diff options
Diffstat (limited to 'MIBS/cisco/OLD-CISCO-SYS-MIB')
| -rw-r--r-- | MIBS/cisco/OLD-CISCO-SYS-MIB | 1043 |
1 files changed, 1043 insertions, 0 deletions
diff --git a/MIBS/cisco/OLD-CISCO-SYS-MIB b/MIBS/cisco/OLD-CISCO-SYS-MIB new file mode 100644 index 0000000..fcf85c0 --- /dev/null +++ b/MIBS/cisco/OLD-CISCO-SYS-MIB @@ -0,0 +1,1043 @@ +-- ***************************************************************** +-- OLD-CISCO-SYS-MIB.my: Cisco System MIB file +-- +-- July 1994, Jeffrey T. Johnson +-- +-- Copyright (c) 1994-1996 by cisco Systems, Inc. +-- All rights reserved. +-- +-- ***************************************************************** +-- +-- Prior to 10.2, Cisco's lsystem mib group contained a curious +-- assortment of mib objects. For 10.2, in order to allow similar +-- objects to be compiled separately with the mib compiler, the +-- lsystem group was separated into an envmon group (lenv), a cpu +-- group (lcpu), a memory group (lmem), and a system group (lsystem). +-- In order to preserve the OBJECT IDENTIFIERS from release 10.1 to +-- 10.2, however, all four groups are still based at { local 1 }. +-- This is fine from the mib compiler point-of-view, but causes +-- problems for some test tools which don't like the fact that +-- lsystem, lenv, lmem, and lcpu all have the same OBJECT IDENTIFIER. +-- In order to work around this problem, this file exists which +-- is a combination of the four 10.2 "system" mibs, with everything +-- falling under the lsystem group (as it did in 10.1). +-- +-- This mib should only be used as a replacement for the four separate +-- system mibs (OLD-CISCO-CPU.my, OLD-CISCO-ENVMON-MIB.my, +-- OLD-CISCO-MEMORY-MIB.my, OLD-CISCO-SYSTEM-MIB.my) in test tool +-- environments. The aforementioned mibs should always be used in +-- code generation + + OLD-CISCO-SYS-MIB DEFINITIONS ::= BEGIN + + IMPORTS + IpAddress + FROM RFC1155-SMI + OBJECT-TYPE + FROM RFC-1212 + DisplayString + FROM RFC1213-MIB + local + FROM CISCO-SMI; + + lsystem OBJECT IDENTIFIER ::= { local 1 } + + -- Local Variable Section + + -- This section describes the local variables within the cisco + -- product line. Groups may or may not be present depending + -- on the software options present in the managed device. + + + -- Local System Group + + -- This group is present in all products. + + romId OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable contains a printable octet + string which contains the System Bootstrap + description and version identification." + ::= { lsystem 1 } + + whyReload OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable contains a printable octet + string which contains the reason why the + system was last restarted." + ::= { lsystem 2 } + + hostName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable represents the name of the + host in printable ascii characters." + ::= { lsystem 3 } + + domainName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable is the domain portion of the + domain name of the host." + ::= { lsystem 4 } + + authAddr OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable contains the last SNMP + authorization failure IP address." + ::= { lsystem 5 } + + bootHost OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the IP address of the host that + supplied the currently running software." + ::= { lsystem 6 } + + ping OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS obsolete + DESCRIPTION + "The ping mib object is obsolete as of IOS 10.2 + It has been superseded by the Cisco Ping MIB" + ::= { lsystem 7 } + + freeMem OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS obsolete + DESCRIPTION + "The freeMem mib object is obsolete as of IOS 11.1 + It has been replaced with the cisco memory pool mib" + ::= { lsystem 8 } + + bufferElFree OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of free buffer + elements." + ::= { lsystem 9 } + + bufferElMax OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the maximum number of buffer + elements." + ::= { lsystem 10 } + + bufferElHit OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of buffer element hits." + ::= { lsystem 11 } + + bufferElMiss OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of buffer element + misses." + ::= { lsystem 12 } + + bufferElCreate OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of buffer element + creates." + ::= { lsystem 13 } + + bufferSmSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the size of small buffers." + ::= { lsystem 14 } + + bufferSmTotal OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the total number of small buffers." + ::= { lsystem 15 } + + bufferSmFree OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of free small buffers." + ::= { lsystem 16 } + + bufferSmMax OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the maximum number of small + buffers." + ::= { lsystem 17 } + + bufferSmHit OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of small buffer hits." + ::= { lsystem 18 } + + bufferSmMiss OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of small buffer misses." + ::= { lsystem 19 } + + bufferSmTrim OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of small buffer trims." + ::= { lsystem 20 } + + bufferSmCreate OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of small buffer + creates." + ::= { lsystem 21 } + + bufferMdSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the size of medium buffers." + ::= { lsystem 22 } + + bufferMdTotal OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the total number of medium + buffers." + ::= { lsystem 23 } + + bufferMdFree OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of free medium buffers." + ::= { lsystem 24 } + + bufferMdMax OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the maximum number of medium + buffers." + ::= { lsystem 25 } + + bufferMdHit OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of medium buffer hits." + ::= { lsystem 26 } + + bufferMdMiss OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of medium buffer + misses." + ::= { lsystem 27 } + + bufferMdTrim OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of medium buffer trims." + ::= { lsystem 28 } + + bufferMdCreate OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of medium buffer + creates." + ::= { lsystem 29 } + + bufferBgSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the size of big buffers." + ::= { lsystem 30 } + + bufferBgTotal OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the total number of big buffers." + ::= { lsystem 31 } + + bufferBgFree OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of free big buffers." + ::= { lsystem 32 } + + bufferBgMax OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the maximum number of big buffers." + ::= { lsystem 33 } + + bufferBgHit OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of big buffer hits." + ::= { lsystem 34 } + + bufferBgMiss OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of big buffer misses." + ::= { lsystem 35 } + + bufferBgTrim OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of big buffer trims." + ::= { lsystem 36 } + + bufferBgCreate OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of big buffer creates." + ::= { lsystem 37 } + + bufferLgSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the size of large buffers." + ::= { lsystem 38 } + + bufferLgTotal OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the total number of large buffers." + ::= { lsystem 39 } + + bufferLgFree OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of free large buffers." + ::= { lsystem 40 } + + bufferLgMax OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the maximum number of large + buffers." + ::= { lsystem 41 } + + bufferLgHit OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of large buffer hits." + ::= { lsystem 42 } + + bufferLgMiss OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of large buffer misses." + ::= { lsystem 43 } + + bufferLgTrim OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of large buffer trims." + ::= { lsystem 44 } + + bufferLgCreate OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of large buffer + creates." + ::= { lsystem 45 } + + bufferFail OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Count of the number of buffer allocation + failures." + ::= { lsystem 46 } + + bufferNoMem OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Count of the number of buffer create + failures due to no free memory." + ::= { lsystem 47 } + + netConfigAddr OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Holds the address of the host that supplied + the network-confg file." + ::= { lsystem 48 } + + netConfigName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Holds the name of the network configuration + file." + ::= { lsystem 49 } + + netConfigSet OBJECT-TYPE + SYNTAX DisplayString + ACCESS write-only + STATUS mandatory + DESCRIPTION + "Cause the loading of a new network-confg + file using TFTP." + ::= { lsystem 50 } + + hostConfigAddr OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-only + STATUS obsolete + DESCRIPTION + "Contains the address of the host that + provided the host-config file." + ::= { lsystem 51 } + + hostConfigName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS obsolete + DESCRIPTION + "Contains the name of the last configured + host-confg file." + ::= { lsystem 52 } + + hostConfigSet OBJECT-TYPE + SYNTAX DisplayString + ACCESS write-only + STATUS obsolete + DESCRIPTION + "Cause the loading of a new host-confg file + using TFTP." + ::= { lsystem 53 } + + writeMem OBJECT-TYPE + SYNTAX INTEGER + ACCESS write-only + STATUS mandatory + DESCRIPTION + "Write configuration into non-volatile memory + / erase config memory if 0." + ::= { lsystem 54 } + + writeNet OBJECT-TYPE + SYNTAX DisplayString + ACCESS write-only + STATUS mandatory + DESCRIPTION + "Write configuration to host using TFTP." + ::= { lsystem 55 } + + busyPer OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "CPU busy percentage in the last 5 second + period. Not the last 5 realtime seconds but + the last 5 second period in the scheduler." + ::= { lsystem 56 } + + avgBusy1 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "1 minute exponentially-decayed moving + average of the CPU busy percentage." + ::= { lsystem 57 } + + avgBusy5 OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "5 minute exponentially-decayed moving + average of the CPU busy percentage." + ::= { lsystem 58 } + + idleCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "cisco internal variable. not to be used" + ::= { lsystem 59 } + + idleWired OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "cisco internal variable. not to be used" + ::= { lsystem 60 } + + ciscoContactInfo OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "cisco's name and address" + ::= { lsystem 61 } + + bufferHgSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the size of huge buffers." + ::= { lsystem 62 } + + bufferHgTotal OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the total number of huge buffers." + ::= { lsystem 63 } + + bufferHgFree OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of free huge buffers." + ::= { lsystem 64 } + + bufferHgMax OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the maximum number of huge + buffers." + ::= { lsystem 65 } + + bufferHgHit OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of huge buffer hits." + ::= { lsystem 66 } + + bufferHgMiss OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of huge buffer misses." + ::= { lsystem 67 } + + bufferHgTrim OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of huge buffer trims." + ::= { lsystem 68 } + + bufferHgCreate OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Contains the number of huge buffer creates." + ::= { lsystem 69 } + + netConfigProto OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Holds the protocol that supplied the + network-confg file." + ::= { lsystem 70 } + + hostConfigProto OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Holds the protocol that supplied the host- + confg file." + ::= { lsystem 71 } + + sysConfigAddr OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Holds the address of the host that supplied + the system boot image." + ::= { lsystem 72 } + + sysConfigName OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Holds the name of the system boot image." + ::= { lsystem 73 } + + sysConfigProto OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Holds the protocol that supplied the system + boot image." + ::= { lsystem 74 } + + sysClearARP OBJECT-TYPE + SYNTAX INTEGER + ACCESS write-only + STATUS mandatory + DESCRIPTION + "Perform a clearing of the entire ARP cache + and invalidation of route caches." + ::= { lsystem 75 } + + sysClearInt OBJECT-TYPE + SYNTAX INTEGER + ACCESS write-only + STATUS mandatory + DESCRIPTION + "Clear interface given IfIndex as value." + ::= { lsystem 76 } + + envPresent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Is there an environmental monitor card in + this box?, 0 - No, 1-AGS card present, wrong + firmware, 2-AGS CARD present, firmware ok, + 3-7000 support" + ::= { lsystem 77 } + + envTestPt1Descr OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of the test point 1. Typically + ambient air or the temperature of air + entering the router" + ::= { lsystem 78 } + + envTestPt1Measure OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Current value of test point 1. Typically a + temperature in centigrade." + ::= { lsystem 79 } + + envTestPt2Descr OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of the test point 2. Typically + airflow or the temperature of air leaving the + router" + ::= { lsystem 80 } + + envTestPt2Measure OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Current value of test point 2. Typically a + temperature in centigrade." + ::= { lsystem 81 } + + envTestPt3Descr OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of the test point 3. Typically + +5 volt" + ::= { lsystem 82 } + + envTestPt3Measure OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Current value of test point 3. Typically the + value in millivolts of the +5v supply" + ::= { lsystem 83 } + + envTestPt4Descr OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of the test point 4. Typically + +12 volt" + ::= { lsystem 84 } + + envTestPt4Measure OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Current value of test point 4. Typically the + value in millivolts of the +12v supply" + ::= { lsystem 85 } + + envTestPt5Descr OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of the test point 5. Typically + -12 volt" + ::= { lsystem 86 } + + envTestPt5Measure OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Current value of test point 5. Typically the + value in millivolts of the -12v supply" + ::= { lsystem 87 } + + envTestPt6Descr OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of the test point 6. Typically + -5 volt" + ::= { lsystem 88 } + + envTestPt6Measure OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Current value of test point 6. Typically the + value in millivolts of the -5v supply" + ::= { lsystem 89 } + + envTestPt1MarginVal OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Value at which the router will shutdown. + Typically the ambient air temperature that + will shut the router down. (e.g. 43)" + ::= { lsystem 90 } + + envTestPt2MarginVal OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Value at which the router will shutdown. + Typically the airflow air temperature that + will shut the router down. (e.g. 58)" + ::= { lsystem 91 } + + envTestPt3MarginPercent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "+/- Percentage that will shut the router + down, (e.g. 10%) typically +5 volt" + ::= { lsystem 92 } + + envTestPt4MarginPercent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "+/- Percentage that will shut the router + down, (e.g. 15%) typically +12 volt" + ::= { lsystem 93 } + + envTestPt5MarginPercent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "+/- Percentage that will shut the router + down, (e.g. 15%) typically -12 volt" + ::= { lsystem 94 } + + envTestPt6MarginPercent OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "+/- Percentage that will shut the router + down, (e.g. 10%) typically -5 volt" + ::= { lsystem 95 } + + envTestPt1last OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Value of TestPt1 when last shutdown + occurred." + ::= { lsystem 96 } + + envTestPt2last OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Value of TestPt2 when last shutdown + occurred." + ::= { lsystem 97 } + + envTestPt3last OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Value of TestPt3 when last shutdown + occurred." + ::= { lsystem 98 } + + envTestPt4last OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Value of TestPt4 when last shutdown + occurred." + ::= { lsystem 99 } + + envTestPt5last OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Value of TestPt5 when last shutdown + occurred." + ::= { lsystem 100 } + + envTestPt6last OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Value of TestPt6 when last shutdown + occurred." + ::= { lsystem 101 } + + envTestPt1warn OBJECT-TYPE + SYNTAX INTEGER { + warning(1), + noWarning(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Is this test point at a warning level?" + ::= { lsystem 102 } + + envTestPt2warn OBJECT-TYPE + SYNTAX INTEGER { + warning(1), + noWarning(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Is this test point at a warning level?" + ::= { lsystem 103 } + + envTestPt3warn OBJECT-TYPE + SYNTAX INTEGER { + warning(1), + noWarning(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Is this test point at a warning level?" + ::= { lsystem 104 } + + envTestPt4warn OBJECT-TYPE + SYNTAX INTEGER { + warning(1), + noWarning(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Is this test point at a warning level?" + ::= { lsystem 105 } + + envTestPt5warn OBJECT-TYPE + SYNTAX INTEGER { + warning(1), + noWarning(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Is this test point at a warning level?" + ::= { lsystem 106 } + + envTestPt6warn OBJECT-TYPE + SYNTAX INTEGER { + warning(1), + noWarning(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Is this test point at a warning level?" + ::= { lsystem 107 } + + envFirmVersion OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Description of Environmental Card firmware" + ::= { lsystem 108 } + + envTechnicianID OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Technician ID" + ::= { lsystem 109 } + + envType OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of environmental card" + ::= { lsystem 110 } + + envBurnDate OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The calibration / burn in date" + ::= { lsystem 111 } + + envSerialNumber OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "Serial Number of environmental monitor card" + ::= { lsystem 112 } + + + END |