summaryrefslogtreecommitdiff
path: root/MIBS/ciena/CIENA-WS-NOTIFICATION-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/ciena/CIENA-WS-NOTIFICATION-MIB')
-rw-r--r--MIBS/ciena/CIENA-WS-NOTIFICATION-MIB652
1 files changed, 652 insertions, 0 deletions
diff --git a/MIBS/ciena/CIENA-WS-NOTIFICATION-MIB b/MIBS/ciena/CIENA-WS-NOTIFICATION-MIB
new file mode 100644
index 0000000..da118a5
--- /dev/null
+++ b/MIBS/ciena/CIENA-WS-NOTIFICATION-MIB
@@ -0,0 +1,652 @@
+--
+-- CIENA-WS-NOTIFICATION-MIB.my
+--
+
+CIENA-WS-NOTIFICATION-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ Unsigned32, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, OBJECT-IDENTITY
+ FROM SNMPv2-SMI
+ cienaWsNotifications
+ FROM CIENA-WS-MIB
+ TEXTUAL-CONVENTION
+ FROM SNMPv2-TC;
+
+cienaWsNotificationMIB MODULE-IDENTITY
+ LAST-UPDATED "201801150000Z"
+ ORGANIZATION "Ciena Corporation"
+ CONTACT-INFO
+ "Web URL: http://www.ciena.com/
+Postal: 7035 Ridge Road
+ Hanover, Maryland 21076
+ U.S.A.
+Phone: +1 800-921-1144
+Fax: +1 410-694-5750"
+ DESCRIPTION
+ "Notification definitions for Waveserver. Contains alarm notifications and link
+state defects."
+ REVISION "201801150000Z"
+ DESCRIPTION "Updates wsAlarmNotificationActiveStatus from TruthValue to include
+ active(1), inactive(2), and intermittent(3) states"
+ REVISION "201611140000Z"
+ DESCRIPTION "Added MODULE-IDENTITY statements."
+ ::= { cienaWsNotifications 3 }
+
+-- Textual conventions
+DisplayString32 ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "32t"
+ STATUS current
+ DESCRIPTION
+ "A UTF-8 string with a max length of 32 characters"
+ SYNTAX OCTET STRING(SIZE(1..32))
+
+
+-- Alarm Notifications
+
+wsAlarmNotification NOTIFICATION-TYPE
+ OBJECTS {
+ wsAlarmNotificationSiteId,
+ wsAlarmNotificationGroupId,
+ wsAlarmNotificationMemberId,
+ wsAlarmNotificationInstanceId,
+ wsAlarmNotificationDateAndTime,
+ wsAlarmNotificationTableId,
+ wsAlarmNotificationSeverity,
+ wsAlarmNotificationInstance,
+ wsAlarmNotificationDescription,
+ wsAlarmNotificationActiveStatus,
+ wsAlarmNotificationEntityType
+ }
+ STATUS current
+ DESCRIPTION
+ "Ciena Wavesever notification for an alarm raising or clearing"
+ ::= { cienaWsNotifications 11 }
+
+wsAlarmNotificationSiteId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The system Site ID."
+ ::= { wsAlarmNotification 1 }
+
+wsAlarmNotificationGroupId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The system Group ID."
+ ::= { wsAlarmNotification 2 }
+
+wsAlarmNotificationMemberId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The system Member ID."
+ ::= { wsAlarmNotification 3 }
+
+wsAlarmNotificationInstanceId OBJECT-TYPE
+ SYNTAX Unsigned32(1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm Instance ID."
+ ::= { wsAlarmNotification 4 }
+
+wsAlarmNotificationDateAndTime OBJECT-TYPE
+ SYNTAX DisplayString32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The local date and time when alarm was raised."
+ ::= { wsAlarmNotification 5 }
+
+wsAlarmNotificationTableId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm table ID."
+ ::= { wsAlarmNotification 6 }
+
+wsAlarmNotificationSeverity OBJECT-TYPE
+ SYNTAX INTEGER {
+ cleared(1),
+ critical(3),
+ major(4),
+ minor(5),
+ warning(6),
+ info(8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm severity."
+ ::= { wsAlarmNotification 7 }
+
+wsAlarmNotificationInstance OBJECT-TYPE
+ SYNTAX DisplayString32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object instance the alarm is raised against."
+ ::= { wsAlarmNotification 8 }
+
+wsAlarmNotificationDescription OBJECT-TYPE
+ SYNTAX DisplayString32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm description."
+ ::= { wsAlarmNotification 9 }
+
+wsAlarmNotificationActiveStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ active(1),
+ inactive(2),
+ intermittent(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm active status."
+ ::= { wsAlarmNotification 10 }
+
+ -- Port Type
+wsAlarmNotificationEntityType OBJECT-TYPE
+ SYNTAX INTEGER {
+ notApplicable(0),
+ other(1),
+ clientPort(2),
+ linePort(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm source entity type if applicable."
+ ::= { wsAlarmNotification 11 }
+
+-- Link state notifications
+-- The following notification communicates the state of a link. This includes
+-- detailed information about the current health of the link.
+wsLinkStateAlarmNotification NOTIFICATION-TYPE
+ OBJECTS {
+ wsLinkStateAlarmNotificationSiteId,
+ wsLinkStateAlarmNotificationGroupId,
+ wsLinkStateAlarmNotificationMemberId,
+ wsLinkStateAlarmNotificationInstanceId,
+ wsLinkStateAlarmNotificationDateAndTime,
+ wsLinkStateAlarmNotificationSeverity,
+ wsLinkStateAlarmNotificationInstance,
+ wsLinkStateAlarmNotificationDescription,
+ wsLinkStateAlarmNotificationPtpRxLos,
+ wsLinkStateAlarmNotificationPtpRxLol,
+ wsLinkStateAlarmNotificationPtpTxLos,
+ wsLinkStateAlarmNotificationPtpTxLol,
+ wsLinkStateAlarmNotificationEthFecLossSync,
+ wsLinkStateAlarmNotificationEthEBer,
+ wsLinkStateAlarmNotificationEthRsLf,
+ wsLinkStateAlarmNotificationEthRsRf,
+ wsLinkStateAlarmNotificationEthPcsLobl,
+ wsLinkStateAlarmNotificationEthPcsLoam,
+ wsLinkStateAlarmNotificationEthPcsLol,
+ wsLinkStateAlarmNotificationEthRsLinkDown,
+ wsLinkStateAlarmNotificationOtuLoc,
+ wsLinkStateAlarmNotificationOtuFreqOor,
+ wsLinkStateAlarmNotificationOtuLof,
+ wsLinkStateAlarmNotificationOtuPreFecSf,
+ wsLinkStateAlarmNotificationOtuPreFecSd,
+ wsLinkStateAlarmNotificationOtuLom,
+ wsLinkStateAlarmNotificationOtuBdi,
+ wsLinkStateAlarmNotificationOtuTtiMismatch,
+ wsLinkStateAlarmNotificationOduOci,
+ wsLinkStateAlarmNotificationOduAis,
+ wsLinkStateAlarmNotificationOduLck,
+ wsLinkStateAlarmNotificationOduSf,
+ wsLinkStateAlarmNotificationOduSd,
+ wsLinkStateAlarmNotificationOduTtiMismatch,
+ wsLinkStateAlarmNotificationOduBdi,
+ wsLinkStateAlarmNotificationOduPtiMismatch,
+ wsLinkStateAlarmNotificationOduFeClientSf,
+ wsLinkStateAlarmNotificationOduSkewOor,
+ wsLinkStateAlarmNotificationEntityType
+ }
+ STATUS current
+ DESCRIPTION
+ "Ciena Waveserver notification for line faults."
+ ::= { cienaWsNotifications 12 }
+
+wsLinkStateAlarmNotificationSiteId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The line fault site ID."
+ ::= { wsLinkStateAlarmNotification 1 }
+
+wsLinkStateAlarmNotificationGroupId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The system Group ID."
+ ::= { wsLinkStateAlarmNotification 2 }
+
+wsLinkStateAlarmNotificationMemberId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The system Member ID."
+ ::= { wsLinkStateAlarmNotification 3 }
+
+wsLinkStateAlarmNotificationInstanceId OBJECT-TYPE
+ SYNTAX Unsigned32(1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The line fault instance ID."
+ ::= { wsLinkStateAlarmNotification 4 }
+
+wsLinkStateAlarmNotificationDateAndTime OBJECT-TYPE
+ SYNTAX DisplayString32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The local date and time when alarm was raised."
+ ::= { wsLinkStateAlarmNotification 5 }
+
+wsLinkStateAlarmNotificationSeverity OBJECT-TYPE
+ SYNTAX INTEGER {
+ cleared(1),
+ critical(3),
+ major(4),
+ minor(5),
+ warning(6),
+ info(8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm severity."
+ ::= { wsLinkStateAlarmNotification 7 }
+
+wsLinkStateAlarmNotificationInstance OBJECT-TYPE
+ SYNTAX DisplayString32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object instance the alarm is raised against."
+ ::= { wsLinkStateAlarmNotification 8 }
+
+wsLinkStateAlarmNotificationDescription OBJECT-TYPE
+ SYNTAX DisplayString32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm description."
+ ::= { wsLinkStateAlarmNotification 9 }
+
+
+ -- PTP
+wsLinkStateAlarmNotificationPtpDefects OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Defects related to the physical termination point."
+ ::= { wsLinkStateAlarmNotification 10 }
+
+
+wsLinkStateAlarmNotificationPtpRxLos OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PTP alarms for the link."
+ ::= { wsLinkStateAlarmNotificationPtpDefects 1 }
+
+wsLinkStateAlarmNotificationPtpRxLol OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PTP alarms for the link."
+ ::= { wsLinkStateAlarmNotificationPtpDefects 2 }
+
+wsLinkStateAlarmNotificationPtpTxLos OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PTP alarms for the link."
+ ::= { wsLinkStateAlarmNotificationPtpDefects 3 }
+
+wsLinkStateAlarmNotificationPtpTxLol OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "PTP alarms for the link."
+ ::= { wsLinkStateAlarmNotificationPtpDefects 4 }
+
+-- Ethernet alarms
+wsLinkStateAlarmNotificationEthDefects OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "Ethernet defects."
+ ::= { wsLinkStateAlarmNotification 11 }
+
+wsLinkStateAlarmNotificationEthPcsHighBer OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet PCS high bit error rate."
+ ::= { wsLinkStateAlarmNotificationEthDefects 1 }
+
+wsLinkStateAlarmNotificationEthPcsLoam OBJECT-TYPE
+ SYNTAX INTEGER { inactive(0), active(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet PCS loss of alignment marker."
+ ::= { wsLinkStateAlarmNotificationEthDefects 2 }
+
+wsLinkStateAlarmNotificationEthPcsLobl OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet PCS loss of block lock."
+ ::= { wsLinkStateAlarmNotificationEthDefects 3 }
+
+wsLinkStateAlarmNotificationEthRsLinkDown OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet RS link down."
+ ::= { wsLinkStateAlarmNotificationEthDefects 4 }
+
+wsLinkStateAlarmNotificationEthRsLf OBJECT-TYPE
+ SYNTAX INTEGER { inactive(0), active(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet RS local fault."
+ ::= { wsLinkStateAlarmNotificationEthDefects 5 }
+
+wsLinkStateAlarmNotificationEthRsRf OBJECT-TYPE
+ SYNTAX INTEGER { inactive(0), active(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet RS remote fault."
+ ::= { wsLinkStateAlarmNotificationEthDefects 6 }
+
+wsLinkStateAlarmNotificationEthFecLossSync OBJECT-TYPE
+ SYNTAX INTEGER { inactive(0), active(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet FEC loss of alignment marker."
+ ::= { wsLinkStateAlarmNotificationEthDefects 7 }
+
+wsLinkStateAlarmNotificationEthPmaSool OBJECT-TYPE
+ SYNTAX INTEGER { inactive(0), active(1) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ethernet PMA serdes out of lock."
+ ::= { wsLinkStateAlarmNotificationEthDefects 8 }
+
+
+-- OTU Alarms
+
+wsLinkStateAlarmNotificationOtuDefects OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "OTU layer defects."
+ ::= { wsLinkStateAlarmNotification 12 }
+
+
+wsLinkStateAlarmNotificationOtuLoc OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "OTU loss of clock."
+ ::= { wsLinkStateAlarmNotificationOtuDefects 1}
+
+wsLinkStateAlarmNotificationOtuFreqOor OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "OTU frequency out of range."
+ ::= { wsLinkStateAlarmNotificationOtuDefects 2 }
+
+wsLinkStateAlarmNotificationOtuLof OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "OTU loss of frame."
+ ::= { wsLinkStateAlarmNotificationOtuDefects 3 }
+
+wsLinkStateAlarmNotificationOtuPreFecSf OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "OTU pre-FEC signal fail."
+ ::= { wsLinkStateAlarmNotificationOtuDefects 4 }
+
+wsLinkStateAlarmNotificationOtuPreFecSd OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "OTU pre-FEC signal degrade."
+ ::= { wsLinkStateAlarmNotificationOtuDefects 5 }
+
+wsLinkStateAlarmNotificationOtuLom OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "OTU loss of multi-frame."
+ ::= { wsLinkStateAlarmNotificationOtuDefects 6 }
+
+wsLinkStateAlarmNotificationOtuBdi OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "OTU backwards defect indicator."
+ ::= { wsLinkStateAlarmNotificationOtuDefects 7 }
+
+wsLinkStateAlarmNotificationOtuTtiMismatch OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "OTU TTI mismatch."
+ ::= { wsLinkStateAlarmNotificationOtuDefects 8 }
+
+-- ODU
+wsLinkStateAlarmNotificationOduDefects OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "ODU layer defects."
+ ::= { wsLinkStateAlarmNotification 13 }
+
+wsLinkStateAlarmNotificationOduOci OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ODU open connection indication."
+ ::= { wsLinkStateAlarmNotificationOduDefects 1 }
+
+wsLinkStateAlarmNotificationOduAis OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ODU alarm indicating signal."
+ ::= { wsLinkStateAlarmNotificationOduDefects 2 }
+
+wsLinkStateAlarmNotificationOduLck OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ODU locked."
+ ::= { wsLinkStateAlarmNotificationOduDefects 3 }
+
+wsLinkStateAlarmNotificationOduSf OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ODU signal fail."
+ ::= { wsLinkStateAlarmNotificationOduDefects 4 }
+
+wsLinkStateAlarmNotificationOduSd OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ODU signal degrade."
+ ::= { wsLinkStateAlarmNotificationOduDefects 5 }
+
+wsLinkStateAlarmNotificationOduTtiMismatch OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ODU TTI mismatch."
+ ::= { wsLinkStateAlarmNotificationOduDefects 6 }
+
+wsLinkStateAlarmNotificationOduBdi OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ODU backwards defect indicator."
+ ::= { wsLinkStateAlarmNotificationOduDefects 7 }
+
+wsLinkStateAlarmNotificationOduPtiMismatch OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ODU payload type indicator mismatch."
+ ::= { wsLinkStateAlarmNotificationOduDefects 8 }
+
+wsLinkStateAlarmNotificationOduFeClientSf OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ODU far-end client signal fail."
+ ::= { wsLinkStateAlarmNotificationOduDefects 9 }
+
+wsLinkStateAlarmNotificationOduSkewOor OBJECT-TYPE
+ SYNTAX INTEGER {
+ inactive(0),
+ active(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ODU skew out of range."
+ ::= { wsLinkStateAlarmNotificationOduDefects 10 }
+
+wsLinkStateAlarmNotificationEntityType OBJECT-TYPE
+ SYNTAX INTEGER {
+ notApplicable(0),
+ other(1),
+ clientPort(2),
+ linePort(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm source entity type if applicable."
+ ::= { wsLinkStateAlarmNotification 14 }
+
+END