+-- Copyright (c) 2004-2019 New H3C Tech. Co., Ltd. All rights reserved.
+--
+-- Description: Power over ethernet extend MIB
+-- Reference: POWER-ETHERNET-MIB
+-- Version: V1.7
+-- History:
+-- V1.0 2004-07-24 Created by Gaolong
+-- V1.1 2004-09-08 Update file by Gaolong for some syntax errors.
+-- V1.2 2004-11-19 Update file by liuhongxu for poe need.
+-- add hh3cMainPsePriorityMode¡¢hh3cPsePowerMaxValue¡¢
+-- hh3cpsePDChangNotification adjust the objects' sequence of
+-- hh3cPsePortTable and hh3cMainPseTable add the description
+-- of MANDATORY-GROUPS in hh3cPseCompliance.
+-- V1.3 2004-12-16 Update file by liuhongxu for poe profile
+-- add hh3cPsePortProfile, hh3cPseProfilesTable
+-- change the name of hh3cPseProfileIndex add
+-- hh3cPseProfileApplyNum. adjust the format of this mib.
+-- V1.4 2005-03-29 Update file by Wangzhaoyan for poe pow need.
+-- add hh3cPOEPowerObjects, hh3cPOEThresholdLimitObjs,
+-- hh3cPOESupModuleInfoObjs, hh3cPOEDCOutStateObjects,
+-- hh3cPOEDCDCOutInfoObjects, hh3cPOEACSwitchStateModuleObjs,
+-- hh3cPOEInCurStateObjects, hh3cPOEAlarmStateObjects and the
+-- sub-nodes. add 17 traps change the node name from
+-- hh3cpsePDChangNotification to hh3cpsePDChangeNotification
+-- change some detail as the suggestion from Wangyingxia and
+-- Yangyang. adjust the format of this mib.
+-- V1.5 2005-11-21 Update file by Liweizhen for controling the power-management
+-- policy of PSE or PD. Add hh3cPsePolicyMode, hh3cPDPolicyMode,
+-- hh3cMainPsePowerPriority.
+-- Delete some description of hh3cPsePortProfileIndex node.
+-- Change the description of hh3cPseProfilePowerMode node.
+-- Change SYNTAX OCTET STRING range for the following nodes:
+-- hh3cPOEPowerType, hh3cPOESupervisionModuleName,
+-- hh3cPOESMFactorName, hh3cPOEModuleHardVerInfo.
+-- Adjust the format of this mib.
+-- V1.6 2015-07-21 Update file by Fangliwen for profile power limit.
+-- Change the syntax of hh3cPseProfilePowerLimit node.
+-- V1.7 2019-5-23 Update file for PoE-AI. Add the following nodes:
+-- hh3cPsePDDisableNotification,hh3cPsePortGroupIndex,
+-- hh3cPsePortIndex and hh3cPsePortDisableInfo.
+-- =================================================================
+HH3C-POWER-ETH-EXT-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ hh3cCommon
+ FROM HH3C-OID-MIB
+ pethPsePortGroupIndex, pethPsePortIndex,
+ pethMainPseGroupIndex, pethPsePortDetectionStatus
+ FROM POWER-ETHERNET-MIB
+ OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
+ FROM SNMPv2-CONF
+ Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
+ FROM SNMPv2-SMI
+ DisplayString, RowStatus, TEXTUAL-CONVENTION
+ FROM SNMPv2-TC;
+
+
+hh3cPowerEthernetExt MODULE-IDENTITY
+ LAST-UPDATED "201905230000Z" -- May 23, 2019 at 00:00 GMT
+
+ ORGANIZATION
+ "New H3C Tech. Co., Ltd."
+ CONTACT-INFO
+ "Platform Team New H3C Tech. Co., Ltd.
+ Hai-Dian District Beijing P.R. China
+ http://www.h3c.com
+ Zip:100085
+ "
+ DESCRIPTION
+ "Description."
+ REVISION "201905230000Z"
+ DESCRIPTION
+ "Add the following nodes:
+ hh3cPsePDDisableNotification,hh3cPsePortGroupIndex,
+ hh3cPsePortIndex and hh3cPsePortDisableInfo."
+ REVISION "201507250000Z"
+ DESCRIPTION
+ "The initial version of this MIB module."
+ ::= { hh3cCommon 14 }
+
+
+--
+-- Node definitions
+--
+
+hh3cPsePortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cPsePortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The indexing scheme is taken form that used by
+ the IETF Power MIB. The same indexing scheme is
+ used to give continuity in behaviour between
+ that standard and this extensions definitioin."
+ ::= { hh3cPowerEthernetExt 1 }
+
+
+hh3cPsePortEntry OBJECT-TYPE
+ SYNTAX Hh3cPsePortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The pethPsePortGroupIndex is imported from the IETF Power MIB
+ and uniquely identifies the group containing the port to which
+ power ethernet PSE is connected. Group means (box in the stack,
+ module in a rack).
+
+ The pethPsePortPowerIndex is imported from the IETF Power MIB
+ and uniquely identifies the power ethernet PSE port within group
+ pethPseGroupIndex to which the power Ethernet PSE entry is
+ connected. This value will match the local port number on a
+ switch."
+ INDEX { pethPsePortGroupIndex, pethPsePortIndex }
+ ::= { hh3cPsePortTable 1 }
+
+
+Hh3cPsePortEntry ::=
+ SEQUENCE {
+ hh3cPsePortFaultDescription
+ DisplayString,
+ hh3cPsePortPeakPower
+ Integer32,
+ hh3cPsePortAveragePower
+ Integer32,
+ hh3cPsePortCurrentPower
+ Integer32,
+ hh3cPsePortPowerLimit
+ Integer32,
+ hh3cPsePortProfileIndex
+ Integer32
+ }
+
+hh3cPsePortFaultDescription OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The object supports the fault category of the IETF Power MIB [1]
+ pethPsePortDetectionStatus object. A textual description
+ containing more information about the nature of this fault is
+ provided by this object. Typically this will detail the precise
+ PoE hardware state which is causing the pethPsePortDetectionStatus
+ object to be in the 'fault' state.
+ It is a DisplayString of up to 255 characters."
+ ::= { hh3cPsePortEntry 2 }
+
+
+hh3cPsePortPeakPower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The object specifies the peak power which has been consumed by
+ the port. It is defined as the highest measured value of power
+ in milliWatts that has been consumed by the port. Its value
+ is only reset when link is lost, the port is PoE disabled or
+ when it is manually reset by the user asspecified below.
+ It is a read/write integer value with units of milliWatts.
+ Writing a value of zero to this object resets its value
+ to zero. Writing any other value to this object has no
+ effect on its value and an error is returned."
+ ::= { hh3cPsePortEntry 3 }
+
+
+hh3cPsePortAveragePower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The object specifies the average power which has been consumed
+ by the port. This object is a read/write integer value with
+ units of milliWatts. Writing a value of zero to this object
+ resets its value to zero. Writing any other value to this
+ object has no effect on its value and an error is returned."
+ ::= { hh3cPsePortEntry 4 }
+
+
+hh3cPsePortCurrentPower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object specifies the power currently being consumed by the port.
+ It is a read only integer value with units of milliWatts."
+ ::= { hh3cPsePortEntry 5 }
+
+
+hh3cPsePortPowerLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The object specifies the power limit set for this port.
+ The PSE will not supply more than this level of power to the
+ specified port.
+ It is a read/write integer value with units of milliWatts."
+ ::= { hh3cPsePortEntry 6 }
+
+hh3cPsePortProfileIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the power profile which is currently associated
+ with this port. This object references the corresponding
+ hh3cPseProfileIndex object in the power profiles table. A
+ value of zero is a special case and indicates that no
+ power profile is currently associated with this port. When
+ hh3cPseProfileIndex is set to an index of existent profile,
+ pethPsePortPowerPairs, pethPsePortPowerPriority,
+ pethPsePortAdminEnable and hh3cPsePortPowerLimit will be
+ set to the same as corresponding value. PethPsePortPowerPairs,
+ pethPsePortPowerPriority and pethPsePortAdminEnable are objects
+ of rfc3621-Power-Ethernet.mib."
+ ::= { hh3cPsePortEntry 7 }
+
+
+hh3cMainPseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cMainPseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { hh3cPowerEthernetExt 2 }
+
+
+hh3cMainPseEntry OBJECT-TYPE
+ SYNTAX Hh3cMainPseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The pethMainPseGroupIndex is imported from the IETF Power MIB
+ and uniquely identifies the group containing the port to which
+ power ethernet PSE is connected. Group means (box in the stack,
+ module in a rack) and the value 1 MUST be used for non-modular
+ devices."
+ INDEX { pethMainPseGroupIndex }
+ ::= { hh3cMainPseTable 1 }
+
+
+Hh3cMainPseEntry ::=
+ SEQUENCE {
+ hh3cMainPsePowerLimit
+ Integer32,
+ hh3cMainPseAveragePower
+ Integer32,
+ hh3cMainPsePeakPower
+ Integer32,
+ hh3cMainGuaranteedPowerRemaining
+ Integer32,
+ hh3cMainPsePriorityMode
+ INTEGER,
+ hh3cMainPseLegacy
+ INTEGER,
+ hh3cMainPsePowerPriority
+ INTEGER
+ }
+
+hh3cMainPsePowerLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The object specifies the power limit set for the unit as a whole.
+ The PoE unit will already have a nominal power defined by the
+ IETF Power MIB [1] pethMainPsePower object. This OPTIONAL object
+ specifies a further limit to this nominal power value. This may
+ be useful to control the thermals of the unit, or for internal
+ testing purposes. One possible use for this object may be to lower
+ the power consumption of the unit if one or more of the internal
+ fans have broken. It is a read/write integer value with units of
+ Watts (note - Watts is chosen instead of milliWatts here since
+ the IETF Power MIB [1] measures unit based parameters, such as
+ the pethMainPsePower object, in units of Watts)."
+ ::= { hh3cMainPseEntry 1 }
+
+
+hh3cMainPseAveragePower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The object specifies the average power which has been consumed
+ by the port. It is a read/write integer value with units of
+ Watts (note - Watts is chosen instead of milliWatts here since
+ the IETF Power MIB [1] measures unit based parameters, such as
+ the pethMainPsePower object, in units of Watts). Writing a value
+ of zero to this object resets its value to zero. Writing any
+ other value to this object has no effect on its value and an error
+ is returned."
+ ::= { hh3cMainPseEntry 2 }
+
+
+hh3cMainPsePeakPower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The object specifies the peak power which has been consumed for PoE.
+ It is defined as the highest measured value of power in milliWatts
+ that has been consumed at any one point in time by the sum of the PoE
+ ports. Its value is only reset when the unit is powered on or when
+ it is manually reset by the user as specifiedbelow. It is a read/write
+ integer value with units of Watts (note - Watts is chosen instead of
+ milliWatts here since the IETF Power MIB [1] measures unit based
+ parameters, such as the pethMainPsePower object, in units of Watts).
+ Writing a value of zero to this object resets its value to zero.
+ Writing any other value to this object has noeffect on its value
+ and an error is returned."
+ ::= { hh3cMainPseEntry 3 }
+
+
+hh3cMainGuaranteedPowerRemaining OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object specifies the amount of power remaining in the guaranteed
+ power pool. Each time a port is placed into guaranteed mode it
+ reserves a set amount of power out of the total guaranteed power
+ pool for the system. This intention of this object is to give the
+ client of this MIB (whether that be the CLI or the Web interface or
+ the end user) an indication of how many ports can still be placed
+ into guaranteed mode. It is a read only integer value with units of
+ Watts(note - Watts is chosen instead of milliWatts here since the
+ IETF Power MIB [1] measures unit based parameters,such as the
+ pethMainPsePower object, in units of Watts)."
+ ::= { hh3cMainPseEntry 4 }
+
+
+hh3cMainPsePriorityMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ disconnection(0),
+ non-disconnection(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Describes or controls the priority mode on slot which must be
+ enabled firstly. When a new board is inserted, and the power is
+ over-load, a value of disconnection(0) means that the power will
+ stop supply to the low priority slot ; A value of non-disconnection(1)
+ means that the slot still supply when a new board is inserted, and
+ the power is over-load too."
+ ::= { hh3cMainPseEntry 5 }
+
+hh3cMainPseLegacy OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(0),
+ disable(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Describes or controls the legacy mode on slot which must be enabled
+ firstly. Legacy mode: standard or nonstandard PD detection mode."
+ ::= { hh3cMainPseEntry 6 }
+
+hh3cMainPsePowerPriority OBJECT-TYPE
+ SYNTAX INTEGER {
+ critical(1),
+ high(2),
+ low(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Describes or controls the priority of the PSE. The priority
+ will be used by the PSE policy to prevent from power overloading.
+ If the priority of PSE is set to critical, the PSE will turn into
+ guaranteed mode. The priority could be used by a control mechanism
+ that prevents power overloading by disconnecting PSEs with lower
+ power priority. PSEs that connect devices critical to the
+ application should be set to higher priority."
+ ::= { hh3cMainPseEntry 7 }
+
+-- Power Profile PSE table
+hh3cPseProfilesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cPseProfilesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of objects representing a set of power profiles.
+ Power profiles can be applied to PoE ports, which have the
+ effect of automatically setting the priority, power limit
+ and PoE enable MIB objects to the values specified in the
+ power profile."
+ ::= { hh3cPowerEthernetExt 7 }
+
+hh3cPseProfilesEntry OBJECT-TYPE
+ SYNTAX Hh3cPseProfilesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A set of objects that display and control the Main power of a PSE."
+ INDEX { hh3cPseProfileIndex }
+ ::= { hh3cPseProfilesTable 1 }
+
+Hh3cPseProfilesEntry ::= SEQUENCE {
+ hh3cPseProfileIndex Integer32,
+ hh3cPseProfileName DisplayString,
+ hh3cPseProfilePowerMode INTEGER,
+ hh3cPseProfilePowerLimit Integer32,
+ hh3cPseProfilePriority INTEGER,
+ hh3cPseProfilePairs INTEGER,
+ hh3cPseProfileApplyNum Integer32,
+ hh3cPseProfileRowStatus RowStatus
+ }
+
+hh3cPseProfileIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..100)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the profile. This uniquely allow the profile to be
+ identified."
+ ::= { hh3cPseProfilesEntry 1 }
+
+hh3cPseProfileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..15))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Assigns the profile a name with which the settings
+ can be assiciated with. For example, 'NBX Phone'."
+ ::= { hh3cPseProfilesEntry 2 }
+
+hh3cPseProfilePowerMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerDisabled (1),
+ powerEnabled (2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The power mode associated with this power profile. There
+ are two possible power modes as follows: powerDisabled,
+ powerEnabled. When a power profile is applied to a PSE port,
+ this value dictates the settings of the ports pethPsePortPowerPriority
+ and pethPsePortAdminEnable objects."
+ ::= { hh3cPseProfilesEntry 3 }
+
+hh3cPseProfilePowerLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The power limit to be applied to the ports hh3cPsePortPowerLimit
+ object when the profile is applied to the PSE port. Expressed in
+ milliWatts."
+ ::= { hh3cPseProfilesEntry 4 }
+
+hh3cPseProfilePriority OBJECT-TYPE
+ SYNTAX INTEGER {
+ critical(1),
+ high(2),
+ low(3)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object controls the priority of the port from the point of
+ view of a power management algorithm. The priority that is set
+ by this variable could be used by a control mechanism that
+ prevents over current situations by disconnecting first ports
+ with lower power priority. Ports that connect devices critical
+ to the operation of the network - like the E911 telephones
+ ports - should be set to higher priority."
+ ::= { hh3cPseProfilesEntry 5 }
+
+hh3cPseProfilePairs OBJECT-TYPE
+ SYNTAX INTEGER {
+ signal(1),
+ spare(2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Describes or controls the pairs in use. If the value of
+ pethPsePortPowerPairsControl is true, this object is writable.
+ A value of signal(1) means that the signal pairs only are in use.
+ A value of spare(2) means that the spare pairs only are in use."
+ REFERENCE
+ "IEEE Std 802.3af Section 30.9.1.1.4 aPSEPowerPairs"
+ ::= { hh3cPseProfilesEntry 6 }
+
+hh3cPseProfileApplyNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of this profile which has been applied.
+ If hh3cPseProfileApplyNum is not zero, user can't
+ change the current line."
+ ::= { hh3cPseProfilesEntry 7 }
+
+hh3cPseProfileRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this classifier.
+ If hh3cPseProfileApplyNum is not zero, user can't
+ delete the current line."
+ ::= { hh3cPseProfilesEntry 8 }
+
+hh3cPseAutoDetectActive OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ notSupported(1),
+ disabled(2),
+ enabled(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The object specifies whether the device auto-detection feature is
+ active. If this object is set to Active, and a known powered device
+ is detected, then the port will automatically switch to Auto-Guaranteed
+ mode. This is a stackwide object (ie. it is not referenced by
+ group index)."
+ ::= { hh3cPowerEthernetExt 3 }
+
+hh3cPsePowerMaxValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The object specifies the max poe power for lanswitch.
+ The value should between the power currently and the max power."
+ ::= { hh3cPowerEthernetExt 5 }
+
+hh3cPsePolicyMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ disabled(1),
+ priority(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The PSE policy only applies to the situation that when a new
+ board (PSE) is inserted, and the power is overload.
+ A value of priority(2) means that the power will stop supplying
+ to the low priority PSE. About PSE priority, please refer to
+ hh3cMainPsePowerPriority. A value of disabled(1) means that the
+ power will stop supplying to the new inserted PSE. The default
+ value of this object is disabled(1)."
+ ::= { hh3cPowerEthernetExt 9 }
+
+hh3cPDPolicyMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ disabled(1),
+ priority(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The PD policy only applies to the situation that when a new
+ PD is inserted, and the power of PSE is overload.
+ A value of priority(2) means that the power will stop supplying
+ to the low priority port PD. About port priority, please refer
+ to pethPsePortPowerPriority. A value of disabled(1) means that
+ the slot stop supplying to the new inserted PD. The default
+ value of this object is disabled(1)."
+ ::= { hh3cPowerEthernetExt 10 }
+
+hh3cpseportNotification OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 6 }
+
+-- Notification Control Objects
+
+hh3cpsePDChangeNotification NOTIFICATION-TYPE
+ OBJECTS { pethPsePortDetectionStatus }
+ STATUS current
+ DESCRIPTION
+ "This notification indicates if PD has been inserted or pulled out."
+ ::= { hh3cpseportNotification 1 }
+
+hh3cPOEDisconnectNotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleDisconnect }
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the POE power module does not disconnect."
+ ::= { hh3cpseportNotification 2 }
+
+hh3cPOEInputErrorNotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleInputError }
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the POE power module input error."
+ ::= { hh3cpseportNotification 3 }
+
+hh3cPOEOutputErrorNotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleOutputError }
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the POE power module output error."
+ ::= { hh3cpseportNotification 4 }
+
+hh3cPOEOverVoltageNotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleOverVoltage }
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the POE power module overruns the
+ voltage limit."
+ ::= { hh3cpseportNotification 5 }
+
+hh3cPOEOverTempNotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleOverTemp }
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the POE power module overruns the
+ temperature limit."
+ ::= { hh3cpseportNotification 6 }
+
+hh3cPOEFanErrorNotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleFanError }
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the POE power module fan error."
+ ::= { hh3cpseportNotification 7 }
+
+hh3cPOEModuleShutdownNotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleShutdown }
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the POE power module is closed."
+ ::= { hh3cpseportNotification 8 }
+
+hh3cPOECurRestrictedNotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleCurRestricted }
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the POE power module current is restricted."
+ ::= { hh3cpseportNotification 9 }
+
+hh3cPOEACSwitchNotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOEACSwitchStateIndex, hh3cPOEACSwitchState }
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the AC input switch alarm of this POE power."
+ ::= { hh3cpseportNotification 10 }
+
+hh3cPOEACInCurANotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOEInCurAState }
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the AC input current A alarm state of
+ this POE power."
+ ::= { hh3cpseportNotification 11 }
+
+hh3cPOEACInCurBNotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOEInCurBState }
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the AC input current B alarm state of
+ this POE power."
+ ::= { hh3cpseportNotification 12 }
+
+hh3cPOEACInCurCNotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOEInCurCState }
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the AC input current C alarm state of
+ this POE power."
+ ::= { hh3cpseportNotification 13 }
+
+hh3cPOEACSwitchVolABNotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOESwitchStateVolExIndex, hh3cPOESwitchStateInVolAB}
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the AC input voltage AB alarm state of
+ this POE power."
+ ::= { hh3cpseportNotification 14 }
+
+hh3cPOEACSwitchVolBCNotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOESwitchStateVolExIndex, hh3cPOESwitchStateInVolBC}
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the AC input voltage BC alarm state of
+ this POE power."
+ ::= { hh3cpseportNotification 15 }
+
+hh3cPOEACSwitchVolCANotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOESwitchStateVolExIndex, hh3cPOESwitchStateInVolCA }
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the AC input voltage CA alarm state of
+ this POE power."
+ ::= { hh3cpseportNotification 16 }
+
+hh3cPOEDCOutVolNotification NOTIFICATION-TYPE
+ OBJECTS { hh3cPOEDCOutStateIndex, hh3cPOEDCOutDCVolAlarm }
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the DC output alarm of this POE power."
+ ::= { hh3cpseportNotification 17 }
+
+hh3cPOEShutdownNotification NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "This notification indicates the whole POE power has been shutdown."
+ ::= { hh3cpseportNotification 18 }
+hh3cPseComformance OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 4 }
+
+hh3cPseCompliances OBJECT IDENTIFIER ::= { hh3cPseComformance 1 }
+
+hh3cPseCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "Description."
+ MODULE -- this module
+ MANDATORY-GROUPS { hh3cPsePortGroup,
+ hh3cMainPseGroup,
+ hh3cPseScalarGroup,
+ hh3cPsePDNotificationGroup
+ }
+ GROUP hh3cPseProfilesGroup
+ DESCRIPTION
+ "This group is mandatory only for executing POE commands as a batch."
+ ::= { hh3cPseCompliances 1 }
+
+hh3cPseGroup OBJECT IDENTIFIER ::= { hh3cPseComformance 2 }
+
+hh3cPsePortGroup OBJECT-GROUP
+ OBJECTS { hh3cPsePortProfileIndex, hh3cPsePortPowerLimit, hh3cPsePortCurrentPower,
+ hh3cPsePortAveragePower, hh3cPsePortPeakPower, hh3cPsePortFaultDescription,
+ hh3cMainPsePriorityMode
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects should be supported at the same time."
+ ::= { hh3cPseGroup 1 }
+
+hh3cMainPseGroup OBJECT-GROUP
+ OBJECTS { hh3cMainPsePowerLimit, hh3cMainPseAveragePower, hh3cMainPsePeakPower,
+ hh3cMainGuaranteedPowerRemaining }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects should be supported at the same time."
+ ::= { hh3cPseGroup 2 }
+
+hh3cPseScalarGroup OBJECT-GROUP
+ OBJECTS { hh3cPseAutoDetectActive, hh3cPsePowerMaxValue, hh3cPsePolicyMode ,
+ hh3cPDPolicyMode }
+ STATUS current
+ DESCRIPTION
+ "A collection of scalar objects supported."
+ ::= { hh3cPseGroup 3 }
+
+hh3cPsePDNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS { hh3cpsePDChangeNotification }
+ STATUS current
+ DESCRIPTION
+ "PD Change Notification."
+ ::= { hh3cPseGroup 4 }
+
+hh3cPseProfilesGroup OBJECT-GROUP
+ OBJECTS { hh3cPseProfileName, hh3cPseProfilePowerMode,
+ hh3cPseProfilePowerLimit, hh3cPseProfilePriority,
+ hh3cPseProfilePairs, hh3cPseProfileApplyNum, hh3cPseProfileRowStatus}
+ STATUS current
+ DESCRIPTION
+ "A collection of objects should be supported at the same time."
+ ::= { hh3cPseGroup 5 }
+
+hh3cPOEPowerThresholdLimitGroup OBJECT-GROUP
+ OBJECTS { hh3cPOEThresholdACMimimum, hh3cPOEThresholdACMaximum,
+ hh3cPOEThresholdDCMinimum, hh3cPOEThresholdDCMaximum }
+ STATUS current
+ DESCRIPTION
+ "Power threshold limits group."
+ ::= { hh3cPseGroup 6 }
+
+hh3cPOEPowerSupInfoGroup OBJECT-GROUP
+ OBJECTS { hh3cPOEPowerType, hh3cPOEPowerModuleNum, hh3cPOESupervisionModuleName,
+ hh3cPOESMMajorVersion, hh3cPOESMMinorVersion, hh3cPOESMFactorName}
+ STATUS current
+ DESCRIPTION
+ "The basic Power information group."
+ ::= { hh3cPseGroup 7 }
+
+hh3cPOEPowerDCOutStateGroup OBJECT-GROUP
+ OBJECTS { hh3cPOEDCOutStateModuleNum }
+ STATUS current
+ DESCRIPTION
+ "The DC out power state group."
+ ::= { hh3cPseGroup 8 }
+
+hh3cPOEPowerDCOutInfoGroup OBJECT-GROUP
+ OBJECTS { hh3cPOEDCOutCurNum }
+ STATUS current
+ DESCRIPTION
+ "The power AC input switch information group"
+ ::= { hh3cPseGroup 9 }
+
+hh3cPOEPowerACSwitchStateModuleGroup OBJECT-GROUP
+ OBJECTS { hh3cPOEACSwitchStateModuleNum}
+ STATUS current
+ DESCRIPTION
+ "PD Change Notification."
+ ::= { hh3cPseGroup 10 }
+
+hh3cPOEPowerInCurStateGroup OBJECT-GROUP
+ OBJECTS { hh3cPOEInCurStateModuleNum, hh3cPOEInCurAState, hh3cPOEInCurBState,
+ hh3cPOEInCurCState}
+ STATUS current
+ DESCRIPTION
+ "PD Change Notification."
+ ::= { hh3cPseGroup 11 }
+
+hh3cPOEPowerAlarmStateGroup OBJECT-GROUP
+ OBJECTS { hh3cPOEAlarmStateModuleNum }
+ STATUS current
+ DESCRIPTION
+ "PD Change Notification."
+ ::= { hh3cPseGroup 12 }
+
+ACAlarmState ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "AC Alarm State."
+ SYNTAX INTEGER{
+ normal (1),
+ underLimit (2),
+ aboveLimit (3),
+ lackPhrase (4),
+ fuseBroken (5),
+ switchOff (6),
+ otherError (7)
+ }
+
+DCAlarmState ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "DC Alarm State."
+ SYNTAX INTEGER{
+ normal (1),
+ underLimit (2),
+ aboveLimit (3),
+ fuseBroken (4),
+ switchOff (5),
+ otherError (6)
+ }
+
+SwitchState ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Switch State."
+SYNTAX INTEGER {
+ on (1),
+ off (2),
+ highVoltInput (3),
+ lowVoltInput (4)
+ }
+
+ModuleAlarmState ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Module Alarm State."
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+
+hh3cPOEPowerObjects OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 8 }
+
+hh3cPOEThresholdLimitObjs OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 1 }
+
+hh3cPOEThresholdACMimimum OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..10))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Input threshold AC minimum.
+ It is a read-write node.
+ The value of this node is 'OCTET STRING',
+ it is used to describe a float value.
+ So this string should fit the following rule:
+ 1. This string should be terminated by '\0';
+ 2. Every characters should be number or radix point;
+ 3. The radix point should occur only once, and it should not
+ be the first or the last character of the string.
+ The value of this node should be smaller than 264.0V and larger than 90.0V.
+ And it should be smaller than the hh3cPOEThresholdACMaximum."
+ ::= { hh3cPOEThresholdLimitObjs 1 }
+
+hh3cPOEThresholdACMaximum OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..10))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Input threshold AC maximum.
+ It is a read-write node.
+ The value of this node is 'OCTET STRING',
+ it is used to describe a float value.
+ So this string should fit the following rule:
+ 1. This string should be terminated by '\0';
+ 2. Every characters should be number or radix point;
+ 3. The radix point should occur only once, and it should not
+ be the first or the last character of the string.
+ It should be smaller than 264.0V and larger than 90.0V.
+ And it should be larger than the hh3cPOEThresholdACMinimum."
+ ::= { hh3cPOEThresholdLimitObjs 2 }
+
+hh3cPOEThresholdDCMinimum OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..10))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Input threshold DC minimum.
+ It is a read-write node.
+ The value of this node is 'OCTET STRING',
+ it is used to describe a float value.
+ So this string should fit the following rule:
+ 1. This string should be terminated by '\0';
+ 2. Every characters should be number or radix point;
+ 3. The radix point should occur only once, and it should not
+ be the first or the last character of the string.
+ It should be smaller than 47.0V and larger than 45.0V."
+ ::= { hh3cPOEThresholdLimitObjs 3 }
+
+hh3cPOEThresholdDCMaximum OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..10))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Input threshold DC maximum.
+ It is a read-write node.
+ The value of this node is 'OCTET STRING',
+ it is used to describe a float value.
+ So this string should fit the following rule:
+ 1. This string should be terminated by '\0';
+ 2. Every characters should be number or radix point;
+ 3. The radix point should occur only once, and it should not
+ be the first or the last character of the string.
+ It should be smaller than 57.0V and larger than 55.0V."
+ ::= { hh3cPOEThresholdLimitObjs 4 }
+
+hh3cPOESupModuleInfoObjs OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 2 }
+
+hh3cPOEPowerType OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..127))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of the power."
+ ::= { hh3cPOESupModuleInfoObjs 1 }
+
+hh3cPOEPowerModuleNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of the power modules."
+ ::= { hh3cPOESupModuleInfoObjs 2 }
+
+hh3cPOESupervisionModuleName OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..127))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object specifies the Supervision Module name on this POE power."
+ ::= { hh3cPOESupModuleInfoObjs 3 }
+
+hh3cPOESMMajorVersion OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object specifies the high byte of the monitor module version."
+ ::= { hh3cPOESupModuleInfoObjs 4 }
+
+hh3cPOESMMinorVersion OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object specifies the low byte of the monitor module version."
+ ::= { hh3cPOESupModuleInfoObjs 5 }
+
+hh3cPOESMFactorName OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..127))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object specifies the name of the manufactor."
+ ::= { hh3cPOESupModuleInfoObjs 6 }
+
+hh3cPOEModuleInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cPOEModuleInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of the module information on this POE power."
+ ::= { hh3cPOESupModuleInfoObjs 7 }
+
+hh3cPOEModuleInfoEntry OBJECT-TYPE
+ SYNTAX Hh3cPOEModuleInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The entry of the module information on this POE power."
+ INDEX { hh3cPOEModuleIndex }
+ ::= { hh3cPOEModuleInfoTable 1 }
+
+Hh3cPOEModuleInfoEntry ::=
+ SEQUENCE {
+ hh3cPOEModuleIndex
+ Integer32,
+ hh3cPOEModuleID
+ Integer32,
+ hh3cPOEModuleInfoPower
+ Integer32,
+ hh3cPOEModuleHardVerInfo
+ OCTET STRING
+ }
+
+hh3cPOEModuleIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The index of the current module on this POE power.
+ It is also the index of hh3cPOEModuleInfoTable.
+ The range of this node is from 1 to hh3cPOEPowerModuleNum."
+ ::= { hh3cPOEModuleInfoEntry 1 }
+
+hh3cPOEModuleID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID of the current module on this POE power."
+ ::= { hh3cPOEModuleInfoEntry 2 }
+
+hh3cPOEModuleInfoPower OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power of the current module on this POE power."
+ ::= { hh3cPOEModuleInfoEntry 3 }
+
+hh3cPOEModuleHardVerInfo OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..127))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The hardware version information of the current module on this POE power."
+ ::= { hh3cPOEModuleInfoEntry 4 }
+
+hh3cPOEDCOutStateObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 3 }
+
+hh3cPOEDCOutStateModuleNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The module number on this POE power.
+ It is the maximum of the hh3cPOEDCOutStateIndex."
+ ::= { hh3cPOEDCOutStateObjects 1 }
+
+hh3cPOEDCOutStateTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cPOEDCOutStateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of DC output power state on this POE power."
+ ::= { hh3cPOEDCOutStateObjects 2 }
+
+hh3cPOEDCOutStateEntry OBJECT-TYPE
+ SYNTAX Hh3cPOEDCOutStateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The entry of the DC output power state on this POE power."
+ INDEX { hh3cPOEDCOutStateIndex }
+ ::= { hh3cPOEDCOutStateTable 1 }
+
+ Hh3cPOEDCOutStateEntry ::=
+ SEQUENCE {
+ hh3cPOEDCOutStateIndex
+ Integer32,
+ hh3cPOEDCOutDCVolAlarm
+ DCAlarmState
+ }
+
+hh3cPOEDCOutStateIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The index of the DC output power state on this POE power.
+ The range of this node is from 1 to hh3cPOEDCOutStateModuleNum."
+ ::= { hh3cPOEDCOutStateEntry 1 }
+
+hh3cPOEDCOutDCVolAlarm OBJECT-TYPE
+ SYNTAX DCAlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The DC output alarm of the DC output power state on this POE power.
+ The value of this node will be the following values:
+ normal (1),
+ underLimit (2),
+ aboveLimit (3),
+ fuseBroken (4),
+ switchOff (5),
+ otherError (6)."
+ ::= { hh3cPOEDCOutStateEntry 2 }
+
+hh3cPOEDCOutInfoObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 4 }
+
+hh3cPOEDCOutCurNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of DC output current on this POE power.
+ It is the maximum of hh3cPOEDCOutInfoIndex."
+ ::= { hh3cPOEDCOutInfoObjects 1 }
+
+hh3cPOEDCOutInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cPOEDCOutInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of the DC output information on this POE power."
+ ::= { hh3cPOEDCOutInfoObjects 2 }
+
+hh3cPOEDCOutInfoEntry OBJECT-TYPE
+ SYNTAX Hh3cPOEDCOutInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The entry of the DC output information on this POE power."
+ INDEX { hh3cPOEDCOutInfoIndex }
+ ::= { hh3cPOEDCOutInfoTable 1 }
+
+Hh3cPOEDCOutInfoEntry ::=
+ SEQUENCE {
+ hh3cPOEDCOutInfoIndex
+ Integer32,
+ hh3cPOEDCOutVol
+ OCTET STRING,
+ hh3cPOEDCOutInfoLoadCur
+ OCTET STRING
+ }
+
+hh3cPOEDCOutInfoIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The index of the DC output information on this POE POWER.
+ The range of this node is from 1 to hh3cPOEDCOutCurNum."
+ ::= { hh3cPOEDCOutInfoEntry 1 }
+
+hh3cPOEDCOutVol OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..10))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The DC output voltage of the current DC output on this POE power."
+ ::= { hh3cPOEDCOutInfoEntry 2 }
+
+hh3cPOEDCOutInfoLoadCur OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..10))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total load current of the current DC output on this POE power."
+ ::= { hh3cPOEDCOutInfoEntry 3 }
+
+hh3cPOEACSwitchStateModuleObjs OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 5 }
+
+hh3cPOEACSwitchStateModuleNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of the AC swtich state module on this POE power.
+ It is the maximum of hh3cPOEACSwitchStateIndex."
+ ::= { hh3cPOEACSwitchStateModuleObjs 1 }
+
+hh3cPOEACSwitchStateTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cPOEACSwitchStateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of the AC switch state on this POE power."
+ ::= { hh3cPOEACSwitchStateModuleObjs 2 }
+
+hh3cPOEACSwitchStateEntry OBJECT-TYPE
+ SYNTAX Hh3cPOEACSwitchStateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The entry of the AC switch state on this POE power."
+ INDEX { hh3cPOEACSwitchStateIndex }
+ ::= { hh3cPOEACSwitchStateTable 1 }
+
+Hh3cPOEACSwitchStateEntry ::=
+ SEQUENCE {
+ hh3cPOEACSwitchStateIndex
+ Integer32,
+ hh3cPOEACSwitchState
+ SwitchState
+ }
+
+hh3cPOEACSwitchStateIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The index of the AC switch state on this POE power.
+ The range of this node is from 1 to hh3cPOEACSwitchStateModuleNum."
+ ::= { hh3cPOEACSwitchStateEntry 1 }
+
+hh3cPOEACSwitchState OBJECT-TYPE
+ SYNTAX SwitchState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The AC switch state on this POE power.
+ The value of this node will be one of the following values:
+ on (1),
+ off (2),
+ highVoltInput (3),
+ lowVoltInput (4)"
+ ::= { hh3cPOEACSwitchStateEntry 2 }
+
+hh3cPOEInCurStateObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 6 }
+
+hh3cPOEInCurStateModuleNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The DC input current state of the module on this POE power.
+ It is the maximum of the hh3cPOESwitchStateVolExIndex."
+ ::= { hh3cPOEInCurStateObjects 1 }
+
+hh3cPOEInCurAState OBJECT-TYPE
+ SYNTAX ACAlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current A state in the DC input on this POE power.
+ normal (1),
+ underLimit (2),
+ aboveLimit (3),
+ lackPhrase (4),
+ fuseBroken (5),
+ switchOff (6),
+ otherError (7)."
+ ::= { hh3cPOEInCurStateObjects 2 }
+
+hh3cPOEInCurBState OBJECT-TYPE
+ SYNTAX ACAlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current B state in the DC input on this POE power.
+ The value of this node will be one of the following values:
+ normal (1),
+ underLimit (2),
+ aboveLimit (3),
+ lackPhrase (4),
+ fuseBroken (5),
+ switchOff (6),
+ otherError (7)."
+ ::= { hh3cPOEInCurStateObjects 3 }
+
+hh3cPOEInCurCState OBJECT-TYPE
+ SYNTAX ACAlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current C state in the DC input on this POE power.
+ The value of this node will be one of the following values:
+ normal (1),
+ underLimit (2),
+ aboveLimit (3),
+ lackPhrase (4),
+ fuseBroken (5),
+ switchOff (6),
+ otherError (7)."
+ ::= { hh3cPOEInCurStateObjects 4 }
+
+hh3cPOESwitchStateVolExTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cPOESwitchStateVolExEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "All alarm status of the VOL status.
+ The value of this node will be one of the following values:
+ normal (1),
+ underLimit (2),
+ aboveLimit (3),
+ lackPhrase (4),
+ fuseBroken (5),
+ switchOff (6),
+ otherError (7)."
+ ::= { hh3cPOEInCurStateObjects 5 }
+
+hh3cPOESwitchStateVolExEntry OBJECT-TYPE
+ SYNTAX Hh3cPOESwitchStateVolExEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The hh3cPOESwitchStateVolExIndex will match the number of the VOL status."
+ INDEX { hh3cPOESwitchStateVolExIndex }
+ ::= { hh3cPOESwitchStateVolExTable 1 }
+
+Hh3cPOESwitchStateVolExEntry ::=
+ SEQUENCE {
+ hh3cPOESwitchStateVolExIndex
+ Integer32,
+ hh3cPOESwitchStateInVolAB
+ ACAlarmState,
+ hh3cPOESwitchStateInVolBC
+ ACAlarmState,
+ hh3cPOESwitchStateInVolCA
+ ACAlarmState
+ }
+
+hh3cPOESwitchStateVolExIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The object species the index of the VOL status.
+ The range of this node is from 1 to hh3cPOEInCurStateModuleNum."
+ ::= { hh3cPOESwitchStateVolExEntry 1 }
+
+hh3cPOESwitchStateInVolAB OBJECT-TYPE
+ SYNTAX ACAlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object specifies the VOL AB alarm in each VOL status.
+ The value of this node will be one of the following values:
+ normal (1),
+ underLimit (2),
+ aboveLimit (3),
+ lackPhrase (4),
+ fuseBroken (5),
+ switchOff (6),
+ otherError (7)."
+ ::= { hh3cPOESwitchStateVolExEntry 2 }
+
+hh3cPOESwitchStateInVolBC OBJECT-TYPE
+ SYNTAX ACAlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object specifies the VOL BC alarm in each VOL status.
+ The value of this node will be one of the following values:
+ normal (1),
+ underLimit (2),
+ aboveLimit (3),
+ lackPhrase (4),
+ fuseBroken (5),
+ switchOff (6),
+ otherError (7)."
+ ::= { hh3cPOESwitchStateVolExEntry 3 }
+
+hh3cPOESwitchStateInVolCA OBJECT-TYPE
+ SYNTAX ACAlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object specifies the VOL CA alarm in each VOL status.
+ The value of this node will be one of the following values:
+ normal (1),
+ underLimit (2),
+ aboveLimit (3),
+ lackPhrase (4),
+ fuseBroken (5),
+ switchOff (6),
+ otherError (7)."
+ ::= { hh3cPOESwitchStateVolExEntry 4 }
+
+hh3cPOEAlarmStateObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 7 }
+
+hh3cPOEAlarmStateModuleNum OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The object specifies the number of the power modules in alarm state."
+ ::= { hh3cPOEAlarmStateObjects 1 }
+
+hh3cPOEAlarmStateInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Hh3cPOEAlarmStateInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "All alarm states in the POE power modules."
+ ::= { hh3cPOEAlarmStateObjects 2 }
+
+hh3cPOEAlarmStateInfoEntry OBJECT-TYPE
+ SYNTAX Hh3cPOEAlarmStateInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The hh3cPOEAlarmModuleInfoIndex will match the number
+ of the power module."
+INDEX { hh3cPOEAlarmModuleInfoIndex }
+ ::= { hh3cPOEAlarmStateInfoTable 1 }
+
+Hh3cPOEAlarmStateInfoEntry ::=
+ SEQUENCE {
+ hh3cPOEAlarmModuleInfoIndex
+ Integer32,
+ hh3cPOEModuleDisconnect
+ ModuleAlarmState,
+ hh3cPOEModuleInputError
+ ModuleAlarmState,
+ hh3cPOEModuleOutputError
+ ModuleAlarmState,
+ hh3cPOEModuleOverVoltage
+ ModuleAlarmState,
+ hh3cPOEModuleOverTemp
+ ModuleAlarmState,
+ hh3cPOEModuleFanError
+ ModuleAlarmState,
+ hh3cPOEModuleShutdown
+ ModuleAlarmState,
+ hh3cPOEModuleCurRestricted
+ ModuleAlarmState
+ }
+
+hh3cPOEAlarmModuleInfoIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The index specifies the index of the Hh3cPOEAlarmStateInfoEntry table.
+ The range of this node is from 1 to hh3cPOEAlarmStateModuleNum."
+ ::= { hh3cPOEAlarmStateInfoEntry 1 }
+
+hh3cPOEModuleDisconnect OBJECT-TYPE
+ SYNTAX ModuleAlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The node specifies the alarm state:
+ The module does not link.
+ The value of this node is one of the following values:
+ normal (1),
+ alarm (2)."
+ ::= { hh3cPOEAlarmStateInfoEntry 2 }
+
+hh3cPOEModuleInputError OBJECT-TYPE
+ SYNTAX ModuleAlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The node specifies the alarm state:
+ Input error.
+ The value of this node is one of the following values:
+ normal (1),
+ alarm (2)."
+ ::= { hh3cPOEAlarmStateInfoEntry 3 }
+
+hh3cPOEModuleOutputError OBJECT-TYPE
+ SYNTAX ModuleAlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The node specifies the alarm state:
+ Output error.
+ The value of this node is one of the following values:
+ normal (1),
+ alarm (2)."
+ ::= { hh3cPOEAlarmStateInfoEntry 4 }
+
+hh3cPOEModuleOverVoltage OBJECT-TYPE
+ SYNTAX ModuleAlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The node specifies the alarm state:
+ The voltage is too high.
+ The value of this node is one of the following values:
+ normal (1),
+ alarm (2)."
+ ::= { hh3cPOEAlarmStateInfoEntry 5 }
+
+hh3cPOEModuleOverTemp OBJECT-TYPE
+ SYNTAX ModuleAlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The node specifies the alarm state:
+ The temperature is too high.
+ The value of this node is one of the following values:
+ normal (1),
+ alarm (2)."
+ ::= { hh3cPOEAlarmStateInfoEntry 6 }
+
+hh3cPOEModuleFanError OBJECT-TYPE
+ SYNTAX ModuleAlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The node specifies the alarm state:
+ The fan error.
+ The value of this node is one of the following values:
+ normal (1),
+ alarm (2)."
+ ::= { hh3cPOEAlarmStateInfoEntry 7 }
+
+hh3cPOEModuleShutdown OBJECT-TYPE
+ SYNTAX ModuleAlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The node specifies the alarm state:
+ The module is shutdown.
+ The value of this node is one of the following values:
+ normal (1),
+ alarm (2)."
+ ::= { hh3cPOEAlarmStateInfoEntry 8 }
+
+hh3cPOEModuleCurRestricted OBJECT-TYPE
+ SYNTAX ModuleAlarmState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The node specifies the alarm state:
+ The module limit the current.
+ The value of this node is one of the following values:
+ normal (1),
+ alarm (2)."
+ ::= { hh3cPOEAlarmStateInfoEntry 9 }
+
+Hh3cPDDisableState ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "PD disabled State."
+ SYNTAX INTEGER{
+ unknown(0),
+ overInrush(1),
+ lessMPSCurrent(2),
+ peakPower(3),
+ overVoltage(4),
+ underVoltage(5),
+ overTemperature(6),
+ shortCircuit(7)
+ }
+
+hh3cPseNotification OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 11 }
+hh3cPseNotificationPrefix OBJECT IDENTIFIER ::= { hh3cPseNotification 0 }
+
+ hh3cPsePDDisableNotification NOTIFICATION-TYPE
+ OBJECTS{ hh3cPsePortGroupIndex, hh3cPsePortIndex, hh3cPsePortDisableInfo }
+ STATUS current
+ DESCRIPTION
+ "The PD has been powered off."
+ ::= { hh3cPseNotificationPrefix 1 }
+
+hh3cPseNotificationObjects OBJECT IDENTIFIER ::= { hh3cPseNotification 1 }
+
+ hh3cPsePortGroupIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "This variable uniquely identifies the group
+ containing the port to which a power Ethernet PSE is
+ connected."
+ ::= { hh3cPseNotificationObjects 1 }
+
+ hh3cPsePortIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "This variable uniquely identifies the power Ethernet PSE
+ port within group pethPsePortGroupIndex to which the
+ power Ethernet PSE entry is connected."
+ ::= { hh3cPseNotificationObjects 2 }
+
+ hh3cPsePortDisableInfo OBJECT-TYPE
+ SYNTAX Hh3cPDDisableState
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "
+ Reason that caused PSE port power failure.
+ The calue of this node is one of the following values:
+ unknown(0),
+ overInrush(1),
+ lessMPSCurrent(2),
+ peakPower(3),
+ overVoltage(4),
+ underVoltage(5),
+ overTemperature(6),
+ shortCircuit(7).
+ "
+ ::= { hh3cPseNotificationObjects 3 }
+
+END
+