summaryrefslogtreecommitdiff
path: root/MIBS/gepower/NE843-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/gepower/NE843-MIB')
-rw-r--r--MIBS/gepower/NE843-MIB14454
1 files changed, 14454 insertions, 0 deletions
diff --git a/MIBS/gepower/NE843-MIB b/MIBS/gepower/NE843-MIB
new file mode 100644
index 0000000..28ae1cb
--- /dev/null
+++ b/MIBS/gepower/NE843-MIB
@@ -0,0 +1,14454 @@
+NE843-MIB DEFINITIONS ::= BEGIN
+IMPORTS
+ enterprises, MODULE-IDENTITY, OBJECT-TYPE, Integer32, NOTIFICATION-TYPE
+ FROM SNMPv2-SMI
+ DisplayString
+ FROM SNMPv2-TC;
+
+teps OBJECT IDENTIFIER ::= { enterprises 10520 }
+controllermibs OBJECT IDENTIFIER ::= { teps 2 }
+release OBJECT IDENTIFIER ::= { controllermibs 1 }
+prototypes OBJECT IDENTIFIER ::= { controllermibs 2 }
+
+ne843 MODULE-IDENTITY
+ LAST-UPDATED "201601121648Z"
+ ORGANIZATION "GE Power Electronics, Inc."
+ CONTACT-INFO "Chris Brooke - Power Systems
+
+ Phone: +1 972 244 9288
+
+ Postal: Power Systems
+ 601 Shiloh Road
+ Plano, TX 75074
+ USA"
+
+ DESCRIPTION "MIB for NE843 Power System."
+
+ REVISION "201601121648Z"
+ DESCRIPTION "Added DPN, and DBY"
+
+ REVISION "201510301950Z"
+ DESCRIPTION "Added PIC, PCM, PVM, PTM and PCS. Add integer representation for some variables"
+
+ REVISION "201503272138Z"
+ DESCRIPTION "Added 3-Phase rectifier voltages and currents"
+
+ REVISION "201412152301Z"
+ DESCRIPTION "Added Bulk Data Report"
+
+ REVISION "201410222033Z"
+ DESCRIPTION "Added IPV6 Parameters"
+
+ REVISION "201406101441Z"
+ DESCRIPTION "Added Trap/Alarm, change name of inverter plant"
+
+ REVISION "201405211844Z"
+ DESCRIPTION "Added High Temperature Load Disconnect"
+
+ REVISION "201403181952Z"
+ DESCRIPTION "Added Inverters, ECO Priority, and ORing Fet Parameters"
+
+ REVISION "201210032143Z"
+ DESCRIPTION "Add more objects and updates from CP841 and Millennium 2"
+
+
+ REVISION "201006281408Z"
+ DESCRIPTION "Add more objects to traps"
+
+ REVISION "200906181832Z"
+ DESCRIPTION "Switch to unique object names"
+
+ REVISION "200905141624Z"
+ DESCRIPTION "Add updates from CP841 and IEPSO"
+
+ REVISION "200704031635Z"
+ DESCRIPTION "Initial release"
+
+ ::= { release 3 }
+
+--
+-- object ne843Dc1
+--
+
+ne843Dc1 OBJECT IDENTIFIER ::= { ne843 1 }
+
+ne843Dc1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Dc1 1 }
+
+ne843Dc1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Dc1 2 }
+
+ne843Dc1Typ OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Type"
+ ::= { ne843Dc1 3 }
+
+ne843Dc1Vdc OBJECT-TYPE
+SYNTAX Integer32
+UNITS "mV"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Voltage (mV)"
+ ::= { ne843Dc1 4 }
+
+ne843Dc1Adc OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Current (Amps)"
+ ::= { ne843Dc1 5 }
+
+ne843Dc1Cap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Total Installed Rectifier Capacity (Amps)"
+ ::= { ne843Dc1 6 }
+
+ne843Dc1Olcap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Total On-line Rectifier Capacity (Amps)"
+ ::= { ne843Dc1 7 }
+
+ne843Dc1Trd OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Total Rectifier Drain (Amps)"
+ ::= { ne843Dc1 8 }
+
+ne843Dc1Sht OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Centralized Plant Shunt Type
+Values:
+NONE,
+BATTERY,
+LOAD
+"
+ ::= { ne843Dc1 9 }
+
+ne843Dc1Sha OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Centralized Plant Shunt Size (Amps)"
+ ::= { ne843Dc1 10 }
+
+ne843Dc1Stt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"State
+Values:
+FLOAT,
+BOOST
+"
+ ::= { ne843Dc1 11 }
+
+ne843Dc1Bod OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Battery On Discharge"
+ ::= { ne843Dc1 12 }
+
+ne843Dc1Rss OBJECT-TYPE
+SYNTAX INTEGER {
+off(0),
+on(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Rectifier Restart
+Values:
+off(0),
+on(1)
+"
+ ::= { ne843Dc1 13 }
+
+ne843Dc1Rsq OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Rectifier Sequencing
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Dc1 14 }
+
+ne843Dc1Ron OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"External Standby"
+ ::= { ne843Dc1 15 }
+
+ne843Dc1Rot OBJECT-TYPE
+SYNTAX Integer32(20000..25000|40000..50000)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"All Rectifier On Threshold (mV)"
+ ::= { ne843Dc1 16 }
+
+ne843Dc1Nst OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Strings"
+ ::= { ne843Dc1 17 }
+
+ne843Dc1Cps OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Cells per String"
+ ::= { ne843Dc1 18 }
+
+ne843Dc1Bty OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Battery Type"
+ ::= { ne843Dc1 19 }
+
+ne843Dc1Isd OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Imminent Shutdown Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Dc1 20 }
+
+ne843Dc1Rtm OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Reserve Time"
+ ::= { ne843Dc1 21 }
+
+ne843Dc1Scap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"String Capacity (Amps)"
+ ::= { ne843Dc1 22 }
+
+ne843Dc1Mls OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"All Shunts Monitored
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Dc1 23 }
+
+ne843Dc1Amj OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Auxiliary Fuse Major
+Value:
+Alarm report from AMJ1
+"
+ ::= { ne843Dc1 24 }
+
+ne843Dc1Vsf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Sense/Control Fuse
+Value:
+Alarm report from VSF1
+"
+ ::= { ne843Dc1 25 }
+
+ne843Dc1Osa OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Open String
+Value:
+Alarm report from OSA1
+"
+ ::= { ne843Dc1 26 }
+
+ne843Dc1Zid OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ID Not Configured
+Value:
+Alarm report from ZID1
+"
+ ::= { ne843Dc1 27 }
+
+ne843Dc1Tpa OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Thermal Probe Alarm
+Value:
+Alarm report from TPA1
+"
+ ::= { ne843Dc1 28 }
+
+ne843Dc1Vmf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Voltage Module Fail
+Value:
+Alarm report from VMF1
+"
+ ::= { ne843Dc1 29 }
+
+ne843Dc1Cma OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Minor Communication Failure
+Value:
+Alarm report from CMA1
+"
+ ::= { ne843Dc1 30 }
+
+ne843Dc1Mcm OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Major Communication Failure
+Value:
+Alarm report from MCM1
+"
+ ::= { ne843Dc1 31 }
+
+ne843Dc1Epo OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Emergency Power Off
+Value:
+Alarm report from EPO1
+"
+ ::= { ne843Dc1 32 }
+
+ne843Dc1Icr OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Incompatible Rectifier
+Value:
+Alarm report from ICR1
+"
+ ::= { ne843Dc1 33 }
+
+ne843Dc1Rfa OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Rectifier Fail
+Value:
+Alarm report from RFA1
+"
+ ::= { ne843Dc1 34 }
+
+ne843Dc1Acf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"AC Fail
+Value:
+Alarm report from ACF1
+"
+ ::= { ne843Dc1 35 }
+
+ne843Dc1Man OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Manual Off
+Value:
+Alarm report from MAN1
+"
+ ::= { ne843Dc1 36 }
+
+ne843Dc1Did OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ID Conflict
+Value:
+Alarm report from DID1
+"
+ ::= { ne843Dc1 37 }
+
+ne843Dc1Clm OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Rectifier Current Limit
+Value:
+Alarm report from CLM1
+"
+ ::= { ne843Dc1 38 }
+
+ne843Dc1Rfn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Rectifier Fan Failure
+Value:
+Alarm report from RFN1
+"
+ ::= { ne843Dc1 39 }
+
+ne843Dc1Vla OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Very Low Voltage
+Value:
+Alarm report from VLA1
+"
+ ::= { ne843Dc1 40 }
+
+ne843Dc1Mfa OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Multiple Rectifier Fail
+Value:
+Alarm report from MFA1
+"
+ ::= { ne843Dc1 41 }
+
+ne843Dc1Rtl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Reserve Time Low
+Value:
+Alarm report from RTL1
+"
+ ::= { ne843Dc1 42 }
+
+ne843Dc1Rrtl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Real-time Reserve Time Low
+Value:
+Alarm report from RRTL1
+"
+ ::= { ne843Dc1 43 }
+
+ne843Dc1Rls OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Redundancy Loss
+Value:
+Alarm report from RLS1
+"
+ ::= { ne843Dc1 44 }
+
+ne843Dc1Mman OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Multiple Manual Off
+Value:
+Alarm report from MMAN1
+"
+ ::= { ne843Dc1 45 }
+
+ne843Dc1Macf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Multiple AC Failure
+Value:
+Alarm report from MACF1
+"
+ ::= { ne843Dc1 46 }
+
+ne843Dc1Bda OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Battery On Discharge
+Value:
+Alarm report from BDA1
+"
+ ::= { ne843Dc1 47 }
+
+ne843Dc1Hva OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"High Voltage
+Value:
+Alarm report from HVA1
+"
+ ::= { ne843Dc1 48 }
+
+ne843Dc1Hfv OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"High Float Voltage
+Value:
+Alarm report from HFV1
+"
+ ::= { ne843Dc1 49 }
+
+ne843Dc1Bdt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"BD Duration"
+ ::= { ne843Dc1 50 }
+
+ne843Dc1Ems OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Energy Management State"
+ ::= { ne843Dc1 51 }
+
+ne843Dc1Eme OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Energy Management Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Dc1 52 }
+
+ne843Dc1Emt OBJECT-TYPE
+SYNTAX Integer32(20..95)
+UNITS "%"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Efficiency Target (%)"
+ ::= { ne843Dc1 53 }
+
+ne843Dc1Emo OBJECT-TYPE
+SYNTAX Integer32(25..100)
+UNITS "%"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Efficiency Rectifier Turn On Threshold (%)"
+ ::= { ne843Dc1 54 }
+
+ne843Dc1Poc OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "%"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Percent of Charge (%)"
+ ::= { ne843Dc1 55 }
+
+ne843Dc1Emd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Energy Management Disabled
+Value:
+Alarm report from EMD1
+"
+ ::= { ne843Dc1 56 }
+
+ne843Dc1Pfs OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Thermal Probe Fail Safe
+Value:
+Alarm report from PFS1
+"
+ ::= { ne843Dc1 57 }
+
+ne843Dc1Rif OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Rectifier Internal Fault
+Value:
+Alarm report from RIF1
+"
+ ::= { ne843Dc1 58 }
+
+ne843Dc1Lsf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Load Share Fail
+Value:
+Alarm report from LSF1
+"
+ ::= { ne843Dc1 59 }
+
+ne843Dc1Emi OBJECT-TYPE
+SYNTAX Integer32(0..30)
+UNITS "Minutes"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Efficiency Initial Delay (Minutes)"
+ ::= { ne843Dc1 60 }
+
+ne843Dc1Emw OBJECT-TYPE
+SYNTAX Integer32(0..30)
+UNITS "Minutes"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Efficiency Turn Off Delay (Minutes)"
+ ::= { ne843Dc1 61 }
+
+ne843Dc1Aseq OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Automatic Sequencing
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Dc1 62 }
+
+ne843Dc1Isy OBJECT-TYPE
+SYNTAX Integer32(2..300)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Imminent Shutdown Delay"
+ ::= { ne843Dc1 63 }
+
+ne843Dc1Bofe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Backup ORing FET Test Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Dc1 64 }
+
+ne843Dc1Bof OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Rectifier ORing FET Fault
+Value:
+Alarm report from BOF1
+"
+ ::= { ne843Dc1 65 }
+
+ne843Dc1Sof OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Rectifier Shorted ORing FET
+Value:
+Alarm report from SOF1
+"
+ ::= { ne843Dc1 66 }
+
+ne843Dc1Der OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Rectifier Under Voltage
+Value:
+Alarm report from DER1
+"
+ ::= { ne843Dc1 67 }
+
+ne843Dc1Pmf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Probe Minimum Fail
+Value:
+Alarm report from PMF1
+"
+ ::= { ne843Dc1 68 }
+
+ne843Dc1Faja OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Distribution Fuse A
+Value:
+Alarm report from FAJA1
+"
+ ::= { ne843Dc1 69 }
+
+ne843Dc1Buht OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Bus Hi Temp
+Value:
+Alarm report from BUHT1
+"
+ ::= { ne843Dc1 70 }
+
+ne843Dc1Buvht OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Bus Very Hi Temp
+Value:
+Alarm report from BUVHT1
+"
+ ::= { ne843Dc1 71 }
+
+ne843Dc1Btha OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Batt Hi Temp
+Value:
+Alarm report from BTHA1
+"
+ ::= { ne843Dc1 72 }
+
+ne843Dc1Btvh OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Batt Very Hi Temp
+Value:
+Alarm report from BTVH1
+"
+ ::= { ne843Dc1 73 }
+
+ne843Dc1Btla OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Batt Low Temp
+Value:
+Alarm report from BTLA1
+"
+ ::= { ne843Dc1 74 }
+
+ne843Dc1Btvl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Batt Very Low Temp
+Value:
+Alarm report from BTVL1
+"
+ ::= { ne843Dc1 75 }
+
+ne843Dc1Laht OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Local Amb. Hi Temp
+Value:
+Alarm report from LAHT1
+"
+ ::= { ne843Dc1 76 }
+
+ne843Dc1Lalt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Local Amb. Low Temp
+Value:
+Alarm report from LALT1
+"
+ ::= { ne843Dc1 77 }
+
+ne843Dc1Raht OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Remote Amb. Hi Temp
+Value:
+Alarm report from RAHT
+"
+ ::= { ne843Dc1 78 }
+
+ne843Dc1Ravht OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Remote Amb. Very Hi Temp
+Value:
+Alarm report from RAVHT1
+"
+ ::= { ne843Dc1 79 }
+
+ne843Dc1Ralt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Remote Amb. Low Temp
+Value:
+Alarm report from RALT1
+"
+ ::= { ne843Dc1 80 }
+
+ne843Dc1Vlva OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"VA Power Loss
+Value:
+Alarm report from VLVA1
+"
+ ::= { ne843Dc1 81 }
+
+ne843Dc1Vlvb OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"VB Power Loss
+Value:
+Alarm report from VLBB1
+"
+ ::= { ne843Dc1 82 }
+
+ne843Dc1Ovla OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"IA Overload
+Value:
+Alarm report from OVLA1
+"
+ ::= { ne843Dc1 83 }
+
+ne843Dc1Ovlb OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"IB Overload
+Value:
+Alarm report from OVLB1
+"
+ ::= { ne843Dc1 84 }
+
+ne843Dc1Pcaux OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"PIC Auxiliary
+Value:
+Alarm report from PCAUX1
+"
+ ::= { ne843Dc1 85 }
+
+ne843Dc1Slot OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"PIC Slot
+Value:
+Alarm report from SLOT1
+"
+ ::= { ne843Dc1 86 }
+
+ne843Dc1Bod1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Battery On Discharge
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843Dc1 87 }
+
+ne843Dc1Bdt1 OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Seconds"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"BD Duration (Seconds)"
+ ::= { ne843Dc1 88 }
+
+ne843Dc1Poc1 OBJECT-TYPE
+SYNTAX Integer32(0..100)
+UNITS "%"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Percent of Charge (%)"
+ ::= { ne843Dc1 89 }
+
+ne843Dc1Fajb OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Distribution Fuse B
+Value:
+Alarm report from FAJB1
+"
+ ::= { ne843Dc1 90 }
+
+ne843Dc1Smw OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Shunt Mis-wired
+Value:
+Alarm report from SMW1
+"
+ ::= { ne843Dc1 91 }
+
+ne843Dc1Cca OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Circuit Assignment
+Value:
+Alarm report from CCA1
+"
+ ::= { ne843Dc1 92 }
+
+
+--
+-- object ne843Ps1
+--
+
+ne843Ps1 OBJECT IDENTIFIER ::= { ne843 2 }
+
+ne843Ps1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Ps1 1 }
+
+ne843Ps1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Ps1 2 }
+
+ne843Ps1Sid OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Site ID"
+ ::= { ne843Ps1 3 }
+
+ne843Ps1Sde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Site Description"
+ ::= { ne843Ps1 4 }
+
+ne843Ps1Sys OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"System Description"
+ ::= { ne843Ps1 5 }
+
+ne843Ps1Swv OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Software Version"
+ ::= { ne843Ps1 6 }
+
+ne843Ps1Verw OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Web Page Version"
+ ::= { ne843Ps1 7 }
+
+ne843Ps1Verb OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Boot Block Version"
+ ::= { ne843Ps1 8 }
+
+ne843Ps1Verd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Display Version"
+ ::= { ne843Ps1 9 }
+
+ne843Ps1Dflt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Defaults Version"
+ ::= { ne843Ps1 10 }
+
+ne843Ps1Brc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Board Code"
+ ::= { ne843Ps1 11 }
+
+ne843Ps1Sn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Serial Number"
+ ::= { ne843Ps1 12 }
+
+ne843Ps1Dat OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"System Date"
+ ::= { ne843Ps1 13 }
+
+ne843Ps1Dtf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Date Format
+Values:
+mm/dd/yyyy,
+dd/mm/yyyy,
+yyyy/mm/dd
+"
+ ::= { ne843Ps1 14 }
+
+ne843Ps1Tim OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"System Time"
+ ::= { ne843Ps1 15 }
+
+ne843Ps1Tmf OBJECT-TYPE
+SYNTAX INTEGER {
+h12(12),
+h24(24)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"System Time Format
+Values:
+h12(12),
+h24(24)
+"
+ ::= { ne843Ps1 16 }
+
+ne843Ps1Dls OBJECT-TYPE
+SYNTAX INTEGER {
+off(0),
+on(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Daylight Saving
+Values:
+off(0),
+on(1)
+"
+ ::= { ne843Ps1 17 }
+
+ne843Ps1Lng OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Front Panel Language
+Values:
+ENGLISH,
+OTHER
+"
+ ::= { ne843Ps1 18 }
+
+ne843Ps1Tun OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Temperature Units
+Values:
+C,
+F
+"
+ ::= { ne843Ps1 19 }
+
+ne843Ps1Cem OBJECT-TYPE
+SYNTAX INTEGER {
+off(0),
+on(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Critical Equals Major
+Values:
+off(0),
+on(1)
+"
+ ::= { ne843Ps1 20 }
+
+ne843Ps1Fpc OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Front Panel Configuration
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Ps1 21 }
+
+ne843Ps1Rrf OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Remote Rectifier Off
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Ps1 22 }
+
+ne843Ps1Poe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Power Off Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Ps1 23 }
+
+ne843Ps1Usl OBJECT-TYPE
+SYNTAX INTEGER {
+uninstall(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Uninstall Missing Equipment
+Values:
+uninstall(1)
+"
+ ::= { ne843Ps1 24 }
+
+ne843Ps1Usr OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Enable User Accounts
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Ps1 25 }
+
+ne843Ps1Ptt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Communication Port Type
+Values:
+LOCAL,
+MODEM
+"
+ ::= { ne843Ps1 26 }
+
+ne843Ps1Amt OBJECT-TYPE
+SYNTAX Integer32
+UNITS "C"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ambient Temperature (C)"
+ ::= { ne843Ps1 27 }
+
+ne843Ps1Fst OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Factory Defaults"
+ ::= { ne843Ps1 28 }
+
+ne843Ps1Fstl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Factory Defaults List"
+ ::= { ne843Ps1 29 }
+
+ne843Ps1Fpe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Front Panel Pin Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Ps1 30 }
+
+ne843Ps1Fpt OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Front Panel Pin Timeout"
+ ::= { ne843Ps1 31 }
+
+ne843Ps1Rss OBJECT-TYPE
+SYNTAX INTEGER {
+restart(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Restart Devices
+Values:
+restart(1)
+"
+ ::= { ne843Ps1 32 }
+
+ne843Ps1Ast OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"System Alarm State"
+ ::= { ne843Ps1 33 }
+
+ne843Ps1Dss OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Daylight Saving Start mon:wk:dow:min or, mon:-1:dom:min"
+ ::= { ne843Ps1 34 }
+
+ne843Ps1Dse OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Daylight Saving End mon:wk:dow:min or, mon:-1:dom:min"
+ ::= { ne843Ps1 35 }
+
+ne843Ps1Epr OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"External Password Reset
+Value:
+Alarm report from EPR1
+"
+ ::= { ne843Ps1 36 }
+
+ne843Ps1Pfd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Passwords At Default
+Value:
+Alarm report from PFD1
+"
+ ::= { ne843Ps1 37 }
+
+ne843Ps1Exl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Excessive Login Attempts
+Value:
+Alarm report from EXL1
+"
+ ::= { ne843Ps1 38 }
+
+ne843Ps1Bbl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Memory Backup Battery Low
+Value:
+Alarm report from BBL1
+"
+ ::= { ne843Ps1 39 }
+
+ne843Ps1Clc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Clock Changed
+Value:
+Alarm report from CLC1
+"
+ ::= { ne843Ps1 40 }
+
+ne843Ps1Stf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Self Test Failed
+Value:
+Alarm report from STF1
+"
+ ::= { ne843Ps1 41 }
+
+ne843Ps1Pgi OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Program Line Invalid
+Value:
+Alarm report from PGI1
+"
+ ::= { ne843Ps1 42 }
+
+ne843Ps1Cch OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Configuration Changed
+Value:
+Alarm report from CCH1
+"
+ ::= { ne843Ps1 43 }
+
+ne843Ps1Hcl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"History Cleared
+Value:
+Alarm report from HCL1
+"
+ ::= { ne843Ps1 44 }
+
+ne843Ps1Ax1 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Auxiliary Event 1
+Value:
+Alarm report from AUX1
+"
+ ::= { ne843Ps1 45 }
+
+ne843Ps1Ax2 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Auxiliary Event 2
+Value:
+Alarm report from AUX2
+"
+ ::= { ne843Ps1 46 }
+
+ne843Ps1Ax3 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Auxiliary Event 3
+Value:
+Alarm report from AUX3
+"
+ ::= { ne843Ps1 47 }
+
+ne843Ps1Ax4 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Auxiliary Event 4
+Value:
+Alarm report from AUX4
+"
+ ::= { ne843Ps1 48 }
+
+ne843Ps1Ax5 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Auxiliary Event 5
+Value:
+Alarm report from AUX5
+"
+ ::= { ne843Ps1 49 }
+
+ne843Ps1Ax6 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Auxiliary Event 6
+Value:
+Alarm report from AUX6
+"
+ ::= { ne843Ps1 50 }
+
+ne843Ps1Fan24 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"24 V Fuse Minor
+Value:
+Alarm report from FAN1
+"
+ ::= { ne843Ps1 51 }
+
+ne843Ps1Fan48 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"48 V Fuse Minor
+Value:
+Alarm report from FAN2
+"
+ ::= { ne843Ps1 52 }
+
+ne843Ps1Faj24 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"24 V Fuse Major
+Value:
+Alarm report from FAJ1
+"
+ ::= { ne843Ps1 53 }
+
+ne843Ps1Faj48 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"48 V Fuse Major
+Value:
+Alarm report from FAJ2
+"
+ ::= { ne843Ps1 54 }
+
+ne843Ps1Accl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Relay List"
+ ::= { ne843Ps1 55 }
+
+ne843Ps1Ledl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"LED List"
+ ::= { ne843Ps1 56 }
+
+ne843Ps1Ax7 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Auxiliary Event 7
+Value:
+Alarm report from AUX7
+"
+ ::= { ne843Ps1 57 }
+
+ne843Ps1Ax8 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Auxiliary Event 8
+Value:
+Alarm report from AUX8
+"
+ ::= { ne843Ps1 58 }
+
+ne843Ps1Ax9 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Auxiliary Event 9
+Value:
+Alarm report from AUX9
+"
+ ::= { ne843Ps1 59 }
+
+ne843Ps1Ax10 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Auxiliary Event 10
+Value:
+Alarm report from AUX10
+"
+ ::= { ne843Ps1 60 }
+
+ne843Ps1Ax11 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Auxiliary Event 11
+Value:
+Alarm report from AUX11
+"
+ ::= { ne843Ps1 61 }
+
+ne843Ps1Ax12 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Auxiliary Event 12
+Value:
+Alarm report from AUX12
+"
+ ::= { ne843Ps1 62 }
+
+ne843Ps1Cid OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Controller Assignes IDs
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Ps1 63 }
+
+ne843Ps1Lngl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Available Languages"
+ ::= { ne843Ps1 64 }
+
+ne843Ps1Amtl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Low Ambient Temperature
+Value:
+Alarm report from AMTL1
+"
+ ::= { ne843Ps1 65 }
+
+ne843Ps1Amth OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"High Ambient Temperature
+Value:
+Alarm report from AMTH1
+"
+ ::= { ne843Ps1 66 }
+
+ne843Ps1Cc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Comcode"
+ ::= { ne843Ps1 67 }
+
+ne843Ps1Clei OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"CLEI Code"
+ ::= { ne843Ps1 68 }
+
+ne843Ps1Ser OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Series"
+ ::= { ne843Ps1 69 }
+
+ne843Ps1Lamt OBJECT-TYPE
+SYNTAX Integer32
+UNITS "C"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Lowest Ambient Temperature (C)"
+ ::= { ne843Ps1 70 }
+
+ne843Ps1Nat OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Ambient Temperature Probes Present"
+ ::= { ne843Ps1 71 }
+
+ne843Ps1Blr OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Bay Lamp Relay
+Values:
+,
+R1,
+R2,
+R3,
+R4,
+R5,
+R6,
+R7
+"
+ ::= { ne843Ps1 72 }
+
+ne843Ps1Tzo OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Minutes"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Timezone Offset (Minutes)"
+ ::= { ne843Ps1 73 }
+
+ne843Ps1Crt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Configuration Changed Reboot Required
+Value:
+Alarm report from CRT1
+"
+ ::= { ne843Ps1 74 }
+
+ne843Ps1Nhat OBJECT-TYPE
+SYNTAX Integer32
+UNITS "C"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Next Highest Ambient Temperature (C)"
+ ::= { ne843Ps1 75 }
+
+ne843Ps1Nal OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Total Alarms Active"
+ ::= { ne843Ps1 76 }
+
+ne843Ps1Ncr OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Total Critical Alarms Active"
+ ::= { ne843Ps1 77 }
+
+ne843Ps1Nmj OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Total Major Alarms Active"
+ ::= { ne843Ps1 78 }
+
+ne843Ps1Nmn OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Total Minor Alarms Active"
+ ::= { ne843Ps1 79 }
+
+ne843Ps1Nwa OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Total Warnings Active"
+ ::= { ne843Ps1 80 }
+
+ne843Ps1Nre OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Total Record Only Events Active"
+ ::= { ne843Ps1 81 }
+
+ne843Ps1Ere OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"PCR/PMJ/PMN Enahnced Relays Enabled
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Ps1 82 }
+
+
+--
+-- object ne843At1
+--
+
+ne843At1 OBJECT IDENTIFIER ::= { ne843 3 }
+
+ne843At1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843At1 1 }
+
+ne843At1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843At1 2 }
+
+ne843At1Stt OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Alarm Test Active
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843At1 3 }
+
+ne843At1Stg OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Stage"
+ ::= { ne843At1 4 }
+
+ne843At1Lte OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Alarm Test Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843At1 5 }
+
+ne843At1Dur OBJECT-TYPE
+SYNTAX Integer32(5..300)
+UNITS "Seconds"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Alarm Contact Duration (Seconds)"
+ ::= { ne843At1 6 }
+
+ne843At1Pcr OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Power Critical
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843At1 7 }
+
+ne843At1Pmj OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Power Major
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843At1 8 }
+
+ne843At1Pmn OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Power Minor
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843At1 9 }
+
+ne843At1R1 OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Test Relay 1
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843At1 10 }
+
+ne843At1R2 OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Test Relay 2
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843At1 11 }
+
+ne843At1R3 OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Test Relay 3
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843At1 12 }
+
+ne843At1R4 OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Test Relay 4
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843At1 13 }
+
+ne843At1R5 OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Test Relay 5
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843At1 14 }
+
+ne843At1R6 OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Test Relay 6
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843At1 15 }
+
+ne843At1R7 OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Test Relay 7
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843At1 16 }
+
+ne843At1Ets OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Do Email Test
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843At1 17 }
+
+ne843At1Ems OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Email Test Results"
+ ::= { ne843At1 18 }
+
+ne843At1Bzi OBJECT-TYPE
+SYNTAX Integer32(5..300)
+UNITS "Seconds"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Audio Test Duration (Seconds)"
+ ::= { ne843At1 19 }
+
+ne843At1Bzt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Audio Test Active
+Values:
+,
+LOCAL
+"
+ ::= { ne843At1 20 }
+
+ne843At1Irt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Individual Relay Test State
+Values:
+,
+PCR,
+PMJ,
+PMN,
+R1,
+R2,
+R3,
+R4,
+R5,
+R6,
+R7
+"
+ ::= { ne843At1 21 }
+
+ne843At1Ata OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Alarm Test Active
+Value:
+Alarm report from ATA1
+"
+ ::= { ne843At1 22 }
+
+ne843At1Atb OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Alarm Test Aborted
+Value:
+Alarm report from ATB1
+"
+ ::= { ne843At1 23 }
+
+ne843At1Snt OBJECT-TYPE
+SYNTAX INTEGER {
+start(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Email Test
+Values:
+start(1)
+"
+ ::= { ne843At1 24 }
+
+
+--
+-- table TRS
+--
+
+ne843TrsTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843TrsEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Trend data"
+ ::= { ne843 4 }
+
+ne843TrsEntry OBJECT-TYPE
+SYNTAX Ne843TrsEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Trend"
+INDEX { ne843TrsEntryIndex }
+ ::= { ne843TrsTable 1 }
+
+Ne843TrsEntry ::= SEQUENCE {
+ne843TrsEntryIndex INTEGER,
+ne843TrsEntryIde DisplayString,
+ne843TrsEntryDes DisplayString,
+ne843TrsEntrySrc DisplayString
+}
+
+ne843TrsEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843TrsEntry 1 }
+
+ne843TrsEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843TrsEntry 2 }
+
+ne843TrsEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843TrsEntry 3 }
+
+ne843TrsEntrySrc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Source"
+ ::= { ne843TrsEntry 4 }
+
+
+
+--
+-- object ne843Aco1
+--
+
+ne843Aco1 OBJECT IDENTIFIER ::= { ne843 5 }
+
+ne843Aco1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Aco1 1 }
+
+ne843Aco1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Aco1 2 }
+
+ne843Aco1Stt OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Alarm Cut-off State
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843Aco1 3 }
+
+ne843Aco1Cst OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Critical Alarm Cut-off State
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843Aco1 4 }
+
+ne843Aco1Cae OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Critical Alarm Cut-off Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Aco1 5 }
+
+ne843Aco1Cto OBJECT-TYPE
+SYNTAX Integer32(1..8)
+UNITS "Hours"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Critical Alarm Cut-off Timeout (Hours)"
+ ::= { ne843Aco1 6 }
+
+ne843Aco1Jst OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Major Alarm Cut-off State
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843Aco1 7 }
+
+ne843Aco1Jae OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Major Alarm Cut-off Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Aco1 8 }
+
+ne843Aco1Jto OBJECT-TYPE
+SYNTAX Integer32(1..8)
+UNITS "Hours"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Major Alarm Cut-off Timeout (Hours)"
+ ::= { ne843Aco1 9 }
+
+ne843Aco1Nst OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Minor Alarm Cut-off State
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843Aco1 10 }
+
+ne843Aco1Nae OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Minor Alarm Cut-off Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Aco1 11 }
+
+ne843Aco1Nto OBJECT-TYPE
+SYNTAX Integer32(1..72)
+UNITS "Hours"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Minor Alarm Cut-off Timeout (Hours)"
+ ::= { ne843Aco1 12 }
+
+ne843Aco1Lbe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Local Buzzer Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Aco1 13 }
+
+ne843Aco1Aac OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ACO Active
+Value:
+Alarm report from AAC1
+"
+ ::= { ne843Aco1 14 }
+
+
+--
+-- object ne843Gm1
+--
+
+ne843Gm1 OBJECT IDENTIFIER ::= { ne843 6 }
+
+ne843Gm1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Gm1 1 }
+
+ne843Gm1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Gm1 2 }
+
+ne843Gm1Lse OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Load Share Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Gm1 3 }
+
+ne843Gm1Rme OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Redundancy Monitor
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Gm1 4 }
+
+ne843Gm1Fsd OBJECT-TYPE
+SYNTAX Integer32(25000..30000|50000..60000)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Float High Voltage Shutdown (mV)"
+ ::= { ne843Gm1 5 }
+
+ne843Gm1Bsd OBJECT-TYPE
+SYNTAX Integer32(26000..30000|52000..60000)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Boost High Voltage Shutdown (mV)"
+ ::= { ne843Gm1 6 }
+
+ne843Gm1Fsp OBJECT-TYPE
+SYNTAX Integer32(22000..28000|44000..56500)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Float Set Point (mV)"
+ ::= { ne843Gm1 7 }
+
+ne843Gm1Bsp OBJECT-TYPE
+SYNTAX Integer32(22000..30000|48000..60000)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Boost Set Point (mV)"
+ ::= { ne843Gm1 8 }
+
+ne843Gm1Fcl OBJECT-TYPE
+SYNTAX Integer32(30..110)
+UNITS "%"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Float Current Limit (%)"
+ ::= { ne843Gm1 9 }
+
+ne843Gm1Bcl OBJECT-TYPE
+SYNTAX Integer32(30..110)
+UNITS "%"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Boost Current Limit (%)"
+ ::= { ne843Gm1 10 }
+
+ne843Gm1Oft OBJECT-TYPE
+SYNTAX INTEGER {
+start(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Or-ing FET Test
+Values:
+start(1)
+"
+ ::= { ne843Gm1 11 }
+
+ne843Gm1Wie OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Walk-in Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Gm1 12 }
+
+ne843Gm1Sof OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Shorted ORing FET Test Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Gm1 13 }
+
+ne843Gm1Lsfe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Load Share Fail Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Gm1 14 }
+
+ne843Gm1Nro OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Rectifiers On"
+ ::= { ne843Gm1 15 }
+
+ne843Gm1Lst OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Load Share Target"
+ ::= { ne843Gm1 16 }
+
+ne843Gm1Nro1 OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Rectifiers On"
+ ::= { ne843Gm1 17 }
+
+
+--
+-- table REC
+--
+
+ne843RecTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843RecEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Rectifier data"
+ ::= { ne843 7 }
+
+ne843RecEntry OBJECT-TYPE
+SYNTAX Ne843RecEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Rectifier"
+INDEX { ne843RecEntryIndex }
+ ::= { ne843RecTable 1 }
+
+Ne843RecEntry ::= SEQUENCE {
+ne843RecEntryIndex INTEGER,
+ne843RecEntryIde DisplayString,
+ne843RecEntryDes DisplayString,
+ne843RecEntryTyp DisplayString,
+ne843RecEntrySn DisplayString,
+ne843RecEntryAdc Integer32,
+ne843RecEntryVdc Integer32,
+ne843RecEntryStt DisplayString,
+ne843RecEntryCap Integer32,
+ne843RecEntryVac Integer32,
+ne843RecEntryAac Integer32,
+ne843RecEntryTmp Integer32,
+ne843RecEntrySeq INTEGER,
+ne843RecEntryRfa DisplayString,
+ne843RecEntryAcf DisplayString,
+ne843RecEntryMan DisplayString,
+ne843RecEntryDid DisplayString,
+ne843RecEntryClm DisplayString,
+ne843RecEntryRcf DisplayString,
+ne843RecEntryRfn DisplayString,
+ne843RecEntryRif DisplayString,
+ne843RecEntryLsf DisplayString,
+ne843RecEntryCc DisplayString,
+ne843RecEntryClei DisplayString,
+ne843RecEntrySer DisplayString,
+ne843RecEntryVerp DisplayString,
+ne843RecEntryVers DisplayString,
+ne843RecEntryLin DisplayString,
+ne843RecEntryHin DisplayString,
+ne843RecEntryBof DisplayString,
+ne843RecEntrySof DisplayString,
+ne843RecEntryDer DisplayString,
+ne843RecEntryEcap Integer32,
+ne843RecEntryEmod Integer32,
+ne843RecEntryMppt Integer32,
+ne843RecEntryRtm Integer32,
+ne843RecEntryVan Integer32,
+ne843RecEntryVac1 Integer32,
+ne843RecEntryAac1 Integer32,
+ne843RecEntryVac2 Integer32,
+ne843RecEntryAac2 Integer32,
+ne843RecEntryVac3 Integer32,
+ne843RecEntryAac3 Integer32,
+ne843RecEntryRfa1 INTEGER,
+ne843RecEntryAcf1 INTEGER,
+ne843RecEntryMan1 INTEGER,
+ne843RecEntryDid1 INTEGER,
+ne843RecEntryClm1 INTEGER,
+ne843RecEntryRcf1 INTEGER,
+ne843RecEntryRfn1 INTEGER,
+ne843RecEntryRif1 INTEGER,
+ne843RecEntryLsf1 INTEGER,
+ne843RecEntryLin1 INTEGER,
+ne843RecEntryHin1 INTEGER,
+ne843RecEntryBof1 INTEGER,
+ne843RecEntrySof1 INTEGER,
+ne843RecEntryDer1 INTEGER
+}
+
+ne843RecEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843RecEntry 1 }
+
+ne843RecEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843RecEntry 2 }
+
+ne843RecEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843RecEntry 3 }
+
+ne843RecEntryTyp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Type"
+ ::= { ne843RecEntry 4 }
+
+ne843RecEntrySn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Serial Number"
+ ::= { ne843RecEntry 5 }
+
+ne843RecEntryAdc OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"DC Current (Amps)"
+ ::= { ne843RecEntry 6 }
+
+ne843RecEntryVdc OBJECT-TYPE
+SYNTAX Integer32
+UNITS "mV"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"DC Voltage (mV)"
+ ::= { ne843RecEntry 7 }
+
+ne843RecEntryStt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"State
+Values:
+ON,
+OFF,
+STANDBY,
+VACANT
+"
+ ::= { ne843RecEntry 8 }
+
+ne843RecEntryCap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Capacity (Amps)"
+ ::= { ne843RecEntry 9 }
+
+ne843RecEntryVac OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Volts"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"AC Voltage (Volts)"
+ ::= { ne843RecEntry 10 }
+
+ne843RecEntryAac OBJECT-TYPE
+SYNTAX Integer32
+UNITS "mA"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"AC Current (mA)"
+ ::= { ne843RecEntry 11 }
+
+ne843RecEntryTmp OBJECT-TYPE
+SYNTAX Integer32
+UNITS "C"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Temperature (C)"
+ ::= { ne843RecEntry 12 }
+
+ne843RecEntrySeq OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Use in Sequence Enable
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843RecEntry 13 }
+
+ne843RecEntryRfa OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Rectifier Fail"
+ ::= { ne843RecEntry 14 }
+
+ne843RecEntryAcf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"AC Fail"
+ ::= { ne843RecEntry 15 }
+
+ne843RecEntryMan OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Standby or Manual Off"
+ ::= { ne843RecEntry 16 }
+
+ne843RecEntryDid OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ID Conflict"
+ ::= { ne843RecEntry 17 }
+
+ne843RecEntryClm OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Current Limit"
+ ::= { ne843RecEntry 18 }
+
+ne843RecEntryRcf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Communication Failure"
+ ::= { ne843RecEntry 19 }
+
+ne843RecEntryRfn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Fan Failure"
+ ::= { ne843RecEntry 20 }
+
+ne843RecEntryRif OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Internal Fault"
+ ::= { ne843RecEntry 21 }
+
+ne843RecEntryLsf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Loadshare Failure"
+ ::= { ne843RecEntry 22 }
+
+ne843RecEntryCc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Comcode"
+ ::= { ne843RecEntry 23 }
+
+ne843RecEntryClei OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"CLEI Code"
+ ::= { ne843RecEntry 24 }
+
+ne843RecEntrySer OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Series"
+ ::= { ne843RecEntry 25 }
+
+ne843RecEntryVerp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Primary Software Version"
+ ::= { ne843RecEntry 26 }
+
+ne843RecEntryVers OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Secondary Software Version"
+ ::= { ne843RecEntry 27 }
+
+ne843RecEntryLin OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Low Input"
+ ::= { ne843RecEntry 28 }
+
+ne843RecEntryHin OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"High Input"
+ ::= { ne843RecEntry 29 }
+
+ne843RecEntryBof OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ORing FET Fault"
+ ::= { ne843RecEntry 30 }
+
+ne843RecEntrySof OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Shorted ORing FET"
+ ::= { ne843RecEntry 31 }
+
+ne843RecEntryDer OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Under Voltage"
+ ::= { ne843RecEntry 32 }
+
+ne843RecEntryEcap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ECO Capacity (Amps)"
+ ::= { ne843RecEntry 33 }
+
+ne843RecEntryEmod OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ECO Mode"
+ ::= { ne843RecEntry 34 }
+
+ne843RecEntryMppt OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ECO MPPT"
+ ::= { ne843RecEntry 35 }
+
+ne843RecEntryRtm OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Run Time"
+ ::= { ne843RecEntry 36 }
+
+ne843RecEntryVan OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Anode Voltage"
+ ::= { ne843RecEntry 37 }
+
+ne843RecEntryVac1 OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Volts"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"AC Voltage (Volts) Phase 1"
+ ::= { ne843RecEntry 38 }
+
+ne843RecEntryAac1 OBJECT-TYPE
+SYNTAX Integer32
+UNITS "mA"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"AC Current (mA) Phase 1"
+ ::= { ne843RecEntry 39 }
+
+ne843RecEntryVac2 OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Volts"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"AC Voltage (Volts) Phase 2"
+ ::= { ne843RecEntry 40 }
+
+ne843RecEntryAac2 OBJECT-TYPE
+SYNTAX Integer32
+UNITS "mA"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"AC Current (mA) Phase 2"
+ ::= { ne843RecEntry 41 }
+
+ne843RecEntryVac3 OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Volts"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"AC Voltage (Volts) Phase 3"
+ ::= { ne843RecEntry 42 }
+
+ne843RecEntryAac3 OBJECT-TYPE
+SYNTAX Integer32
+UNITS "mA"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"AC Current (mA) Phase 3"
+ ::= { ne843RecEntry 43 }
+
+ne843RecEntryRfa1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Rectifier Fail
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RecEntry 44 }
+
+ne843RecEntryAcf1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"AC Fail
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RecEntry 45 }
+
+ne843RecEntryMan1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Standby or Manual Off
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RecEntry 46 }
+
+ne843RecEntryDid1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ID Conflict
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RecEntry 47 }
+
+ne843RecEntryClm1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Current Limit
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RecEntry 48 }
+
+ne843RecEntryRcf1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Communication Failure
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RecEntry 49 }
+
+ne843RecEntryRfn1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Fan Failure
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RecEntry 50 }
+
+ne843RecEntryRif1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Internal Fault
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RecEntry 51 }
+
+ne843RecEntryLsf1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Loadshare Failure
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RecEntry 52 }
+
+ne843RecEntryLin1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Low Input
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RecEntry 53 }
+
+ne843RecEntryHin1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"High Input
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RecEntry 54 }
+
+ne843RecEntryBof1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ORing FET Fault
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RecEntry 55 }
+
+ne843RecEntrySof1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Shorted ORing FET
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RecEntry 56 }
+
+ne843RecEntryDer1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Under Voltage
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RecEntry 57 }
+
+
+
+--
+-- object ne843Cp1
+--
+
+ne843Cp1 OBJECT IDENTIFIER ::= { ne843 8 }
+
+ne843Cp1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Cp1 1 }
+
+ne843Cp1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Cp1 2 }
+
+ne843Cp1Typ OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Type"
+ ::= { ne843Cp1 3 }
+
+ne843Cp1Vdc OBJECT-TYPE
+SYNTAX Integer32
+UNITS "mV"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"DC Voltage (mV)"
+ ::= { ne843Cp1 4 }
+
+ne843Cp1Adc OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"DC Current (Amps)"
+ ::= { ne843Cp1 5 }
+
+ne843Cp1Cap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Capacity (Amps)"
+ ::= { ne843Cp1 6 }
+
+ne843Cp1Olcap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"On Line Capacity (Amps)"
+ ::= { ne843Cp1 7 }
+
+ne843Cp1Vsp OBJECT-TYPE
+SYNTAX Integer32(23000..28000|46000..57000)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Voltage Set Point (mV)"
+ ::= { ne843Cp1 8 }
+
+ne843Cp1Vsd OBJECT-TYPE
+SYNTAX Integer32(25000..30000|50000..60000)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Internal High Voltage Shutdown (mV)"
+ ::= { ne843Cp1 9 }
+
+ne843Cp1Clm OBJECT-TYPE
+SYNTAX Integer32(30..100)
+UNITS "%"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Current Limit (%)"
+ ::= { ne843Cp1 10 }
+
+ne843Cp1Dth OBJECT-TYPE
+SYNTAX Integer32(20000..25000|40000..50000)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Low Voltage Disconnect (mV)"
+ ::= { ne843Cp1 11 }
+
+ne843Cp1Rth OBJECT-TYPE
+SYNTAX Integer32(22000..27000|44000..54000)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Low Voltage Reconnect (mV)"
+ ::= { ne843Cp1 12 }
+
+ne843Cp1Lvd OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Low Voltage Disconnect Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Cp1 13 }
+
+ne843Cp1Rss OBJECT-TYPE
+SYNTAX INTEGER {
+off(0),
+on(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Converter Restart
+Values:
+off(0),
+on(1)
+"
+ ::= { ne843Cp1 14 }
+
+ne843Cp1Rme OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Redundancy Monitor Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Cp1 15 }
+
+ne843Cp1Rof OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Remote Standby Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Cp1 16 }
+
+ne843Cp1Cfa OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Converter Fail
+Value:
+Alarm report from CFA1
+"
+ ::= { ne843Cp1 17 }
+
+ne843Cp1Cfn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Converter Fan Minor
+Value:
+Alarm report from CFN1
+"
+ ::= { ne843Cp1 18 }
+
+ne843Cp1Cfj OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Converter Fan Major
+Value:
+Alarm report from CFJ1
+"
+ ::= { ne843Cp1 19 }
+
+ne843Cp1Dfa OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Distribution Fail
+Value:
+Alarm report from CDFA1
+"
+ ::= { ne843Cp1 20 }
+
+ne843Cp1Did OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ID Conflict
+Value:
+Alarm report from CDID1
+"
+ ::= { ne843Cp1 21 }
+
+ne843Cp1Icc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Incompatible Converter Alarm
+Value:
+Alarm report from ICC1
+"
+ ::= { ne843Cp1 22 }
+
+ne843Cp1Mfa OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Multiple Converter Fail
+Value:
+Alarm report from CMFA1
+"
+ ::= { ne843Cp1 23 }
+
+ne843Cp1Hva OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Converter High Voltage Major
+Value:
+Alarm report from CHVA1
+"
+ ::= { ne843Cp1 24 }
+
+ne843Cp1Hfv OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Converter High Voltage Minor
+Value:
+Alarm report from CHFV1
+"
+ ::= { ne843Cp1 25 }
+
+ne843Cp1Vla OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Converter Very Low Voltage
+Value:
+Alarm report from CVLA
+"
+ ::= { ne843Cp1 26 }
+
+ne843Cp1Rl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Converter Redundancy Loss
+Value:
+Alarm report from CRL
+"
+ ::= { ne843Cp1 27 }
+
+ne843Cp1Cin OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Converter Input Fail
+Value:
+Alarm report from CIN1
+"
+ ::= { ne843Cp1 28 }
+
+
+--
+-- table DCC
+--
+
+ne843DccTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843DccEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Converter data"
+ ::= { ne843 9 }
+
+ne843DccEntry OBJECT-TYPE
+SYNTAX Ne843DccEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Converter"
+INDEX { ne843DccEntryIndex }
+ ::= { ne843DccTable 1 }
+
+Ne843DccEntry ::= SEQUENCE {
+ne843DccEntryIndex INTEGER,
+ne843DccEntryIde DisplayString,
+ne843DccEntryDes DisplayString,
+ne843DccEntryTyp DisplayString,
+ne843DccEntrySn DisplayString,
+ne843DccEntryAdc Integer32,
+ne843DccEntryCap Integer32,
+ne843DccEntryStt DisplayString,
+ne843DccEntryCfa DisplayString,
+ne843DccEntryDfa DisplayString,
+ne843DccEntryDid DisplayString,
+ne843DccEntryCcf DisplayString,
+ne843DccEntryCfn DisplayString,
+ne843DccEntryCfa1 INTEGER,
+ne843DccEntryDfa1 INTEGER,
+ne843DccEntryDid1 INTEGER,
+ne843DccEntryCcf1 INTEGER,
+ne843DccEntryCfn1 INTEGER
+}
+
+ne843DccEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843DccEntry 1 }
+
+ne843DccEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843DccEntry 2 }
+
+ne843DccEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843DccEntry 3 }
+
+ne843DccEntryTyp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Type"
+ ::= { ne843DccEntry 4 }
+
+ne843DccEntrySn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Serial Number"
+ ::= { ne843DccEntry 5 }
+
+ne843DccEntryAdc OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"DC Current (Amps)"
+ ::= { ne843DccEntry 6 }
+
+ne843DccEntryCap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Capacity (Amps)"
+ ::= { ne843DccEntry 7 }
+
+ne843DccEntryStt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"State
+Values:
+ON,
+OFF,
+STANDBY,
+VACANT
+"
+ ::= { ne843DccEntry 8 }
+
+ne843DccEntryCfa OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Converter Fail"
+ ::= { ne843DccEntry 9 }
+
+ne843DccEntryDfa OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Distribution Fuse Fail"
+ ::= { ne843DccEntry 10 }
+
+ne843DccEntryDid OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ID Conflict"
+ ::= { ne843DccEntry 11 }
+
+ne843DccEntryCcf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Communication Failure"
+ ::= { ne843DccEntry 12 }
+
+ne843DccEntryCfn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Fan Failure"
+ ::= { ne843DccEntry 13 }
+
+ne843DccEntryCfa1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Converter Fail
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843DccEntry 14 }
+
+ne843DccEntryDfa1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Distribution Fuse Fail
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843DccEntry 15 }
+
+ne843DccEntryDid1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ID Conflict
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843DccEntry 16 }
+
+ne843DccEntryCcf1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Communication Failure
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843DccEntry 17 }
+
+ne843DccEntryCfn1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Fan Failure Rev
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843DccEntry 18 }
+
+
+
+--
+-- object ne843Bs1
+--
+
+ne843Bs1 OBJECT IDENTIFIER ::= { ne843 10 }
+
+ne843Bs1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Bs1 1 }
+
+ne843Bs1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Bs1 2 }
+
+ne843Bs1Stt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"State
+Values:
+QRCT,
+MANUAL,
+BTP,
+TIMED AUTO,
+OFF
+"
+ ::= { ne843Bs1 3 }
+
+ne843Bs1Atm OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Auto Mode
+Values:
+OFF,
+QRCT,
+TIMED
+"
+ ::= { ne843Bs1 4 }
+
+ne843Bs1Tmd OBJECT-TYPE
+SYNTAX Integer32(1..80)
+UNITS "Hours"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Timed Manual Duration (Hours)"
+ ::= { ne843Bs1 5 }
+
+ne843Bs1Amf OBJECT-TYPE
+SYNTAX Integer32(1..9)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Auto Multiplication Factor"
+ ::= { ne843Bs1 6 }
+
+ne843Bs1Cta OBJECT-TYPE
+SYNTAX Integer32(0..999)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Current Terminated Current Threshold"
+ ::= { ne843Bs1 7 }
+
+
+--
+-- object ne843Sc1
+--
+
+ne843Sc1 OBJECT IDENTIFIER ::= { ne843 11 }
+
+ne843Sc1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Sc1 1 }
+
+ne843Sc1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Sc1 2 }
+
+ne843Sc1Stt OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"State
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Sc1 3 }
+
+ne843Sc1Rve OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Raise Voltage Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Sc1 4 }
+
+ne843Sc1Ltt OBJECT-TYPE
+SYNTAX Integer32
+UNITS "C"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Lower Temperature Threshold (C)"
+ ::= { ne843Sc1 5 }
+
+ne843Sc1Ntt OBJECT-TYPE
+SYNTAX Integer32
+UNITS "C"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Nominal Temperature Threshold (C)"
+ ::= { ne843Sc1 6 }
+
+ne843Sc1Utt OBJECT-TYPE
+SYNTAX Integer32
+UNITS "C"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Upper Temperature Threshold (C)"
+ ::= { ne843Sc1 7 }
+
+ne843Sc1Spt OBJECT-TYPE
+SYNTAX Integer32
+UNITS "C"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Step Temperature (C)"
+ ::= { ne843Sc1 8 }
+
+ne843Sc1Lsp OBJECT-TYPE
+SYNTAX Integer32(1..10)
+UNITS "mV/C"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Lower Temperature Slope/Cell (mV/C)"
+ ::= { ne843Sc1 9 }
+
+ne843Sc1Usp OBJECT-TYPE
+SYNTAX Integer32(1..10)
+UNITS "mV/C"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Upper Temperature Slope/Cell (mV/C)"
+ ::= { ne843Sc1 10 }
+
+ne843Sc1Fse OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Probe Fail-Safe Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Sc1 11 }
+
+
+--
+-- table BTD
+--
+
+ne843BtdTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843BtdEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Battery Type Definition data"
+ ::= { ne843 12 }
+
+ne843BtdEntry OBJECT-TYPE
+SYNTAX Ne843BtdEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Battery Type Definition"
+INDEX { ne843BtdEntryIndex }
+ ::= { ne843BtdTable 1 }
+
+Ne843BtdEntry ::= SEQUENCE {
+ne843BtdEntryIndex INTEGER,
+ne843BtdEntryIde DisplayString,
+ne843BtdEntryDes DisplayString,
+ne843BtdEntryBty DisplayString,
+ne843BtdEntryBtc DisplayString,
+ne843BtdEntryCap Integer32
+}
+
+ne843BtdEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843BtdEntry 1 }
+
+ne843BtdEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843BtdEntry 2 }
+
+ne843BtdEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843BtdEntry 3 }
+
+ne843BtdEntryBty OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Battery Type"
+ ::= { ne843BtdEntry 4 }
+
+ne843BtdEntryBtc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Battery Class
+Values:
+FLOODED,
+SEALED,
+NICD,
+LI_LMP,
+SODIUM
+"
+ ::= { ne843BtdEntry 5 }
+
+ne843BtdEntryCap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Capacity (Amps)"
+ ::= { ne843BtdEntry 6 }
+
+
+
+--
+-- object ne843Br1
+--
+
+ne843Br1 OBJECT IDENTIFIER ::= { ne843 13 }
+
+ne843Br1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Br1 1 }
+
+ne843Br1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Br1 2 }
+
+ne843Br1Adc OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Total Battery Current (Amps)"
+ ::= { ne843Br1 3 }
+
+ne843Br1Hbt OBJECT-TYPE
+SYNTAX Integer32
+UNITS "C"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Highest Battery Temperature (C)"
+ ::= { ne843Br1 4 }
+
+ne843Br1Cap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Installed Battery Capacity (Amps)"
+ ::= { ne843Br1 5 }
+
+ne843Br1Olcap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"On-line Battery Capacity (Amps)"
+ ::= { ne843Br1 6 }
+
+ne843Br1Btr OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Battery Test Results"
+ ::= { ne843Br1 7 }
+
+ne843Br1Tth OBJECT-TYPE
+SYNTAX Integer32(30..194)
+UNITS "C"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"High Temperature Threshold (C)"
+ ::= { ne843Br1 8 }
+
+ne843Br1Cle OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Current Limit Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Br1 9 }
+
+ne843Br1Clt OBJECT-TYPE
+SYNTAX Integer32(10..1000)
+UNITS "Amps"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Current Limit Threshold (Amps)"
+ ::= { ne843Br1 10 }
+
+ne843Br1Cev OBJECT-TYPE
+SYNTAX Integer32(19250..22750|40250..43750)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"End Volts per Cell (mV)"
+ ::= { ne843Br1 11 }
+
+ne843Br1Bts OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Battery Test State
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843Br1 12 }
+
+ne843Br1Mtt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Manual Test Type
+Values:
+DISABLE,
+20%,
+TIMED
+"
+ ::= { ne843Br1 13 }
+
+ne843Br1Tev OBJECT-TYPE
+SYNTAX Integer32(21000..27000|36000..48000)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Manual Test Alarm Voltage (mV)"
+ ::= { ne843Br1 14 }
+
+ne843Br1Tmd OBJECT-TYPE
+SYNTAX Integer32(100..99900)
+UNITS "Hours x 1000"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Manual Test Duration (Hours x 1000)"
+ ::= { ne843Br1 15 }
+
+ne843Br1Bte OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Automatic Test Type
+Values:
+DISABLE,
+20%,
+TIMED
+"
+ ::= { ne843Br1 16 }
+
+ne843Br1Btv OBJECT-TYPE
+SYNTAX Integer32(21000..26000|42000..52000)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Battery Test Rectifier Voltage (mV)"
+ ::= { ne843Br1 17 }
+
+ne843Br1Ath OBJECT-TYPE
+SYNTAX Integer32(0..23)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Auto Test Hour"
+ ::= { ne843Br1 18 }
+
+ne843Br1Tin OBJECT-TYPE
+SYNTAX Integer32(1..18)
+UNITS "Months"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Auto Test Interval (Months)"
+ ::= { ne843Br1 19 }
+
+ne843Br1Atw OBJECT-TYPE
+SYNTAX Integer32(0..240)
+UNITS "Hours"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Auto Test Minimum wait after BD (Hours)"
+ ::= { ne843Br1 20 }
+
+ne843Br1Atd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Auto Test Date"
+ ::= { ne843Br1 21 }
+
+ne843Br1Nvm OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Mid-cell V Present"
+ ::= { ne843Br1 22 }
+
+ne843Br1Ntm OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Temperature Probes Present"
+ ::= { ne843Br1 23 }
+
+ne843Br1Scd OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Battery Voltage Imbalance Detection
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Br1 24 }
+
+ne843Br1Scv OBJECT-TYPE
+SYNTAX Integer32(1500..3000)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Battery Imbalance Threshold (mV)"
+ ::= { ne843Br1 25 }
+
+ne843Br1Bta OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Battery Test Active
+Value:
+Alarm report from BTA1
+"
+ ::= { ne843Br1 26 }
+
+ne843Br1Bfa OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Battery Test Failed
+Value:
+Alarm report from BFA1
+"
+ ::= { ne843Br1 27 }
+
+ne843Br1Scda OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Shorted Cell Detected
+Value:
+Alarm report from SCD1
+"
+ ::= { ne843Br1 28 }
+
+ne843Br1Isda OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Imminent Shutdown
+Value:
+Alarm report from ISD1
+"
+ ::= { ne843Br1 29 }
+
+ne843Br1Mdp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Voltage Duplicate ID
+Value:
+Alarm report from MDP1
+"
+ ::= { ne843Br1 30 }
+
+ne843Br1Mzd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Voltage ID Not Configured
+Value:
+Alarm report from MZD1
+"
+ ::= { ne843Br1 31 }
+
+ne843Br1Btha OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"High Battery Temperature
+Value:
+Alarm report from BTHA1
+"
+ ::= { ne843Br1 32 }
+
+ne843Br1Lbt OBJECT-TYPE
+SYNTAX Integer32
+UNITS "C"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Lowest Battery Temperature (C)"
+ ::= { ne843Br1 33 }
+
+ne843Br1Btla OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Low Battery Temperature
+Value:
+Alarm report from BTLA1
+"
+ ::= { ne843Br1 34 }
+
+ne843Br1Btvh OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Very High Battery Temperature
+Value:
+Alarm report from BTVH1
+"
+ ::= { ne843Br1 35 }
+
+ne843Br1Btvl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Very Low Battery Temperature
+Value:
+Alarm report from BTVL1
+"
+ ::= { ne843Br1 36 }
+
+ne843Br1Rba OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Reverse Battery
+Value:
+Alarm report from RBA1
+"
+ ::= { ne843Br1 37 }
+
+
+--
+-- table CNT
+--
+
+ne843CntTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843CntEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Contactor data"
+ ::= { ne843 14 }
+
+ne843CntEntry OBJECT-TYPE
+SYNTAX Ne843CntEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Contactor"
+INDEX { ne843CntEntryIndex }
+ ::= { ne843CntTable 1 }
+
+Ne843CntEntry ::= SEQUENCE {
+ne843CntEntryIndex INTEGER,
+ne843CntEntryIde DisplayString,
+ne843CntEntryDes DisplayString,
+ne843CntEntryStt DisplayString,
+ne843CntEntryEna INTEGER,
+ne843CntEntryDth Integer32,
+ne843CntEntryDdy DisplayString,
+ne843CntEntryDam INTEGER,
+ne843CntEntryDtm DisplayString,
+ne843CntEntryRth Integer32,
+ne843CntEntryRdy DisplayString,
+ne843CntEntryRam INTEGER,
+ne843CntEntryRtm DisplayString,
+ne843CntEntryCno DisplayString,
+ne843CntEntryCnf DisplayString,
+ne843CntEntryDvx Integer32,
+ne843CntEntryDin Integer32,
+ne843CntEntryDix Integer32,
+ne843CntEntryDvt Integer32,
+ne843CntEntryDtd DisplayString,
+ne843CntEntryDtp Integer32,
+ne843CntEntryRtd DisplayString,
+ne843CntEntryRtp Integer32
+}
+
+ne843CntEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843CntEntry 1 }
+
+ne843CntEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843CntEntry 2 }
+
+ne843CntEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843CntEntry 3 }
+
+ne843CntEntryStt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Status
+Values:
+NONE,
+DISCON,
+CONNECT,
+FAILED
+"
+ ::= { ne843CntEntry 4 }
+
+ne843CntEntryEna OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Control
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843CntEntry 5 }
+
+ne843CntEntryDth OBJECT-TYPE
+SYNTAX Integer32(19000..25000|39000..50000)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Disconnect Threshold (mV)"
+ ::= { ne843CntEntry 6 }
+
+ne843CntEntryDdy OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Disconnect Delay"
+ ::= { ne843CntEntry 7 }
+
+ne843CntEntryDam OBJECT-TYPE
+SYNTAX INTEGER {
+none(0),
+voltage(1),
+voltageAndTime(2),
+adaptive(3),
+temperature(4),
+voltageandtemperature(5),
+voltageandtimeandtemperature(6),
+adaptiveandtemperature(7)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Disconnect Automode
+Values:
+none(0),
+voltage(1),
+voltageAndTime(2),
+adaptive(3),
+temperature(4),
+voltageandtemperature(5),
+voltageandtimeandtemperature(6),
+adaptiveandtemperature(7)
+"
+ ::= { ne843CntEntry 8 }
+
+ne843CntEntryDtm OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Disconnect Time Remaining"
+ ::= { ne843CntEntry 9 }
+
+ne843CntEntryRth OBJECT-TYPE
+SYNTAX Integer32(19500..27000|39000..55000)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Reconnect Threshold (mV)"
+ ::= { ne843CntEntry 10 }
+
+ne843CntEntryRdy OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Reconnect Delay"
+ ::= { ne843CntEntry 11 }
+
+ne843CntEntryRam OBJECT-TYPE
+SYNTAX INTEGER {
+none(0),
+voltage(1),
+voltageAndTime(2),
+adaptive(3),
+temperature(4),
+voltageandtemperature(5),
+voltageandtimeandtemperature(6),
+adaptiveandtemperature(7)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Reconnect Automode
+Values:
+none(0),
+voltage(1),
+voltageAndTime(2),
+adaptive(3),
+temperature(4),
+voltageandtemperature(5),
+voltageandtimeandtemperature(6),
+adaptiveandtemperature(7)
+"
+ ::= { ne843CntEntry 12 }
+
+ne843CntEntryRtm OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Reconnect Time Remaining"
+ ::= { ne843CntEntry 13 }
+
+ne843CntEntryCno OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Contactor Open"
+ ::= { ne843CntEntry 14 }
+
+ne843CntEntryCnf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Contactor Failed"
+ ::= { ne843CntEntry 15 }
+
+ne843CntEntryDvx OBJECT-TYPE
+SYNTAX Integer32(39000..50000)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"VMax in Adaptive Mode (mV)"
+ ::= { ne843CntEntry 16 }
+
+ne843CntEntryDin OBJECT-TYPE
+SYNTAX Integer32(0..9999000)
+UNITS "mA"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"IMin in Adaptive Mode (mA)"
+ ::= { ne843CntEntry 17 }
+
+ne843CntEntryDix OBJECT-TYPE
+SYNTAX Integer32(0..9999000)
+UNITS "mA"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"IMax in Adaptive Mode (mA)"
+ ::= { ne843CntEntry 18 }
+
+ne843CntEntryDvt OBJECT-TYPE
+SYNTAX Integer32
+UNITS "mV"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Calculated Disconnect Voltage (mV)"
+ ::= { ne843CntEntry 19 }
+
+ne843CntEntryDtd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Disconnect Temperature Delay"
+ ::= { ne843CntEntry 20 }
+
+ne843CntEntryDtp OBJECT-TYPE
+SYNTAX Integer32(1125..5625)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Disconnect Temperature"
+ ::= { ne843CntEntry 21 }
+
+ne843CntEntryRtd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Reconnect Temperature Delay"
+ ::= { ne843CntEntry 22 }
+
+ne843CntEntryRtp OBJECT-TYPE
+SYNTAX Integer32(1080..5400)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Reconnect Temperature"
+ ::= { ne843CntEntry 23 }
+
+
+
+--
+-- table DCN
+--
+
+ne843DcnTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843DcnEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Distribution Contactor Interface data"
+ ::= { ne843 15 }
+
+ne843DcnEntry OBJECT-TYPE
+SYNTAX Ne843DcnEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Distribution Contactor Interface"
+INDEX { ne843DcnEntryIndex }
+ ::= { ne843DcnTable 1 }
+
+Ne843DcnEntry ::= SEQUENCE {
+ne843DcnEntryIndex INTEGER,
+ne843DcnEntryIde DisplayString,
+ne843DcnEntryDes DisplayString,
+ne843DcnEntryStt DisplayString,
+ne843DcnEntryTyp DisplayString,
+ne843DcnEntrySn DisplayString,
+ne843DcnEntryBrc DisplayString
+}
+
+ne843DcnEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843DcnEntry 1 }
+
+ne843DcnEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843DcnEntry 2 }
+
+ne843DcnEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843DcnEntry 3 }
+
+ne843DcnEntryStt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"State
+Values:
+NONE,
+MISSING,
+PRESENT,
+OPEN,
+CLOSED
+"
+ ::= { ne843DcnEntry 4 }
+
+ne843DcnEntryTyp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Contactor Interface Type
+Values:
+NONE,
+CN1,
+CN2,
+CN3,
+CN4
+"
+ ::= { ne843DcnEntry 5 }
+
+ne843DcnEntrySn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Serial Number"
+ ::= { ne843DcnEntry 6 }
+
+ne843DcnEntryBrc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Board Code"
+ ::= { ne843DcnEntry 7 }
+
+
+
+--
+-- table DCM
+--
+
+ne843DcmTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843DcmEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Distribution Current Monitor data"
+ ::= { ne843 16 }
+
+ne843DcmEntry OBJECT-TYPE
+SYNTAX Ne843DcmEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Distribution Current Monitor"
+INDEX { ne843DcmEntryIndex }
+ ::= { ne843DcmTable 1 }
+
+Ne843DcmEntry ::= SEQUENCE {
+ne843DcmEntryIndex INTEGER,
+ne843DcmEntryIde DisplayString,
+ne843DcmEntryDes DisplayString,
+ne843DcmEntryStt DisplayString,
+ne843DcmEntryTyp DisplayString,
+ne843DcmEntryVal Integer32,
+ne843DcmEntrySha Integer32,
+ne843DcmEntrySn DisplayString,
+ne843DcmEntryBrc DisplayString,
+ne843DcmEntryKwh DisplayString
+}
+
+ne843DcmEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843DcmEntry 1 }
+
+ne843DcmEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843DcmEntry 2 }
+
+ne843DcmEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843DcmEntry 3 }
+
+ne843DcmEntryStt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"State
+Values:
+NONE,
+MISSING,
+PRESENT
+"
+ ::= { ne843DcmEntry 4 }
+
+ne843DcmEntryTyp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Shunt Type
+Values:
+NONE,
+LOAD,
+BATTERY
+"
+ ::= { ne843DcmEntry 5 }
+
+ne843DcmEntryVal OBJECT-TYPE
+SYNTAX Integer32
+UNITS "mA"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Reading (mA)"
+ ::= { ne843DcmEntry 6 }
+
+ne843DcmEntrySha OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Shunt Rating (Amps)"
+ ::= { ne843DcmEntry 7 }
+
+ne843DcmEntrySn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Serial Number"
+ ::= { ne843DcmEntry 8 }
+
+ne843DcmEntryBrc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Board Code"
+ ::= { ne843DcmEntry 9 }
+
+ne843DcmEntryKwh OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "kWh"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Kilo Watt Hours (kWh)"
+ ::= { ne843DcmEntry 10 }
+
+
+
+--
+-- table UDE
+--
+
+ne843UdeTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843UdeEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all User Defined Event data"
+ ::= { ne843 17 }
+
+ne843UdeEntry OBJECT-TYPE
+SYNTAX Ne843UdeEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one User Defined Event"
+INDEX { ne843UdeEntryIndex }
+ ::= { ne843UdeTable 1 }
+
+Ne843UdeEntry ::= SEQUENCE {
+ne843UdeEntryIndex INTEGER,
+ne843UdeEntryIde DisplayString,
+ne843UdeEntryDes DisplayString,
+ne843UdeEntryFds DisplayString,
+ne843UdeEntryAst DisplayString,
+ne843UdeEntrySev DisplayString,
+ne843UdeEntryPrg DisplayString,
+ne843UdeEntryDur DisplayString,
+ne843UdeEntryLed DisplayString,
+ne843UdeEntryLat INTEGER,
+ne843UdeEntryAcc DisplayString,
+ne843UdeEntryDly Integer32,
+ne843UdeEntryNoo INTEGER,
+ne843UdeEntryNor INTEGER,
+ne843UdeEntryNag INTEGER,
+ne843UdeEntryDst DisplayString,
+ne843UdeEntryAst1 INTEGER
+}
+
+ne843UdeEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843UdeEntry 1 }
+
+ne843UdeEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843UdeEntry 2 }
+
+ne843UdeEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843UdeEntry 3 }
+
+ne843UdeEntryFds OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Front Panel Description"
+ ::= { ne843UdeEntry 4 }
+
+ne843UdeEntryAst OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Alarm State"
+ ::= { ne843UdeEntry 5 }
+
+ne843UdeEntrySev OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Severity
+Values:
+CRIT,
+MAJ,
+MIN,
+WRN,
+RO
+"
+ ::= { ne843UdeEntry 6 }
+
+ne843UdeEntryPrg OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Program Line"
+ ::= { ne843UdeEntry 7 }
+
+ne843UdeEntryDur OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Minimum Duration"
+ ::= { ne843UdeEntry 8 }
+
+ne843UdeEntryLed OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"LED
+Values:
+BD,
+AC,
+DC,
+
+"
+ ::= { ne843UdeEntry 9 }
+
+ne843UdeEntryLat OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Latched
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843UdeEntry 10 }
+
+ne843UdeEntryAcc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Contact Closure
+Values:
+,
+R1,
+R2,
+R3,
+R4,
+R5,
+R6,
+R7
+"
+ ::= { ne843UdeEntry 11 }
+
+ne843UdeEntryDly OBJECT-TYPE
+SYNTAX Integer32(0..540)
+UNITS "Seconds"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Notify Delay (Seconds)"
+ ::= { ne843UdeEntry 12 }
+
+ne843UdeEntryNoo OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Notify on Occur
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843UdeEntry 13 }
+
+ne843UdeEntryNor OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Notify on Retire
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843UdeEntry 14 }
+
+ne843UdeEntryNag OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"NAG on Occur
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843UdeEntry 15 }
+
+ne843UdeEntryDst OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Notify Destination"
+ ::= { ne843UdeEntry 16 }
+
+ne843UdeEntryAst1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Alarm State
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843UdeEntry 17 }
+
+
+
+--
+-- object ne843Cm1
+--
+
+ne843Cm1 OBJECT IDENTIFIER ::= { ne843 18 }
+
+ne843Cm1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Cm1 1 }
+
+ne843Cm1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Cm1 2 }
+
+ne843Cm1Ngi OBJECT-TYPE
+SYNTAX Integer32(15..60)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Nag Interval"
+ ::= { ne843Cm1 3 }
+
+ne843Cm1Cof OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Queue Overflow
+Value:
+Alarm report from COF1
+"
+ ::= { ne843Cm1 4 }
+
+ne843Cm1Cor OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number Did Not Respond
+Value:
+Alarm report from COR1
+"
+ ::= { ne843Cm1 5 }
+
+ne843Cm1Nnc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number Not Configured
+Value:
+Alarm report from NNC1
+"
+ ::= { ne843Cm1 6 }
+
+
+--
+-- table COP
+--
+
+ne843CopTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843CopEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Call Out Phone Number data"
+ ::= { ne843 19 }
+
+ne843CopEntry OBJECT-TYPE
+SYNTAX Ne843CopEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Call Out Phone Number"
+INDEX { ne843CopEntryIndex }
+ ::= { ne843CopTable 1 }
+
+Ne843CopEntry ::= SEQUENCE {
+ne843CopEntryIndex INTEGER,
+ne843CopEntryIde DisplayString,
+ne843CopEntryDes DisplayString,
+ne843CopEntryTyp DisplayString,
+ne843CopEntryPhn DisplayString,
+ne843CopEntryBdr INTEGER,
+ne843CopEntryDbt INTEGER,
+ne843CopEntryPry DisplayString,
+ne843CopEntrySbt INTEGER,
+ne843CopEntryDly Integer32,
+ne843CopEntryPgr DisplayString,
+ne843CopEntryMsg DisplayString
+}
+
+ne843CopEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843CopEntry 1 }
+
+ne843CopEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843CopEntry 2 }
+
+ne843CopEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843CopEntry 3 }
+
+ne843CopEntryTyp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Type
+Values:
+DATA,
+PAGER
+"
+ ::= { ne843CopEntry 4 }
+
+ne843CopEntryPhn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Phone Number"
+ ::= { ne843CopEntry 5 }
+
+ne843CopEntryBdr OBJECT-TYPE
+SYNTAX INTEGER {
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Connect Baudrate
+Values:
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+"
+ ::= { ne843CopEntry 6 }
+
+ne843CopEntryDbt OBJECT-TYPE
+SYNTAX INTEGER {
+d7(7),
+d8(8)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Data Bits
+Values:
+d7(7),
+d8(8)
+"
+ ::= { ne843CopEntry 7 }
+
+ne843CopEntryPry OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parity
+Values:
+O,
+E,
+N
+"
+ ::= { ne843CopEntry 8 }
+
+ne843CopEntrySbt OBJECT-TYPE
+SYNTAX INTEGER {
+s1(1),
+s2(2)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Bits
+Values:
+s1(1),
+s2(2)
+"
+ ::= { ne843CopEntry 9 }
+
+ne843CopEntryDly OBJECT-TYPE
+SYNTAX Integer32(0..9)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Pager ID Delay"
+ ::= { ne843CopEntry 10 }
+
+ne843CopEntryPgr OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Pager ID"
+ ::= { ne843CopEntry 11 }
+
+ne843CopEntryMsg OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Pager Message"
+ ::= { ne843CopEntry 12 }
+
+
+
+--
+-- table COE
+--
+
+ne843CoeTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843CoeEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Email Address data"
+ ::= { ne843 20 }
+
+ne843CoeEntry OBJECT-TYPE
+SYNTAX Ne843CoeEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Email Address"
+INDEX { ne843CoeEntryIndex }
+ ::= { ne843CoeTable 1 }
+
+Ne843CoeEntry ::= SEQUENCE {
+ne843CoeEntryIndex INTEGER,
+ne843CoeEntryIde DisplayString,
+ne843CoeEntryDes DisplayString,
+ne843CoeEntryAdr DisplayString,
+ne843CoeEntryTyp DisplayString
+}
+
+ne843CoeEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843CoeEntry 1 }
+
+ne843CoeEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843CoeEntry 2 }
+
+ne843CoeEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843CoeEntry 3 }
+
+ne843CoeEntryAdr OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Email Address"
+ ::= { ne843CoeEntry 4 }
+
+ne843CoeEntryTyp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Address Type
+Values:
+NORMAL,
+PAGER
+"
+ ::= { ne843CoeEntry 5 }
+
+
+
+--
+-- table SND
+--
+
+ne843SndTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843SndEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all SNMP Trap Destination data"
+ ::= { ne843 21 }
+
+ne843SndEntry OBJECT-TYPE
+SYNTAX Ne843SndEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one SNMP Trap Destination"
+INDEX { ne843SndEntryIndex }
+ ::= { ne843SndTable 1 }
+
+Ne843SndEntry ::= SEQUENCE {
+ne843SndEntryIndex INTEGER,
+ne843SndEntryIde DisplayString,
+ne843SndEntryDes DisplayString,
+ne843SndEntryIp DisplayString,
+ne843SndEntryCs DisplayString
+}
+
+ne843SndEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843SndEntry 1 }
+
+ne843SndEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843SndEntry 2 }
+
+ne843SndEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843SndEntry 3 }
+
+ne843SndEntryIp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"IP Address"
+ ::= { ne843SndEntry 4 }
+
+ne843SndEntryCs OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Community String"
+ ::= { ne843SndEntry 5 }
+
+
+
+--
+-- object ne843Po1
+--
+
+ne843Po1 OBJECT IDENTIFIER ::= { ne843 22 }
+
+ne843Po1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Po1 1 }
+
+ne843Po1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Po1 2 }
+
+ne843Po1Phn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Phone Number"
+ ::= { ne843Po1 3 }
+
+ne843Po1Bdr OBJECT-TYPE
+SYNTAX INTEGER {
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Connect Baudrate
+Values:
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+"
+ ::= { ne843Po1 4 }
+
+ne843Po1Dbt OBJECT-TYPE
+SYNTAX INTEGER {
+d7(7),
+d8(8)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Data Bits
+Values:
+d7(7),
+d8(8)
+"
+ ::= { ne843Po1 5 }
+
+ne843Po1Pry OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parity
+Values:
+O,
+E,
+N
+"
+ ::= { ne843Po1 6 }
+
+ne843Po1Sbt OBJECT-TYPE
+SYNTAX INTEGER {
+s1(1),
+s2(2)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Bits
+Values:
+s1(1),
+s2(2)
+"
+ ::= { ne843Po1 7 }
+
+ne843Po1Int OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Interval
+Values:
+Sunday,
+Monday,
+Tuesday,
+Wednesday,
+Thursday,
+Friday,
+Saturday,
+Daily,
+Monthly,
+Quarterly,
+Never
+"
+ ::= { ne843Po1 8 }
+
+ne843Po1Tim OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Time"
+ ::= { ne843Po1 9 }
+
+ne843Po1Cl01 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Command Line 1"
+ ::= { ne843Po1 10 }
+
+ne843Po1Cl02 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Command Line 2"
+ ::= { ne843Po1 11 }
+
+ne843Po1Cl03 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Command Line 3"
+ ::= { ne843Po1 12 }
+
+ne843Po1Cl04 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Command Line 4"
+ ::= { ne843Po1 13 }
+
+ne843Po1Cl05 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Command Line 5"
+ ::= { ne843Po1 14 }
+
+ne843Po1Cl06 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Command Line 6"
+ ::= { ne843Po1 15 }
+
+ne843Po1Cl07 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Command Line 7"
+ ::= { ne843Po1 16 }
+
+ne843Po1Cl08 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Command Line 8"
+ ::= { ne843Po1 17 }
+
+ne843Po1Cl09 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Command Line 9"
+ ::= { ne843Po1 18 }
+
+ne843Po1Cl10 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Command Line 10"
+ ::= { ne843Po1 19 }
+
+ne843Po1Por OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number Did Not Respond
+Value:
+Alarm report from POR1
+"
+ ::= { ne843Po1 20 }
+
+
+--
+-- object ne843Cb1
+--
+
+ne843Cb1 OBJECT IDENTIFIER ::= { ne843 23 }
+
+ne843Cb1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Cb1 1 }
+
+ne843Cb1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Cb1 2 }
+
+ne843Cb1Stt OBJECT-TYPE
+SYNTAX INTEGER {
+off(0),
+on(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"State
+Values:
+off(0),
+on(1)
+"
+ ::= { ne843Cb1 3 }
+
+ne843Cb1Ph1 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Call-Back Phone Number 1"
+ ::= { ne843Cb1 4 }
+
+ne843Cb1Br1 OBJECT-TYPE
+SYNTAX INTEGER {
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Connect Baudrate 1
+Values:
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+"
+ ::= { ne843Cb1 5 }
+
+ne843Cb1Ph2 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Call-Back Phone Number 2"
+ ::= { ne843Cb1 6 }
+
+ne843Cb1Br2 OBJECT-TYPE
+SYNTAX INTEGER {
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Connect Baudrate 2
+Values:
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+"
+ ::= { ne843Cb1 7 }
+
+ne843Cb1Ph3 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Call-Back Phone Number 3"
+ ::= { ne843Cb1 8 }
+
+ne843Cb1Br3 OBJECT-TYPE
+SYNTAX INTEGER {
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Connect Baudrate 3
+Values:
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+"
+ ::= { ne843Cb1 9 }
+
+ne843Cb1Ph4 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Call-Back Phone Number 4"
+ ::= { ne843Cb1 10 }
+
+ne843Cb1Br4 OBJECT-TYPE
+SYNTAX INTEGER {
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Connect Baudrate 4
+Values:
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+"
+ ::= { ne843Cb1 11 }
+
+ne843Cb1Ph5 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Call-Back Phone Number 5"
+ ::= { ne843Cb1 12 }
+
+ne843Cb1Br5 OBJECT-TYPE
+SYNTAX INTEGER {
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Connect Baudrate 5
+Values:
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+"
+ ::= { ne843Cb1 13 }
+
+
+--
+-- object ne843Mp1
+--
+
+ne843Mp1 OBJECT IDENTIFIER ::= { ne843 24 }
+
+ne843Mp1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Mp1 1 }
+
+ne843Mp1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Mp1 2 }
+
+ne843Mp1Stt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"State"
+ ::= { ne843Mp1 3 }
+
+ne843Mp1Bdr OBJECT-TYPE
+SYNTAX INTEGER {
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Baudrate
+Values:
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+"
+ ::= { ne843Mp1 4 }
+
+ne843Mp1Dbt OBJECT-TYPE
+SYNTAX INTEGER {
+d7(7),
+d8(8)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Data Bits
+Values:
+d7(7),
+d8(8)
+"
+ ::= { ne843Mp1 5 }
+
+ne843Mp1Pry OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parity
+Values:
+O,
+E,
+N
+"
+ ::= { ne843Mp1 6 }
+
+ne843Mp1Sbt OBJECT-TYPE
+SYNTAX INTEGER {
+s1(1),
+s2(2)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Bits
+Values:
+s1(1),
+s2(2)
+"
+ ::= { ne843Mp1 7 }
+
+ne843Mp1Tmo OBJECT-TYPE
+SYNTAX Integer32(0..45)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Time-Out"
+ ::= { ne843Mp1 8 }
+
+ne843Mp1Hsh OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Handshaking
+Values:
+NO,
+SW
+"
+ ::= { ne843Mp1 9 }
+
+ne843Mp1Nrg OBJECT-TYPE
+SYNTAX Integer32(2..15)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Number of Rings Before Answer"
+ ::= { ne843Mp1 10 }
+
+ne843Mp1Wre OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Write Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Mp1 11 }
+
+ne843Mp1Ins OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Modem Init String"
+ ::= { ne843Mp1 12 }
+
+
+--
+-- object ne843Lp1
+--
+
+ne843Lp1 OBJECT IDENTIFIER ::= { ne843 25 }
+
+ne843Lp1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Lp1 1 }
+
+ne843Lp1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Lp1 2 }
+
+ne843Lp1Stt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"State"
+ ::= { ne843Lp1 3 }
+
+ne843Lp1Bdr OBJECT-TYPE
+SYNTAX INTEGER {
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Baudrate
+Values:
+b300(300),
+b1200(1200),
+b2400(2400),
+b4800(4800),
+b9600(9600),
+b19200(19200)
+"
+ ::= { ne843Lp1 4 }
+
+ne843Lp1Dbt OBJECT-TYPE
+SYNTAX INTEGER {
+d7(7),
+d8(8)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Data Bits
+Values:
+d7(7),
+d8(8)
+"
+ ::= { ne843Lp1 5 }
+
+ne843Lp1Pry OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parity
+Values:
+O,
+E,
+N
+"
+ ::= { ne843Lp1 6 }
+
+ne843Lp1Sbt OBJECT-TYPE
+SYNTAX INTEGER {
+s1(1),
+s2(2)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Bits
+Values:
+s1(1),
+s2(2)
+"
+ ::= { ne843Lp1 7 }
+
+ne843Lp1Tmo OBJECT-TYPE
+SYNTAX Integer32(0..45)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Time-Out"
+ ::= { ne843Lp1 8 }
+
+ne843Lp1Hsh OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Handshaking
+Values:
+NO,
+HW,
+SW
+"
+ ::= { ne843Lp1 9 }
+
+ne843Lp1App OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Application
+Values:
+TERMINAL,
+EVENT LOG
+"
+ ::= { ne843Lp1 10 }
+
+ne843Lp1Wre OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Write Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Lp1 11 }
+
+
+--
+-- object ne843Tlm1
+--
+
+ne843Tlm1 OBJECT IDENTIFIER ::= { ne843 26 }
+
+ne843Tlm1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Tlm1 1 }
+
+ne843Tlm1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Tlm1 2 }
+
+ne843Tlm1Aue OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Activate-User Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Tlm1 3 }
+
+ne843Tlm1Prt OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"TCP/IP Port"
+ ::= { ne843Tlm1 4 }
+
+ne843Tlm1Tmo OBJECT-TYPE
+SYNTAX Integer32(0..60)
+UNITS "Minutes"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Timeout (Minutes)"
+ ::= { ne843Tlm1 5 }
+
+
+--
+-- table TL1
+--
+
+ne843Tl1Table OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843Tl1Entry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all TL1 Object data"
+ ::= { ne843 27 }
+
+ne843Tl1Entry OBJECT-TYPE
+SYNTAX Ne843Tl1Entry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one TL1 Object"
+INDEX { ne843Tl1EntryIndex }
+ ::= { ne843Tl1Table 1 }
+
+Ne843Tl1Entry ::= SEQUENCE {
+ne843Tl1EntryIndex INTEGER,
+ne843Tl1EntryIde DisplayString,
+ne843Tl1EntryDes DisplayString,
+ne843Tl1EntryCds DisplayString,
+ne843Tl1EntryAid DisplayString,
+ne843Tl1EntryCnd DisplayString,
+ne843Tl1EntrySaf INTEGER,
+ne843Tl1EntryRpt DisplayString
+}
+
+ne843Tl1EntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843Tl1Entry 1 }
+
+ne843Tl1EntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Tl1Entry 2 }
+
+ne843Tl1EntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Tl1Entry 3 }
+
+ne843Tl1EntryCds OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Condition Description"
+ ::= { ne843Tl1Entry 4 }
+
+ne843Tl1EntryAid OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Aid"
+ ::= { ne843Tl1Entry 5 }
+
+ne843Tl1EntryCnd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Condition Type"
+ ::= { ne843Tl1Entry 6 }
+
+ne843Tl1EntrySaf OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Service Affecting
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843Tl1Entry 7 }
+
+ne843Tl1EntryRpt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Reporting
+Values:
+EQUIPMENT,
+ENVIRONMENT,
+PRESENCE
+"
+ ::= { ne843Tl1Entry 8 }
+
+
+
+--
+-- object ne843Net1
+--
+
+ne843Net1 OBJECT IDENTIFIER ::= { ne843 28 }
+
+ne843Net1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Net1 1 }
+
+ne843Net1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Net1 2 }
+
+ne843Net1Ead OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ethernet Address"
+ ::= { ne843Net1 3 }
+
+ne843Net1Dhcp OBJECT-TYPE
+SYNTAX INTEGER {
+static(0),
+dhcpClient(1),
+dhcpServer(2)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"IP Addressing Mode
+Values:
+static(0),
+dhcpClient(1),
+dhcpServer(2)
+"
+ ::= { ne843Net1 4 }
+
+ne843Net1Ip OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Static IPv4 Address"
+ ::= { ne843Net1 5 }
+
+ne843Net1Wip OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Working IPv4 Address"
+ ::= { ne843Net1 6 }
+
+ne843Net1Sub OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Subnet Mask"
+ ::= { ne843Net1 7 }
+
+ne843Net1Gtwy OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Default Gateway"
+ ::= { ne843Net1 8 }
+
+ne843Net1Host OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Host Name"
+ ::= { ne843Net1 9 }
+
+ne843Net1Dom OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Domain Name"
+ ::= { ne843Net1 10 }
+
+ne843Net1Dns OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"DNS Server Address"
+ ::= { ne843Net1 11 }
+
+ne843Net1Wre OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Write Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Net1 12 }
+
+ne843Net1Tmo OBJECT-TYPE
+SYNTAX Integer32(0..1440)
+UNITS "Minutes"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Timeout (Minutes)"
+ ::= { ne843Net1 13 }
+
+ne843Net1Msrv OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Mail Server Address"
+ ::= { ne843Net1 14 }
+
+ne843Net1Ntp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Time Server Address"
+ ::= { ne843Net1 15 }
+
+ne843Net1Sma OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Send Email As"
+ ::= { ne843Net1 16 }
+
+ne843Net1Sid OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"SNMP Engine ID"
+ ::= { ne843Net1 17 }
+
+ne843Net1Fpe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"FTP Access Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Net1 18 }
+
+ne843Net1Hpe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"HTTP Web Access Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Net1 19 }
+
+ne843Net1Hse OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"HTTPS Web Access Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Net1 20 }
+
+ne843Net1She OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"SSH Access Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Net1 21 }
+
+ne843Net1Sne OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"SNMP Access Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Net1 22 }
+
+ne843Net1Tle OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Telnet Access Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Net1 23 }
+
+ne843Net1Ip6 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Static IPv6 Address"
+ ::= { ne843Net1 24 }
+
+ne843Net1Gtwy6 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Static IPv6 Gateway/Router"
+ ::= { ne843Net1 25 }
+
+ne843Net1Wip6 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Working IPv6 Address"
+ ::= { ne843Net1 26 }
+
+ne843Net1Ll6 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Working IPv6 Link Local Address"
+ ::= { ne843Net1 27 }
+
+ne843Net1Pl6 OBJECT-TYPE
+SYNTAX Integer32(1..127)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"IPv6 Prefix Length"
+ ::= { ne843Net1 28 }
+
+ne843Net1Wgtwy6 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Working IPv6 Gateway/Router Address"
+ ::= { ne843Net1 29 }
+
+
+--
+-- table DRC
+--
+
+ne843DrcTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843DrcEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Derived Channel data"
+ ::= { ne843 29 }
+
+ne843DrcEntry OBJECT-TYPE
+SYNTAX Ne843DrcEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Derived Channel"
+INDEX { ne843DrcEntryIndex }
+ ::= { ne843DrcTable 1 }
+
+Ne843DrcEntry ::= SEQUENCE {
+ne843DrcEntryIndex INTEGER,
+ne843DrcEntryIde DisplayString,
+ne843DrcEntryDes DisplayString,
+ne843DrcEntryVal DisplayString,
+ne843DrcEntryPrg DisplayString,
+ne843DrcEntryUni DisplayString
+}
+
+ne843DrcEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843DrcEntry 1 }
+
+ne843DrcEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843DrcEntry 2 }
+
+ne843DrcEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843DrcEntry 3 }
+
+ne843DrcEntryVal OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Value"
+ ::= { ne843DrcEntry 4 }
+
+ne843DrcEntryPrg OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Program Line"
+ ::= { ne843DrcEntry 5 }
+
+ne843DrcEntryUni OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Unit"
+ ::= { ne843DrcEntry 6 }
+
+
+
+--
+-- table INP
+--
+
+ne843InpTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843InpEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Input Management data"
+ ::= { ne843 30 }
+
+ne843InpEntry OBJECT-TYPE
+SYNTAX Ne843InpEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Input Management"
+INDEX { ne843InpEntryIndex }
+ ::= { ne843InpTable 1 }
+
+Ne843InpEntry ::= SEQUENCE {
+ne843InpEntryIndex INTEGER,
+ne843InpEntryIde DisplayString,
+ne843InpEntryDes DisplayString,
+ne843InpEntryStt INTEGER,
+ne843InpEntryTyp DisplayString,
+ne843InpEntryPol DisplayString,
+ne843InpEntrySn DisplayString,
+ne843InpEntryBrc DisplayString
+}
+
+ne843InpEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843InpEntry 1 }
+
+ne843InpEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843InpEntry 2 }
+
+ne843InpEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843InpEntry 3 }
+
+ne843InpEntryStt OBJECT-TYPE
+SYNTAX INTEGER {
+alarming(1),
+nonAlarming(0)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Input State
+Values:
+alarming(1),
+nonAlarming(0)
+"
+ ::= { ne843InpEntry 4 }
+
+ne843InpEntryTyp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Type Alarm Object ID or, REMLVD for Remote LVD"
+ ::= { ne843InpEntry 5 }
+
+ne843InpEntryPol OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Input Alarming Polarity
+Values:
+OPEN,
+CLOSED
+"
+ ::= { ne843InpEntry 6 }
+
+ne843InpEntrySn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Serial Number"
+ ::= { ne843InpEntry 7 }
+
+ne843InpEntryBrc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Board Code"
+ ::= { ne843InpEntry 8 }
+
+
+
+--
+-- table MSV
+--
+
+ne843MsvTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843MsvEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Midstring Voltage Monitor data"
+ ::= { ne843 31 }
+
+ne843MsvEntry OBJECT-TYPE
+SYNTAX Ne843MsvEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Midstring Voltage Monitor"
+INDEX { ne843MsvEntryIndex }
+ ::= { ne843MsvTable 1 }
+
+Ne843MsvEntry ::= SEQUENCE {
+ne843MsvEntryIndex INTEGER,
+ne843MsvEntryIde DisplayString,
+ne843MsvEntryDes DisplayString,
+ne843MsvEntryStt DisplayString,
+ne843MsvEntryVal Integer32,
+ne843MsvEntryDid DisplayString,
+ne843MsvEntryDid1 INTEGER
+}
+
+ne843MsvEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843MsvEntry 1 }
+
+ne843MsvEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843MsvEntry 2 }
+
+ne843MsvEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843MsvEntry 3 }
+
+ne843MsvEntryStt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"State"
+ ::= { ne843MsvEntry 4 }
+
+ne843MsvEntryVal OBJECT-TYPE
+SYNTAX Integer32
+UNITS "mV"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Value (mV)"
+ ::= { ne843MsvEntry 5 }
+
+ne843MsvEntryDid OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Duplicate ID"
+ ::= { ne843MsvEntry 6 }
+
+ne843MsvEntryDid1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Duplicate ID
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843MsvEntry 7 }
+
+
+
+--
+-- object ne843Rp1
+--
+
+ne843Rp1 OBJECT IDENTIFIER ::= { ne843 32 }
+
+ne843Rp1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Rp1 1 }
+
+ne843Rp1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Rp1 2 }
+
+ne843Rp1Frq OBJECT-TYPE
+SYNTAX Integer32(15..50)
+UNITS "Hz"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Frequency (Hz)"
+ ::= { ne843Rp1 3 }
+
+ne843Rp1Vsp OBJECT-TYPE
+SYNTAX Integer32(65..100)
+UNITS "Volts"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Voltage Set-point (Volts)"
+ ::= { ne843Rp1 4 }
+
+ne843Rp1Ofe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Offset
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Rp1 5 }
+
+ne843Rp1Rme OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Redundancy Monitor
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Rp1 6 }
+
+ne843Rp1Rss OBJECT-TYPE
+SYNTAX INTEGER {
+restart(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Restart
+Values:
+restart(1)
+"
+ ::= { ne843Rp1 7 }
+
+ne843Rp1Rf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ringer Minor Fail
+Value:
+Alarm report from RFN1
+"
+ ::= { ne843Rp1 8 }
+
+ne843Rp1Rpff OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ringer Fan Fail
+Value:
+Alarm report from RPFF1
+"
+ ::= { ne843Rp1 9 }
+
+ne843Rp1Rprl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ringer Redundancy Loss
+Value:
+Alarm report from RPRL1
+"
+ ::= { ne843Rp1 10 }
+
+ne843Rp1Rpfj OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ringer Major Fail
+Value:
+Alarm report from RPFJ1
+"
+ ::= { ne843Rp1 11 }
+
+ne843Rp1Rpxj OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ringer Major External Fault
+Value:
+Alarm report from RPXJ1
+"
+ ::= { ne843Rp1 12 }
+
+ne843Rp1Rpxn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ringer Minor External Fault
+Value:
+Alarm report from RPXN1
+"
+ ::= { ne843Rp1 13 }
+
+ne843Rp1Rcdp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ringer ID Conflict
+Value:
+Alarm report from RCDP1
+"
+ ::= { ne843Rp1 14 }
+
+ne843Rp1Cap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "VA"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Capacity (VA)"
+ ::= { ne843Rp1 15 }
+
+ne843Rp1Olcap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "VA"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"On Line Capacity (VA)"
+ ::= { ne843Rp1 16 }
+
+ne843Rp1Va OBJECT-TYPE
+SYNTAX Integer32
+UNITS "VA"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Total (VA)"
+ ::= { ne843Rp1 17 }
+
+ne843Rp1Rrf OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Standby Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Rp1 18 }
+
+
+--
+-- table RCH
+--
+
+ne843RchTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843RchEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Ringer Chassis data"
+ ::= { ne843 33 }
+
+ne843RchEntry OBJECT-TYPE
+SYNTAX Ne843RchEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Ringer Chassis"
+INDEX { ne843RchEntryIndex }
+ ::= { ne843RchTable 1 }
+
+Ne843RchEntry ::= SEQUENCE {
+ne843RchEntryIndex INTEGER,
+ne843RchEntryIde DisplayString,
+ne843RchEntryDes DisplayString,
+ne843RchEntryStt DisplayString,
+ne843RchEntryVa Integer32,
+ne843RchEntryPri DisplayString,
+ne843RchEntrySec DisplayString,
+ne843RchEntryRf INTEGER,
+ne843RchEntryRpff INTEGER,
+ne843RchEntryRpxj INTEGER,
+ne843RchEntryRpxn INTEGER,
+ne843RchEntryRprl INTEGER,
+ne843RchEntryRpfj INTEGER,
+ne843RchEntryRcdp INTEGER,
+ne843RchEntryPsn DisplayString,
+ne843RchEntryPtyp DisplayString,
+ne843RchEntryPstt DisplayString,
+ne843RchEntrySsn DisplayString,
+ne843RchEntryStyp DisplayString,
+ne843RchEntrySstt DisplayString,
+ne843RchEntryCap Integer32
+}
+
+ne843RchEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843RchEntry 1 }
+
+ne843RchEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843RchEntry 2 }
+
+ne843RchEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843RchEntry 3 }
+
+ne843RchEntryStt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Ringer Group State"
+ ::= { ne843RchEntry 4 }
+
+ne843RchEntryVa OBJECT-TYPE
+SYNTAX Integer32
+UNITS "mVA"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ringer Output (mVA)"
+ ::= { ne843RchEntry 5 }
+
+ne843RchEntryPri OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Primary Ringer"
+ ::= { ne843RchEntry 6 }
+
+ne843RchEntrySec OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Secondary Ringer"
+ ::= { ne843RchEntry 7 }
+
+ne843RchEntryRf OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ringer Minor Fail
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RchEntry 8 }
+
+ne843RchEntryRpff OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ringer Fan Fail
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RchEntry 9 }
+
+ne843RchEntryRpxj OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ringer Major External Fault
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RchEntry 10 }
+
+ne843RchEntryRpxn OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ringer Minor External Fault
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RchEntry 11 }
+
+ne843RchEntryRprl OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ringer Redundancy Loss
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RchEntry 12 }
+
+ne843RchEntryRpfj OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ringer Major Fail
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RchEntry 13 }
+
+ne843RchEntryRcdp OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Ringer ID Conflict
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843RchEntry 14 }
+
+ne843RchEntryPsn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Primary Serial Number"
+ ::= { ne843RchEntry 15 }
+
+ne843RchEntryPtyp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Primary Type"
+ ::= { ne843RchEntry 16 }
+
+ne843RchEntryPstt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Primary Ringer State"
+ ::= { ne843RchEntry 17 }
+
+ne843RchEntrySsn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Secondary Serial Number"
+ ::= { ne843RchEntry 18 }
+
+ne843RchEntryStyp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Secondary Type"
+ ::= { ne843RchEntry 19 }
+
+ne843RchEntrySstt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Secondary Ringer State"
+ ::= { ne843RchEntry 20 }
+
+ne843RchEntryCap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "VA"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Capacity (VA)"
+ ::= { ne843RchEntry 21 }
+
+
+
+--
+-- table ALARM
+--
+
+ne843AlarmTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843AlarmEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Alarm data"
+ ::= { ne843 34 }
+
+ne843AlarmEntry OBJECT-TYPE
+SYNTAX Ne843AlarmEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Alarm"
+INDEX { ne843AlarmEntryIndex }
+ ::= { ne843AlarmTable 1 }
+
+Ne843AlarmEntry ::= SEQUENCE {
+ne843AlarmEntryIndex INTEGER,
+ne843AlarmEntryDes DisplayString,
+ne843AlarmEntryAst INTEGER,
+ne843AlarmEntrySev DisplayString,
+ne843AlarmEntryAcc DisplayString,
+ne843AlarmEntryThr DisplayString,
+ne843AlarmEntryFth Integer32,
+ne843AlarmEntryBth Integer32,
+ne843AlarmEntryDly Integer32,
+ne843AlarmEntryNoo INTEGER,
+ne843AlarmEntryNor INTEGER,
+ne843AlarmEntryNag INTEGER,
+ne843AlarmEntryDst DisplayString
+}
+
+ne843AlarmEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843AlarmEntry 1 }
+
+ne843AlarmEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843AlarmEntry 2 }
+
+ne843AlarmEntryAst OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"State
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843AlarmEntry 3 }
+
+ne843AlarmEntrySev OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Severity"
+ ::= { ne843AlarmEntry 4 }
+
+ne843AlarmEntryAcc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Contact Closure
+Values:
+,
+R1,
+R2,
+R3,
+R4,
+R5,
+R6,
+R7
+"
+ ::= { ne843AlarmEntry 5 }
+
+ne843AlarmEntryThr OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Threshold"
+ ::= { ne843AlarmEntry 6 }
+
+ne843AlarmEntryFth OBJECT-TYPE
+SYNTAX Integer32
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Float Threshold (mV)"
+ ::= { ne843AlarmEntry 7 }
+
+ne843AlarmEntryBth OBJECT-TYPE
+SYNTAX Integer32
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Boost Threshold (mV)"
+ ::= { ne843AlarmEntry 8 }
+
+ne843AlarmEntryDly OBJECT-TYPE
+SYNTAX Integer32(0..540)
+UNITS "Seconds"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Notify Delay (Seconds)"
+ ::= { ne843AlarmEntry 9 }
+
+ne843AlarmEntryNoo OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Notify On Occur
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843AlarmEntry 10 }
+
+ne843AlarmEntryNor OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Notify On Retire
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843AlarmEntry 11 }
+
+ne843AlarmEntryNag OBJECT-TYPE
+SYNTAX INTEGER {
+no(0),
+yes(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Nag on Occur
+Values:
+no(0),
+yes(1)
+"
+ ::= { ne843AlarmEntry 12 }
+
+ne843AlarmEntryDst OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Notify Destination"
+ ::= { ne843AlarmEntry 13 }
+
+
+
+--
+-- object ne843Trap
+--
+
+ne843Trap OBJECT IDENTIFIER ::= { ne843 35 }
+
+
+--
+-- object ne843TrapInfo
+--
+
+ne843TrapInfo OBJECT IDENTIFIER ::= { ne843 36 }
+
+ne843TrapDesc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS accessible-for-notify
+STATUS current
+DESCRIPTION
+ "Event Description"
+ ::= { ne843TrapInfo 1 }
+
+ne843TrapSev OBJECT-TYPE
+SYNTAX INTEGER {
+ retire(0),
+ record(1),
+ warning(2),
+ minor(3),
+ major(4),
+ critical(5)
+ }
+MAX-ACCESS accessible-for-notify
+STATUS current
+DESCRIPTION
+ "Event Severity"
+ ::= { ne843TrapInfo 2 }
+
+ne843TrapTime OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS accessible-for-notify
+STATUS current
+DESCRIPTION
+ "Time of Event"
+ ::= { ne843TrapInfo 3 }
+
+ne843TrapDate OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS accessible-for-notify
+STATUS current
+DESCRIPTION
+ "Date of Event"
+ ::= { ne843TrapInfo 4 }
+
+ne843TrapPath OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS accessible-for-notify
+STATUS current
+DESCRIPTION
+ "T1.317 Path of Event"
+ ::= { ne843TrapInfo 5 }
+
+
+ne843TrapDc1Amj NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Fuse Major"
+ ::= { ne843Trap 1 }
+
+ne843TrapDc1Vsf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Sense/Control Fuse"
+ ::= { ne843Trap 2 }
+
+ne843TrapDc1Osa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Open String"
+ ::= { ne843Trap 3 }
+
+ne843TrapDc1Zid NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "ID Not Configured"
+ ::= { ne843Trap 4 }
+
+ne843TrapDc1Tpa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Thermal Probe Alarm"
+ ::= { ne843Trap 5 }
+
+ne843TrapDc1Vmf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Voltage Module Fail"
+ ::= { ne843Trap 6 }
+
+ne843TrapDc1Cma NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Minor Communication Failure"
+ ::= { ne843Trap 7 }
+
+ne843TrapDc1Mcm NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Major Communication Failure"
+ ::= { ne843Trap 8 }
+
+ne843TrapDc1Epo NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Emergency Power Off"
+ ::= { ne843Trap 9 }
+
+ne843TrapDc1Icr NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Incompatible Rectifier"
+ ::= { ne843Trap 10 }
+
+ne843TrapDc1Rfa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Rectifier Fail"
+ ::= { ne843Trap 11 }
+
+ne843TrapDc1Acf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "AC Fail"
+ ::= { ne843Trap 12 }
+
+ne843TrapDc1Man NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Manual Off"
+ ::= { ne843Trap 13 }
+
+ne843TrapDc1Did NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "ID Conflict"
+ ::= { ne843Trap 14 }
+
+ne843TrapDc1Clm NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Rectifier Current Limit"
+ ::= { ne843Trap 15 }
+
+ne843TrapDc1Rfn NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Rectifier Fan Failure"
+ ::= { ne843Trap 16 }
+
+ne843TrapDc1Vla NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Very Low Voltage"
+ ::= { ne843Trap 17 }
+
+ne843TrapDc1Mfa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Multiple Rectifier Fail"
+ ::= { ne843Trap 18 }
+
+ne843TrapDc1Rtl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Reserve Time Low"
+ ::= { ne843Trap 19 }
+
+ne843TrapDc1Rrtl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Real-time Reserve Time Low"
+ ::= { ne843Trap 20 }
+
+ne843TrapDc1Rls NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Redundancy Loss"
+ ::= { ne843Trap 21 }
+
+ne843TrapDc1Mman NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Multiple Manual Off"
+ ::= { ne843Trap 22 }
+
+ne843TrapDc1Macf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Multiple AC Failure"
+ ::= { ne843Trap 23 }
+
+ne843TrapDc1Bda NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Battery On Discharge"
+ ::= { ne843Trap 24 }
+
+ne843TrapDc1Hva NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "High Voltage"
+ ::= { ne843Trap 25 }
+
+ne843TrapDc1Hfv NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "High Float Voltage"
+ ::= { ne843Trap 26 }
+
+ne843TrapPs1Epr NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "External Password Reset"
+ ::= { ne843Trap 27 }
+
+ne843TrapPs1Pfd NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Passwords At Default"
+ ::= { ne843Trap 28 }
+
+ne843TrapPs1Exl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Excessive Login Attempts"
+ ::= { ne843Trap 29 }
+
+ne843TrapPs1Bbl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Memory Backup Battery Low"
+ ::= { ne843Trap 30 }
+
+ne843TrapPs1Clc NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Clock Changed"
+ ::= { ne843Trap 31 }
+
+ne843TrapPs1Stf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Self Test Failed"
+ ::= { ne843Trap 32 }
+
+ne843TrapPs1Pgi NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Program Line Invalid"
+ ::= { ne843Trap 33 }
+
+ne843TrapPs1Cch NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Configuration Changed"
+ ::= { ne843Trap 34 }
+
+ne843TrapPs1Hcl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "History Cleared"
+ ::= { ne843Trap 35 }
+
+ne843TrapPs1Ax1 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 1"
+ ::= { ne843Trap 36 }
+
+ne843TrapPs1Ax2 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 2"
+ ::= { ne843Trap 37 }
+
+ne843TrapPs1Ax3 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 3"
+ ::= { ne843Trap 38 }
+
+ne843TrapPs1Ax4 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 4"
+ ::= { ne843Trap 39 }
+
+ne843TrapPs1Ax5 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 5"
+ ::= { ne843Trap 40 }
+
+ne843TrapPs1Ax6 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 6"
+ ::= { ne843Trap 41 }
+
+ne843TrapPs1Fan24 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "24 V Fuse Minor"
+ ::= { ne843Trap 42 }
+
+ne843TrapPs1Fan48 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "48 V Fuse Minor"
+ ::= { ne843Trap 43 }
+
+ne843TrapPs1Faj24 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "24 V Fuse Major"
+ ::= { ne843Trap 44 }
+
+ne843TrapPs1Faj48 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "48 V Fuse Major"
+ ::= { ne843Trap 45 }
+
+ne843TrapAt1Ata NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Alarm Test Active"
+ ::= { ne843Trap 46 }
+
+ne843TrapAt1Atb NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Alarm Test Aborted"
+ ::= { ne843Trap 47 }
+
+ne843TrapCp1Cfa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter Fail"
+ ::= { ne843Trap 48 }
+
+ne843TrapCp1Cfn NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter Fan Minor"
+ ::= { ne843Trap 49 }
+
+ne843TrapCp1Cfj NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter Fan Major"
+ ::= { ne843Trap 50 }
+
+ne843TrapCp1Dfa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Distribution Fail"
+ ::= { ne843Trap 51 }
+
+ne843TrapCp1Did NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "ID Conflict"
+ ::= { ne843Trap 52 }
+
+ne843TrapCp1Icc NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Incompatible Converter Alarm"
+ ::= { ne843Trap 53 }
+
+ne843TrapCp1Mfa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Multiple Converter Fail"
+ ::= { ne843Trap 54 }
+
+ne843TrapCp1Hva NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter High Voltage Major"
+ ::= { ne843Trap 55 }
+
+ne843TrapCp1Hfv NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter High Voltage Minor"
+ ::= { ne843Trap 56 }
+
+ne843TrapCp1Vla NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter Very Low Voltage"
+ ::= { ne843Trap 57 }
+
+ne843TrapCp1Rl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter Redundancy Loss"
+ ::= { ne843Trap 58 }
+
+ne843TrapBr1Bta NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Battery Test Active"
+ ::= { ne843Trap 59 }
+
+ne843TrapBr1Bfa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Battery Test Failed"
+ ::= { ne843Trap 60 }
+
+ne843TrapBr1Scda NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Shorted Cell Detected"
+ ::= { ne843Trap 61 }
+
+ne843TrapBr1Isda NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Imminent Shutdown"
+ ::= { ne843Trap 62 }
+
+ne843TrapBr1Mdp NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Voltage Duplicate ID"
+ ::= { ne843Trap 63 }
+
+ne843TrapBr1Mzd NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Voltage ID Not Configured"
+ ::= { ne843Trap 64 }
+
+ne843TrapBr1Btha NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "High Battery Temperature"
+ ::= { ne843Trap 65 }
+
+ne843TrapCn1Cno NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Open"
+ ::= { ne843Trap 66 }
+
+ne843TrapCn1Cnf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Failed"
+ ::= { ne843Trap 67 }
+
+ne843TrapCn2Cno NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Open"
+ ::= { ne843Trap 68 }
+
+ne843TrapCn2Cnf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Failed"
+ ::= { ne843Trap 69 }
+
+ne843TrapCn3Cno NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Open"
+ ::= { ne843Trap 70 }
+
+ne843TrapCn3Cnf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Failed"
+ ::= { ne843Trap 71 }
+
+ne843TrapCn4Cno NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Open"
+ ::= { ne843Trap 72 }
+
+ne843TrapCn4Cnf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Failed"
+ ::= { ne843Trap 73 }
+
+ne843TrapCm1Cof NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Queue Overflow"
+ ::= { ne843Trap 74 }
+
+ne843TrapCm1Cor NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Number Did Not Respond"
+ ::= { ne843Trap 75 }
+
+ne843TrapCm1Nnc NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Number Not Configured"
+ ::= { ne843Trap 76 }
+
+ne843TrapPo1Por NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Number Did Not Respond"
+ ::= { ne843Trap 77 }
+
+ne843TrapRp1Rf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Ringer Minor Fail"
+ ::= { ne843Trap 78 }
+
+ne843TrapRp1Rpff NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Ringer Fan Fail"
+ ::= { ne843Trap 79 }
+
+ne843TrapRp1Rprl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Ringer Redundancy Loss"
+ ::= { ne843Trap 80 }
+
+ne843TrapRp1Rpfj NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Ringer Major Fail"
+ ::= { ne843Trap 81 }
+
+ne843TrapRp1Rpxj NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Ringer Major External Fault"
+ ::= { ne843Trap 82 }
+
+ne843TrapRp1Rpxn NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Ringer Minor External Fault"
+ ::= { ne843Trap 83 }
+
+ne843TrapRp1Rcdp NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Ringer ID Conflict"
+ ::= { ne843Trap 84 }
+
+ne843TrapUserDefined NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "This may be a user defined event, or a new controller event."
+ ::= { ne843Trap 85 }
+
+ne843TrapDc1Emd NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Energy Management Disabled"
+ ::= { ne843Trap 86 }
+
+ne843TrapDc1Pfs NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Thermal Probe Fail Safe"
+ ::= { ne843Trap 87 }
+
+ne843TrapDc1Rif NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Rectifier Internal Fault"
+ ::= { ne843Trap 88 }
+
+ne843TrapDc1Lsf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Load Share Fail"
+ ::= { ne843Trap 89 }
+
+ne843TrapPs1Ax7 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 7"
+ ::= { ne843Trap 90 }
+
+ne843TrapPs1Ax8 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 8"
+ ::= { ne843Trap 91 }
+
+ne843TrapPs1Ax9 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 9"
+ ::= { ne843Trap 92 }
+
+ne843TrapPs1Ax10 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 10"
+ ::= { ne843Trap 93 }
+
+ne843TrapPs1Ax11 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 11"
+ ::= { ne843Trap 94 }
+
+ne843TrapPs1Ax12 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 12"
+ ::= { ne843Trap 95 }
+
+ne843TrapBr1Btla NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Low Battery Temperature"
+ ::= { ne843Trap 96 }
+
+ne843TrapBr1Btvh NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Very High Battery Temperature"
+ ::= { ne843Trap 97 }
+
+ne843TrapBr1Btvl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Very Low Battery Temperature"
+ ::= { ne843Trap 98 }
+
+ne843TrapGn1Gnr NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Generator Running"
+ ::= { ne843Trap 99 }
+
+ne843TrapGn1Gnm NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Generator Maintenance Required"
+ ::= { ne843Trap 100 }
+
+ne843TrapGn1Gnf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Generator Fail"
+ ::= { ne843Trap 101 }
+
+ne843TrapPs1Amtl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Low Ambient Temperature"
+ ::= { ne843Trap 102 }
+
+ne843TrapPs1Amth NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "High Ambient Temperature"
+ ::= { ne843Trap 103 }
+
+ne843TrapAco1Aac NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "ACO Active"
+ ::= { ne843Trap 104 }
+
+ne843TrapBr1Rba NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Reverse Battery"
+ ::= { ne843Trap 105 }
+
+ne843TrapCp1Cin NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter Input Fail"
+ ::= { ne843Trap 106 }
+
+ne843TrapDc1Bof NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Rectifier ORing FET Fault"
+ ::= { ne843Trap 107 }
+
+ne843TrapDc1Sof NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Rectifier Shorted ORing FET"
+ ::= { ne843Trap 108 }
+
+ne843TrapDc1Der NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Rectifier Under Voltage"
+ ::= { ne843Trap 109 }
+
+ne843TrapGn1Gns NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Generator Start"
+ ::= { ne843Trap 110 }
+
+ne843TrapIvp1Ilvi NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter Low Input"
+ ::= { ne843Trap 111 }
+
+ne843TrapIvp1Ihvi NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter High Input"
+ ::= { ne843Trap 112 }
+
+ne843TrapIvp1Ita NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter High Temperature"
+ ::= { ne843Trap 113 }
+
+ne843TrapIvp1If NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter Fail"
+ ::= { ne843Trap 114 }
+
+ne843TrapIvp1Ilv NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter Low Output"
+ ::= { ne843Trap 115 }
+
+ne843TrapIvp1Ifa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter Frequency Lock"
+ ::= { ne843Trap 116 }
+
+ne843TrapIvp1Ihv NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter High Output"
+ ::= { ne843Trap 117 }
+
+ne843TrapIvp1Ida NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter Distribution Alarm"
+ ::= { ne843Trap 118 }
+
+ne843TrapIvp1Iof NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter Output Fuse"
+ ::= { ne843Trap 119 }
+
+ne843TrapIvp1Idid NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter ID Conflict"
+ ::= { ne843Trap 120 }
+
+ne843TrapIvp1Iirm NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter High RMS Current"
+ ::= { ne843Trap 121 }
+
+ne843TrapIvp1Iipk NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter High Peak Current"
+ ::= { ne843Trap 122 }
+
+ne843TrapIvp1Icf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter High Crest Factor"
+ ::= { ne843Trap 123 }
+
+ne843TrapIvp1Mif NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Multiple Inverter Fail"
+ ::= { ne843Trap 124 }
+
+ne843TrapIvp1Irls NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter Redundancy Loss"
+ ::= { ne843Trap 125 }
+
+ne843TrapDc1Pmf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Probe Minimum Fail"
+ ::= { ne843Trap 126 }
+
+ne843TrapPs1Crt NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Configuration Changed Reboot Required"
+ ::= { ne843Trap 127 }
+
+ne843TrapIvp1Milv NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Multiple Inverter Low Input Voltage"
+ ::= { ne843Trap 128 }
+
+ne843TrapDc1Faja NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Distribution Fuse A"
+ ::= { ne843Trap 129 }
+
+ne843TrapDc1Buht NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Bus Hi Temp"
+ ::= { ne843Trap 130 }
+
+ne843TrapDc1Buvht NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Bus Very Hi Temp"
+ ::= { ne843Trap 131 }
+
+ne843TrapDc1Btha NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Batt Hi Temp"
+ ::= { ne843Trap 132 }
+
+ne843TrapDc1Btvh NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Batt Very Hi Temp"
+ ::= { ne843Trap 133 }
+
+ne843TrapDc1Btla NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Batt Low Temp"
+ ::= { ne843Trap 134 }
+
+ne843TrapDc1Btvl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Batt Very Low Temp"
+ ::= { ne843Trap 135 }
+
+ne843TrapDc1Laht NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Local Amb. Hi Temp"
+ ::= { ne843Trap 136 }
+
+ne843TrapDc1Lalt NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Local Amb. Low Temp"
+ ::= { ne843Trap 137 }
+
+ne843TrapDc1Raht NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Remote Amb. Hi Temp"
+ ::= { ne843Trap 138 }
+
+ne843TrapDc1Ravht NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Remote Amb. Very Hi Temp"
+ ::= { ne843Trap 139 }
+
+ne843TrapDc1Ralt NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Remote Amb. Low Temp"
+ ::= { ne843Trap 140 }
+
+ne843TrapDc1Vlva NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "VA Power Loss"
+ ::= { ne843Trap 141 }
+
+ne843TrapDc1Vlvb NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "VB Power Loss"
+ ::= { ne843Trap 142 }
+
+ne843TrapDc1Ovla NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "IA Overload"
+ ::= { ne843Trap 143 }
+
+ne843TrapDc1Ovlb NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "IB Overload"
+ ::= { ne843Trap 144 }
+
+ne843TrapDc1Pcaux NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "PIC Auxiliary"
+ ::= { ne843Trap 145 }
+
+ne843TrapDc1Slot NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "PIC Slot"
+ ::= { ne843Trap 146 }
+
+ne843TrapDc1Fajb NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Distribution Fuse B"
+ ::= { ne843Trap 147 }
+
+ne843TrapDc1Smw NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Shunt Mis-wired"
+ ::= { ne843Trap 148 }
+
+ne843TrapDc1Cca NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Circuit Assignment"
+ ::= { ne843Trap 149 }
+
+--
+-- object ne843Retire
+--
+
+ne843Retire OBJECT IDENTIFIER ::= { ne843 37 }
+
+
+ne843RetireDc1Amj NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Fuse Major"
+ ::= { ne843Retire 1 }
+
+ne843RetireDc1Vsf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Sense/Control Fuse"
+ ::= { ne843Retire 2 }
+
+ne843RetireDc1Osa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Open String"
+ ::= { ne843Retire 3 }
+
+ne843RetireDc1Zid NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "ID Not Configured"
+ ::= { ne843Retire 4 }
+
+ne843RetireDc1Tpa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Thermal Probe Alarm"
+ ::= { ne843Retire 5 }
+
+ne843RetireDc1Vmf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Voltage Module Fail"
+ ::= { ne843Retire 6 }
+
+ne843RetireDc1Cma NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Minor Communication Failure"
+ ::= { ne843Retire 7 }
+
+ne843RetireDc1Mcm NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Major Communication Failure"
+ ::= { ne843Retire 8 }
+
+ne843RetireDc1Epo NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Emergency Power Off"
+ ::= { ne843Retire 9 }
+
+ne843RetireDc1Icr NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Incompatible Rectifier"
+ ::= { ne843Retire 10 }
+
+ne843RetireDc1Rfa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Rectifier Fail"
+ ::= { ne843Retire 11 }
+
+ne843RetireDc1Acf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "AC Fail"
+ ::= { ne843Retire 12 }
+
+ne843RetireDc1Man NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Manual Off"
+ ::= { ne843Retire 13 }
+
+ne843RetireDc1Did NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "ID Conflict"
+ ::= { ne843Retire 14 }
+
+ne843RetireDc1Clm NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Rectifier Current Limit"
+ ::= { ne843Retire 15 }
+
+ne843RetireDc1Rfn NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Rectifier Fan Failure"
+ ::= { ne843Retire 16 }
+
+ne843RetireDc1Vla NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Very Low Voltage"
+ ::= { ne843Retire 17 }
+
+ne843RetireDc1Mfa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Multiple Rectifier Fail"
+ ::= { ne843Retire 18 }
+
+ne843RetireDc1Rtl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Reserve Time Low"
+ ::= { ne843Retire 19 }
+
+ne843RetireDc1Rrtl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Real-time Reserve Time Low"
+ ::= { ne843Retire 20 }
+
+ne843RetireDc1Rls NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Redundancy Loss"
+ ::= { ne843Retire 21 }
+
+ne843RetireDc1Mman NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Multiple Manual Off"
+ ::= { ne843Retire 22 }
+
+ne843RetireDc1Macf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Multiple AC Failure"
+ ::= { ne843Retire 23 }
+
+ne843RetireDc1Bda NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Battery On Discharge"
+ ::= { ne843Retire 24 }
+
+ne843RetireDc1Hva NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "High Voltage"
+ ::= { ne843Retire 25 }
+
+ne843RetireDc1Hfv NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "High Float Voltage"
+ ::= { ne843Retire 26 }
+
+ne843RetirePs1Epr NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "External Password Reset"
+ ::= { ne843Retire 27 }
+
+ne843RetirePs1Pfd NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Passwords At Default"
+ ::= { ne843Retire 28 }
+
+ne843RetirePs1Exl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Excessive Login Attempts"
+ ::= { ne843Retire 29 }
+
+ne843RetirePs1Bbl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Memory Backup Battery Low"
+ ::= { ne843Retire 30 }
+
+ne843RetirePs1Clc NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Clock Changed"
+ ::= { ne843Retire 31 }
+
+ne843RetirePs1Stf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Self Test Failed"
+ ::= { ne843Retire 32 }
+
+ne843RetirePs1Pgi NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Program Line Invalid"
+ ::= { ne843Retire 33 }
+
+ne843RetirePs1Cch NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Configuration Changed"
+ ::= { ne843Retire 34 }
+
+ne843RetirePs1Hcl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "History Cleared"
+ ::= { ne843Retire 35 }
+
+ne843RetirePs1Ax1 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 1"
+ ::= { ne843Retire 36 }
+
+ne843RetirePs1Ax2 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 2"
+ ::= { ne843Retire 37 }
+
+ne843RetirePs1Ax3 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 3"
+ ::= { ne843Retire 38 }
+
+ne843RetirePs1Ax4 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 4"
+ ::= { ne843Retire 39 }
+
+ne843RetirePs1Ax5 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 5"
+ ::= { ne843Retire 40 }
+
+ne843RetirePs1Ax6 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 6"
+ ::= { ne843Retire 41 }
+
+ne843RetirePs1Fan24 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "24 V Fuse Minor"
+ ::= { ne843Retire 42 }
+
+ne843RetirePs1Fan48 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "48 V Fuse Minor"
+ ::= { ne843Retire 43 }
+
+ne843RetirePs1Faj24 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "24 V Fuse Major"
+ ::= { ne843Retire 44 }
+
+ne843RetirePs1Faj48 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "48 V Fuse Major"
+ ::= { ne843Retire 45 }
+
+ne843RetireAt1Ata NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Alarm Test Active"
+ ::= { ne843Retire 46 }
+
+ne843RetireAt1Atb NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Alarm Test Aborted"
+ ::= { ne843Retire 47 }
+
+ne843RetireCp1Cfa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter Fail"
+ ::= { ne843Retire 48 }
+
+ne843RetireCp1Cfn NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter Fan Minor"
+ ::= { ne843Retire 49 }
+
+ne843RetireCp1Cfj NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter Fan Major"
+ ::= { ne843Retire 50 }
+
+ne843RetireCp1Dfa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Distribution Fail"
+ ::= { ne843Retire 51 }
+
+ne843RetireCp1Did NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "ID Conflict"
+ ::= { ne843Retire 52 }
+
+ne843RetireCp1Icc NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Incompatible Converter Alarm"
+ ::= { ne843Retire 53 }
+
+ne843RetireCp1Mfa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Multiple Converter Fail"
+ ::= { ne843Retire 54 }
+
+ne843RetireCp1Hva NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter High Voltage Major"
+ ::= { ne843Retire 55 }
+
+ne843RetireCp1Hfv NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter High Voltage Minor"
+ ::= { ne843Retire 56 }
+
+ne843RetireCp1Vla NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter Very Low Voltage"
+ ::= { ne843Retire 57 }
+
+ne843RetireCp1Rl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter Redundancy Loss"
+ ::= { ne843Retire 58 }
+
+ne843RetireBr1Bta NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Battery Test Active"
+ ::= { ne843Retire 59 }
+
+ne843RetireBr1Bfa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Battery Test Failed"
+ ::= { ne843Retire 60 }
+
+ne843RetireBr1Scda NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Shorted Cell Detected"
+ ::= { ne843Retire 61 }
+
+ne843RetireBr1Isda NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Imminent Shutdown"
+ ::= { ne843Retire 62 }
+
+ne843RetireBr1Mdp NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Voltage Duplicate ID"
+ ::= { ne843Retire 63 }
+
+ne843RetireBr1Mzd NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Voltage ID Not Configured"
+ ::= { ne843Retire 64 }
+
+ne843RetireBr1Btha NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "High Battery Temperature"
+ ::= { ne843Retire 65 }
+
+ne843RetireCn1Cno NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Open"
+ ::= { ne843Retire 66 }
+
+ne843RetireCn1Cnf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Failed"
+ ::= { ne843Retire 67 }
+
+ne843RetireCn2Cno NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Open"
+ ::= { ne843Retire 68 }
+
+ne843RetireCn2Cnf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Failed"
+ ::= { ne843Retire 69 }
+
+ne843RetireCn3Cno NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Open"
+ ::= { ne843Retire 70 }
+
+ne843RetireCn3Cnf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Failed"
+ ::= { ne843Retire 71 }
+
+ne843RetireCn4Cno NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Open"
+ ::= { ne843Retire 72 }
+
+ne843RetireCn4Cnf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Contactor Failed"
+ ::= { ne843Retire 73 }
+
+ne843RetireCm1Cof NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Queue Overflow"
+ ::= { ne843Retire 74 }
+
+ne843RetireCm1Cor NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Number Did Not Respond"
+ ::= { ne843Retire 75 }
+
+ne843RetireCm1Nnc NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Number Not Configured"
+ ::= { ne843Retire 76 }
+
+ne843RetirePo1Por NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Number Did Not Respond"
+ ::= { ne843Retire 77 }
+
+ne843RetireRp1Rf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Ringer Minor Fail"
+ ::= { ne843Retire 78 }
+
+ne843RetireRp1Rpff NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Ringer Fan Fail"
+ ::= { ne843Retire 79 }
+
+ne843RetireRp1Rprl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Ringer Redundancy Loss"
+ ::= { ne843Retire 80 }
+
+ne843RetireRp1Rpfj NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Ringer Major Fail"
+ ::= { ne843Retire 81 }
+
+ne843RetireRp1Rpxj NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Ringer Major External Fault"
+ ::= { ne843Retire 82 }
+
+ne843RetireRp1Rpxn NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Ringer Minor External Fault"
+ ::= { ne843Retire 83 }
+
+ne843RetireRp1Rcdp NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Ringer ID Conflict"
+ ::= { ne843Retire 84 }
+
+ne843RetireUserDefined NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "This may be a user defined event, or a new controller event."
+ ::= { ne843Retire 85 }
+
+ne843RetireDc1Emd NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Energy Management Disabled"
+ ::= { ne843Retire 86 }
+
+ne843RetireDc1Pfs NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Thermal Probe Fail Safe"
+ ::= { ne843Retire 87 }
+
+ne843RetireDc1Rif NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Rectifier Internal Fault"
+ ::= { ne843Retire 88 }
+
+ne843RetireDc1Lsf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Load Share Fail"
+ ::= { ne843Retire 89 }
+
+ne843RetirePs1Ax7 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 7"
+ ::= { ne843Retire 90 }
+
+ne843RetirePs1Ax8 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 8"
+ ::= { ne843Retire 91 }
+
+ne843RetirePs1Ax9 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 9"
+ ::= { ne843Retire 92 }
+
+ne843RetirePs1Ax10 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 10"
+ ::= { ne843Retire 93 }
+
+ne843RetirePs1Ax11 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 11"
+ ::= { ne843Retire 94 }
+
+ne843RetirePs1Ax12 NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Auxiliary Event 12"
+ ::= { ne843Retire 95 }
+
+ne843RetireBr1Btla NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Low Battery Temperature"
+ ::= { ne843Retire 96 }
+
+ne843RetireBr1Btvh NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Very High Battery Temperature"
+ ::= { ne843Retire 97 }
+
+ne843RetireBr1Btvl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Very Low Battery Temperature"
+ ::= { ne843Retire 98 }
+
+ne843RetireGn1Gnr NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Generator Running"
+ ::= { ne843Retire 99 }
+
+ne843RetireGn1Gnm NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Generator Maintenance Required"
+ ::= { ne843Retire 100 }
+
+ne843RetireGn1Gnf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Generator Fail"
+ ::= { ne843Retire 101 }
+
+ne843RetirePs1Amtl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Low Ambient Temperature"
+ ::= { ne843Retire 102 }
+
+ne843RetirePs1Amth NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "High Ambient Temperature"
+ ::= { ne843Retire 103 }
+
+ne843RetireAco1Aac NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "ACO Active"
+ ::= { ne843Retire 104 }
+
+ne843RetireBr1Rba NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Reverse Battery"
+ ::= { ne843Retire 105 }
+
+ne843RetireCp1Cin NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Converter Input Fail"
+ ::= { ne843Retire 106 }
+
+ne843RetireDc1Bof NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Rectifier ORing FET Fault"
+ ::= { ne843Retire 107 }
+
+ne843RetireDc1Sof NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Rectifier Shorted ORing FET"
+ ::= { ne843Retire 108 }
+
+ne843RetireDc1Der NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Rectifier Under Voltage"
+ ::= { ne843Retire 109 }
+
+ne843RetireGn1Gns NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Generator Start"
+ ::= { ne843Retire 110 }
+
+ne843RetireIvp1Ilvi NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter Low Input"
+ ::= { ne843Retire 111 }
+
+ne843RetireIvp1Ihvi NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter High Input"
+ ::= { ne843Retire 112 }
+
+ne843RetireIvp1Ita NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter High Temperature"
+ ::= { ne843Retire 113 }
+
+ne843RetireIvp1If NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter Fail"
+ ::= { ne843Retire 114 }
+
+ne843RetireIvp1Ilv NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter Low Output"
+ ::= { ne843Retire 115 }
+
+ne843RetireIvp1Ifa NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter Frequency Lock"
+ ::= { ne843Retire 116 }
+
+ne843RetireIvp1Ihv NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter High Output"
+ ::= { ne843Retire 117 }
+
+ne843RetireIvp1Ida NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter Distribution Alarm"
+ ::= { ne843Retire 118 }
+
+ne843RetireIvp1Iof NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter Output Fuse"
+ ::= { ne843Retire 119 }
+
+ne843RetireIvp1Idid NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter ID Conflict"
+ ::= { ne843Retire 120 }
+
+ne843RetireIvp1Iirm NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter High RMS Current"
+ ::= { ne843Retire 121 }
+
+ne843RetireIvp1Iipk NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter High Peak Current"
+ ::= { ne843Retire 122 }
+
+ne843RetireIvp1Icf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter High Crest Factor"
+ ::= { ne843Retire 123 }
+
+ne843RetireIvp1Mif NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Multiple Inverter Fail"
+ ::= { ne843Retire 124 }
+
+ne843RetireIvp1Irls NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Inverter Redundancy Loss"
+ ::= { ne843Retire 125 }
+
+ne843RetireDc1Pmf NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Probe Minimum Fail"
+ ::= { ne843Retire 126 }
+
+ne843RetirePs1Crt NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Configuration Changed Reboot Required"
+ ::= { ne843Retire 127 }
+
+ne843RetireIvp1Milv NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Multiple Inverter Low Input Voltage"
+ ::= { ne843Retire 128 }
+
+ne843RetireDc1Faja NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Distribution Fuse A"
+ ::= { ne843Retire 129 }
+
+ne843RetireDc1Buht NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Bus Hi Temp"
+ ::= { ne843Retire 130 }
+
+ne843RetireDc1Buvht NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Bus Very Hi Temp"
+ ::= { ne843Retire 131 }
+
+ne843RetireDc1Btha NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Batt Hi Temp"
+ ::= { ne843Retire 132 }
+
+ne843RetireDc1Btvh NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Batt Very Hi Temp"
+ ::= { ne843Retire 133 }
+
+ne843RetireDc1Btla NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Batt Low Temp"
+ ::= { ne843Retire 134 }
+
+ne843RetireDc1Btvl NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Batt Very Low Temp"
+ ::= { ne843Retire 135 }
+
+ne843RetireDc1Laht NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Local Amb. Hi Temp"
+ ::= { ne843Retire 136 }
+
+ne843RetireDc1Lalt NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Local Amb. Low Temp"
+ ::= { ne843Retire 137 }
+
+ne843RetireDc1Raht NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Remote Amb. Hi Temp"
+ ::= { ne843Retire 138 }
+
+ne843RetireDc1Ravht NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Remote Amb. Very Hi Temp"
+ ::= { ne843Retire 139 }
+
+ne843RetireDc1Ralt NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Remote Amb. Low Temp"
+ ::= { ne843Retire 140 }
+
+ne843RetireDc1Vlva NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "VA Power Loss"
+ ::= { ne843Retire 141 }
+
+ne843RetireDc1Vlvb NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "VB Power Loss"
+ ::= { ne843Retire 142 }
+
+ne843RetireDc1Ovla NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "IA Overload"
+ ::= { ne843Retire 143 }
+
+ne843RetireDc1Ovlb NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "IB Overload"
+ ::= { ne843Retire 144 }
+
+ne843RetireDc1Pcaux NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "PIC Auxiliary"
+ ::= { ne843Retire 145 }
+
+ne843RetireDc1Slot NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "PIC Slot"
+ ::= { ne843Retire 146 }
+
+ne843RetireDc1Fajb NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Distribution Fuse B"
+ ::= { ne843Retire 147 }
+
+ne843RetireDc1Smw NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Shunt Mis-wired"
+ ::= { ne843Retire 148 }
+
+ne843RetireDc1Cca NOTIFICATION-TYPE
+OBJECTS { ne843TrapDesc, ne843TrapSev, ne843TrapTime, ne843TrapDate, ne843TrapPath }
+STATUS current
+DESCRIPTION
+ "Circuit Assignment"
+ ::= { ne843Retire 149 }
+
+--
+-- object ne843Acd1
+--
+
+ne843Acd1 OBJECT IDENTIFIER ::= { ne843 38 }
+
+ne843Acd1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Acd1 1 }
+
+ne843Acd1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Acd1 2 }
+
+ne843Acd1Brc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Board Code"
+ ::= { ne843Acd1 3 }
+
+ne843Acd1Sn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Serial Number"
+ ::= { ne843Acd1 4 }
+
+ne843Acd1Prd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Phase 1 Description"
+ ::= { ne843Acd1 5 }
+
+ne843Acd1Psd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Phase 2 Description"
+ ::= { ne843Acd1 6 }
+
+ne843Acd1Ptd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Phase 3 Description"
+ ::= { ne843Acd1 7 }
+
+ne843Acd1Prv OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "Vrms"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Phase 1 Voltage (Vrms)"
+ ::= { ne843Acd1 8 }
+
+ne843Acd1Psv OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "Vrms"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Phase 2 Voltage (Vrms)"
+ ::= { ne843Acd1 9 }
+
+ne843Acd1Ptv OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "Vrms"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Phase 3 Voltage (Vrms)"
+ ::= { ne843Acd1 10 }
+
+ne843Acd1Pra OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Phase 1 Current (Amps)"
+ ::= { ne843Acd1 11 }
+
+ne843Acd1Psa OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Phase 2 Current (Amps)"
+ ::= { ne843Acd1 12 }
+
+ne843Acd1Pta OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Phase 3 Current (Amps)"
+ ::= { ne843Acd1 13 }
+
+ne843Acd1Prf OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "Hz"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Phase 1 Frequency (Hz)"
+ ::= { ne843Acd1 14 }
+
+ne843Acd1Psf OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "Hz"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Phase 2 Frequency (Hz)"
+ ::= { ne843Acd1 15 }
+
+ne843Acd1Ptf OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "Hz"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Phase 3 Frequency (Hz)"
+ ::= { ne843Acd1 16 }
+
+ne843Acd1Prk OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "kW"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Phase 1 Power (kW)"
+ ::= { ne843Acd1 17 }
+
+ne843Acd1Psk OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "kW"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Phase 2 Power (kW)"
+ ::= { ne843Acd1 18 }
+
+ne843Acd1Ptk OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "kW"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Phase 3 Power (kW)"
+ ::= { ne843Acd1 19 }
+
+ne843Acd1Syk OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "kW"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Total Power (kW)"
+ ::= { ne843Acd1 20 }
+
+ne843Acd1Prx OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Phase 1 CTR"
+ ::= { ne843Acd1 21 }
+
+ne843Acd1Psx OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Phase 2 CTR"
+ ::= { ne843Acd1 22 }
+
+ne843Acd1Ptx OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Phase 3 CTR"
+ ::= { ne843Acd1 23 }
+
+
+--
+-- object ne843Gn1
+--
+
+ne843Gn1 OBJECT IDENTIFIER ::= { ne843 39 }
+
+ne843Gn1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Gn1 1 }
+
+ne843Gn1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Gn1 2 }
+
+ne843Gn1Rt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Cumulative Runtime"
+ ::= { ne843Gn1 3 }
+
+ne843Gn1Trt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Current Runtime"
+ ::= { ne843Gn1 4 }
+
+ne843Gn1Gnr OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Generator Running
+Value:
+Alarm report from GNR1
+"
+ ::= { ne843Gn1 5 }
+
+ne843Gn1Gnm OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Generator Maintenance Required
+Value:
+Alarm report from GNM1
+"
+ ::= { ne843Gn1 6 }
+
+ne843Gn1Gnf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Generator Fail
+Value:
+Alarm report from GNF1
+"
+ ::= { ne843Gn1 7 }
+
+ne843Gn1Clt OBJECT-TYPE
+SYNTAX Integer32(5..1000)
+UNITS "Amps"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Current Limit Threshold (Amps)"
+ ::= { ne843Gn1 8 }
+
+ne843Gn1Tv OBJECT-TYPE
+SYNTAX Integer32(19..28|40..56)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Start Voltage"
+ ::= { ne843Gn1 9 }
+
+ne843Gn1Tvd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Start Voltage Delay"
+ ::= { ne843Gn1 10 }
+
+ne843Gn1Tp OBJECT-TYPE
+SYNTAX Integer32(10..100)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Start Percent of Charge"
+ ::= { ne843Gn1 11 }
+
+ne843Gn1Tpd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Start POC Delay"
+ ::= { ne843Gn1 12 }
+
+ne843Gn1Tct OBJECT-TYPE
+SYNTAX Integer32
+UNITS "ambient"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Start Cooling (ambient) Temperature (C)"
+ ::= { ne843Gn1 13 }
+
+ne843Gn1Tctd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Start Cooling Temperature Delay"
+ ::= { ne843Gn1 14 }
+
+ne843Gn1Tht OBJECT-TYPE
+SYNTAX Integer32
+UNITS "ambient"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Start Heating (ambient) Temperature (C)"
+ ::= { ne843Gn1 15 }
+
+ne843Gn1Thtd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Start Heating Temperature Delay"
+ ::= { ne843Gn1 16 }
+
+ne843Gn1Pv OBJECT-TYPE
+SYNTAX Integer32(21..30|46..60)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Voltage"
+ ::= { ne843Gn1 17 }
+
+ne843Gn1Pvd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Voltage Delay"
+ ::= { ne843Gn1 18 }
+
+ne843Gn1Pi OBJECT-TYPE
+SYNTAX Integer32(2..50)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Current"
+ ::= { ne843Gn1 19 }
+
+ne843Gn1Pid OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Current Delay"
+ ::= { ne843Gn1 20 }
+
+ne843Gn1Pp OBJECT-TYPE
+SYNTAX Integer32(10..100)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Percent of Charge"
+ ::= { ne843Gn1 21 }
+
+ne843Gn1Ppd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop POC Delay"
+ ::= { ne843Gn1 22 }
+
+ne843Gn1Pct OBJECT-TYPE
+SYNTAX Integer32
+UNITS "ambient"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Cooling (ambient) Temperature (C)"
+ ::= { ne843Gn1 23 }
+
+ne843Gn1Pctd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Cooling Temperature Delay"
+ ::= { ne843Gn1 24 }
+
+ne843Gn1Pht OBJECT-TYPE
+SYNTAX Integer32
+UNITS "ambient"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Heating (ambient) Temperature (C)"
+ ::= { ne843Gn1 25 }
+
+ne843Gn1Phtd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Heating Temperature Delay"
+ ::= { ne843Gn1 26 }
+
+ne843Gn1Mrt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Mininum Run Time"
+ ::= { ne843Gn1 27 }
+
+ne843Gn1Tve OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Start Voltage Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Gn1 28 }
+
+ne843Gn1Tpe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Start Percent of Charge Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Gn1 29 }
+
+ne843Gn1Cte OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Start Cooling Temperatuer Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Gn1 30 }
+
+ne843Gn1Hte OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Start Heating Temperatuer Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Gn1 31 }
+
+ne843Gn1Pve OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Voltage Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Gn1 32 }
+
+ne843Gn1Pie OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Current Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Gn1 33 }
+
+ne843Gn1Ppe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Stop Percent of Charge Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Gn1 34 }
+
+ne843Gn1Nv OBJECT-TYPE
+SYNTAX Integer32(0..999)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Nominal Output Voltage"
+ ::= { ne843Gn1 35 }
+
+ne843Gn1Nva OBJECT-TYPE
+SYNTAX Integer32(0..999000)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Nominal Output Power"
+ ::= { ne843Gn1 36 }
+
+ne843Gn1Ode OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Manual on Duration Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Gn1 37 }
+
+ne843Gn1Odr OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Manual on Duration"
+ ::= { ne843Gn1 38 }
+
+ne843Gn1Ocd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Manual on Duration countdown"
+ ::= { ne843Gn1 39 }
+
+ne843Gn1Gns OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Generator Start
+Value:
+Alarm report from GNS1
+"
+ ::= { ne843Gn1 40 }
+
+ne843Gn1Aue OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Auto Mode Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Gn1 41 }
+
+ne843Gn1Mod OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Auto Mode
+Values:
+OFF,
+ON,
+AUTO
+"
+ ::= { ne843Gn1 42 }
+
+ne843Gn1Stt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"State"
+ ::= { ne843Gn1 43 }
+
+
+--
+-- table BAT
+--
+
+ne843BatTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843BatEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Battery Section data"
+ ::= { ne843 40 }
+
+ne843BatEntry OBJECT-TYPE
+SYNTAX Ne843BatEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Battery Section"
+INDEX { ne843BatEntryIndex }
+ ::= { ne843BatTable 1 }
+
+Ne843BatEntry ::= SEQUENCE {
+ne843BatEntryIndex INTEGER,
+ne843BatEntryIde DisplayString,
+ne843BatEntryDes DisplayString,
+ne843BatEntryCon DisplayString,
+ne843BatEntryStt DisplayString,
+ne843BatEntryNst DisplayString,
+ne843BatEntryBty DisplayString,
+ne843BatEntryCap DisplayString,
+ne843BatEntryDat DisplayString,
+ne843BatEntryMpv DisplayString,
+ne843BatEntryAdc DisplayString
+}
+
+ne843BatEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843BatEntry 1 }
+
+ne843BatEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843BatEntry 2 }
+
+ne843BatEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843BatEntry 3 }
+
+ne843BatEntryCon OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Contactor"
+ ::= { ne843BatEntry 4 }
+
+ne843BatEntryStt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"State"
+ ::= { ne843BatEntry 5 }
+
+ne843BatEntryNst OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Number of Strings"
+ ::= { ne843BatEntry 6 }
+
+ne843BatEntryBty OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Battery Type"
+ ::= { ne843BatEntry 7 }
+
+ne843BatEntryCap OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Capacity"
+ ::= { ne843BatEntry 8 }
+
+ne843BatEntryDat OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Install Date"
+ ::= { ne843BatEntry 9 }
+
+ne843BatEntryMpv OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "Volts"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Midtstring Voltage (Volts)"
+ ::= { ne843BatEntry 10 }
+
+ne843BatEntryAdc OBJECT-TYPE
+SYNTAX DisplayString
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Current (Amps)"
+ ::= { ne843BatEntry 11 }
+
+
+
+--
+-- object ne843Eco1
+--
+
+ne843Eco1 OBJECT IDENTIFIER ::= { ne843 41 }
+
+ne843Eco1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Eco1 1 }
+
+ne843Eco1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Eco1 2 }
+
+ne843Eco1Sofs OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Solar Rectifier Offset"
+ ::= { ne843Eco1 3 }
+
+ne843Eco1Ntrd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Normal Rectifier Drain"
+ ::= { ne843Eco1 4 }
+
+ne843Eco1Strd OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Solar Rectifier Drain"
+ ::= { ne843Eco1 5 }
+
+ne843Eco1Nkwh OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Normal kWh"
+ ::= { ne843Eco1 6 }
+
+ne843Eco1Skwh OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Solar kWh"
+ ::= { ne843Eco1 7 }
+
+ne843Eco1Ncap OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Normal Capacity"
+ ::= { ne843Eco1 8 }
+
+ne843Eco1Nocap OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Normal Online Capacity"
+ ::= { ne843Eco1 9 }
+
+
+--
+-- object ne843Ivp1
+--
+
+ne843Ivp1 OBJECT IDENTIFIER ::= { ne843 42 }
+
+ne843Ivp1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Ivp1 1 }
+
+ne843Ivp1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Ivp1 2 }
+
+ne843Ivp1Cap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Total Installed Inverter Capacity (Amps)"
+ ::= { ne843Ivp1 3 }
+
+ne843Ivp1Irm OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"RMS Current"
+ ::= { ne843Ivp1 4 }
+
+ne843Ivp1Vac OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"AC Output voltage"
+ ::= { ne843Ivp1 5 }
+
+ne843Ivp1Adc OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"DC Current"
+ ::= { ne843Ivp1 6 }
+
+ne843Ivp1Vdc OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"DC Voltage"
+ ::= { ne843Ivp1 7 }
+
+ne843Ivp1Frq OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Frequency"
+ ::= { ne843Ivp1 8 }
+
+ne843Ivp1Lst OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Load Share Target Percentage"
+ ::= { ne843Ivp1 9 }
+
+ne843Ivp1Ste OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Standby Enabled
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Ivp1 10 }
+
+ne843Ivp1Rlse OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Redundancy Loss Enabled
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Ivp1 11 }
+
+ne843Ivp1Dth OBJECT-TYPE
+SYNTAX Integer32(20..25|40..50)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Low Voltage Disconnect Threshold"
+ ::= { ne843Ivp1 12 }
+
+ne843Ivp1Rth OBJECT-TYPE
+SYNTAX Integer32(22..27|44..54)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Low Voltage Reconnect Threshold"
+ ::= { ne843Ivp1 13 }
+
+ne843Ivp1Lvd OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Low Voltage Disconnect Enabled
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Ivp1 14 }
+
+ne843Ivp1Hce OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Hi Crest Factor Enabled
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Ivp1 15 }
+
+ne843Ivp1Hipe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Hi IPeak Current Enabled
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Ivp1 16 }
+
+ne843Ivp1Hrme OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Hi IRMS Currrent Enabled
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Ivp1 17 }
+
+ne843Ivp1Ilvi OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter Low Input
+Value:
+Alarm report from ILVI1
+"
+ ::= { ne843Ivp1 18 }
+
+ne843Ivp1Ihvi OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter High Input
+Value:
+Alarm report from IHVI1
+"
+ ::= { ne843Ivp1 19 }
+
+ne843Ivp1Ita OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter High Temperature
+Value:
+Alarm report from ITA1
+"
+ ::= { ne843Ivp1 20 }
+
+ne843Ivp1If OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter Fail
+Value:
+Alarm report from IF1
+"
+ ::= { ne843Ivp1 21 }
+
+ne843Ivp1Ilv OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter Low Output
+Value:
+Alarm report from ILV1
+"
+ ::= { ne843Ivp1 22 }
+
+ne843Ivp1Ifa OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter Frequency Lock
+Value:
+Alarm report from IFA1
+"
+ ::= { ne843Ivp1 23 }
+
+ne843Ivp1Ihv OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter High Output
+Value:
+Alarm report from IHV1
+"
+ ::= { ne843Ivp1 24 }
+
+ne843Ivp1Ida OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter Distribution Alarm
+Value:
+Alarm report from IDA1
+"
+ ::= { ne843Ivp1 25 }
+
+ne843Ivp1Iof OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter Output Fuse
+Value:
+Alarm report from IOF1
+"
+ ::= { ne843Ivp1 26 }
+
+ne843Ivp1Idid OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter ID Conflict
+Value:
+Alarm report from IDID1
+"
+ ::= { ne843Ivp1 27 }
+
+ne843Ivp1Iirm OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter High RMS Current
+Value:
+Alarm report from IIRM1
+"
+ ::= { ne843Ivp1 28 }
+
+ne843Ivp1Iipk OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter High Peak Current
+Value:
+Alarm report from IIPK1
+"
+ ::= { ne843Ivp1 29 }
+
+ne843Ivp1Icf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter High Crest Factor
+Value:
+Alarm report from ICF1
+"
+ ::= { ne843Ivp1 30 }
+
+ne843Ivp1Mif OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Multiple Inverter Fail
+Value:
+Alarm report from MIF1
+"
+ ::= { ne843Ivp1 31 }
+
+ne843Ivp1Irls OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter Redundancy Loss
+Value:
+Alarm report from IRLS1
+"
+ ::= { ne843Ivp1 32 }
+
+ne843Ivp1Milv OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Multiple Inverter Low Input Voltage
+Value:
+Alarm report from MILV1
+"
+ ::= { ne843Ivp1 33 }
+
+
+--
+-- table INV
+--
+
+ne843InvTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843InvEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Inverter data"
+ ::= { ne843 43 }
+
+ne843InvEntry OBJECT-TYPE
+SYNTAX Ne843InvEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Inverter"
+INDEX { ne843InvEntryIndex }
+ ::= { ne843InvTable 1 }
+
+Ne843InvEntry ::= SEQUENCE {
+ne843InvEntryIndex INTEGER,
+ne843InvEntryIde DisplayString,
+ne843InvEntryDes DisplayString,
+ne843InvEntryTyp DisplayString,
+ne843InvEntrySn DisplayString,
+ne843InvEntryAdc Integer32,
+ne843InvEntryVdc Integer32,
+ne843InvEntryVac Integer32,
+ne843InvEntryStt DisplayString,
+ne843InvEntryCap Integer32,
+ne843InvEntryCva Integer32,
+ne843InvEntryIpk Integer32,
+ne843InvEntryIrm Integer32,
+ne843InvEntryFrq Integer32,
+ne843InvEntryCf Integer32,
+ne843InvEntryPwr Integer32,
+ne843InvEntryVnom Integer32,
+ne843InvEntryNcl INTEGER,
+ne843InvEntryIlvi DisplayString,
+ne843InvEntryIta DisplayString,
+ne843InvEntryIf DisplayString,
+ne843InvEntryIlv DisplayString,
+ne843InvEntryIfa DisplayString,
+ne843InvEntryDid DisplayString,
+ne843InvEntryIcmf DisplayString,
+ne843InvEntryIcf DisplayString,
+ne843InvEntryIda DisplayString,
+ne843InvEntryIhv DisplayString,
+ne843InvEntryIhvi DisplayString,
+ne843InvEntryIipk DisplayString,
+ne843InvEntryIirm DisplayString,
+ne843InvEntryIof DisplayString,
+ne843InvEntryIlvi1 INTEGER,
+ne843InvEntryIta1 INTEGER,
+ne843InvEntryIf1 INTEGER,
+ne843InvEntryIlv1 INTEGER,
+ne843InvEntryIfa1 INTEGER,
+ne843InvEntryDid1 INTEGER,
+ne843InvEntryIcmf1 INTEGER,
+ne843InvEntryIcf1 INTEGER,
+ne843InvEntryIda1 INTEGER,
+ne843InvEntryIhv1 INTEGER,
+ne843InvEntryIhvi1 INTEGER,
+ne843InvEntryIipk1 INTEGER,
+ne843InvEntryIirm1 INTEGER,
+ne843InvEntryIof1 INTEGER
+}
+
+ne843InvEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843InvEntry 1 }
+
+ne843InvEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843InvEntry 2 }
+
+ne843InvEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843InvEntry 3 }
+
+ne843InvEntryTyp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Type"
+ ::= { ne843InvEntry 4 }
+
+ne843InvEntrySn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Serial Number"
+ ::= { ne843InvEntry 5 }
+
+ne843InvEntryAdc OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"DC Current (Amps)"
+ ::= { ne843InvEntry 6 }
+
+ne843InvEntryVdc OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"DC Voltage"
+ ::= { ne843InvEntry 7 }
+
+ne843InvEntryVac OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Volts"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"AC Voltage (Volts)"
+ ::= { ne843InvEntry 8 }
+
+ne843InvEntryStt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"State
+Values:
+ON,
+OFF,
+STANDBY,
+VACANT
+"
+ ::= { ne843InvEntry 9 }
+
+ne843InvEntryCap OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Capacity (Amps)"
+ ::= { ne843InvEntry 10 }
+
+ne843InvEntryCva OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Capacity in VA"
+ ::= { ne843InvEntry 11 }
+
+ne843InvEntryIpk OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Peak Current"
+ ::= { ne843InvEntry 12 }
+
+ne843InvEntryIrm OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"RMS Current"
+ ::= { ne843InvEntry 13 }
+
+ne843InvEntryFrq OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Output Frequency"
+ ::= { ne843InvEntry 14 }
+
+ne843InvEntryCf OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Crest Factor"
+ ::= { ne843InvEntry 15 }
+
+ne843InvEntryPwr OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Output Power"
+ ::= { ne843InvEntry 16 }
+
+ne843InvEntryVnom OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Nominal Output Voltage"
+ ::= { ne843InvEntry 17 }
+
+ne843InvEntryNcl OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+UNITS "for LVD"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Non-Critical Load (for LVD)
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843InvEntry 18 }
+
+ne843InvEntryIlvi OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Low Voltage Input"
+ ::= { ne843InvEntry 19 }
+
+ne843InvEntryIta OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Temperature Alarm"
+ ::= { ne843InvEntry 20 }
+
+ne843InvEntryIf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter Fail"
+ ::= { ne843InvEntry 21 }
+
+ne843InvEntryIlv OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Low Output Voltage"
+ ::= { ne843InvEntry 22 }
+
+ne843InvEntryIfa OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter Frequency Lock Fail"
+ ::= { ne843InvEntry 23 }
+
+ne843InvEntryDid OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ID Conflict"
+ ::= { ne843InvEntry 24 }
+
+ne843InvEntryIcmf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Communication Failure"
+ ::= { ne843InvEntry 25 }
+
+ne843InvEntryIcf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Hi Crest Factor Status"
+ ::= { ne843InvEntry 26 }
+
+ne843InvEntryIda OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Distribution Alarm Status"
+ ::= { ne843InvEntry 27 }
+
+ne843InvEntryIhv OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"High Output Status"
+ ::= { ne843InvEntry 28 }
+
+ne843InvEntryIhvi OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"High Input Status"
+ ::= { ne843InvEntry 29 }
+
+ne843InvEntryIipk OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"High IPeak Status"
+ ::= { ne843InvEntry 30 }
+
+ne843InvEntryIirm OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"High IRMS Status"
+ ::= { ne843InvEntry 31 }
+
+ne843InvEntryIof OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Output Fuse Status"
+ ::= { ne843InvEntry 32 }
+
+ne843InvEntryIlvi1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Low Voltage Input
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843InvEntry 33 }
+
+ne843InvEntryIta1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Temperature Alarm
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843InvEntry 34 }
+
+ne843InvEntryIf1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter Fail
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843InvEntry 35 }
+
+ne843InvEntryIlv1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Low Output Voltage
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843InvEntry 36 }
+
+ne843InvEntryIfa1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Inverter Frequency Lock Fail
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843InvEntry 37 }
+
+ne843InvEntryDid1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ID Conflict
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843InvEntry 38 }
+
+ne843InvEntryIcmf1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Communication Failure
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843InvEntry 39 }
+
+ne843InvEntryIcf1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Hi Crest Factor Status
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843InvEntry 40 }
+
+ne843InvEntryIda1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Distribution Alarm Status
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843InvEntry 41 }
+
+ne843InvEntryIhv1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"High Output Status
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843InvEntry 42 }
+
+ne843InvEntryIhvi1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"High Input Status
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843InvEntry 43 }
+
+ne843InvEntryIipk1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"High IPeak Status
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843InvEntry 44 }
+
+ne843InvEntryIirm1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"High IRMS Status
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843InvEntry 45 }
+
+ne843InvEntryIof1 OBJECT-TYPE
+SYNTAX INTEGER {
+inactive(0),
+active(1)
+}
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Output Fuse Status
+Values:
+inactive(0),
+active(1)
+"
+ ::= { ne843InvEntry 46 }
+
+
+
+--
+-- object ne843Rpt1
+--
+
+ne843Rpt1 OBJECT IDENTIFIER ::= { ne843 44 }
+
+ne843Rpt1Ide OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843Rpt1 1 }
+
+ne843Rpt1Des OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843Rpt1 2 }
+
+ne843Rpt1Ena OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843Rpt1 3 }
+
+ne843Rpt1Int OBJECT-TYPE
+SYNTAX Integer32(1..60)
+UNITS "minutes"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Interval (minutes)"
+ ::= { ne843Rpt1 4 }
+
+ne843Rpt1D001 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 1"
+ ::= { ne843Rpt1 5 }
+
+ne843Rpt1D002 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 2"
+ ::= { ne843Rpt1 6 }
+
+ne843Rpt1D003 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 3"
+ ::= { ne843Rpt1 7 }
+
+ne843Rpt1D004 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 4"
+ ::= { ne843Rpt1 8 }
+
+ne843Rpt1D005 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 5"
+ ::= { ne843Rpt1 9 }
+
+ne843Rpt1D006 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 6"
+ ::= { ne843Rpt1 10 }
+
+ne843Rpt1D007 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 7"
+ ::= { ne843Rpt1 11 }
+
+ne843Rpt1D008 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 8"
+ ::= { ne843Rpt1 12 }
+
+ne843Rpt1D009 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 9"
+ ::= { ne843Rpt1 13 }
+
+ne843Rpt1D010 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 10"
+ ::= { ne843Rpt1 14 }
+
+ne843Rpt1D011 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 11"
+ ::= { ne843Rpt1 15 }
+
+ne843Rpt1D012 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 12"
+ ::= { ne843Rpt1 16 }
+
+ne843Rpt1D013 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 13"
+ ::= { ne843Rpt1 17 }
+
+ne843Rpt1D014 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 14"
+ ::= { ne843Rpt1 18 }
+
+ne843Rpt1D015 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 15"
+ ::= { ne843Rpt1 19 }
+
+ne843Rpt1D016 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 16"
+ ::= { ne843Rpt1 20 }
+
+ne843Rpt1D017 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 17"
+ ::= { ne843Rpt1 21 }
+
+ne843Rpt1D018 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 18"
+ ::= { ne843Rpt1 22 }
+
+ne843Rpt1D019 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 19"
+ ::= { ne843Rpt1 23 }
+
+ne843Rpt1D020 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 20"
+ ::= { ne843Rpt1 24 }
+
+ne843Rpt1D021 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 21"
+ ::= { ne843Rpt1 25 }
+
+ne843Rpt1D022 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 22"
+ ::= { ne843Rpt1 26 }
+
+ne843Rpt1D023 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 23"
+ ::= { ne843Rpt1 27 }
+
+ne843Rpt1D024 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 24"
+ ::= { ne843Rpt1 28 }
+
+ne843Rpt1D025 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 25"
+ ::= { ne843Rpt1 29 }
+
+ne843Rpt1D026 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 26"
+ ::= { ne843Rpt1 30 }
+
+ne843Rpt1D027 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 27"
+ ::= { ne843Rpt1 31 }
+
+ne843Rpt1D028 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 28"
+ ::= { ne843Rpt1 32 }
+
+ne843Rpt1D029 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 29"
+ ::= { ne843Rpt1 33 }
+
+ne843Rpt1D030 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 30"
+ ::= { ne843Rpt1 34 }
+
+ne843Rpt1D031 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 31"
+ ::= { ne843Rpt1 35 }
+
+ne843Rpt1D032 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 32"
+ ::= { ne843Rpt1 36 }
+
+ne843Rpt1D033 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 33"
+ ::= { ne843Rpt1 37 }
+
+ne843Rpt1D034 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 34"
+ ::= { ne843Rpt1 38 }
+
+ne843Rpt1D035 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 35"
+ ::= { ne843Rpt1 39 }
+
+ne843Rpt1D036 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 36"
+ ::= { ne843Rpt1 40 }
+
+ne843Rpt1D037 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 37"
+ ::= { ne843Rpt1 41 }
+
+ne843Rpt1D038 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 38"
+ ::= { ne843Rpt1 42 }
+
+ne843Rpt1D039 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 39"
+ ::= { ne843Rpt1 43 }
+
+ne843Rpt1D040 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 40"
+ ::= { ne843Rpt1 44 }
+
+ne843Rpt1D041 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 41"
+ ::= { ne843Rpt1 45 }
+
+ne843Rpt1D042 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 42"
+ ::= { ne843Rpt1 46 }
+
+ne843Rpt1D043 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 43"
+ ::= { ne843Rpt1 47 }
+
+ne843Rpt1D044 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 44"
+ ::= { ne843Rpt1 48 }
+
+ne843Rpt1D045 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 45"
+ ::= { ne843Rpt1 49 }
+
+ne843Rpt1D046 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 46"
+ ::= { ne843Rpt1 50 }
+
+ne843Rpt1D047 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 47"
+ ::= { ne843Rpt1 51 }
+
+ne843Rpt1D048 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 48"
+ ::= { ne843Rpt1 52 }
+
+ne843Rpt1D049 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 49"
+ ::= { ne843Rpt1 53 }
+
+ne843Rpt1D050 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 40"
+ ::= { ne843Rpt1 54 }
+
+ne843Rpt1D051 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 51"
+ ::= { ne843Rpt1 55 }
+
+ne843Rpt1D052 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 52"
+ ::= { ne843Rpt1 56 }
+
+ne843Rpt1D053 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 53"
+ ::= { ne843Rpt1 57 }
+
+ne843Rpt1D054 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 54"
+ ::= { ne843Rpt1 58 }
+
+ne843Rpt1D055 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 55"
+ ::= { ne843Rpt1 59 }
+
+ne843Rpt1D056 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 56"
+ ::= { ne843Rpt1 60 }
+
+ne843Rpt1D057 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 57"
+ ::= { ne843Rpt1 61 }
+
+ne843Rpt1D058 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 58"
+ ::= { ne843Rpt1 62 }
+
+ne843Rpt1D059 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 59"
+ ::= { ne843Rpt1 63 }
+
+ne843Rpt1D060 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 60"
+ ::= { ne843Rpt1 64 }
+
+ne843Rpt1D061 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 61"
+ ::= { ne843Rpt1 65 }
+
+ne843Rpt1D062 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 62"
+ ::= { ne843Rpt1 66 }
+
+ne843Rpt1D063 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 63"
+ ::= { ne843Rpt1 67 }
+
+ne843Rpt1D064 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 64"
+ ::= { ne843Rpt1 68 }
+
+ne843Rpt1D065 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 65"
+ ::= { ne843Rpt1 69 }
+
+ne843Rpt1D066 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 66"
+ ::= { ne843Rpt1 70 }
+
+ne843Rpt1D067 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 67"
+ ::= { ne843Rpt1 71 }
+
+ne843Rpt1D068 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 68"
+ ::= { ne843Rpt1 72 }
+
+ne843Rpt1D069 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 69"
+ ::= { ne843Rpt1 73 }
+
+ne843Rpt1D070 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 70"
+ ::= { ne843Rpt1 74 }
+
+ne843Rpt1D071 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 71"
+ ::= { ne843Rpt1 75 }
+
+ne843Rpt1D072 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 72"
+ ::= { ne843Rpt1 76 }
+
+ne843Rpt1D073 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 73"
+ ::= { ne843Rpt1 77 }
+
+ne843Rpt1D074 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 74"
+ ::= { ne843Rpt1 78 }
+
+ne843Rpt1D075 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 75"
+ ::= { ne843Rpt1 79 }
+
+ne843Rpt1D076 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 76"
+ ::= { ne843Rpt1 80 }
+
+ne843Rpt1D077 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 77"
+ ::= { ne843Rpt1 81 }
+
+ne843Rpt1D078 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 78"
+ ::= { ne843Rpt1 82 }
+
+ne843Rpt1D079 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 79"
+ ::= { ne843Rpt1 83 }
+
+ne843Rpt1D080 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 80"
+ ::= { ne843Rpt1 84 }
+
+ne843Rpt1D081 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 81"
+ ::= { ne843Rpt1 85 }
+
+ne843Rpt1D082 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 82"
+ ::= { ne843Rpt1 86 }
+
+ne843Rpt1D083 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 83"
+ ::= { ne843Rpt1 87 }
+
+ne843Rpt1D084 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 84"
+ ::= { ne843Rpt1 88 }
+
+ne843Rpt1D085 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 85"
+ ::= { ne843Rpt1 89 }
+
+ne843Rpt1D086 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 86"
+ ::= { ne843Rpt1 90 }
+
+ne843Rpt1D087 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 87"
+ ::= { ne843Rpt1 91 }
+
+ne843Rpt1D088 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 88"
+ ::= { ne843Rpt1 92 }
+
+ne843Rpt1D089 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 89"
+ ::= { ne843Rpt1 93 }
+
+ne843Rpt1D090 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 90"
+ ::= { ne843Rpt1 94 }
+
+ne843Rpt1D091 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 91"
+ ::= { ne843Rpt1 95 }
+
+ne843Rpt1D092 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 92"
+ ::= { ne843Rpt1 96 }
+
+ne843Rpt1D093 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 93"
+ ::= { ne843Rpt1 97 }
+
+ne843Rpt1D094 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 94"
+ ::= { ne843Rpt1 98 }
+
+ne843Rpt1D095 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 95"
+ ::= { ne843Rpt1 99 }
+
+ne843Rpt1D096 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 96"
+ ::= { ne843Rpt1 100 }
+
+ne843Rpt1D097 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 97"
+ ::= { ne843Rpt1 101 }
+
+ne843Rpt1D098 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 98"
+ ::= { ne843Rpt1 102 }
+
+ne843Rpt1D099 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 99"
+ ::= { ne843Rpt1 103 }
+
+ne843Rpt1D100 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 100"
+ ::= { ne843Rpt1 104 }
+
+ne843Rpt1D101 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 101"
+ ::= { ne843Rpt1 105 }
+
+ne843Rpt1D102 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 102"
+ ::= { ne843Rpt1 106 }
+
+ne843Rpt1D103 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 103"
+ ::= { ne843Rpt1 107 }
+
+ne843Rpt1D104 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 104"
+ ::= { ne843Rpt1 108 }
+
+ne843Rpt1D105 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 105"
+ ::= { ne843Rpt1 109 }
+
+ne843Rpt1D106 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 106"
+ ::= { ne843Rpt1 110 }
+
+ne843Rpt1D107 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 107"
+ ::= { ne843Rpt1 111 }
+
+ne843Rpt1D108 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 108"
+ ::= { ne843Rpt1 112 }
+
+ne843Rpt1D109 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 109"
+ ::= { ne843Rpt1 113 }
+
+ne843Rpt1D110 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 110"
+ ::= { ne843Rpt1 114 }
+
+ne843Rpt1D111 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 111"
+ ::= { ne843Rpt1 115 }
+
+ne843Rpt1D112 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 112"
+ ::= { ne843Rpt1 116 }
+
+ne843Rpt1D113 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 113"
+ ::= { ne843Rpt1 117 }
+
+ne843Rpt1D114 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 114"
+ ::= { ne843Rpt1 118 }
+
+ne843Rpt1D115 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 115"
+ ::= { ne843Rpt1 119 }
+
+ne843Rpt1D116 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 116"
+ ::= { ne843Rpt1 120 }
+
+ne843Rpt1D117 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 117"
+ ::= { ne843Rpt1 121 }
+
+ne843Rpt1D118 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 118"
+ ::= { ne843Rpt1 122 }
+
+ne843Rpt1D119 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 119"
+ ::= { ne843Rpt1 123 }
+
+ne843Rpt1D120 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 120"
+ ::= { ne843Rpt1 124 }
+
+ne843Rpt1D121 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 121"
+ ::= { ne843Rpt1 125 }
+
+ne843Rpt1D122 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 122"
+ ::= { ne843Rpt1 126 }
+
+ne843Rpt1D123 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 123"
+ ::= { ne843Rpt1 127 }
+
+ne843Rpt1D124 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 124"
+ ::= { ne843Rpt1 128 }
+
+ne843Rpt1D125 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 125"
+ ::= { ne843Rpt1 129 }
+
+ne843Rpt1D126 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 126"
+ ::= { ne843Rpt1 130 }
+
+ne843Rpt1D127 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 127"
+ ::= { ne843Rpt1 131 }
+
+ne843Rpt1D128 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 128"
+ ::= { ne843Rpt1 132 }
+
+ne843Rpt1D129 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 129"
+ ::= { ne843Rpt1 133 }
+
+ne843Rpt1D130 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 130"
+ ::= { ne843Rpt1 134 }
+
+ne843Rpt1D131 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 131"
+ ::= { ne843Rpt1 135 }
+
+ne843Rpt1D132 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 132"
+ ::= { ne843Rpt1 136 }
+
+ne843Rpt1D133 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 133"
+ ::= { ne843Rpt1 137 }
+
+ne843Rpt1D134 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 134"
+ ::= { ne843Rpt1 138 }
+
+ne843Rpt1D135 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 135"
+ ::= { ne843Rpt1 139 }
+
+ne843Rpt1D136 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 136"
+ ::= { ne843Rpt1 140 }
+
+ne843Rpt1D137 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 137"
+ ::= { ne843Rpt1 141 }
+
+ne843Rpt1D138 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 138"
+ ::= { ne843Rpt1 142 }
+
+ne843Rpt1D139 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 139"
+ ::= { ne843Rpt1 143 }
+
+ne843Rpt1D140 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 140"
+ ::= { ne843Rpt1 144 }
+
+ne843Rpt1D141 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 141"
+ ::= { ne843Rpt1 145 }
+
+ne843Rpt1D142 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 142"
+ ::= { ne843Rpt1 146 }
+
+ne843Rpt1D143 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 143"
+ ::= { ne843Rpt1 147 }
+
+ne843Rpt1D144 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 144"
+ ::= { ne843Rpt1 148 }
+
+ne843Rpt1D145 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 145"
+ ::= { ne843Rpt1 149 }
+
+ne843Rpt1D146 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 146"
+ ::= { ne843Rpt1 150 }
+
+ne843Rpt1D147 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 147"
+ ::= { ne843Rpt1 151 }
+
+ne843Rpt1D148 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 148"
+ ::= { ne843Rpt1 152 }
+
+ne843Rpt1D149 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 149"
+ ::= { ne843Rpt1 153 }
+
+ne843Rpt1D150 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Parameter 150"
+ ::= { ne843Rpt1 154 }
+
+
+--
+-- table PIC
+--
+
+ne843PicTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843PicEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Panel Interface Card data"
+ ::= { ne843 45 }
+
+ne843PicEntry OBJECT-TYPE
+SYNTAX Ne843PicEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Panel Interface Card"
+INDEX { ne843PicEntryIndex }
+ ::= { ne843PicTable 1 }
+
+Ne843PicEntry ::= SEQUENCE {
+ne843PicEntryIndex INTEGER,
+ne843PicEntryIde DisplayString,
+ne843PicEntryDes DisplayString,
+ne843PicEntrySn DisplayString,
+ne843PicEntryCc DisplayString,
+ne843PicEntrySer DisplayString,
+ne843PicEntryClei DisplayString,
+ne843PicEntryCustpn2 DisplayString,
+ne843PicEntryAsstag2 DisplayString,
+ne843PicEntryStt DisplayString,
+ne843PicEntryTyp DisplayString,
+ne843PicEntryNst Integer32,
+ne843PicEntryNvt Integer32,
+ne843PicEntryVera DisplayString,
+ne843PicEntryPid DisplayString,
+ne843PicEntryPcf DisplayString,
+ne843PicEntryNumslot Integer32,
+ne843PicEntryCbf DisplayString,
+ne843PicEntryFajae INTEGER,
+ne843PicEntryFajrly DisplayString,
+ne843PicEntryOsae INTEGER,
+ne843PicEntryOsarly DisplayString,
+ne843PicEntryTmpe INTEGER,
+ne843PicEntryTmprly DisplayString,
+ne843PicEntryVlvs DisplayString,
+ne843PicEntryVlvlat DisplayString,
+ne843PicEntryVlvae INTEGER,
+ne843PicEntryVlvath Integer32,
+ne843PicEntryVlvbe INTEGER,
+ne843PicEntryVlvbth Integer32,
+ne843PicEntryVlvrly DisplayString,
+ne843PicEntryOvls DisplayString,
+ne843PicEntryOlvlat DisplayString,
+ne843PicEntryOvlae INTEGER,
+ne843PicEntryOvlath Integer32,
+ne843PicEntryOvlbe INTEGER,
+ne843PicEntryOvlbth Integer32,
+ne843PicEntryOvlrly DisplayString,
+ne843PicEntryEpoe INTEGER,
+ne843PicEntryEporly DisplayString,
+ne843PicEntryPcauxe INTEGER,
+ne843PicEntryPcauxr DisplayString,
+ne843PicEntrySlote INTEGER,
+ne843PicEntrySlotrly DisplayString,
+ne843PicEntryDpmode DisplayString,
+ne843PicEntryPnldes DisplayString,
+ne843PicEntryMdl DisplayString,
+ne843PicEntryPnlsn DisplayString,
+ne843PicEntryPnlcc DisplayString,
+ne843PicEntryPnlser DisplayString,
+ne843PicEntryPnlclei DisplayString,
+ne843PicEntryCustpn1 DisplayString,
+ne843PicEntryAsstag1 DisplayString,
+ne843PicEntryRtng DisplayString,
+ne843PicEntryPnlsize DisplayString
+}
+
+ne843PicEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843PicEntry 1 }
+
+ne843PicEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843PicEntry 2 }
+
+ne843PicEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843PicEntry 3 }
+
+ne843PicEntrySn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Serial Number"
+ ::= { ne843PicEntry 4 }
+
+ne843PicEntryCc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Comcode"
+ ::= { ne843PicEntry 5 }
+
+ne843PicEntrySer OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Series"
+ ::= { ne843PicEntry 6 }
+
+ne843PicEntryClei OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Clei Code"
+ ::= { ne843PicEntry 7 }
+
+ne843PicEntryCustpn2 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Customer PIC Part Number"
+ ::= { ne843PicEntry 8 }
+
+ne843PicEntryAsstag2 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"PIC Asset Tag"
+ ::= { ne843PicEntry 9 }
+
+ne843PicEntryStt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"State
+Values:
+PRESENT,
+MISSING,
+VACANT
+"
+ ::= { ne843PicEntry 10 }
+
+ne843PicEntryTyp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"PIC Type
+Values:
+LOAD,
+BATT
+"
+ ::= { ne843PicEntry 11 }
+
+ne843PicEntryNst OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Number of Shunts"
+ ::= { ne843PicEntry 12 }
+
+ne843PicEntryNvt OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Number of Voltages"
+ ::= { ne843PicEntry 13 }
+
+ne843PicEntryVera OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Application Software Version"
+ ::= { ne843PicEntry 14 }
+
+ne843PicEntryPid OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"ID Conflict"
+ ::= { ne843PicEntry 15 }
+
+ne843PicEntryPcf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Communication Failure"
+ ::= { ne843PicEntry 16 }
+
+ne843PicEntryNumslot OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Slots"
+ ::= { ne843PicEntry 17 }
+
+ne843PicEntryCbf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"CB or Fuse
+Values:
+CB,
+FUSE
+"
+ ::= { ne843PicEntry 18 }
+
+ne843PicEntryFajae OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"External Fuse Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843PicEntry 19 }
+
+ne843PicEntryFajrly OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"External Fuse Relay
+Values:
+None,
+Enabled
+"
+ ::= { ne843PicEntry 20 }
+
+ne843PicEntryOsae OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Open String Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843PicEntry 21 }
+
+ne843PicEntryOsarly OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Open String Relay
+Values:
+None,
+Enabled
+"
+ ::= { ne843PicEntry 22 }
+
+ne843PicEntryTmpe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Temperature Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843PicEntry 23 }
+
+ne843PicEntryTmprly OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Temperature Relay
+Values:
+None,
+Enabled
+"
+ ::= { ne843PicEntry 24 }
+
+ne843PicEntryVlvs OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Power Loss Severity
+Values:
+CRIT,
+MAJ,
+MIN,
+WRN,
+RO
+"
+ ::= { ne843PicEntry 25 }
+
+ne843PicEntryVlvlat OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Power Loss Latched"
+ ::= { ne843PicEntry 26 }
+
+ne843PicEntryVlvae OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"VA Power Loss Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843PicEntry 27 }
+
+ne843PicEntryVlvath OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"VB Power Loss Threshold"
+ ::= { ne843PicEntry 28 }
+
+ne843PicEntryVlvbe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"VB Power Loss Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843PicEntry 29 }
+
+ne843PicEntryVlvbth OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"VB Power Loss Threshold"
+ ::= { ne843PicEntry 30 }
+
+ne843PicEntryVlvrly OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Power Loss Relay
+Values:
+None,
+Enabled
+"
+ ::= { ne843PicEntry 31 }
+
+ne843PicEntryOvls OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Overload Severity
+Values:
+CRIT,
+MAJ,
+MIN,
+WRN,
+RO
+"
+ ::= { ne843PicEntry 32 }
+
+ne843PicEntryOlvlat OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Overload Latched"
+ ::= { ne843PicEntry 33 }
+
+ne843PicEntryOvlae OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"IA Overload Enabled
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843PicEntry 34 }
+
+ne843PicEntryOvlath OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"IA Overload Threshold"
+ ::= { ne843PicEntry 35 }
+
+ne843PicEntryOvlbe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"IB Overload Enabled
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843PicEntry 36 }
+
+ne843PicEntryOvlbth OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"IB Overload Threshold"
+ ::= { ne843PicEntry 37 }
+
+ne843PicEntryOvlrly OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Overload Relay
+Values:
+None,
+Enabled
+"
+ ::= { ne843PicEntry 38 }
+
+ne843PicEntryEpoe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Emergency Power Off Enabled
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843PicEntry 39 }
+
+ne843PicEntryEporly OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Emergency Power Off Relay
+Values:
+None,
+Enabled
+"
+ ::= { ne843PicEntry 40 }
+
+ne843PicEntryPcauxe OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"PIC Auxiliary Enabled
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843PicEntry 41 }
+
+ne843PicEntryPcauxr OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"PIC Auxiliary Relay
+Values:
+None,
+Enabled
+"
+ ::= { ne843PicEntry 42 }
+
+ne843PicEntrySlote OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Slot Enabled
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843PicEntry 43 }
+
+ne843PicEntrySlotrly OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Slot Relay
+Values:
+None,
+Enabled
+"
+ ::= { ne843PicEntry 44 }
+
+ne843PicEntryDpmode OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Display Mode
+Values:
+SCAN,
+STATIC
+"
+ ::= { ne843PicEntry 45 }
+
+ne843PicEntryPnldes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Panel Description"
+ ::= { ne843PicEntry 46 }
+
+ne843PicEntryMdl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Panel Model"
+ ::= { ne843PicEntry 47 }
+
+ne843PicEntryPnlsn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Panel Serial Number"
+ ::= { ne843PicEntry 48 }
+
+ne843PicEntryPnlcc OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Panel Comcode"
+ ::= { ne843PicEntry 49 }
+
+ne843PicEntryPnlser OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Panel Series"
+ ::= { ne843PicEntry 50 }
+
+ne843PicEntryPnlclei OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Panel Clei Code"
+ ::= { ne843PicEntry 51 }
+
+ne843PicEntryCustpn1 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Panel Customer Part Number"
+ ::= { ne843PicEntry 52 }
+
+ne843PicEntryAsstag1 OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Panel Customer Asset Tag"
+ ::= { ne843PicEntry 53 }
+
+ne843PicEntryRtng OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Panel Rating"
+ ::= { ne843PicEntry 54 }
+
+ne843PicEntryPnlsize OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Panel Size"
+ ::= { ne843PicEntry 55 }
+
+
+
+--
+-- table PCM
+--
+
+ne843PcmTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843PcmEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all PIC Current Monitor data"
+ ::= { ne843 46 }
+
+ne843PcmEntry OBJECT-TYPE
+SYNTAX Ne843PcmEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one PIC Current Monitor"
+INDEX { ne843PcmEntryIndex }
+ ::= { ne843PcmTable 1 }
+
+Ne843PcmEntry ::= SEQUENCE {
+ne843PcmEntryIndex INTEGER,
+ne843PcmEntryIde DisplayString,
+ne843PcmEntryDes DisplayString,
+ne843PcmEntryVal DisplayString,
+ne843PcmEntrySht DisplayString,
+ne843PcmEntrySha Integer32,
+ne843PcmEntryShv Integer32
+}
+
+ne843PcmEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843PcmEntry 1 }
+
+ne843PcmEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843PcmEntry 2 }
+
+ne843PcmEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843PcmEntry 3 }
+
+ne843PcmEntryVal OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Value"
+ ::= { ne843PcmEntry 4 }
+
+ne843PcmEntrySht OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Shunt Type
+Values:
+LOAD,
+BATTERY,
+NONE
+"
+ ::= { ne843PcmEntry 5 }
+
+ne843PcmEntrySha OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Shunt Current"
+ ::= { ne843PcmEntry 6 }
+
+ne843PcmEntryShv OBJECT-TYPE
+SYNTAX Integer32(1..150)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Shunt Voltage"
+ ::= { ne843PcmEntry 7 }
+
+
+
+--
+-- table PVM
+--
+
+ne843PvmTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843PvmEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all PIC Voltage Monitor data"
+ ::= { ne843 47 }
+
+ne843PvmEntry OBJECT-TYPE
+SYNTAX Ne843PvmEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one PIC Voltage Monitor"
+INDEX { ne843PvmEntryIndex }
+ ::= { ne843PvmTable 1 }
+
+Ne843PvmEntry ::= SEQUENCE {
+ne843PvmEntryIndex INTEGER,
+ne843PvmEntryIde DisplayString,
+ne843PvmEntryDes DisplayString,
+ne843PvmEntryVal Integer32
+}
+
+ne843PvmEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843PvmEntry 1 }
+
+ne843PvmEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843PvmEntry 2 }
+
+ne843PvmEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843PvmEntry 3 }
+
+ne843PvmEntryVal OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Value"
+ ::= { ne843PvmEntry 4 }
+
+
+
+--
+-- table PTM
+--
+
+ne843PtmTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843PtmEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all PIC Temperature Monitor data"
+ ::= { ne843 48 }
+
+ne843PtmEntry OBJECT-TYPE
+SYNTAX Ne843PtmEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one PIC Temperature Monitor"
+INDEX { ne843PtmEntryIndex }
+ ::= { ne843PtmTable 1 }
+
+Ne843PtmEntry ::= SEQUENCE {
+ne843PtmEntryIndex INTEGER,
+ne843PtmEntryIde DisplayString,
+ne843PtmEntryDes DisplayString,
+ne843PtmEntryBamt Integer32,
+ne843PtmEntryNat Integer32,
+ne843PtmEntryHamt Integer32,
+ne843PtmEntryLamt Integer32,
+ne843PtmEntryNtm Integer32,
+ne843PtmEntryHbt Integer32,
+ne843PtmEntryLbt Integer32,
+ne843PtmEntryNbut Integer32,
+ne843PtmEntryHbut Integer32,
+ne843PtmEntryLbut Integer32
+}
+
+ne843PtmEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843PtmEntry 1 }
+
+ne843PtmEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843PtmEntry 2 }
+
+ne843PtmEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843PtmEntry 3 }
+
+ne843PtmEntryBamt OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Board Ambient Temperature"
+ ::= { ne843PtmEntry 4 }
+
+ne843PtmEntryNat OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Ambient Temperature Probes"
+ ::= { ne843PtmEntry 5 }
+
+ne843PtmEntryHamt OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Hi Ambient Temperature"
+ ::= { ne843PtmEntry 6 }
+
+ne843PtmEntryLamt OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Low Ambient Temperature"
+ ::= { ne843PtmEntry 7 }
+
+ne843PtmEntryNtm OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Battery Temperature Probes"
+ ::= { ne843PtmEntry 8 }
+
+ne843PtmEntryHbt OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Hi Battery Temperature"
+ ::= { ne843PtmEntry 9 }
+
+ne843PtmEntryLbt OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Low Battery Temperature"
+ ::= { ne843PtmEntry 10 }
+
+ne843PtmEntryNbut OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Number of Bus Temperature Probes"
+ ::= { ne843PtmEntry 11 }
+
+ne843PtmEntryHbut OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Hi Bus Temperature"
+ ::= { ne843PtmEntry 12 }
+
+ne843PtmEntryLbut OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Low Bust Temperature"
+ ::= { ne843PtmEntry 13 }
+
+
+
+--
+-- table PCS
+--
+
+ne843PcsTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843PcsEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all PIC Slot data"
+ ::= { ne843 49 }
+
+ne843PcsEntry OBJECT-TYPE
+SYNTAX Ne843PcsEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one PIC Slot"
+INDEX { ne843PcsEntryIndex }
+ ::= { ne843PcsTable 1 }
+
+Ne843PcsEntry ::= SEQUENCE {
+ne843PcsEntryIndex INTEGER,
+ne843PcsEntryIde DisplayString,
+ne843PcsEntryDes DisplayString,
+ne843PcsEntryStt DisplayString,
+ne843PcsEntryTyp DisplayString,
+ne843PcsEntryPole Integer32,
+ne843PcsEntryPolp Integer32,
+ne843PcsEntryPopn DisplayString,
+ne843PcsEntryTrp INTEGER,
+ne843PcsEntryBad INTEGER,
+ne843PcsEntryCbf DisplayString,
+ne843PcsEntrySlv INTEGER,
+ne843PcsEntryRtng Integer32
+}
+
+ne843PcsEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843PcsEntry 1 }
+
+ne843PcsEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843PcsEntry 2 }
+
+ne843PcsEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843PcsEntry 3 }
+
+ne843PcsEntryStt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Status"
+ ::= { ne843PcsEntry 4 }
+
+ne843PcsEntryTyp OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Type
+Values:
+Load,
+Batt,
+picType
+"
+ ::= { ne843PcsEntry 5 }
+
+ne843PcsEntryPole OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Number of Poles"
+ ::= { ne843PcsEntry 6 }
+
+ne843PcsEntryPolp OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Slot Pole Position"
+ ::= { ne843PcsEntry 7 }
+
+ne843PcsEntryPopn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Slot Pole Open/Closed
+Values:
+Open,
+Closed
+"
+ ::= { ne843PcsEntry 8 }
+
+ne843PcsEntryTrp OBJECT-TYPE
+SYNTAX INTEGER {
+off(0),
+on(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Slot Tripped
+Values:
+off(0),
+on(1)
+"
+ ::= { ne843PcsEntry 9 }
+
+ne843PcsEntryBad OBJECT-TYPE
+SYNTAX INTEGER {
+off(0),
+on(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Slot Bad
+Values:
+off(0),
+on(1)
+"
+ ::= { ne843PcsEntry 10 }
+
+ne843PcsEntryCbf OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Slot CB or Fuse
+Values:
+CB,
+Fuse
+"
+ ::= { ne843PcsEntry 11 }
+
+ne843PcsEntrySlv OBJECT-TYPE
+SYNTAX INTEGER {
+off(0),
+on(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Slot Slave
+Values:
+off(0),
+on(1)
+"
+ ::= { ne843PcsEntry 12 }
+
+ne843PcsEntryRtng OBJECT-TYPE
+SYNTAX Integer32
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Slot Rtng"
+ ::= { ne843PcsEntry 13 }
+
+
+
+--
+-- table DBY
+--
+
+ne843DbyTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843DbyEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Distribution Bay data"
+ ::= { ne843 50 }
+
+ne843DbyEntry OBJECT-TYPE
+SYNTAX Ne843DbyEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Distribution Bay"
+INDEX { ne843DbyEntryIndex }
+ ::= { ne843DbyTable 1 }
+
+Ne843DbyEntry ::= SEQUENCE {
+ne843DbyEntryIndex INTEGER,
+ne843DbyEntryIde DisplayString,
+ne843DbyEntryDes DisplayString,
+ne843DbyEntrySn DisplayString,
+ne843DbyEntryStt DisplayString,
+ne843DbyEntrySha Integer32,
+ne843DbyEntryNpl Integer32,
+ne843DbyEntryPmt DisplayString,
+ne843DbyEntryIds DisplayString,
+ne843DbyEntryBze INTEGER,
+ne843DbyEntryOle INTEGER,
+ne843DbyEntryOri DisplayString,
+ne843DbyEntryCmb INTEGER,
+ne843DbyEntrySmw DisplayString,
+ne843DbyEntryCca DisplayString
+}
+
+ne843DbyEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843DbyEntry 1 }
+
+ne843DbyEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843DbyEntry 2 }
+
+ne843DbyEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843DbyEntry 3 }
+
+ne843DbyEntrySn OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Serial Number"
+ ::= { ne843DbyEntry 4 }
+
+ne843DbyEntryStt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"State"
+ ::= { ne843DbyEntry 5 }
+
+ne843DbyEntrySha OBJECT-TYPE
+SYNTAX Integer32(0..4000)
+UNITS "Amps"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Shunt Rating (Amps)"
+ ::= { ne843DbyEntry 6 }
+
+ne843DbyEntryNpl OBJECT-TYPE
+SYNTAX Integer32(1..8)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Number of Panels"
+ ::= { ne843DbyEntry 7 }
+
+ne843DbyEntryPmt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Measurement Type"
+ ::= { ne843DbyEntry 8 }
+
+ne843DbyEntryIds OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Identification Style"
+ ::= { ne843DbyEntry 9 }
+
+ne843DbyEntryBze OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Buzzer Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843DbyEntry 10 }
+
+ne843DbyEntryOle OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Overload Latch Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843DbyEntry 11 }
+
+ne843DbyEntryOri OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Panel Orientation"
+ ::= { ne843DbyEntry 12 }
+
+ne843DbyEntryCmb OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Combine Panels
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843DbyEntry 13 }
+
+ne843DbyEntrySmw OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Shunt Miswired"
+ ::= { ne843DbyEntry 14 }
+
+ne843DbyEntryCca OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Circuit Assignment"
+ ::= { ne843DbyEntry 15 }
+
+
+
+--
+-- table DPN
+--
+
+ne843DpnTable OBJECT-TYPE
+SYNTAX SEQUENCE OF Ne843DpnEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Table of all Distribution Panel data"
+ ::= { ne843 51 }
+
+ne843DpnEntry OBJECT-TYPE
+SYNTAX Ne843DpnEntry
+MAX-ACCESS not-accessible
+STATUS current
+DESCRIPTION
+ "Entry of information for one Distribution Panel"
+INDEX { ne843DpnEntryIndex }
+ ::= { ne843DpnTable 1 }
+
+Ne843DpnEntry ::= SEQUENCE {
+ne843DpnEntryIndex INTEGER,
+ne843DpnEntryIde DisplayString,
+ne843DpnEntryDes DisplayString,
+ne843DpnEntryAdc Integer32,
+ne843DpnEntryVdc Integer32,
+ne843DpnEntryStt DisplayString,
+ne843DpnEntryPid Integer32,
+ne843DpnEntryEna INTEGER,
+ne843DpnEntryOld Integer32,
+ne843DpnEntryOlt Integer32,
+ne843DpnEntryOlr INTEGER,
+ne843DpnEntryPlt Integer32,
+ne843DpnEntryCct Integer32,
+ne843DpnEntryVlv DisplayString,
+ne843DpnEntryOvl DisplayString,
+ne843DpnEntryFaja DisplayString,
+ne843DpnEntryFajb DisplayString
+}
+
+ne843DpnEntryIndex OBJECT-TYPE
+SYNTAX INTEGER (0..2147483647)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Table Index"
+ ::= { ne843DpnEntry 1 }
+
+ne843DpnEntryIde OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Identifier"
+ ::= { ne843DpnEntry 2 }
+
+ne843DpnEntryDes OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Description"
+ ::= { ne843DpnEntry 3 }
+
+ne843DpnEntryAdc OBJECT-TYPE
+SYNTAX Integer32
+UNITS "Amps"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Current (Amps)"
+ ::= { ne843DpnEntry 4 }
+
+ne843DpnEntryVdc OBJECT-TYPE
+SYNTAX Integer32
+UNITS "mV"
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Voltage (mV)"
+ ::= { ne843DpnEntry 5 }
+
+ne843DpnEntryStt OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"State"
+ ::= { ne843DpnEntry 6 }
+
+ne843DpnEntryPid OBJECT-TYPE
+SYNTAX Integer32(1..8)
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Panel ID"
+ ::= { ne843DpnEntry 7 }
+
+ne843DpnEntryEna OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Enable
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843DpnEntry 8 }
+
+ne843DpnEntryOld OBJECT-TYPE
+SYNTAX Integer32(0..300)
+UNITS "Seconds"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Overload Delay (Seconds)"
+ ::= { ne843DpnEntry 9 }
+
+ne843DpnEntryOlt OBJECT-TYPE
+SYNTAX Integer32(0..4000)
+UNITS "amps"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Overload Threshold (amps)"
+ ::= { ne843DpnEntry 10 }
+
+ne843DpnEntryOlr OBJECT-TYPE
+SYNTAX INTEGER {
+disable(0),
+enable(1)
+}
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Redundant Overload
+Values:
+disable(0),
+enable(1)
+"
+ ::= { ne843DpnEntry 11 }
+
+ne843DpnEntryPlt OBJECT-TYPE
+SYNTAX Integer32(40000..60000)
+UNITS "mV"
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Power Loss Threshold (mV)"
+ ::= { ne843DpnEntry 12 }
+
+ne843DpnEntryCct OBJECT-TYPE
+SYNTAX Integer32(1..8)
+MAX-ACCESS read-write
+STATUS current
+DESCRIPTION
+"Input Circuit"
+ ::= { ne843DpnEntry 13 }
+
+ne843DpnEntryVlv OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Power Loss"
+ ::= { ne843DpnEntry 14 }
+
+ne843DpnEntryOvl OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Overload"
+ ::= { ne843DpnEntry 15 }
+
+ne843DpnEntryFaja OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Distribution Fuse A"
+ ::= { ne843DpnEntry 16 }
+
+ne843DpnEntryFajb OBJECT-TYPE
+SYNTAX DisplayString
+MAX-ACCESS read-only
+STATUS current
+DESCRIPTION
+"Distribution Fuse B"
+ ::= { ne843DpnEntry 17 }
+
+
+
+END