summaryrefslogtreecommitdiff
path: root/MIBS/exalt/ExaltComProducts
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/exalt/ExaltComProducts')
-rw-r--r--MIBS/exalt/ExaltComProducts1740
1 files changed, 1740 insertions, 0 deletions
diff --git a/MIBS/exalt/ExaltComProducts b/MIBS/exalt/ExaltComProducts
new file mode 100644
index 0000000..661318b
--- /dev/null
+++ b/MIBS/exalt/ExaltComProducts
@@ -0,0 +1,1740 @@
+ExaltComProducts DEFINITIONS ::= BEGIN
+ IMPORTS
+ MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE,
+ IpAddress, Integer32, Gauge32
+ FROM SNMPv2-SMI
+ exaltcommunications, EthMainStatusT, EthAuxStatusT, AuxNmsMode,
+ EthPortMode, Te1StatusT, Te1LboT, EnableStatusT,
+ Te1LineCodeT, Te1LoopBackModeT, AlarmLevelT,
+ Led4ColorT, VlanStatusT, VlanGroupT, ExaltEnableT, AcmModulationT,
+ FileTransferTypeT, FileTransferStartT, NtpClientEnableT, TimeZoneT
+ FROM ExaltComm
+ OBJECT-GROUP
+ FROM SNMPv2-CONF
+ DisplayString, TEXTUAL-CONVENTION
+ FROM SNMPv2-TC;
+
+ productsMIB MODULE-IDENTITY
+ LAST-UPDATED "201304291021Z"
+ ORGANIZATION "Exalt"
+ CONTACT-INFO "Exalt Wireless Inc.
+ 250 E Hacienda Ave.,
+ Campbell, CA, 95008
+ USA"
+
+ DESCRIPTION "Exalt devices"
+
+ REVISION "201304291021Z"
+ DESCRIPTION "This is the Exalt Products mib. rev:1.01"
+ ::= { exaltcommunications 1 }
+
+ PwType ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "255a"
+ STATUS current
+ DESCRIPTION "This is a PW field."
+ SYNTAX OCTET STRING (SIZE(8..16))
+
+
+
+ productsMIBNotifications OBJECT IDENTIFIER ::= { productsMIB 1 }
+
+ productsMIBObjects OBJECT IDENTIFIER ::= { productsMIB 2 }
+
+ radioInfo OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION "Common Radio Information to all Exalt devices."
+ ::= { productsMIBObjects 1 }
+
+ modelName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..20))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "A descriptive name for the Radio. See Web, Radio Information, Model Name."
+ ::= { radioInfo 1 }
+
+ partNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..20))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Part Number of the Radio. See Web, Radio Information, Part Number."
+ ::= { radioInfo 2 }
+
+ serialNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..20))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Radio Serial Number. See Web, Radio Inforamtion, Serial Number."
+ ::= { radioInfo 3 }
+
+ interfaceType OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..30))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Interfaces available on this radio. Ethernet, T1/E1, etc.
+ See Web, Radio Information, Interface Type."
+ ::= { radioInfo 4 }
+
+ firmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Radio Firmware Version. See Web, Radio Information, Firmware Version."
+ ::= { radioInfo 5 }
+
+ bootVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Radio Boot Code Version. See Web, Radio Information, Boot Version."
+ ::= { radioInfo 6 }
+
+ rdkDbVer OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Device RDK Database Version. See Web, Radio Information, RDK Database Version."
+ ::= { radioInfo 11 }
+
+ txFreqRange OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Radio Tx Frequency Range.
+ FDD radios have a Tx and Rx frequency range.
+ See Web, Radio Information, RF Transmit range.
+ TDD radios have one frequency range.
+ See Web, Radio Information, RF Frequency Band."
+ ::= { radioInfo 12 }
+
+ rxFreqRange OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Radio Rx Frequency Range.
+ FDD radios have a Tx and Rx frequency range.
+ See Web, Radio Information, RF Receive range.
+ TDD radios have one frequency range.
+ See Web, Radio Information, RF Frequency Band."
+ ::= { radioInfo 13 }
+
+ rfFreqBand OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Device Frequency Band (Range).
+ TDD radios have N/A value in this field.
+ FDD radios have TX High or TX Low depending on used diplexer and Transmit frequency.
+ See Web, Radio Information, Tx Band."
+ ::= { radioInfo 14 }
+
+ hwId OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Device Hardware ID number. See Web, Radio Information, Hardware ID number"
+ ::= { radioInfo 15 }
+
+ modelNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Model Number of the Radio. See Web, Radio Information, Model Number"
+ ::= { radioInfo 16 }
+
+ licenseFeatures OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The list of the features enabled by License Key"
+ ::= { radioInfo 17 }
+
+ radioAdmin OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION "Radio Administration parameters."
+ ::= { productsMIBObjects 2 }
+
+ sysDate OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(10))
+ UNITS "MM/DD/YYYY"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The Radio System Date, MM/DD/YYYY. See Web, Administration, Settings, Date.
+ To make permanent, write save to commitAdminSettings after change.
+ After commit, SNMP restarts and will be down for 30 seconds."
+ ::= { radioAdmin 1 }
+
+ sysTime OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(8))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The Radio System Time, HH:MM:SS, as 24 hours. See Web, Administration, Settings, Time.
+ To make permanent, write save to commitAdminSettings after change.
+ After commit, SNMP restarts and will be down for 30 seconds."
+ ::= { radioAdmin 2 }
+
+ radioName OBJECT IDENTIFIER ::= { radioAdmin 3 }
+
+ rnLocal OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The user specifiable Radio Name for this radio.
+ See Web, Administration, Settings, Radio Name.
+ To make permanent, write save to commitAdminSettings after change."
+ ::= { radioName 1 }
+
+ rnRemote OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Radio Name of the Radio at the far end of this RF Link.
+ Can only be set at that radio. See Web, Administration, Settings, Radio Name."
+ ::= { radioName 2 }
+
+ linkName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The user specifiable Link Name for this radio.
+ See Web, Administration, Settings, Link Name.
+ To make permanent, write save to commitAdminSettings after change."
+ ::= { radioAdmin 4 }
+
+ linkSecKey OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(12))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The Link Security Key must match on both ends of an RF Link for traffic to pass.
+ See Web, Administration, Settings, Link Security Key.
+ To make permanent, write save to commitAdminSettings after change."
+ ::= { radioAdmin 5 }
+
+ adminPassword OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..16))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The password for admin login to Web/CLI.
+ See Web, Administration, Settings, Admin Password.
+ To make permanent, write save to commitAdminSettings after change."
+ ::= { radioAdmin 6 }
+
+ userPassword OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..16))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The password for user login to Web/CLI.
+ See Web, Administration, Settings, User Password.
+ To make permanent, write save to commitAdminSettings after change."
+ ::= { radioAdmin 7 }
+
+ ipAddress OBJECT IDENTIFIER ::= { radioAdmin 8 }
+
+ ipLocal OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address of local radio.
+ This IP address is used to manage radio.
+ See Web, Administration, Settings, IP Address.
+ To make permanent, write save to commitAdminSettings after change."
+ ::= { ipAddress 1 }
+
+ ipRemote OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The IP address of the remote Radio.
+ This IP address is used to manage Remote radio.
+ Can only be set at that radio. See Web, Administration, Settings, IP Address."
+ ::= { ipAddress 2 }
+
+ subnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The Subnet Mask for IP address of local radio.
+ See Web, Administration, Settings, IP Mask.
+ To make permanent, write save to commitAdminSettings after change."
+ ::= { radioAdmin 9 }
+
+ ipAddressNetmask OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(9..18))
+ UNITS "IP/NN Where NN=00 To 32"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address and Subnet Mask of local radio. ie 10.0.0.1/24.
+ To make permanent, write save to commitAdminSettings after change."
+ ::= { radioAdmin 10 }
+
+ defaultGateway OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The Default Gateway for local radio port.
+ See Web, Administration, Settings, Default Gateway.
+ To make permanent, write save to commitAdminSettings after change."
+ ::= { radioAdmin 11 }
+
+ aesEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ aesDisable( 0 ),
+ aesEnable( 1 )
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The AES enable(0)/disable(1).
+ AES (Advance Encryption Standard) can be implemented to provide additional
+ data security for the wireless link.
+ This function requires an upgrade license key (purchased separately).
+ See Web, Administration, Settings, AES Settings, Enable AES.
+ To make permanent, write save to commitAdminSettings after change."
+ ::= { radioAdmin 12 }
+
+ aesKey OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..64))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The symmetric AES key for encrypt/decrypt payload data.
+ Different bitlength encryption license keys (for example, 128-bit and 256-bit)
+ are available, depending on model type and license type.
+ AES Key should match both on local radio and far end radio.
+ See Web, Administration, Settings, AES Settings, AES Key.
+ To make permanent, write save to commitAdminSettings after change."
+ ::= { radioAdmin 13 }
+
+
+ licKey OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The license key which defines radio features and capabilities.
+ See Web, Administration, Settings, License Key.
+ To make permanent, write save to commitAdminSettings after change."
+ ::= { radioAdmin 14 }
+
+ -- rdkKey OBJECT-TYPE ::= { radioAdmin 15 }
+ -- domainName OBJECT-TYPE ::= { radioAdmin 16 }
+
+ snmpConfig OBJECT IDENTIFIER ::= { radioAdmin 17 }
+
+ trapIpaddr1 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address to which the SNMP traps are directed.
+ See Web, Administration, SNMP, Traps, Trap Destination IP Address."
+ ::= { snmpConfig 1 }
+
+ trapIpaddrEnable1 OBJECT-TYPE
+ SYNTAX EnableStatusT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Enable/Disable trap ip address."
+ ::= { snmpConfig 2 }
+
+ trapIpaddr2 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address to which the SNMP traps are directed.
+ See Web, Administration, SNMP, Traps, Trap Destination IP Address."
+ ::= { snmpConfig 3 }
+
+ trapIpaddrEnable2 OBJECT-TYPE
+ SYNTAX EnableStatusT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Enable/Disable trap ip address."
+ ::= { snmpConfig 4 }
+
+ trapIpaddr3 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address to which the SNMP traps are directed.
+ See Web, Administration, SNMP, Traps, Trap Destination IP Address."
+ ::= { snmpConfig 5 }
+
+ trapIpaddrEnable3 OBJECT-TYPE
+ SYNTAX EnableStatusT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Enable/Disable trap ip address."
+ ::= { snmpConfig 6 }
+
+ trapIpaddr4 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The IP address to which the SNMP traps are directed.
+ See Web, Administration, SNMP, Traps, Trap Destination IP Address."
+ ::= { snmpConfig 7 }
+
+ trapIpaddrEnable4 OBJECT-TYPE
+ SYNTAX EnableStatusT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Enable/Disable trap ip address."
+ ::= { snmpConfig 8 }
+
+ trapAuth OBJECT-TYPE
+ SYNTAX EnableStatusT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Authentication trap enable(1)/disable(0).
+ This is an SNMP standard trap when password information for SNMP is incorrect.
+ See Web, Administration, SNMP, Traps, Authentication Trap."
+ ::= { snmpConfig 9 }
+
+ trapReboot OBJECT-TYPE
+ SYNTAX EnableStatusT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Reboot trap enable(0)/disable(1).
+ This trap is sent after any radio reboot to inform the manager of the reboot status.
+ See Web, Administration, SNMP, Traps, Radio Reboot Trap."
+ ::= { snmpConfig 10 }
+
+ trapLocLinkStat OBJECT-TYPE
+ SYNTAX EnableStatusT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Local Link Status trap enable(0)/disable(1).
+ This trap is sent when Link is in errored state (equivalent to the Link LED).
+ See Web, Administration, SNMP, Traps, Local Link Status Trap."
+ ::= { snmpConfig 11 }
+
+ trapLocAlarmStat OBJECT-TYPE
+ SYNTAX EnableStatusT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Local Alarm Status trap enable(0)/disable(1).
+ This trap is sent when local radio Status is in errored state
+ (equivalent to the Status LED).
+ See Web, Administration, SNMP, Traps, Local Radio Status Trap."
+ ::= { snmpConfig 12 }
+
+ trapRemAlarmStat OBJECT-TYPE
+ SYNTAX EnableStatusT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Remote Alarm Status trap enable(0)/disable(1).
+ This trap is sent when remote radio Status is in errored state
+ (equivalent to the Status LED).
+ See Web, Administration, SNMP, Traps, Remote Radio Status Trap."
+ ::= { snmpConfig 13 }
+
+ trapLocTempStat OBJECT-TYPE
+ SYNTAX EnableStatusT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Local Temperature Status trap enable(0)/disable(1).
+ This trap is sent when the internal temperature reaches the warning point.
+ See Web, Administration, SNMP, Traps, Temperature Status Trap."
+ ::= { snmpConfig 14 }
+
+ trapv1Enable OBJECT-TYPE
+ SYNTAX EnableStatusT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "SNMPv1 Traps enable(0)/disable(1).
+ Enables traps for SNMP protocol version 1.
+ See Web, Administration, SNMP, Traps, Enable SNMPv1 Traps."
+ ::= { snmpConfig 15 }
+
+ trapv2cEnable OBJECT-TYPE
+ SYNTAX EnableStatusT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "SNMPv2c Traps enable(0)/disable(1).
+ Enables traps for SNMP protocol version 2c.
+ See Web, Administration, SNMP, Traps, Enable SNMPv2c Traps."
+ ::= { snmpConfig 16 }
+
+ trapv3Enable OBJECT-TYPE
+ SYNTAX EnableStatusT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "SNMPv3 Traps enable(0)/disable(1).
+ Enables traps for SNMP protocol version 3.
+ See Web, Administration, SNMP, Traps, Enable SNMPv3 Traps."
+ ::= { snmpConfig 17 }
+
+ trapLocRslStat OBJECT-TYPE
+ SYNTAX EnableStatusT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Local RSL Status trap enable(0)/disable(1).
+ This trap is sent when the local RSL drops below the value set in the
+ RSL Threshold Value (dBm) field.
+ See Web, Administration, SNMP, Traps, Local RSL Status Trap."
+ ::= { snmpConfig 18 }
+
+ trapLocRslThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Local RSL Threshold.
+ Exalt recommends that this trap be set to a value 5dBm or 10dBm above
+ the threshold as a warning that the system has faded and may be approaching an outage.
+ See Web, Administration, SNMP, Traps, Threshold Value."
+ ::= { snmpConfig 19 }
+
+ commitSnmpSettings OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(4..200))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Option strings to be written are: save, clear, correspondingly saving changes to
+ configuration to the persistent storage or clearing unsaved changes."
+ ::= { snmpConfig 1000 }
+
+
+ ntp OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION "NTP and Time zone configuration."
+ ::= { radioAdmin 18 }
+
+ ntpClientEnable OBJECT-TYPE
+ SYNTAX NtpClientEnableT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "this mib to enable/disable the NTP client in the radio.
+ 0 - disable NTP client.
+ 1 - enable with 1 NTP server.
+ 2 - enable with 2 NTP servers.
+ 3 - enable with 3 NTP servers.
+ 4 - enable with 4 NTP servers."
+
+ ::= { ntp 1 }
+
+ ntpServer1IpAddr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(7..15))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "IP address for the first NTP server in xxx.xxx.xxx.xxx format"
+
+ ::= { ntp 2 }
+
+ ntpServer2IpAddr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(7..15))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "IP address for the second NTP server in xxx.xxx.xxx.xxx format"
+ ::= { ntp 3 }
+
+ ntpServer3IpAddr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(7..15))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "IP address for the third NTP server in xxx.xxx.xxx.xxx format"
+ ::= { ntp 4 }
+
+ ntpServer4IpAddr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(7..15))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "IP address for the forth NTP server in xxx.xxx.xxx.xxx format"
+ ::= { ntp 5 }
+
+ ntpTimeZoneSelect OBJECT-TYPE
+ SYNTAX TimeZoneT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Time Zone selection.
+
+ 0 - (GMT-11:00) Samoa
+ 1 - (GMT-10.00) Hawaii
+ 2 - (GMT-09:00) Alaska
+ 3 - (GMT-08:00) Pacific Time
+ 4 - (GMT-07:00) Arizona
+ 5 - (GMT-07:00) Montain Time
+ 6 - (GMT-06:00) Central Time
+ 7 - (GMT-05:00) Eastern Time
+ 8 - (GMT-05:00) Indiana (East)
+ 9 - (GMT-04:00) Atlantic Time (Canada)
+ 10- (GMT) Coordinated Universal Time
+ 11- (GMT) London
+ 12- (GMT+01:00) Berlin
+ 13- (GMT+01:00) Belgrade
+ 14- (GMT+01:00) Paris
+ 15- (GMT+02:00) Cairo
+ 16- (GMT+02:00) Helsinki
+ 17- (GMT+03:00) Baghdad
+ 18- (GMT+03:00) Moscow
+ 19- (GMT+03:30) Tehran
+ 20- (GMT+04:30) Kabul
+ 21- (GMT+05:00) Karachi
+ 22- (GMT+07:00) Bangkok
+ 23- (GMT+08:00) Shanghai
+ 24- (GMT+08:00) Taipei
+ 25- (GMT+09:00) Tokyo
+ 26- (GMT+09:00) Seoul
+ 27- (GMT+10:00) Sydney
+ 28- (GMT+10:00) Vladivostok"
+
+ ::= { ntp 6 }
+
+ commitNtpSettings OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(4..200))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "This command allows saving or clear the NTP and Tome Zone configuration.
+ If the save includes the change of time zone, the radio will automatically reboot
+ to take effect the newly selected time zone.
+ Option strings to be written are: save, clear, correspondingly saving changes to
+ configuration to the persistent storage or clearing unsaved changes."
+ ::= { ntp 1000 }
+
+ commitAdminSettings OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(4..200))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The Commit Administration settings command. Valid values: 'save', 'clear'.
+ Configuration changes via SNMP do not take effect until
+ 'save' (Commit) command is sent to this parameter.
+ 'clear' (Cancel) command is used to cancel configuration changes before commit operation.
+ In case of invalid configuration this parameter contains text description of the problem."
+ ::= { radioAdmin 1000 }
+
+ radioConfig OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION "The Radio Configuration Section."
+ ::= { productsMIBObjects 3 }
+
+ systemConfig OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION "This is the device specific configuration section."
+ ::= { radioConfig 1 }
+
+ commitSystemSettings OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The Commit System Configuration settings command. Valid values: 'save', 'clear'.
+ Configuration changes via SNMP do not take effect until
+ 'save' (Commit) command is sent to this parameter.
+ 'clear' (Cancel) command is used to cancel configuration changes before commit operation.
+ In case of invalid configuration this parameter contains text description of the problem."
+ ::= { systemConfig 1000 }
+
+ interface OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION "Radio Interfaces Configuration section."
+ ::= { radioConfig 2 }
+
+ te1 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION "T1,E1 interfaces Configuration section.
+ Section allows to configure T1/E1 ports on the radio if any."
+ ::= { interface 2 }
+
+ te1NumChannels OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "channels"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Number of T1 or E1 channels supported by the Radio."
+ ::= { te1 1 }
+
+ te1NumActiveChannels OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "channels"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Current number of channels available, based
+ on bandwitdh of the RF link and the license key."
+ ::= { te1 2 }
+
+ selectT1orE1 OBJECT-TYPE
+ SYNTAX INTEGER {
+ t1( 0 ),
+ e1( 1 )
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Select operation mode of T1/E1 interfaces. Either T1(0) or E1(1).
+ See Web, Configuration, Interface, T1/E1, Set To E1/T1 Mode button."
+ ::= { te1 3 }
+
+ te1Interfaces OBJECT-TYPE
+ SYNTAX SEQUENCE OF Te1InterfacesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Attributes for T1 or E1 ports."
+ ::= { te1 4 }
+
+ te1Interface OBJECT-TYPE
+ SYNTAX Te1InterfacesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the T1/E1 Attribute table."
+ INDEX {
+ te1Status, t1LBO, te1AIS, t1LineCode, te1LoopBackMode
+ }
+ ::= { te1Interfaces 1 }
+
+ Te1InterfacesEntry ::= SEQUENCE {
+ te1Status
+ Te1StatusT,
+ t1LBO
+ Te1LboT,
+ te1AIS
+ Te1StatusT,
+ t1LineCode
+ Te1LineCodeT,
+ te1LoopBackMode
+ Te1LoopBackModeT
+ }
+
+ te1Status OBJECT-TYPE
+ SYNTAX Te1StatusT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The T1/E1 status: enable(1)/disable(0).
+ Parameter allows to enable/disable each individual T1 channel.
+ See Web, Configuration, Interface, T1/E1, Status.
+ To make permanent, write save to commitTe1Settings after change."
+ ::= { te1Interface 1 }
+
+ t1LBO OBJECT-TYPE
+ SYNTAX Te1LboT
+ UNITS "feet"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The Line Build Out length range.
+ Valid values (ft): lbo0to133(0), lbo133to266(1), lbo266to399(2), lbo399to533(3), lbo533to655(4).
+ See Web, Configuration, Interface, T1/E1, LBO.
+ To make permanent, write save to commitTe1Settings after change."
+ ::= { te1Interface 2 }
+
+ te1AIS OBJECT-TYPE
+ SYNTAX Te1StatusT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The T1/E1 AIS enabled flag: enable(1)/disable(0).
+ If enabled, the radio places an AIS code on the output of the associated interface
+ if and when the link fails or when there is no E1 signal available from the far
+ end to provide the user at the local end.
+ See Web, Configuration, Interface, T1/E1, AIS.
+ To make permanent, write save to commitTe1Settings after change."
+ ::= { te1Interface 3 }
+
+ t1LineCode OBJECT-TYPE
+ SYNTAX Te1LineCodeT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The T1/E1 Line Code type: b8zs(0), ami(1).
+ See Web, Configuration, Interface, T1/E1, AIS, Line Code.
+ To make permanent, write save to commitTe1Settings after change."
+ ::= { te1Interface 4 }
+
+ te1LoopBackMode OBJECT-TYPE
+ SYNTAX Te1LoopBackModeT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The Loop Back Mode for a T1/E1 interface.
+ Valid values: disabled(0), ExternalLocal(1), ExternalRemote(2), Internal(3).
+ All loopback configurations control the loop at the Line Interface integrated circuit,
+ which is the device wired directly to the front panel ports.
+ See Web, Configuration, Interface, T1/E1, AIS, Loopback.
+ To make permanent, write save to commitTe1Settings after change."
+ ::= { te1Interface 5 }
+
+ commitTe1Settings OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(4..200))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The Commit TE1 Configuration settings command. Valid values: 'save', 'clear'.
+ Configuration changes to TE1 ports via SNMP do not take effect until
+ 'save' (Commit) command is sent to this parameter.
+ 'clear' (Cancel) command is used to cancel configuration changes before commit operation.
+ In case of invalid configuration this parameter contains text description of the problem."
+ ::= { te1 1000 }
+
+ fileManagement OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION "The File Management Section.
+ This section allows to initiate Upload/Download firmware/configuration/logs,
+ perform Firmware activation procedure."
+ ::= { radioConfig 3 }
+
+ currentFwFilename OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..100))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The file name of the currently running firmware.
+ See Web, Administration, File Management, File Activation, Current File."
+ ::= { fileManagement 1 }
+
+ alternateFwFilename OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..100))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The file name of the alternate firmware image.
+ See Web, Administration, File Management, File Activation, Alternative File."
+ ::= { fileManagement 2 }
+
+ swapFWimage OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..200))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Swap the firmware images and restart radio.
+ To perform swap operation 'swap' command needs to be sent to this parameter.
+ For ExtendAirG2 to perform revert to factory operation 'factory' command needs to be sent.
+ Radio will become unavailable for several minutes."
+ ::= { fileManagement 3 }
+
+ fileTransfer OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION "The File Transfer Section.
+ This section allows to initiate Upload/Download firmware/configuration/logs
+ over TFTP protocol."
+ ::= { fileManagement 4 }
+
+ factoryFwFilename OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..100))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The file name of the factory firmware image.
+ See Web, Administration, File Management, File Activation, Factory File."
+ ::= { fileManagement 5 }
+
+ tftpServerIp OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(7..15))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The TFTP Server IP address.
+ "
+ ::= { fileTransfer 1 }
+
+ uploadFilename OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..127))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The name of the file for upload operation.
+ For configuration file uploadFilename should be always 'config.xml'.
+ uploadFilename value should match the file name in TFTP server folder."
+ ::= { fileTransfer 2 }
+
+ transferType OBJECT-TYPE
+ SYNTAX FileTransferTypeT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "The file transfer type.
+ Valid values:
+ - uploadFirmware(0)
+ - uploadConfig(1)
+ - uploadRDD(2) (Valid only for TDD radios)
+ - downloadFirmware(3)
+ - downloadConfig(4)
+ - downloadMIBs(5)
+ - downloadEventLogs(6).
+ The actual operation starts via updating transferStart parameter value."
+ ::= { fileTransfer 3 }
+
+ transferStart OBJECT-TYPE
+ SYNTAX FileTransferStartT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "TransferStart parameter is used to initiate file transfer operation.
+ Send startTransfer(1) to this parameter."
+ ::= { fileTransfer 4 }
+
+ transferStatus OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..127))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The current file transfer status."
+ ::= { fileTransfer 5 }
+
+ radioMonitor OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION "Monitor Various components."
+ ::= { productsMIBObjects 4 }
+
+ -- gps OBJECT IDENTIFIER ::= { radioMonitor 1 }
+ -- satelliteInView OBJECT-TYPE ::= { gps 1 }
+ alarms OBJECT IDENTIFIER ::= { radioMonitor 2 }
+
+
+ almLocal OBJECT IDENTIFIER ::= { alarms 3 }
+ locSysAlarms OBJECT IDENTIFIER ::= { almLocal 1 }
+ locEthAlarms OBJECT IDENTIFIER ::= { almLocal 2 }
+ locTe1Alarms OBJECT IDENTIFIER ::= { almLocal 3 }
+ -- gigEAlarms OBJECT IDENTIFIER ::= { locAlarms 4 }
+ -- locDS3Alarms OBJECT IDENTIFIER ::= { locAlarms 5 }
+ -- locV35Alarms OBJECT IDENTIFIER ::= { locAlarms 6 }
+ -- locOduAlarms OBJECT IDENTIFIER ::= { locAlarms 7 }
+
+ locLinkState OBJECT-TYPE
+ SYNTAX AlarmLevelT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Link Status Alarm.
+ Possible values:
+ - almNORMAL(0) - Error-free connection (BER<10e-6)
+ - almMINOR(1) - Errorred connection (BER<10e-3)
+ - almMAJOR(2) - No link (BER>10e-3)
+ See Web, Monitor, Alarms, Link"
+ ::= { locSysAlarms 1 }
+
+ locTempAlarm OBJECT-TYPE
+ SYNTAX AlarmLevelT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Temperature Alarm state.
+ Possible values:
+ - almNORMAL(0) - Normal temprature range
+ - almMINOR(1) - Exceeding normal temprature range
+ See Web, Monitor, Alarms, Temperature"
+ ::= { locSysAlarms 2 }
+
+ locCurrentTemp OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "C"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Internal Temperature in Celsius."
+ ::= { locSysAlarms 3 }
+
+ locCurrentTempS OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Internal Temperature as a string. "
+ ::= { locSysAlarms 4 }
+
+ -- locCollocAlarm OBJECT-TYPE ::= { locSysAlarms 8 }
+ -- remCollocAlarm OBJECT-TYPE ::= { remSysAlarms 8 }
+
+ locLinkSecMismatch OBJECT-TYPE
+ SYNTAX AlarmLevelT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "This is link security mismatch alarm.
+ This alarm tells if the Link Security Key is matching or not.
+ Possible values:
+ - almNORMAL(0) - Link Secutiry keys match
+ - almMAJOR(2) - Link Secutiry keys do not match
+ "
+ ::= { locSysAlarms 9 }
+
+ locLinkStateV OBJECT-TYPE
+ SYNTAX AlarmLevelT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Vertical Link Status Alarm. -<g89><>"
+ ::= { locSysAlarms 15 }
+
+ locLinkStateH OBJECT-TYPE
+ SYNTAX AlarmLevelT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Horizontal Link Status Alarm. -<g89><>"
+ ::= { locSysAlarms 16 }
+
+-- T1/E1
+ locTe1LinkSummary OBJECT-TYPE
+ SYNTAX Led4ColorT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The T1/E1 Link Summary LED color. "
+ ::= { locTe1Alarms 1 }
+
+ locTE1Alarms OBJECT-TYPE
+ SYNTAX SEQUENCE OF Te1Alarms1Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The Local T1/E1 Interface Alarms."
+ ::= { locTe1Alarms 2 }
+
+ locTe1AlarmsEntry OBJECT-TYPE
+ SYNTAX Te1Alarms1Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "T1/E1 Alarms table Entry."
+ INDEX {
+ locTe1Alarm
+ }
+ ::= { locTE1Alarms 1 }
+
+ Te1Alarms1Entry ::= SEQUENCE {
+ locTe1Alarm
+ AlarmLevelT
+ }
+
+ locTe1Alarm OBJECT-TYPE
+ SYNTAX AlarmLevelT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Alarms state for the Local T1/E1 Channel.
+ Possible values:
+ - almNORMAL(0) - Enabled and connection present
+ - almMAJOR(2) - Enabled and no connection present
+ - almDisable(3) - Disabled and no connection present
+ - almNotAvailable(4) - T1/E1 channel is not available
+ See Web, Monitor, Alarms, T1/E1 Input"
+ ::= { locTe1AlarmsEntry 1 }
+
+-- end of te1 local alarms
+
+ almRemote OBJECT IDENTIFIER ::= { alarms 4 }
+ remSysAlarms OBJECT IDENTIFIER ::= { almRemote 1 }
+ remEthAlarms OBJECT IDENTIFIER ::= { almRemote 2 }
+ remTe1Alarms OBJECT IDENTIFIER ::= { almRemote 3 }
+
+ remLinkState OBJECT-TYPE
+ SYNTAX AlarmLevelT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Link Status Alarm for far end radio.
+ Possible values:
+ - almNORMAL(0) - Error-free connection (BER<10e-6)
+ - almMINOR(1) - Errorred connection (BER<10e-3)
+ - almMAJOR(2) - No link (BER>10e-3)
+ - almNotAvailable(4) - Telemetry is down
+ See Web, Monitor, Alarms, Link"
+ ::= { remSysAlarms 1 }
+
+ remTempAlarm OBJECT-TYPE
+ SYNTAX AlarmLevelT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Temperature Alarm state for far end radio.
+ Possible values:
+ - almNORMAL(0) - Normal temprature range
+ - almMINOR(1) - Exceeding normal temprature range
+ - almNotAvailable(4) - Telemetry is down
+ See Web, Monitor, Alarms, Temperature"
+ ::= { remSysAlarms 2 }
+
+ remCurrentTemp OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "C"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Internal Temperature in Celsius for far end radio. "
+ ::= { remSysAlarms 3 }
+
+ remCurrentTempS OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The internal Temperature as a string for far end radio. "
+ ::= { remSysAlarms 4 }
+
+-- remCollocAlarm OBJECT-TYPE ::= { remSysAlarms 8 }
+
+ remLinkSecMismatch OBJECT-TYPE
+ SYNTAX AlarmLevelT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "This is link security mismatch alarm.
+ This alarm tells if the Link Security Key is matching or not.
+ Possible values:
+ - almNORMAL(0) - Link Secutiry keys match
+ - almMAJOR(2) - Link Secutiry keys do not match
+ - almNotAvailable(4) - Telemetry is down
+ "
+ ::= { remSysAlarms 9 }
+
+ remLinkStateV OBJECT-TYPE
+ SYNTAX AlarmLevelT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Vertical Link Status Alarm. -<g89><>"
+ ::= { remSysAlarms 15 }
+
+ remLinkStateH OBJECT-TYPE
+ SYNTAX AlarmLevelT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Horizontal Link Status Alarm. -<g89><>"
+ ::= { remSysAlarms 16 }
+
+-- remote Te1 alarms
+ remTe1LinkSummary OBJECT-TYPE
+ SYNTAX Led4ColorT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The T1/E1 Link Summary LED color. "
+ ::= { remTe1Alarms 1 }
+
+ remTE1Alarms OBJECT-TYPE
+ SYNTAX SEQUENCE OF Te1AlarmsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "The Remotel T1/E1 Interface Alarms."
+ ::= { remTe1Alarms 2 }
+
+ remTe1AlarmsEntry OBJECT-TYPE
+ SYNTAX Te1AlarmsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "T1/E1 Alarms table Entry."
+ INDEX {
+ remTe1Alarm
+ }
+ ::= { remTE1Alarms 1 }
+
+ Te1AlarmsEntry ::= SEQUENCE {
+ remTe1Alarm
+ AlarmLevelT
+ }
+
+ remTe1Alarm OBJECT-TYPE
+ SYNTAX AlarmLevelT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Alarms state for the Local T1/E1 Channel of far end radio.
+ Possible values:
+ - almNORMAL(0) - Enabled and connection present
+ - almMAJOR(2) - Enabled and no connection present
+ - almDisable(3) - Disabled and no connection present
+ - almNotAvailable(4) - Telemetry is down or T1/E1 channel is not available
+ See Web, Monitor, Alarms, T1/E1 Input"
+ ::= { remTe1AlarmsEntry 1 }
+
+-- end remote Te1 alarms
+
+
+ performance OBJECT IDENTIFIER ::= { radioMonitor 3 }
+
+ perfLocal OBJECT IDENTIFIER ::= { performance 1 }
+
+ perfRemote OBJECT IDENTIFIER ::= { performance 2 }
+
+
+ locCurrentBER OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "BER * 1000000.0"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Curent Bit-Error Rate as scaled integer for local radio.
+ The BER multiplied by 1,000,000.
+ If the link is operating perfectly, this should indicate zero.
+ See Web, Monitor, Performance, Current BER"
+ ::= { perfLocal 1 }
+
+ locCurrentBERstr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Current Bit-Error Rate as a string. "
+ ::= { perfLocal 2 }
+
+ locCurrentRSL OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Current RSL is the measurement of the received signal level.
+ When the RSL falls below the threshold specification,
+ the link disconnects and will not reconnect until
+ the RSL is above the threshold specification.
+ See Web, Monitor, Performance, Current RSL"
+ ::= { perfLocal 3 }
+
+ locCurrentRSLstr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Current RSL as a string."
+ ::= { perfLocal 4 }
+
+ locErrorDuration OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Error Duration indicates the total number of seconds that occurred where
+ there was at least one bit error since the last time that
+ the radio statistics counter was reset.
+ See Web, Monitor, Performance, Errored Seconds"
+ ::= { perfLocal 5 }
+
+ locErrorDurationStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Error Duration as a formatted string."
+ ::= { perfLocal 6 }
+
+ locUnavailDuration OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Unavailable Duration keeps track of every second where the BER equals or exceeds 1x10-3,
+ as well as any seconds where there is a complete loss of radio communication.
+ See Web, Monitor, Performance, Unavailable Seconds"
+ ::= { perfLocal 7 }
+
+ locUnavailDurationStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Unavailable Duration as a formatted string."
+ ::= { perfLocal 8 }
+
+ locMinRSL OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Minimum RSL indicates the worst (lowest) received signal level
+ that occurred since the last counter reset.
+ See Web, Monitor, Performance, Minimum RSL"
+ ::= { perfLocal 9 }
+
+ locMinRSLstr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Minimum RSL value as a string."
+ ::= { perfLocal 10 }
+
+ locMinRSLtimestamp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Minimum RSL Timestamp indicates the date and time when the Minimum RSL occurred.
+ See Web, Monitor, Performance, Minimum RSL Timestamp"
+ ::= { perfLocal 11 }
+
+ locMaxRSL OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Maximum RSL indicates the best (highest) RSL
+ that occurred since the last counter reset.
+ See Web, Monitor, Performance, Maximum RSL"
+ ::= { perfLocal 12 }
+
+ locMaxRSLstr OBJECT-TYPE
+ SYNTAX DisplayString
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Maximum RSL level As string."
+ ::= { perfLocal 13 }
+
+ locSampleDuration OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Sample Duration indicates the amount of time passed since the last counter reset.
+ See Web, Monitor, Performance, Time Since Reset"
+ ::= { perfLocal 14 }
+
+ locSampleDurationStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Sample Duration value as a formatted string."
+ ::= { perfLocal 15 }
+
+ locEthPerfInterfaces OBJECT-TYPE
+ SYNTAX SEQUENCE OF LocEthPerfInterfacesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "Performance characteristics of local Ethernet interfaces"
+ ::= { perfLocal 16 }
+
+ locEthPerfInterfacesEntry OBJECT-TYPE
+ SYNTAX LocEthPerfInterfacesEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in the Performance characteristics of local Ethernet interfaces table"
+ INDEX {
+ locEthUtilizationIn,
+ locEthUtilizationOut,
+ locEthSpeed
+ }
+ ::= { locEthPerfInterfaces 1 }
+
+ LocEthPerfInterfacesEntry ::= SEQUENCE {
+ locEthUtilizationIn Integer32,
+ locEthUtilizationOut Integer32,
+ locEthSpeed DisplayString
+ }
+
+ locEthUtilizationIn OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Inbound ethernet utilization (%).
+ See Web, Analysis, Ethernet Utilization."
+ ::= { locEthPerfInterfacesEntry 1 }
+
+ locEthUtilizationOut OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Outbound ethernet utilization (%).
+ See Web, Analysis, Ethernet Utilization."
+ ::= { locEthPerfInterfacesEntry 2 }
+
+ locEthSpeed OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Current Ethernet Speed.
+ See Web, Monitor, Ethernet Performance."
+ ::= { locEthPerfInterfacesEntry 3 }
+
+ locEthUtilizationWatermarkEnabled OBJECT-TYPE
+ SYNTAX ExaltEnableT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Ethernet utilization watermark enable(1)/disable(0).
+ See Web, Analysis, Ethernet Utilization, Ethernet Utilization Watermark."
+ ::= { perfLocal 17 }
+
+ locEthUtilizationWatermark OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Ethernet utilization watermark level (%).
+ See Web, Analysis, Ethernet Utilization, Watermark level."
+ ::= { perfLocal 18 }
+
+ locEthUtilizationWatermarkTrapEnabled OBJECT-TYPE
+ SYNTAX ExaltEnableT
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Ethernet utilization watermark trap enable(1)/disable(0).
+ The watermark trap function allows administrators to receive an SNMP trap
+ when watermark conditions are exceeded.
+ See Web, Analysis, Ethernet Utilization, Enable Ethernet Utilization Trap."
+ ::= { perfLocal 19 }
+
+ locEthUtilizationWatermarkTrapDuration OBJECT-TYPE
+ SYNTAX Integer32 (0..1440)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Ethernet utilization trap limit in minutes/day (0-1440 minutes).
+ See Web, Analysis, Ethernet Utilization, Send trap if watermark hit duration exceeds."
+ ::= { perfLocal 20 }
+
+ locMaximumTxModulation OBJECT-TYPE
+ SYNTAX AcmModulationT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The highest/maximum Tx modulation when ACM is enabled since the last counter reset.
+ See Web, Monitor, Performance, Tx modulation."
+ ::= { perfLocal 100 }
+
+ locActiveTxModulation OBJECT-TYPE
+ SYNTAX AcmModulationT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The active Tx modulation when ACM is enabled.
+ See Web, Monitor, Performance, Tx modulation."
+ ::= { perfLocal 101 }
+
+ locMinimumTxModulation OBJECT-TYPE
+ SYNTAX AcmModulationT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The lowest/minimum Tx modulation when ACM is enabled since the last counter reset.
+ See Web, Monitor, Performance, Tx modulation."
+ ::= { perfLocal 102 }
+
+
+ locMaximumRxModulation OBJECT-TYPE
+ SYNTAX AcmModulationT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The highest/maximum Rx modulation when ACM is enabled since the last counter reset.
+ See Web, Monitor, Performance, Rx modulation."
+ ::= { perfLocal 103 }
+
+
+ locActiveRxModulation OBJECT-TYPE
+ SYNTAX AcmModulationT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The active Rx modulation when ACM is enabled.
+ See Web, Monitor, Performance, Rx modulation."
+ ::= { perfLocal 104 }
+
+
+ locMinimumRxModulation OBJECT-TYPE
+ SYNTAX AcmModulationT
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The lowest/minimum Rx modulation when ACM is enabled since the last counter reset.
+ See Web, Monitor, Performance, Rx modulation."
+ ::= { perfLocal 105 }
+
+
+ --
+ -- ACM Tx/Rx Ethernet throughtput
+ --
+
+ locMaximumTxEthernetThroughput OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The highest/maximum Tx Ethernet throughput in Mbps when ACM is enabled
+ since the last counter reset.
+ See Web, Monitor, Performance, Tx Ethernet Throughput."
+ ::= { perfLocal 106 }
+
+
+ locActiveTxEthernetThroughput OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The active Tx Ethernet throughput in Mbps when ACM is enabled.
+ See Web, Monitor, Performance, Tx Ethernet Throughput."
+ ::= { perfLocal 107 }
+
+
+ locMinimumTxEthernetThroughput OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The lowest/minimum Tx Ethernet throughput in Mbps when ACM is enabled
+ since the last counter reset.
+ See Web, Monitor, Performance, Tx Ethernet Throughput."
+ ::= { perfLocal 108 }
+
+
+ locMaximumRxEthernetThroughput OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The highest/maximum Rx Ethernet throughput in Mbps when ACM is enabled
+ since the last counter reset.
+ See Web, Monitor, Performance, Rx Ethernet Throughput."
+ ::= { perfLocal 109 }
+
+
+ locActiveRxEthernetThroughput OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The active Rx Ethernet throughput in Mbps when ACM is enabled.
+ See Web, Monitor, Performance, Rx Ethernet Throughput."
+ ::= { perfLocal 110 }
+
+
+ locMinimumRxEthernetThroughput OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The lowest/minimum Rx Ethernet throughput in Mbps when ACM is enabled
+ since the last counter reset.
+ See Web, Monitor, Performance, Rx Ethernet Throughput."
+ ::= { perfLocal 111 }
+
+ locResetStats OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Write 'reset' to locResetStats to clear the Performance statistics."
+ ::= { perfLocal 1000 }
+
+
+ remCurrentBER OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "BER * 1000000.0"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Curent Bit-Error Rate as scaled integer for far end radio.
+ The BER multiplied by 1,000,000.
+ If the link is operating perfectly, this should indicate zero.
+ See Web, Monitor, Performance, Current BER"
+ ::= { perfRemote 1 }
+
+ remCurrentBERstr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Current Bit-Error Rate as a string. Far end radio"
+ ::= { perfRemote 2 }
+
+ remCurrentRSL OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Current RSL is the measurement of the received signal level.
+ When the RSL falls below the threshold specification,
+ the link disconnects and will not reconnect until
+ the RSL is above the threshold specification.
+ See Web, Monitor, Performance, Current RSL"
+ ::= { perfRemote 3 }
+
+ remCurrentRSLstr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Current RSL as a string."
+ ::= { perfRemote 4 }
+
+ remErrorDuration OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Error Duration indicates the total number of seconds that occurred where
+ there was at least one bit error since the last time that
+ the radio statistics counter was reset.
+ See Web, Monitor, Performance, Errored Seconds, Remote column."
+ ::= { perfRemote 5 }
+
+ remErrorDurationStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Error Duration as a formatted string. Far end radio."
+ ::= { perfRemote 6 }
+
+ remUnavailDuration OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Unavailable Duration keeps track of every second where the BER equals or exceeds 1x10-3,
+ as well as any seconds where there is a complete loss of radio communication.
+ See Web, Monitor, Performance, Unavailable Seconds"
+ ::= { perfRemote 7 }
+
+ remUnavailDurationStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Unavailable Duration as a formatted string. Far end radio."
+ ::= { perfRemote 8 }
+
+ remMinRSL OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Minimum RSL indicates the worst (lowest) received signal level
+ that occurred since the last counter reset.
+ See Web, Monitor, Performance, Minimum RSL, Remote column."
+ ::= { perfRemote 9 }
+
+ remMinRSLstr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Minimum RSL value as a string. Far end radio."
+ ::= { perfRemote 10 }
+
+ remMinRSLtimestamp OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Minimum RSL Timestamp indicates the date and time when the Minimum RSL occurred.
+ See Web, Monitor, Performance, Minimum RSL Timestamp, Remote column."
+ ::= { perfRemote 11 }
+
+ remMaxRSL OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Maximum RSL indicates the best (highest) RSL
+ that occurred since the last counter reset.
+ See Web, Monitor, Performance, Maximum RSL, Remote column."
+ ::= { perfRemote 12 }
+
+ remMaxRSLstr OBJECT-TYPE
+ SYNTAX DisplayString
+ UNITS "dBm"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Maximum RSL level As string. Far end radio."
+ ::= { perfRemote 13 }
+
+ remSampleDuration OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Sample Duration indicates the amount of time passed since the last counter reset.
+ See Web, Monitor, Performance, Time Since Reset, Remote column."
+ ::= { perfRemote 14 }
+
+ remSampleDurationStr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Sample Duration value as a formatted string. Far end radio."
+ ::= { perfRemote 15 }
+
+ remResetStats OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Write 'reset' to remResetStats to clear the Performance statistics."
+ ::= { perfRemote 1000 }
+
+ userThroughput OBJECT IDENTIFIER ::= { radioMonitor 5 }
+
+ aggregateUserThroughput OBJECT-TYPE
+ SYNTAX DisplayString
+ UNITS "MBit/s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Aggregated User Throughput.
+ For FDD radios this parameter is always equal to fullDuplexEthernetThroughput."
+ ::= { userThroughput 1 }
+
+ inboundEthernetThroughput OBJECT-TYPE
+ SYNTAX DisplayString
+ UNITS "MBit/s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Inbound Ethernet Throughput.
+ For FDD radios this parameter is always N/A."
+ ::= { userThroughput 2 }
+
+ outboundEthernetThroughput OBJECT-TYPE
+ SYNTAX DisplayString
+ UNITS "MBit/s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "Outbound Ethernet Throughput.
+ For FDD radios this parameter is always N/A."
+ ::= { userThroughput 3 }
+
+ fullDuplexEthernetThroughput OBJECT-TYPE
+ SYNTAX DisplayString
+ UNITS "MBit/s"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "The Full Duplex Ethernet Throughput is determined by
+ the combination of settings for Mode and Bandwidth.
+ See Web, Monitor, User Throughput, Full Duplex Ethernet Throughput."
+ ::= { userThroughput 4 }
+
+ radioReboot OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..100))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION "Reboot the radio device.
+ Send 'reboot' to radioReboot parameter to reboot the radio device."
+ ::= { productsMIBObjects 1000 }
+
+ productsMIBConformance OBJECT IDENTIFIER ::= { productsMIB 3 }
+
+ productsMIBCompliances OBJECT IDENTIFIER ::= { productsMIBConformance 1 }
+
+ productsMIBGroups OBJECT IDENTIFIER ::= { productsMIBConformance 2 }
+
+ productsAllObjects OBJECT-GROUP
+ OBJECTS {
+ modelName,
+ partNumber,
+ serialNumber,
+ interfaceType,
+ firmwareVersion,
+ bootVersion,
+ rfFreqBand,
+ sysDate,
+ sysTime,
+ rnLocal,
+ rnRemote,
+ linkName,
+ linkSecKey,
+ adminPassword,
+ userPassword,
+ ipLocal,
+ ipRemote,
+ subnetMask,
+ ipAddressNetmask,
+ defaultGateway,
+ commitAdminSettings,
+ te1NumChannels,
+ te1NumActiveChannels,
+ selectT1orE1,
+ commitTe1Settings,
+ currentFwFilename,
+ alternateFwFilename,
+ swapFWimage,
+ locLinkState,
+ locLinkStateV,
+ locLinkStateH,
+ locTe1LinkSummary,
+ locTempAlarm,
+ locCurrentTemp,
+ locCurrentTempS,
+ locLinkSecMismatch,
+ remLinkState,
+ remLinkStateV,
+ remLinkStateH,
+ remTe1LinkSummary,
+ remTempAlarm,
+ remCurrentTemp,
+ remCurrentTempS,
+ remLinkSecMismatch,
+ locCurrentBER,
+ locCurrentBERstr,
+ locCurrentRSL,
+ locCurrentRSLstr,
+ locErrorDuration,
+ locErrorDurationStr,
+ locUnavailDuration,
+ locUnavailDurationStr,
+ locMinRSL,
+ locMinRSLstr,
+ locMinRSLtimestamp,
+ locMaxRSL,
+ locMaxRSLstr,
+ locSampleDuration,
+ locSampleDurationStr,
+ locResetStats,
+ remCurrentBER,
+ remCurrentBERstr,
+ remCurrentRSL,
+ remCurrentRSLstr,
+ remErrorDuration,
+ remErrorDurationStr,
+ remUnavailDuration,
+ remUnavailDurationStr,
+ remMinRSL,
+ remMinRSLstr,
+ remMinRSLtimestamp,
+ remMaxRSL,
+ remMaxRSLstr,
+ remSampleDuration,
+ remSampleDurationStr,
+ remResetStats,
+ radioReboot,
+ te1Status,
+ t1LBO,
+ te1AIS,
+ t1LineCode,
+ te1LoopBackMode,
+ locTe1Alarm,
+ remTe1Alarm,
+ aesEnable,
+ licKey,
+ aggregateUserThroughput,
+ inboundEthernetThroughput,
+ outboundEthernetThroughput,
+ fullDuplexEthernetThroughput,
+ locEthUtilizationIn,
+ locEthUtilizationOut,
+ locEthUtilizationWatermarkEnabled,
+ locEthUtilizationWatermark,
+ locEthUtilizationWatermarkTrapEnabled,
+ locEthUtilizationWatermarkTrapDuration
+ }
+ STATUS current
+ DESCRIPTION "This automatically created object group contains
+ all those objects that do not belong to any other
+ OBJECT-GROUP"
+ ::= { productsMIBGroups 1 }
+
+END
+