+ HUAWEI-MPLSOAM-PS-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ hwMplsOam
+ FROM HUAWEI-MPLSOAM-MIB
+ InterfaceIndex
+ FROM IF-MIB
+ OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
+ FROM SNMPv2-CONF
+ IpAddress, Integer32, Unsigned32, OBJECT-TYPE, NOTIFICATION-TYPE
+ FROM SNMPv2-SMI
+ RowStatus, TruthValue
+ FROM SNMPv2-TC;
+
+
+
+--
+-- Node definitions
+--
+
+ hwMplsOamPs OBJECT IDENTIFIER ::= { hwMplsOam 1 }
+
+
+ hwMplsPsObjects OBJECT IDENTIFIER ::= { hwMplsOamPs 3 }
+
+
+ hwMplsPsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HwMplsPsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table specifies per-protection-group MPLS PS
+ capability and associated information.
+ "
+ ::= { hwMplsPsObjects 1 }
+
+
+ hwMplsPsEntry OBJECT-TYPE
+ SYNTAX HwMplsPsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in this table is created by an LSR for every
+ protection group capable of supporting mpls ps."
+ INDEX { hwMplsPsIndex }
+ ::= { hwMplsPsTable 1 }
+
+
+ HwMplsPsEntry ::=
+ SEQUENCE {
+ hwMplsPsIndex
+ Unsigned32,
+ hwMplsPsType
+ Integer32,
+ hwMplsPsWorkTunnName
+ OCTET STRING,
+ hwMplsPsWorkTunnId
+ Integer32,
+ hwMplsPsProtectTunnName
+ OCTET STRING,
+ hwMplsPsProtectTunnId
+ Integer32,
+ hwMplsPsRevertiveMode
+ Integer32,
+ hwMplsPsWTR
+ Integer32,
+ hwMplsPsHoldOff
+ Integer32,
+ hwMplsPsSwitchCondition
+ Integer32,
+ hwMplsPsWorkTunnelState
+ Integer32,
+ hwMplsPsProtTunnelState
+ Integer32,
+ hwMplsPsSwitchResult
+ Integer32,
+ hwMplsPsCfgType
+ Integer32,
+ hwMplsPsCfgProtectTunnId
+ Integer32,
+ hwMplsPsCfgRevertiveMode
+ Integer32,
+ hwMplsPsCfgWTR
+ Integer32,
+ hwMplsPsCfgHoldOff
+ Integer32,
+ hwMplsPsRowStatus
+ RowStatus
+ }
+
+ hwMplsPsIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is a unique index for an entry in the mplspsEntry.
+
+ "
+ ::= { hwMplsPsEntry 1 }
+
+
+ hwMplsPsType OBJECT-TYPE
+ SYNTAX Integer32 (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of protection switch,can be 1:1,1+1,shared mesh,
+ packet 1+1,the default choice is 1:1.
+ In the 1+1 architecture type, a protection LSP is dedicated to
+ each working LSP with the working LSP bridged onto the
+ protection LSP at the source of the protection domain.
+ The traffic on working and protection LSPs is transmitted
+ simultaneously to the sink of the protection domain,
+ where a selection between the working and protection LSP is
+ made, based on some predetermined criteria, such as defect
+ indication.
+ In the 1:1 architecture type, a protection LSP is dedicated to
+ each working LSP. The working traffic is transmitted either by
+ working or protection LSP.
+ In the shared mesh architecture type, possible sharing of
+ protection capacity between disjoint link, node in the network
+ is achieved while guaranteeing recovery from a single failure.
+ In the packet 1+1 architecture type, the traffic is transmitted
+ simultaneously onto two possibly disjoint routed LSPs to the
+ sink of the protection domain. Each pair of duplicate
+ transmitted packets is assigned the same identifier (sequence
+ number) but distinct from the other pairs of duplicate packets.
+ At the sink of the protection domain packet level selection
+ mechanism is employed to select one of the two possibly
+ received copies of each packet.
+ 1: 1:1 protection switching,;
+ 2: 1+1 protection switching;
+ 3: shared mesh protection swiching;
+ 4: packet 1+1 protection switching.
+ "
+ ::= { hwMplsPsEntry 2 }
+
+
+ hwMplsPsWorkTunnName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The name of work-tunnel."
+ ::= { hwMplsPsEntry 3 }
+
+
+ hwMplsPsWorkTunnId OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Work-tunnel id(session-tunnel-id)."
+ ::= { hwMplsPsEntry 4 }
+
+
+ hwMplsPsProtectTunnName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of protect-tunnel."
+ ::= { hwMplsPsEntry 5 }
+
+
+ hwMplsPsProtectTunnId OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Protect-tunnel id(session-tunnel-id)."
+ ::= { hwMplsPsEntry 6 }
+
+
+ hwMplsPsRevertiveMode OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Revertive mode is a protection switching mode where revertive
+ action (switch back to the working LSP) is taken after the
+ working LSP is repaired.And switching does not occur in a
+ non-revertive mode.
+ 1: revertive;
+ 2: non-revertive;
+ "
+ ::= { hwMplsPsEntry 7 }
+
+
+ hwMplsPsWTR OBJECT-TYPE
+ SYNTAX Integer32 (0..60)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Wait to Restore timer is only applicable for the revertive mode
+ and applies to a working LSP,It prevents reversion back to
+ select the working LSP until the Wait to Restore timer has
+ expired.The default value is 12 minutes.step is 30s."
+ ::= { hwMplsPsEntry 8 }
+
+
+ hwMplsPsHoldOff OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time between declaration of signal degrade or signal fail,
+ and the initialization of the protection switching algorithm.
+ step is 100ms.maximum is 10s."
+ ::= { hwMplsPsEntry 9 }
+
+
+ hwMplsPsSwitchCondition OBJECT-TYPE
+ SYNTAX Integer32 (1..9)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The current switch condition of the protection group.
+ 1: clear,This command clears all of the externally
+ initiated switch commands listed below;
+ 2: lockout of protection,Fix the selector position on the
+ working LSP,Prevents the selector from switching to the
+ protection LSP when it is selecting the working LSP.
+ Switches the selector from the protection to the working LSP
+ when it is selecting the protection LSP;
+ 3: forced protection,Switches the selector from the working LSP
+ to the protection LSP (unless a higher priority switch
+ request (i.e., LoP) is in effect);
+ 4: signal fail,for 1:1,Signal Fail (SF) is declared when the
+ source of the protection domain enters the Defect State by
+ receiving a BDI packet (from the return LSP or out of band).
+ 5: manual switch for working-lsp,Switches the selector from the
+ working LSP to the protection LSP (unless an equal or higher
+ priority switch request (i.e., LoP, FS, SF or MS) is in
+ effect);
+ 6: manual switch for protection-lsp,Switches the selector from
+ the protection LSP to the working LSP (unless an equal or
+ higher priority switch request (i.e., LoP, FS, SF or MS) is
+ in effect).
+ 7: WTR-timer;
+ 8: HoldOff-timer;
+ 9: Others;
+ The pripority of the commands are:
+ clear > lockout of protection > force switch > manual switch for working
+ lsp = manual switch for protection lsp"
+ ::= { hwMplsPsEntry 10 }
+
+
+ hwMplsPsWorkTunnelState OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state of working tunnel state in one protection group,
+ whether it is in detection,
+ 1: it is outof defect
+ 2: it enters defect
+ "
+ ::= { hwMplsPsEntry 11 }
+
+
+ hwMplsPsProtTunnelState OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The state of protection tunnel state in one protection group,
+ whether it is in detection,
+ 1: it is outof defect
+ 2: it enters defect"
+ ::= { hwMplsPsEntry 12 }
+
+
+ hwMplsPsSwitchResult OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Which tunnel is used to transfer the data stream.
+ 1: working-tunnel
+ 2: protection-tunnel"
+ ::= { hwMplsPsEntry 13 }
+
+
+ hwMplsPsCfgType OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of protection switch which is configured.
+ 1: 1:1
+ 2: 1+1
+ 3: shared mesh
+ 4: packet 1:1"
+ ::= { hwMplsPsEntry 14 }
+
+
+ hwMplsPsCfgProtectTunnId OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Protect-tunnel id(session-tunnel-id)."
+ ::= { hwMplsPsEntry 15 }
+
+
+ hwMplsPsCfgRevertiveMode OBJECT-TYPE
+ SYNTAX Integer32 (1..2)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Revertive mode is a protection switching mode where revertive
+ action (switch back to the working LSP) is taken after the
+ working LSP is repaired.And switching does not occur in a
+ non-revertive mode.
+ 1: revertive;
+ 2: non-revertive;
+
+ "
+ ::= { hwMplsPsEntry 16 }
+
+
+ hwMplsPsCfgWTR OBJECT-TYPE
+ SYNTAX Integer32 (0..60)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Wait to Restore timer is only applicable for the revertive mode
+ and applies to a working LSP,It prevents reversion back to
+ select the working LSP until the Wait to Restore timer has
+ expired.The default value is 12 minutes.step is 30s."
+ ::= { hwMplsPsEntry 17 }
+
+
+ hwMplsPsCfgHoldOff OBJECT-TYPE
+ SYNTAX Integer32 (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The time between declaration of signal degrade or signal fail,
+ and the initialization of the protection switching algorithm.
+ step is 100ms.maximum is 10s."
+ ::= { hwMplsPsEntry 18 }
+
+
+ hwMplsPsRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable is used to create, modify, and
+ delete a row in this table.
+ 1: active
+ 2: not in service
+ 3: not ready
+ 4: create and go
+ 5: create and wait
+ 6: destroy"
+ ::= { hwMplsPsEntry 19 }
+
+
+ hwTunnPsTrapOpen OBJECT-TYPE
+ SYNTAX Unsigned32 (1..2)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "1:enable;
+ 2:disable;"
+ ::= { hwMplsPsObjects 2 }
+
+
+ hwMplsVCPsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HwMplsVCPsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { hwMplsPsObjects 3 }
+
+
+ hwMplsVCPsEntry OBJECT-TYPE
+ SYNTAX HwMplsVCPsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "this table for these commands
+ 1.mpls te protection tunnel XXX
+ 2. mpls te reverse-lsp { lsp-name XXXX | lsr-id X.X.X.X tunnel-id x }
+ 3. mpls te reserved-for-binding "
+ INDEX { hwMplsVCPsIfIndex }
+ ::= { hwMplsVCPsTable 1 }
+
+
+ HwMplsVCPsEntry ::=
+ SEQUENCE {
+ hwMplsVCPsIfIndex
+ InterfaceIndex,
+ hwMplsVCPsTNLBinding
+ TruthValue,
+ hwMplsTeReverseLspName
+ OCTET STRING,
+ hwMplsVcPsRowStatus
+ RowStatus,
+ hwMplsTeReverseLspLsrId
+ IpAddress,
+ hwMplsTeReverseLspTunnId
+ Integer32
+ }
+
+ hwMplsVCPsIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Description.the index of working tunnel interface of Protection group "
+ ::= { hwMplsVCPsEntry 1 }
+
+
+ hwMplsVCPsTNLBinding OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Description.it is used by command ' mpls te reserved-for-binding '"
+ ::= { hwMplsVCPsEntry 2 }
+
+
+ hwMplsTeReverseLspName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Description.it is used for command ' mpls te reverse-lsp lspname'"
+ ::= { hwMplsVCPsEntry 3 }
+
+
+ hwMplsVcPsRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Description.
+ 1: active;
+ 2: notInservice;
+ 3: notReady;
+ 4: CreateAndGo;
+ 5: CreateAndWait;
+ 6: destroy;"
+ ::= { hwMplsVCPsEntry 4 }
+
+
+ hwMplsTeReverseLspLsrId OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Description.it is used for command ' mpls te reverse-lsp lsr-id X.X.X.X tunnel-id XX'"
+ ::= { hwMplsVCPsEntry 5 }
+
+
+ hwMplsTeReverseLspTunnId OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Description.it is used for command ' mpls te reverse-lsp lsr-id X.X.X.X tunnel-id XX'"
+ ::= { hwMplsVCPsEntry 6 }
+
+
+ hwMplsPsNotifications OBJECT IDENTIFIER ::= { hwMplsOamPs 4 }
+
+
+ hwMplsPsSwitchPtoW NOTIFICATION-TYPE
+ OBJECTS { hwMplsPsWorkTunnName, hwMplsPsWorkTunnId, hwMplsPsProtectTunnName, hwMplsPsProtectTunnId, hwMplsPsSwitchResult
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when switching from
+ protection-lsp to working-lsp occured."
+ ::= { hwMplsPsNotifications 1 }
+
+
+ hwMplsPsSwitchWtoP NOTIFICATION-TYPE
+ OBJECTS { hwMplsPsWorkTunnName, hwMplsPsWorkTunnId, hwMplsPsProtectTunnName, hwMplsPsProtectTunnId, hwMplsPsSwitchResult
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated when switching from woking-lsp
+ to protection-lsp occured.
+ "
+ ::= { hwMplsPsNotifications 2 }
+
+
+ hwMplsOamPsConformance OBJECT IDENTIFIER ::= { hwMplsOamPs 100 }
+
+
+ hwMplsOamPsCompliances OBJECT IDENTIFIER ::= { hwMplsOamPsConformance 1 }
+
+
+ hwMplsOamPsGroupCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for mpls oam ps."
+ MODULE -- this module
+ MANDATORY-GROUPS { hwMplsPsGroup, hwMplsVcPsGroup }
+ ::= { hwMplsOamPsCompliances 1 }
+
+
+ hwMplsOamPsGroups OBJECT IDENTIFIER ::= { hwMplsOamPsConformance 2 }
+
+
+ hwMplsPsGroup OBJECT-GROUP
+ OBJECTS { hwMplsPsType, hwMplsPsWorkTunnName, hwMplsPsWorkTunnId, hwMplsPsProtectTunnName, hwMplsPsProtectTunnId,
+ hwMplsPsRevertiveMode, hwMplsPsWTR, hwMplsPsHoldOff, hwMplsPsSwitchCondition, hwMplsPsWorkTunnelState,
+ hwMplsPsProtTunnelState, hwMplsPsSwitchResult, hwMplsPsCfgType, hwMplsPsCfgProtectTunnId, hwMplsPsCfgRevertiveMode,
+ hwMplsPsCfgWTR, hwMplsPsCfgHoldOff, hwMplsPsRowStatus, hwTunnPsTrapOpen, hwMplsVCPsIfIndex,
+ hwMplsPsIndex }
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for mpls oam ps management."
+ ::= { hwMplsOamPsGroups 1 }
+
+
+ hwMplsVcPsGroup OBJECT-GROUP
+ OBJECTS { hwMplsVCPsTNLBinding, hwMplsTeReverseLspName, hwMplsVcPsRowStatus, hwMplsTeReverseLspLsrId, hwMplsTeReverseLspTunnId
+ }
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for mpls oam ps reverse lsp."
+ ::= { hwMplsOamPsGroups 2 }
+
+
+ hwMplsPsNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS { hwMplsPsSwitchPtoW, hwMplsPsSwitchWtoP }
+ STATUS current
+ DESCRIPTION
+ "Description."
+ ::= { hwMplsOamPsGroups 3 }
+
+
+
+ END