diff options
Diffstat (limited to 'MIBS/extreme/EXTREME-POE-MIB')
| -rw-r--r-- | MIBS/extreme/EXTREME-POE-MIB | 433 |
1 files changed, 433 insertions, 0 deletions
diff --git a/MIBS/extreme/EXTREME-POE-MIB b/MIBS/extreme/EXTREME-POE-MIB new file mode 100644 index 0000000..6268128 --- /dev/null +++ b/MIBS/extreme/EXTREME-POE-MIB @@ -0,0 +1,433 @@ + +-- ============================================================================ +-- +-- Extreme Services +-- + +EXTREME-POE-MIB DEFINITIONS ::= BEGIN + IMPORTS + MODULE-IDENTITY FROM SNMPv2-SMI + OBJECT-TYPE FROM SNMPv2-SMI + NOTIFICATION-TYPE FROM SNMPv2-SMI + Integer32 FROM SNMPv2-SMI + Gauge32 FROM SNMPv2-SMI + Counter32 FROM SNMPv2-SMI + TruthValue FROM SNMPv2-TC + extremeAgent FROM EXTREME-BASE-MIB + extremeV2Traps FROM EXTREME-BASE-MIB + pethMainPseGroupIndex, + pethPsePortGroupIndex, + pethPsePortIndex FROM POWER-ETHERNET-MIB; + + + + extremePoE MODULE-IDENTITY + LAST-UPDATED "0007240000Z" + ORGANIZATION "Extreme Networks, Inc." + CONTACT-INFO "www.extremenetworks.com" + DESCRIPTION "Extreme Power over Ethernet MIB objects" + ::= { extremeAgent 27 } + + extremePethMain OBJECT IDENTIFIER ::= {extremePoE 1} + extremePethPort OBJECT IDENTIFIER ::= {extremePoE 2} +-- powerEthernetMIB OBJECT IDENTIFIER ::= {extremePoE 3} + extremePethSystem OBJECT IDENTIFIER ::= {extremePoE 4} +-- extremePethTraps OBJECT IDENTIFIER ::= {extremeV2Traps 12} + + +-- extremePethSystem +extremePethSystemAdminEnable OBJECT-TYPE + SYNTAX INTEGER { + enable(1), + disable(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether inline power is provided by the system." + DEFVAL { enable } + ::= { extremePethSystem 1 } + +extremePethSystemDisconnectPrecedence OBJECT-TYPE + SYNTAX INTEGER { + lowestPriority(1), + denyPort(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls the disconnect function of power management. + When the power drain exceeds the available power budget, + due to a rise in power consumption after power is allocated + to the ports, the PoE controller disconnects one of the ports + to prevent overload on the power supply. There are two controls: + Lowest-priority: next port connected causes a shutdown of the + lowest priority port. + Deny-port: next port is denied power, regardless of priority." + DEFVAL { denyPort } + ::= { extremePethSystem 2 } + +extremePethSystemUsageThreshold OBJECT-TYPE + SYNTAX Integer32 (1..99) + UNITS "%" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The usage threshold expressed in percents for + comparing the measured power and initiating + an alarm if the threshold is exceeded." + ::= { extremePethSystem 3 } + +extremePethSystemPowerSupplyMode OBJECT-TYPE + SYNTAX INTEGER { + redundant(1), + loadSharing(2), + notApplicable(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether the power supply operate in + redundant or load-sharing mode. Systems which do not + provide redundant or load-sharing operations will return + an error on setting, and notApplicable on read." + ::= { extremePethSystem 4 } + +extremePethSystemLegacyEnable OBJECT-TYPE + SYNTAX INTEGER { + enable(1), + disable(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls whether legacy is supported by the system. This is only supported on + S300-24 stackables currently." + DEFVAL { disable } + ::= { extremePethSystem 5 } + + + +-- Per Slot Table +extremePethPseSlotTable OBJECT-TYPE + SYNTAX SEQUENCE OF ExtremePethPseSlotEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of objects that provides power management capabilities per slot." + ::= { extremePethMain 2 } + +extremePethPseSlotEntry OBJECT-TYPE + SYNTAX ExtremePethPseSlotEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A set of objects that display and control the power characteristics of a slot." + INDEX { extremePethSlotNumber } + ::= { extremePethPseSlotTable 1 } + +ExtremePethPseSlotEntry ::= SEQUENCE { + extremePethSlotNumber Integer32, + extremePethSlotPowerLimit Integer32, + extremePethSlotConsumptionPower Gauge32, + extremePethSlotClearConnectHistory INTEGER, + extremePethSlotReservedConsumptionPower Gauge32, + extremePethSlotCommonConsumptionPower Gauge32, + extremePethSlotAdminEnable INTEGER, + extremePethSlotPoeStatus INTEGER, + extremePethSlotPoeResetSystem INTEGER, + extremePethSlotMaxAvailPower Gauge32, + extremePethSlotMaxCapacity Gauge32, + extremePethSlotBackupPSU INTEGER, + extremePethSlotPSUActive INTEGER, + extremePethSlotMeasuredPower Gauge32, + extremePethSlotMainPseIndex Integer32 +} + +extremePethSlotNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Slot number. This is the same as the Group Index" + ::= { extremePethPseSlotEntry 1 } + +extremePethSlotPowerLimit OBJECT-TYPE + SYNTAX Integer32 + UNITS "watts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The configured maximum amount of inline power available to + slot. The operational power available to the slot is based + upon other operational and configuration parameters, such as + the power-supply mode and status. This number is provided by + the object extremePethSlotMaxAvailPower. extremePethSlotPowerLimit + may be greater than extremePethSlotMaxAvailPower, however, cannot + exceed the maximum slot capacity, provided by extremePethSlotMaxCapacity" + ::= { extremePethPseSlotEntry 2 } + +extremePethSlotConsumptionPower OBJECT-TYPE + SYNTAX Gauge32 + UNITS "watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The amount of power allocated to PoE devices on the slot expressed in mWatts. + The amount of power allocated to a PoE device is based upon the PoE device + class and/or the port's extremePethPortViolationPrecedence setting. For + example, in the default configuration of extremePethPortViolationPrecedence + set to maxAdvertisedOperator(3), and the extremePethPortOperatorLimit set to + 15400, a PoE device is allocated 15.4 watts." + ::= { extremePethPseSlotEntry 3 } + +extremePethSlotClearConnectHistory OBJECT-TYPE + SYNTAX INTEGER { set(1), + clear(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Clears the port connection history of the specified slot. + Reading the value always reurns clear(2)." + ::= { extremePethPseSlotEntry 4 } + +extremePethSlotReservedConsumptionPower OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Milliwatts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The amount of reserved power consumed on the slot expressed in Milliwatts." + ::= { extremePethPseSlotEntry 5 } + +extremePethSlotCommonConsumptionPower OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Milliwatts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The amount of common power allocated on the slot expressed in Milliwatts. + This value is computed by the formula: + extremePethSlotConsumptionPower - extremePethSlotReservedConsumptionPower." + ::= { extremePethPseSlotEntry 6 } + +extremePethSlotAdminEnable OBJECT-TYPE + SYNTAX INTEGER { + enable(1), + disable(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Controls whether inline power is provided by the slot." + DEFVAL { enable } + ::= { extremePethPseSlotEntry 7 } + +extremePethSlotPoeStatus OBJECT-TYPE + SYNTAX INTEGER { + initializing(1), + operational(2), + downloadFail(3), + calibrationRequired(4), + invalidFirmware(5), + mismatchVersion(6), + updating(7), + invalidDevice(8), + notOperational(9), + other(10) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Describes the status of the PoE system on the slot. + initializing - PoE controller is under initialization, + operational - PoE controller is operational and is ready or + providing power, + downloadFail - PoE controller required update and the update + failed, PoE reset is required to re-update, + calibrationRequired - PoE contoller is operational, however + calibration is required to provide power, + invalidFirmware - PoE controller contains invalid firmware, + mismatchVersion - PoE controller update completed, however + version mismatches expected, reboot, + updating - PoE controller is being updated, + invalidDevice - PoE controller detected an invalid/bad PoE + device. + notOperational - PoE controller is not yet operational + other - PoE controller is in undefined stats." + ::= { extremePethPseSlotEntry 8 } + +extremePethSlotPoeResetSystem OBJECT-TYPE + SYNTAX INTEGER { set(1), clear(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Resets the PoE system on the slot. Reading returns clear(2)" + ::= { extremePethPseSlotEntry 9 } + +extremePethSlotMaxAvailPower OBJECT-TYPE + SYNTAX Gauge32 + UNITS "watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum power available to the slot expressed in Watts. + The value depends on various configuration parameters and + power-supply modes and status." + ::= { extremePethPseSlotEntry 10 } + +extremePethSlotMaxCapacity OBJECT-TYPE + SYNTAX Gauge32 + UNITS "watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum capacity of the slot expressed in Watts. This + provides the hardware limitation of the slot. Actual + amount of power is dependant on system status. The + object extremePethSlotPowerLimit must not be greater than + this amount." + ::= { extremePethPseSlotEntry 11 } + +extremePethSlotBackupPSU OBJECT-TYPE + SYNTAX INTEGER { + none(1), + internal(2), + external(3), + notApplicable(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Controls the backup power supply for inline power for the slot. + A system which does not allow the backup PSU to be + configured will return an error upon setting." + ::= { extremePethPseSlotEntry 12 } + +extremePethSlotPSUActive OBJECT-TYPE + SYNTAX INTEGER { + none(1), + internal(2), + external(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Inline Power supply status indication for the slot. Indicates which PSU + is currently active. In the case of a failover a none indication can + occur until one of the PSU has finished powering up." + ::= { extremePethPseSlotEntry 13 } + +extremePethSlotMeasuredPower OBJECT-TYPE + SYNTAX Gauge32 + UNITS "milliwatts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The measured amount of power for all PoE device on the + slot." + ::= { extremePethPseSlotEntry 14 } + +extremePethSlotMainPseIndex OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index into the PethMainPseTable. Provides the + mapping of the slot identifier to pethMainPseGroupIndex." + ::= { extremePethPseSlotEntry 15 } + + +extremePethPsePortTable OBJECT-TYPE + SYNTAX SEQUENCE OF ExtremePethPsePortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of objects that extends the standard pethPsePortTable." + ::= { extremePethPort 1 } + +extremePethPsePortEntry OBJECT-TYPE + SYNTAX ExtremePethPsePortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A set of objects that display and control the power characteristics + of a powerEthernet PSE port. This table extends the standard pethPsePortTable." + INDEX { pethPsePortGroupIndex, pethPsePortIndex } + ::= { extremePethPsePortTable 1 } + +ExtremePethPsePortEntry ::= SEQUENCE { + extremePethPortOperatorLimit Integer32, + extremePethPortReservedBudget Integer32, + extremePethPortViolationPrecedence INTEGER, + extremePethPortClearFault INTEGER, + extremePethPortResetPower INTEGER, + extremePethPortMeasuredPower Gauge32 +} + +extremePethPortOperatorLimit OBJECT-TYPE + SYNTAX Integer32 (3000..20000) + UNITS "Milliwatts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls individual port maximum power level." + DEFVAL { 15400 } + ::= { extremePethPsePortEntry 1 } + +extremePethPortReservedBudget OBJECT-TYPE + SYNTAX Integer32 (0..20000) + UNITS "Milliwatts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Controls individual port maximum power level. Value is 0 or + in the range of 3000..20000" + DEFVAL { 0 } + ::= { extremePethPsePortEntry 2 } + +extremePethPortViolationPrecedence OBJECT-TYPE + SYNTAX INTEGER {advertisedClass(1), + operatorLimit(2), + maxAdvertisedOperator(3), + none(4) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Sets the violation precedence for the specified ports. A value of + advertised-class will remove/deny power in the case an 802.3af compliant + PD consumes power beyond its advertised class limit. A value of + operator-limit will remove/deny power should the PD consume power + beyond the configured operator-limit. A value of max-class-operator will + remove/deny power if the PD consumes power beyond the maximum of the + detected class limit and the operator-limit. A value of none will + remove/deny power in case the PD device exceeds the maximum allowable + wattage according to regulatory maximum of 20 W. Default is + max-class-operator which allows operation of both 802.3af compliant and + legacy PDs." + ::= { extremePethPsePortEntry 3 } + +extremePethPortClearFault OBJECT-TYPE + SYNTAX INTEGER { set(1), clear(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Clears the fault condition. Reading always returns clear(2)." + ::= { extremePethPsePortEntry 4 } + +extremePethPortResetPower OBJECT-TYPE + SYNTAX INTEGER { set(1), clear(2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Resets the power on the port. Reading always returns clear(2)" + ::= { extremePethPsePortEntry 5 } + +extremePethPortMeasuredPower OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Milliwatts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The amount of power consumed on the port expressed in Milliwatts." + ::= { extremePethPsePortEntry 6 } + +END |