diff options
Diffstat (limited to 'MIBS/cisco/CISCO-POWER-ETHERNET-EXT-MIB')
| -rw-r--r-- | MIBS/cisco/CISCO-POWER-ETHERNET-EXT-MIB | 1735 |
1 files changed, 1735 insertions, 0 deletions
diff --git a/MIBS/cisco/CISCO-POWER-ETHERNET-EXT-MIB b/MIBS/cisco/CISCO-POWER-ETHERNET-EXT-MIB new file mode 100644 index 0000000..b7429f1 --- /dev/null +++ b/MIBS/cisco/CISCO-POWER-ETHERNET-EXT-MIB @@ -0,0 +1,1735 @@ +-- ***************************************************************** +-- CISCO-POWER-ETHERNET-EXT-MIB +-- +-- Ported from flo_dsbu7 +-- +-- Nov 2011, ovld-sw-platform-dev +-- March 2004, Seth Wang +-- +-- Copyright (c) 2004-2007, 2010-2013, 2017-2018 by Cisco Systems, Inc. +-- +-- All rights reserved. +-- **************************************************************** + +CISCO-POWER-ETHERNET-EXT-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, + OBJECT-TYPE, + Unsigned32, + NOTIFICATION-TYPE + FROM SNMPv2-SMI + MODULE-COMPLIANCE, + OBJECT-GROUP, + NOTIFICATION-GROUP + FROM SNMPv2-CONF + TEXTUAL-CONVENTION, + TruthValue + FROM SNMPv2-TC + pethPsePortEntry, + pethMainPseGroupIndex, + pethPsePortGroupIndex, + pethPsePortIndex + FROM POWER-ETHERNET-MIB + SnmpAdminString + FROM SNMP-FRAMEWORK-MIB + EntPhysicalIndexOrZero + FROM CISCO-TC + ciscoMgmt + FROM CISCO-SMI; + + +ciscoPowerEthernetExtMIB MODULE-IDENTITY + LAST-UPDATED "201801190000Z" + ORGANIZATION "Cisco Systems, Inc." + CONTACT-INFO + "Cisco Systems + Customer Service + + Postal: 170 W Tasman Drive + San Jose, CA 95134 + USA + + Tel: +1 800 553-NETS + + E-mail: cs-lan-switch-snmp@cisco.com" + DESCRIPTION + "A MIB module for extending the POWER-ETHERNET-MIB + (RFC3621) to add objects which provide additional + management information about Power Sourcing Equipment + (PSE) not available in POWER-ETHERNET-MIB. + + Glossary + + Power Sourcing Equipment (PSE) + These are devices supplying electrical power to + other equipment. They are, for example, inline power + switches, inline power daughterboards and power patch + panels. + + Powered Device (PD) + These are devices receiving their electrical power + supply from Power Sourcing Equipment. They are, for + example, IP telephones and wireless access points + or bridges." + REVISION "201801190000Z" + DESCRIPTION + "Added following OBJECT-GROUP + - cpeExtPseInfoPwrGroup + Added new compliance + - cpeExtMIBCompliance6." + REVISION "201307100000Z" + DESCRIPTION + "Added following TEXTUAL-CONVENTION + - CpeExtLldpPwrClassOrZero + Added following OBJECT-GROUP + - cpeExtPsePortLldpPowerGroup + Added new compliance + - cpeExtMIBCompliance5." + REVISION "201107180000Z" + DESCRIPTION + "Added cpeExtPowerPriorityGroup, cpeExtPsePortLldpGroup + and cpeExtPsePortCapabilitiesGroup. + + Added a new enumeration 'class4' in cpeExtPdStatsClass. + + Added TEXTUAL-CONVENTION CpeExtLldpPwrType, + CpeExtLldpPwrSrc, and CpeExtPwrPriority." + REVISION "200912040000Z" + DESCRIPTION + "Updated the DESCRIPTION of cpeExtPolicingNotif." + REVISION "200704120000Z" + DESCRIPTION + "Added 'overdrawLog' value to cpeExtPsePortAdditionalStatus. + Added cpeExtPortPolicingActionGroup, cpeExtPortPwrManAllocGroup + cpeExtPolicingNotifEnableGroup, and cpeExtPolicingNotifGroup." + REVISION "200702020000Z" + DESCRIPTION + "Added cpeExtPsePortEntPhyIndex, + cpeExtPsePortPolicingCapable and + cpeExtPsePortPolicingEnable to cpeExtPsePortTable. + Added cpeExtPdStatsTotalDevices and cpeExtPdStatsTable. + Added enumerated value disable(5) to cpeExtPsePortEnable." + REVISION "200506100000Z" + DESCRIPTION + "Added 'limit' to cpeExtPsePortEnable, 'overdraw' to + cpeExtPsePortAdditionalStatus and the groups + cpeExtPsePortPwrMonitorGroup and + cpeExtMainPseGroup." + REVISION "200404120000Z" + DESCRIPTION + "Initial version of this MIB module." + ::= { ciscoMgmt 402 } + + +cpeExtMIBNotifs OBJECT IDENTIFIER + ::= { ciscoPowerEthernetExtMIB 0 } + +cpeExtMIBObjects OBJECT IDENTIFIER + ::= { ciscoPowerEthernetExtMIB 1 } + +cpeExtMIBConformance OBJECT IDENTIFIER + ::= { ciscoPowerEthernetExtMIB 2 } + + +CpeExtLldpPwrType ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The requested Data Terminal Equipment (DTE) Power via + Media Dependent Interface (MDI) type based on Data Link Layer + (DLL) power classification. + + In Data Link Layer power classification, the PSE and PD perform + power negotiation using the Link Layer Discovery Protocol (LLDP) + as soon as the data link is established. It has finer power + resolution than the Physical Layer power classification and has + the ability for the PSE and PD to participate in dynamic power + allocation wherein allocated power to the PD may change one or + more times during PD operation. + + 'type1Pd' - A PD that advertises a power draw less than or + equal to 12.95 W (at the PD). + 'type1Pse' - A PSE that is designed to support a Type 1 PD. + 'type2Pd' - A PD that advertises a power draw greater than + 12.95 W (at the PD). + 'type2Pse - A PSE that is designed to support either a Type 1 + or a Type 2 PD." + SYNTAX INTEGER { + type1Pd(1), + type1Pse(2), + type2Pd(3), + type2Pse(4) + } + +CpeExtLldpPwrSrc ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The power source of the PD or PSE port which implements the + LLDP based Data Link Layer power classification. + + 'pseAndLocal' - A PD powered both locally and by a PSE. + 'local' - A PD powered locally only. + 'pse' - A PD powered by a PSE only. + 'backupSrc' - A PSE powered by a backup power source. + 'primarySrc' - A PSE powered by its primary power source. + 'unknown' - A PD or PSE where the power source is + unknown." + SYNTAX INTEGER { + pseAndLocal(1), + local(2), + pse(3), + backupSrc(4), + primarySrc(5), + unknown(6) + } + +CpeExtPwrPriority ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The power priority for the PD on the PSE port which implements + the LLDP based Data Link Layer power classification. + + 'critical' - power priority is at critical level. + 'high' - power priority is at high level. + 'low' - power priority is at low level. + 'unknown' - power priority level is unknown." + SYNTAX INTEGER { + critical(1), + high(2), + low(3), + unknown(4) + } + +CpeExtLldpPwrClassOrZero ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The power class of the PD or PSE port that implements + the LLDP based Data Link Layer power classification + + 'unknown' - power classification of the powered devices is + unknown. + + 'class0' - power classification of the powered devices is + class 0 in IEEE specifications. + + 'class1' - power classification of the powered devices is + class 1 in IEEE specifications. + + 'class2' - power classification of the powered devices is + class 2 in IEEE specifications. + + 'class3' - power classification of the powered devices is + class 3 in IEEE specifications. + + 'class4' - power classification of the powered devices is + class 4 in IEEE specifications." + SYNTAX INTEGER { + unknown(0), + class0(1), + class1(2), + class2(3), + class3(4), + class4(5) + } + +cpeExtDefaultAllocation OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliwatts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object indicates the default inline power allocation per + port. This is a global configuration parameter that applies + to all inline power capable ports in the system. + + The system must consider this object as well as the per port + configuration object, cpeExtPsePortPwrMax, when determining + how much power to allocate to a port. The system will use the + lower of the two numbers." + ::= { cpeExtMIBObjects 1 } + +cpeExtPsePortTable OBJECT-TYPE + SYNTAX SEQUENCE OF CpeExtPsePortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table extends the POWER-ETHERNET-MIB pethPsePortTable + for power Ethernet ports on a Powered Sourcing Equipment + (PSE) device." + REFERENCE "RFC3621" + ::= { cpeExtMIBObjects 2 } + +cpeExtPsePortEntry OBJECT-TYPE + SYNTAX CpeExtPsePortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A cpeExtPsePortEntry extends a corresponding + pethPsePortTable entry. This entry displays and + controls more characteristics of a power Ethernet + port on a PSE device." + AUGMENTS { pethPsePortEntry } + ::= { cpeExtPsePortTable 1 } + +CpeExtPsePortEntry ::= SEQUENCE { + cpeExtPsePortEnable INTEGER, + cpeExtPsePortDiscoverMode INTEGER, + cpeExtPsePortDeviceDetected TruthValue, + cpeExtPsePortIeeePd TruthValue, + cpeExtPsePortAdditionalStatus BITS, + cpeExtPsePortPwrMax Unsigned32, + cpeExtPsePortPwrAllocated Unsigned32, + cpeExtPsePortPwrAvailable Unsigned32, + cpeExtPsePortPwrConsumption Unsigned32, + cpeExtPsePortMaxPwrDrawn Unsigned32, + cpeExtPsePortEntPhyIndex EntPhysicalIndexOrZero, + cpeExtPsePortPolicingCapable TruthValue, + cpeExtPsePortPolicingEnable INTEGER, + cpeExtPsePortPolicingAction INTEGER, + cpeExtPsePortPwrManAlloc Unsigned32, + cpeExtPsePortCapabilities BITS +} + +cpeExtPsePortEnable OBJECT-TYPE + SYNTAX INTEGER { + auto(1), + static(2), + limit(3), + disable(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is an extension of the pethPsePortAdminEnable + object from RFC3621. It allows the user to be more specific + when enabling the PSE functions. The states, 'auto', 'static' + and 'limit' correspond to a value of 'true' for the + pethPsePortAdminEnable object. The state 'disable' corresponds + to a value of 'false' for the pethPsePortAdminEnable object. + + Setting this value to 'auto' enables Powered Device discovery + on the interface and the amount of power allocated depends on + the Powered Device discovered. If pethPsePortAdminEnable was + 'false' prior to this set operation, then it will become + 'true'. + + Setting this value to 'static' will also enable Powered + Device discovery. However, this is different from 'auto' + in that the amount of power is pre-allocated based on the + configuration on the Power Sourcing Equipment. If + pethPsePortAdminEnable was 'false' prior to this set + operation, then it will become 'true'. + + Setting this value to 'limit' enables Powered Device + discovery on the interface. The amount of power allocated + depends on the Powered Device discovered and the value + of cpeExtPsePortPwrMax. The lower value will be used. + If pethPsePortAdminEnable was 'false' prior to this set + operation, then it will become 'true'. + + Setting this value to 'disable' disables the PSE functions. + The pethPsePortAdminEnable object will adopt the value of + 'false' if it was 'true' prior to this set operation. When + setting the pethPsePortAdminEnable object to 'false' this + object cpeExtPsePortEnable will adopt the value of 'disable'. + + If cpeExtPsePortPolicingCapable of the PSE port, or + cpeExtMainPsePwrMonitorCapable of the PSE port's + main group, has the value of 'false', this object + can only be set to 'auto', 'static' or 'disable'. + Otherwise, this object can be set to 'auto', 'static', + 'limit' or 'disable'." + ::= { cpeExtPsePortEntry 1 } + +cpeExtPsePortDiscoverMode OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + off(2), + ieee(3), + cisco(4), + ieeeAndCisco(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the discover mode used by the system to + discover the PD. + + A value of 'unknown' indicates that the discover mode on the + interface is unknown. + + A value of 'off' indicates that discovery is disabled on the + interface. + + A value of 'ieee' indicates that the discover mode on the + interface is IEEE based. + + A value of 'cisco' indicates that the discover mode on the + interface is Cisco based. + + A value of 'ieeeAndCisco' indicates that the discover mode on + the interface is both IEEE and Cisco based." + ::= { cpeExtPsePortEntry 2 } + +cpeExtPsePortDeviceDetected OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates if a Powered Device (PD) has been + detected on the interface. + + A value of 'true' indicates that a PD has been detected on + the interface. + + A value of 'false' indicates that no PD has been detected on + the interface." + ::= { cpeExtPsePortEntry 3 } + +cpeExtPsePortIeeePd OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates whether the Powered Device attached + to the interface is an IEEE compliant Powered Device or not. + + A value of 'true' indicates the attached Powered Device is + an IEEE compliant Powered Device. + + A value of 'false' indicates the attached Powered Device + is not an IEEE compliant Powered Device. This also means + that the value of the corresponding object from the + pethPsePortTable, pethPsePortPowerClassifications is + irrelevant." + ::= { cpeExtPsePortEntry 4 } + +cpeExtPsePortAdditionalStatus OBJECT-TYPE + SYNTAX BITS { + deny(0), + overdraw(1), + overdrawLog(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is an extension of the pethPsePortDetectionStatus + object from RFC3621 and provides additional status + information. + + deny: When set, the PD attached to the interface is being + denied power due to insufficient power resources on + the Power Sourcing Equipment. + + overdraw: When set, the PD attached to the interface is + being denied power because the PD is trying + to consume more power than it has been + configured to consume. + + overdrawLog: When set, the PD attached to the interface + is trying to consume more power than it has + been configured to consume, but is not being + denied power." + ::= { cpeExtPsePortEntry 5 } + +cpeExtPsePortPwrMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliwatts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This indicates the maximum amount of power that the PSE will + make available to the PD connected to this interface." + ::= { cpeExtPsePortEntry 6 } + +cpeExtPsePortPwrAllocated OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliwatts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the amount of power allocated from the + PSE for the PD." + ::= { cpeExtPsePortEntry 7 } + +cpeExtPsePortPwrAvailable OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliwatts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the amount of power available for + the PD to use. This value may differ from the value + cpeExtPsePortPwrAllocated due to the efficiency issues + of delivering the power from the PSE to the PD. + + When sufficient power is available to power a PD, this + value should be equal to the lower of the two objects, + cpeExtDefaultAllocation and cpeExtPsePortPwrMax." + ::= { cpeExtPsePortEntry 8 } + +cpeExtPsePortPwrConsumption OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliwatts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This indicates the actual power consumption of the PD + connected to this interface. It may not necessarily + be equal to the value of cpeExtPsePortPwrAvailable." + ::= { cpeExtPsePortEntry 9 } + +cpeExtPsePortMaxPwrDrawn OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliwatts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This indicates the maximum amount of power drawn by the PD + connected to this interface, since it was powered on." + ::= { cpeExtPsePortEntry 10 } + +cpeExtPsePortEntPhyIndex OBJECT-TYPE + SYNTAX EntPhysicalIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The entPhysicalIndex value that uniquely identifies the + PSE port. If the PSE port does not have a corresponding + physical entry in entPhysicalTable or if the + entPhysicalTable is not supported by the management + system, this object has the value of zero." + REFERENCE "RFC 2737, entPhysicalIndex." + ::= { cpeExtPsePortEntry 11 } + +cpeExtPsePortPolicingCapable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates whether the PSE port hardware is + capable of policing the port for proper power consumption + based on the allocated value." + ::= { cpeExtPsePortEntry 12 } + +cpeExtPsePortPolicingEnable OBJECT-TYPE + SYNTAX INTEGER { + on(1), + off(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object allows the user to turn on or turn off the + power policing of the PSE port. If the instance value of + cpeExtPsePortPolicingCapable is 'TRUE', the user is allowed + to set this object to 'on' or 'off'. Otherwise, this + object is read-only and always has the value of 'off'." + ::= { cpeExtPsePortEntry 13 } + +cpeExtPsePortPolicingAction OBJECT-TYPE + SYNTAX INTEGER { + deny(1), + logOnly(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies the power policing action that + the device will take on this PSE port when the real-time + power consumption exceeds its max power allocation if + the value of cpeExtPsePortPolicingEnable is 'on'. + 'deny' - the device will deny the power to + the PSE port + 'logOnly' - the device will not deny the power + to the PSE port" + ::= { cpeExtPsePortEntry 14 } + +cpeExtPsePortPwrManAlloc OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliwatts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies the manual power allocation that + the PSE will allocate to the PD connected to this + interface regardless of the amount requested via CDP + or IEEE. + + Setting this object value to zero disables the manual + power allocation. + + Warning: Misconfiguring this manual power allocation may + cause damage to the system and void the warranty. Take + precautions not to oversubscribe the power supply." + ::= { cpeExtPsePortEntry 15 } + +cpeExtPsePortCapabilities OBJECT-TYPE + SYNTAX BITS { + policing(0), + poePlus(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the PSE functionality that + this port supports. + + If the 'policing' BIT is set, then this PSE port is + capable of policing the port for proper power consumption + based on the allocated value. + + If the 'poePlus' BIT is set, then this PSE port supports + PoE Plus functions." + ::= { cpeExtPsePortEntry 16 } + + + +cpeExtMainPseTable OBJECT-TYPE + SYNTAX SEQUENCE OF CpeExtMainPseEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the additional information for the + main PSE group in pethMainPseTable." + REFERENCE "RFC3621, pethMainPseTable" + ::= { cpeExtMIBObjects 3 } + +cpeExtMainPseEntry OBJECT-TYPE + SYNTAX CpeExtMainPseEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A cpeExtMainPseEntry contains information about + a particular pethMainPseGroupIndex. An entry is + created by the agent when a main PSE group is added + to the pethMainPseTable. An entry is deleted by the + agent when a main PSE group is removed from the + pethMainPseTable." + REFERENCE "RFC3621, pethMainPseTable" + INDEX { pethMainPseGroupIndex } + ::= { cpeExtMainPseTable 1 } + +CpeExtMainPseEntry ::= SEQUENCE { + cpeExtMainPseEntPhyIndex EntPhysicalIndexOrZero, + cpeExtMainPseDescr SnmpAdminString, + cpeExtMainPsePwrMonitorCapable TruthValue, + cpeExtMainPseUsedPower Unsigned32, + cpeExtMainPseRemainingPower Unsigned32 +} + +cpeExtMainPseEntPhyIndex OBJECT-TYPE + SYNTAX EntPhysicalIndexOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The entPhysicalIndex value that uniquely identifies the + main PSE group. If the main PSE group does not have a + corresponding physical entry in entPhysicalTable or if + the entPhysicalTable is not supported by the management + system, then this object has the value of zero." + REFERENCE "RFC 2737, entPhysicalIndex." + ::= { cpeExtMainPseEntry 1 } + +cpeExtMainPseDescr OBJECT-TYPE + SYNTAX SnmpAdminString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A textual string containing information about the Power + Source Equipment (PSE) group." + ::= { cpeExtMainPseEntry 2 } + +cpeExtMainPsePwrMonitorCapable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates if the given group is capable of + monitoring the power consumption of the interfaces that + belong to the group. The value 'true' means that the + group is capable. The value 'false' means that the group + in not capable." + ::= { cpeExtMainPseEntry 3 } + +cpeExtMainPseUsedPower OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "miliwatts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates used power expressed in miliwatts." + ::= { cpeExtMainPseEntry 4 } + +cpeExtMainPseRemainingPower OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "miliwatts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates remaining power expressed in + miliwatts, this parameter is calculated as pethMainPsePower + minus cpeExtMainPseUsedPower." + ::= { cpeExtMainPseEntry 5 } + + +cpeExtPdStatistics OBJECT IDENTIFIER + ::= { cpeExtMIBObjects 4 } + + +cpeExtPdStatsTotalDevices OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the total number of the + powered devices with any power classifications + in the system. + + Classification is a way to tag different terminals + on the Power over LAN network according to their + power consumption. Devices such as IP telephones, + WLAN access points and others, will be classified + according to their power requirements." + REFERENCE + "IEEE Std 802.3af Section 30.9.1.1.6 + aPSEPowerClassification" + ::= { cpeExtPdStatistics 1 } + +cpeExtPdStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF CpeExtPdStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the statistics information + of the powered devices fallen into different power + classifications in the system." + REFERENCE + "IEEE Std 802.3af Section 30.9.1.1.6 + aPSEPowerClassification" + ::= { cpeExtPdStatistics 2 } + +cpeExtPdStatsEntry OBJECT-TYPE + SYNTAX CpeExtPdStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A cpeExtPdStatsEntry contains the statistics + information about a particular power classification + defined in cpeExtPdStatsIndex." + INDEX { cpeExtPdStatsClass } + ::= { cpeExtPdStatsTable 1 } + +CpeExtPdStatsEntry ::= SEQUENCE { + cpeExtPdStatsClass INTEGER, + cpeExtPdStatsDeviceCount Unsigned32 +} + +cpeExtPdStatsClass OBJECT-TYPE + SYNTAX INTEGER { + cisco(1), + class0(2), + class1(3), + class2(4), + class3(5), + class4(6) + } + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The power classification as the index for the + statistics information for powered devices. + + A value of 'cisco' indicates that the powered + devices are CISCO proprietary and their power + classification does not fall into any class + in IEEE specifications. + + A value of 'class0' indicates that the power + classification of the powered devices falls into + class 0 in IEEE specifications. + + A value of 'class1' indicates that the power + classification of the powered devices falls into + class 1 in IEEE specifications. + + A value of 'class2' indicates that the power + classification of the powered devices falls into + class 2 in IEEE specifications. + + A value of 'class3' indicates that the power + classification of the powered devices falls into + class 3 in IEEE specifications. + + A value of 'class4' indicates that the power + classification of the powered devices falls into + class 4 in IEEE specifications." + REFERENCE + "IEEE Std 802.3af Section 30.9.1.1.6 + aPSEPowerClassification" + ::= { cpeExtPdStatsEntry 1 } + +cpeExtPdStatsDeviceCount OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the count of the powered + devices whose power classification falls into + a specific value of cpeExtPdStatsIndex." + ::= { cpeExtPdStatsEntry 2 } + + + +cpeExtPolicingNotifEnable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is used to enable/disable the + the cpeExtPolicingNotif notification." + ::= { cpeExtMIBObjects 5 } + +cpeExtPowerPriorityEnable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object is the global control of the power priority + feature on the device. 'true' indicates that the power priority + feature is globally enabled. 'false' indicates that the power + priority feature is globally disabled." + ::= { cpeExtMIBObjects 6 } + +cpeExtPsePortLldpTable OBJECT-TYPE + SYNTAX SEQUENCE OF CpeExtPsePortLldpEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table provides the Link Layer Discovery Protocol (LLDP) + based Data Link Layer (DLL) power classification + characteristics of PSE ports and PDs attached to them." + ::= { cpeExtMIBObjects 7 } + +cpeExtPsePortLldpEntry OBJECT-TYPE + SYNTAX CpeExtPsePortLldpEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A cpeExtPsePortLldpEntry entry contains the LLDP + based 802.3at DLL power classification characteristics for + a particular PSE and the PD attached to it. + + A PSE has its entry here when all of the following conditions + are satisfied: + - The LLDP power classification is globally enabled. + - It has a PD attached. + - LLDP is the operational power negotiation protocol between + the PSE and the PD attached." + INDEX { + pethPsePortGroupIndex, + pethPsePortIndex + } + ::= { cpeExtPsePortLldpTable 1 } + +CpeExtPsePortLldpEntry ::= SEQUENCE { + cpeExtPsePortLldpPwrType CpeExtLldpPwrType, + cpeExtPsePortLldpPdPwrType CpeExtLldpPwrType, + cpeExtPsePortLldpPwrSrc CpeExtLldpPwrSrc, + cpeExtPsePortLldpPdPwrSrc CpeExtLldpPwrSrc, + cpeExtPsePortLldpPwrPriority CpeExtPwrPriority, + cpeExtPsePortLldpPdPwrPriority CpeExtPwrPriority, + cpeExtPsePortLldpPwrReq Unsigned32, + cpeExtPsePortLldpPdPwrReq Unsigned32, + cpeExtPsePortLldpPwrAlloc Unsigned32, + cpeExtPsePortLldpPdPwrAlloc Unsigned32, + cpeExtPsePortLldpPwrClass CpeExtLldpPwrClassOrZero, + cpeExtPsePortLldpPdPwrClass CpeExtLldpPwrClassOrZero, + cpeExtPsePortLldpPdPwrSupport BITS, + cpeExtPsePortLldpPdPwrPairsOrZero INTEGER +} + +cpeExtPsePortLldpPwrType OBJECT-TYPE + SYNTAX CpeExtLldpPwrType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The DTE Power via MDI type of the local system (PSE)." + ::= { cpeExtPsePortLldpEntry 1 } + +cpeExtPsePortLldpPdPwrType OBJECT-TYPE + SYNTAX CpeExtLldpPwrType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The DTE Power via MDI type of the remote system (PD)." + ::= { cpeExtPsePortLldpEntry 2 } + +cpeExtPsePortLldpPwrSrc OBJECT-TYPE + SYNTAX CpeExtLldpPwrSrc + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power source of the local system (PSE)." + ::= { cpeExtPsePortLldpEntry 3 } + +cpeExtPsePortLldpPdPwrSrc OBJECT-TYPE + SYNTAX CpeExtLldpPwrSrc + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power source of the remote system (PD)." + ::= { cpeExtPsePortLldpEntry 4 } + +cpeExtPsePortLldpPwrPriority OBJECT-TYPE + SYNTAX CpeExtPwrPriority + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power priority of the local system (PSE)." + ::= { cpeExtPsePortLldpEntry 5 } + +cpeExtPsePortLldpPdPwrPriority OBJECT-TYPE + SYNTAX CpeExtPwrPriority + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power priority of the remote system (PD)." + ::= { cpeExtPsePortLldpEntry 6 } + +cpeExtPsePortLldpPwrReq OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliwatts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The requested PD power value that the local + system (PSE) mirrors back to the remote system (PD)." + ::= { cpeExtPsePortLldpEntry 7 } + +cpeExtPsePortLldpPdPwrReq OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliwatts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The PD requested power value received from + the remote system (PD)." + ::= { cpeExtPsePortLldpEntry 8 } + +cpeExtPsePortLldpPwrAlloc OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliwatts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The PSE allocated power value for the remote + system (PD)." + ::= { cpeExtPsePortLldpEntry 9 } + +cpeExtPsePortLldpPdPwrAlloc OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "milliwatts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The PSE allocated power value received from the + remote system (PD)." + ::= { cpeExtPsePortLldpEntry 10 } + +cpeExtPsePortLldpPwrClass OBJECT-TYPE + SYNTAX CpeExtLldpPwrClassOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The PSE power classification sent to the remote PD via MDI TLV + in LLDP Protocol." + REFERENCE + "IEEE Std 802.3af Section 30.9.1.1.6 + aPSEPowerClassification" + ::= { cpeExtPsePortLldpEntry 11 } + +cpeExtPsePortLldpPdPwrClass OBJECT-TYPE + SYNTAX CpeExtLldpPwrClassOrZero + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This power classification received from the remote + system (PD)." + REFERENCE + "IEEE Std 802.3af Section 30.9.1.1.6 + aPSEPowerClassification" + ::= { cpeExtPsePortLldpEntry 12 } + +cpeExtPsePortLldpPdPwrSupport OBJECT-TYPE + SYNTAX BITS { + portClass(0), + pseMdiPwrSupport(1), + pseMdiPwrState(2), + psePairCtrlAbility(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the power support mode received + from the remote PD via MDI TLV in LLDP protocol. + + 'portClass' - This bit is set if the port is + operating as PSE. Otherwise, it is + operating as PD. + + 'pseMdiPwrSupport' - This bit is set if power is supported in + MDI TLV. + + 'pseMdiPwrState' - This bit is set if power is enabled. + + 'psePairCtrlAbility' - This bit is set if pair selection can + be controlled." + ::= { cpeExtPsePortLldpEntry 13 } + +cpeExtPsePortLldpPdPwrPairsOrZero OBJECT-TYPE + SYNTAX INTEGER { + unknown(0), + signal(1), + spare(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the pinout pairs in use received + from the remote PD via MDI TLV in LLDP Protocol. + + 'unknown' - information is not available + + 'signal' - the signal pairs are in use. + + 'spare' - the spare pairs are in use." + ::= { cpeExtPsePortLldpEntry 14 } + + + +-- Notifications + +cpeExtPolicingNotif NOTIFICATION-TYPE + OBJECTS { + cpeExtPsePortPolicingAction, + cpeExtPsePortAdditionalStatus, + cpeExtPsePortPwrAllocated, + cpeExtPsePortMaxPwrDrawn + } + STATUS current + DESCRIPTION + "This notification is generated when the 'overdraw' or + 'overdrawLog' bit in value of cpeExtPsePortAdditionalStatus + is set or cleared." + ::= { cpeExtMIBNotifs 1 } +-- Conformance + +cpeExtMIBCompliances OBJECT IDENTIFIER + ::= { cpeExtMIBConformance 1 } + +cpeExtMIBGroups OBJECT IDENTIFIER + ::= { cpeExtMIBConformance 2 } + + +cpeExtMIBCompliance MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for the + CISCO-POWER-ETHERNET-EXT-MIB." + MODULE -- this module + MANDATORY-GROUPS { cpeExtPsePortGroup } + + GROUP cpeExtPsePortGlobalConfigGroup + DESCRIPTION + "The cpeExtPsePortGlobalConfigGroup is mandatory for agents + that support global configurations on the PSE interfaces." + ::= { cpeExtMIBCompliances 1 } + +cpeExtMIBCompliance2 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for the + CISCO-POWER-ETHERNET-EXT-MIB." + MODULE -- this module + MANDATORY-GROUPS { cpeExtPsePortGroup } + + GROUP cpeExtPsePortGlobalConfigGroup + DESCRIPTION + "The cpeExtPsePortGlobalConfigGroup is mandatory for agents + that support global configurations on the PSE interfaces." + + GROUP cpeExtPsePortPwrMonitorGroup + DESCRIPTION + "The cpeExtPsePortPwrMonitorGroup is mandatory for agents + that provide power monitoring on PD's connected to the + PSE interfaces." + + GROUP cpeExtMainPseGroup + DESCRIPTION + "The cpeExtMainPseGroup is mandatory for agents + that support the interface power consumption + monitoring, or need additional info to identify + the PSE group." + ::= { cpeExtMIBCompliances 2 } + +cpeExtMIBCompliance3 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for the + CISCO-POWER-ETHERNET-EXT-MIB." + MODULE -- this module + MANDATORY-GROUPS { cpeExtPsePortGroup } + + GROUP cpeExtPsePortGlobalConfigGroup + DESCRIPTION + "The cpeExtPsePortGlobalConfigGroup is mandatory for agents + that support global configurations on the PSE interfaces." + + GROUP cpeExtPsePortPwrMonitorGroup + DESCRIPTION + "The cpeExtPsePortPwrMonitorGroup is mandatory for agents + that provide power monitoring on PD's connected to the + PSE interfaces." + + GROUP cpeExtMainPseGroup2 + DESCRIPTION + "The cpeExtMainPseGroup2 is mandatory for agents + that need additional information to identify the PSE + group." + + GROUP cpeExtPseGrpPwrGroup + DESCRIPTION + "The cpeExtPseGrpPwrGroup is mandatory for agents + that support the power consumption monitoring for + PSE groups." + + GROUP cpeExtPortEntityIndexGroup + DESCRIPTION + "The cpeExtPortEntityIndexGroup is mandatory for agents + that needs additional info to identify the interfaces + of the PSE port." + + GROUP cpeExtPortPolicingGroup + DESCRIPTION + "The cpeExtPortPolicingGroup is mandatory for agents + that provide power consumption policing for the PSE + ports." + + GROUP cpeExtPdStatsGroup + DESCRIPTION + "The cpeExtPdStatsGroup is mandatory for agents + that provide the statistics information for powered + devices." + + GROUP cpeExtPortPolicingActionGroup + DESCRIPTION + "The cpeExtPortPolicingActionGroup is mandatory + for agents that provide control of the power policing + action." + + GROUP cpeExtPortPwrManAllocGroup + DESCRIPTION + "The cpeExtPortPolicingActionGroup is mandatory + for agents that provide manual power allocation." + + GROUP cpeExtPolicingNotifEnableGroup + DESCRIPTION + "The cpeExtPolicingNotifEnableGroup is mandatory for agents + that provide notifications of power consumption policing + status for the PSE ports." + + GROUP cpeExtPolicingNotifGroup + DESCRIPTION + "The cpeExtPolicingNotifGroup is mandatory for agents + that provide notifications of power consumption policing + status for the PSE ports." + ::= { cpeExtMIBCompliances 3 } + +cpeExtMIBCompliance4 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for the + CISCO-POWER-ETHERNET-EXT-MIB." + MODULE -- this module + MANDATORY-GROUPS { cpeExtPsePortGroup } + + GROUP cpeExtPsePortGlobalConfigGroup + DESCRIPTION + "The cpeExtPsePortGlobalConfigGroup is mandatory for agents + that support global configurations on the PSE interfaces." + + GROUP cpeExtPsePortPwrMonitorGroup + DESCRIPTION + "The cpeExtPsePortPwrMonitorGroup is mandatory for agents + that provide power monitoring on PD's connected to the + PSE interfaces." + + GROUP cpeExtMainPseGroup2 + DESCRIPTION + "The cpeExtMainPseGroup2 is mandatory for agents + that need additional information to identify the PSE + group." + + GROUP cpeExtPseGrpPwrGroup + DESCRIPTION + "The cpeExtPseGrpPwrGroup is mandatory for agents + that support the power consumption monitoring for + PSE groups." + + GROUP cpeExtPortEntityIndexGroup + DESCRIPTION + "The cpeExtPortEntityIndexGroup is mandatory for agents + that needs additional info to identify the interfaces + of the PSE port." + + GROUP cpeExtPortPolicingGroup + DESCRIPTION + "The cpeExtPortPolicingGroup is mandatory for agents + that provide power consumption policing for the PSE + ports." + + GROUP cpeExtPdStatsGroup + DESCRIPTION + "The cpeExtPdStatsGroup is mandatory for agents + that provide the statistics information for powered + devices." + + GROUP cpeExtPortPolicingActionGroup + DESCRIPTION + "The cpeExtPortPolicingActionGroup is mandatory + for agents that provide control of the power policing + action." + + GROUP cpeExtPortPwrManAllocGroup + DESCRIPTION + "The cpeExtPortPolicingActionGroup is mandatory + for agents that provide manual power allocation." + + GROUP cpeExtPolicingNotifEnableGroup + DESCRIPTION + "The cpeExtPolicingNotifEnableGroup is mandatory for agents + that provide notifications of power consumption policing + status for the PSE ports." + + GROUP cpeExtPolicingNotifGroup + DESCRIPTION + "The cpeExtPolicingNotifGroup is mandatory for agents + that provide notifications of power consumption policing + status for the PSE ports." + + GROUP cpeExtPowerPriorityGroup + DESCRIPTION + "The cpeExtPowerPriorityGroup is mandatory for agents + that support global control of the power priority + feature." + + GROUP cpeExtPsePortLldpGroup + DESCRIPTION + "The cpeExtPsePortLldpGroup is mandatory for agents + that support the LLDP based Data Link Layer + power classification." + + GROUP cpeExtPsePortCapabilitiesGroup + DESCRIPTION + "The cpeExtPsePortCapabilitiesGroup is mandatory for agents + that support PSE port capabilities." + + OBJECT cpeExtPsePortEnable + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPsePortPwrMax + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPsePortPolicingEnable + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPsePortPolicingAction + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPsePortPwrManAlloc + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPolicingNotifEnable + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPowerPriorityEnable + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { cpeExtMIBCompliances 4 } + +cpeExtMIBCompliance5 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for the + CISCO-POWER-ETHERNET-EXT-MIB." + MODULE -- this module + MANDATORY-GROUPS { cpeExtPsePortGroup } + + GROUP cpeExtPsePortGlobalConfigGroup + DESCRIPTION + "The cpeExtPsePortGlobalConfigGroup is mandatory for agents + that support global configurations on the PSE interfaces." + + GROUP cpeExtPsePortPwrMonitorGroup + DESCRIPTION + "The cpeExtPsePortPwrMonitorGroup is mandatory for agents + that provide power monitoring on PD's connected to the + PSE interfaces." + + GROUP cpeExtMainPseGroup2 + DESCRIPTION + "The cpeExtMainPseGroup2 is mandatory for agents + that need additional information to identify the PSE + group." + + GROUP cpeExtPseGrpPwrGroup + DESCRIPTION + "The cpeExtPseGrpPwrGroup is mandatory for agents + that support the power consumption monitoring for + PSE groups." + + GROUP cpeExtPortEntityIndexGroup + DESCRIPTION + "The cpeExtPortEntityIndexGroup is mandatory for agents + that needs additional info to identify the interfaces + of the PSE port." + + GROUP cpeExtPortPolicingGroup + DESCRIPTION + "The cpeExtPortPolicingGroup is mandatory for agents + that provide power consumption policing for the PSE + ports." + + GROUP cpeExtPdStatsGroup + DESCRIPTION + "The cpeExtPdStatsGroup is mandatory for agents + that provide the statistics information for powered + devices." + + GROUP cpeExtPortPolicingActionGroup + DESCRIPTION + "The cpeExtPortPolicingActionGroup is mandatory + for agents that provide control of the power policing + action." + + GROUP cpeExtPortPwrManAllocGroup + DESCRIPTION + "The cpeExtPortPolicingActionGroup is mandatory + for agents that provide manual power allocation." + + GROUP cpeExtPolicingNotifEnableGroup + DESCRIPTION + "The cpeExtPolicingNotifEnableGroup is mandatory for agents + that provide notifications of power consumption policing + status for the PSE ports." + + GROUP cpeExtPolicingNotifGroup + DESCRIPTION + "The cpeExtPolicingNotifGroup is mandatory for agents + that provide notifications of power consumption policing + status for the PSE ports." + + GROUP cpeExtPowerPriorityGroup + DESCRIPTION + "The cpeExtPowerPriorityGroup is mandatory for agents + that support global control of the power priority + feature." + + GROUP cpeExtPsePortLldpGroup + DESCRIPTION + "The cpeExtPsePortLldpGroup is mandatory for agents + that support the LLDP based Data Link Layer + power classification." + + GROUP cpeExtPsePortCapabilitiesGroup + DESCRIPTION + "The cpeExtPsePortCapabilitiesGroup is mandatory for agents + that support PSE port capabilities." + + GROUP cpeExtPsePortLldpPowerGroup + DESCRIPTION + "The cpeExtPsePortLldpPowerGroup is mandatory for agents + that support Power via MDI TLV in LLDP protocol." + + OBJECT cpeExtPsePortEnable + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPsePortPwrMax + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPsePortPolicingEnable + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPsePortPolicingAction + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPsePortPwrManAlloc + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPolicingNotifEnable + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPowerPriorityEnable + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { cpeExtMIBCompliances 5 } + +cpeExtMIBCompliance6 MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for the + CISCO-POWER-ETHERNET-EXT-MIB." + MODULE -- this module + MANDATORY-GROUPS { cpeExtPsePortGroup } + + GROUP cpeExtPsePortGlobalConfigGroup + DESCRIPTION + "The cpeExtPsePortGlobalConfigGroup is mandatory for agents + that support global configurations on the PSE interfaces." + + GROUP cpeExtPsePortPwrMonitorGroup + DESCRIPTION + "The cpeExtPsePortPwrMonitorGroup is mandatory for agents + that provide power monitoring on PD's connected to the + PSE interfaces." + + GROUP cpeExtMainPseGroup2 + DESCRIPTION + "The cpeExtMainPseGroup2 is mandatory for agents + that need additional information to identify the PSE + group." + + GROUP cpeExtPseGrpPwrGroup + DESCRIPTION + "The cpeExtPseGrpPwrGroup is mandatory for agents + that support the power consumption monitoring for + PSE groups." + + GROUP cpeExtPortEntityIndexGroup + DESCRIPTION + "The cpeExtPortEntityIndexGroup is mandatory for agents + that needs additional info to identify the interfaces + of the PSE port." + + GROUP cpeExtPortPolicingGroup + DESCRIPTION + "The cpeExtPortPolicingGroup is mandatory for agents + that provide power consumption policing for the PSE + ports." + + GROUP cpeExtPdStatsGroup + DESCRIPTION + "The cpeExtPdStatsGroup is mandatory for agents + that provide the statistics information for powered + devices." + + GROUP cpeExtPortPolicingActionGroup + DESCRIPTION + "The cpeExtPortPolicingActionGroup is mandatory + for agents that provide control of the power policing + action." + + GROUP cpeExtPortPwrManAllocGroup + DESCRIPTION + "The cpeExtPortPolicingActionGroup is mandatory + for agents that provide manual power allocation." + + GROUP cpeExtPolicingNotifEnableGroup + DESCRIPTION + "The cpeExtPolicingNotifEnableGroup is mandatory for agents + that provide notifications of power consumption policing + status for the PSE ports." + + GROUP cpeExtPolicingNotifGroup + DESCRIPTION + "The cpeExtPolicingNotifGroup is mandatory for agents + that provide notifications of power consumption policing + status for the PSE ports." + + GROUP cpeExtPowerPriorityGroup + DESCRIPTION + "The cpeExtPowerPriorityGroup is mandatory for agents + that support global control of the power priority + feature." + + GROUP cpeExtPsePortLldpGroup + DESCRIPTION + "The cpeExtPsePortLldpGroup is mandatory for agents + that support the LLDP based Data Link Layer + power classification." + + GROUP cpeExtPsePortCapabilitiesGroup + DESCRIPTION + "The cpeExtPsePortCapabilitiesGroup is mandatory for agents + that support PSE port capabilities." + + GROUP cpeExtPsePortLldpPowerGroup + DESCRIPTION + "The cpeExtPsePortLldpPowerGroup is mandatory for agents + that support Power via MDI TLV in LLDP protocol." + + GROUP cpeExtPseInfoPwrGroup + DESCRIPTION + "The cpeExtPseInfoPwrGroup is mandatory for agents + that support used and remaining power info for PSE groups." + + OBJECT cpeExtPsePortEnable + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPsePortPwrMax + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPsePortPolicingEnable + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPsePortPolicingAction + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPsePortPwrManAlloc + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPolicingNotifEnable + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT cpeExtPowerPriorityEnable + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + ::= { cpeExtMIBCompliances 6 } + +-- Units of Conformance + +cpeExtPsePortGroup OBJECT-GROUP + OBJECTS { + cpeExtPsePortEnable, + cpeExtPsePortDiscoverMode, + cpeExtPsePortDeviceDetected, + cpeExtPsePortIeeePd, + cpeExtPsePortAdditionalStatus, + cpeExtPsePortPwrMax, + cpeExtPsePortPwrAllocated, + cpeExtPsePortPwrAvailable, + cpeExtPsePortPwrConsumption + } + STATUS current + DESCRIPTION + "This group provides information and configuration objects + in addition to those provided in the POWER-ETHERNET-MIB + (RFC3621)." + ::= { cpeExtMIBGroups 1 } + +cpeExtPsePortGlobalConfigGroup OBJECT-GROUP + OBJECTS { cpeExtDefaultAllocation } + STATUS current + DESCRIPTION + "This is a collection of objects which provide global + configuration of the PSE interfaces." + ::= { cpeExtMIBGroups 2 } + +cpeExtPsePortPwrMonitorGroup OBJECT-GROUP + OBJECTS { cpeExtPsePortMaxPwrDrawn } + STATUS current + DESCRIPTION + "This is a collection of objects which provide power + monitoring on PD's connected to the PSE interfaces." + ::= { cpeExtMIBGroups 3 } + +cpeExtMainPseGroup OBJECT-GROUP + OBJECTS { + cpeExtMainPseEntPhyIndex, + cpeExtMainPseDescr, + cpeExtMainPsePwrMonitorCapable + } + STATUS deprecated + DESCRIPTION + "This is a collection of objects which provide + additional information for the PSE group. + cpeExtMainPseGroup object is superseded by cpeExtMainPseGroup2, + and cpeExtPseGrpPwrGroup." + ::= { cpeExtMIBGroups 4 } + +cpeExtPortEntityIndexGroup OBJECT-GROUP + OBJECTS { cpeExtPsePortEntPhyIndex } + STATUS current + DESCRIPTION + "This is a collection of objects which provide + entity physical index information for PSE port." + ::= { cpeExtMIBGroups 5 } + +cpeExtPortPolicingGroup OBJECT-GROUP + OBJECTS { + cpeExtPsePortPolicingCapable, + cpeExtPsePortPolicingEnable + } + STATUS current + DESCRIPTION + "This is a collection of objects which provide + the hardware power consumption policing information + for PSE port." + ::= { cpeExtMIBGroups 6 } + +cpeExtPdStatsGroup OBJECT-GROUP + OBJECTS { + cpeExtPdStatsTotalDevices, + cpeExtPdStatsDeviceCount + } + STATUS current + DESCRIPTION + "This is a collection of objects which provide + the statistics information for powered devices." + ::= { cpeExtMIBGroups 7 } + +cpeExtMainPseGroup2 OBJECT-GROUP + OBJECTS { + cpeExtMainPseEntPhyIndex, + cpeExtMainPseDescr + } + STATUS current + DESCRIPTION + "This is a collection of objects which provide + additional information to identify the PSE group." + ::= { cpeExtMIBGroups 8 } + +cpeExtPseGrpPwrGroup OBJECT-GROUP + OBJECTS { cpeExtMainPsePwrMonitorCapable } + STATUS current + DESCRIPTION + "This is a collection of objects which provide + power monitoring information for the PSE group." + ::= { cpeExtMIBGroups 9 } + +cpeExtPortPolicingActionGroup OBJECT-GROUP + OBJECTS { cpeExtPsePortPolicingAction } + STATUS current + DESCRIPTION + "This is a collection of objects which provide control + of the power policing action of the PSE port." + ::= { cpeExtMIBGroups 10 } + +cpeExtPortPwrManAllocGroup OBJECT-GROUP + OBJECTS { cpeExtPsePortPwrManAlloc } + STATUS current + DESCRIPTION + "This is a collection of objects which provide manual + power allocation for the PSE port." + ::= { cpeExtMIBGroups 11 } + +cpeExtPolicingNotifEnableGroup OBJECT-GROUP + OBJECTS { cpeExtPolicingNotifEnable } + STATUS current + DESCRIPTION + "A collection of object that provides control over + power consumption policing status notification." + ::= { cpeExtMIBGroups 12 } + +cpeExtPolicingNotifGroup NOTIFICATION-GROUP + NOTIFICATIONS { cpeExtPolicingNotif } + STATUS current + DESCRIPTION + "This is a collection of notifications related to + power consumption policing information for PSE ports." + ::= { cpeExtMIBGroups 13 } + +cpeExtPowerPriorityGroup OBJECT-GROUP + OBJECTS { cpeExtPowerPriorityEnable } + STATUS current + DESCRIPTION + "A collection of objects which provides global + control of power priority feature." + ::= { cpeExtMIBGroups 14 } + +cpeExtPsePortLldpGroup OBJECT-GROUP + OBJECTS { + cpeExtPsePortLldpPwrType, + cpeExtPsePortLldpPdPwrType, + cpeExtPsePortLldpPwrSrc, + cpeExtPsePortLldpPdPwrSrc, + cpeExtPsePortLldpPwrPriority, + cpeExtPsePortLldpPdPwrPriority, + cpeExtPsePortLldpPwrReq, + cpeExtPsePortLldpPdPwrReq, + cpeExtPsePortLldpPwrAlloc, + cpeExtPsePortLldpPdPwrAlloc + } + STATUS current + DESCRIPTION + "A collection of objects which provides the + information about the LLDP based Data Link Layer + power classification characteristics of power Ethernet + PSE ports." + ::= { cpeExtMIBGroups 15 } + +cpeExtPsePortCapabilitiesGroup OBJECT-GROUP + OBJECTS { cpeExtPsePortCapabilities } + STATUS current + DESCRIPTION + "A collection of objects which provides PSE + port capabilities." + ::= { cpeExtMIBGroups 16 } + +cpeExtPsePortLldpPowerGroup OBJECT-GROUP + OBJECTS { + cpeExtPsePortLldpPwrClass, + cpeExtPsePortLldpPdPwrClass, + cpeExtPsePortLldpPdPwrSupport, + cpeExtPsePortLldpPdPwrPairsOrZero + } + STATUS current + DESCRIPTION + "A collection of objects which provide Power information + via MDI TLV in LLDP Protocol." + ::= { cpeExtMIBGroups 17 } + +cpeExtPseInfoPwrGroup OBJECT-GROUP + OBJECTS { + cpeExtMainPseUsedPower, + cpeExtMainPseRemainingPower + } + STATUS current + DESCRIPTION + "This is a collection of objects which provide + used and remaining power information for the PSE group." + ::= { cpeExtMIBGroups 18 } + +END + + |