SYNTAX BiboAdmLogHostEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { biboAdmLogHostAddr }
+ ::= { biboAdmLogHostTable 1 }
+
+ BiboAdmLogHostEntry ::= SEQUENCE {
+ biboAdmLogHostAddr IpAddress,
+ biboAdmLogHostLevel INTEGER,
+ biboAdmLogHostFacility INTEGER,
+ biboAdmLogHostType INTEGER,
+ biboAdmLogHostTimestamp INTEGER,
+ biboAdmLogHostMethod INTEGER
+ }
+
+ biboAdmLogHostAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "Ip-Address where syslog messages are sent. If the
+ facility is set to memory or console, this field is
+ not used."
+ ::= { biboAdmLogHostEntry 1 }
+
+ biboAdmLogHostLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ emerg(1),
+ alert(2),
+ crit(3),
+ err(4),
+ warning(5),
+ notice(6),
+ info(7),
+ debug(8),
+ delete(9)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "Priorities lower or equal this level are sent to loghost.
+ The delete priority is used to discard the whole entry."
+ DEFVAL { info }
+ ::= { biboAdmLogHostEntry 2 }
+
+ biboAdmLogHostFacility OBJECT-TYPE
+ SYNTAX INTEGER {
+ local0(1),
+ local1(2),
+ local2(3),
+ local3(4),
+ local4(5),
+ local5(6),
+ local6(7),
+ local7(8)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "The facility used for the syslog messages being generated."
+ DEFVAL { local0 }
+ ::= { biboAdmLogHostEntry 4 }
+
+ biboAdmLogHostType OBJECT-TYPE
+ SYNTAX INTEGER {
+ system(1),
+ acct(2),
+ all(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "The subject of the messages that are to be generated. system
+ means all subjects except accounting, all means all subjects."
+ DEFVAL { all }
+ ::= { biboAdmLogHostEntry 5 }
+
+ biboAdmLogHostTimestamp OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ time(2),
+ all(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "This object describes the format of the timestamp.
+ none(1) = no timestamp,
+ time(2) = only time is printed,
+ all(3) = date and time is printed."
+ DEFVAL { none }
+ ::= { biboAdmLogHostEntry 6 }
+
+ biboAdmLogHostMethod OBJECT-TYPE
+ SYNTAX INTEGER {
+ udp(1),
+ tcp(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "This object provides protocol for sending syslog messages:
+ udp(1) = udp
+ tcp(2) = tcp
+ "
+ DEFVAL { udp }
+ ::= { biboAdmLogHostEntry 7 }
+
+-- Configuration
+
+ biboAdmConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BiboAdmConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+
+ DESCRIPTION
+ "The biboAdmConfigTable is used for assigning
+ parameters for managing configuration files.
+
+ Creating entries: Entries are added to this table by
+ assigning a value to the biboAdmConfigCmd object. (i.e., The
+ intermediate result of executing, cmd=save, creates an
+ entry to this table.).
+
+ Deleting entries: Entries can only be removed by the
+ system and is done only after the requested action has
+ been performed (i.e. Once the cmd=save action is
+ complete.)."
+ ::= { admin 14 }
+
+ biboAdmConfigEntry OBJECT-TYPE
+ SYNTAX BiboAdmConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { biboAdmConfigCmd }
+ ::= { biboAdmConfigTable 1 }
+
+ BiboAdmConfigEntry ::= SEQUENCE {
+ biboAdmConfigCmd INTEGER,
+ biboAdmConfigObject OBJECT IDENTIFIER,
+ biboAdmConfigPath DisplayString,
+ biboAdmConfigPathNew DisplayString,
+ biboAdmConfigHost IpAddress,
+ biboAdmConfigState INTEGER,
+ biboAdmConfigFile DisplayString,
+ biboAdmConfigTimeout INTEGER,
+ biboAdmConfigHostUrl DisplayString,
+ biboAdmConfigCertIndex INTEGER
+ }
+
+ biboAdmConfigDirTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BiboAdmConfigDirEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+
+ DESCRIPTION
+ "Configuration directory table. This table contains
+ all available configuration files in flash memory."
+ ::= { admin 15 }
+
+ biboAdmConfigDirEntry OBJECT-TYPE
+ SYNTAX BiboAdmConfigDirEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { biboAdmConfigDirName }
+ ::= { biboAdmConfigDirTable 1 }
+
+ BiboAdmConfigDirEntry ::= SEQUENCE {
+ biboAdmConfigDirName DisplayString,
+ biboAdmConfigDirCount INTEGER,
+ biboAdmConfigDirContent DisplayString,
+ biboAdmConfigDirSaveDate DisplayString
+ }
+
+ biboAdmConfigCmd OBJECT-TYPE
+ SYNTAX INTEGER {
+ save(1),
+ load(2),
+ put(3),
+ get(4),
+ state(5),
+ delete(6),
+ move(7),
+ copy(8),
+ reboot(9),
+ reorg(10),
+ unload(11),
+ put-all(12),
+ get-all(13),
+ load-keep-certs(14),
+ load-from-default(15)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Command for configuration handling. Possible values are :
+
+ save(1) = save configuration (to FLASH)
+ load(2) = load configuration (from FLASH)
+ put(3) = write configuration (via TFTP)
+ get(4) = read configuration (via TFTP)
+ state(5) = write complete configuration (via TFTP)
+ delete(6) = delete configuration (within FLASH)
+ move(7) = move configuration (within FLASH)
+ copy(8) = copy configuration (within FLASH)
+ reboot(9) = reboot the system
+ reorg(10) = reorganizes the flash
+ unload(11) = remove loaded configuration (from RAM)
+ put_all(12) = write configuration (via TFTP),
+ include not accessible variables
+ get_all(13) = read configuration (via TFTP),
+ including not accessible variables
+ load_keep_certs(14) = load configuration (from FLASH),
+ do not overwrite already loaded certificates
+ load-from-default(15) = load default configuration (from GENFILES)"
+
+ DEFVAL { save }
+ ::= { biboAdmConfigEntry 1 }
+
+ biboAdmConfigObject OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Table object id (OID) to save/load. If this field is
+ set, only this table is saved/loaded. Otherwise all tables
+ are saved/loaded."
+ ::= { biboAdmConfigEntry 2 }
+
+ biboAdmConfigPath OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "NAme of the configuration file in flash memory to save/load."
+ ::= { biboAdmConfigEntry 3 }
+
+ biboAdmConfigPathNew OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "New name of configuration file in flash memory to move/copy"
+ ::= { biboAdmConfigEntry 4 }
+
+ biboAdmConfigHost OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TFTP host's IP address to send/receive the file to/from.
+ The configuration is transfered directly from flash
+ memory (biboAdmConfigPath) to TFTP-file (biboAdmConfigFile)."
+ ::= { biboAdmConfigEntry 5 }
+
+ biboAdmConfigState OBJECT-TYPE
+ SYNTAX INTEGER { todo(1), running(2), done(3), error(4),
+ delayed(5), stopped(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state of this command (i.e., biboAdmConfigCmd).
+
+ todo(1) : the command will start soon
+ running(2) : the command is currently executing
+ done(3) : the command has successfully completed
+ error(4) : the command has failed (see biboAdmSyslogTable)
+ delayed(5) : the command is delayed due to given Timeout
+ stopped(6) : the command has stopped (Timeout set to -1)
+ "
+ DEFVAL { todo }
+ ::= { biboAdmConfigEntry 6 }
+
+ biboAdmConfigFile OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TFTP filename to read/write from/to the specified host.
+ The configuration file received is stored in flash memory
+ specified by biboAdmConfigPath.
+ The actual configuration is not changed."
+ ::= { biboAdmConfigEntry 7 }
+
+ biboAdmConfigTimeout OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set this value (default 0) to delay a new command for this
+ amount of seconds.
+ The value is counting down to show the remaining time
+ (State=delayed).
+ To stop a scheduled but delayed command set this value
+ to -1.
+ timeout = 0 cmd executed immediately (default)
+ timeout > 0 cmd executed in timeout seconds (counting down)
+ timeout < 0 cmd execution stopped (deleted)
+ "
+ DEFVAL { 0 }
+ ::= { biboAdmConfigEntry 8 }
+
+ biboAdmConfigHostUrl OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This is a host URL specifying the location to
+ retrieve or store the configuration file.
+ The last filename part must be missing and is given
+ in biboAdmConfigFile.
+ If this object is given biboAdmConfigHost is ignored.
+ format:
+ http://server/path/
+ tftp://server/path/
+ xmodem:[1k][@9600]
+ "
+ ::= { biboAdmConfigEntry 9 }
+
+ biboAdmConfigCertIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The index of the certificate to use (from the certTable).
+ Only used for biboAdmConfigCmd = get / get-all and for
+ use with biboAdmConfigHostUrl, of course.
+ If set to 0, no client certificate is used.
+
+ Default value is 0."
+ DEFVAL { 0 }
+ ::= { biboAdmConfigEntry 10 }
+---
+---
+---
+
+ biboAdmConfigDirName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Name of the configuration file in flash memory."
+ ::= { biboAdmConfigDirEntry 1 }
+
+ biboAdmConfigDirCount OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of tables saved in the file."
+ ::= { biboAdmConfigDirEntry 2 }
+
+ biboAdmConfigDirContent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description of directory's contents (e.g., <all> or a
+ series of table numbers)."
+ ::= { biboAdmConfigDirEntry 3 }
+
+ biboAdmConfigDirSaveDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Date when configuration was saved. It reflects value of
+ variable biboExtAdmConfigSaveDate which gets set when the
+ configuration is saved to flash.
+ This also means: if a configuration doesn't contain this
+ variable no date is available."
+ ::= { biboAdmConfigDirEntry 4 }
+
+
+-- Board Table
+
+ biboAdmBoardTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BiboAdmBoardEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The biboAdmBoardTable lists information about the
+ installed communications modules. This table is updated
+ after every system boot up.
+
+ Creating entries: Entries are created by the system
+ upon detecting the installed hardware.
+
+ Deleting entries: Entries are removed by the system
+ as a result of removed hardware."
+ ::= { admin 17 }
+
+ biboAdmBoardEntry OBJECT-TYPE
+ SYNTAX BiboAdmBoardEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { biboABrdSlot, biboABrdUnit }
+ ::= { biboAdmBoardTable 1 }
+
+ BiboAdmBoardEntry ::=
+ SEQUENCE {
+ biboABrdSlot INTEGER,
+ biboABrdType DisplayString,
+ biboABrdHWRelease DisplayString,
+ biboABrdFWRelease DisplayString,
+
+ biboABrdPartNo DisplayString,
+ biboABrdConnector INTEGER,
+ biboABrdUnit INTEGER,
+ biboABrdSerialNo DisplayString,
+
+ biboABrdCategory INTEGER
+ }
+
+ biboABrdSlot OBJECT-TYPE
+ SYNTAX INTEGER (0..31)
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The slot, or location of this module."
+ ::= { biboAdmBoardEntry 1 }
+
+ biboABrdType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The name of this module."
+ ::= { biboAdmBoardEntry 2 }
+
+ biboABrdHWRelease OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The hardware release of this module."
+ ::= { biboAdmBoardEntry 3 }
+
+ biboABrdFWRelease OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The firmware release of this module."
+ ::= { biboAdmBoardEntry 4 }
+
+ biboABrdPartNo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The part number of this module."
+ ::= { biboAdmBoardEntry 5 }
+
+ biboABrdConnector OBJECT-TYPE
+ SYNTAX INTEGER { auto(1), rj45(2), bnc(3), subd15(4),
+ rj45-10mbit-hdup(5), rj45-10mbit-fdup(6),
+ rj45-100mbit-hdup(7), rj45-100mbit-fdup(8) }
+ MAX-ACCESS read-write
+ STATUS obsolete
+
+ DESCRIPTION
+ "The type of connector used for this module. For
+ modules with more than one connector this value can be
+ changed/switched by setting this object. For example,
+ the CM-BNCTP module supports both twisted pair
+ (RJ45) and 10Base2 (BNC) connectors. If this object is set
+ to 'AUTO' then the BRICK will automatically detect
+ which connector type is being used."
+ ::= { biboAdmBoardEntry 6 }
+
+ biboABrdUnit OBJECT-TYPE
+ SYNTAX INTEGER (0..99)
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The logical unit number of this interface."
+ DEFVAL { 0 }
+ ::= { biboAdmBoardEntry 7 }
+
+ biboABrdSerialNo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The serial number of this module."
+ ::= { biboAdmBoardEntry 8 }
+
+ biboABrdCategory OBJECT-TYPE
+ SYNTAX INTEGER {
+ system-board(1),
+ ethernet(2),
+ isdn-bri(3),
+ isdn-pmx(4),
+ pots(5),
+ dsl(6),
+ wlan(7),
+ tty(8),
+ dsp(9),
+ usb(10),
+ crypt(11),
+ mobile(12)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "Board category. It can be one of the following:
+ system-board(1),
+ ethernet(2),
+ isdn-bri(3),
+ isdn-pmx(4),
+ pots(5),
+ dsl(6),
+ wlan(7),
+ tty(8),
+ dsp(9),
+ usb(10),
+ crypt(11),
+ mobile(12)
+
+ It advices users of which MIB table to look at when searching
+ for additional configuration informations."
+ ::= { biboAdmBoardEntry 9 }
+
+-- user defined traps
+
+ biboAdmUsrTrapTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BiboAdmUsrTrapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The biboAdmUsrTrapTable lists user-defined objects that
+ are used to create traps. These traps are sent locally, but
+ can also be sent to remote hosts using the
+ biboAdmTrapHostTable.
+
+ Creating entries: Entries are created by assigning the
+ biboATrpObj object a valid object identifier.
+
+ Deleting entries: Entries are removed by setting the
+ entry's biboATrpStatus object to 'delete'."
+ ::= { admin 18 }
+
+ biboAdmUsrTrapEntry OBJECT-TYPE
+ SYNTAX BiboAdmUsrTrapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { biboATrpObj }
+ ::= { biboAdmUsrTrapTable 1 }
+
+ BiboAdmUsrTrapEntry ::=
+ SEQUENCE {
+ biboATrpObj OBJECT IDENTIFIER,
+ biboATrpStatus INTEGER
+ }
+
+ biboATrpObj OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "The object identifier of an object to use. Each time this
+ object's value changes, a trap is created and sent. Either a
+ single leaf (single variable) or a table (of objects) can be
+ specified."
+ ::= { biboAdmUsrTrapEntry 1 }
+
+ biboATrpStatus OBJECT-TYPE
+ SYNTAX INTEGER { valid(1), delete(2) }
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "The status of this entry. Upon creation of a new entry,
+ this object's value is set to 'valid'."
+ DEFVAL { valid }
+ ::= { biboAdmUsrTrapEntry 2 }
+
+ biboAdmDomainName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Domain name."
+ DEFVAL { "" }
+ ::= { admin 19 }
+
+ biboAdmNameServer OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address of name server."
+ ::= { admin 20 }
+
+ biboAdmNameServ2 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address of second name server."
+ ::= { admin 21 }
+
+ biboAdmBridgeEnable OBJECT-TYPE
+ SYNTAX INTEGER { enabled(1), disabled (2) }
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "Sets bridging to enable / disable status."
+ DEFVAL { enabled }
+ ::= { admin 22 }
+
+ biboAdmCapiTcpPort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port for remote CAPI demon."
+ DEFVAL { 2662 }
+ ::= { admin 23 }
+
+ biboAdmTraceTcpPort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port for trace demon."
+ DEFVAL { 7000 }
+ ::= { admin 24 }
+
+ biboAdmRipUdpPort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "UDP port for RIP. Setting this object
+ to zero disables RIP."
+ DEFVAL { 520 }
+ ::= { admin 25 }
+
+ biboAdmSWVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the software release version. It's either identical to
+ biboAdmSWVersionOS or biboAdmSWVersionOEM."
+ ::= { admin 26 }
+
+ biboAdmTimeServer OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The IP address of the time server."
+ ::= { admin 27 }
+
+ biboAdmTimeOffset OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This is the time offset from GMT in seconds.
+ If the set value is in the range from -24 to 24,
+ it means hours, and is automatically converted
+ to seconds."
+ DEFVAL { 0 }
+ ::= { admin 28 }
+
+ biboAdmConsoleSyslog OBJECT-TYPE
+ SYNTAX INTEGER { enable(1), disable(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies whether to direct syslog messages to the
+ console."
+ DEFVAL { disable }
+ ::= { admin 29 }
+
+ biboAdmSyslogTableLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ emerg(1),
+ alert(2),
+ crit(3),
+ err(4),
+ warning(5),
+ notice(6),
+ info(7),
+ debug(8)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Specifies which message levels to post to the
+ biboAdmSyslogTable and the console, if applicable."
+ DEFVAL { info }
+ ::= { admin 30 }
+
+ biboAdmSystemId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object contains the system Identification String."
+ ::= { admin 31 }
+
+ biboAdmLicInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BiboAdmLicInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains an entry for each feature, that
+ can be activated by a license. The licenses have to
+ be entered in the biboAdmLicenseTable. This tabl
+ indicates the current state of the different licenses."
+ ::= { admin 32 }
+
+ biboAdmLicInfoEntry OBJECT-TYPE
+ SYNTAX BiboAdmLicInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { biboAdmLicInfoType, biboAdmLicInfoStatus }
+ ::= { biboAdmLicInfoTable 1 }
+
+ BiboAdmLicInfoEntry ::=
+ SEQUENCE {
+ biboAdmLicInfoType INTEGER,
+ biboAdmLicInfoStatus INTEGER,
+ biboAdmLicInfoId DisplayString,
+ biboAdmLicInfoSlot INTEGER,
+
+ biboAdmLicInfoMaxLic Counter32,
+ biboAdmLicInfoInUse Counter32,
+ biboAdmLicInfoHwSerial DisplayString,
+ biboAdmLicInfoUnit INTEGER,
+ biboAdmLicInfoLimit Counter32,
+ biboAdmLicInfoFree Counter32
+ }
+
+ biboAdmLicInfoType OBJECT-TYPE
+ SYNTAX INTEGER {
+ ip(1), capi(2), bridge(3), x25(4), ipx(5), stac(6),
+ frame-relay(7), tapi(8), ospf(9), extended-lan(10),
+ tunneling(11), taf(12), extended-wan(13), leased-line(14),
+ lcr(15),
+ app-power-phone(17), app-operator-desk(18),
+ app-voice-mail-server(19), app-accounting-tool(20),
+ app-intelligent-voice(21), app-6(22),
+ e25(29),
+ ipsec(33), ipseccb-ipxfer(34), bgp(35),
+ uefs(36), siplan(37), siptrunk(38), pim(39),
+ call-by-call(40), fax(41), sipout(42), brrp(43),
+ wlan-controller(44), terminal-option(45),
+ data-encr-accel(46), voice-mail-system(47), pptp(48),
+ ethernet(128), bri(129), g703(130), pri(131),
+ modem(132), g7032pri(133), slots(134), e3(135),
+ serial(136), shdsl(137), vdsl(138)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The licenseable feature."
+ ::= { biboAdmLicInfoEntry 1 }
+
+ biboAdmLicInfoStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ builtin(1), valid-license(2), invalid-license(3), no-license(4),
+ erase-internal(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the license."
+ ::= { biboAdmLicInfoEntry 2 }
+
+ biboAdmLicInfoId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The complete serial id string of the special license."
+ ::= { biboAdmLicInfoEntry 3 }
+
+ biboAdmLicInfoSlot OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "In case of a hardware license corresponding to a dedicated
+ module serial number, it is the slot number of the module."
+ ::= { biboAdmLicInfoEntry 4 }
+
+ biboAdmLicInfoMaxLic OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The max number of allowed chunks."
+ ::= { biboAdmLicInfoEntry 5 }
+
+ biboAdmLicInfoInUse OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The current number of chunks in use."
+ ::= { biboAdmLicInfoEntry 6 }
+
+ biboAdmLicInfoHwSerial OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The complete serial id string of the special license."
+ ::= { biboAdmLicInfoEntry 7 }
+
+ biboAdmLicInfoUnit OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "In case of a hardware license corresponding to a dedicated
+ module serial number, it is the unit number of the module."
+ ::= { biboAdmLicInfoEntry 8 }
+
+ biboAdmLicInfoLimit OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The maximum number of licenseable chunks."
+ ::= { biboAdmLicInfoEntry 9 }
+
+ biboAdmLicInfoFree OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The number of free default licences."
+ ::= { biboAdmLicInfoEntry 10 }
+
+
+
+
+ biboAdmBootpRelayServer OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object contains the destination IP address to
+ which BOOTP/DHCP request are forwarded by the
+ BIANCA/BRICK BOOTP relay agent.
+
+ If this entry is empty no BOOTP forwarding is done."
+ ::= { admin 33 }
+
+ biboAdmRadiusServer OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object contains the IP address of the RADIUS
+ server (remote dial in user service). If set to 0.0.0.0
+ RADIUS services are generally disabled (default).
+ The corresponding Radius password is configured in the
+ biboAdmRadiusSecret variable."
+ ::= { admin 34 }
+
+ biboAdmLocalPPPIdent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This is the local ID string used for PPP authentication
+ (PAP/CHAP). In pre4.3 versions the sysName has been used
+ as the local ID string. This is, for increased ease and
+ transparency of system configuration, no longer true."
+ DEFVAL { "" }
+ ::= { admin 35 }
+
+ biboAdmHttpTcpPort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port for the HTTP server. Default port is 80, 0 disables
+ the HTTP server."
+ DEFVAL { 80 }
+ ::= { admin 36 }
+
+ biboAdmTapiTcpPort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "TCP port for remote TAPI demon."
+ DEFVAL { 2663 }
+ ::= { admin 37 }
+
+ biboAdmTimeProtocol OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ time-udp(2),
+ time-tcp(3),
+ time-sntp(4),
+ isdn(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This field specifies from which source the bricks internal
+ clock is synchronised:
+ none(1) = no time synchronisation
+ time-udp(2) = UDP/TIME (RFC 868), from biboAdmTimeServer
+ time-tcp(3) = TCP/TIME (RFC 868), from biboAdmTimeServer
+ time-sntp(4) = SNTP (RFC 1769), from biboAdmTimeServer
+ isdn(5) = examines ISDN time, from controller stack 0"
+ DEFVAL { time-udp }
+ ::= { admin 38 }
+
+ biboAdmTimeUpdate OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This is the interval for timeserver requests (in seconds).
+ If the set value is in the range from -24 to 24,
+ it means hours, and is automatically converted
+ to seconds.
+ If the time comes from ISDN, the time is updated
+ with the next call after this interval."
+ DEFVAL { 24 }
+ ::= { admin 39 }
+
+
+ biboAdmWINS1 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP address of the WINS server (NetBIOS Name Server)."
+ ::= { admin 40 }
+
+
+ biboAdmWINS2 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP address of the alternate WINS server."
+ ::= { admin 41 }
+
+ admin-2 OBJECT IDENTIFIER
+ ::= { bibo 22 }
+
+-- Card Table
+
+ biboAdmCardTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BiboAdmCardEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The biboAdmCardTable lists installed cards."
+ ::= { admin 42 }
+
+ biboAdmCardEntry OBJECT-TYPE
+ SYNTAX BiboAdmCardEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { biboACrdSlot }
+ ::= { biboAdmCardTable 1 }
+
+ BiboAdmCardEntry ::=
+ SEQUENCE {
+ biboACrdSlot INTEGER,
+ biboACrdType DisplayString,
+ biboACrdState INTEGER,
+ biboACrdCpldVersion DisplayString,
+ biboACrdFpgaVersion DisplayString,
+ biboACrdTemp INTEGER,
+ biboACrdTempAlarmThreshold INTEGER,
+ biboACrdTempAlarmTrap INTEGER,
+ biboACrdAdmin INTEGER,
+ biboACrdTempAlarmThresholdCriticalLow INTEGER
+ }
+
+ biboACrdSlot OBJECT-TYPE
+ SYNTAX INTEGER (0..31)
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The slot, or location of this card."
+ ::= { biboAdmCardEntry 1 }
+
+ biboACrdType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The name of this card."
+ ::= { biboAdmCardEntry 2 }
+
+ biboACrdState OBJECT-TYPE
+ SYNTAX INTEGER { down(1), running(2), fail(3), stopped(4),
+ stopping(5), starting (6) }
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "State of the card."
+ DEFVAL { down }
+ ::= { biboAdmCardEntry 3 }
+
+ biboACrdCpldVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "Version of onboard CPLD."
+ ::= { biboAdmCardEntry 4 }
+
+ biboACrdFpgaVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "Version of loaded FPGA firmware."
+ ::= { biboAdmCardEntry 5 }
+
+ biboACrdTemp OBJECT-TYPE
+ SYNTAX INTEGER (0..250)
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "This variable shows the actual card temperature
+ in the unit Celsius."
+ ::= { biboAdmCardEntry 6 }
+
+ biboACrdTempAlarmThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..250)
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "Card temperature threshold."
+ ::= { biboAdmCardEntry 7 }
+
+ biboACrdTempAlarmTrap OBJECT-TYPE
+ SYNTAX INTEGER { normal(1), critical(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If the card temperature raises above the threshold,
+ a trap is generated every 60 seconds."
+ ::= { biboAdmCardEntry 8 }
+
+ biboACrdAdmin OBJECT-TYPE
+ SYNTAX INTEGER { up(1), down(2), reconfig(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Administrative manipulation of card state."
+ ::= { biboAdmCardEntry 9 }
+
+ biboACrdTempAlarmThresholdCriticalLow OBJECT-TYPE
+ SYNTAX INTEGER (0..250)
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "Lower Card temperature threshold to return state from critical
+ to normal. Mustn't exceed biboACrdTempAlarmThreshold!
+
+ When temperature reaches biboACrdTempAlarmThreshold state
+ changes to critical. This state persists until temperature
+ falls below biboACrdTempAlarmThreshUncriticalLow where state
+ changes back to normal."
+ ::= { biboAdmCardEntry 10 }
+
+
+ biboAdmTraps OBJECT IDENTIFIER ::= { admin 43 }
+
+ biboAdmTrapACrdTempCritical TRAP-TYPE
+ ENTERPRISE biboAdmTraps
+ VARIABLES {
+ sysDescr,
+ sysName,
+ biboACrdSlot,
+ biboACrdType,
+ biboACrdState,
+ biboACrdTemp,
+ biboACrdTempAlarmThreshold
+ }
+ DESCRIPTION "This trap signifies that the Card temperature raises
+ above the critical alarm-threshold"
+ ::= 1
+
+ biboAdmTrapACrdTempOk TRAP-TYPE
+ ENTERPRISE biboAdmTraps
+ VARIABLES {
+ sysDescr,
+ sysName,
+ biboACrdSlot,
+ biboACrdType,
+ biboACrdState,
+ biboACrdTemp,
+ biboACrdTempAlarmThreshold
+ }
+ DESCRIPTION "A normal Card temperature has been restored."
+ ::= 2
+
+ biboAdmTrapACrdDown TRAP-TYPE
+ ENTERPRISE biboAdmTraps
+ VARIABLES {
+ sysDescr,
+ sysName,
+ biboACrdSlot,
+ biboACrdType,
+ biboACrdState,
+ biboACrdTemp
+ }
+ DESCRIPTION "This trap signifies that the specified Card is down"
+ ::= 3
+
+ biboAdmTrapACrdRunning TRAP-TYPE
+ ENTERPRISE biboAdmTraps
+ VARIABLES {
+ sysDescr,
+ sysName,
+ biboACrdSlot,
+ biboACrdType,
+ biboACrdState,
+ biboACrdTemp
+ }
+ DESCRIPTION "This trap signifies that the specified Card
+ is up/running"
+ ::= 4
+
+ biboAdmTrapACrdFailed TRAP-TYPE
+ ENTERPRISE biboAdmTraps
+ VARIABLES {
+ sysDescr,
+ sysName,
+ biboACrdSlot,
+ biboACrdType,
+ biboACrdState,
+ biboACrdTemp
+ }
+ DESCRIPTION "This trap signifies that the specified Card
+ has failed"
+ ::= 5
+
+ biboAdmTrapACrdStopped TRAP-TYPE
+ ENTERPRISE biboAdmTraps
+ VARIABLES {
+ sysDescr,
+ sysName,
+ biboACrdSlot,
+ biboACrdType,
+ biboACrdState,
+ biboACrdTemp
+ }
+ DESCRIPTION "This trap signifies that the specified Card
+ is stopped"
+ ::= 6
+
+-- biboAdmSnmpLinkTrapEvent OBJECT-TYPE
+-- SYNTAX INTEGER { none(1),
+-- any(2),
+-- up(3),
+-- down(4)
+-- }
+-- MAX-ACCESS read-write
+-- STATUS current
+--
+-- DESCRIPTION
+-- "Defines the ifOperStatus transition(s) of an ifTable object
+-- that generates a SNMP linkUp/linkDown trap:
+--
+-- none : disable linkUp/linkDown trap generation.
+--
+-- any : enable bintec like trap generation.
+-- - entering the up state generates a up trap
+-- - any other state change generates a down trap
+--
+-- up : enable rfc1157 like trap generation.
+-- - entering the up state generates a up trap
+-- - leaving the up state generates a down trap
+--
+-- down : enable rfc2233 like trap generation.
+-- - leaving the down state generates a up trap
+-- - entering the down state generates a down trap
+--
+-- Seven parameters are sent in each linkUp/linkDown trap pdu:
+-- 1. ifEntry.ifIndex (mandatory for linkUp/Down traps)
+-- 2. ifEntry.ifDescr
+-- 3. ifEntry.ifType
+-- 4. ifEntry.ifAdminStatus
+-- 5. ifEntry.ifOperStatus
+-- 6. system.Description
+-- 7. system.Name"
+-- DEFVAL { up }
+-- ::= { admin 44 }
+
+ biboAdmExtendedBanner OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This is an additional banner message which is displayed
+ after the standard welcome message at boot time.
+ This message is typically used to display info regarding
+ a special configuration of the router."
+ DEFVAL { "" }
+ ::= { admin 45 }
+
+ biboAdmBootpRelayServ2 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object contains the second destination IP address
+ to which BOOTP/DHCP request are forwarded by the
+ BIANCA/BRICK BOOTP relay agent.
+
+ If this entry is empty no BOOTP forwarding is done."
+ ::= { admin 47 }
+
+ biboAdmTimedBootPolicy OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1), -- same behaviour as in normal operation
+ aggressive(2), -- send more frequent retries for 10 minutes
+ endless(3) -- same as aggressive, do not stop at all
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the frequency with which the timed
+ requests the time (using the specified time protocol)
+ after system startup until the first reply is received.
+ Possible values:
+ normal(1): -- 5 retries after 1, 2, 4, 8, 16 minutes
+ aggressive(2): -- retry 10 minutes with 1, 2, 4, 8, 10, 10, ...
+ seconds of timeout
+ endless(3): -- same as aggressive except there is no time
+ limit."
+ DEFVAL { endless }
+ ::= { admin 48 }
+
+ biboAdmAcctlogFormat OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "Specifies the format of accounting messages sent by
+ the syslog protocol. The format can consist of any order
+ of random strings, backslash escaped sequences like '\t','\n', etc.
+ or the following format tags:
+
+ Tag Meaning
+ %d Date the session opened; in DD.MM.YY format.
+ %t Time the session opened: in HH:MM:SS format
+ %a session age in seconds
+ %c protocol type
+ %i source IP address
+ %r source port
+ %f source interface index
+ %I destination IP address
+ %R destination port
+ %F destination interface index
+ %p outgoing packets
+ %o outgoing octets
+ %P incoming packets
+ %O incoming octets
+ %s message sequence counter
+ %% '%'
+
+ The format for accounting messages is per default:
+
+ 'INET: %d %t %a %c %i:%r/%f -> %I:%R/%F %p %o %P %O [%s]'
+
+ "
+ DEFVAL { "INET: %d %t %a %c %i:%r/%f -> %I:%R/%F %p %o %P %O [%s]" }
+ ::= { admin 49 }
+
+ biboAdmAcctlogMaxEntries OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "Maximum Number of accounting messages stored in memory."
+ DEFVAL { 20 }
+ ::= { admin 50 }
+
+ biboAdmAcctlogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BiboAdmAcctlogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The biboAdmAcctlogTable keeps track of accounting messages
+ received. The columns specify attributes for each message generated. As
+ this information only reports events on the system, all
+ fields are read-only.
+
+ Creating entries: Entries can only be created by the
+ system and are made each time a message for accounting is
+ generated.
+
+ Deleting entries: Entries are removed by the system
+ the messages are sent to the loghost."
+ ::= { admin 51 }
+
+ biboAdmAcctlogEntry OBJECT-TYPE
+ SYNTAX BiboAdmAcctlogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { biboAdmAcctlogLevel }
+ ::= { biboAdmAcctlogTable 1 }
+
+ BiboAdmAcctlogEntry ::=
+ SEQUENCE {
+ biboAdmAcctlogTimeStamp Date,
+ biboAdmAcctlogLevel INTEGER,
+ biboAdmAcctlogMessage DisplayString,
+ biboAdmAcctlogSubject INTEGER
+ }
+
+ biboAdmAcctlogTimeStamp OBJECT-TYPE
+ SYNTAX Date
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "Time message was generated."
+ ::= { biboAdmAcctlogEntry 1 }
+
+ biboAdmAcctlogLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ emerg(1),
+ alert(2),
+ crit(3),
+ err(4),
+ warning(5),
+ notice(6),
+ info(7),
+ debug(8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "Level of acct message."
+ DEFVAL { info }
+ ::= { biboAdmAcctlogEntry 2 }
+
+ biboAdmAcctlogMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The text of the acct message."
+ ::= { biboAdmAcctlogEntry 4 }
+
+ biboAdmAcctlogSubject OBJECT-TYPE
+ SYNTAX INTEGER {
+ acct(1),
+ isdn(2),
+ inet(3),
+ x25(4),
+ ipx(5),
+ capi(6),
+ ppp(7),
+ bridge(8),
+ config(9),
+ snmp(10),
+ x21(11),
+ token(12),
+ ether(13),
+ radius(14),
+ tapi(15),
+ ospf(16),
+ fr(17),
+ modem(18),
+ rip(19),
+ atm(20),
+ pabx(21),
+ ipsec(22),
+ tty(23),
+ bgp(24),
+ tacacs(25),
+ brrp(26),
+ mps(27),
+ voip(28),
+ tr069(29),
+ wlan(30),
+ usb(31),
+ http(32),
+ inet6(33),
+ wlc(34),
+ ldap(35),
+ osp(36),
+ wtp(37),
+ tremp(38),
+ presence(39)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "Subject of the acct message."
+ DEFVAL { acct }
+ ::= { biboAdmAcctlogEntry 5 }
+
+ biboAdmSyslogEntry OBJECT-TYPE
+ SYNTAX BiboAdmSyslogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { biboAdmSyslogTimeStamp, biboAdmSyslogLevel }
+ ::= { biboAdmSyslogTable 1 }
+
+ BiboAdmSyslogEntry ::=
+ SEQUENCE {
+ biboAdmSyslogTimeStamp Date,
+ biboAdmSyslogLevel INTEGER,
+ biboAdmSyslogMessage DisplayString,
+ biboAdmSyslogSubject INTEGER
+ }
+
+ biboAdmSyslogTimeStamp OBJECT-TYPE
+ SYNTAX Date
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "Time message was generated."
+ ::= { biboAdmSyslogEntry 1 }
+
+ biboAdmSyslogLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ emerg(1),
+ alert(2),
+ crit(3),
+ err(4),
+ warning(5),
+ notice(6),
+ info(7),
+ debug(8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "Level of syslog message."
+ DEFVAL { emerg }
+ ::= { biboAdmSyslogEntry 2 }
+
+ biboAdmSyslogMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "The text of the syslog message."
+ ::= { biboAdmSyslogEntry 4 }
+
+ biboAdmSyslogSubject OBJECT-TYPE
+ SYNTAX INTEGER {
+ acct(1),
+ isdn(2),
+ inet(3),
+ x25(4),
+ ipx(5),
+ capi(6),
+ ppp(7),
+ bridge(8),
+ config(9),
+ snmp(10),
+ x21(11),
+ token(12),
+ ether(13),
+ radius(14),
+ tapi(15),
+ ospf(16),
+ fr(17),
+ modem(18),
+ rip(19),
+ atm(20),
+ pabx(21),
+ ipsec(22),
+ tty(23),
+ bgp(24),
+ tacacs(25),
+ brrp(26),
+ mps(27),
+ voip(28),
+ tr069(29),
+ wlan(30),
+ usb(31),
+ http(32),
+ inet6(33),
+ wlc(34),
+ ldap(35),
+ osp(36),
+ wtp(37),
+ tremp(38),
+ presence(39)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+
+ DESCRIPTION
+ "Subject of the syslog message."
+ DEFVAL { acct }
+ ::= { biboAdmSyslogEntry 5 }
+
+
+ biboAdmTimeSource OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1), -- time has not been initialized yet
+ rtc(2), -- time has been initialized by real time clock
+ manual(3), -- time has been set manually
+ isdn(4), -- time has been set by ISDN
+ server(5), -- time has been received from a time server
+ gps(6) -- time has been received from GPS
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The source of the current system time."
+ DEFVAL { none }
+ ::= { admin 52 }
+
+ biboAdmIsdnTimeUpdate OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1), -- time retrieval over ISDN is enabled
+ disabled(2), -- time retrieval over ISDN is disabled
+ convert(3) -- convert setting in TimeProtocol
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies whether a time value which has been
+ retrieved via ISDN should be used to set the system time.
+ Note that the time retrieved via ISDN is ignored if the system
+ time has been set by a time server previously."
+ DEFVAL { convert }
+ ::= { admin 53 }
+
+ biboAdmSyslogTcpRetries OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+
+ DESCRIPTION
+ "Maximum number of attempts to connect a syslog server over TCP."
+ DEFVAL { 3 }
+ ::= { admin 55 }
+
+ biboAdmSWVersionOS OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the OS software release version as it was always found
+ in biboAdmSWVersion."
+ ::= { admin 56 }
+
+ biboAdmSWVersionOEM OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the OEM software release version.
+ Either there's a separate OEM version defined or this is
+ identical to biboAdmSWVersionOS."
+ ::= { admin 57 }
+
+ biboAdmStartMode OBJECT-TYPE
+ SYNTAX INTEGER { normal(1), service(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If service procedure is activated, mode is set to service,
+ otherwise mode is set to normal."
+ ::= { admin 58 }
+
+
+ extadmin OBJECT IDENTIFIER
+ ::= { admin-2 1 }
+
+ biboExtAdmMonAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP address of the host machine running the Activity
+ Monitor program. This program displays the information
+ about the current state of all interfaces.
+ Periodically UDP packets are send to this IP address,
+ to refresh the data automatically on the target host.
+ The value 255.255.255.255 represents the broadcast address
+ of the first LAN interface (e.g. 10.255.255.255), so
+ more than one Activity Monitor on different hosts can
+ receive the data."
+ DEFVAL { 'ffffffff'H }
+ ::= { extadmin 1 }
+
+ biboExtAdmMonPort OBJECT-TYPE
+ SYNTAX INTEGER (0 .. 65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "UDP port for the Activity Monitor protocol."
+ DEFVAL { 2107 }
+ ::= { extadmin 2 }
+
+ biboExtAdmMonType OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(1), physical(2), physical-virt(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This parameter configures the content of the Activity Monitor
+ packets, or disables it:
+ off : Activity Monitor disabled
+ physical : send only physical interfaces information
+ physical-virt: send physical and virtual interface
+ information."
+ DEFVAL { off }
+ ::= { extadmin 3 }
+
+ biboExtAdmMonUpdate OBJECT-TYPE
+ SYNTAX INTEGER (0 .. 60)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This is the time interval for the Activity Monitor
+ for sending packets (in seconds) to the specified IP address.
+ The value of 0 disables sending Activity Monitor packets."
+ DEFVAL { 5 }
+ ::= { extadmin 4 }
+
+ biboExtAdmProcRouted OBJECT-TYPE
+ SYNTAX INTEGER { enabled(1), disabled (2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "enabled: The routed process is running.
+ RIP and/or OSPF are available (subject to licenses).
+
+ This is the default behavior of the system.
+
+ Hints:
+
+ RIP may be enabled/disabled by 'biboAdmRipUdpPort'
+ OSPF may be enabled/disabled by 'ospfAdminStat'
+
+ RIP may be if-specific ena/disabled by 'ipExtIfRip*'
+ OSPF may be if-specific ena/disabled by 'ipExtIfOspf'
+
+ ... but a running routed process consumes CPU-Time
+ to keep in sync with interface/routing tables - even
+ if RIP and OSPF are disabled (global or if-specific).
+
+ disabled: The routed process is stopped.
+ RIP and/or OSPF are unavailable.
+
+ Hints:
+
+ A stopped routed process consumes no CPU-Time.
+
+ Set ipExtAdmProcRouted to 'disabled' is recommended
+ if both protocols (RIP and OSPF) not used in the
+ specific router environment.
+ "
+ DEFVAL { enabled }
+ ::= { extadmin 5 }
+
+ biboExtAdmProcWatchDog OBJECT-TYPE
+ SYNTAX INTEGER { enabled(1), disabled (2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "enabled: The watchd process is running.
+ up/down transitions on interfaces delivered by
+ various protocols like ping/ifOperStatus/VRRP
+ are processed by parsing a task table and slave
+ interfaces are switched up/down according to the
+ task definition.
+ disabled: The watchd process is stopped."
+ DEFVAL { disabled }
+ ::= { extadmin 7 }
+
+ biboExtAdmProcSSHd OBJECT-TYPE
+ SYNTAX INTEGER { enabled(1), disabled (2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "enabled: The sshd process is running.
+ disabled: The sshd process is stopped."
+ DEFVAL { enabled }
+ ::= { extadmin 8 }
+
+ biboExtAdmScheduleInterval OBJECT-TYPE
+ SYNTAX INTEGER (0 .. 65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This is the time interval in seconds for the Schedule
+ daemon watching any events (recommended value: 300).
+ The value 0 disables the scheduler.
+ Referring table: scheduleTable"
+ DEFVAL { 0 }
+ ::= { extadmin 9 }
+
+ biboExtAdmUpdatePath OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Default URL for automatic SW updates, e.g. http://server/path/
+ This setting is IGNORED if chkUpdSrvAdminOperURL is not empty.
+ Otherwise, related chkUpdSrv entry is allocated for it.
+ If URL does NOT end with '/' then it is considered being
+ complete and copied to related chkUpdSrvDownloadLink.
+ Otherwise, following parts are appended automatically.
+ '<sysname>[-<mode>]/<sysname>[-<mode>]-s_current'"
+ DEFVAL { "http://system-update.eu/" }
+ ::= { extadmin 10 }
+
+ biboExtAdmBackRtVerify OBJECT-TYPE
+ SYNTAX INTEGER { always(1), interface-dependent(2), never(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object activates an additional check for incoming
+ packets. If set to always (1), incoming packets are only
+ accepted if return packets sent back to their source IP
+ address would be sent over the same interface. This prevents
+ packets being passed from untrusted interfaces to this
+ interface. If set to interface-dependent (2), this check
+ will be performed only if enabled for the associated ingress
+ interface (see ipExtIfBackRtVerify). If set to never (2),
+ this check will be never performed, regardless wether enabled
+ or not for the associated interface."
+ DEFVAL { interface-dependent }
+ ::= { extadmin 11 }
+
+ biboExtAdmRerouteViaDefault OBJECT-TYPE
+ SYNTAX INTEGER { disabled(1), enabled(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object controls the behaviour of the routing algorithm
+ when a network route exists for routing a packet, but is
+ temporarily unusable because the status of the associated
+ interface prevents transmission. In such a case, the routing
+ algorithm tries to select an alternate route to allow the
+ packet to reach its destination. If set to disabled (1),
+ default routes are discarded during the search for a suitable
+ alternate route. If set to enabled (2), a default route may
+ be selected for rerouting provided it is the most appropriate
+ route available."
+ DEFVAL { disabled }
+ ::= { extadmin 12 }
+
+ biboExtAdmGUILanguage OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(3))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the language used within the graphical
+ user interface (currently new web based interface only).
+ Valid abbreviations (in principle) are defined in ISO 639-2."
+ DEFVAL { "eng" }
+ ::= { extadmin 13 }
+
+ biboExtAdmIpLogging OBJECT-TYPE
+ SYNTAX BITS { nat(0), tcppr(1), dns(2), ips(3), acl(4) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This bitfield enables logging of dedicated subsystems
+ within the INET subject:
+ nat : NAT
+ tcppr : TCP processing (MSS clamping, ...)
+ dns : DNS
+ ips : IP session management
+ acl : Local Services Access Control
+ ."
+ DEFVAL { { nat, tcppr, dns, ips, acl } }
+ ::= { extadmin 14 }
+
+ biboExtAdmRadiusNasId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "An administratively-assigned NAS identifier for this managed
+ node. If configured this variable is used for each RADIUS
+ request in order to set the associated NAS-IDENTIFIER RADIUS
+ attribute value."
+ ::= { extadmin 15 }
+
+ biboExtAdmConfigSaveDate OBJECT-TYPE
+ SYNTAX Date
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Timestamp when configuration gets/got saved (system local
+ time)."
+ DEFVAL { 0 }
+ ::= { extadmin 17 }
+
+ biboExtAdmSnmpShellPrompt OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines prompt of application SNMP shell.
+ A set of escape sequences is defined with escape character
+ being a backslash '\':
+ - 'e': gets replaced by escape character (0x1b)
+ - 'h': gets replaced by system name (i.e. host)
+ - 'T': can be used for MIB context replacements ...
+ %n -> current MIB table name
+ %# -> current MIB table number
+ %g -> current MIB group number
+ A longer string can be put within parentheses '(' ')'
+ causing the whole string to be left out if no context
+ is available instead of only the MIB variables.
+
+ Examples, assuming context MIB table 'system':
+ String Yields
+ ------------------------+------------------------
+ \T%n | 'system'
+ \T( MIB{%n/#%#/g:%g\)}) | ' MIB{system/#1/g:1}'
+ - 'l': gets replaced by log name (i.e. user, normally admin)
+ - 'd': can be used for date/time replacements with '%'
+ escaped replacements ...
+ %C -> century
+ %d -> day of month (01..31)
+ %D -> date in format 'MM/DD/YY'
+ %F -> date in format YYYY-MM-DD
+ %H -> hour (00..23)
+ %I -> hour (01..12)
+ %j -> day of year (1..366)
+ %k -> hour ( 0..23)
+ %l -> hour ( 1..12)
+ %m -> month (01..12)
+ %M -> minute (00..59)
+ %p -> AM/PM
+ %P -> am/pm
+ %R -> 24 hour time in format HH:MM
+ %s -> seconds sincs 1970-01-01 00:00:00 UTC
+ %S -> seconds (00..59)
+ %T -> 24 hour time in format HH:MM:SS
+ %u -> day of week (1..7)
+ %w -> day of week (0..6)
+ %y -> year (last two digits, 00..99)
+ %Y -> year
+ A longer string can be put within parentheses '(' ')'
+ to save repetitions of leading '\d' for every
+ replacement.
+ - 'u': gets replaced by system's uptime in format
+ [D ]HH:MM:SS
+
+ Default value is '\h:\t(%n)> '."
+ DEFVAL { "\h:\T(%n)> " }
+ ::= { extadmin 18 }
+
+ biboExtAdmMinArpLifeTime OBJECT-TYPE
+ SYNTAX INTEGER (0 .. 86400)
+ UNITS "s"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object defines the minimum lifetime (in seconds)
+ of ipNetToMediaTable entries."
+ DEFVAL { 0 }
+ ::= { extadmin 19 }
+
+ biboExtAdmInitialGUIView OBJECT-TYPE
+ SYNTAX INTEGER { full-access(1), user(2), initial-operation(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object controls the initial GUI behavior for admin login
+ for boxes with supports of 'GUI Views' and 'Initial Operation View' in GUI.
+ full-access: show the complete admin navigation.
+ user: show the user view
+ initial-operation: show the initial operation view.
+ If initial operation is not supported fall back to user view,
+ if user view is not supported fall back to full access."
+ DEFVAL { initial-operation }
+ ::= { extadmin 21 }
+
+
+-- Time Server Table
+
+ timeServerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TimeServerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains the list of time servers."
+ ::= { admin 54 }
+
+ timeServerEntry OBJECT-TYPE
+ SYNTAX TimeServerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This object contains a time server entry."
+ INDEX {
+ timeSrvPriority
+ }
+ ::= { timeServerTable 1 }
+
+ TimeServerEntry ::=
+ SEQUENCE {
+ timeSrvPriority INTEGER,
+ timeSrvProtocol INTEGER,
+ timeSrvAddress DisplayString
+ }
+
+ timeSrvPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..128)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The priority of the time server.
+ The time servers are queried in the order of ascending priority
+ value, i.e. 0 first, 1 second ... ."
+ ::= { timeServerEntry 1 }
+
+ timeSrvProtocol OBJECT-TYPE
+ SYNTAX INTEGER {
+ delete(1), -- delete this entry
+ time-udp (2), -- time protocol over udp
+ time-tcp (3), -- time protocol over tcp
+ sntp (4), -- sntp protocol
+ disabled (5) -- disabled
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The protocol used for the time server."
+ DEFVAL { sntp }
+ ::= { timeServerEntry 2 }
+
+ timeSrvAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP Address or DNS name of the time server. If a DNS name
+ is specified here, it is resolved on demand."
+ ::= { timeServerEntry 3 }
+
+-- End Time Server Table
+
+ biboAdmNTPServer OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2),
+ clientdepend(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field controls the NTP server. If it is set to
+ disabled(1) client requests will be ignored. Setting it
+ to enabled(2) on every client request a server answer
+ is transmitted. In clientdepend(3) mode only a answer to
+ a client request is sent if an external reference exists."
+ DEFVAL { disabled }
+ ::= { admin 59 }
+
+ biboAdmTimeZone OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the currently set timezone. The corresponding
+ timezone must exist in timeZoneTable."
+ ::= { admin 60 }
+
+ timeZoneTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TimeZoneEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains the list of availabe timezones."
+ ::= { admin 61 }
+
+ timeZoneEntry OBJECT-TYPE
+ SYNTAX TimeZoneEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This object contains a time zone entry."
+ INDEX {
+ timeZoneIndex
+ }
+ ::= { timeZoneTable 1 }
+
+ TimeZoneEntry ::=
+ SEQUENCE {
+ timeZoneIndex INTEGER,
+ timeZoneName DisplayString,
+ timeZoneAlias DisplayString,
+ timeZoneOffset INTEGER
+ }
+
+ timeZoneIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index in Timezone Table."
+ ::= { timeZoneEntry 1 }
+
+ timeZoneName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Name of a Timezone."
+ ::= { timeZoneEntry 2 }
+
+ timeZoneAlias OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The abbreviation of a timezone."
+ ::= { timeZoneEntry 3 }
+
+ timeZoneOffset OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Timezone offset from UTC in seconds. Note that this contains
+ no information about daylight saving for this timezone"
+ ::= { timeZoneEntry 4 }
+
+
+ ntpServerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NtpServerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of DHCP-client-learned NTP-servers, relevant only if
+ related administrative table timeServer is empty."
+ ::= { admin 64 }
+
+ ntpServerEntry OBJECT-TYPE
+ SYNTAX NtpServerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This object contains a time server entry."
+ INDEX { ntpServerPriority }
+ ::= { ntpServerTable 1 }
+
+ NtpServerEntry ::=
+ SEQUENCE {
+ ntpServerPriority INTEGER,
+ ntpServerAddress DisplayString
+ }
+
+ ntpServerPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..128)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Priority of NTP-server. Lower value means 'preferred'."
+ ::= { ntpServerEntry 1 }
+
+ ntpServerAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IP-address or FQDN of NTP-server."
+ ::= { ntpServerEntry 2 }
+
+ sysStat OBJECT IDENTIFIER
+ ::= { sys 500 }
+
+ sysStatBootConfig OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1), -- no config at all
+ bootfac(2), -- factory boot config
+ default(3), -- default config
+ boot(4) -- boot config from flash
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "After system boot this variable shows which configuration
+ was loaded:
+ none: no configuration whatsoever
+ bootfac: factory boot configuration
+ default: default configuration as provided by image
+ boot: configuration found in flash."
+ DEFVAL { none }
+ ::= { sysStat 1 }
+
+ sysStatFunctionState OBJECT-TYPE
+ SYNTAX INTEGER { on(1), off(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable contains the current function state, which is
+ toggeled by pressing the function button on the device."
+ ::= { sysStat 2 }
+
+ -- next variable is intentionally saved to indicate operation mode
+ -- a configuration was saved with
+ sysStatOperationMode OBJECT-TYPE
+ SYNTAX INTEGER { plain(0), mgw(1), pbx(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable defines the operation mode of the device
+ concerning telephony functionality.
+
+ If any voice functionality is integrated it can be either
+ mgw(1) for Media GateWay functionality of pbx(2) for a
+ full-fledged telephone system.
+
+ For systems w/o voice functionality the variable has value
+ plain(0)."
+ ::= { sysStat 3 }
+
+ sysStatConfigConvert OBJECT-TYPE
+ SYNTAX INTEGER {
+ idle(1),
+ start(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable handles the Configuration Conversion from
+ pbx to mgw (later may be mgw to pbx)
+ For systems w/o voice functionality the variable has value
+ plain(0)."
+ DEFVAL{ idle }
+ ::= { sysStat 4 }
+
+ sysStatConfigConvertState OBJECT-TYPE
+ SYNTAX INTEGER {
+ idle(1),
+ progress(2),
+ done(3),
+ failed(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable handles the Configuration Conversion state
+
+ idle - No conversion in progress
+ progress - conversion in progress
+ done - conversion done
+ failed - conversion not possible
+
+ The value is set to progress during tne coversion progress.
+ On errer e.g configuration parameters already exists the
+ State is set to failed otherwise the State is set to idle
+ on success."
+ DEFVAL{ idle }
+ ::= { sysStat 5 }
+
+
+
+-- Trace buffers
+
+ traceBuffers OBJECT IDENTIFIER ::= { admin 65 }
+
+ -- administrative section
+ trcBufAdmin OBJECT IDENTIFIER ::= { traceBuffers 1 }
+
+ trcBufTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TrcBufEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains the list trace buffers."
+ ::= { trcBufAdmin 1 }
+
+ trcBufEntry OBJECT-TYPE
+ SYNTAX TrcBufEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This object contains a trace buffer entry."
+ INDEX {
+ trcBufIndex
+ }
+ ::= { trcBufTable 1 }
+
+ TrcBufEntry ::=
+ SEQUENCE {
+ trcBufIndex INTEGER,
+ trcBufDevice DisplayString,
+ trcBufMode INTEGER,
+ trcBufDataMode INTEGER,
+ trcBufSize INTEGER,
+ trcBufDataSize INTEGER,
+ trcBufDate INTEGER,
+ trcBufDescr DisplayString,
+ trcBufID Unsigned32,
+ trcBufOperation INTEGER
+ }
+
+ trcBufIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Unique Index of the trace buffer"
+ ::= { trcBufEntry 1 }
+
+ trcBufDevice OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The device representing this trace buffer"
+ ::= { trcBufEntry 2 }
+
+ trcBufMode OBJECT-TYPE
+ SYNTAX INTEGER { single-shot(1), continuous(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates operation mode of trace buffer:
+ single-shot: just fill buffer up to maximum size
+ continuous: ring buffer mode
+
+ In single-shot mode every write attempt that would exceed
+ buffer limits, causes the buffer to get closed for writing
+ and the write attempt to fail (as any further attempts will).
+
+ In continuous mode the buffer is filled up to the maximum size,
+ and overwrite older data as new data gets written.
+
+ Variable is meaningless as long as variable trcBufOperation
+ is set to unused."
+ ::= { trcBufEntry 3 }
+
+ trcBufDataMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ bytestream(1),
+ message(2),
+ message-per-session(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates how trace buffer treats data written to it:
+
+ In bytestream mode no structure is imposed on written data,
+ buffer will get completely filled up if enough data is written.
+ Data overwrite is done byte-by-byte.
+
+ Mode message keeps the data structure in messages as passed
+ down to the trace buffer and allows for reading them back in
+ same portions as written.
+
+ Mode message-per-session treats any data written to trace
+ buffer between opening and closing it as one message.
+
+ Variable is meaningless as long as variable trcBufOperation
+ is set to unused.
+
+ NOTE: modes message and message-per-session only reflect the
+ last state; it depends on the application(s) writing to the
+ trace buffer in which mode it is used, so this variable can
+ toggle between these two states over time."
+ ::= { trcBufEntry 4 }
+
+ trcBufSize OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum size of the trace buffer"
+ ::= { trcBufEntry 5 }
+
+ trcBufDataSize OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current data size of the trace buffer"
+ ::= { trcBufEntry 6 }
+
+ trcBufDate OBJECT-TYPE
+ SYNTAX Date
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time and date of the buffer creation"
+ ::= { trcBufEntry 7 }
+
+ trcBufDescr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Optional descriptive information of the buffer's purpose."
+ DEFVAL { "" }
+ ::= { trcBufEntry 8 }
+
+ trcBufID OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Optional identificator for the buffer."
+ DEFVAL { "" }
+ ::= { trcBufEntry 9 }
+
+ trcBufOperation OBJECT-TYPE
+ SYNTAX INTEGER {
+ unused(1),
+ idle(2),
+ read(3),
+ write(4),
+ read-write(5),
+ closed(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current status of the trace buffer:
+ unused: Device is free to be used
+ idle : Device is parameterized but not open
+ read : Device is open for reading
+ write: Device is open for writing
+ read-write: Device is open for reading and writing
+ full: No more writing to buffer possible
+
+ Value read-write would normally refer to two processes.
+ Value full indicates that no more data can be written to
+ buffer; it will remain unchanged until it gets deleted."
+ DEFVAL { unused }
+ ::= { trcBufEntry 10 }
+
+
+ trcBufOper OBJECT IDENTIFIER ::= { traceBuffers 2 }
+
+ trcBufStatNBufs OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of trace buffers supported by running firmware."
+ ::= { trcBufOper 1 }
+
+
+ trcBufStat OBJECT IDENTIFIER ::= { traceBuffers 3 }
+
+ trcBufStatNUnused OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of trace buffers currently available to store data."
+ ::= { trcBufStat 1 }
+
+ trcBufStatNOpen OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of trace buffers currently available for appending
+ data."
+ ::= { trcBufStat 2 }
+
+ trcBufStatNFull OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of trace buffers currently available for reading data
+ only (i.e. in state 'full')."
+ ::= { trcBufStat 3 }
+
+-- End Trace Buffers
+
+-- Begin automatic update check sechedule
+
+ chkUpdSrv OBJECT IDENTIFIER ::= { extadmin 22 }
+
+ chkUpdSrvAdmin OBJECT IDENTIFIER
+ ::= { chkUpdSrv 1 }
+
+ chkUpdSrvAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ ondemand(2),
+ periodic(3),
+ checknow(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Tells when to fetch/process the XML-file-contents pointed at
+ by chkUpdSrvAdminOperURL (if not empty string).
+ disabled: Clear chkUpdSrvAdminOperURL and supress further
+ fetch-attempts.
+ ondemand: Fetch at system-start and at every change of
+ chkUpdSrvAdminOperURL (unless empty string).
+ periodic: In addition to 'ondemand', fetch also periodically
+ with specified chkUpdSrvAdminInterval.
+ checknow: Fetch now and switch-back AdminStatus to previous
+ value (i.e. to disabled, ondemand, periodic).
+ "
+ DEFVAL { periodic }
+ ::= { chkUpdSrvAdmin 1 }
+
+ chkUpdSrvAdminInterval OBJECT-TYPE
+ SYNTAX INTEGER (1..8191)
+ UNITS "h"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Period in hours for checking for available updates.
+ Default value is once a week (7 * 24 = 168 hours).
+ Ignored if chkUpdSrvAdminStatus is NOT periodic.
+ "
+ DEFVAL { 168 }
+ ::= { chkUpdSrvAdmin 2 }
+
+ chkUpdSrvAdminURL OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Sets location of the XML description file, UNLESS value is set
+ already at compile-time (see chkUpdSrvAdminOperURL).
+ "
+ ::= { chkUpdSrvAdmin 3 }
+
+ chkUpdSrvAdminOperURL OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Shows location of the XML description file, coming from either
+ chkUpdSrvAdminURL or fixed compile-time-URL, or forced to empty
+ string if chkUpdSrvAdminStatus is disabled.
+ If resulting string is empty then chkUpdSrvTable is filled for
+ biboExtAdmUpdatePath instead, unless also empty.
+ "
+ ::= { chkUpdSrvAdmin 4 }
+
+ chkUpdSrvAdminDefaultDigestType OBJECT-TYPE
+ SYNTAX INTEGER {
+ crc32(1),
+ sha256(2),
+ signature(3),
+ none(16)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Default digest-checking-method (if not specified in XML-file)
+ "
+ DEFVAL {sha256 }
+ ::= { chkUpdSrvAdmin 5 }
+
+ chkUpdSrvAdminOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ idle(2),
+ checking(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current activity and state.
+ "
+ DEFVAL { idle }
+ ::= { chkUpdSrvAdmin 6 }
+
+ chkUpdSrvAdminLastSuccessfulCheckTime OBJECT-TYPE
+ SYNTAX Date
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If not 0, tells when chkUpdSrvTable was last updated
+ successfully for contents coming from either
+ chkUpdSrvAdminOperURL or biboExtAdmUpdatePath.
+ Is reset to 0 whenever chkUpdSrvAdminOperURL changes.
+ "
+ ::= { chkUpdSrvAdmin 7 }
+
+ chkUpdSrvAdminLastFailedCheckTime OBJECT-TYPE
+ SYNTAX Date
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If not 0, tells time of last unsuccessful update-attempt.
+ If bigger than chkUpdSrvAdminLastSuccessfulCheckTime then
+ retries are scheduled (see chkUpdSrvAdminLastFailedTries).
+ Is reset to 0 whenever chkUpdSrvAdminOperURL changes.
+ "
+ ::= { chkUpdSrvAdmin 8 }
+
+ chkUpdSrvAdminLastFailedCheckInfo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Display-status of last unsuccessful update-attempt.
+ (Not updated for successful checks.)
+ Is flushed to empty whenever chkUpdSrvAdminOperURL changes.
+ "
+ DEFVAL { "" }
+ ::= { chkUpdSrvAdmin 9 }
+
+ chkUpdSrvAdminActiveProductClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Currently active product-class.
+ "
+ ::= { chkUpdSrvAdmin 10 }
+
+ chkUpdSrvAdminAlternativeProductClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Alternative product-class (empty if unknown).
+ "
+ ::= { chkUpdSrvAdmin 11 }
+
+ chkUpdSrvAdminLastFailedTries OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If not 0, tells that retries are scheduled for latest failed
+ update-check, and how many tries have been done yet (see also
+ chkUpdSrvAdminLastFailedCheckTime for related timestamp).
+ Is reset to 0 whenever update-check succeeds or restarts (e.g.
+ due to changed chkUpdSrvAdminOperURL).
+ "
+ ::= { chkUpdSrvAdmin 12 }
+
+ chkUpdSrvTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ChkUpdSrvEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of available update-files. When update-command is called
+ with dummy-URL 'http:', it looks for a matching default-entry
+ in this table to get a proper chkUpdSrvDownloadLink.
+ "
+ ::= { chkUpdSrv 2 }
+
+ chkUpdSrvEntry OBJECT-TYPE
+ SYNTAX ChkUpdSrvEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Detailed info per listed update-file.
+ "
+ INDEX {
+ chkUpdSrvIndex
+ }
+ ::= { chkUpdSrvTable 1 }
+
+ ChkUpdSrvEntry ::=
+ SEQUENCE {
+ chkUpdSrvIndex INTEGER,
+ chkUpdSrvProductClass DisplayString,
+ chkUpdSrvFileType INTEGER,
+ chkUpdSrvFileDescr DisplayString,
+ chkUpdSrvFileVersion DisplayString,
+ chkUpdSrvFileDigestType INTEGER,
+ chkUpdSrvFileDigestValue DisplayString,
+ chkUpdSrvDownloadLink DisplayString,
+ chkUpdSrvRelNoteLink DisplayString,
+ chkUpdSrvFileUpdatable INTEGER
+ }
+
+ chkUpdSrvIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Unique identification of the entry.
+ "
+ ::= { chkUpdSrvEntry 1 }
+
+ chkUpdSrvProductClass OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Product-class for file.
+ "
+ ::= { chkUpdSrvEntry 2 }
+
+ chkUpdSrvFileType OBJECT-TYPE
+ SYNTAX INTEGER {
+ blup(1),
+ boss(2),
+ logic(3),
+ bootmon(4),
+ adsl(5),
+ vdsl(6),
+ gphy(7),
+ systelarchive(20),
+ voicemailarchive(21),
+ guixlation(30),
+ thirdparty(50)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Type of file.
+ "
+ DEFVAL { blup }
+ ::= { chkUpdSrvEntry 3 }
+
+ chkUpdSrvFileDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Additional file-description,
+ used for language and third party files.
+ "
+ ::= { chkUpdSrvEntry 4 }
+
+ chkUpdSrvFileVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Version of file (empty if unknown).
+ "
+ ::= { chkUpdSrvEntry 5 }
+
+ chkUpdSrvFileDigestType OBJECT-TYPE
+ SYNTAX INTEGER {
+ crc32(1),
+ sha256(2),
+ signature(3),
+ none(16)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Method to be used for digest-checking
+ "
+ DEFVAL {sha256 }
+ ::= { chkUpdSrvEntry 6 }
+
+ chkUpdSrvFileDigestValue OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Hash/signature for this file, depending on digest-type.
+ "
+ ::= { chkUpdSrvEntry 7 }
+
+ chkUpdSrvDownloadLink OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "URL for downloading this file.
+ "
+ ::= { chkUpdSrvEntry 8 }
+
+ chkUpdSrvRelNoteLink OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "URL for downloading release-notes (if any) for this file.
+ "
+ DEFVAL { "" }
+ ::= { chkUpdSrvEntry 9 }
+
+ chkUpdSrvFileUpdatable OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(1),
+ true(2),
+ unknown(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Tells if system can be updated with this file.
+ false: Update will not work or have no effect
+ true: Update will have effect
+ unknown: No info available (e.g. unknown file-version)
+ "
+ DEFVAL { unknown }
+ ::= { chkUpdSrvEntry 10 }
+
+END -- of BIANCA-BRICK definitions
|