summaryrefslogtreecommitdiff
path: root/MIBS/cisco/CISCOSB-EVENTS-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/cisco/CISCOSB-EVENTS-MIB')
-rw-r--r--MIBS/cisco/CISCOSB-EVENTS-MIB559
1 files changed, 559 insertions, 0 deletions
diff --git a/MIBS/cisco/CISCOSB-EVENTS-MIB b/MIBS/cisco/CISCOSB-EVENTS-MIB
new file mode 100644
index 0000000..26032a0
--- /dev/null
+++ b/MIBS/cisco/CISCOSB-EVENTS-MIB
@@ -0,0 +1,559 @@
+CISCOSB-EVENTS-MIB DEFINITIONS ::= BEGIN
+
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION, DisplayString,
+ TruthValue, RowStatus FROM SNMPv2-TC
+ switch001 FROM CISCOSB-MIB
+ Counter FROM RFC1155-SMI
+ InterfaceIndex, InterfaceIndexOrZero FROM IF-MIB
+ SnmpAdminString FROM SNMP-FRAMEWORK-MIB
+ RlSmartPortsMacroNameOrZero FROM CISCOSB-SMARTPORTS-MIB;
+
+rlEventsMib MODULE-IDENTITY
+ LAST-UPDATED "201009110000Z"
+ ORGANIZATION "Cisco Systems, Inc."
+
+ CONTACT-INFO
+ "Postal: 170 West Tasman Drive
+ San Jose , CA 95134-1706
+ USA
+
+
+ Website: Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
+
+ DESCRIPTION
+ "MTS events MIB."
+ REVISION "201009110000Z"
+ DESCRIPTION
+ "Initial revision."
+ ::= { switch001 150 }
+
+--
+-- rlEvents MIB
+--
+
+SmartPortType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Supported smart port types."
+ SYNTAX INTEGER {
+ unknown(1),
+ default(2),
+ printer(3),
+ desktop(4),
+ guest(5),
+ server(6),
+ host(7),
+ ip-camera(8),
+ ip-phone(9),
+ ip-phone-desktop(10),
+ switch(11),
+ router(12),
+ ap(13)
+}
+SmartPortMacroParameterName ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Smart macro parameter name."
+ SYNTAX DisplayString(SIZE(1..32))
+
+SmartPortMacroParameterValue ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Smart macro parameter value."
+ SYNTAX DisplayString(SIZE(1..80))
+
+SmartPortMacroType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Smart macro type - built-in or user-defined."
+ SYNTAX INTEGER {built-in(1), user-defined(2)}
+
+SmartPortMacroParameterOrder ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Smart macro parameter order."
+ SYNTAX INTEGER {single(1), first(2), middle(3), last(4)}
+
+ rlPortEvents OBJECT IDENTIFIER ::= { rlEventsMib 1}
+
+ rlAutoSmartPortAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled (1),
+ disabled (2),
+ controlled(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "disabled - Auto Smart port feature is administratively disabled.
+ enabled - Auto Smart port feature is administratively enabled.
+ controlled - Auto Smart port feature is administratively controlled by VOICE VLAN.
+ "
+ DEFVAL {controlled}
+ ::= { rlPortEvents 1 }
+
+ rlAutoSmartPortOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled (1),
+ disabled (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "disabled - Auto Smart port feature is operationally disabled.
+ enabled - Auto Smart port feature is operationally enabled.
+ "
+ DEFVAL {disabled}
+ ::= { rlPortEvents 2 }
+
+ rlAutoSmartPortLastVoiceVlanStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled (1),
+ disabled (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicated last status set by VOICE VLAN feature.
+ If rlAutoSmartPortAdminStatus has 'controlled' value then the value of this object is the same as rlAutoSmartPortOperStatus.
+
+ enabled - Auto Smart port feature should be operationally enabled, if rlAutoSmartPortAdminStatus has 'controlled' value.
+ disabled - Auto Smart port feature should be operationally disabled, if rlAutoSmartPortAdminStatus has 'controlled' value
+ "
+ DEFVAL {disabled}
+ ::= { rlPortEvents 3}
+
+ rlAutoSmartPortLastVoiceVlanId OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicated last VOICE VLAN ID set by VOICE VLAN feature."
+ ::= { rlPortEvents 4}
+
+ rlAutoSmartPortLearningProtocols OBJECT-TYPE
+ SYNTAX BITS {
+ cdp (0),
+ lldp (1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "cdp - Information about device type of neighboring devices(s) is learnt
+ via CDP (Cisco Discovery Protocol) advertisements.
+ lldp - Information about device type of neighboring devices(s) is learnt
+ via LLDP (Link Layer Discovery Protocol ) advertisements. "
+ ::= { rlPortEvents 5 }
+
+
+ rlAutoSmartPortTypesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlAutoSmartPortTypesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table is used to keep all the information related to a specific port type."
+ ::= { rlPortEvents 6 }
+
+ rlAutoSmartPortTypesEntry OBJECT-TYPE
+ SYNTAX RlAutoSmartPortTypesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry (conceptual row) in the rlAutoSmartPortTypesTable."
+ INDEX { rlAutoSmartPortTypesType }
+ ::= { rlAutoSmartPortTypesTable 1 }
+
+ RlAutoSmartPortTypesEntry ::= SEQUENCE {
+ rlAutoSmartPortTypesType SmartPortType,
+ rlAutoSmartPortTypeStatus INTEGER,
+ rlAutoSmartPortMacro RlSmartPortsMacroNameOrZero,
+ rlAutoSmartPortTypesRevertToDefaultMacro TruthValue,
+ rlAutoSmartPortTypesRevertToDefaultParams TruthValue,
+ rlAutoSmartPortTypesBuiltinMacro SmartPortMacroType
+
+
+ }
+
+ rlAutoSmartPortTypesType OBJECT-TYPE
+ SYNTAX SmartPortType
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Smart port type."
+ ::= { rlAutoSmartPortTypesEntry 1 }
+
+ rlAutoSmartPortTypeStatus OBJECT-TYPE
+ SYNTAX INTEGER { enabled(1), disabled(2), default(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Smart port type global status. "
+ ::= { rlAutoSmartPortTypesEntry 2 }
+
+ rlAutoSmartPortMacro OBJECT-TYPE
+ SYNTAX RlSmartPortsMacroNameOrZero
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Macro to be activated when a port is set to the smart port type indicated
+ by rlAutoSmartPortTypesType. The macro whose name is 'no_'<rlAutoSmartPortMacro>
+ is activated when a port ceases to be of this smart port type. "
+ ::= { rlAutoSmartPortTypesEntry 3 }
+
+
+ rlAutoSmartPortTypesRevertToDefaultMacro OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Setting this object will cause the smart port type macro associated with this smart port type
+ to revert to the default macro. "
+ ::= { rlAutoSmartPortTypesEntry 4 }
+
+ rlAutoSmartPortTypesRevertToDefaultParams OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Setting this object will cause the default smart port type parameter values associated with the built-in macro
+ of this smart port type to revert to their default values."
+ ::= { rlAutoSmartPortTypesEntry 5 }
+
+ rlAutoSmartPortTypesBuiltinMacro OBJECT-TYPE
+ SYNTAX SmartPortMacroType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the macro is built-in or user defined."
+ ::= { rlAutoSmartPortTypesEntry 6 }
+
+
+ rlAutoSmartPortMacrosParamTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlAutoSmartPortMacrosParamEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table is used to keep all the default parameter values related to a specific port type."
+ ::= { rlPortEvents 7 }
+
+ rlAutoSmartPortMacrosParamEntry OBJECT-TYPE
+ SYNTAX RlAutoSmartPortMacrosParamEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A parameter name & default value pair for a smart port type macro."
+ INDEX { rlAutoSmartPortTypesType, rlAutoSmartPortMacroType, IMPLIED rlAutoSmartPortMacrosParamName }
+ ::= { rlAutoSmartPortMacrosParamTable 1 }
+
+ RlAutoSmartPortMacrosParamEntry ::= SEQUENCE {
+ rlAutoSmartPortMacroType SmartPortMacroType,
+ rlAutoSmartPortMacrosParamName SmartPortMacroParameterName,
+ rlAutoSmartPortMacrosParamOrder SmartPortMacroParameterOrder,
+ rlAutoSmartPortMacrosParamValue SmartPortMacroParameterValue
+
+ }
+
+ rlAutoSmartPortMacroType OBJECT-TYPE
+ SYNTAX SmartPortMacroType
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Macro type - built-in or user defined."
+ ::= { rlAutoSmartPortMacrosParamEntry 1 }
+
+ rlAutoSmartPortMacrosParamName OBJECT-TYPE
+ SYNTAX SmartPortMacroParameterName
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Name of the parameter to be supplied at smart port macro activation. "
+ ::= { rlAutoSmartPortMacrosParamEntry 2 }
+
+ rlAutoSmartPortMacrosParamOrder OBJECT-TYPE
+ SYNTAX SmartPortMacroParameterOrder
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Setting this object to 'first' instructs the system to erase all previous information associated
+ with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row.
+ Setting this object to 'middle' instructs the system to wait for further parameters.
+ Setting this object to 'last' informs the system that no further parameters will be sent and
+ therefore it can start the macro or builtin parameters change process.
+ Setting this object to 'single' instructs the system to erase all previous information associated
+ with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row and
+ informs the system that no further parameters will be sent and therefore it can start macro or builtin
+ parameters change process."
+ ::= { rlAutoSmartPortMacrosParamEntry 3 }
+
+
+ rlAutoSmartPortMacrosParamValue OBJECT-TYPE
+ SYNTAX SmartPortMacroParameterValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Default value of the parameter to be supplied at smart port macro activation. "
+ ::= { rlAutoSmartPortMacrosParamEntry 4 }
+
+
+
+ rlAutoSmartPortPortsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlAutoSmartPortPortsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table is used to keep all the auto smart port information related to a specific port."
+ ::= { rlPortEvents 8 }
+
+ rlAutoSmartPortPortsEntry OBJECT-TYPE
+ SYNTAX RlAutoSmartPortPortsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry (conceptual row) in the rlAutoSmartPortPortsTable."
+ INDEX { rlAutoSmartPortPort }
+ ::= { rlAutoSmartPortPortsTable 1 }
+
+ RlAutoSmartPortPortsEntry ::= SEQUENCE {
+ rlAutoSmartPortPort InterfaceIndex,
+ rlAutoSmartPortPortStatus INTEGER,
+ rlAutoSmartPortPortType SmartPortType,
+ rlAutoSmartPortPersistency INTEGER,
+ rlAutoSmartPortLearntPortType SmartPortType,
+ rlAutoSmartPortPortAcquiringType INTEGER,
+ rlAutoSmartPortLastActivatedMacro RlSmartPortsMacroNameOrZero,
+ rlAutoSmartPortFailedCommandNumber INTEGER,
+ rlAutoSmartPortSetLearntPortType TruthValue
+
+
+ }
+
+ rlAutoSmartPortPort OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The port to which the smartport information is associated."
+ ::= { rlAutoSmartPortPortsEntry 1 }
+
+ rlAutoSmartPortPortStatus OBJECT-TYPE
+ SYNTAX INTEGER {enabled(1), disabled(2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether auto smart port feature is enabled or not on this port."
+ DEFVAL { enabled }
+ ::= { rlAutoSmartPortPortsEntry 2 }
+
+ rlAutoSmartPortPortType OBJECT-TYPE
+ SYNTAX SmartPortType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Smart port type associated with this port. If set by user, the port will retain
+ the smart port type at link down, link not present and reboot events."
+ DEFVAL { default }
+ ::= { rlAutoSmartPortPortsEntry 3 }
+
+
+ rlAutoSmartPortPersistency OBJECT-TYPE
+ SYNTAX INTEGER {persistent(1), not-persistent(2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If set to persistent then, if the system concludes, according to
+ the information learnt there is no relevant device connected to the port,
+ the rlAutoSmartPortPortType will not be changed (as if the user set this
+ rlAutoSmartPortPortType himself), except on learning another rlAutoSmartPortPortType."
+ DEFVAL { not-persistent }
+ ::= { rlAutoSmartPortPortsEntry 4 }
+
+
+ rlAutoSmartPortLearntPortType OBJECT-TYPE
+ SYNTAX SmartPortType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Smart port type learnt via the learning protocols. This value will
+ be different from rlAutoSmartPortPortType only if rlAutoSmartPortPortType
+ was manually configured (i.e. if the value of
+ rlAutoSmartPortPortAcquiringType is 'configuration'). The value of the object
+ is used to set the value of rlAutoSmartPortPortType
+ if the user removes the configuration."
+ DEFVAL { default }
+ ::= { rlAutoSmartPortPortsEntry 5 }
+
+ rlAutoSmartPortPortAcquiringType OBJECT-TYPE
+ SYNTAX INTEGER {default(1), configuration(2), persistency(3), learning(4)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the way that the value of rlAutoSmartPortPortType was acquired. This object can be
+ set only during configuration download."
+ ::= { rlAutoSmartPortPortsEntry 6 }
+
+ rlAutoSmartPortLastActivatedMacro OBJECT-TYPE
+ SYNTAX RlSmartPortsMacroNameOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates macro name of last activated macro or 'no macro' if no macro was run."
+ ::= { rlAutoSmartPortPortsEntry 7 }
+
+ rlAutoSmartPortFailedCommandNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates number of command (starting with 1) that caused the macro
+ failure or 0 if the macro succeeded or no macro was run."
+ ::= { rlAutoSmartPortPortsEntry 8 }
+
+ rlAutoSmartPortSetLearntPortType OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Instructs the system to set the port type to the learnt port type."
+ ::= { rlAutoSmartPortPortsEntry 9 }
+
+ rlAutoSmartPortParamsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlAutoSmartPortActionParamsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table optionally determines the parameter values for the macro that is activated when the smartport type is
+ manually changed for a specific port or trunk via the rlAutoSmartPortPortType object."
+ ::= { rlPortEvents 9 }
+
+ rlAutoSmartPortParamsEntry OBJECT-TYPE
+ SYNTAX RlAutoSmartPortActionParamsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A parameter name & immediate value."
+ INDEX { rlAutoSmartPortIfIndex, IMPLIED rlAutoSmartPortParamName }
+ ::= { rlAutoSmartPortParamsTable 1 }
+
+ RlAutoSmartPortActionParamsEntry ::= SEQUENCE {
+ rlAutoSmartPortIfIndex InterfaceIndex,
+ rlAutoSmartPortParamName SmartPortMacroParameterName,
+ rlAutoSmartPortParamOrder SmartPortMacroParameterOrder,
+ rlAutoSmartPortParamValue SmartPortMacroParameterValue
+
+ }
+
+ rlAutoSmartPortIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The port or trunk that this entry is associated with. "
+ ::= { rlAutoSmartPortParamsEntry 1 }
+
+ rlAutoSmartPortParamName OBJECT-TYPE
+ SYNTAX SmartPortMacroParameterName
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Name of the parameter whose value must be supplied at a smart port macro activation. "
+ ::= { rlAutoSmartPortParamsEntry 2 }
+
+ rlAutoSmartPortParamOrder OBJECT-TYPE
+ SYNTAX SmartPortMacroParameterOrder
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Setting this object to 'first' instructs the system to erase all previous information associated
+ with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row.
+ Setting this object to 'middle' instructs the system to wait for further parameters.
+ Setting this object to 'last' informs the system that no further parameters will be sent and
+ therefore it can start applying the smartport type.
+ Setting this object to 'single' instructs the system to erase all previous information associated
+ with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row and
+ informs the system that no further parameters will be sent and informs the system that no further parameters will be sent and
+ therefore it can start applying the smartport type."
+ ::= { rlAutoSmartPortParamsEntry 3 }
+
+ rlAutoSmartPortParamValue OBJECT-TYPE
+ SYNTAX SmartPortMacroParameterValue
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Value of the parameter whose value must be supplied at a smart port macro activation. "
+ ::= { rlAutoSmartPortParamsEntry 4 }
+
+
+
+ rlAutoSmartTrunkRefreshTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RlAutoSmartTrunkRefreshEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Setting this object causes running the SmartPort macros of the
+ following types: router, switch and ap. This operation is called the trunk refresh operation."
+ ::= { rlPortEvents 10 }
+
+
+ rlAutoSmartTrunkRefreshEntry OBJECT-TYPE
+ SYNTAX RlAutoSmartTrunkRefreshEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry (conceptual row) in the rlAutoSmartTrunkRefreshTable."
+ INDEX { rlAutoSmartTrunkRefreshSmartPortType, rlAutoSmartTrunkRefreshIfIndex }
+ ::= { rlAutoSmartTrunkRefreshTable 1 }
+
+ RlAutoSmartTrunkRefreshEntry ::= SEQUENCE {
+ rlAutoSmartTrunkRefreshSmartPortType INTEGER,
+ rlAutoSmartTrunkRefreshIfIndex InterfaceIndexOrZero,
+ rlAutoSmartTrunkRefreshRowStatus RowStatus
+ }
+
+ rlAutoSmartTrunkRefreshSmartPortType OBJECT-TYPE
+ SYNTAX INTEGER {default(1), switch(11), router(12), ap(13)}
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "If not default the trunk refresh operation will be carried out on all ports of this smart port type if
+ rlAutoSmartTrunkRefreshIfIndex is nonzero, or on the port specifed by rlAutoSmartTrunkRefreshIfIndex if it's type
+ matches the given this smart port type (if not matching a wrong-value error will be return).
+ If default the trunk refresh operation will be carried out on all ports of router, switch and ap smart port type if
+ rlAutoSmartTrunkRefreshIfIndex is nonzero, or on the port specifed by rlAutoSmartTrunkRefreshIfIndex."
+ ::= { rlAutoSmartTrunkRefreshEntry 1 }
+
+ rlAutoSmartTrunkRefreshIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "If 0 the trunk refresh operation will be carried out on all ports of the smart port type as specified in the
+ rlAutoSmartTrunkRefreshSmartPortType. If nonzero the trunk refresh operation will be carried out
+ on the specified port, if rlAutoSmartTrunkRefreshSmartPortType is default or matches the smart port type of
+ the specified port. Any other case will result in a wrong-value error."
+ ::= { rlAutoSmartTrunkRefreshEntry 2 }
+
+ rlAutoSmartTrunkRefreshRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Since this an action table only createAndGo will be accepted and the conceptual row will vanish immediately
+ after the action execution."
+ ::= { rlAutoSmartTrunkRefreshEntry 3 }
+
+
+ rlAutoSmartBusy OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If true indicates that the autosmartports system is temporarily busy performing a multiport
+ operation and therefore can not service management requests for the time-being."
+ ::= { rlPortEvents 11 }
+
+
+
+ END