diff options
Diffstat (limited to 'MIBS/dasan/SLE-MPLS-TP-TUNNEL-MIB')
| -rw-r--r-- | MIBS/dasan/SLE-MPLS-TP-TUNNEL-MIB | 909 |
1 files changed, 909 insertions, 0 deletions
diff --git a/MIBS/dasan/SLE-MPLS-TP-TUNNEL-MIB b/MIBS/dasan/SLE-MPLS-TP-TUNNEL-MIB new file mode 100644 index 0000000..fb36f90 --- /dev/null +++ b/MIBS/dasan/SLE-MPLS-TP-TUNNEL-MIB @@ -0,0 +1,909 @@ +--
+-- sle-mpls-tp-tunnel-mib.mib
+-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
+-- Friday, January 15, 2016 at 13:52:12
+--
+
+ SLE-MPLS-TP-TUNNEL-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ sleMgmt
+ FROM DASAN-SMI
+ ifGeneralInformationGroup, ifCounterDiscontinuityGroup, InterfaceIndexOrZero
+ FROM IF-MIB
+ MplsCcId, MplsIccId
+ FROM MPLS-TC-EXT-STD-MIB
+ mplsStdMIB, MplsLabel
+ FROM MPLS-TC-STD-MIB
+ SleControlStatusType, SleControlRequestResultType
+ FROM SLE-TC-MIB
+ zeroDotZero, TimeTicks, IpAddress, Unsigned32, Gauge32,
+ OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY
+ FROM SNMPv2-SMI
+ MacAddress
+ FROM SNMPv2-TC;
+
+
+ sleMplsTpTunnel MODULE-IDENTITY
+ LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT
+ ORGANIZATION
+ "Multiprotocol Label Switching (MPLS) Working Group"
+ CONTACT-INFO
+ "Gyerok Kwon
+ Dasan Networks
+ Email: grkwon@dasannetworks.com
+
+ Kantharaj B M
+ Dasan Networks
+ Email: kanth@dasannetworks.com
+
+ DongChel Shin (Chris)
+ Dasan Networks
+ Email: dchshin@dasannetworks.com
+
+ Comments about this document should be emailed
+ directly to the Dasan support email ID at
+ support@dasannetworks.com."
+ DESCRIPTION
+ "Copyright (C) The Internet Society (2004). The
+ initial version of this MIB module was published
+ in RFC 3812. For full legal notices see the RFC
+ itself or see: http://www.ietf.org/copyrights/ianamib.html
+
+ This MIB module contains managed object definitions
+ for MPLS Traffic Engineering (TE) as defined in:
+ 1. Extensions to RSVP for LSP Tunnels, Awduche et
+ al, RFC 3209, December 2001
+ 2. Constraint-Based LSP Setup using LDP, Jamoussi
+
+ (Editor), RFC 3212, January 2002
+ 3. Requirements for Traffic Engineering Over MPLS,
+ Awduche, D., Malcolm, J., Agogbua, J., O'Dell, M.,
+ and J. McManus, [RFC2702], September 1999"
+ REVISION "200406030000Z" -- June 03, 2004 at 00:00 GMT
+ DESCRIPTION
+ "Initial version issued as part of RFC 3812."
+ ::= { sleMpls 14 }
+
+
+
+
+--
+-- Node definitions
+--
+
+ sleMpls OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION
+ "SLE MPLS."
+ ::= { sleMgmt 16 }
+
+
+ sleMplsTpTunnelCfg OBJECT IDENTIFIER ::= { sleMplsTpTunnel 1 }
+
+
+ sleMplsTpTunnelCfgInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SleMplsTpTunnelCfgInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The mplsTunnelTable allows new MPLS tunnels to be
+ created between an LSR and a remote endpoint, and
+ existing tunnels to be reconfigured or removed.
+ Note that only point-to-point tunnel segments are
+ supported, although multipoint-to-point and point-
+ to-multipoint connections are supported by an LSR
+ acting as a cross-connect. Each MPLS tunnel can
+ thus have one out-segment originating at this LSR
+ and/or one in-segment terminating at this LSR."
+ ::= { sleMplsTpTunnelCfg 1 }
+
+
+ sleMplsTpTunnelCfgInfoEntry OBJECT-TYPE
+ SYNTAX SleMplsTpTunnelCfgInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in this table represents an MPLS tunnel.
+ An entry can be created by a network administrator
+ or by an SNMP agent as instructed by an MPLS
+ signalling protocol. Whenever a new entry is
+ created with mplsTunnelIsIf set to true(1), then a
+ corresponding entry is created in ifTable as well
+ (see RFC 2863). The ifType of this entry is
+ mplsTunnel(150).
+
+ A tunnel entry needs to be uniquely identified across
+ a MPLS network. Indices mplsTunnelIndex and
+ mplsTunnelInstance uniquely identify a tunnel on
+ the LSR originating the tunnel. To uniquely
+ identify a tunnel across an MPLS network requires
+
+ index mplsTunnelIngressLSRId. The last index
+ mplsTunnelEgressLSRId is useful in identifying all
+ instances of a tunnel that terminate on the same
+ egress LSR."
+ REFERENCE
+ "1. RFC 2863 - The Interfaces Group MIB, McCloghrie,
+ K., and F. Kastenholtz, June 2000 "
+ INDEX { sleMplsTpTunnelCfgInfoIndex }
+ ::= { sleMplsTpTunnelCfgInfoTable 1 }
+
+
+ SleMplsTpTunnelCfgInfoEntry ::=
+ SEQUENCE {
+ sleMplsTpTunnelCfgInfoIndex
+ Unsigned32,
+ sleMplsTpTunnelCfgInfoName
+ OCTET STRING,
+ sleMplsTpTunnelCfgInfoId
+ Unsigned32,
+ sleMplsTpTunnelCfgInfoSrcIdType
+ INTEGER,
+ sleMplsTpTunnelCfgInfoSrcGId
+ Unsigned32,
+ sleMplsTpTunnelCfgInfoSrcCc
+ MplsCcId,
+ sleMplsTpTunnelCfgInfoSrcIcc
+ MplsIccId,
+ sleMplsTpTunnelCfgInfoSrcNodeId
+ IpAddress,
+ sleMplsTpTunnelCfgInfoDestIdType
+ INTEGER,
+ sleMplsTpTunnelCfgInfoDestGId
+ Unsigned32,
+ sleMplsTpTunnelCfgInfoDestCc
+ MplsCcId,
+ sleMplsTpTunnelCfgInfoDestIcc
+ MplsIccId,
+ sleMplsTpTunnelCfgInfoDestNodeId
+ IpAddress,
+ sleMplsTpTunnelCfgInfoMode
+ INTEGER,
+ sleMplsTpTunnelCfgInfoFwdInLabel
+ MplsLabel,
+ sleMplsTpTunnelCfgInfoFwdInIfIndex
+ InterfaceIndexOrZero,
+ sleMplsTpTunnelCfgInfoFwdOperation
+ INTEGER,
+ sleMplsTpTunnelCfgInfoFwdOutLabel
+ MplsLabel,
+ sleMplsTpTunnelCfgInfoFwdOutIfIndex
+ InterfaceIndexOrZero,
+ sleMplsTpTunnelCfgInfoFwdOutMac
+ MacAddress,
+ sleMplsTpTunnelCfgInfoRevInLabel
+ MplsLabel,
+ sleMplsTpTunnelCfgInfoRevInIfIndex
+ InterfaceIndexOrZero,
+ sleMplsTpTunnelCfgInfoRevOperation
+ INTEGER,
+ sleMplsTpTunnelCfgInfoRevOutLabel
+ MplsLabel,
+ sleMplsTpTunnelCfgInfoRevOutIfIndex
+ InterfaceIndexOrZero,
+ sleMplsTpTunnelCfgInfoRevOutMac
+ MacAddress,
+ sleMplsTpTunnelCfgInfoState
+ INTEGER,
+ sleMplsTpTunnelCfgInfoRole
+ INTEGER,
+ sleMplsTpTunnelCfgInfoAssociateTnlName
+ OCTET STRING,
+ sleMplsTpTunnelCfgInfoDescription
+ OCTET STRING,
+ sleMplsTpTunnelCfgInfoHlspRole
+ INTEGER,
+ sleMplsTpTunnelCfgInfoHlspServerTunnelName
+ OCTET STRING,
+ sleMplsTpTunnelCfgInfoQosPolicyName
+ OCTET STRING
+ }
+
+ sleMplsTpTunnelCfgInfoIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify an entry in this table."
+ ::= { sleMplsTpTunnelCfgInfoEntry 1 }
+
+
+ sleMplsTpTunnelCfgInfoName OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The canonical name assigned to the tunnel. This name
+ can be used to refer to the tunnel on the LSR's
+ console port. If mplsTunnelIsIf is set to true
+ then the ifName of the interface corresponding to
+ this tunnel should have a value equal to
+ mplsTunnelName. Also see the description of ifName
+ in RFC 2863."
+ REFERENCE
+ "RFC 2863 - The Interfaces Group MIB, McCloghrie, K.,
+ and F. Kastenholtz, June 2000."
+ DEFVAL { "" }
+ ::= { sleMplsTpTunnelCfgInfoEntry 2 }
+
+
+ sleMplsTpTunnelCfgInfoId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Uniquely identifies a set of tunnel instances
+ between a pair of ingress and egress LSRs.
+ Managers should obtain new values for row
+ creation in this table by reading
+ mplsTunnelIndexNext. When
+ the MPLS signalling protocol is rsvp(2) this value
+ SHOULD be equal to the value signaled in the
+ Tunnel Id of the Session object. When the MPLS
+ signalling protocol is crldp(3) this value
+ SHOULD be equal to the value signaled in the
+ LSP ID."
+ ::= { sleMplsTpTunnelCfgInfoEntry 3 }
+
+
+ sleMplsTpTunnelCfgInfoSrcIdType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ietf(1),
+ itut(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the ietf or itut type."
+ ::= { sleMplsTpTunnelCfgInfoEntry 4 }
+
+
+ sleMplsTpTunnelCfgInfoSrcGId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This Object is used to display the GlobalID of IETF"
+ ::= { sleMplsTpTunnelCfgInfoEntry 5 }
+
+
+ sleMplsTpTunnelCfgInfoSrcCc OBJECT-TYPE
+ SYNTAX MplsCcId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This Object is used to display the Source CC-ID of ITUT"
+ ::= { sleMplsTpTunnelCfgInfoEntry 6 }
+
+
+ sleMplsTpTunnelCfgInfoSrcIcc OBJECT-TYPE
+ SYNTAX MplsIccId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This Object is used to set the Source ICC-ID of ITUT"
+ ::= { sleMplsTpTunnelCfgInfoEntry 7 }
+
+
+ sleMplsTpTunnelCfgInfoSrcNodeId OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This Object is used to display the Source Node ID of IETF and ITUT"
+ ::= { sleMplsTpTunnelCfgInfoEntry 8 }
+
+
+ sleMplsTpTunnelCfgInfoDestIdType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ietf(1),
+ itut(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the ietf or itut type."
+ ::= { sleMplsTpTunnelCfgInfoEntry 9 }
+
+
+ sleMplsTpTunnelCfgInfoDestGId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This Object is used to set the Destination GlobalID of IETF"
+ ::= { sleMplsTpTunnelCfgInfoEntry 10 }
+
+
+ sleMplsTpTunnelCfgInfoDestCc OBJECT-TYPE
+ SYNTAX MplsCcId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This Object is used to display the Destination CC-ID of ITUT"
+ ::= { sleMplsTpTunnelCfgInfoEntry 11 }
+
+
+ sleMplsTpTunnelCfgInfoDestIcc OBJECT-TYPE
+ SYNTAX MplsIccId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This Object is used to set the Destination ICC-ID of ITUT"
+ ::= { sleMplsTpTunnelCfgInfoEntry 12 }
+
+
+ sleMplsTpTunnelCfgInfoDestNodeId OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This Object is used to display the Destination Node ID of IETF and ITUT"
+ ::= { sleMplsTpTunnelCfgInfoEntry 13 }
+
+
+ sleMplsTpTunnelCfgInfoMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ none(0),
+ unidirectional(1),
+ bidirectional(2),
+ corouted(3),
+ associate(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Tunnel Mode"
+ ::= { sleMplsTpTunnelCfgInfoEntry 14 }
+
+
+ sleMplsTpTunnelCfgInfoFwdInLabel OBJECT-TYPE
+ SYNTAX MplsLabel
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to display the Forward In Label.
+ The lable range is 0 to 1048575. Here 0 to 15 are
+ reserved labels. User allowed range is 16 to 1048575..
+
+ The default value 1048576 is invalid label "
+ DEFVAL { 1048576 }
+ ::= { sleMplsTpTunnelCfgInfoEntry 15 }
+
+
+ sleMplsTpTunnelCfgInfoFwdInIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Forward IN Interface index "
+ ::= { sleMplsTpTunnelCfgInfoEntry 16 }
+
+
+ sleMplsTpTunnelCfgInfoFwdOperation OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ none(0),
+ push(1),
+ pop(2),
+ swap(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Forward Ilm OPeration ."
+ ::= { sleMplsTpTunnelCfgInfoEntry 17 }
+
+
+ sleMplsTpTunnelCfgInfoFwdOutLabel OBJECT-TYPE
+ SYNTAX MplsLabel
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to display the Forward In Label.
+ The lable range is 0 to 1048575. Here 0 to 15 are
+ reserved labels. User allowed range is 16 to 1048575.
+
+ The default value 1048576 is invalid label "
+ DEFVAL { 1048576 }
+ ::= { sleMplsTpTunnelCfgInfoEntry 18 }
+
+
+ sleMplsTpTunnelCfgInfoFwdOutIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Forward OUT Interface index "
+ ::= { sleMplsTpTunnelCfgInfoEntry 19 }
+
+
+ sleMplsTpTunnelCfgInfoFwdOutMac OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to display the Forward OUT MAC ADDRESS "
+ ::= { sleMplsTpTunnelCfgInfoEntry 20 }
+
+
+ sleMplsTpTunnelCfgInfoRevInLabel OBJECT-TYPE
+ SYNTAX MplsLabel
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to display the Forward In Label.
+ The lable range is 0 to 1048575. Here 0 to 15 are
+ reserved labels. User allowed range is 16 to 1048575.
+
+ The default value 1048576 is invalid label "
+ DEFVAL { 1048576 }
+ ::= { sleMplsTpTunnelCfgInfoEntry 21 }
+
+
+ sleMplsTpTunnelCfgInfoRevInIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Reverse IN Interface index "
+ ::= { sleMplsTpTunnelCfgInfoEntry 22 }
+
+
+ sleMplsTpTunnelCfgInfoRevOperation OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ none(0),
+ push(1),
+ pop(2),
+ swap(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Reverse Ilm OPeration ."
+ ::= { sleMplsTpTunnelCfgInfoEntry 23 }
+
+
+ sleMplsTpTunnelCfgInfoRevOutLabel OBJECT-TYPE
+ SYNTAX MplsLabel
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to display the Forward In Label.
+ The lable range is 0 to 1048575. Here 0 to 15 are
+ reserved labels. User allowed range is 16 to 1048575.
+
+ The default value 1048576 is invalid label "
+ DEFVAL { 1048576 }
+ ::= { sleMplsTpTunnelCfgInfoEntry 24 }
+
+
+ sleMplsTpTunnelCfgInfoRevOutIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Reverse OUT Interface index "
+ ::= { sleMplsTpTunnelCfgInfoEntry 25 }
+
+
+ sleMplsTpTunnelCfgInfoRevOutMac OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to display the Forward OUT MAC ADDRESS ."
+ ::= { sleMplsTpTunnelCfgInfoEntry 26 }
+
+
+ sleMplsTpTunnelCfgInfoState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ up(1),
+ down(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is to display status of the tunnel."
+ ::= { sleMplsTpTunnelCfgInfoEntry 27 }
+
+
+ sleMplsTpTunnelCfgInfoRole OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ source(0),
+ transist(1),
+ destination(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is to display Role of the tunnel."
+ ::= { sleMplsTpTunnelCfgInfoEntry 28 }
+
+
+ sleMplsTpTunnelCfgInfoAssociateTnlName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object to display associate of reverse tunnel."
+ ::= { sleMplsTpTunnelCfgInfoEntry 29 }
+
+
+ sleMplsTpTunnelCfgInfoDescription OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleMplsTpTunnelCfgInfoEntry 30 }
+
+
+ sleMplsTpTunnelCfgInfoHlspRole OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ server(1),
+ client(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Hlsp Tunnel. whether the tunnel is Server or client.
+ server (1) :- To set the Server Tunnel
+ client(2) :- To set the Client Tunnel ."
+ ::= { sleMplsTpTunnelCfgInfoEntry 31 }
+
+
+ sleMplsTpTunnelCfgInfoHlspServerTunnelName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the server TunnelName,
+ when sleMplsTpTunnelCfgControlHlspOption as a client ."
+ ::= { sleMplsTpTunnelCfgInfoEntry 32 }
+
+
+ sleMplsTpTunnelCfgInfoQosPolicyName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Qos Policy name."
+ ::= { sleMplsTpTunnelCfgInfoEntry 33 }
+
+
+ sleMplsTpTunnelCfgControl OBJECT IDENTIFIER ::= { sleMplsTpTunnelCfg 2 }
+
+
+ sleMplsTpTunnelCfgControlRequest OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ createMplsTpTunnelEntry(1),
+ deleteMplsTpTunnelEntry(2),
+ setMplsTpTunnelMode(3),
+ setNhlfe(4),
+ setIlmPop(5),
+ setIlmSwap(6),
+ setAssociateTunnel(7),
+ unsetNhlfe(8),
+ unsetIlmPop(9),
+ unsetIlmSwap(10),
+ unsetAssociateTunnel(11),
+ setDescription(12),
+ setHlspServerLsp(13),
+ setHlspClientLsp(14),
+ unsetHlspServerLsp(15),
+ unsetHlspClientLsp(16),
+ setTunnelQosPolicyName(17),
+ unsetTunnelQosPolicyName(18)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object holds the possible read-write columns that can be
+ modified in the Tunnel table. For each read-write column of
+ Tunnel table, a Set Operation controlvalue is added in this object."
+ ::= { sleMplsTpTunnelCfgControl 1 }
+
+
+ sleMplsTpTunnelCfgControlStatus OBJECT-TYPE
+ SYNTAX SleControlStatusType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object displays the status of the configuration done."
+ ::= { sleMplsTpTunnelCfgControl 2 }
+
+
+ sleMplsTpTunnelCfgControlTimer OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is based on the SLE style where a timer is configured
+ for every control table."
+ ::= { sleMplsTpTunnelCfgControl 3 }
+
+
+ sleMplsTpTunnelCfgControlTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the time at which the configuration is done."
+ ::= { sleMplsTpTunnelCfgControl 4 }
+
+
+ sleMplsTpTunnelCfgControlReqResult OBJECT-TYPE
+ SYNTAX SleControlRequestResultType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The standard result of the SET operation is stored here."
+ ::= { sleMplsTpTunnelCfgControl 5 }
+
+
+ sleMplsTpTunnelCfgControlName OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..16))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The canonical name assigned to the tunnel. This name
+ can be used to refer to the tunnel on the LSR's
+ console port. If mplsTunnelIsIf is set to true
+ then the ifName of the interface corresponding to
+ this tunnel should have a value equal to
+ SlemplsTunnelName. Also see the description of ifName
+ in RFC 2863."
+ REFERENCE
+ "RFC 2863 - The Interfaces Group MIB, McCloghrie, K.,
+ and F. Kastenholtz, June 2000."
+ DEFVAL { "" }
+ ::= { sleMplsTpTunnelCfgControl 6 }
+
+
+ sleMplsTpTunnelCfgControlId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the tunnel Id ."
+ ::= { sleMplsTpTunnelCfgControl 7 }
+
+
+ sleMplsTpTunnelCfgControlSrcIdType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ietf(1),
+ itut(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the ietf or itut type."
+ ::= { sleMplsTpTunnelCfgControl 8 }
+
+
+ sleMplsTpTunnelCfgControlSrcGId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the source Global-Id for IETF ."
+ ::= { sleMplsTpTunnelCfgControl 9 }
+
+
+ sleMplsTpTunnelCfgControlSrcCc OBJECT-TYPE
+ SYNTAX MplsCcId
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the source CC-ID for ITUT."
+ ::= { sleMplsTpTunnelCfgControl 10 }
+
+
+ sleMplsTpTunnelCfgControlSrcIcc OBJECT-TYPE
+ SYNTAX MplsIccId
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Source ICC-ID for ITUT."
+ ::= { sleMplsTpTunnelCfgControl 11 }
+
+
+ sleMplsTpTunnelCfgControlSrcNodeId OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Source Node-Id for IETF and ITUT"
+ ::= { sleMplsTpTunnelCfgControl 12 }
+
+
+ sleMplsTpTunnelCfgControlDestIdType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ ietf(1),
+ itut(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the ietf or itut type."
+ ::= { sleMplsTpTunnelCfgControl 13 }
+
+
+ sleMplsTpTunnelCfgControlDestGId OBJECT-TYPE
+ SYNTAX Unsigned32 (1)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Destination Global-Id for IETF ."
+ ::= { sleMplsTpTunnelCfgControl 14 }
+
+
+ sleMplsTpTunnelCfgControlDestCc OBJECT-TYPE
+ SYNTAX MplsCcId
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Destination CC-ID for ITUT."
+ ::= { sleMplsTpTunnelCfgControl 15 }
+
+
+ sleMplsTpTunnelCfgControlDestIcc OBJECT-TYPE
+ SYNTAX MplsIccId
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Destination ICC-ID for ITUT."
+ ::= { sleMplsTpTunnelCfgControl 16 }
+
+
+ sleMplsTpTunnelCfgControlDestNodeId OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Destination NodeID for IETF
+ and ITUT."
+ ::= { sleMplsTpTunnelCfgControl 17 }
+
+
+ sleMplsTpTunnelCfgControlMode OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ unidirectional(1),
+ bidirectional(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Tunnel mode ."
+ ::= { sleMplsTpTunnelCfgControl 18 }
+
+
+ sleMplsTpTunnelCfgControlPath OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ forwardPath(1),
+ reversePath(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to Set the forward path and reverse path
+ tunnel."
+ ::= { sleMplsTpTunnelCfgControl 19 }
+
+
+ sleMplsTpTunnelCfgControlInLabel OBJECT-TYPE
+ SYNTAX MplsLabel
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Inlabel. "
+ ::= { sleMplsTpTunnelCfgControl 20 }
+
+
+ sleMplsTpTunnelCfgControlInInterface OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Ininterface index."
+ ::= { sleMplsTpTunnelCfgControl 21 }
+
+
+ sleMplsTpTunnelCfgControlOperation OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ push(1),
+ pop(2),
+ swap(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the operation of Tuunel "
+ ::= { sleMplsTpTunnelCfgControl 22 }
+
+
+ sleMplsTpTunnelCfgControlOutLabel OBJECT-TYPE
+ SYNTAX MplsLabel
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the outlabel. "
+ ::= { sleMplsTpTunnelCfgControl 23 }
+
+
+ sleMplsTpTunnelCfgControlOutInterface OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the outerinterface index."
+ ::= { sleMplsTpTunnelCfgControl 24 }
+
+
+ sleMplsTpTunnelCfgControlOutMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to Set the Out MacAddress ."
+ ::= { sleMplsTpTunnelCfgControl 25 }
+
+
+ sleMplsTpTunnelCfgControlAssociateTnlName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to Associated Forward tunnel and reverse tunnel
+ with reverse tunnel name ."
+ ::= { sleMplsTpTunnelCfgControl 26 }
+
+
+ sleMplsTpTunnelCfgControlDescription OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { sleMplsTpTunnelCfgControl 27 }
+
+
+ sleMplsTpTunnelCfgControlHlspSeverTunnelName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the server Tunnel name for associating server and client."
+ ::= { sleMplsTpTunnelCfgControl 28 }
+
+
+ sleMplsTpTunnelCfgControlQosPolicyName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to set the Qos Policy name."
+ ::= { sleMplsTpTunnelCfgControl 29 }
+
+
+
+ END
+
+--
+-- sle-mpls-tp-tunnel-mib.mib
+--
|