summaryrefslogtreecommitdiff
path: root/MIBS/ibm/IMMALERT-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/ibm/IMMALERT-MIB')
-rw-r--r--MIBS/ibm/IMMALERT-MIB1079
1 files changed, 1079 insertions, 0 deletions
diff --git a/MIBS/ibm/IMMALERT-MIB b/MIBS/ibm/IMMALERT-MIB
new file mode 100644
index 0000000..15b76c6
--- /dev/null
+++ b/MIBS/ibm/IMMALERT-MIB
@@ -0,0 +1,1079 @@
+-- ***************************************************************************
+-- ***************************************************************************
+--
+-- File : immalert.mib
+-- Description : Integrated Management Module mib for SNMP alerts
+-- By : IBM
+-- Version : 2.6
+-- Date : July 26, 2011
+--
+--
+-- Copyright (c) 2011 IBM All Rights Reserved.
+--
+--
+-- Contains MIB description for:
+-- This MIB is used by the IMM to generate traps
+-- for Alert conditions detected by the management firmware.
+-- ***************************************************************************
+-- ***************************************************************************
+-- ***************************************************************************
+-- Revisions:
+-- 07/28/2010 Version 2.0
+-- Updated version info for imm2.mib and added portParity and portStopBits since these are supported in IMM2 hardware.
+--
+-- 09/13/2010 Version 2.1
+-- added some Trap Types. Removed a couple of Trap Types. Changed some Trap Type names for consistency.
+--
+-- 10/20/2010 Version 2.2
+-- add additional OIDs required to be sent with each SNMP Trap.
+--
+-- 02/24/2011 Version 2.3
+-- change netfinitySupportProcessor to supportProcessor to be consistent with naming of "ibmProd 158" in other alert MIBs
+--
+-- 03/17/2011 Version 2.4
+-- fix spelling of imm2alertMIB
+--
+-- 07/07/2011 Version 2.5
+-- changes to make mib compatible with IMM1
+--
+-- 07/26/2011 Version 2.6
+-- correction to "Alert Severity Value", range 0..65535
+-- ***************************************************************************
+ IMMALERT-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ OBJECT-TYPE FROM RFC-1212
+ enterprises,
+ Counter, TimeTicks, IpAddress FROM RFC1155-SMI
+ mib-2,
+ DisplayString FROM RFC1213-MIB;
+
+
+ -- MIB for IMM Alerts starts here
+
+
+ ibm OBJECT IDENTIFIER ::= { enterprises 2 }
+
+ -- IBM products group
+
+ ibmProd OBJECT IDENTIFIER ::= { ibm 6 }
+
+ -- IBM Netfinity SP
+
+ supportProcessor OBJECT IDENTIFIER ::= { ibmProd 158 }
+
+ -- IBM IMM Alert
+
+ immalertMIB OBJECT IDENTIFIER ::= { supportProcessor 5 }
+
+ -- the nfspalt generic trap generator group
+
+ immtrapg OBJECT IDENTIFIER ::= { immalertMIB 1 }
+
+ altDateTime OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Timestamp of Local Date and Time when alert was generated"
+ ::= { immtrapg 1 }
+
+ altSpTxtId OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "SP System Identification - Text Identification"
+ ::= { immtrapg 3 }
+
+ altSysUuid OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Host System UUID(Universal Unique ID)"
+ ::= { immtrapg 5 }
+
+ altSysSern OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Host System Serial Number"
+ ::= { immtrapg 6 }
+
+ altPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alert Severity Value
+ - Critical Alert(0)
+ - Non-Critical Alert(2)
+ - System Alert(4)
+ - Recovery(8)"
+ ::= { immtrapg 8 }
+
+ altMsgText OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alert Message Text"
+ ::= { immtrapg 9 }
+
+ altMsgID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alert Message ID"
+ ::= { immtrapg 10 }
+
+ altMsgIDPrefix OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alert Message ID"
+ ::= { immtrapg 11 }
+
+
+ altHostContact OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Host Contact"
+ ::= { immtrapg 12 }
+
+ altHostLocation OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Host Location"
+ ::= { immtrapg 13 }
+
+ altHostRoomID OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Host Location - Room ID"
+ ::= { immtrapg 14 }
+
+ altHostRackID OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Host Location - Rack ID"
+ ::= { immtrapg 15 }
+
+ altHostLowestUpos OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Host Location - Lowest U-position"
+ ::= { immtrapg 16 }
+
+ altHostBladeBay OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Host Location - BladeBay"
+ ::= { immtrapg 17 }
+
+ altEventID OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Event Identifier"
+ ::= { immtrapg 18 }
+
+ altServiceable OBJECT-TYPE
+ SYNTAX INTEGER {
+ notServiceable(0),
+ serviceableByIBM(1),
+ serviceableByCustomer(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Serviceability information."
+ ::= { immtrapg 19 }
+
+ altTest OBJECT-TYPE
+ SYNTAX INTEGER {
+ false(0),
+ true(1)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This event generated for test purposes."
+ ::= { immtrapg 20 }
+
+ altFailingFRUs OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Ordered list of Failing FRU Numbers, separated by commas."
+ ::= { immtrapg 21 }
+
+ altHostMTM OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Machine Type and Model for failing host."
+ ::= { immtrapg 22 }
+
+ altAuxData OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Auxiliary data that may be included for some events."
+ ::= { immtrapg 23 }
+
+
+-- ******************************************
+-- Critical Traps
+-- ******************************************
+ ibmSpTrapTempC TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Critical Alert: Temperature threshold exceeded."
+ ::= 0
+
+ ibmSpTrapVoltC TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Critical Alert: Voltage threshold exceeded."
+ ::= 1
+
+ ibmSpTrapPowerC TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Critical Alert: Power failure."
+ ::= 4
+
+ ibmSpTrapHdC TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Critical Alert: Hard disk drive failure."
+ ::= 5
+
+ ibmSpTrapFanC TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Critical Alert: Single Fan failure."
+ ::= 11
+
+
+ ibmSpTrapIhcC TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Critical Alert: Incompatible hardware configuration."
+ ::= 36
+
+ ibmSpTrapCPUC TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Critical Alert: CPU Error."
+ ::= 40
+
+ ibmSpTrapMemoryC TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Critical Alert: Memory Error."
+ ::= 41
+
+ ibmSpTrapRdpsC TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Critical Alert: Redundant Power Supply failure."
+ ::= 9
+
+ ibmSpTrapHardwareC TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Critical Alert: Other Failure - refer to Message ID for specific condition."
+ ::= 50
+
+-- ******************************************
+-- Non-Critical Traps
+-- ******************************************
+
+ ibmSpTrapRdpsN TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Non-Critical Alert: Redundant Power Supply failure."
+ ::= 10
+
+ ibmSpTrapTempN TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Non-Critical Alert: Temperature threshold exceeded."
+ ::= 12
+
+ ibmSpTrapVoltN TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Non-Critical Alert: Voltage threshold exceeded."
+ ::= 13
+
+ ibmSpTrapPowerN TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Non-Critical Alert: Power."
+ ::= 164
+
+ ibmSpTrapFanN TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Non-Critical Alert: Fan Error."
+ ::= 165
+
+ ibmSpTrapCPUN TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Non-Critical Alert: CPU Error."
+ ::= 42
+
+ ibmSpTrapMemoryN TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Non-Critical Alert: Memory Error."
+ ::= 43
+
+ ibmSpTrapHardwareN TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Non-Critical Alert: Warning - refer to Message ID for specific condition."
+ ::= 60
+
+-- ******************************************
+-- System Traps
+-- ******************************************
+
+ ibmSpTrapRLogin TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "Sev-Off Alert: Event Remote Login."
+ ::= 30
+
+
+ ibmSpTrapOsToS TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "System Alert: OS Timeout value exceeded."
+ ::= 21
+
+ ibmSpTrapAppS TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "System Alert: Application Alert. Refer to Message ID for specific condition."
+ ::= 22
+
+ ibmSpTrapPoffS TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "System Alert: Power Off."
+ ::= 23
+
+ ibmSpTrapPonS TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "System Alert: Power On."
+ ::= 24
+
+ ibmSpTrapBootS TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "System Alert: System Boot Failure."
+ ::= 25
+
+ ibmSpTrapLdrToS TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "System Alert: OS Loader Timeout."
+ ::= 26
+
+ ibmSpTrapPFAS TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "System Alert: Predictive Failure Analysis(PFA) information."
+ ::= 27
+
+ ibmSpTrapSysLogS TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "System Alert: System Log 75% full."
+ ::= 35
+
+ ibmSpTrapNwChangeS TRAP-TYPE
+ ENTERPRISE immalertMIB
+ VARIABLES
+ {
+ altDateTime,
+ altSpTxtId,
+ altSysUuid,
+ altSysSern,
+ altMsgID,
+ altMsgIDPrefix,
+ altPriority,
+ altMsgText,
+ altHostContact,
+ altHostLocation,
+ altHostRoomID,
+ altHostRackID,
+ altHostLowestUpos,
+ altHostBladeBay,
+ altEventID,
+ altServiceable,
+ altTest,
+ altFailingFRUs,
+ altHostMTM,
+ altAuxData
+ }
+ DESCRIPTION
+ "System Alert: Network change notification."
+ ::= 37
+END
+
+
+
+
+
+
+
+
+