diff --git a/MIBS/dasan/SLE-MPLS-TP-OAM-MIB b/MIBS/dasan/SLE-MPLS-TP-OAM-MIB new file mode 100644 index 0000000..3b7eceb --- /dev/null +++ b/MIBS/dasan/SLE-MPLS-TP-OAM-MIB @@ -0,0 +1,1346 @@ +--
+-- sle-mpls-tp-oam-mib.mib
+-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
+-- Friday, February 05, 2016 at 11:01:54
+--
+
+ SLE-MPLS-TP-OAM-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ sleMgmt
+ FROM DASAN-SMI
+ ifGeneralInformationGroup, ifCounterDiscontinuityGroup
+ FROM IF-MIB
+ mplsStdMIB
+ FROM MPLS-TC-STD-MIB
+ SleControlStatusType, SleControlRequestResultType
+ FROM SLE-TC-MIB
+ SnmpAdminString
+ FROM SNMP-FRAMEWORK-MIB
+ zeroDotZero, TimeTicks, Unsigned32, Gauge32, OBJECT-TYPE,
+ MODULE-IDENTITY, OBJECT-IDENTITY
+ FROM SNMPv2-SMI;
+
+
+ sleMplsTpOam MODULE-IDENTITY
+ LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT
+ ORGANIZATION
+ " DASAN Networks"
+ CONTACT-INFO
+ "Gyerok Kwon
+ Dasan Networks
+ Email: grkwon@dasannetworks.com
+
+ Kantharaj B M
+ Dasan Networks
+ Email: kanth@dasannetworks.com
+
+ DongChel Shin (Chris)
+ Dasan Networks
+ Email: dchshin@dasannetworks.com
+
+ Comments about this document should be emailed
+ directly to the Dasan support email ID at
+ support@dasannetworks.com."
+ DESCRIPTION
+ "sleMpls"
+ REVISION "201301080000Z" -- January 08, 2013 at 00:00 GMT
+ DESCRIPTION
+ " "
+ ::= { sleMpls 17 }
+
+
+
+
+--
+-- Node definitions
+--
+
+ sleMpls OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "SLE MPLS."
+ ::= { sleMgmt 16 }
+
+
+ sleMplsTpOamMeg OBJECT IDENTIFIER ::= { sleMplsTpOam 1 }
+
+
+ sleMplsTpOamMegInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleMplsTpOamMegInfoEntry
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This table contains information about the Maintenance
+ Entity Groups (MEG).
+
+ MEG as mentioned in MPLS-TP OAM framework defines a set
+ of one or more maintenance entities (ME).
+ Maintenance Entities define a relationship between any
+ two points of a transport path in an OAM domain to which
+ maintenance and monitoring operations apply."
+ ::= { sleMplsTpOamMeg 1 }
+
+
+ sleMplsTpOamMegInfoEntry OBJECT-TYPE
+ SYNTAX SleMplsTpOamMegInfoEntry
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An entry in this table represents MPLS-TP MEG.
+ An entry can be created by a network administrator
+ or by an SNMP agent as instructed by an MPLS-TP OAM
+ Framework.
+
+ When a new entry is created with
+ sleMplsTpOamMegOperatorType set to ipCompatible (1),
+ then as per [RFC6370] (MEG_ID for LSP is LSP_ID and
+ MEG_ID for PW is PW_Path_ID), MEP_ID can be
+ automatically formed.
+
+ For co-routed bidirectional LSP, MEG_ID is
+ A1-{Global_ID::Node_ID::Tunnel_Num}::Z9-{Global_ID::
+ Node_ID::Tunnel_Num}::LSP_Num.
+
+ For associated bidirectional LSP, MEG_ID is A1-
+ {Global_ID::Node_ID::Tunnel_Num::LSP_Num}:: Z9-
+ {Global_ID::Node_ID::Tunnel_Num::LSP_Num}
+
+ For LSP, MEP_ID is formed using,
+ Global_ID::Node_ID::Tunnel_Num::LSP_Num
+
+ For PW, MEG_ID is formed using AGI::A1-
+ {Global_ID::Node_ID::AC_ID}:: Z9-
+ {Global_ID::Node_ID::AC_ID}.
+
+ For PW, MEP_ID is formed using
+ AGI::Global_ID::Node_ID::AC_ID
+
+ MEP_ID is retrieved from the sleMplsTpOamMegServicePointer
+ object based on the sleMplsTpOamMegServiceType value.
+ ICC MEG_ID for LSP and PW is formed using the objects
+ sleMplsTpOamMegIdIcc and sleMplsTpOamMegIdUmc.
+
+ MEP_ID can be formed using MEG_ID::MEP_Index."
+ REFERENCE
+ "1. RFC 5860, Requirements for OAM in MPLS Transport
+ Networks, May 2010.
+ 2. RFC 6371, Operations, Administration, and Maintenance
+ Framework for MPLS-Based Transport Networks,
+ September 2011.
+ 3. RFC 6370, MPLS Transport Profile (MPLS-TP) Identifiers.
+ 4. MPLS-TP Identifiers Following ITU-T Conventions
+ [TP-ITUIDS]."
+ INDEX { sleMplsTpOamMegInfoIndex }
+ ::= { sleMplsTpOamMegInfoTable 1 }
+
+
+ SleMplsTpOamMegInfoEntry ::=
+ SEQUENCE {
+ sleMplsTpOamMegInfoIndex
+ Unsigned32,
+ sleMplsTpOamMegInfoName
+ OCTET STRING,
+ sleMplsTpOamMegInfoOperatorType
+ INTEGER,
+ sleMplsTpOamMegInfoServiceType
+ INTEGER,
+ sleMplsTpOamMegInfoMegLevel
+ INTEGER,
+ sleMplsTpOamMegInfoOperStatus
+ INTEGER
+ }
+
+ sleMplsTpOamMegInfoIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index for the conceptual row identifying a MEG within
+
+ this MEG table."
+ ::= { sleMplsTpOamMegInfoEntry 1 }
+
+
+ sleMplsTpOamMegInfoName OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..48))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Each Maintenance Entity Group has unique name amongst
+ all those used or available to a service provider or
+ operator. It facilitates easy identification of
+ administrative responsibility for each MEG.
+ IETF : MEG Name Max. 48 characters long
+ ITUT : MEG Name Max 5 characters(Excluding /)."
+ ::= { sleMplsTpOamMegInfoEntry 2 }
+
+
+ sleMplsTpOamMegInfoOperatorType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ietf(1),
+ itut(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the IETF or ITUT. "
+ REFERENCE
+ "1. RFC 6370, MPLS Transport Profile (MPLS-TP)
+ Identifiers.
+ 2. MPLS-TP Identifiers Following ITU-T Conventions
+ [TP-ITUIDS]."
+ ::= { sleMplsTpOamMegInfoEntry 3 }
+
+
+ sleMplsTpOamMegInfoServiceType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ tunnel(1),
+ vc(2),
+ datalink(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the service type for which the MEG is created.
+ If the service type indicates lsp, the service pointer
+ in sleMplsOamMe points to the TE tunnel table entry.
+
+ If the value is pseudowire service type, the service
+ pointer in sleMplsOamMe points to the pseudowire
+ table entry.
+
+ If the value is section service type, the service
+ pointer in sleMplsOamMe points to a section entry."
+ ::= { sleMplsTpOamMegInfoEntry 4 }
+
+
+ sleMplsTpOamMegInfoMegLevel OBJECT-TYPE
+ SYNTAX INTEGER (0..7)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable is used to for level
+ for ITUT. When a row in this table is in active object cannot
+ be changed."
+ ::= { sleMplsTpOamMegInfoEntry 5 }
+
+
+ sleMplsTpOamMegInfoOperStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ up(1),
+ down(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the operational status of the
+ Maintenance Entity Group (MEG). This object is used to
+ send the notification to the SNMP manager about the MEG.
+
+ The value up (1) indicates that the MEG and its monitored
+ path are operationally up. The value down (2) indicates
+ that the MEG is operationally down.
+
+ When the value of mplsOamIdMegOperStatus is up(1), all
+ the bits of mplsOamIdMegSubOperStatus must be cleared.
+ When the value of mplsOamIdMegOperStatus is down(2),
+ at least one bit of mplsOamIdMegSubOperStatus must be
+ set."
+ ::= { sleMplsTpOamMegInfoEntry 6 }
+
+
+ sleMplsTpOamMegControl OBJECT IDENTIFIER ::= { sleMplsTpOamMeg 2 }
+
+
+ sleMplsTpOamMegControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ createsleMplsTpOamMegControlEntry(1),
+ deletesleMplsTpOamMegControlEntry(2),
+ setsleMplsTpOamMegControlServiceType(3),
+ setsleMplsTpOamMegControlLevel(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "the configuration commands, and user can configure
+ functions via setting this entry as proper value."
+ ::= { sleMplsTpOamMegControl 1 }
+
+
+ sleMplsTpOamMegControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "status of user command. User have to check this value as .busy.
+ or .idle. before do setRequest."
+ ::= { sleMplsTpOamMegControl 2 }
+
+
+ sleMplsTpOamMegControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "the wait-time until setRequest end. In case of short-time command,
+ this value is 0"
+ ::= { sleMplsTpOamMegControl 3 }
+
+
+ sleMplsTpOamMegControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the time stamp of the last command. (don.t care)"
+ ::= { sleMplsTpOamMegControl 4 }
+
+
+ sleMplsTpOamMegControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Result of the last command."
+ ::= { sleMplsTpOamMegControl 5 }
+
+
+ sleMplsTpOamMegControlName OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..48))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Each Maintenance Entity Group has unique name amongst
+ all those used or available to a service provider or
+ operator. It facilitates easy identification of
+ administrative responsibility for each MEG."
+ ::= { sleMplsTpOamMegControl 6 }
+
+
+ sleMplsTpOamMegControlOperatorType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ietf(1),
+ itut(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the operator type for MEG. Conceptual rows
+ having 'iccBased' as operator type, should have valid
+ values for the objects sleMplsTpOamMegControlIdIcc and
+ sleMplsTpOamMegControlIdUmc while making the row status active."
+ REFERENCE
+ "1. RFC 6370, MPLS Transport Profile (MPLS-TP)
+ Identifiers.
+ 2. MPLS-TP Identifiers Following ITU-T Conventions
+ [TP-ITUIDS]."
+ ::= { sleMplsTpOamMegControl 7 }
+
+
+ sleMplsTpOamMegControlServiceType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ tunnel(1),
+ vc(2),
+ datalink(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the service type for which the MEG is created.
+ If the service type indicates lsp, the service pointer
+ in sleMplsOamMe points to the TE tunnel table entry.
+
+ If the value is pseudowire service type, the service
+ pointer in sleMplsOamMe points to the pseudowire
+ table entry.
+
+ If the value is section service type, the service
+ pointer in sleMplsOamMe points to a section entry."
+ ::= { sleMplsTpOamMegControl 8 }
+
+
+ sleMplsTpOamMegControlLevel OBJECT-TYPE
+ SYNTAX INTEGER (0..7)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable is used to for level
+ for ITUT. When a row in this table is in active object cannot
+ be changed."
+ ::= { sleMplsTpOamMegControl 9 }
+
+
+ sleMplsTpOamMaintananceEntity OBJECT IDENTIFIER ::= { sleMplsTpOam 2 }
+
+
+ sleMplsTpOamMaintanceEntityInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleMplsTpOamMaintanceEntityInfoEntry
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This table contains MPLS-TP maintenance entity
+ information.
+
+ ME is some portion of a transport path that requires
+ management bounded by two points (called MEPs), and the
+ relationship between those points to which maintenance
+ and monitoring operations apply.
+
+ This table is generic enough to handle MEPs and MIPs
+ information within a MEG."
+ ::= { sleMplsTpOamMaintananceEntity 1 }
+
+
+ sleMplsTpOamMaintanceEntityInfoEntry OBJECT-TYPE
+ SYNTAX SleMplsTpOamMaintanceEntityInfoEntry
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An entry in this table represents MPLS-TP maintenance
+ entity. This entry represents the ME if the source and
+ sink MEPs are defined.
+
+ A ME is a p2p entity. One ME has two such MEPs.
+ A MEG is a group of one or more MEs. One MEG can have
+ two or more MEPs.
+
+ For P2P LSP, one MEG has one ME and this ME is associated
+ two MEPs (source and sink MEPs) within a MEG.
+ Each sleMplsOamMeIndex value denotes the ME within a MEG.
+
+ In case of unidirectional point-to-point transport paths,
+ a single unidirectional Maintenance Entity is defined to
+ monitor it and sleMplsOamMeServicePointer points to
+ unidirectional point-to-point path.
+
+ In case of associated bidirectional point-to-point
+ transport paths, two independent unidirectional
+ Maintenance Entities are defined to independently monitor
+ each direction and each sleMplsOamMeServicePointer MIB
+ object points to unique unidirectional transport path.
+ This has implications for transactions that terminate at
+ or query a MIP, as a return path from MIP to source MEP
+ does not necessarily exist within the MEG.
+
+ In case of co-routed bidirectional point-to-point
+ transport paths, a single bidirectional Maintenance Entity
+
+
+
+ is defined to monitor both directions congruently and
+ sleMplsOamMeServicePointer MIB object points to co-routed
+ bidirectional point-to-point transport path.
+
+ In case of unidirectional point-to-multipoint transport
+ paths, a single unidirectional Maintenance entity for each
+ leaf is defined to monitor the transport path from the
+ root to that leaf and each leaf has different transport
+ path information in sleMplsOamMeServicePointer MIB object."
+ INDEX { sleMplsTpOamMaintanceEntityInfoMeIndex, sleMplsTpOamMaintanceEntityInfoMpIndex }
+ ::= { sleMplsTpOamMaintanceEntityInfoTable 1 }
+
+
+ SleMplsTpOamMaintanceEntityInfoEntry ::=
+ SEQUENCE {
+ sleMplsTpOamMaintanceEntityInfoMeIndex
+ Unsigned32,
+ sleMplsTpOamMaintanceEntityInfoMpIndex
+ Unsigned32,
+ sleMplsOamMaintenanceEntityInfoMeName
+ SnmpAdminString,
+ sleMplsTpOamMaintanceEntityInfoMpType
+ INTEGER,
+ sleMplsOamMaintenanceEntityInfoServiceTunnelName
+ OCTET STRING,
+ sleMplsOamMaintenanceEntityInfoServiceVcId
+ Unsigned32,
+ sleMplsOamMaintenanceEntityInfoServiceDatalink
+ OCTET STRING,
+ sleMplsTpOamMaintanceEntityInfoCcInterval
+ Unsigned32,
+ sleMplsTpOamMaintanceEntityInfoRemoteMpId
+ Unsigned32,
+ sleMplsTpOamMaintanceEntityInfoRemoteCc
+ OCTET STRING,
+ sleMplsTpOamMaintanceEntityInfoRemoteIcc
+ OCTET STRING,
+ sleMplsTpOamMaintanceEntityInfoRemoteMeg
+ OCTET STRING,
+ sleMplsTpOamMaintanceEntityInfoRemoteMpdirection
+ INTEGER
+ }
+
+ sleMplsTpOamMaintanceEntityInfoMeIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Uniquely identifies a maintenance entity index within
+ a MEG."
+ ::= { sleMplsTpOamMaintanceEntityInfoEntry 1 }
+
+
+ sleMplsTpOamMaintanceEntityInfoMpIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..8191)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Indicates the maintenance point index, used to create
+ multiple MEPs in a node of single ME. The value of this
+ object can be MEP index or MIP index. Managers should
+ obtain new values for row creation in this table by reading
+ mplsOamIdMeMpIndexNext."
+ ::= { sleMplsTpOamMaintanceEntityInfoEntry 2 }
+
+
+ sleMplsOamMaintenanceEntityInfoMeName OBJECT-TYPE
+ SYNTAX SnmpAdminString (SIZE (1..48))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object denotes the ME name, each
+ Maintenance Entity has unique name within MEG."
+ ::= { sleMplsTpOamMaintanceEntityInfoEntry 3 }
+
+
+ sleMplsTpOamMaintanceEntityInfoMpType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ mep(1),
+ mip(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the maintenance point type within the MEG.
+ The object should have the value mep (1), only in the
+ Ingress or Egress nodes of the transport path.
+ The object can have the value mip (2),
+ in the intermediate nodes and possibly in the end nodes
+ of the transport path."
+ ::= { sleMplsTpOamMaintanceEntityInfoEntry 4 }
+
+
+ sleMplsOamMaintenanceEntityInfoServiceTunnelName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable represents a pointer to the MPLS-TP
+ transport path. This value may point at an entry in the
+ sleMplsTunnelEntry ifsleMplsOamMaintenanceEntitygServiceType is configured
+ as lsp (1) or at an entry in the pwEntry if
+ sleMplsOamMaintenanceEntitygServiceType is configured as pseudowire (2).
+
+ Note: This service pointer object, is placed in ME table
+ instead of MEG table, since it will be useful in case of
+ point-to-multipoint, where each ME will point to different
+ branches of a P2MP tree."
+ ::= { sleMplsTpOamMaintanceEntityInfoEntry 5 }
+
+
+ sleMplsOamMaintenanceEntityInfoServiceVcId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable represents a pointer to the MPLS-TP
+ transport path. This value may point at an entry in the
+ sleMplsTunnelEntry ifsleMplsOamMaintenanceEntitygServiceType is configured
+ as lsp (1) or at an entry in the pwEntry if
+ sleMplsOamMaintenanceEntitygServiceType is configured as pseudowire (2).
+
+ Note: This service pointer object, is placed in ME table
+ instead of MEG table, since it will be useful in case of
+ point-to-multipoint, where each ME will point to different
+ branches of a P2MP tree."
+ ::= { sleMplsTpOamMaintanceEntityInfoEntry 6 }
+
+
+ sleMplsOamMaintenanceEntityInfoServiceDatalink OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable represents a pointer to the MPLS-TP
+ transport path. This value may point at an entry in the
+ sleMplsTunnelEntry ifsleMplsOamMaintenanceEntitygServiceType is configured
+ as lsp (1) or at an entry in the pwEntry if
+ sleMplsOamMaintenanceEntitygServiceType is configured as pseudowire (2).
+
+ Note: This service pointer object, is placed in ME table
+ instead of MEG table, since it will be useful in case of
+ point-to-multipoint, where each ME will point to different
+ branches of a P2MP tree."
+ ::= { sleMplsTpOamMaintanceEntityInfoEntry 7 }
+
+
+ sleMplsTpOamMaintanceEntityInfoCcInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (1..7)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable is used to keep the continuty check interval
+ for ITUT. When a row in this table is in active object cannot
+ be changed."
+ ::= { sleMplsTpOamMaintanceEntityInfoEntry 8 }
+
+
+ sleMplsTpOamMaintanceEntityInfoRemoteMpId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..8191)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable is used for setting the remote mep id "
+ ::= { sleMplsTpOamMaintanceEntityInfoEntry 9 }
+
+
+ sleMplsTpOamMaintanceEntityInfoRemoteCc OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..2))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Global uniqueness is assured by concatenating the ICC
+ with a Country Code (CC). The Country Code (alpha-2)
+ is a string of two alphabetic characters represented
+ with upper case letters (i.e., A-Z).
+
+ This object MUST contain a non-null ICC value if
+ the MplsOamIdMegOperatorType value is iccBased(2),
+ otherwise a null ICC value with octet size 0
+ should be assigned."
+ REFERENCE
+ "RFC6923, MPLS Transport Profile (MPLS-TP) Identifiers
+ Following ITU-T Conventions. Section 3."
+ DEFVAL { "" }
+ ::= { sleMplsTpOamMaintanceEntityInfoEntry 10 }
+
+
+ sleMplsTpOamMaintanceEntityInfoRemoteIcc OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..6))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Unique code assigned to Network Operator or Service
+ Provider maintained by ITU-T. The ITU Carrier Code
+ used to form MEGID.
+
+ This object MUST contain a non-null ICC value if
+ the MplsOamIdMegOperatorType value is iccBased(2),
+ otherwise a null ICC value with octet size 0
+ should be assigned."
+ REFERENCE
+ "RFC6923, MPLS Transport Profile (MPLS-TP) Identifiers
+ Following ITU-T Conventions. Section 3.1."
+ DEFVAL { "" }
+ ::= { sleMplsTpOamMaintanceEntityInfoEntry 11 }
+
+
+ sleMplsTpOamMaintanceEntityInfoRemoteMeg OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..6))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Unique code assigned by Network Operator or Service
+ Provider and is appended to mplsOamIdMegIdIcc to form
+ the MEGID.
+ This object MUST contain a non-null ICC value if
+ the MplsOamIdMegOperatorType value is iccBased(2),
+ otherwise a null ICC value with octet size 0
+ should be assigned."
+ REFERENCE
+ "RFC6923, MPLS Transport Profile (MPLS-TP) Identifiers
+ Following ITU-T Conventions. Section 7.1."
+ DEFVAL { "" }
+ ::= { sleMplsTpOamMaintanceEntityInfoEntry 12 }
+
+
+ sleMplsTpOamMaintanceEntityInfoRemoteMpdirection OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ forward(1),
+ reverse(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the maintenance point type within the MEG.
+ This object is used to display the forward and reverse remote mep of
+ Transist router ."
+ ::= { sleMplsTpOamMaintanceEntityInfoEntry 13 }
+
+
+ sleMplsTpOamMaintanceEntityControl OBJECT IDENTIFIER ::= { sleMplsTpOamMaintananceEntity 2 }
+
+
+ sleMplsTpOamMaintanceEntityRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ createsleMplsTpOamMaintanceEntityControlEntry(1),
+ deletesleMplsTpOamMaintanceEntityControlEntry(2),
+ setsleMplsTpOamMaintanceEntityControlServiceValue(3),
+ setSleMplsTpOamMepControlCCInterval(4),
+ unsetSleMplsTpOamMepControlCCInterval(5),
+ setsleMplsTpOamMaintanceEntityControlRmepId(6),
+ unsetsleMplsTpOamMaintanceEntityControlRmepId(7)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "the configuration commands, and user can configure functions
+ via setting this entry as proper value."
+ ::= { sleMplsTpOamMaintanceEntityControl 1 }
+
+
+ sleMplsTpOamMaintanceEntityControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "status of user command. User have to check this value as
+ .busy. or .idle. before do setRequest."
+ ::= { sleMplsTpOamMaintanceEntityControl 2 }
+
+
+ sleMplsTpOamMaintanceEntityControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "the wait-time until setRequest end. In case of short-time
+ command, this value is 0"
+ ::= { sleMplsTpOamMaintanceEntityControl 3 }
+
+
+ sleMplsTpOamMaintanceEntityControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the time stamp of the last command. (don.t care)"
+ ::= { sleMplsTpOamMaintanceEntityControl 4 }
+
+
+ sleMplsTpOamMaintanceEntityControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Result of the last command."
+ ::= { sleMplsTpOamMaintanceEntityControl 5 }
+
+
+ sleMplsTpOamMaintanceEntityControlMegName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Uniquely identifies a maintenance entity index within
+ a MEG."
+ ::= { sleMplsTpOamMaintanceEntityControl 6 }
+
+
+ sleMplsTpOamMaintanceEntityControlMeName OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..48))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object denotes the ME name, each
+ Maintenance Entity has unique name within MEG."
+ ::= { sleMplsTpOamMaintanceEntityControl 7 }
+
+
+ sleMplsTpOamMaintanceEntityControlMepId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..8191)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Uniquely identifies a maintenance entity index within
+ a MEP ."
+ ::= { sleMplsTpOamMaintanceEntityControl 8 }
+
+
+ sleMplsTpOamMaintanceEntityControlMpType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ mep(1),
+ mip(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the maintenance point type within the MEG.
+
+ The object should have the value mep (1), only in the
+ Ingress or Egress nodes of the transport path.
+
+ The object can have the value mip (2),
+ in the intermediate nodes and possibly in the end nodes
+ of the transport path."
+ ::= { sleMplsTpOamMaintanceEntityControl 9 }
+
+
+ sleMplsTpOamMaintanceEntityControlServiceValue OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable represents a pointer to the MPLS-TP
+ transport path. This value may point at an entry in the
+ sleMplsTunnelEntry if sleMplsOamMeControlgServiceType is configured
+ as lsp (1) or at an entry in the pwEntry if
+ sleMplsOamMeControlgServiceType is configured as pseudowire (2).
+
+ Note: This service pointer object, is placed in ME table
+ instead of MEG table, since it will be useful in case of
+ point-to-multipoint, where each ME will point to different
+ branches of a P2MP tree."
+ ::= { sleMplsTpOamMaintanceEntityControl 10 }
+
+
+ sleMplsTpOamMaintanceEntityControlCcInterval OBJECT-TYPE
+ SYNTAX Unsigned32 (1..7)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable is used to keep the continuty check interval
+ for ITUT. When a row in this table is in active object cannot
+ be changed."
+ ::= { sleMplsTpOamMaintanceEntityControl 11 }
+
+
+ sleMplsTpOamMaintanceEntityControlRemoteMpId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..8191)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable is used for setting the remote mep id "
+ ::= { sleMplsTpOamMaintanceEntityControl 12 }
+
+
+ sleMplsTpOamMaintanceEntityControlRemoteCc OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..2))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Global uniqueness is assured by concatenating the ICC
+ with a Country Code (CC). The Country Code (alpha-2)
+ is a string of two alphabetic characters represented
+ with upper case letters (i.e., A-Z).
+
+ This object MUST contain a non-null ICC value if
+ the MplsOamIdMegOperatorType value is iccBased(2),
+ otherwise a null ICC value with octet size 0
+ should be assigned."
+ REFERENCE
+ "RFC6923, MPLS Transport Profile (MPLS-TP) Identifiers
+ Following ITU-T Conventions. Section 3."
+ DEFVAL { "" }
+ ::= { sleMplsTpOamMaintanceEntityControl 13 }
+
+
+ sleMplsTpOamMaintanceEntityControlRemoteIcc OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..6))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Unique code assigned to Network Operator or Service
+ Provider maintained by ITU-T. The ITU Carrier Code
+ used to form MEGID.
+
+ This object MUST contain a non-null ICC value if
+ the MplsOamIdMegOperatorType value is iccBased(2),
+ otherwise a null ICC value with octet size 0
+ should be assigned."
+ REFERENCE
+ "RFC6923, MPLS Transport Profile (MPLS-TP) Identifiers
+ Following ITU-T Conventions. Section 3.1."
+ DEFVAL { "" }
+ ::= { sleMplsTpOamMaintanceEntityControl 14 }
+
+
+ sleMplsTpOamMaintanceEntityControlRemoteMeg OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..7))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Unique code assigned by Network Operator or Service
+ Provider and is appended to mplsOamIdMegIdIcc to form
+ the MEGID.
+ This object MUST contain a non-null ICC value if
+ the MplsOamIdMegOperatorType value is iccBased(2),
+ otherwise a null ICC value with octet size 0
+ should be assigned."
+ REFERENCE
+ "RFC6923, MPLS Transport Profile (MPLS-TP) Identifiers
+ Following ITU-T Conventions. Section 7.1."
+ DEFVAL { "" }
+ ::= { sleMplsTpOamMaintanceEntityControl 15 }
+
+
+ sleMplsTpOamMaintanceEntityControlRemoteMpDirection OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ fwd(1),
+ rev(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the direction of the MEP. This object
+ should be configured if sleMplsOamMeControlMpType is
+ configured as mep (1)."
+ ::= { sleMplsTpOamMaintanceEntityControl 16 }
+
+
+ sleMplsTpOamFm OBJECT IDENTIFIER ::= { sleMplsTpOam 3 }
+
+
+ sleMplsTpOamFmInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleMplsTpOamFmInfoEntry
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION " "
+ ::= { sleMplsTpOamFm 1 }
+
+
+ sleMplsTpOamFmInfoEntry OBJECT-TYPE
+ SYNTAX SleMplsTpOamFmInfoEntry
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An entry in this table represents MPLS-TP maintenance
+ entity."
+ INDEX { sleMplsTpOamFmInfoMegIndex, sleMplsTpOamFmInfoMeIndex, sleMplsTpOamFmInfoMpIndex }
+ ::= { sleMplsTpOamFmInfoTable 1 }
+
+
+ SleMplsTpOamFmInfoEntry ::=
+ SEQUENCE {
+ sleMplsTpOamFmInfoMeIndex
+ Unsigned32,
+ sleMplsTpOamFmInfoMpIndex
+ Unsigned32,
+ sleMplsTpOamFmInfoFaultManagement
+ INTEGER,
+ sleMplsTpOamFmInfoRefreshTime
+ Unsigned32,
+ sleMplsTpOamFmInfoLockInstruct
+ INTEGER,
+ sleMplsTpOamFmInfoLockInstructRefreshTime
+ Unsigned32,
+ sleMplsTpOamFmInfoAlarmIndication
+ INTEGER,
+ sleMplsTpOamFmInfoAlarmIndicationInterval
+ INTEGER,
+ sleMplsTpOamFmInfoAlarmIndicationLevel
+ INTEGER,
+ sleMplsTpOamFmInfoLock
+ INTEGER,
+ sleMplsTpOamFmInfoLockInterval
+ INTEGER,
+ sleMplsTpOamFmInfoLockLevel
+ INTEGER,
+ sleMplsTpOamFmInfoLoopBack
+ INTEGER,
+ sleMplsTpOamFmInfoLoopBackStatus
+ INTEGER,
+ sleMplsTpOamFmInfoLockInstructStatus
+ INTEGER,
+ sleMplsTpOamFmInfoFaultManagementStatus
+ INTEGER,
+ sleMplsTpOamFmInfoCcCvStatus
+ INTEGER,
+ sleMplsTpOamFmInfoStatus
+ INTEGER
+ }
+
+ sleMplsTpOamFmInfoMeIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Uniquely identifies a maintenance entity index within
+ a MEG."
+ ::= { sleMplsTpOamFmInfoEntry 1 }
+
+
+ sleMplsTpOamFmInfoMpIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..8191)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Indicates the maintenance point index, used to create
+ multiple MEPs in a node of single ME. The value of this
+ object can be MEP index or MIP index. Managers should
+ obtain new values for row creation in this table by reading
+ mplsOamIdMeMpIndexNext."
+ ::= { sleMplsTpOamFmInfoEntry 2 }
+
+
+ sleMplsTpOamFmInfoFaultManagement OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fault Managment for IETF shows enable or disable"
+ DEFVAL { disable }
+ ::= { sleMplsTpOamFmInfoEntry 3 }
+
+
+ sleMplsTpOamFmInfoRefreshTime OBJECT-TYPE
+ SYNTAX Unsigned32 (1..20)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This Object is used in IETF-based Fault Management RefreshTimer."
+ DEFVAL { 0 }
+ ::= { sleMplsTpOamFmInfoEntry 4 }
+
+
+ sleMplsTpOamFmInfoLockInstruct OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Lock instruct for IETF shows enable or disable"
+ DEFVAL { disable }
+ ::= { sleMplsTpOamFmInfoEntry 5 }
+
+
+ sleMplsTpOamFmInfoLockInstructRefreshTime OBJECT-TYPE
+ SYNTAX Unsigned32 (1..20)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This Object is used in IETF-based lock RefreshTimer."
+ DEFVAL { 0 }
+ ::= { sleMplsTpOamFmInfoEntry 6 }
+
+
+ sleMplsTpOamFmInfoAlarmIndication OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Alarm indication for ITUT shows enable or disable."
+ DEFVAL { disable }
+ ::= { sleMplsTpOamFmInfoEntry 7 }
+
+
+ sleMplsTpOamFmInfoAlarmIndicationInterval OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ oneSecond(1),
+ sixtySeconds(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is object to display the itut alarm indication interval value. "
+ ::= { sleMplsTpOamFmInfoEntry 8 }
+
+
+ sleMplsTpOamFmInfoAlarmIndicationLevel OBJECT-TYPE
+ SYNTAX INTEGER (0..7)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object to display the Itut alarm indication Level value. "
+ ::= { sleMplsTpOamFmInfoEntry 9 }
+
+
+ sleMplsTpOamFmInfoLock OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This Object is used in ITUT-based lock. This object will enable/disable the lock"
+ DEFVAL { disable }
+ ::= { sleMplsTpOamFmInfoEntry 10 }
+
+
+ sleMplsTpOamFmInfoLockInterval OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ oneSecond(1),
+ sixtySeconds(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to display the ITUT based Lock Interval. "
+ ::= { sleMplsTpOamFmInfoEntry 11 }
+
+
+ sleMplsTpOamFmInfoLockLevel OBJECT-TYPE
+ SYNTAX INTEGER (0..7)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to Display the ITUT based Lock Level. "
+ ::= { sleMplsTpOamFmInfoEntry 12 }
+
+
+ sleMplsTpOamFmInfoLoopBack OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This Object is used in IETF-based loop back. This will show enable/disable loop back ."
+ DEFVAL { 2 }
+ ::= { sleMplsTpOamFmInfoEntry 13 }
+
+
+ sleMplsTpOamFmInfoLoopBackStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ up(1),
+ down(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object to display the Status of IETF Based LoopBackStatus."
+ DEFVAL { 2 }
+ ::= { sleMplsTpOamFmInfoEntry 14 }
+
+
+ sleMplsTpOamFmInfoLockInstructStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ up(1),
+ down(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object to display the Status of IETF Based LockInstruct."
+ DEFVAL { 2 }
+ ::= { sleMplsTpOamFmInfoEntry 15 }
+
+
+ sleMplsTpOamFmInfoFaultManagementStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ up(1),
+ down(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object to display the Status of IETF Based FaultManagement."
+ DEFVAL { 2 }
+ ::= { sleMplsTpOamFmInfoEntry 16 }
+
+
+ sleMplsTpOamFmInfoCcCvStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ enabled(1),
+ disabled(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object to display the Status of IETF Based CC-CV."
+ DEFVAL { 2 }
+ ::= { sleMplsTpOamFmInfoEntry 17 }
+
+
+ sleMplsTpOamFmInfoStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ pathNotAssociated(1),
+ pathAssociateWithAnotherMe(2),
+ pathDown(3),
+ receivedAisFmMessage(4),
+ receviedLkrFmMessage(5),
+ bfdDetecLoc(6),
+ serverLayerDown(7),
+ invalidMe(8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to display the IETF Status
+ 1- path not Associated.
+ 2- path associated with another me.
+ 3- path down
+ 4- received AIS Message.
+ 5- received LKR FM Message.
+ 6- Bfd Detected Loc.
+ 7- Server Layer Down.
+ 8- Invalid Me."
+ ::= { sleMplsTpOamFmInfoEntry 18 }
+
+
+ sleMplsTpOamFmControlTable OBJECT IDENTIFIER ::= { sleMplsTpOamFm 2 }
+
+
+ sleMplsTpOamFmControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ setSleMplsTpOamFmControlInit(1),
+ unsetSleMplsTpOamFmControlInit(2),
+ setSleMplsTpOamItutAis(3),
+ unsetSleMplsTpOamItutAis(4),
+ setSleMplsTpOamItutLockInterval(5),
+ unsetSleMplsTpOamItutLockInterval(6)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "the configuration commands, and user can configure functions via setting this entry as proper value."
+ ::= { sleMplsTpOamFmControlTable 1 }
+
+
+ sleMplsTpOamFmControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "status of user command. User have to check this value as .busy. or .idle. before do setRequest."
+ ::= { sleMplsTpOamFmControlTable 2 }
+
+
+ sleMplsTpOamFmControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "the wait-time until setRequest end. In case of short-time command, this value is 0"
+ ::= { sleMplsTpOamFmControlTable 3 }
+
+
+ sleMplsTpOamFmControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the time stamp of the last command. (don.t care)"
+ ::= { sleMplsTpOamFmControlTable 4 }
+
+
+ sleMplsTpOamFmControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Result of the last command."
+ ::= { sleMplsTpOamFmControlTable 5 }
+
+
+ sleMplsTpOamFmControlMegName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Uniquely identifies a maintenance entity index within
+ a MEG."
+ ::= { sleMplsTpOamFmControlTable 6 }
+
+
+ sleMplsTpOamFmControlMeName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Uniquely identifies a maintenance entity index within
+ a ME."
+ ::= { sleMplsTpOamFmControlTable 7 }
+
+
+ sleMplsTpOamFmControlMepId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..8191)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Uniquely identifies a maintenance entity index within
+ a MEP."
+ ::= { sleMplsTpOamFmControlTable 8 }
+
+
+ sleMplsTpOamFmInit OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ faultMeasurment(1),
+ lockInstruct(2),
+ loopBack(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable is used for setting the fault Measurments for IETF/ITUT based upon gloable configuration
+ 1) Fault measurment is for IETF
+ 2) Lock-Instruct is for IETF
+ 3) LoopBack to configure for IETF "
+ ::= { sleMplsTpOamFmControlTable 9 }
+
+
+ sleMplsTpOamFmControlRefreshTime OBJECT-TYPE
+ SYNTAX Unsigned32 (1..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This varible is used to set the Refresh Time for IETF of 2 objects ie., Fault managment and Lock Instruct
+ 1) Fault managment range (1-20)
+ 2) Lock-Instruct range (1-255)"
+ ::= { sleMplsTpOamFmControlTable 10 }
+
+
+ sleMplsTpOamFmControlInterval OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ oneOne(1),
+ sixtyOne(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable is used to set the interval for 2 alarm-inidaction and lock objects of ITUT"
+ ::= { sleMplsTpOamFmControlTable 11 }
+
+
+ sleMplsTpOamFmControlLevel OBJECT-TYPE
+ SYNTAX INTEGER (0..7)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This varible is used to set the level for Alarm indication and lock objects of ITUT"
+ ::= { sleMplsTpOamFmControlTable 12 }
+
+
+
+ END
+
+--