diff options
Diffstat (limited to 'MIBS/enterasys/CT-HSIMPHYS-MIB')
| -rw-r--r-- | MIBS/enterasys/CT-HSIMPHYS-MIB | 343 |
1 files changed, 343 insertions, 0 deletions
diff --git a/MIBS/enterasys/CT-HSIMPHYS-MIB b/MIBS/enterasys/CT-HSIMPHYS-MIB new file mode 100644 index 0000000..b24ba41 --- /dev/null +++ b/MIBS/enterasys/CT-HSIMPHYS-MIB @@ -0,0 +1,343 @@ +CT-HSIMPHYS-MIB DEFINITIONS ::= BEGIN + + -- ct-hsimphys-mib.txt + -- Revision: 01.00.00 + -- Part Number: + -- Date: July 21, 1998 + + -- Cabletron Systems, Inc. + -- 35 Industrial Way, P.O. Box 5005 + -- Rochester, NH 03867-0505 + -- (603) 332-9400 + -- support@ctron.com + + -- This module provides an enterprise-specific HSIM container MIB. + -- + -- This module will be extended, as needed. + -- + + -- Cabletron Systems reserves the right to make changes in + -- specification and other information contained in this document + -- without prior notice. The reader should consult Cabletron Systems + -- to determine whether any such changes have been made. + -- + -- In no event shall Cabletron Systems be liable for any incidental, + -- indirect, special, or consequential damages whatsoever (including + -- but not limited to lost profits) arising out of or related to this + -- document or the information contained in it, even if Cabletron + -- Systems has been advised of, known, or should have known, the + -- possibility of such damages. + -- + -- Cabletron grants vendors, end-users, and other interested parties + -- a non-exclusive license to use this Specification in connection + -- with the management of Cabletron products. + + -- Copyright March 98 Cabletron Systems + + -- This MIB is intended to provide a central repository & link to all + -- information about the physical aspect of an HSIM. Physical info + -- includes items related to the HW inventory , BOOT, EPLD, and other + -- low level information. For the purposes of this MIB, no difference + -- is recognized between a permantly-installed "option card", such as + -- the onboard WAN interface on the HSIM-W65/75, and an actual WPIM. + + IMPORTS + OBJECT-TYPE + FROM RFC-1212 + DisplayString + FROM RFC1213-MIB + ctHSIMPhysMib + FROM CTRON-MIB-NAMES; + + + --================= HSIM Info =================== + + hsimInfo OBJECT IDENTIFIER ::= { ctHSIMPhysMib 1 } + + hsimBoardRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object is the printed circuit board + revision level." + ::= { hsimInfo 1 } + + hsimBoardId OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object is the printed circuit board + idenitifer." + ::= { hsimInfo 2 } + + hsimEpldRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object is the programmable + logic device revision level." + ::= { hsimInfo 3 } + + hsimEpldId OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object is the programmable + logic device identifier." + ::= { hsimInfo 4 } + + hsimFsbRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object is the first stage + boot revision level." + ::= { hsimInfo 5 } + + hsimSsbRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object is the second stage + boot revision level." + ::= { hsimInfo 6 } + + hsimFwRev OBJECT-TYPE + SYNTAX DisplayString + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object is the HSIM firmware + revision level." + ::= { hsimInfo 7 } + + --=================== HSIM Peripheral MBus Info ===================== + + hsimPeripheralMBusInfo OBJECT IDENTIFIER + ::= { hsimInfo 8 } + + mBusNumberBoardsInstalled OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object is number of MBus boards + installed in this unit." + ::= { hsimPeripheralMBusInfo 1 } + + mBusBoardTable OBJECT-TYPE + SYNTAX SEQUENCE OF MBusBoardEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of MBus boards present in this unit" + ::= { hsimPeripheralMBusInfo 2 } + + mBusBoardEntry OBJECT-TYPE + SYNTAX MBusBoardEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The value of this object is an MBus board that is + present in this unit" + INDEX { mBusBoardID } + ::= { mBusBoardTable 1 } + + MBusBoardEntry ::= + SEQUENCE { + mBusBoardID INTEGER, + mBusBoardEntryType INTEGER, + mBusBoardOIDPointer OBJECT IDENTIFIER + } + + mBusBoardID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object is an index that uniquely + identifies the physical MBus board within the system." + ::= { mBusBoardEntry 1 } + + mBusBoardEntryType OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + cmm(2) + } + + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object identifies the type of MBus + board installed." + ::= { mBusBoardEntry 2 } + + mBusBoardOIDPointer OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object defines the start of a MIB that + can be used to determine more specific information about + the given MBus board." + ::= { mBusBoardEntry 3 } + + + --=================== HSIM Peripheral WPIM Info ===================== + + hsimPeripheralWpimInfo OBJECT IDENTIFIER + ::= { hsimInfo 9 } + + wpimNumberBoardsInstalled OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object is number of WPIM boards + installed in this unit." + ::= { hsimPeripheralWpimInfo 1 } + + wpimBoardTable OBJECT-TYPE + SYNTAX SEQUENCE OF WpimBoardEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of WPIM boards present in this unit" + ::= { hsimPeripheralWpimInfo 2 } + + wpimBoardEntry OBJECT-TYPE + SYNTAX WpimBoardEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The value of this object is a WPIM board that is + present in this unit" + INDEX { wpimBoardID } + ::= { wpimBoardTable 1 } + + WpimBoardEntry ::= + SEQUENCE { + wpimBoardID INTEGER, + wpimBoardEntryType OBJECT IDENTIFIER, + wpimBoardOIDPointer OBJECT IDENTIFIER + } + + wpimBoardID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object is an index that uniquely + identifies this WPIM board." + ::= { wpimBoardEntry 1 } + + wpimBoardEntryType OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object identifies the type of WPIM + board installed. This is within the portWpim branch + of the namingTree (1.3.6.1.4.1.52.3.8.1.2.5)" + ::= { wpimBoardEntry 2 } + + wpimBoardOIDPointer OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object defines the start of a MIB that + can be used to determine more specific information about + the given WPIM board." + ::= { wpimBoardEntry 3 } + + --=================== HSIM Local HW Devices Info ===================== + + hsimLocalHwDevicesInfo OBJECT IDENTIFIER + ::= { hsimInfo 10 } + + localHwDevicesTable OBJECT-TYPE + SYNTAX SEQUENCE OF LocalHwDevicesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of specific hardware devices present in this unit" + ::= { hsimLocalHwDevicesInfo 1 } + + localHwDevicesEntry OBJECT-TYPE + SYNTAX LocalHwDevicesEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The value of this object is a WPIM module that is + present in this unit" + INDEX { localHwDeviceID } + ::= { localHwDevicesTable 1 } + + LocalHwDevicesEntry ::= + SEQUENCE { + localHwDeviceID INTEGER, + localHwDeviceType INTEGER, + localHwDeviceOperStatus INTEGER, + localHwDeviceAdminStatus INTEGER + } + + localHwDeviceID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object is an index that uniquely + identifies the assoicated local hardware device." + ::= { localHwDevicesEntry 1 } + + localHwDeviceType OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + siemensMunich32(2), + mitelMT8985(3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object identifies the type of local + hardware device. These local hardware devices are those + specific ICs unique to this HSIM such as Siemens + Munich32, or Mitel MT8985." + ::= { localHwDevicesEntry 2 } + + localHwDeviceOperStatus OBJECT-TYPE + SYNTAX INTEGER { + up(1), -- ready to pass packets + down(2), + testing(3), -- in some test mode + unknown(4), -- status can not be determined + -- for some reason. + dormant(5) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object describes the current state of the device." + ::= { localHwDevicesEntry 3 } + + localHwDeviceAdminStatus OBJECT-TYPE + SYNTAX INTEGER { + up(1), -- ready execute + down(2), + testing(3) -- in some test mode + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This object is used by the Network Management System to + request a change in the current state of the device." + ::= { localHwDevicesEntry 4 } + +END |