summaryrefslogtreecommitdiff
path: root/MIBS/hp/HP-SN-AGENT-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/hp/HP-SN-AGENT-MIB')
-rw-r--r--MIBS/hp/HP-SN-AGENT-MIB2914
1 files changed, 2914 insertions, 0 deletions
diff --git a/MIBS/hp/HP-SN-AGENT-MIB b/MIBS/hp/HP-SN-AGENT-MIB
new file mode 100644
index 0000000..7cb6395
--- /dev/null
+++ b/MIBS/hp/HP-SN-AGENT-MIB
@@ -0,0 +1,2914 @@
+-- SECTION 1: Top Level Definitions
+
+HP-SN-AGENT-MIB DEFINITIONS ::= BEGIN
+
+-- BigIron Router Switch Agent MIB Release 2.0.0
+-- Revision 10/11/99
+
+-- Copyright 1996 Foundry Networks, Inc.
+-- All rights reserved.
+-- This Foundry SNMP Management Information Base Specification
+-- (Specification) embodies Foundry's confidential and
+-- proprietary intellectual property. Foundry retains all
+-- title and ownership in the Specification, including any
+-- revisions.
+
+-- This Specification is supplied "AS IS," and Foundry makes
+-- no warranty, either express or implied, as to the use,
+-- operation, condition, or performance of the Specification.
+
+
+-- Imports
+
+IMPORTS
+ TimeTicks, IpAddress, Counter, Gauge
+ FROM RFC1155-SMI
+ OBJECT-TYPE
+ FROM RFC-1212
+ snChassis, snAgentSys, snStack
+ FROM HP-SN-ROOT-MIB;
+
+
+ -- textual conventions
+
+ DisplayString ::=
+ OCTET STRING
+ -- This data type is used to model textual information taken
+ -- from the NVT ASCII character set. By convention, objects
+ -- with this syntax are declared as having
+ --
+ -- SIZE (0..255)
+
+ MacAddress ::=
+ OCTET STRING (SIZE(6))
+ -- This data type is used to model media addresses. For many
+ -- types of media, this will be in a binary representation.
+ -- For example, an ethernet address would be represented as
+ -- a string of 6 octets.
+
+-- Groups
+
+snChasGen OBJECT IDENTIFIER ::= { snChassis 1 }
+snChasPwr OBJECT IDENTIFIER ::= { snChassis 2 }
+snChasFan OBJECT IDENTIFIER ::= { snChassis 3 }
+
+
+-- SECTION 2: MIB Objects
+
+
+-- General Chassis Information
+
+snChasType OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The chassis type represents the type
+ of Foundry product being managed. "
+ ::= { snChasGen 1 }
+
+
+
+snChasSerNum OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the chassis. If the
+ serial number is unknown or unavailable then
+ the value should be a zero length string."
+ ::= { snChasGen 2 }
+
+
+
+-- Power Supply Status
+
+
+snChasPwrSupplyStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A bit array that contains the value of the
+ Chassis Power Supplies. This is a packed bit string;
+ the 2 power supplies status are encoded into 4 bits
+ (a nibble).
+
+ There are multiple power supplies per chassis in this release.
+ The following shows the meaning of each bit:
+ (bit 0 is the least significant bit).
+
+ bit position meaning
+ ------------ -------
+ 12-31 reserved
+ 11 Power Supply 4 DC (0=bad, 1=good).
+ 10 Power Supply 3 DC (0=bad, 1=good).
+ 9 Power Supply 4 present status (0=present, 1=not-present).
+ 8 Power Supply 3 present status (0=present, 1=not-present).
+ 4-7 reserved
+ 3 Power Supply 2 DC (0=bad, 1=good).
+ 2 Power Supply 1 DC (0=bad, 1=good).
+ 1 Power Supply 2 present status (0=present, 1=not-present).
+ 0 Power Supply 1 present status (0=present, 1=not-present)."
+ ::= { snChasGen 3 }
+
+
+-- Fan Status
+
+
+snChasFanStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A bit array that contains the value of the
+ fan status. This is a packed bit string. The
+ status of each fan is encoded into one bit.
+
+ bit value meaning
+ --------- -------
+ 0 fan failure.
+ 1 fan good.
+
+ There are two fans per VLAN Switch chassis in this release.
+ The following shows the meaning of each bit:
+ (bit 0 is the least significant bit).
+
+ bit position meaning
+ ------------ -------
+ 4-31 reserved
+ 3 fan4 status
+ 2 fan3 status
+ 1 fan2 status
+ 0 fan1 status"
+ ::= { snChasGen 4 }
+
+
+
+
+snChasMainBrdDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The main board description string. (It is obsoleted for Chassis Product)"
+ ::= { snChasGen 5 }
+
+
+snChasMainPortTotal OBJECT-TYPE
+ SYNTAX INTEGER (1..24)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of ports for the main board. (It is obsoleted for Chassis Product)"
+ ::= { snChasGen 6 }
+
+
+snChasExpBrdDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The expansion board description string. Expansion
+ board are those boards attaching on the main board.
+ (It is obsoleted for Chassis Product)"
+ ::= { snChasGen 7 }
+
+
+snChasExpPortTotal OBJECT-TYPE
+ SYNTAX INTEGER (1..24)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of ports for the expansion board.
+ (It is obsoleted for Chassis Product)"
+ ::= { snChasGen 8 }
+
+
+snChasStatusLeds OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A bit array that contains the value of the
+ front panel status LEDs. This is a bit-map;
+ each LED is encoded into 1 bit for each switch
+ port. The maximum number of ports in one chassis
+ is 24 that means 24 Ports Status LEDs. The expansion port
+ number always begins from the last main port number.
+ The following shows the meaning of each bit for each
+ switch port:
+
+ bit value meaning
+ -------- ---------
+ 0 off (Link off)
+ 1 on (Link on)
+
+ The bitmap of LEDs are as following:
+
+ (Port1) (Port4) (Port8)
+ Bit (Bit0) (Bit3) (Bit7)
+ Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
+ Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
+ Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
+ --------"
+ ::= { snChasGen 9 }
+
+
+snChasTrafficLeds OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A bit array that contains the value of the
+ front panel traffic LEDs. This is a packed bit string;
+ each LED is encoded into 1 bit for each switch
+ port. The maximum number of ports in one chassis
+ is 24 that means 24 Ports Traffic LEDs. The expansion port
+ number always begins from the last main port number.
+ The following shows the meaning of each bit for each
+ switch port:
+
+ bit value meaning
+ -------- ---------
+ 0 off (no traffic)
+ 1 on (traffic)
+
+ The bitmap of LEDs are as following:
+
+ (Port1) (Port4) (Port8)
+ Bit (Bit0) (Bit3) (Bit7)
+ Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
+ Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
+ Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
+ --------"
+ ::= { snChasGen 10 }
+
+
+snChasMediaLeds OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A bit array that contains the value of the
+ front panel media LEDs. This is a packed bit string;
+ each LED is encoded into 1 bit for each switch port.
+ The maximum number of ports in one chassis is 24
+ that means 24 Ports Media LEDs. The expansion port
+ number always begins from the last main port number.
+ The following shows the meaning of each bit for each
+ switch port:
+
+ bit value meaning
+ --------- -------
+ 0 half duplex
+ 1 full duplex
+
+ The bitmap of LEDs are as following:
+ (Port1) (Port4) (Port8)
+ Bit (Bit0) (Bit3) (Bit7)
+ Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
+ Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
+ Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
+ ---------"
+ ::= { snChasGen 11 }
+
+
+snChasEnablePwrSupplyTrap OBJECT-TYPE
+ SYNTAX INTEGER { disabled(0), enabled(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the SNMP agent process is
+ permitted to generate power supply failure traps."
+ DEFVAL { enabled }
+ ::= { snChasGen 12 }
+
+snChasMainBrdId OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The main board identifier, which can uniquely identify a board
+ type. It is an encoded octet string with the following meaning:
+ octet 0 - octet string format version, which identifies the
+ format of this string.
+
+ If format version octet has the value 1, the octets after the
+ version octet have the following meaning:
+ octet 1 - product type, FIWG=0x57, FIBB=0x42, FIMLS=0x4D
+ NI=0x4E, TI=0x54, TIRT=0x52
+ octet 2 - board type, POWERPC=1, ALPHA=2
+ The length of the octet string is 27.
+
+ If format version octet has the value 2, the octets after the
+ version octet have the following meaning:
+ octet 1 - product type:
+ BI_WG 0x57
+ BI_BB 0x42
+ BI_NI 0x4E
+ octet 2 - module type:
+ FI_MASTER_FIBER_8G 0x7
+ FI_MASTER_FIBER_4G 0x5
+ FI_MASTER_FIBER_2G 0x4
+ FI_SLAVE_COPPER_24 0xB
+ MASTER_FIBER_8G 0x0
+ MASTER_FIBER_4G 0x1
+ MASTER_FIBER_2G 0x12
+ MASTER_FIBER_0G 0x14
+ MASTER_COPPER_16 0x2
+ MASTER_COPPER_8G 0x6
+ MASTER_COPPER_12_2 0x9
+ SLAVE_FIBER_8G 0x8
+ SLAVE_FIBER_4G 0x3
+ SLAVE_COPPER_20 0xA
+ SLAVE_COPPER_24 0xA
+ SLAVE_100FX_8 0xD
+ SLAVE_100FX_16 0xC
+ SLAVE_COPPER_8G 0xE
+ SLAVE_COPPER_16_2 0xF
+ STACK_FIBER_8G 0x10
+ STACK_COPPER_8G 0x11
+ SLAVE_100FX_24 0x13
+ The length of the octet string is 28.
+
+ Both format version 1 and 2:
+ octet 3 - processor type, PVR_M603=3, PVR_M604=4, PVR_M603E=6,
+ PVR_M603EV=7, PVR_M604E=9
+ octet 4 to
+ octet 5 - processor speed in MHz
+ octet 6 - MAC type:
+ MAC_SEEQ_10_100=1,
+ MAC_DEC_10_100=2,
+ MAC_SEEQ_1000=5,
+ MAC_GMAC_1000=6,
+ MAC_VLSI_1000=9
+ octet 7 - PHY type, PHY_NONE=0, PHY_QSI=1, PHY_ICS=3,
+ PHY_NATIONAL=4, PHY_LEVEL1=6, PHY_LEVEL16=7,
+ PHY_LEVEL24=8
+ octet 8 - port type, COPPER=0, FIBER=1
+ octet 9 - fiber port type, NONFIBER=0, SX_FIBER=1,
+ LX_FIBER=2, LHX_FIBER=3, LX_SX_FIBER=4,
+ LHB_FIBER=5
+ octet 10 to
+ octet 13 - DRAM size in KBytes
+ octet 14 to
+ octet 17 - boot flash size in KBytes
+ octet 18 to
+ octet 21 - code flash size in KBytes
+ octet 22 to
+ octet 27 - serial number.
+
+ Format version 1 only:
+ octet 28 - chassis backplane type.
+ chassis4000 = 0x00
+ chassis8000 = 0x04
+ Turbo8 = 0x07 (stack2)
+ FastIron2 = 0x06 (stack1)"
+ ::= { snChasGen 13 }
+
+
+snChasExpBrdId OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The expansion board identifier. Expansion board are those
+ boards attaching on the main board. It is an encoded octet
+ string with the following meaning:
+ octet 0 - octet string format version, which identifies
+ the format of this string.
+ If format version octet has the value 1, the octets after
+ the version octet have the following meaning:
+ octet 1 - expansion board type, HUNDRED_MEG_1PORT=1,
+ HUNDRED_MEG_2PORT=2, HUNDRED_MEG_1PORT_COPPER=3,
+ HUNDRED_MEG_2PORT_COPPER=4, HUNDRED_MEG_2PORT_LX=5,
+ GIGA_1PORT=8, GIGA_2PORT=9
+ octet 2 - fiber port type, NONFIBER=0, SX_FIBER=1,
+ LX_FIBER=2, LHX_FIBER=3, LX_SX_FIBER=4
+ (It is obsoleted for Chassis Product)"
+ ::= { snChasGen 14 }
+
+
+snChasSpeedLeds OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A bit array that contains the value of the
+ front panel media LEDs. This is a packed bit string;
+ each LED is encoded into 1 bit for each switch port.
+ The maximum number of ports in one chassis is 24
+ that means 24 Ports Speed LEDs. The expansion port
+ number always begins from the last main port number.
+ The following shows the meaning of each bit for each
+ switch port:
+
+ bit value meaning
+ --------- -------
+ 0 10 MBit
+ 1 100 MBit
+
+ The bitmap of LEDs are as following:
+ (Port1) (Port4) (Port8)
+ Bit (Bit0) (Bit3) (Bit7)
+ Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
+ Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
+ Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
+ ---------"
+ ::= { snChasGen 15 }
+
+
+snChasEnableFanTrap OBJECT-TYPE
+ SYNTAX INTEGER { disabled(0), enabled(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the SNMP agent process is
+ permitted to generate fan failure traps."
+ DEFVAL { enabled }
+ ::= { snChasGen 16 }
+
+
+snChasIdNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..64))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An administratively-assigned chassis identity number,
+ used by inventory control."
+ ::= { snChasGen 17 }
+
+
+snChasActualTemperature OBJECT-TYPE
+ SYNTAX INTEGER (-110..250)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Temperature of the chassis. Each unit is 0.5 degrees Celcius.
+ Only management module built with temperature sensor hardware
+ is applicable. For those non-applicable management module, it
+ returns no-such-name."
+ ::= { snChasGen 18 }
+
+
+snChasWarningTemperature OBJECT-TYPE
+ SYNTAX INTEGER (0..250)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Actual temperature higher than this threshold value will trigger
+ the switch to send a temperature warning trap. Each unit is 0.5
+ degrees Celcius. Only management module built with temperature
+ sensor hardware is applicable. For those non-applicable management
+ module, it returns no-such-name."
+ ::= { snChasGen 19 }
+
+
+snChasShutdownTemperature OBJECT-TYPE
+ SYNTAX INTEGER (0..250)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Actual temperature higher than this threshold value will shutdown
+ a partial of the switch hardware to cool down the system. Each unit
+ is 0.5 degrees Celcius. Only management module built with temperature
+ sensor hardware is applicable. For those non-applicable management
+ module, it returns no-such-name."
+ ::= { snChasGen 20 }
+
+snChasEnableTempWarnTrap OBJECT-TYPE
+ SYNTAX INTEGER { disabled(0), enabled(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the SNMP agent process is
+ permitted to generate temperature warning traps."
+ DEFVAL { enabled }
+ ::= { snChasGen 21 }
+
+
+-- Power Supply Table
+
+
+snChasPwrSupplyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnChasPwrSupplyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of each power supply information. Only installed
+ power supply appears in a table row."
+ ::= { snChasPwr 1 }
+
+snChasPwrSupplyEntry OBJECT-TYPE
+ SYNTAX SnChasPwrSupplyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A row in the power supply table."
+ INDEX { snChasPwrSupplyIndex }
+ ::= { snChasPwrSupplyTable 1 }
+
+SnChasPwrSupplyEntry ::= SEQUENCE {
+ snChasPwrSupplyIndex
+ INTEGER,
+ snChasPwrSupplyDescription
+ DisplayString,
+ snChasPwrSupplyOperStatus
+ INTEGER
+ }
+
+snChasPwrSupplyIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to power supply table."
+ ::= { snChasPwrSupplyEntry 1 }
+
+snChasPwrSupplyDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The power supply description string."
+ ::= { snChasPwrSupplyEntry 2 }
+
+snChasPwrSupplyOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ normal(2),
+ failure(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The power supply operation status."
+ ::= { snChasPwrSupplyEntry 3 }
+
+
+-- Fan Table
+
+
+snChasFanTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnChasFanEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of each fan information. Only installed
+ fan appears in a table row."
+ ::= { snChasFan 1 }
+
+snChasFanEntry OBJECT-TYPE
+ SYNTAX SnChasFanEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A row in the fan table."
+ INDEX { snChasFanIndex }
+ ::= { snChasFanTable 1 }
+
+SnChasFanEntry ::= SEQUENCE {
+ snChasFanIndex
+ INTEGER,
+ snChasFanDescription
+ DisplayString,
+ snChasFanOperStatus
+ INTEGER
+ }
+
+snChasFanIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to fan table."
+ ::= { snChasFanEntry 1 }
+
+snChasFanDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The fan description string."
+ ::= { snChasFanEntry 2 }
+
+snChasFanOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ normal(2),
+ failure(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The fan operation status."
+ ::= { snChasFanEntry 3 }
+
+
+-- Agent Groups
+
+snAgentGbl OBJECT IDENTIFIER ::= { snAgentSys 1 }
+snAgentBrd OBJECT IDENTIFIER ::= { snAgentSys 2 }
+snAgentTrp OBJECT IDENTIFIER ::= { snAgentSys 3 }
+snAgentBoot OBJECT IDENTIFIER ::= { snAgentSys 4 }
+snAgCfgEos OBJECT IDENTIFIER ::= { snAgentSys 5 }
+snAgentLog OBJECT IDENTIFIER ::= { snAgentSys 6 }
+snAgentSysParaConfig OBJECT IDENTIFIER ::= { snAgentSys 7 }
+snAgentConfigModule OBJECT IDENTIFIER ::= { snAgentSys 8 }
+snAgentUser OBJECT IDENTIFIER ::= { snAgentSys 9 }
+snAgentRedundant OBJECT IDENTIFIER ::= { snAgentSys 10 }
+
+
+
+-- SECTION 2: MIB Objects
+
+
+-- Agent's Global Group
+
+snAgReload OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ running(2),
+ reset(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Action object to reboot the agent.
+ The following values can only be read:
+ other(1).....agent in unknown or other state
+ running(2)...agent running
+
+ The following value can be written:
+ reset(3).....do a hard reset
+
+ The agent will return a
+ response before the action occurs."
+ ::= { snAgentGbl 1 }
+
+snAgEraseNVRAM OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ error(2),
+ erase(3),
+ erasing(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Action object to erase NVRAM of the agent.
+ The following values can only be read:
+ normal(1)
+ error(2)... operation failed or bad flash
+ erasing(4)...agent is erasing NVRAM flash
+
+ The following value can be written:
+ erase(3).....do erase
+
+ The agent will return a response even before the erase is done.
+ And the read value will be erasing until erase is done.
+ And the erase request will be rejected until error or normal."
+ ::= { snAgentGbl 2 }
+
+snAgWriteNVRAM OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ error(2),
+ write(3),
+ writing(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Action object to save all configuration info to
+ NVRAM of the agent.
+ The following values can only be read:
+ normal(1)
+ error(2)... operation failed or bad flash
+ writing(4)...agent is writing NVRAM flash
+
+ The following value can be written:
+ write(3).....do write
+
+ The agent will return a response even before the write is done.
+ And the read value will be writing until write is done.
+ And the write request will be rejected until error or normal."
+ ::= { snAgentGbl 3 }
+
+snAgConfigFromNVRAM OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ error(2),
+ config(3),
+ configing(4)
+ }
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Action object to config the switch from NVRAM of the agent.
+ The following values can only be read:
+ normal(1)
+ error(2)... operation failed or bad flash
+ configing(4)...configing from NVRAM flash is in process.
+ The following value can be written:
+ config(3).....do config
+
+ The agent will return a response after config is done."
+ ::= { snAgentGbl 4 }
+
+-- image and config file down/up load
+
+snAgTftpServerIp OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The tftp server address, this will be used for both download/upload
+ image file and config file."
+ ::= { snAgentGbl 5 }
+
+snAgImgFname OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..32))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name of the image file including path currently associated
+ with the system. When the object is not used, the value is a
+ zero length string."
+ ::= { snAgentGbl 6 }
+
+
+snAgImgLoad OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ flashPrepareReadFailure(2),
+ flashReadError(3),
+ flashPrepareWriteFailure(4),
+ flashWriteError(5),
+ tftpTimeoutError(6),
+ tftpOutOfBufferSpace(7),
+ tftpBusy(8),
+ tftpRemoteOtherErrors(9),
+ tftpRemoteNoFile(10),
+ tftpRemoteBadAccess(11),
+ tftpRemoteDiskFull(12),
+ tftpRemoteBadOperation(13),
+ tftpRemoteBadId(14),
+ tftpRemoteFileExists(15),
+ tftpRemoteNoUser(16),
+ operationError(17),
+ loading(18),
+ uploadPrimary(19),
+ downloadPrimary(20),
+ uploadSecondary(21),
+ downloadSecondary(22),
+ tftpWrongFileType(23)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Action object to down/up load a new image
+ to the agent. The following values:
+ Error values: from normal(1) to operationError(17) and tftpWrongFileType(23).
+ loading(18) .. operation is in process.
+
+ The following values are used for set :
+ uploadPrimary(19)..upload the Primary image from flash to tftp server.
+ downloadPrimary(20)..download the Primary image from tftp server to flash.
+ uploadSecondary(21)..upload the Secondary image from flash to tftp server.
+ downloadSecondary(22)..download the Secondary image from tftp server to flash.
+
+ The image filename is defined in
+ snAgImgFname. The tftp server address is defined in snAgTftpServerIp.
+ Atomic set of snAgImgLoad, snAgImgFname and
+ snAgTftpServerIp is required to allow down/up load to happen.
+ And the write request will be rejected during loading until error
+ or normal."
+ ::= { snAgentGbl 7 }
+
+snAgCfgFname OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..32))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name of the config file(s) including path currently associated
+ with the system. Some agents in special
+ situations may support a value which contains
+ multiple file names instead of a single file
+ name. Multiple names are specified as a list
+ of file names separated by semicolons (;).
+ When the object is not used, the value is a
+ zero length string."
+ ::= { snAgentGbl 8 }
+
+snAgCfgLoad OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ flashPrepareReadFailure(2),
+ flashReadError(3),
+ flashPrepareWriteFailure(4),
+ flashWriteError(5),
+ tftpTimeoutError(6),
+ tftpOutOfBufferSpace(7),
+ tftpBusy(8),
+ tftpRemoteOtherErrors(9),
+ tftpRemoteNoFile(10),
+ tftpRemoteBadAccess(11),
+ tftpRemoteDiskFull(12),
+ tftpRemoteBadOperation(13),
+ tftpRemoteBadId(14),
+ tftpRemoteFileExists(15),
+ tftpRemoteNoUser(16),
+ operationError(17),
+ loading(18),
+ uploadFromFlashToServer(20),
+ downloadToFlashFromServer(21),
+ uploadFromDramToServer(22),
+ downloadToDramFromServer(23),
+ uploadFromFlashToNMS(24),
+ downloadToFlashFromNMS(25),
+ uploadFromDramToNMS(26),
+ downloadToDramFromNMS(27),
+ operationDoneWithNMS(28),
+ tftpWrongFileType(29)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Action object to down/up load a config image
+ to the agent. The following values can be
+ read :
+ Error values: from normal(1) to operationError(17) and tftpWrongFileType(29).
+ loading(18) .. operation is in process.
+
+
+ The following value can be used to set:
+ uploadFromFlashToServer(20)..upload the config from flash
+ to tftp server.
+ downloadToFlashFromServer(21)..download the config to flash
+ from tftp server.
+ uploadFromDramToServer(22)..upload the config from DRAM
+ to tftp server.
+ downloadToDramFromServer(23)..download the config to DRAM
+ from tftp server.
+
+ The following value can be used to set:
+ uploadFromFlashToNMS(24)..upload the config from flash to NMS.
+ downloadToFlashFromNMS(25)..download the config to flash from NMS.
+ uploadFromDramToNMS(26)..upload the config from DRAM to NMS.
+ downloadToDramFromNMS(27)..download the config to DRAM from NMS.
+
+ The config filename is defined in
+ snAgCfgFname. The tftp server address is defined in snAgTftpServerIp.
+ Atomic set of snAgCfgLoad, snAgCfgFname and snAgTftpServerIp is
+ required to allow down/up load to happen. And the write request
+ will be rejected during loading until error or normal.
+ For those NMS commands from (24) to (27), The snAgCfgEosTable MIB must
+ be sent along in one PDU. A seperate write memory cli or set
+ snAgWriteNVRAM is required to save the config to NVRAM."
+ ::= { snAgentGbl 9 }
+
+-- default gateway ip address
+
+snAgDefGwayIp OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The default gateway (router) address."
+ ::= { snAgentGbl 10 }
+
+
+-- image version
+
+snAgImgVer OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The version of the running software in the form
+ 'major.minor.maintenance[letters]'."
+ ::= { snAgentGbl 11 }
+
+snAgFlashImgVer OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The version of the software image saved in local
+ storage such as flash memory in the form
+ 'major.minor.maintenance[letters]'. If not
+ known or not available, then the value is
+ a zero length string."
+ ::= { snAgentGbl 12 }
+
+snAgGblIfIpAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The interface ip address."
+ ::= { snAgentGbl 13 }
+
+snAgGblIfIpMask OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The interface ip address mask."
+ ::= { snAgentGbl 14 }
+
+snAgGblPassword OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..48))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "System Security Access Password and this is only
+ allowed to use for setting but not for reading.
+ An SNMP-Get will get an zero string."
+ ::= { snAgentGbl 15 }
+
+snAgTrpRcvrCurEntry OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current total entries of the Trap
+ Receiver Table are created."
+ ::= { snAgentGbl 16 }
+
+snAgGblDataRetrieveMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ nextbootCfg(0),
+ operationalData(1)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "By default, this mode is set to nextbootCfg(0).
+ The VLAN Table and Port-STP Table data will be retrieved
+ according to this mode.
+ nextbootCfg(0).........the nextboot configuration data are retrieved
+ operationalData(1)..........the current running data are retrieved"
+ ::= { snAgentGbl 19 }
+
+
+snAgSystemLog OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(5))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The system log object to indicate whether any Network
+ Management Station(NMS) has login. The first byte
+ of the octet string is the value decribed below and
+ followed by 4 bytes of secret code.
+ login(1)..... a value for a NMS to login.
+ heartbeat(2)... a value for the login NMS periodically to
+ checkin; Otherwise, the Agent will automatically
+ set this object to logout(3) after a timeout
+ period.
+ logout(3).... a value for a NMS to logout.
+ changePassword(4).... a value for the login NMS to change
+ password, only if snAgGblPasswordChangeMode
+ was configured to 'anyMgmtEntity'.
+ changeReadOnlyCommunity(5).... a value for the login NMS
+ to change the read-only community string,
+ only if snAgGblPasswordChangeMode was
+ configured to 'anyMgmtEntity'.
+ changeReadWriteCommunity(6).... a value for the login NMS
+ to change the read-write community string,
+ only if snAgGblPasswordChangeMode was
+ configured to 'anyMgmtEntity'."
+ ::= { snAgentGbl 20 }
+
+
+snAgGblEnableColdStartTrap OBJECT-TYPE
+ SYNTAX INTEGER { disabled(0), enabled(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the SNMP agent process is
+ permitted to generate cold start traps."
+ DEFVAL { enabled }
+ ::= { snAgentGbl 21 }
+
+
+snAgGblEnableLinkUpTrap OBJECT-TYPE
+ SYNTAX INTEGER { disabled(0), enabled(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the SNMP agent process is
+ permitted to generate link up traps."
+ DEFVAL { enabled }
+ ::= { snAgentGbl 22 }
+
+
+snAgGblEnableLinkDownTrap OBJECT-TYPE
+ SYNTAX INTEGER { disabled(0), enabled(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the SNMP agent process is
+ permitted to generate link down traps."
+ DEFVAL { enabled }
+ ::= { snAgentGbl 23 }
+
+snAgGblPasswordChangeMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ anyMgmtEntity(1),
+ consoleAndTelnet(2),
+ consoleOnly(3),
+ telnetOnly(4) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Specify which management entity is allowed to change
+ the password. 'anyMgmtEntity' management entities are
+ SNMP management station, console command line interface,
+ and telnet command line interface. For security reason,
+ this object can only be modified by console command line
+ interface or telnet command line interface. The default
+ value is 'consoleAndTelnet', of which both console and
+ telnet command line interfaces are allowed to change
+ the password."
+ ::= { snAgentGbl 24 }
+
+snAgGblReadOnlyCommunity OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..32))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "SNMP read community string and this is only allowed
+ to use for setting but not for reading. An SNMP-Get
+ will get an zero length string."
+ ::= { snAgentGbl 25 }
+
+snAgGblReadWriteCommunity OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..32))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "SNMP read-write community string and this is only
+ allowed to use for setting but not for reading. An
+ SNMP-Get will get an zero length string."
+ ::= { snAgentGbl 26 }
+
+snAgGblCurrentSecurityLevel OBJECT-TYPE
+ SYNTAX INTEGER (0..5)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This represnts the current log-in security level.
+ Each level of security requires a password to permit
+ user for different system configurations."
+ ::= { snAgentGbl 27 }
+
+snAgGblSecurityLevelSet OBJECT-TYPE
+ SYNTAX INTEGER (0..5)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This shows which the security level password to be set."
+ ::= { snAgentGbl 28 }
+
+snAgGblLevelPasswordsMask OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This shows the bitmap of level passwords which successfully assigned to the system."
+ ::= { snAgentGbl 29 }
+
+snAgGblQueueOverflow OBJECT-TYPE
+ SYNTAX INTEGER { false(0), true(1) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "false - The device queues are not overflow.
+ true - The device queues are overflow."
+ ::= { snAgentGbl 30 }
+
+snAgGblBufferShortage OBJECT-TYPE
+ SYNTAX INTEGER { false(0), true(1) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "false - The device buffers are adequate.
+ true - The device buffers are in shortage."
+ ::= { snAgentGbl 31 }
+
+snAgGblDmaFailure OBJECT-TYPE
+ SYNTAX INTEGER { false(0), true(1) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "false - The device DMAs are in good condition.
+ true - One of the DMAs in the device fails."
+ ::= { snAgentGbl 32 }
+
+snAgGblResourceLowWarning OBJECT-TYPE
+ SYNTAX INTEGER { false(0), true(1) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "false - No, the device does not have resource-low-warning.
+ true - Yes, the device does have resource-low-warning."
+ ::= { snAgentGbl 33 }
+
+snAgGblExcessiveErrorWarning OBJECT-TYPE
+ SYNTAX INTEGER { false(0), true(1) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "false - No, the device does not have any excessive collision, FCS errors, alignment warning etc.
+ true - Yes, the device does have."
+ ::= { snAgentGbl 34 }
+
+snAgGblCpuUtilData OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The statistics collection of utilization of the CPU in the device."
+ ::= { snAgentGbl 35 }
+
+snAgGblCpuUtilCollect OBJECT-TYPE
+ SYNTAX INTEGER { disabled(0), enabled(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "enable(1) - The beginning of statistics collection of utilization of the CPU in the device.
+ disable(0) - The end of statistics collection of utilization of the CPU in the device."
+ ::= { snAgentGbl 36 }
+
+snAgGblTelnetTimeout OBJECT-TYPE
+ SYNTAX INTEGER (0..240)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Telnet session idling timeout value. Writing value 0 to
+ this object never timeouts any telnet sessions. Each value
+ unit is one minute."
+ ::= { snAgentGbl 37 }
+
+snAgGblEnableWebMgmt OBJECT-TYPE
+ SYNTAX INTEGER { disabled(0), enabled(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enable/disable web management."
+ DEFVAL { enabled }
+ ::= { snAgentGbl 38 }
+
+snAgGblSecurityLevelBinding OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This represnts the binding of a given password to which
+ security level. A value of 255 indicates an invalid
+ binding."
+ ::= { snAgentGbl 39 }
+
+snAgGblEnableSLB OBJECT-TYPE
+ SYNTAX INTEGER { disabled(0), enabled(1) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Enable/disable Server Load Balancing."
+ ::= { snAgentGbl 40 }
+
+snAgSoftwareFeature OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A bit string representing the software feature of the running
+ switch/router image. These features were conditional compiled
+ to different product images. For each bit, exist feature has
+ a value of 1, but non-exist feature has a value of 0.
+ octet 0, bit 0 - RMON
+ octet 0, bit 1 - ipx switching
+ octet 0, bit 2 - server load balancing
+ octet 0, bit 3 - layer 3 filter in switch
+ octet 0, bit 4 - ipx routing
+ octet 0, bit 5 - appletalk routing
+ octet 0, bit 6 - ip multicast routing
+ octet 0, bit 7 - local access control
+ octet 1, bit 0 - BGP routing
+ octet 1, bit 1 - loopback interface
+ octet 1, bit 2 - BigIron multi-management module
+ octet 1, bit 3 - BigIron SYSIF II
+ octet 1, bit 4 - BigIron POS support
+ octet 1, bit 5 - appletalk cable vlan
+ octet 1, bit 6 - 64 subnet
+ octet 1, bit 7 - multi-slot trunk
+ octet 2, bit 0 - TACACS
+ octet 2, bit 1 - Gigabit Ethernet port auto-negotiation mode
+ octet 2, bit 2 - FSRP
+ octet 2, bit 3 - Exodus requested OSPF enhancement
+ octet 2, bit 4 - OSPF NSSA
+ octet 2, bit 5 - POS
+ octet 2, bit 6 - QOS
+ octet 2, bit 7 - Single Span
+ octet 3, bit 0 - Fast Span
+ octet 3, bit 1 - Base L3
+ octet 3, bit 2 - static log buffer
+ Bit 0 is the least significant bit of an octet, and
+ bit 7 is the most significant bit of an octet."
+ ::= { snAgentGbl 41 }
+
+snAgGblEnableModuleInsertedTrap OBJECT-TYPE
+ SYNTAX INTEGER { disabled(0), enabled(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the SNMP agent process is permitted to
+ generate hardware module inserted to chassis traps."
+ DEFVAL { enabled }
+ ::= { snAgentGbl 42 }
+
+snAgGblEnableModuleRemovedTrap OBJECT-TYPE
+ SYNTAX INTEGER { disabled(0), enabled(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the SNMP agent process is permitted to
+ generate hardware module removed from chassis traps."
+ DEFVAL { enabled }
+ ::= { snAgentGbl 43 }
+
+snAgGblTrapMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A generic trap message string."
+ ::= { snAgentGbl 44 }
+
+snAgGblEnableTelnetServer OBJECT-TYPE
+ SYNTAX INTEGER { disabled(0), enabled(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enable or disable telnet server in device."
+ DEFVAL { enabled }
+ ::= { snAgentGbl 45 }
+
+snAgGblTelnetPassword OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..48))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Telnet Access Password and this is only
+ allowed to use for setting but not for reading.
+ An SNMP-Get will get an zero string."
+ ::= { snAgentGbl 46 }
+
+snAgBuildDate OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date of the built software."
+ ::= { snAgentGbl 47 }
+
+snAgBuildtime OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The time of the built software."
+ ::= { snAgentGbl 48 }
+
+snAgBuildVer OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The version of the built software in the form
+ 'major.minor.maintenance[letters]'."
+ ::= { snAgentGbl 49 }
+
+-- Agent Board Table
+
+
+snAgentBrdTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnAgentBrdEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of each physical board information."
+ ::= { snAgentBrd 1 }
+
+snAgentBrdEntry OBJECT-TYPE
+ SYNTAX SnAgentBrdEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A row in the Agent Board table."
+ INDEX { snAgentBrdIndex }
+ ::= { snAgentBrdTable 1 }
+
+SnAgentBrdEntry ::= SEQUENCE {
+ snAgentBrdIndex
+ INTEGER,
+ snAgentBrdMainBrdDescription
+ DisplayString,
+ snAgentBrdMainBrdId
+ OCTET STRING,
+ snAgentBrdMainPortTotal
+ INTEGER,
+ snAgentBrdExpBrdDescription
+ DisplayString,
+ snAgentBrdExpBrdId
+ OCTET STRING,
+ snAgentBrdExpPortTotal
+ INTEGER,
+ snAgentBrdStatusLeds
+ INTEGER,
+ snAgentBrdTrafficLeds
+ INTEGER,
+ snAgentBrdMediaLeds
+ INTEGER,
+ snAgentBrdSpeedLeds
+ INTEGER,
+ snAgentBrdModuleStatus
+ INTEGER,
+ snAgentBrdRedundantStatus
+ INTEGER,
+ snAgentBrdAlarmLeds
+ INTEGER,
+ snAgentBrdTxTrafficLeds
+ INTEGER,
+ snAgentBrdRxTrafficLeds
+ INTEGER
+ }
+
+snAgentBrdIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..8)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Agent Interface Table."
+ ::= { snAgentBrdEntry 1 }
+
+snAgentBrdMainBrdDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The main board description string."
+ ::= { snAgentBrdEntry 2 }
+
+snAgentBrdMainBrdId OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The main board identifier, which can uniquely identify a board
+ type. It is an encoded octet string with the following meaning:
+ octet 0 - octet string format version, which identifies the
+ format of this string.
+ If format version octet has the value 2, the octets after the
+ version octet have the following meaning:
+ octet 1 - product type:
+ BI_WG 0x57
+ BI_BB 0x42
+ BI_NI 0x4E
+ octet 2 - module type:
+ MASTER_FIBER_8G 0x0
+ MASTER_FIBER_4G 0x1
+ MASTER_FIBER_2G 0x12
+ MASTER_FIBER_0G 0x14
+
+ MASTER_COPPER_16 0x2
+ MASTER_COPPER_8G 0x6
+ MASTER_COPPER_12_2 0x9
+
+ SLAVE_FIBER_8G 0x8
+ SLAVE_FIBER_4G 0x3
+ SLAVE_FIBER_2G 0x17
+
+ SLAVE_COPPER_8G 0xE
+ SLAVE_COPPER_2G 0x18
+ SLAVE_COPPER_16_2 0xF
+ SLAVE_COPPER_20 0xA
+ SLAVE_COPPER_24 0xA
+
+ SLAVE_100FX_8 0xD
+ SLAVE_100FX_16 0xC
+ SLAVE_100FX_24 0x13
+
+ STACK_FIBER_8G 0x10
+ STACK_COPPER_8G 0x11
+
+ POS_622M 0x15
+ POS_155M 0x16
+ octet 3 - processor type, PVR_M603=3, PVR_M604=4, PVR_M603E=6,
+ PVR_M603EV=7, PVR_M604E=9
+ octet 4 to
+ octet 5 - processor speed in MHz
+ octet 6 - MAC type:
+ MAC_SEEQ_10_100=1,
+ MAC_DEC_10_100=2,
+ MAC_SEEQ_1000=5,
+ MAC_GMAC_1000=6,
+ MAC_VLSI_1000=9
+ octet 7 - PHY type, PHY_NONE=0, PHY_QSI=1, PHY_ICS=3,
+ PHY_NATIONAL=4, PHY_LEVEL1=6, PHY_LEVEL16=7,
+ PHY_LEVEL24=8
+ octet 8 - port type, COPPER=0, FIBER=1
+ octet 9 - fiber port type, NONFIBER=0, SX_FIBER=1,
+ LX_FIBER=2, LHX_FIBER=3
+ octet 10 to
+ octet 13 - DRAM size in KBytes
+ octet 14 to
+ octet 17 - boot flash size in KBytes
+ octet 18 to
+ octet 21 - code flash size in KBytes
+ octet 22 to
+ octet 27 - serial number.
+ octet 28 - chassis backplane type.
+ chassis4000 = 0x00
+ chassis8000 = 0x04
+ Turbo8 = 0x07 (stack2)
+ FastIron2 = 0x06 (stack1)"
+ ::= { snAgentBrdEntry 3 }
+
+
+snAgentBrdMainPortTotal OBJECT-TYPE
+ SYNTAX INTEGER (1..32)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of ports for the main board."
+ ::= { snAgentBrdEntry 4 }
+
+
+snAgentBrdExpBrdDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The expansion board description string. Expansion
+ board are those boards attaching on the main board."
+ ::= { snAgentBrdEntry 5 }
+
+
+snAgentBrdExpBrdId OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The expansion board identifier. Expansion board are those
+ boards attaching on the main board. It is an encoded octet
+ string with the following meaning:
+ octet 0 - octet string format version, which identifies
+ the format of this string.
+ If format version octet has the value 1, the octets after
+ the version octet have the following meaning:
+ octet 1 - expansion board type, HUNDRED_MEG_1PORT=1,
+ HUNDRED_MEG_2PORT=2, HUNDRED_MEG_1PORT_COPPER=3,
+ HUNDRED_MEG_2PORT_COPPER=4, HUNDRED_MEG_2PORT_LX=5,
+ GIGA_1PORT=8, GIGA_2PORT=9
+ octet 2 - fiber port type, NONFIBER=0, SX_FIBER=1,
+ LX_FIBER=2, LHX_FIBER=3, LX_SX_FIBER=4"
+ ::= { snAgentBrdEntry 6 }
+
+
+snAgentBrdExpPortTotal OBJECT-TYPE
+ SYNTAX INTEGER (1..24)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of ports for the expansion board."
+ ::= { snAgentBrdEntry 7 }
+
+
+snAgentBrdStatusLeds OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A bit array that contains the value of the
+ front panel status LEDs. This is a bit-map;
+ each LED is encoded into 1 bit for each switch
+ port. The maximum number of ports in one chassis
+ is 32 that means 32 Ports Status LEDs. The expansion port
+ number always begins from the last main port number.
+ The following shows the meaning of each bit for each
+ switch port:
+
+ bit value meaning
+ -------- ---------
+ 0 off (Link off)
+ 1 on (Link on)
+
+ The bitmap of LEDs are as following:
+
+ (Port1) (Port4) (Port8)
+ Bit (Bit0) (Bit3) (Bit7)
+ Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
+ Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
+ Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
+ --------"
+ ::= { snAgentBrdEntry 8 }
+
+
+snAgentBrdTrafficLeds OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A bit array that contains the value of the
+ front panel traffic LEDs. This is a packed bit string;
+ each LED is encoded into 1 bit for each switch
+ port. The maximum number of ports in one chassis
+ is 24 that means 24 Ports Traffic LEDs. The expansion port
+ number always begins from the last main port number.
+ The following shows the meaning of each bit for each
+ switch port:
+
+ bit value meaning
+ -------- ---------
+ 0 off (no traffic)
+ 1 on (traffic)
+
+ The bitmap of LEDs are as following:
+
+ (Port1) (Port4) (Port8)
+ Bit (Bit0) (Bit3) (Bit7)
+ Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
+ Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
+ Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
+ --------"
+ ::= { snAgentBrdEntry 9 }
+
+
+snAgentBrdMediaLeds OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A bit array that contains the value of the
+ front panel media LEDs. This is a packed bit string;
+ each LED is encoded into 1 bit for each switch port.
+ The maximum number of ports in one chassis is 24
+ that means 24 Ports Media LEDs. The expansion port
+ number always begins from the last main port number.
+ The following shows the meaning of each bit for each
+ switch port:
+
+ bit value meaning
+ --------- -------
+ 0 half duplex
+ 1 full duplex
+
+ The bitmap of LEDs are as following:
+ (Port1) (Port4) (Port8)
+ Bit (Bit0) (Bit3) (Bit7)
+ Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
+ Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
+ Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
+ ---------"
+ ::= { snAgentBrdEntry 10 }
+
+
+
+snAgentBrdSpeedLeds OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A bit array that contains the value of the
+ front panel media LEDs. This is a packed bit string;
+ each LED is encoded into 1 bit for each switch port.
+ The maximum number of ports in one chassis is 24
+ that means 24 Ports Speed LEDs. The expansion port
+ number always begins from the last main port number.
+ The following shows the meaning of each bit for each
+ switch port:
+
+ bit value meaning
+ --------- -------
+ 0 10 MBit
+ 1 100 MBit
+
+ The bitmap of LEDs are as following:
+ (Port1) (Port4) (Port8)
+ Bit (Bit0) (Bit3) (Bit7)
+ Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
+ Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
+ Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
+ ---------"
+ ::= { snAgentBrdEntry 11 }
+
+snAgentBrdModuleStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ moduleEmpty(0),
+ moduleGoingDown(2),
+ moduleRejected(3),
+ moduleBad(4),
+ moduleComingUp(9),
+ moduleRunning(10)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "By default, this mode is set to notActivated(0).
+ moduleEmpty(0) ......... The slot of the chassis is empty.
+ moduleGoingDown(2) ..... The module is going down.
+ moduleRejected(3) ...... The module is being rejected due to wrong configuration.
+ moduleBad(4) ........... The module Hardware is bad.
+ moduleComingUp(9) ...... The module is in power-up cycle.
+ moduleRunning(10) ....... The module is running."
+ ::= { snAgentBrdEntry 12 }
+
+snAgentBrdRedundantStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ active(2),
+ standby(3),
+ crashed(4),
+ comingUp(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The redundant status of a module. Non-management module always
+ returns other(1). Management module returns the rest of the
+ states."
+ ::= { snAgentBrdEntry 13 }
+
+snAgentBrdAlarmLeds OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A bit array that contains the value of the
+ front panel media LEDs (for POS Module Only). This is a packed bit string;
+ each LED is encoded into 1 bit for each switch port.
+ The maximum number of ports in one chassis is 24
+ that means 24 Ports Speed LEDs. The expansion port
+ number always begins from the last main port number.
+ The following shows the meaning of each bit for each
+ switch port:
+
+ bit value meaning
+ --------- -------
+ 0 no alarm
+ 1 alarm
+
+ The bitmap of LEDs are as following:
+ (Port1) (Port4) (Port8)
+ Bit (Bit0) (Bit3) (Bit7)
+ Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
+ Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
+ Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
+ ---------"
+ ::= { snAgentBrdEntry 14 }
+
+
+snAgentBrdTxTrafficLeds OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A bit array that contains the value of the
+ front panel transmit traffic LEDs (for POS Module Only). This is a packed bit string;
+ each LED is encoded into 1 bit for each switch
+ port. The maximum number of ports in one chassis
+ is 24 that means 24 Ports Transmit Traffic LEDs. The expansion port
+ number always begins from the last main port number.
+ The following shows the meaning of each bit for each
+ switch port:
+
+ bit value meaning
+ -------- ---------
+ 0 off (no transmit traffic)
+ 1 on (transmit traffic)
+
+ The bitmap of LEDs are as following:
+
+ (Port1) (Port4) (Port8)
+ Bit (Bit0) (Bit3) (Bit7)
+ Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
+ Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
+ Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
+ --------"
+ ::= { snAgentBrdEntry 15 }
+
+snAgentBrdRxTrafficLeds OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A bit array that contains the value of the
+ front panel receive traffic LEDs (for POS Module Only). This is a packed bit string;
+ each LED is encoded into 1 bit for each switch
+ port. The maximum number of ports in one chassis
+ is 24 that means 24 Ports Receive Traffic LEDs. The expansion port
+ number always begins from the last main port number.
+ The following shows the meaning of each bit for each
+ switch port:
+
+ bit value meaning
+ -------- ---------
+ 0 off (no receive traffic)
+ 1 on (receive traffic)
+
+ The bitmap of LEDs are as following:
+
+ (Port1) (Port4) (Port8)
+ Bit (Bit0) (Bit3) (Bit7)
+ Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
+ Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
+ Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
+ --------"
+ ::= { snAgentBrdEntry 16 }
+
+-- Trap Receiver Table
+
+
+snAgTrpRcvrTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnAgTrpRcvrEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of managers which to send traps."
+ ::= { snAgentTrp 1 }
+
+snAgTrpRcvrEntry OBJECT-TYPE
+ SYNTAX SnAgTrpRcvrEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A row in the trap receiver table.
+ The column snAgTrpRcvrStatus is used to create
+ and delete rows in the table. Creation requires
+ a SET PDU with objects snAgTrpRcvrIndex,
+ snAgTrpRcvrIpAddr, snAgTrpRcvrComm and
+ snAgTrpRcvrStatus."
+ INDEX { snAgTrpRcvrIndex }
+ ::= { snAgTrpRcvrTable 1 }
+
+SnAgTrpRcvrEntry ::= SEQUENCE {
+ snAgTrpRcvrIndex
+ INTEGER,
+ snAgTrpRcvrIpAddr
+ IpAddress,
+ snAgTrpRcvrComm
+ OCTET STRING,
+ snAgTrpRcvrStatus
+ INTEGER
+ }
+
+snAgTrpRcvrIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..10)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Trap Receiver Table."
+ ::= { snAgTrpRcvrEntry 1 }
+
+snAgTrpRcvrIpAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The ip address for
+ SNMP manager that is to receive the trap."
+ ::= { snAgTrpRcvrEntry 2 }
+
+snAgTrpRcvrComm OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(0..32))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Community string to use."
+ ::= { snAgTrpRcvrEntry 3 }
+
+
+snAgTrpRcvrStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ valid(2),
+ delete(3),
+ create(4),
+ ignore(5)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object is used to create and
+ delete rows in the table and control
+ if they are used. The values
+ that can be written are:
+ ignore(5)...don't use this entry to
+ send traps to at this time
+ delete(3)...deletes the row
+ create(4)...creates a new row
+
+ If the row exists, then a SET with
+ value of create(5) returns error
+ 'badValue'. Deleted rows go away
+ immediately. The following values
+ can be returned on reads:
+ other(1)....some other case
+ valid(2)....the row exists and is valid
+ ignore(5)...don't use this entry to
+ send traps to at this time"
+ ::= { snAgTrpRcvrEntry 4 }
+
+
+-- Boot Sequence Table
+
+
+snAgBootSeqTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnAgBootSeqEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of image load sequnce instructions to the boot code.
+ Boot code will start from instruction of the first valid entry
+ to load the image. If failed, it will use the second valid
+ entry and so on, until a succesful load has completed. Each
+ entry must have an unique instruction, duplicate instructions
+ will be rejected."
+ ::= { snAgentBoot 1 }
+
+snAgBootSeqEntry OBJECT-TYPE
+ SYNTAX SnAgBootSeqEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A row in the boot sequence table."
+ INDEX { snAgBootSeqIndex }
+ ::= { snAgBootSeqTable 1 }
+
+SnAgBootSeqEntry ::= SEQUENCE {
+ snAgBootSeqIndex
+ INTEGER,
+ snAgBootSeqInstruction
+ INTEGER,
+ snAgBootSeqIpAddr
+ IpAddress,
+ snAgBootSeqFilename
+ DisplayString,
+ snAgBootSeqRowStatus
+ INTEGER
+ }
+
+snAgBootSeqIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..4)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the boot sequence table."
+ ::= { snAgBootSeqEntry 1 }
+
+snAgBootSeqInstruction OBJECT-TYPE
+ SYNTAX INTEGER {
+ fromPrimaryFlash(1),
+ fromSecondaryFlash(2),
+ fromTftpServer(3),
+ fromBootpServer(4) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The instruction for the boot code."
+ ::= { snAgBootSeqEntry 2 }
+
+snAgBootSeqIpAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The ip address of the TFTP server if snAgBootSeqInstruction
+ was set to 'fromTftpServer'; otherwise, this object is not
+ used in any other boot instruction."
+ ::= { snAgBootSeqEntry 3 }
+
+snAgBootSeqFilename OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..32))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The image filename on the TFTP server if snAgBootSeqInstruction
+ was set to 'fromTftpServer'; otherwise, this object is not
+ used in any other boot instruction."
+ ::= { snAgBootSeqEntry 4 }
+
+snAgBootSeqRowStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ valid(2),
+ delete(3),
+ create(4) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "To create or delete a boot sequence table entry."
+ ::= { snAgBootSeqEntry 5 }
+
+--- Encoded Octet Strings for the Configuration File Transfer
+
+
+snAgCfgEosTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnAgCfgEosEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table represents the fragmented Configuration File data packet
+ with checksum include in each rows of this table. A SNMP-SET
+ represents configuration file download, and a SNMP-GET represents
+ configuration file upload. This action is only if the SNMP-SET of
+ snAgCfgLoad command is sent along with this table consecutively. The
+ applicable snAgCfgLoad command value is as followings:
+ uploadFromFlashToNMS(23),
+ downloadToFlashFromNMS(24),
+ uploadFromDramToNMS(25),
+ downloadToDramFromNMS(26)."
+ ::= { snAgCfgEos 1 }
+
+
+snAgCfgEosEntry OBJECT-TYPE
+ SYNTAX SnAgCfgEosEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An EOS row in the table of encoded octet strings for table
+ snAgCfgEosTable. "
+ INDEX { snAgCfgEosIndex }
+ ::= { snAgCfgEosTable 1 }
+
+
+
+SnAgCfgEosEntry ::=
+ SEQUENCE {
+ snAgCfgEosIndex
+ INTEGER,
+ snAgCfgEosPacket
+ OCTET STRING,
+ snAgCfgEosChkSum
+ INTEGER
+ }
+
+
+snAgCfgEosIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Each VLAN EOS Buffer Identifier have a multiple
+ VLAN table entries."
+ ::= { snAgCfgEosEntry 1 }
+
+snAgCfgEosPacket OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(0..1000))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An encoded octet string. On reads it contains an integral
+ number of configuration file data packets. The size
+ of each encoded octet string is less than or equal to 1400
+ bytes."
+ ::= { snAgCfgEosEntry 2 }
+
+
+snAgCfgEosChkSum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A checksum of each configuration file data packet."
+ ::= { snAgCfgEosEntry 3 }
+
+
+-- Stackable Management Group
+
+snStackGen OBJECT IDENTIFIER ::= { snStack 1 }
+snStackSecSwitchInfo OBJECT IDENTIFIER ::= { snStack 2 }
+
+-- MIB Objects
+
+
+-- General Stackable Management Information
+
+snStackPriSwitchMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Stackable Management Primary Switch mode
+ either enabled or disabled and the default is
+ disabled mode.
+ enabled(1)...........primary switch enabled
+ disabled(0)..........primary switch disabled"
+ ::= { snStackGen 1 }
+
+snStackMaxSecSwitch OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Maximum Secondary Switches are allowed in the
+ Stackable Management Group."
+ ::= { snStackGen 2 }
+
+snStackTotalSecSwitch OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Total Secondary Switches currently connected to the
+ Stackable Management Group."
+ ::= { snStackGen 3 }
+
+snStackSyncAllSecSwitch OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ invalid(1),
+ device(2),
+ global(3),
+ local(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Synchronize all the secondary switches in the
+ Stackable Management Group with the following commands.
+ device(2)...........device related parameters.
+ global(3)...........global parameters.
+ local(4)............local parameters.
+ The return result of the above commands are either
+ normal(0)...........normal condition.
+ invalid(1)...........invalid result."
+ ::= { snStackGen 4 }
+
+snStackSmSlotIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..8)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Slot 0 is the Master slot and Slot 1-8 are slaves.
+ All the slot-based MIB data can be retrieved with respect to
+ this slot index such as snChassis global MIB. "
+ ::= { snStackGen 5 }
+
+snStackFmpSetProcess OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ pending(1),
+ failure(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "normal(0) - The set process is either in an idle state or FMP-SET-SUCCESS state.
+ pending(1) - The pending process is waiting for the result of an FMP-SET.
+ failure(2) - The failure result of an FMP-SET."
+ ::= { snStackGen 6 }
+
+
+
+
+-- Stackable Management Secondary Switch Information Table
+
+
+snStackSecSwitchTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnStackSecSwitchEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "If snSwGroupOperMode is configured as basic mode
+ which is VLAN by Port, Layer2 switching,
+ then this table is valid. Each VLAN switch port
+ could have a number of VLAN IDs."
+ ::= { snStackSecSwitchInfo 1 }
+
+
+snStackSecSwitchEntry OBJECT-TYPE
+ SYNTAX SnStackSecSwitchEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the Stackable Management Secondary Switch
+ Information table."
+ INDEX {
+ snStackSecSwitchIndex
+ }
+ ::= { snStackSecSwitchTable 1 }
+
+
+SnStackSecSwitchEntry ::= SEQUENCE {
+ snStackSecSwitchIndex
+ INTEGER,
+ snStackSecSwitchSlotId
+ INTEGER,
+ snStackSecSwitchPortCnts
+ INTEGER,
+ snStackSecSwitchEnabled
+ INTEGER,
+ snStackSecSwitchAck
+ INTEGER,
+ snStackSecSwitchMacAddr
+ MacAddress,
+ snStackSecSwitchSyncCmd
+ INTEGER,
+ snStackSecSwitchIpAddr
+ IpAddress,
+ snStackSecSwitchSubnetMask
+ IpAddress,
+ snStackSecSwitchCfgCmd
+ INTEGER
+ }
+
+snStackSecSwitchIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..26)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The secondary switch index must not be greater than the snStackMaxSecSwitch."
+ ::= { snStackSecSwitchEntry 1 }
+
+
+snStackSecSwitchSlotId OBJECT-TYPE
+ SYNTAX INTEGER (1..26)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The secondary switch slot ID must be set before the Configuration
+ command sent from the primary switch to the secondary switch
+ either manually or automatically - snStackSecSwitchCfgCmd."
+ ::= { snStackSecSwitchEntry 2 }
+
+snStackSecSwitchPortCnts OBJECT-TYPE
+ SYNTAX INTEGER (1..26)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of ports in this secondary switch."
+ ::= { snStackSecSwitchEntry 3 }
+
+snStackSecSwitchEnabled OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The secondary switch has been selected to Stackable Management Group."
+ ::= { snStackSecSwitchEntry 4 }
+
+snStackSecSwitchAck OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The secondary switch has sent reponse to the primary switch."
+ ::= { snStackSecSwitchEntry 5 }
+
+snStackSecSwitchMacAddr OBJECT-TYPE
+ SYNTAX MacAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The secondary switch physical address. The physical address
+ represents a MAC Station."
+ ::= { snStackSecSwitchEntry 6 }
+
+snStackSecSwitchSyncCmd OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ invalid(1),
+ device(2),
+ global(3),
+ local(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Synchronize the secondary switches in the
+ Stackable Management Group with the following commands.
+ device(2)...........device related parameters.
+ global(3)...........global parameters.
+ local(4)............local parameters.
+ The return result of the above commands are either
+ normal(0)...........normal condition.
+ invalid(1)...........invalid result."
+ ::= { snStackSecSwitchEntry 7 }
+
+snStackSecSwitchIpAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The secondary switch IP Address and is used for
+ manual-command of snStackSecSwitchCfgCmd."
+ ::= { snStackSecSwitchEntry 8 }
+
+snStackSecSwitchSubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The secondary switch IP Subnet Mask and is used for
+ manual-command of snStackSecSwitchCfgCmd."
+ ::= { snStackSecSwitchEntry 9 }
+
+snStackSecSwitchCfgCmd OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ invalid(1),
+ auto(2),
+ manual(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "snStackSecSwitchSlotId must be set before the Configuration
+ command sent from the primary switch to the secondary switch
+ either manually or automatically.
+ auto(2)...........auto-configuration command sent.
+ manual(3).........manual-configuration command sent.
+ if manual-mode is used, snStackSecSwitchIpAddr
+ and snStackSecSwitchSubnetMask must be
+ first set before this command is sent.
+ The return result of the above commands are either
+ normal(0)...........normal condition.
+ invalid(1)..........invalid result."
+ ::= { snStackSecSwitchEntry 10 }
+
+-- System Logging Group
+
+snAgSysLogGbl OBJECT IDENTIFIER ::= { snAgentLog 1 }
+
+snAgSysLogGblEnable OBJECT-TYPE
+ SYNTAX INTEGER { disabled(0), enabled(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enable/disable system logging."
+ DEFVAL { enabled }
+ ::= { snAgSysLogGbl 1 }
+
+snAgSysLogGblBufferSize OBJECT-TYPE
+ SYNTAX INTEGER (1..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The number of dynamic system logging entries."
+ DEFVAL { 50 }
+ ::= { snAgSysLogGbl 2 }
+
+snAgSysLogGblClear OBJECT-TYPE
+ SYNTAX INTEGER { normal(0), clearAll(1), clearDynamic(2), clearStatic(3) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Clear dynamic and/or static system logging buffers."
+ ::= { snAgSysLogGbl 3 }
+
+snAgSysLogGblCriticalLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Filter events going to the logging buffer. This is a packed
+ bit string object of which each bit has the following meaning:
+ (bit 0 is the least significant bit).
+
+ bit position meaning
+ ------------ -------
+ 8-31 reserved
+ 7 Warning (warning conditions)
+ 6 Notification (normal but significant conditions)
+ 5 Informational (informational messages)
+ 4 Error (error conditions)
+ 3 Emergency (system is unusable)
+ 2 Debugging (debugging messages)
+ 1 Critical (critical conditions)
+ 0 Alert (immediate action needed)
+
+ Setting a critical level bit to 1 makes the logging buffer
+ accept the corresponding event. Resetting a critical level
+ bit to 0 makes the logging buffer reject the corresponding
+ event."
+ DEFVAL { 255 }
+ ::= { snAgSysLogGbl 4 }
+
+snAgSysLogGblLoggedCount OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number events logged in the system logging buffer."
+ ::= { snAgSysLogGbl 5 }
+
+snAgSysLogGblDroppedCount OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of events dropped."
+ ::= { snAgSysLogGbl 6 }
+
+snAgSysLogGblFlushedCount OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of times that the system logging buffer was cleared."
+ ::= { snAgSysLogGbl 7 }
+
+snAgSysLogGblOverrunCount OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of times that the system logging buffer was wrapped
+ around."
+ ::= { snAgSysLogGbl 8 }
+
+snAgSysLogGblServer OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "IP address of syslog server."
+ ::= { snAgSysLogGbl 9 }
+
+snAgSysLogGblFacility OBJECT-TYPE
+ SYNTAX INTEGER {
+ kern(1),
+ user(2),
+ mail(3),
+ daemon(4),
+ auth(5),
+ syslog(6),
+ lpr(7),
+ news(8),
+ uucp(9),
+ sys9(10),
+ sys10(11),
+ sys11(12),
+ sys12(13),
+ sys13(14),
+ sys14(15),
+ cron(16),
+ local0(17),
+ local1(18),
+ local2(19),
+ local3(20),
+ local4(21),
+ local5(22),
+ local6(23),
+ local7(24)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Facility code."
+ DEFVAL { user }
+ ::= { snAgSysLogGbl 10 }
+
+-- Dynamic System Logging Buffer Table
+
+snAgSysLogBufferTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnAgSysLogBufferEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Dynamic system logging buffer table."
+ ::= { snAgentLog 2 }
+
+snAgSysLogBufferEntry OBJECT-TYPE
+ SYNTAX SnAgSysLogBufferEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A row in the dynamic system logging buffer table."
+ INDEX { snAgSysLogBufferIndex }
+ ::= { snAgSysLogBufferTable 1 }
+
+SnAgSysLogBufferEntry ::= SEQUENCE {
+ snAgSysLogBufferIndex
+ INTEGER,
+ snAgSysLogBufferTimeStamp
+ TimeTicks,
+ snAgSysLogBufferCriticalLevel
+ INTEGER,
+ snAgSysLogBufferMessage
+ DisplayString,
+ snAgSysLogBufferCalTimeStamp
+ DisplayString
+ }
+
+snAgSysLogBufferIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..100)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the dynamic system logging buffer table."
+ ::= { snAgSysLogBufferEntry 1 }
+
+snAgSysLogBufferTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A time stamp when the event is logged."
+ ::= { snAgSysLogBufferEntry 2 }
+
+snAgSysLogBufferCriticalLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ alert(2),
+ critical(3),
+ debugging(4),
+ emergency(5),
+ error(6),
+ informational(7),
+ notification(8),
+ warning(9) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The critical level of this event."
+ ::= { snAgSysLogBufferEntry 3 }
+
+snAgSysLogBufferMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system logging message."
+ ::= { snAgSysLogBufferEntry 4 }
+
+snAgSysLogBufferCalTimeStamp OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A time stamp when the event is logged. This object returns
+ a NULL terminated time stamp string if the system calendar
+ time was set. It returns a zero length string if the system
+ calendar time was not set."
+ ::= { snAgSysLogBufferEntry 5 }
+
+
+-- Static System Logging Buffer Table
+
+snAgStaticSysLogBufferTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnAgStaticSysLogBufferEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Static system logging buffer table."
+ ::= { snAgentLog 3 }
+
+snAgStaticSysLogBufferEntry OBJECT-TYPE
+ SYNTAX SnAgStaticSysLogBufferEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A row in the static system logging buffer table."
+ INDEX { snAgStaticSysLogBufferIndex }
+ ::= { snAgStaticSysLogBufferTable 1 }
+
+SnAgStaticSysLogBufferEntry ::= SEQUENCE {
+ snAgStaticSysLogBufferIndex
+ INTEGER,
+ snAgStaticSysLogBufferTimeStamp
+ TimeTicks,
+ snAgStaticSysLogBufferCriticalLevel
+ INTEGER,
+ snAgStaticSysLogBufferMessage
+ DisplayString,
+ snAgStaticSysLogBufferCalTimeStamp
+ DisplayString
+ }
+
+snAgStaticSysLogBufferIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..100)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the static system logging buffer table."
+ ::= { snAgStaticSysLogBufferEntry 1 }
+
+snAgStaticSysLogBufferTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A time stamp when the event is logged."
+ ::= { snAgStaticSysLogBufferEntry 2 }
+
+snAgStaticSysLogBufferCriticalLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ alert(2),
+ critical(3),
+ debugging(4),
+ emergency(5),
+ error(6),
+ informational(7),
+ notification(8),
+ warning(9) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The critical level of this event."
+ ::= { snAgStaticSysLogBufferEntry 3 }
+
+snAgStaticSysLogBufferMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system logging message."
+ ::= { snAgStaticSysLogBufferEntry 4 }
+
+snAgStaticSysLogBufferCalTimeStamp OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A time stamp when the event is logged. This object returns
+ a NULL terminated time stamp string if the system calendar
+ time was set. It returns a zero length string if the system
+ calendar time was not set."
+ ::= { snAgStaticSysLogBufferEntry 5 }
+
+
+-- Agent System Parameters Configuration Table
+
+
+snAgentSysParaConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnAgentSysParaConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of Agent of each board."
+ ::= { snAgentSysParaConfig 1 }
+
+snAgentSysParaConfigEntry OBJECT-TYPE
+ SYNTAX SnAgentSysParaConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A row in the Agent System Parameters Configuation table."
+ INDEX { snAgentSysParaConfigIndex }
+ ::= { snAgentSysParaConfigTable 1 }
+
+SnAgentSysParaConfigEntry ::= SEQUENCE {
+ snAgentSysParaConfigIndex
+ INTEGER,
+ snAgentSysParaConfigDescription
+ DisplayString,
+ snAgentSysParaConfigMin
+ INTEGER,
+ snAgentSysParaConfigMax
+ INTEGER,
+ snAgentSysParaConfigDefault
+ INTEGER,
+ snAgentSysParaConfigCurrent
+ INTEGER
+ }
+
+snAgentSysParaConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Agent System Parameters Configuation Table."
+ ::= { snAgentSysParaConfigEntry 1 }
+
+snAgentSysParaConfigDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The main board description string."
+ ::= { snAgentSysParaConfigEntry 2 }
+
+snAgentSysParaConfigMin OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum value of this Agent System Parameter."
+ ::= { snAgentSysParaConfigEntry 3 }
+
+snAgentSysParaConfigMax OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum value of this Agent System Parameter."
+ ::= { snAgentSysParaConfigEntry 4 }
+
+snAgentSysParaConfigDefault OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The default value of this Agent System Parameter."
+ ::= { snAgentSysParaConfigEntry 5 }
+
+snAgentSysParaConfigCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The current configurated value of this Agent System Parameter."
+ ::= { snAgentSysParaConfigEntry 6 }
+
+
+-- Agent Configured Module Table
+
+
+snAgentConfigModuleTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnAgentConfigModuleEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of each configured module information."
+ ::= { snAgentConfigModule 1 }
+
+snAgentConfigModuleEntry OBJECT-TYPE
+ SYNTAX SnAgentConfigModuleEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A row in the Agent Configured Module table."
+ INDEX { snAgentConfigModuleIndex }
+ ::= { snAgentConfigModuleTable 1 }
+
+SnAgentConfigModuleEntry ::= SEQUENCE {
+ snAgentConfigModuleIndex
+ INTEGER,
+ snAgentConfigModuleType
+ INTEGER,
+ snAgentConfigModuleRowStatus
+ INTEGER
+ }
+
+snAgentConfigModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..8)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Agent Configured Module Table."
+ ::= { snAgentConfigModuleEntry 1 }
+
+snAgentConfigModuleType OBJECT-TYPE
+ SYNTAX INTEGER {
+ bi8PortGigManagementModule(0),
+ bi4PortGigManagementModule(1),
+ bi16PortCopperManagementModule(2),
+ bi4PortGigModule(3),
+ fi2PortGigManagementModule(4),
+ fi4PortGigManagementModule(5),
+ bi8PortGigCopperManagementModule(6),
+ fi8PortGigManagementModule(7),
+ bi8PortGigModule(8),
+ bi24PortCopperModule(10),
+ fi24PortCopperModule(11),
+ bi16Port100FXModule(12),
+ bi8Port100FXModule(13),
+ bi8PortGigCopperModule(14),
+ bi2PortGigManagementModule(18),
+ bi24Port100FXModule(19),
+ bi0PortManagementModule(20),
+ pos622MbsModule(21),
+ pos155MbsModule(22),
+ bi2PortGigModule(23),
+ bi2PortGigCopperModule(24),
+ fi2PortGigModule(25),
+ fi4PortGigModule(26),
+ fi8PortGigModule(27),
+ fi8PortGigCopperModule(28),
+ fi8PortGigCopperManagementModule(29),
+ pos155Mbs2PModule(30),
+ fi2PortGigCopperManagementModule(31),
+ fi4PortGigCopperManagementModule(32),
+ bi4PortGigCopperManagementModule(33),
+ bi2PortGigCopperManagementModule(34)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Configured Module Type."
+ ::= { snAgentConfigModuleEntry 2 }
+
+
+snAgentConfigModuleRowStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ valid(2),
+ delete(3),
+ create(4) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "To create or delete a configured module table entry."
+ ::= { snAgentConfigModuleEntry 3 }
+
+-- Agent User Access Group
+
+
+snAgentUserGbl OBJECT IDENTIFIER ::= { snAgentUser 1 }
+
+snAgentUserMaxAccnt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Maximum number of user account entries can be configured."
+ ::= { snAgentUserGbl 1 }
+
+
+-- Agent User Account Table
+
+
+snAgentUserAccntTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SnAgentUserAccntEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of user account information."
+ ::= { snAgentUser 2 }
+
+snAgentUserAccntEntry OBJECT-TYPE
+ SYNTAX SnAgentUserAccntEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A row in the Agent User table."
+ INDEX { snAgentUserAccntName }
+ ::= { snAgentUserAccntTable 1 }
+
+SnAgentUserAccntEntry ::= SEQUENCE {
+ snAgentUserAccntName
+ DisplayString,
+ snAgentUserAccntPassword
+ DisplayString,
+ snAgentUserAccntEncryptCode
+ INTEGER,
+ snAgentUserAccntPrivilege
+ INTEGER,
+ snAgentUserAccntRowStatus
+ INTEGER
+ }
+
+snAgentUserAccntName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..48))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The user name."
+ ::= { snAgentUserAccntEntry 1 }
+
+snAgentUserAccntPassword OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..48))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The user password."
+ ::= { snAgentUserAccntEntry 2 }
+
+snAgentUserAccntEncryptCode OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The password encryption method code."
+ ::= { snAgentUserAccntEntry 3 }
+
+snAgentUserAccntPrivilege OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The user privilege."
+ ::= { snAgentUserAccntEntry 4 }
+
+snAgentUserAccntRowStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ valid(2),
+ delete(3),
+ create(4),
+ modify(5) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "To create or delete a user account table entry."
+ ::= { snAgentUserAccntEntry 5 }
+
+-- Agent Redundant Group
+
+
+snAgentRedunGbl OBJECT IDENTIFIER ::= { snAgentRedundant 1 }
+
+snAgentRedunActiveMgmtMod OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Slot number of the active management module. Setting
+ this object does not take effect immediately. Saving
+ configuration data to flash storage and reboot the
+ system are required to take effect. Setting a value of 0
+ requests the system to auto-select an active management
+ module after power up."
+ DEFVAL { 0 }
+ ::= { snAgentRedunGbl 1 }
+
+snAgentRedunSyncConfig OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Frequency of the backup management module copying the
+ configuration data from the active management module.
+ Each unit is 1 second. Setting a value 0 will disable
+ the synchronization copy. Setting a negative value will
+ initiate the synchronization copy once immediately."
+ DEFVAL { 10 }
+ ::= { snAgentRedunGbl 2 }
+
+snAgentRedunBkupCopyBootCode OBJECT-TYPE
+ SYNTAX INTEGER { disabled(0), enabled(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "If enabled(1), the backup management module copies the boot code
+ from the active management module to its boot code flash storage
+ after power up, and whenever the active management module's boot
+ code is updated. The backup management module does not copy if
+ both boot codes were identical."
+ DEFVAL { disabled }
+ ::= { snAgentRedunGbl 3 }
+
+snAgentEnableMgmtModRedunStateChangeTrap OBJECT-TYPE
+ SYNTAX INTEGER { disabled(0), enabled(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the SNMP agent process is permitted to
+ generate management module redundancy state change traps."
+ DEFVAL { enabled }
+ ::= { snAgentRedunGbl 4 }
+
+snAgentRedunBkupBootLoad OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ operationError(17),
+ downloadBackup(20)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Action object to down load a new boot code from boot flash storage
+ of the active management module to the backup management module.
+ The following are returned values from get operation:
+ normal(1)............no operation
+ operationError(17)...error codes
+
+ The following are input values from set operation:
+ downloadBackup(20)...download the boot code from the active
+ management module to the backup management
+ module
+
+ Any set operation is rejected during loading until error
+ or normal state is reached."
+ ::= { snAgentRedunGbl 5 }
+
+snAgentRedunSwitchOver OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ reset(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "To force a switch-over from standby to active state
+ if the backup management module exists in a chassis."
+ ::= { snAgentRedunGbl 6 }
+
+END