@@ -0,0 +1,619 @@
+
+-- File Name : EquipmentCommon_MIB.mib
+-- Version : 1.01.00
+-- Date : May 1, 2015
+-- Author : DragonWave Inc.
+
+EQUIPMENT-COMMON-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
+ Counter64, IpAddress, Integer32, TimeTicks, Counter32, Unsigned32
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION, DisplayString, DateAndTime,
+ TimeStamp
+ FROM SNMPv2-TC
+ equipmentCommon
+ FROM DWI-HARMONY-PRIVATE-MIB;
+
+-- Not supported : Opaque
+-- [RFC2578]
+-- [RFC2579]
+--
+-- Module Identity
+--
+
+equipmentCommonMib MODULE-IDENTITY
+ LAST-UPDATED "200901210000Z"
+ ORGANIZATION
+ "DragonWave Inc."
+ CONTACT-INFO
+ ""
+ DESCRIPTION
+ "This MIB Module defines a notification log mechanism and a current alarm list."
+
+ REVISION "200901210000Z"
+ DESCRIPTION
+ "Initial Revision"
+
+ REVISION "201501051615Z"
+ DESCRIPTION
+ "Corrected EquipmentAlarmActiveTable index order."
+::= { equipmentCommon 100 }
+
+
+--
+-- History of MIB Changes
+--
+--
+--
+-- Textual conventions
+--
+
+EnableType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Enabled/Disabled"
+ SYNTAX INTEGER {
+ disabled (0),
+ enabled (1)
+ }
+
+
+--
+-- Node definitions
+--
+
+equipmentCommonObjects OBJECT IDENTIFIER ::= { equipmentCommon 1 }
+equipmentConfigLog OBJECT IDENTIFIER ::= { equipmentCommonObjects 1 }
+equipmentLog OBJECT IDENTIFIER ::= { equipmentCommonObjects 2 }
+equipmentAlarmList OBJECT IDENTIFIER ::= { equipmentCommonObjects 3 }
+equipmentSnmpTrap OBJECT IDENTIFIER ::= { equipmentCommonObjects 4 }
+equipmentPseudoEventsObjects OBJECT IDENTIFIER ::= { equipmentCommon 2 }
+equipmentMirrorObjects OBJECT IDENTIFIER ::= { equipmentCommon 3 }
+
+--
+-- Object definitions: configuration section
+--
+
+equipmentEventLogEntryLimit OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of notification entries that may be held
+ in EventLogTable."
+ DEFVAL { 4096 }
+ ::= { equipmentConfigLog 1 }
+
+--
+-- Object definitions: event log section
+--
+
+equipmentEventLogLastEntry OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of equipmentEventLogIndex at the time of the last
+ creation of an entry in the equipmentEventLogTable."
+ ::= { equipmentLog 1 }
+
+--
+-- Event Notification Log Table (inspired by RFC 3014)
+--
+
+equipmentEventLogTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EquipmentEventLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of Notification log entries."
+ ::= { equipmentLog 2 }
+
+equipmentEventLogEntry OBJECT-TYPE
+ SYNTAX EquipmentEventLogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A Notification log entry. Entries appear in this table
+ when Notifications occur. They are removed to make way
+ for new entries due to lack of resources or the values of
+ equipmentEventLogEntryLimit.If adding an entry would exceed
+ equipmentEventLogEntryLimit the oldest entry in that log SHOULD
+ be removed to make room for the new one."
+ INDEX { equipmentEventLogIndex }
+ ::= { equipmentEventLogTable 1 }
+
+EquipmentEventLogEntry ::= SEQUENCE {
+ equipmentEventLogIndex
+ Unsigned32,
+ equipmentEventLogTime
+ TimeStamp,
+ equipmentEventLogDateAndTime
+ DateAndTime,
+ equipmentEventLogNotificationID
+ OBJECT IDENTIFIER,
+ equipmentEventLogVariables
+ Unsigned32
+}
+
+equipmentEventLogIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A monotonically increasing integer for the sole purpose of
+ indexing entries within the log. When it reaches the
+ maximum value,the agent wraps the value back to 1.
+ This number should correspond to the number of notifications
+ sent by the agent."
+ ::= { equipmentEventLogEntry 1 }
+
+equipmentEventLogTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when the entry was placed in the log."
+ ::= { equipmentEventLogEntry 2 }
+
+equipmentEventLogDateAndTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The local date and time when the entry was logged, useful when browsing the MIB."
+ ::= { equipmentEventLogEntry 3 }
+
+equipmentEventLogNotificationID OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The NOTIFICATION-TYPE object identifier of the Notification that
+ occurred."
+ ::= { equipmentEventLogEntry 4 }
+
+equipmentEventLogVariables OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of variables in equipmentEventLogVariableTable for this
+ logged notification."
+ ::= { equipmentEventLogEntry 5 }
+
+--
+-- Event Log variable Table
+--
+
+equipmentEventLogVariableTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EquipmentEventLogVariableEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of variables to go with Notification log entries."
+ ::= { equipmentLog 3 }
+
+equipmentEventLogVariableEntry OBJECT-TYPE
+ SYNTAX EquipmentEventLogVariableEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A Notification log entry variable.
+
+ Entries appear in this table when there are variables in
+ the varbind list of a Notification in equipmentEventLogTable."
+ INDEX { equipmentEventLogIndex,
+ equipmentEventLogVariableIndex }
+ ::= { equipmentEventLogVariableTable 1 }
+
+EquipmentEventLogVariableEntry ::= SEQUENCE {
+ equipmentEventLogVariableIndex
+ Unsigned32,
+ equipmentEventLogVariableID
+ OBJECT IDENTIFIER,
+ equipmentEventLogVariableValueType
+ INTEGER,
+ equipmentEventLogVariableCounter32Val
+ Counter32,
+ equipmentEventLogVariableUnsigned32Val
+ Unsigned32,
+ equipmentEventLogVariableTimeTicksVal
+ TimeTicks,
+ equipmentEventLogVariableInteger32Val
+ Integer32,
+ equipmentEventLogVariableOctetStringVal
+ OCTET STRING,
+ equipmentEventLogVariableIpAddressVal
+ IpAddress,
+ equipmentEventLogVariableOidVal
+ OBJECT IDENTIFIER,
+ equipmentEventLogVariableCounter64Val
+ Counter64
+}
+
+equipmentEventLogVariableIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A monotonically increasing integer, starting at 1 for a given
+ equipmentEventLogIndex, for indexing variables within the logged
+ Event Notification."
+ ::= { equipmentEventLogVariableEntry 1 }
+
+equipmentEventLogVariableID OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The variable's object identifier."
+ ::= { equipmentEventLogVariableEntry 2 }
+
+equipmentEventLogVariableValueType OBJECT-TYPE
+ SYNTAX INTEGER {
+ counter32 (1),
+ unsigned32 (2),
+ timeTicks (3),
+ integer32 (4),
+ ipAddress (5),
+ octetString (6),
+ objectId (7),
+ counter64 (8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of the value. One and only one of the value
+ objects that follow must be instantiated, based on this type."
+ ::= { equipmentEventLogVariableEntry 3 }
+
+-- Not supported: opaque(9)
+
+equipmentEventLogVariableCounter32Val OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when equipmentEventLogVariableValueType is 'counter32'."
+ ::= { equipmentEventLogVariableEntry 4 }
+
+equipmentEventLogVariableUnsigned32Val OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when equipmentEventLogVariableValueType is 'unsigned32'."
+ ::= { equipmentEventLogVariableEntry 5 }
+
+equipmentEventLogVariableTimeTicksVal OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when equipmentEventLogVariableValueType is 'timeTicks'."
+ ::= { equipmentEventLogVariableEntry 6 }
+
+equipmentEventLogVariableInteger32Val OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when equipmentEventLogVariableValueType is 'integer32'."
+ ::= { equipmentEventLogVariableEntry 7 }
+
+equipmentEventLogVariableOctetStringVal OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when equipmentEventLogVariableValueType is 'octetString'."
+ ::= { equipmentEventLogVariableEntry 8 }
+
+equipmentEventLogVariableIpAddressVal OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when equipmentEventLogVariableValueType is 'ipAddress'.
+ Although this seems to be unfriendly for IPv6, we
+ have to recognize that there are a number of older
+ MIBs that do contain an IPv4 format address, known
+ as IpAddress.
+
+ IPv6 addresses are represented using TAddress or
+ InetAddress, and so the underlying datatype is
+ OCTET STRING, and their value would be stored in
+ the equipmentEventLogVariableOctetStringVal column."
+ ::= { equipmentEventLogVariableEntry 9 }
+
+equipmentEventLogVariableOidVal OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when equipmentEventLogVariableValueType is 'objectId'."
+ ::= { equipmentEventLogVariableEntry 10 }
+
+equipmentEventLogVariableCounter64Val OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value when equipmentEventLogVariableValueType is 'counter64'."
+ ::= { equipmentEventLogVariableEntry 11 }
+
+--
+-- Opaque type not supported
+--
+-- equipmentEventLogVariableOpaqueVal OBJECT-TYPE
+-- SYNTAX Opaque
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "The value when equipmentEventLogVariableValueType is 'opaque'."
+-- ::= { equipmentEventLogVariableEntry 12 }
+--
+-- Object definitions: active alarm list section
+--
+--
+-- Active Alarm Table
+--
+
+equipmentAlarmActiveLastChanged OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime at the time of the last
+ creation or deletion of an entry in the equipmentAlarmActiveTable.
+ Useful in case of polling (no traps mechanism used).
+ If the number of entries has been unchanged since the
+ last re-initialization, then this object contains a zero value."
+ ::= { equipmentAlarmList 1 }
+
+equipmentAlarmActiveRowCounter OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of active alarms row in the table."
+ ::= { equipmentAlarmList 2 }
+
+equipmentAlarmActiveTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EquipmentAlarmActiveEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of Active Alarms entries."
+ ::= { equipmentAlarmList 3 }
+
+equipmentAlarmActiveEntry OBJECT-TYPE
+ SYNTAX EquipmentAlarmActiveEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entries appear in this table when alarms are raised. They
+ are removed when the alarm is cleared."
+ INDEX { equipmentAlarmActiveIndex,
+ equipmentAlarmActiveTime }
+ ::= { equipmentAlarmActiveTable 1 }
+
+EquipmentAlarmActiveEntry ::= SEQUENCE {
+ equipmentAlarmActiveIndex
+ Unsigned32,
+ equipmentAlarmActiveTime
+ TimeStamp,
+ equipmentAlarmActiveDateAndTime
+ DateAndTime,
+ equipmentAlarmActiveName
+ DisplayString,
+ equipmentAlarmActiveID
+ Integer32,
+ equipmentAlarmActiveInstance
+ Unsigned32,
+ equipmentAlarmActiveTrapOID
+ OBJECT IDENTIFIER,
+ equipmentAlarmActiveSeverity
+ INTEGER,
+ equipmentAlarmActiveConditionId
+ DisplayString
+}
+
+equipmentAlarmActiveIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A strictly monotonically increasing integer which
+ acts as the index of entries within the named alarm
+ list. It wraps back to 1 after it reaches its
+ maximum value."
+ ::= { equipmentAlarmActiveEntry 1 }
+
+equipmentAlarmActiveTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when the entry was placed in the list.
+ This object facilitates retrieving all instances of
+ alarms that have been raised or have changed state
+ since a given point in time."
+ ::= { equipmentAlarmActiveEntry 2 }
+
+equipmentAlarmActiveDateAndTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The local date and time when the error occurred.
+
+ This object facilitates retrieving all instances of
+ alarms that have been raised or have changed state
+ since a given point in time.
+
+ Implementations MUST include the offset from UTC,
+ if available. Implementation in environments in which
+ the UTC offset is not available is NOT RECOMMENDED."
+ ::= { equipmentAlarmActiveEntry 3 }
+
+equipmentAlarmActiveName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the active alarm name."
+ ::= { equipmentAlarmActiveEntry 4 }
+
+equipmentAlarmActiveID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the active alarm ID which is the index to the alarm configuration table defined in product specific MIB."
+ ::= { equipmentAlarmActiveEntry 5 }
+
+equipmentAlarmActiveInstance OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { equipmentAlarmActiveEntry 6 }
+
+equipmentAlarmActiveTrapOID OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The MIB object identifier of the alarm (contained in an Alarm Notification
+ type object) that is occurring."
+ ::= { equipmentAlarmActiveEntry 7 }
+
+equipmentAlarmActiveSeverity OBJECT-TYPE
+ SYNTAX INTEGER {
+ warning (1),
+ minor (2),
+ major (3),
+ critical (4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the active alarm severity."
+ ::= { equipmentAlarmActiveEntry 8 }
+
+equipmentAlarmActiveConditionId OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { equipmentAlarmActiveEntry 9 }
+
+--
+-- Opaque type not supported
+--
+-- equipmentAlarmActiveSourceOpaqueVal OBJECT-TYPE
+-- SYNTAX Opaque
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "The value when value type is 'opaque'.It is coded as follows:
+-- code: OCTET STRING(SIZE(1)), fixed to 1 (structure identifier);
+-- type: INTEGER, see equipmentEventLogVariableValueType values;
+-- value: ASN.1 basic encoding rule"
+-- ::= { equipmentAlarmActiveEntry 5 }
+--
+-- Object definitions: trap counter and timestamp
+--
+
+equipmentOutTrapsCounter OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The counter of the output traps.
+ It increases by one every time a new trap is sent to all the managers configured
+ in the relevant table. In this way its value is the number of notification events
+ occurred since the last agent reset and every manager that reads this value can understand
+ whether some event has been lost or not.
+ (Note that in general this counter differs from the RFC1213 snmpOutTraps, that counts the
+ number of Trap PDUs sent). When the logging mechanism is enabled, it corresponds to the index in the eventlog table"
+ ::= { equipmentSnmpTrap 1 }
+
+equipmentLastOutTrapTimeStamp OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when the last trap was sent."
+ ::= { equipmentSnmpTrap 2 }
+
+equipmentTrapInfo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A string representing additional info that can be used as the varbind in trap. "
+ ::= { equipmentSnmpTrap 3 }
+
+--
+-- Object definitions: pseudo-events support
+--
+
+equipmentConfChangeOid OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The OID of the last node changed. It is sent to the managers in order to
+ notify a configuration change."
+ ::= { equipmentPseudoEventsObjects 1 }
+
+equipmentConfChangeMode OBJECT-TYPE
+ SYNTAX EnableType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/Disable of sending ConfChange Trap.
+ STORAGE: permanent."
+ DEFVAL { enabled }
+ ::= { equipmentPseudoEventsObjects 2 }
+
+equipmentConfChangeNotification NOTIFICATION-TYPE
+ OBJECTS { equipmentConfChangeOid,
+ equipmentOutTrapsCounter }
+ STATUS current
+ DESCRIPTION
+ "Notification of configuration change."
+ ::= { equipmentPseudoEventsObjects 3 }
+
+--
+-- Object definitions: mirror-traps support
+--
+
+equipmentMirrorFlag OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fixed to 1=mirror trap"
+ ::= { equipmentMirrorObjects 1 }
+
+equipmentMirrorColdStart NOTIFICATION-TYPE
+ OBJECTS { equipmentMirrorFlag,
+ equipmentOutTrapsCounter }
+ STATUS current
+ DESCRIPTION
+ "A coldStart trap signifies that the SNMP entity,
+ supporting a notification originator application, is
+ reinitializing itself and that its configuration may
+ have been altered."
+ ::= { equipmentMirrorObjects 2 }
+END
+
+