diff options
Diffstat (limited to 'MIBS/exalt/ExaltComProducts')
| -rw-r--r-- | MIBS/exalt/ExaltComProducts | 1740 |
1 files changed, 1740 insertions, 0 deletions
diff --git a/MIBS/exalt/ExaltComProducts b/MIBS/exalt/ExaltComProducts new file mode 100644 index 0000000..661318b --- /dev/null +++ b/MIBS/exalt/ExaltComProducts @@ -0,0 +1,1740 @@ +ExaltComProducts DEFINITIONS ::= BEGIN + IMPORTS + MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, + IpAddress, Integer32, Gauge32 + FROM SNMPv2-SMI + exaltcommunications, EthMainStatusT, EthAuxStatusT, AuxNmsMode, + EthPortMode, Te1StatusT, Te1LboT, EnableStatusT, + Te1LineCodeT, Te1LoopBackModeT, AlarmLevelT, + Led4ColorT, VlanStatusT, VlanGroupT, ExaltEnableT, AcmModulationT, + FileTransferTypeT, FileTransferStartT, NtpClientEnableT, TimeZoneT + FROM ExaltComm + OBJECT-GROUP + FROM SNMPv2-CONF + DisplayString, TEXTUAL-CONVENTION + FROM SNMPv2-TC; + + productsMIB MODULE-IDENTITY + LAST-UPDATED "201304291021Z" + ORGANIZATION "Exalt" + CONTACT-INFO "Exalt Wireless Inc. + 250 E Hacienda Ave., + Campbell, CA, 95008 + USA" + + DESCRIPTION "Exalt devices" + + REVISION "201304291021Z" + DESCRIPTION "This is the Exalt Products mib. rev:1.01" + ::= { exaltcommunications 1 } + + PwType ::= TEXTUAL-CONVENTION + DISPLAY-HINT "255a" + STATUS current + DESCRIPTION "This is a PW field." + SYNTAX OCTET STRING (SIZE(8..16)) + + + + productsMIBNotifications OBJECT IDENTIFIER ::= { productsMIB 1 } + + productsMIBObjects OBJECT IDENTIFIER ::= { productsMIB 2 } + + radioInfo OBJECT-IDENTITY + STATUS current + DESCRIPTION "Common Radio Information to all Exalt devices." + ::= { productsMIBObjects 1 } + + modelName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..20)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "A descriptive name for the Radio. See Web, Radio Information, Model Name." + ::= { radioInfo 1 } + + partNumber OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..20)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Part Number of the Radio. See Web, Radio Information, Part Number." + ::= { radioInfo 2 } + + serialNumber OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..20)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Radio Serial Number. See Web, Radio Inforamtion, Serial Number." + ::= { radioInfo 3 } + + interfaceType OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..30)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Interfaces available on this radio. Ethernet, T1/E1, etc. + See Web, Radio Information, Interface Type." + ::= { radioInfo 4 } + + firmwareVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Radio Firmware Version. See Web, Radio Information, Firmware Version." + ::= { radioInfo 5 } + + bootVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Radio Boot Code Version. See Web, Radio Information, Boot Version." + ::= { radioInfo 6 } + + rdkDbVer OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Device RDK Database Version. See Web, Radio Information, RDK Database Version." + ::= { radioInfo 11 } + + txFreqRange OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Radio Tx Frequency Range. + FDD radios have a Tx and Rx frequency range. + See Web, Radio Information, RF Transmit range. + TDD radios have one frequency range. + See Web, Radio Information, RF Frequency Band." + ::= { radioInfo 12 } + + rxFreqRange OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Radio Rx Frequency Range. + FDD radios have a Tx and Rx frequency range. + See Web, Radio Information, RF Receive range. + TDD radios have one frequency range. + See Web, Radio Information, RF Frequency Band." + ::= { radioInfo 13 } + + rfFreqBand OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Device Frequency Band (Range). + TDD radios have N/A value in this field. + FDD radios have TX High or TX Low depending on used diplexer and Transmit frequency. + See Web, Radio Information, Tx Band." + ::= { radioInfo 14 } + + hwId OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Device Hardware ID number. See Web, Radio Information, Hardware ID number" + ::= { radioInfo 15 } + + modelNumber OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Model Number of the Radio. See Web, Radio Information, Model Number" + ::= { radioInfo 16 } + + licenseFeatures OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..128)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The list of the features enabled by License Key" + ::= { radioInfo 17 } + + radioAdmin OBJECT-IDENTITY + STATUS current + DESCRIPTION "Radio Administration parameters." + ::= { productsMIBObjects 2 } + + sysDate OBJECT-TYPE + SYNTAX DisplayString (SIZE(10)) + UNITS "MM/DD/YYYY" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The Radio System Date, MM/DD/YYYY. See Web, Administration, Settings, Date. + To make permanent, write save to commitAdminSettings after change. + After commit, SNMP restarts and will be down for 30 seconds." + ::= { radioAdmin 1 } + + sysTime OBJECT-TYPE + SYNTAX DisplayString (SIZE(8)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The Radio System Time, HH:MM:SS, as 24 hours. See Web, Administration, Settings, Time. + To make permanent, write save to commitAdminSettings after change. + After commit, SNMP restarts and will be down for 30 seconds." + ::= { radioAdmin 2 } + + radioName OBJECT IDENTIFIER ::= { radioAdmin 3 } + + rnLocal OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The user specifiable Radio Name for this radio. + See Web, Administration, Settings, Radio Name. + To make permanent, write save to commitAdminSettings after change." + ::= { radioName 1 } + + rnRemote OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Radio Name of the Radio at the far end of this RF Link. + Can only be set at that radio. See Web, Administration, Settings, Radio Name." + ::= { radioName 2 } + + linkName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The user specifiable Link Name for this radio. + See Web, Administration, Settings, Link Name. + To make permanent, write save to commitAdminSettings after change." + ::= { radioAdmin 4 } + + linkSecKey OBJECT-TYPE + SYNTAX DisplayString (SIZE(12)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The Link Security Key must match on both ends of an RF Link for traffic to pass. + See Web, Administration, Settings, Link Security Key. + To make permanent, write save to commitAdminSettings after change." + ::= { radioAdmin 5 } + + adminPassword OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..16)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The password for admin login to Web/CLI. + See Web, Administration, Settings, Admin Password. + To make permanent, write save to commitAdminSettings after change." + ::= { radioAdmin 6 } + + userPassword OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..16)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The password for user login to Web/CLI. + See Web, Administration, Settings, User Password. + To make permanent, write save to commitAdminSettings after change." + ::= { radioAdmin 7 } + + ipAddress OBJECT IDENTIFIER ::= { radioAdmin 8 } + + ipLocal OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The IP address of local radio. + This IP address is used to manage radio. + See Web, Administration, Settings, IP Address. + To make permanent, write save to commitAdminSettings after change." + ::= { ipAddress 1 } + + ipRemote OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The IP address of the remote Radio. + This IP address is used to manage Remote radio. + Can only be set at that radio. See Web, Administration, Settings, IP Address." + ::= { ipAddress 2 } + + subnetMask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The Subnet Mask for IP address of local radio. + See Web, Administration, Settings, IP Mask. + To make permanent, write save to commitAdminSettings after change." + ::= { radioAdmin 9 } + + ipAddressNetmask OBJECT-TYPE + SYNTAX DisplayString (SIZE(9..18)) + UNITS "IP/NN Where NN=00 To 32" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The IP address and Subnet Mask of local radio. ie 10.0.0.1/24. + To make permanent, write save to commitAdminSettings after change." + ::= { radioAdmin 10 } + + defaultGateway OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The Default Gateway for local radio port. + See Web, Administration, Settings, Default Gateway. + To make permanent, write save to commitAdminSettings after change." + ::= { radioAdmin 11 } + + aesEnable OBJECT-TYPE + SYNTAX INTEGER { + aesDisable( 0 ), + aesEnable( 1 ) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The AES enable(0)/disable(1). + AES (Advance Encryption Standard) can be implemented to provide additional + data security for the wireless link. + This function requires an upgrade license key (purchased separately). + See Web, Administration, Settings, AES Settings, Enable AES. + To make permanent, write save to commitAdminSettings after change." + ::= { radioAdmin 12 } + + aesKey OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..64)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The symmetric AES key for encrypt/decrypt payload data. + Different bitlength encryption license keys (for example, 128-bit and 256-bit) + are available, depending on model type and license type. + AES Key should match both on local radio and far end radio. + See Web, Administration, Settings, AES Settings, AES Key. + To make permanent, write save to commitAdminSettings after change." + ::= { radioAdmin 13 } + + + licKey OBJECT-TYPE + SYNTAX DisplayString (SIZE(1..32)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The license key which defines radio features and capabilities. + See Web, Administration, Settings, License Key. + To make permanent, write save to commitAdminSettings after change." + ::= { radioAdmin 14 } + + -- rdkKey OBJECT-TYPE ::= { radioAdmin 15 } + -- domainName OBJECT-TYPE ::= { radioAdmin 16 } + + snmpConfig OBJECT IDENTIFIER ::= { radioAdmin 17 } + + trapIpaddr1 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The IP address to which the SNMP traps are directed. + See Web, Administration, SNMP, Traps, Trap Destination IP Address." + ::= { snmpConfig 1 } + + trapIpaddrEnable1 OBJECT-TYPE + SYNTAX EnableStatusT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Enable/Disable trap ip address." + ::= { snmpConfig 2 } + + trapIpaddr2 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The IP address to which the SNMP traps are directed. + See Web, Administration, SNMP, Traps, Trap Destination IP Address." + ::= { snmpConfig 3 } + + trapIpaddrEnable2 OBJECT-TYPE + SYNTAX EnableStatusT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable/Disable trap ip address." + ::= { snmpConfig 4 } + + trapIpaddr3 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The IP address to which the SNMP traps are directed. + See Web, Administration, SNMP, Traps, Trap Destination IP Address." + ::= { snmpConfig 5 } + + trapIpaddrEnable3 OBJECT-TYPE + SYNTAX EnableStatusT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable/Disable trap ip address." + ::= { snmpConfig 6 } + + trapIpaddr4 OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The IP address to which the SNMP traps are directed. + See Web, Administration, SNMP, Traps, Trap Destination IP Address." + ::= { snmpConfig 7 } + + trapIpaddrEnable4 OBJECT-TYPE + SYNTAX EnableStatusT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Enable/Disable trap ip address." + ::= { snmpConfig 8 } + + trapAuth OBJECT-TYPE + SYNTAX EnableStatusT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Authentication trap enable(1)/disable(0). + This is an SNMP standard trap when password information for SNMP is incorrect. + See Web, Administration, SNMP, Traps, Authentication Trap." + ::= { snmpConfig 9 } + + trapReboot OBJECT-TYPE + SYNTAX EnableStatusT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Reboot trap enable(0)/disable(1). + This trap is sent after any radio reboot to inform the manager of the reboot status. + See Web, Administration, SNMP, Traps, Radio Reboot Trap." + ::= { snmpConfig 10 } + + trapLocLinkStat OBJECT-TYPE + SYNTAX EnableStatusT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Local Link Status trap enable(0)/disable(1). + This trap is sent when Link is in errored state (equivalent to the Link LED). + See Web, Administration, SNMP, Traps, Local Link Status Trap." + ::= { snmpConfig 11 } + + trapLocAlarmStat OBJECT-TYPE + SYNTAX EnableStatusT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Local Alarm Status trap enable(0)/disable(1). + This trap is sent when local radio Status is in errored state + (equivalent to the Status LED). + See Web, Administration, SNMP, Traps, Local Radio Status Trap." + ::= { snmpConfig 12 } + + trapRemAlarmStat OBJECT-TYPE + SYNTAX EnableStatusT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Remote Alarm Status trap enable(0)/disable(1). + This trap is sent when remote radio Status is in errored state + (equivalent to the Status LED). + See Web, Administration, SNMP, Traps, Remote Radio Status Trap." + ::= { snmpConfig 13 } + + trapLocTempStat OBJECT-TYPE + SYNTAX EnableStatusT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Local Temperature Status trap enable(0)/disable(1). + This trap is sent when the internal temperature reaches the warning point. + See Web, Administration, SNMP, Traps, Temperature Status Trap." + ::= { snmpConfig 14 } + + trapv1Enable OBJECT-TYPE + SYNTAX EnableStatusT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "SNMPv1 Traps enable(0)/disable(1). + Enables traps for SNMP protocol version 1. + See Web, Administration, SNMP, Traps, Enable SNMPv1 Traps." + ::= { snmpConfig 15 } + + trapv2cEnable OBJECT-TYPE + SYNTAX EnableStatusT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "SNMPv2c Traps enable(0)/disable(1). + Enables traps for SNMP protocol version 2c. + See Web, Administration, SNMP, Traps, Enable SNMPv2c Traps." + ::= { snmpConfig 16 } + + trapv3Enable OBJECT-TYPE + SYNTAX EnableStatusT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "SNMPv3 Traps enable(0)/disable(1). + Enables traps for SNMP protocol version 3. + See Web, Administration, SNMP, Traps, Enable SNMPv3 Traps." + ::= { snmpConfig 17 } + + trapLocRslStat OBJECT-TYPE + SYNTAX EnableStatusT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Local RSL Status trap enable(0)/disable(1). + This trap is sent when the local RSL drops below the value set in the + RSL Threshold Value (dBm) field. + See Web, Administration, SNMP, Traps, Local RSL Status Trap." + ::= { snmpConfig 18 } + + trapLocRslThreshold OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Local RSL Threshold. + Exalt recommends that this trap be set to a value 5dBm or 10dBm above + the threshold as a warning that the system has faded and may be approaching an outage. + See Web, Administration, SNMP, Traps, Threshold Value." + ::= { snmpConfig 19 } + + commitSnmpSettings OBJECT-TYPE + SYNTAX DisplayString (SIZE(4..200)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Option strings to be written are: save, clear, correspondingly saving changes to + configuration to the persistent storage or clearing unsaved changes." + ::= { snmpConfig 1000 } + + + ntp OBJECT-IDENTITY + STATUS current + DESCRIPTION "NTP and Time zone configuration." + ::= { radioAdmin 18 } + + ntpClientEnable OBJECT-TYPE + SYNTAX NtpClientEnableT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "this mib to enable/disable the NTP client in the radio. + 0 - disable NTP client. + 1 - enable with 1 NTP server. + 2 - enable with 2 NTP servers. + 3 - enable with 3 NTP servers. + 4 - enable with 4 NTP servers." + + ::= { ntp 1 } + + ntpServer1IpAddr OBJECT-TYPE + SYNTAX DisplayString (SIZE(7..15)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "IP address for the first NTP server in xxx.xxx.xxx.xxx format" + + ::= { ntp 2 } + + ntpServer2IpAddr OBJECT-TYPE + SYNTAX DisplayString (SIZE(7..15)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "IP address for the second NTP server in xxx.xxx.xxx.xxx format" + ::= { ntp 3 } + + ntpServer3IpAddr OBJECT-TYPE + SYNTAX DisplayString (SIZE(7..15)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "IP address for the third NTP server in xxx.xxx.xxx.xxx format" + ::= { ntp 4 } + + ntpServer4IpAddr OBJECT-TYPE + SYNTAX DisplayString (SIZE(7..15)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "IP address for the forth NTP server in xxx.xxx.xxx.xxx format" + ::= { ntp 5 } + + ntpTimeZoneSelect OBJECT-TYPE + SYNTAX TimeZoneT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Time Zone selection. + + 0 - (GMT-11:00) Samoa + 1 - (GMT-10.00) Hawaii + 2 - (GMT-09:00) Alaska + 3 - (GMT-08:00) Pacific Time + 4 - (GMT-07:00) Arizona + 5 - (GMT-07:00) Montain Time + 6 - (GMT-06:00) Central Time + 7 - (GMT-05:00) Eastern Time + 8 - (GMT-05:00) Indiana (East) + 9 - (GMT-04:00) Atlantic Time (Canada) + 10- (GMT) Coordinated Universal Time + 11- (GMT) London + 12- (GMT+01:00) Berlin + 13- (GMT+01:00) Belgrade + 14- (GMT+01:00) Paris + 15- (GMT+02:00) Cairo + 16- (GMT+02:00) Helsinki + 17- (GMT+03:00) Baghdad + 18- (GMT+03:00) Moscow + 19- (GMT+03:30) Tehran + 20- (GMT+04:30) Kabul + 21- (GMT+05:00) Karachi + 22- (GMT+07:00) Bangkok + 23- (GMT+08:00) Shanghai + 24- (GMT+08:00) Taipei + 25- (GMT+09:00) Tokyo + 26- (GMT+09:00) Seoul + 27- (GMT+10:00) Sydney + 28- (GMT+10:00) Vladivostok" + + ::= { ntp 6 } + + commitNtpSettings OBJECT-TYPE + SYNTAX DisplayString (SIZE(4..200)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "This command allows saving or clear the NTP and Tome Zone configuration. + If the save includes the change of time zone, the radio will automatically reboot + to take effect the newly selected time zone. + Option strings to be written are: save, clear, correspondingly saving changes to + configuration to the persistent storage or clearing unsaved changes." + ::= { ntp 1000 } + + commitAdminSettings OBJECT-TYPE + SYNTAX DisplayString (SIZE(4..200)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The Commit Administration settings command. Valid values: 'save', 'clear'. + Configuration changes via SNMP do not take effect until + 'save' (Commit) command is sent to this parameter. + 'clear' (Cancel) command is used to cancel configuration changes before commit operation. + In case of invalid configuration this parameter contains text description of the problem." + ::= { radioAdmin 1000 } + + radioConfig OBJECT-IDENTITY + STATUS current + DESCRIPTION "The Radio Configuration Section." + ::= { productsMIBObjects 3 } + + systemConfig OBJECT-IDENTITY + STATUS current + DESCRIPTION "This is the device specific configuration section." + ::= { radioConfig 1 } + + commitSystemSettings OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The Commit System Configuration settings command. Valid values: 'save', 'clear'. + Configuration changes via SNMP do not take effect until + 'save' (Commit) command is sent to this parameter. + 'clear' (Cancel) command is used to cancel configuration changes before commit operation. + In case of invalid configuration this parameter contains text description of the problem." + ::= { systemConfig 1000 } + + interface OBJECT-IDENTITY + STATUS current + DESCRIPTION "Radio Interfaces Configuration section." + ::= { radioConfig 2 } + + te1 OBJECT-IDENTITY + STATUS current + DESCRIPTION "T1,E1 interfaces Configuration section. + Section allows to configure T1/E1 ports on the radio if any." + ::= { interface 2 } + + te1NumChannels OBJECT-TYPE + SYNTAX Gauge32 + UNITS "channels" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Number of T1 or E1 channels supported by the Radio." + ::= { te1 1 } + + te1NumActiveChannels OBJECT-TYPE + SYNTAX Gauge32 + UNITS "channels" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Current number of channels available, based + on bandwitdh of the RF link and the license key." + ::= { te1 2 } + + selectT1orE1 OBJECT-TYPE + SYNTAX INTEGER { + t1( 0 ), + e1( 1 ) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Select operation mode of T1/E1 interfaces. Either T1(0) or E1(1). + See Web, Configuration, Interface, T1/E1, Set To E1/T1 Mode button." + ::= { te1 3 } + + te1Interfaces OBJECT-TYPE + SYNTAX SEQUENCE OF Te1InterfacesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Attributes for T1 or E1 ports." + ::= { te1 4 } + + te1Interface OBJECT-TYPE + SYNTAX Te1InterfacesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "An entry in the T1/E1 Attribute table." + INDEX { + te1Status, t1LBO, te1AIS, t1LineCode, te1LoopBackMode + } + ::= { te1Interfaces 1 } + + Te1InterfacesEntry ::= SEQUENCE { + te1Status + Te1StatusT, + t1LBO + Te1LboT, + te1AIS + Te1StatusT, + t1LineCode + Te1LineCodeT, + te1LoopBackMode + Te1LoopBackModeT + } + + te1Status OBJECT-TYPE + SYNTAX Te1StatusT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The T1/E1 status: enable(1)/disable(0). + Parameter allows to enable/disable each individual T1 channel. + See Web, Configuration, Interface, T1/E1, Status. + To make permanent, write save to commitTe1Settings after change." + ::= { te1Interface 1 } + + t1LBO OBJECT-TYPE + SYNTAX Te1LboT + UNITS "feet" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The Line Build Out length range. + Valid values (ft): lbo0to133(0), lbo133to266(1), lbo266to399(2), lbo399to533(3), lbo533to655(4). + See Web, Configuration, Interface, T1/E1, LBO. + To make permanent, write save to commitTe1Settings after change." + ::= { te1Interface 2 } + + te1AIS OBJECT-TYPE + SYNTAX Te1StatusT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The T1/E1 AIS enabled flag: enable(1)/disable(0). + If enabled, the radio places an AIS code on the output of the associated interface + if and when the link fails or when there is no E1 signal available from the far + end to provide the user at the local end. + See Web, Configuration, Interface, T1/E1, AIS. + To make permanent, write save to commitTe1Settings after change." + ::= { te1Interface 3 } + + t1LineCode OBJECT-TYPE + SYNTAX Te1LineCodeT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The T1/E1 Line Code type: b8zs(0), ami(1). + See Web, Configuration, Interface, T1/E1, AIS, Line Code. + To make permanent, write save to commitTe1Settings after change." + ::= { te1Interface 4 } + + te1LoopBackMode OBJECT-TYPE + SYNTAX Te1LoopBackModeT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The Loop Back Mode for a T1/E1 interface. + Valid values: disabled(0), ExternalLocal(1), ExternalRemote(2), Internal(3). + All loopback configurations control the loop at the Line Interface integrated circuit, + which is the device wired directly to the front panel ports. + See Web, Configuration, Interface, T1/E1, AIS, Loopback. + To make permanent, write save to commitTe1Settings after change." + ::= { te1Interface 5 } + + commitTe1Settings OBJECT-TYPE + SYNTAX DisplayString (SIZE(4..200)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The Commit TE1 Configuration settings command. Valid values: 'save', 'clear'. + Configuration changes to TE1 ports via SNMP do not take effect until + 'save' (Commit) command is sent to this parameter. + 'clear' (Cancel) command is used to cancel configuration changes before commit operation. + In case of invalid configuration this parameter contains text description of the problem." + ::= { te1 1000 } + + fileManagement OBJECT-IDENTITY + STATUS current + DESCRIPTION "The File Management Section. + This section allows to initiate Upload/Download firmware/configuration/logs, + perform Firmware activation procedure." + ::= { radioConfig 3 } + + currentFwFilename OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..100)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The file name of the currently running firmware. + See Web, Administration, File Management, File Activation, Current File." + ::= { fileManagement 1 } + + alternateFwFilename OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..100)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The file name of the alternate firmware image. + See Web, Administration, File Management, File Activation, Alternative File." + ::= { fileManagement 2 } + + swapFWimage OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..200)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Swap the firmware images and restart radio. + To perform swap operation 'swap' command needs to be sent to this parameter. + For ExtendAirG2 to perform revert to factory operation 'factory' command needs to be sent. + Radio will become unavailable for several minutes." + ::= { fileManagement 3 } + + fileTransfer OBJECT-IDENTITY + STATUS current + DESCRIPTION "The File Transfer Section. + This section allows to initiate Upload/Download firmware/configuration/logs + over TFTP protocol." + ::= { fileManagement 4 } + + factoryFwFilename OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..100)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The file name of the factory firmware image. + See Web, Administration, File Management, File Activation, Factory File." + ::= { fileManagement 5 } + + tftpServerIp OBJECT-TYPE + SYNTAX DisplayString (SIZE(7..15)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The TFTP Server IP address. + " + ::= { fileTransfer 1 } + + uploadFilename OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..127)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The name of the file for upload operation. + For configuration file uploadFilename should be always 'config.xml'. + uploadFilename value should match the file name in TFTP server folder." + ::= { fileTransfer 2 } + + transferType OBJECT-TYPE + SYNTAX FileTransferTypeT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "The file transfer type. + Valid values: + - uploadFirmware(0) + - uploadConfig(1) + - uploadRDD(2) (Valid only for TDD radios) + - downloadFirmware(3) + - downloadConfig(4) + - downloadMIBs(5) + - downloadEventLogs(6). + The actual operation starts via updating transferStart parameter value." + ::= { fileTransfer 3 } + + transferStart OBJECT-TYPE + SYNTAX FileTransferStartT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "TransferStart parameter is used to initiate file transfer operation. + Send startTransfer(1) to this parameter." + ::= { fileTransfer 4 } + + transferStatus OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..127)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The current file transfer status." + ::= { fileTransfer 5 } + + radioMonitor OBJECT-IDENTITY + STATUS current + DESCRIPTION "Monitor Various components." + ::= { productsMIBObjects 4 } + + -- gps OBJECT IDENTIFIER ::= { radioMonitor 1 } + -- satelliteInView OBJECT-TYPE ::= { gps 1 } + alarms OBJECT IDENTIFIER ::= { radioMonitor 2 } + + + almLocal OBJECT IDENTIFIER ::= { alarms 3 } + locSysAlarms OBJECT IDENTIFIER ::= { almLocal 1 } + locEthAlarms OBJECT IDENTIFIER ::= { almLocal 2 } + locTe1Alarms OBJECT IDENTIFIER ::= { almLocal 3 } + -- gigEAlarms OBJECT IDENTIFIER ::= { locAlarms 4 } + -- locDS3Alarms OBJECT IDENTIFIER ::= { locAlarms 5 } + -- locV35Alarms OBJECT IDENTIFIER ::= { locAlarms 6 } + -- locOduAlarms OBJECT IDENTIFIER ::= { locAlarms 7 } + + locLinkState OBJECT-TYPE + SYNTAX AlarmLevelT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Link Status Alarm. + Possible values: + - almNORMAL(0) - Error-free connection (BER<10e-6) + - almMINOR(1) - Errorred connection (BER<10e-3) + - almMAJOR(2) - No link (BER>10e-3) + See Web, Monitor, Alarms, Link" + ::= { locSysAlarms 1 } + + locTempAlarm OBJECT-TYPE + SYNTAX AlarmLevelT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Temperature Alarm state. + Possible values: + - almNORMAL(0) - Normal temprature range + - almMINOR(1) - Exceeding normal temprature range + See Web, Monitor, Alarms, Temperature" + ::= { locSysAlarms 2 } + + locCurrentTemp OBJECT-TYPE + SYNTAX Integer32 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Internal Temperature in Celsius." + ::= { locSysAlarms 3 } + + locCurrentTempS OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Internal Temperature as a string. " + ::= { locSysAlarms 4 } + + -- locCollocAlarm OBJECT-TYPE ::= { locSysAlarms 8 } + -- remCollocAlarm OBJECT-TYPE ::= { remSysAlarms 8 } + + locLinkSecMismatch OBJECT-TYPE + SYNTAX AlarmLevelT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This is link security mismatch alarm. + This alarm tells if the Link Security Key is matching or not. + Possible values: + - almNORMAL(0) - Link Secutiry keys match + - almMAJOR(2) - Link Secutiry keys do not match + " + ::= { locSysAlarms 9 } + + locLinkStateV OBJECT-TYPE + SYNTAX AlarmLevelT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Vertical Link Status Alarm. -<g89><>" + ::= { locSysAlarms 15 } + + locLinkStateH OBJECT-TYPE + SYNTAX AlarmLevelT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Horizontal Link Status Alarm. -<g89><>" + ::= { locSysAlarms 16 } + +-- T1/E1 + locTe1LinkSummary OBJECT-TYPE + SYNTAX Led4ColorT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The T1/E1 Link Summary LED color. " + ::= { locTe1Alarms 1 } + + locTE1Alarms OBJECT-TYPE + SYNTAX SEQUENCE OF Te1Alarms1Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "The Local T1/E1 Interface Alarms." + ::= { locTe1Alarms 2 } + + locTe1AlarmsEntry OBJECT-TYPE + SYNTAX Te1Alarms1Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "T1/E1 Alarms table Entry." + INDEX { + locTe1Alarm + } + ::= { locTE1Alarms 1 } + + Te1Alarms1Entry ::= SEQUENCE { + locTe1Alarm + AlarmLevelT + } + + locTe1Alarm OBJECT-TYPE + SYNTAX AlarmLevelT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Alarms state for the Local T1/E1 Channel. + Possible values: + - almNORMAL(0) - Enabled and connection present + - almMAJOR(2) - Enabled and no connection present + - almDisable(3) - Disabled and no connection present + - almNotAvailable(4) - T1/E1 channel is not available + See Web, Monitor, Alarms, T1/E1 Input" + ::= { locTe1AlarmsEntry 1 } + +-- end of te1 local alarms + + almRemote OBJECT IDENTIFIER ::= { alarms 4 } + remSysAlarms OBJECT IDENTIFIER ::= { almRemote 1 } + remEthAlarms OBJECT IDENTIFIER ::= { almRemote 2 } + remTe1Alarms OBJECT IDENTIFIER ::= { almRemote 3 } + + remLinkState OBJECT-TYPE + SYNTAX AlarmLevelT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Link Status Alarm for far end radio. + Possible values: + - almNORMAL(0) - Error-free connection (BER<10e-6) + - almMINOR(1) - Errorred connection (BER<10e-3) + - almMAJOR(2) - No link (BER>10e-3) + - almNotAvailable(4) - Telemetry is down + See Web, Monitor, Alarms, Link" + ::= { remSysAlarms 1 } + + remTempAlarm OBJECT-TYPE + SYNTAX AlarmLevelT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Temperature Alarm state for far end radio. + Possible values: + - almNORMAL(0) - Normal temprature range + - almMINOR(1) - Exceeding normal temprature range + - almNotAvailable(4) - Telemetry is down + See Web, Monitor, Alarms, Temperature" + ::= { remSysAlarms 2 } + + remCurrentTemp OBJECT-TYPE + SYNTAX Integer32 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Internal Temperature in Celsius for far end radio. " + ::= { remSysAlarms 3 } + + remCurrentTempS OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The internal Temperature as a string for far end radio. " + ::= { remSysAlarms 4 } + +-- remCollocAlarm OBJECT-TYPE ::= { remSysAlarms 8 } + + remLinkSecMismatch OBJECT-TYPE + SYNTAX AlarmLevelT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This is link security mismatch alarm. + This alarm tells if the Link Security Key is matching or not. + Possible values: + - almNORMAL(0) - Link Secutiry keys match + - almMAJOR(2) - Link Secutiry keys do not match + - almNotAvailable(4) - Telemetry is down + " + ::= { remSysAlarms 9 } + + remLinkStateV OBJECT-TYPE + SYNTAX AlarmLevelT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Vertical Link Status Alarm. -<g89><>" + ::= { remSysAlarms 15 } + + remLinkStateH OBJECT-TYPE + SYNTAX AlarmLevelT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Horizontal Link Status Alarm. -<g89><>" + ::= { remSysAlarms 16 } + +-- remote Te1 alarms + remTe1LinkSummary OBJECT-TYPE + SYNTAX Led4ColorT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The T1/E1 Link Summary LED color. " + ::= { remTe1Alarms 1 } + + remTE1Alarms OBJECT-TYPE + SYNTAX SEQUENCE OF Te1AlarmsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "The Remotel T1/E1 Interface Alarms." + ::= { remTe1Alarms 2 } + + remTe1AlarmsEntry OBJECT-TYPE + SYNTAX Te1AlarmsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "T1/E1 Alarms table Entry." + INDEX { + remTe1Alarm + } + ::= { remTE1Alarms 1 } + + Te1AlarmsEntry ::= SEQUENCE { + remTe1Alarm + AlarmLevelT + } + + remTe1Alarm OBJECT-TYPE + SYNTAX AlarmLevelT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Alarms state for the Local T1/E1 Channel of far end radio. + Possible values: + - almNORMAL(0) - Enabled and connection present + - almMAJOR(2) - Enabled and no connection present + - almDisable(3) - Disabled and no connection present + - almNotAvailable(4) - Telemetry is down or T1/E1 channel is not available + See Web, Monitor, Alarms, T1/E1 Input" + ::= { remTe1AlarmsEntry 1 } + +-- end remote Te1 alarms + + + performance OBJECT IDENTIFIER ::= { radioMonitor 3 } + + perfLocal OBJECT IDENTIFIER ::= { performance 1 } + + perfRemote OBJECT IDENTIFIER ::= { performance 2 } + + + locCurrentBER OBJECT-TYPE + SYNTAX Integer32 + UNITS "BER * 1000000.0" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Curent Bit-Error Rate as scaled integer for local radio. + The BER multiplied by 1,000,000. + If the link is operating perfectly, this should indicate zero. + See Web, Monitor, Performance, Current BER" + ::= { perfLocal 1 } + + locCurrentBERstr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Current Bit-Error Rate as a string. " + ::= { perfLocal 2 } + + locCurrentRSL OBJECT-TYPE + SYNTAX Integer32 + UNITS "dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current RSL is the measurement of the received signal level. + When the RSL falls below the threshold specification, + the link disconnects and will not reconnect until + the RSL is above the threshold specification. + See Web, Monitor, Performance, Current RSL" + ::= { perfLocal 3 } + + locCurrentRSLstr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Current RSL as a string." + ::= { perfLocal 4 } + + locErrorDuration OBJECT-TYPE + SYNTAX Integer32 + UNITS "Seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Error Duration indicates the total number of seconds that occurred where + there was at least one bit error since the last time that + the radio statistics counter was reset. + See Web, Monitor, Performance, Errored Seconds" + ::= { perfLocal 5 } + + locErrorDurationStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Error Duration as a formatted string." + ::= { perfLocal 6 } + + locUnavailDuration OBJECT-TYPE + SYNTAX Integer32 + UNITS "Seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Unavailable Duration keeps track of every second where the BER equals or exceeds 1x10-3, + as well as any seconds where there is a complete loss of radio communication. + See Web, Monitor, Performance, Unavailable Seconds" + ::= { perfLocal 7 } + + locUnavailDurationStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Unavailable Duration as a formatted string." + ::= { perfLocal 8 } + + locMinRSL OBJECT-TYPE + SYNTAX Integer32 + UNITS "dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Minimum RSL indicates the worst (lowest) received signal level + that occurred since the last counter reset. + See Web, Monitor, Performance, Minimum RSL" + ::= { perfLocal 9 } + + locMinRSLstr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Minimum RSL value as a string." + ::= { perfLocal 10 } + + locMinRSLtimestamp OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Minimum RSL Timestamp indicates the date and time when the Minimum RSL occurred. + See Web, Monitor, Performance, Minimum RSL Timestamp" + ::= { perfLocal 11 } + + locMaxRSL OBJECT-TYPE + SYNTAX Integer32 + UNITS "dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Maximum RSL indicates the best (highest) RSL + that occurred since the last counter reset. + See Web, Monitor, Performance, Maximum RSL" + ::= { perfLocal 12 } + + locMaxRSLstr OBJECT-TYPE + SYNTAX DisplayString + UNITS "dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Maximum RSL level As string." + ::= { perfLocal 13 } + + locSampleDuration OBJECT-TYPE + SYNTAX Integer32 + UNITS "Seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Sample Duration indicates the amount of time passed since the last counter reset. + See Web, Monitor, Performance, Time Since Reset" + ::= { perfLocal 14 } + + locSampleDurationStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Sample Duration value as a formatted string." + ::= { perfLocal 15 } + + locEthPerfInterfaces OBJECT-TYPE + SYNTAX SEQUENCE OF LocEthPerfInterfacesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Performance characteristics of local Ethernet interfaces" + ::= { perfLocal 16 } + + locEthPerfInterfacesEntry OBJECT-TYPE + SYNTAX LocEthPerfInterfacesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "An entry in the Performance characteristics of local Ethernet interfaces table" + INDEX { + locEthUtilizationIn, + locEthUtilizationOut, + locEthSpeed + } + ::= { locEthPerfInterfaces 1 } + + LocEthPerfInterfacesEntry ::= SEQUENCE { + locEthUtilizationIn Integer32, + locEthUtilizationOut Integer32, + locEthSpeed DisplayString + } + + locEthUtilizationIn OBJECT-TYPE + SYNTAX Integer32 (0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Inbound ethernet utilization (%). + See Web, Analysis, Ethernet Utilization." + ::= { locEthPerfInterfacesEntry 1 } + + locEthUtilizationOut OBJECT-TYPE + SYNTAX Integer32 (0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Outbound ethernet utilization (%). + See Web, Analysis, Ethernet Utilization." + ::= { locEthPerfInterfacesEntry 2 } + + locEthSpeed OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Ethernet Speed. + See Web, Monitor, Ethernet Performance." + ::= { locEthPerfInterfacesEntry 3 } + + locEthUtilizationWatermarkEnabled OBJECT-TYPE + SYNTAX ExaltEnableT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Ethernet utilization watermark enable(1)/disable(0). + See Web, Analysis, Ethernet Utilization, Ethernet Utilization Watermark." + ::= { perfLocal 17 } + + locEthUtilizationWatermark OBJECT-TYPE + SYNTAX Integer32 (0..100) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Ethernet utilization watermark level (%). + See Web, Analysis, Ethernet Utilization, Watermark level." + ::= { perfLocal 18 } + + locEthUtilizationWatermarkTrapEnabled OBJECT-TYPE + SYNTAX ExaltEnableT + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Ethernet utilization watermark trap enable(1)/disable(0). + The watermark trap function allows administrators to receive an SNMP trap + when watermark conditions are exceeded. + See Web, Analysis, Ethernet Utilization, Enable Ethernet Utilization Trap." + ::= { perfLocal 19 } + + locEthUtilizationWatermarkTrapDuration OBJECT-TYPE + SYNTAX Integer32 (0..1440) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Ethernet utilization trap limit in minutes/day (0-1440 minutes). + See Web, Analysis, Ethernet Utilization, Send trap if watermark hit duration exceeds." + ::= { perfLocal 20 } + + locMaximumTxModulation OBJECT-TYPE + SYNTAX AcmModulationT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The highest/maximum Tx modulation when ACM is enabled since the last counter reset. + See Web, Monitor, Performance, Tx modulation." + ::= { perfLocal 100 } + + locActiveTxModulation OBJECT-TYPE + SYNTAX AcmModulationT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The active Tx modulation when ACM is enabled. + See Web, Monitor, Performance, Tx modulation." + ::= { perfLocal 101 } + + locMinimumTxModulation OBJECT-TYPE + SYNTAX AcmModulationT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The lowest/minimum Tx modulation when ACM is enabled since the last counter reset. + See Web, Monitor, Performance, Tx modulation." + ::= { perfLocal 102 } + + + locMaximumRxModulation OBJECT-TYPE + SYNTAX AcmModulationT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The highest/maximum Rx modulation when ACM is enabled since the last counter reset. + See Web, Monitor, Performance, Rx modulation." + ::= { perfLocal 103 } + + + locActiveRxModulation OBJECT-TYPE + SYNTAX AcmModulationT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The active Rx modulation when ACM is enabled. + See Web, Monitor, Performance, Rx modulation." + ::= { perfLocal 104 } + + + locMinimumRxModulation OBJECT-TYPE + SYNTAX AcmModulationT + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The lowest/minimum Rx modulation when ACM is enabled since the last counter reset. + See Web, Monitor, Performance, Rx modulation." + ::= { perfLocal 105 } + + + -- + -- ACM Tx/Rx Ethernet throughtput + -- + + locMaximumTxEthernetThroughput OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The highest/maximum Tx Ethernet throughput in Mbps when ACM is enabled + since the last counter reset. + See Web, Monitor, Performance, Tx Ethernet Throughput." + ::= { perfLocal 106 } + + + locActiveTxEthernetThroughput OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The active Tx Ethernet throughput in Mbps when ACM is enabled. + See Web, Monitor, Performance, Tx Ethernet Throughput." + ::= { perfLocal 107 } + + + locMinimumTxEthernetThroughput OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The lowest/minimum Tx Ethernet throughput in Mbps when ACM is enabled + since the last counter reset. + See Web, Monitor, Performance, Tx Ethernet Throughput." + ::= { perfLocal 108 } + + + locMaximumRxEthernetThroughput OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The highest/maximum Rx Ethernet throughput in Mbps when ACM is enabled + since the last counter reset. + See Web, Monitor, Performance, Rx Ethernet Throughput." + ::= { perfLocal 109 } + + + locActiveRxEthernetThroughput OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The active Rx Ethernet throughput in Mbps when ACM is enabled. + See Web, Monitor, Performance, Rx Ethernet Throughput." + ::= { perfLocal 110 } + + + locMinimumRxEthernetThroughput OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The lowest/minimum Rx Ethernet throughput in Mbps when ACM is enabled + since the last counter reset. + See Web, Monitor, Performance, Rx Ethernet Throughput." + ::= { perfLocal 111 } + + locResetStats OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Write 'reset' to locResetStats to clear the Performance statistics." + ::= { perfLocal 1000 } + + + remCurrentBER OBJECT-TYPE + SYNTAX Integer32 + UNITS "BER * 1000000.0" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Curent Bit-Error Rate as scaled integer for far end radio. + The BER multiplied by 1,000,000. + If the link is operating perfectly, this should indicate zero. + See Web, Monitor, Performance, Current BER" + ::= { perfRemote 1 } + + remCurrentBERstr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Current Bit-Error Rate as a string. Far end radio" + ::= { perfRemote 2 } + + remCurrentRSL OBJECT-TYPE + SYNTAX Integer32 + UNITS "dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current RSL is the measurement of the received signal level. + When the RSL falls below the threshold specification, + the link disconnects and will not reconnect until + the RSL is above the threshold specification. + See Web, Monitor, Performance, Current RSL" + ::= { perfRemote 3 } + + remCurrentRSLstr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Current RSL as a string." + ::= { perfRemote 4 } + + remErrorDuration OBJECT-TYPE + SYNTAX Integer32 + UNITS "Seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Error Duration indicates the total number of seconds that occurred where + there was at least one bit error since the last time that + the radio statistics counter was reset. + See Web, Monitor, Performance, Errored Seconds, Remote column." + ::= { perfRemote 5 } + + remErrorDurationStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Error Duration as a formatted string. Far end radio." + ::= { perfRemote 6 } + + remUnavailDuration OBJECT-TYPE + SYNTAX Integer32 + UNITS "Seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Unavailable Duration keeps track of every second where the BER equals or exceeds 1x10-3, + as well as any seconds where there is a complete loss of radio communication. + See Web, Monitor, Performance, Unavailable Seconds" + ::= { perfRemote 7 } + + remUnavailDurationStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Unavailable Duration as a formatted string. Far end radio." + ::= { perfRemote 8 } + + remMinRSL OBJECT-TYPE + SYNTAX Integer32 + UNITS "dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Minimum RSL indicates the worst (lowest) received signal level + that occurred since the last counter reset. + See Web, Monitor, Performance, Minimum RSL, Remote column." + ::= { perfRemote 9 } + + remMinRSLstr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Minimum RSL value as a string. Far end radio." + ::= { perfRemote 10 } + + remMinRSLtimestamp OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Minimum RSL Timestamp indicates the date and time when the Minimum RSL occurred. + See Web, Monitor, Performance, Minimum RSL Timestamp, Remote column." + ::= { perfRemote 11 } + + remMaxRSL OBJECT-TYPE + SYNTAX Integer32 + UNITS "dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Maximum RSL indicates the best (highest) RSL + that occurred since the last counter reset. + See Web, Monitor, Performance, Maximum RSL, Remote column." + ::= { perfRemote 12 } + + remMaxRSLstr OBJECT-TYPE + SYNTAX DisplayString + UNITS "dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Maximum RSL level As string. Far end radio." + ::= { perfRemote 13 } + + remSampleDuration OBJECT-TYPE + SYNTAX Integer32 + UNITS "Seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Sample Duration indicates the amount of time passed since the last counter reset. + See Web, Monitor, Performance, Time Since Reset, Remote column." + ::= { perfRemote 14 } + + remSampleDurationStr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Sample Duration value as a formatted string. Far end radio." + ::= { perfRemote 15 } + + remResetStats OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Write 'reset' to remResetStats to clear the Performance statistics." + ::= { perfRemote 1000 } + + userThroughput OBJECT IDENTIFIER ::= { radioMonitor 5 } + + aggregateUserThroughput OBJECT-TYPE + SYNTAX DisplayString + UNITS "MBit/s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Aggregated User Throughput. + For FDD radios this parameter is always equal to fullDuplexEthernetThroughput." + ::= { userThroughput 1 } + + inboundEthernetThroughput OBJECT-TYPE + SYNTAX DisplayString + UNITS "MBit/s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Inbound Ethernet Throughput. + For FDD radios this parameter is always N/A." + ::= { userThroughput 2 } + + outboundEthernetThroughput OBJECT-TYPE + SYNTAX DisplayString + UNITS "MBit/s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Outbound Ethernet Throughput. + For FDD radios this parameter is always N/A." + ::= { userThroughput 3 } + + fullDuplexEthernetThroughput OBJECT-TYPE + SYNTAX DisplayString + UNITS "MBit/s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "The Full Duplex Ethernet Throughput is determined by + the combination of settings for Mode and Bandwidth. + See Web, Monitor, User Throughput, Full Duplex Ethernet Throughput." + ::= { userThroughput 4 } + + radioReboot OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..100)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Reboot the radio device. + Send 'reboot' to radioReboot parameter to reboot the radio device." + ::= { productsMIBObjects 1000 } + + productsMIBConformance OBJECT IDENTIFIER ::= { productsMIB 3 } + + productsMIBCompliances OBJECT IDENTIFIER ::= { productsMIBConformance 1 } + + productsMIBGroups OBJECT IDENTIFIER ::= { productsMIBConformance 2 } + + productsAllObjects OBJECT-GROUP + OBJECTS { + modelName, + partNumber, + serialNumber, + interfaceType, + firmwareVersion, + bootVersion, + rfFreqBand, + sysDate, + sysTime, + rnLocal, + rnRemote, + linkName, + linkSecKey, + adminPassword, + userPassword, + ipLocal, + ipRemote, + subnetMask, + ipAddressNetmask, + defaultGateway, + commitAdminSettings, + te1NumChannels, + te1NumActiveChannels, + selectT1orE1, + commitTe1Settings, + currentFwFilename, + alternateFwFilename, + swapFWimage, + locLinkState, + locLinkStateV, + locLinkStateH, + locTe1LinkSummary, + locTempAlarm, + locCurrentTemp, + locCurrentTempS, + locLinkSecMismatch, + remLinkState, + remLinkStateV, + remLinkStateH, + remTe1LinkSummary, + remTempAlarm, + remCurrentTemp, + remCurrentTempS, + remLinkSecMismatch, + locCurrentBER, + locCurrentBERstr, + locCurrentRSL, + locCurrentRSLstr, + locErrorDuration, + locErrorDurationStr, + locUnavailDuration, + locUnavailDurationStr, + locMinRSL, + locMinRSLstr, + locMinRSLtimestamp, + locMaxRSL, + locMaxRSLstr, + locSampleDuration, + locSampleDurationStr, + locResetStats, + remCurrentBER, + remCurrentBERstr, + remCurrentRSL, + remCurrentRSLstr, + remErrorDuration, + remErrorDurationStr, + remUnavailDuration, + remUnavailDurationStr, + remMinRSL, + remMinRSLstr, + remMinRSLtimestamp, + remMaxRSL, + remMaxRSLstr, + remSampleDuration, + remSampleDurationStr, + remResetStats, + radioReboot, + te1Status, + t1LBO, + te1AIS, + t1LineCode, + te1LoopBackMode, + locTe1Alarm, + remTe1Alarm, + aesEnable, + licKey, + aggregateUserThroughput, + inboundEthernetThroughput, + outboundEthernetThroughput, + fullDuplexEthernetThroughput, + locEthUtilizationIn, + locEthUtilizationOut, + locEthUtilizationWatermarkEnabled, + locEthUtilizationWatermark, + locEthUtilizationWatermarkTrapEnabled, + locEthUtilizationWatermarkTrapDuration + } + STATUS current + DESCRIPTION "This automatically created object group contains + all those objects that do not belong to any other + OBJECT-GROUP" + ::= { productsMIBGroups 1 } + +END + |