diff options
Diffstat (limited to 'MIBS/infinera/LUM-EQUIPMENT-MIB')
| -rw-r--r-- | MIBS/infinera/LUM-EQUIPMENT-MIB | 5726 |
1 files changed, 5726 insertions, 0 deletions
diff --git a/MIBS/infinera/LUM-EQUIPMENT-MIB b/MIBS/infinera/LUM-EQUIPMENT-MIB new file mode 100644 index 0000000..6d1c632 --- /dev/null +++ b/MIBS/infinera/LUM-EQUIPMENT-MIB @@ -0,0 +1,5726 @@ +LUM-EQUIPMENT-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, NOTIFICATION-TYPE + FROM SNMPv2-SMI + OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP + FROM SNMPv2-CONF + DisplayString, DateAndTime, RowStatus, TestAndIncr, TEXTUAL-CONVENTION + FROM SNMPv2-TC + lumModules, lumEquipmentMIB + FROM LUM-REG + MgmtNameString, SubrackNumber, SlotNumber, + BoardOrInterfaceOperStatus, BoardOrInterfaceAdminStatus, ObjectProperty, + CommandString, FaultStatus, AdminStatus, TruthValueWithNA + FROM LUM-TC + AlarmPerceivedSeverity + FROM LUM-ALARM-MIB; + +lumEquipmentMIBModule MODULE-IDENTITY + LAST-UPDATED + "201908300000Z" -- August 30th 2019 + ORGANIZATION + "Infinera Corporation" + CONTACT-INFO + "techsupport@infinera.com" + DESCRIPTION + "The common equipment configuration MIB. + + - General + + - Subrack status + + - Board configuration and status + + - Power supply status + + - Fan status + + - Slot + +" + REVISION + "201908300000Z" -- August 30th 2019 + DESCRIPTION + "Changes made for release r33.1: + - Add CO2xOTDR filter + - Add CO-D4 filter series" + REVISION + "201906280000Z" -- June 28th 2019 + DESCRIPTION + "Changes made for release r33.0: + - Added oa1x21dBmVgEC board + - Added oa2x21dBmVgEC board + - added the emxp800xh board" + REVISION + "201903310000Z" -- March 31st 2019 + DESCRIPTION + "Changes made for release r32.1: + - added the emxp440q board + - modify power supply type" + REVISION + "201812210000Z" -- Dec 21th 2018 + DESCRIPTION + "Changes made for release r32.0: + - added tm3000iie subrack" + REVISION + "201807010000Z" -- July 01 2018 + DESCRIPTION + "Changes made for release r31.0: + - added the hdea1600 board + - added optical module table + - improved/corrected the help text for ICN redundancy mode + - added the otdr8p board" + REVISION + "201712150000Z" -- December 15 2017 + DESCRIPTION + "Changes made for release r30.0: + - added the emxp440 board + - added oaraed20lghyb board + - added roadm1x9f board + - added ad1c2fotdr board" + REVISION + "201706150000Z" -- June 15th 2017 + DESCRIPTION + "Changes made for release r29.0: + - Changed ORGANIZATION and CONTACT-INFO" + REVISION + "201702250000Z" -- February 25th 2017 + DESCRIPTION + "Changes made for release r28.1: + - Added emxp48 temp hardened board." + REVISION + "201611300000Z" -- November 30th 2016 + DESCRIPTION + "Changes made for release r28: + - Added tp100gotnii board. + - Added operationalVariant (normal or openFlowControlled). + - Added ptio100g board. + - Added AID and physical location for board." + REVISION + "201607150000Z" -- July 15th 2016 + DESCRIPTION + "Changes made for release r27: + - Added tmFha1UDc1 subrack + - Added fhau1 board + - Added fha1u1 board + - Added oa1x20dBmVg2 board + - Added oa2x20dBmVg2 board + - Added default operStatus to notPresent + - Added fwReloadNeeded and fwContextUnknown alarms + - Added settable severity for attribute DCPowerFailed + - Added nidSfp2488, PORT_DEVICE_SFP_2488 + - Added edu10GLT + - Added edu10GLTS" + REVISION + "201509300000Z" -- September 30th 2015 + DESCRIPTION + "Changes made for release r26: + - Added fpu1 board + - Added oaraed21hghyb board + - Added oaraed21hgind board + - Added dcDk652km100 board + - Added dcDk652km120 board + - Added dcP652km20 board" + REVISION + "201509150000Z" -- September 15th 2015 + DESCRIPTION + "Changes made for release r25.1: + - Added tpmrHL16GUni board." + REVISION + "201501130000Z" -- January 13th 2015 + DESCRIPTION + "Changes made for release r25: + - Added emxp240iie board" + REVISION + "201409300000Z" -- September 30th 2014 + DESCRIPTION + "Changes made for release r23.1: + - Added mxp100gotn board. + - Added additionalInfo for TPQMS." + REVISION + "201405160000Z" -- May 16th 2014 + DESCRIPTION + "Changes made for release r23: + - Added emxp220iie board. + - Added tpmrHL16G board. + - Changed board name from tp10gotn to tphex10gotn. + - Added fhmxp10g board" + REVISION + "201311150000Z" -- November 15th 2013 + DESCRIPTION + "Changes made for release r22: + - Added tp10gotn board. + - Added tp100gotn board." + REVISION + "201305010000Z" -- May 1st 2013 + DESCRIPTION + "Changes made for release r21: + - Added postpone firmware upgrade for + msMxp10G, gbeMxp10GFEC, msMxp and tpD10GbE. + - Added tpq10gfeci board. + - Added tpq10gfecregi board. + - Attributes for postpone of firmware + activation added. + - Feature not supported alarm added for msMxp + and gbeMxp10GFEC + - Feature Proxy ARP added" + REVISION + "201212200000Z" -- Dec 20th 2012 + DESCRIPTION + "Changes made for release r20: + - Added msTp40G board. + - Added msMxp40G board. + - Added mxp10gotn board. + - Added ocudq board. + - Added ocuseed2p board. + - Added oa2x21seed board. + - Added tm100mxp board. + - Added tm100tp board. + - Added tm100reg board. + - Added oa2x21seed board. + - Added support for boot error alarm. + - Added hardware error alarm. + - Added fan fault alarm. + - Added low disk space alarm. + - Added clock drift alarm. + - Added tm2000 subrack. + - Added tm3000ii subrack. + - Added Slot table." + REVISION + "201112200000Z" -- December 20th 2011 + DESCRIPTION + "Changes made for release r18: + - Added MDU16 board type. + - Added dcnRedundancy. + - Created LUM-SITE-MIB and moved External Alarms table to it + - Regenerator board added." + REVISION + "201106211100Z" -- June 21st 2011 + DESCRIPTION + "Added two TM2000 boards." + REVISION + "201104271100Z" -- April 27th 2011 + DESCRIPTION + "Added more TM boards." + REVISION + "200701311100Z" -- January 31th 2007 + DESCRIPTION + "Added TS-1100 board types." + REVISION + "200601270000Z" -- January 27th 2006 + DESCRIPTION + "Added TS-1100 specific alarms." + REVISION + "200509260000Z" -- September 26th 2005 + DESCRIPTION + "Added TS-1100 mux/demux board types." + REVISION + "200509140000Z" -- September 14th 2005 + DESCRIPTION + "Added minimal compliance groups." + REVISION + "200302170000Z" -- February 17th 2003 + DESCRIPTION + "Added new board types; obu, sync2Mhz, mxp8 and mxp16" + REVISION + "200211200000Z" -- November 20th 2002 + DESCRIPTION + "Changed name of the CU OSC boards." + REVISION + "200209160000Z" -- September 16th 2002 + DESCRIPTION + "Added internal communication mode." + REVISION + "200205310000Z" -- May 31st 2002 + DESCRIPTION + "Added equipmentNodeLedTest." + REVISION + "200203050000Z" -- March 5th 2002 + DESCRIPTION + "Re-defined operStatus. + Added boardUnderMaintenance alarm." + REVISION + "200202210000Z" -- February 21st 2002 + DESCRIPTION + "Added exextedType, actualType and unexpectedType for subracks." + REVISION + "200202200000Z" -- February 20th 2002 + DESCRIPTION + "Allows creation of subrack entries." + REVISION + "200112030000Z" -- December 3rd 2001 + DESCRIPTION + "Moved admin and operStatus definitions to LUM-TC" + REVISION + "200111220000Z" -- November 22nd 2001 + DESCRIPTION + "Changed definitions of the board traps." + REVISION + "200111090000Z" -- November 9th 2001 + DESCRIPTION + "Changed severity and alias for unexpectedType. + Added notifications for board table changes." + REVISION + "200110300000Z" -- October 30th 2001 + DESCRIPTION + "Added multiplexer and io-unit board types. + TestAndIncr and MIB version are hidden - not supported yet. + Removed autoSignal from board adminStatus." + REVISION + "200110250000Z" -- October 25th 2001 + DESCRIPTION + "Added subrack number for subracks. + Changed alias for powerEntry" + REVISION + "200110230000Z" -- October 23d 2001 + DESCRIPTION + "Moved lambdaDirection, lambdaDirection and lambdaFrequency to LUM-TC." + REVISION + "200110100000Z" -- October 10th 2001 + DESCRIPTION + "Moved most of the old LAMBDA-mib to this MIB. + Updated alarm names according to the event definitions. + Shortened the board type names. + Defined adminStatus and operStatus. + Updated max-access to indicate attributes for row-creation. + Added 'hidden' property." + REVISION + "200108140000Z" -- August 14th 2001 + DESCRIPTION + "Changes after first review. + Defined the first two board types. + Added list of future board types. + Added actual board type. + Fixed sub-rack, slot and port nubmering. + Clarified definition of 'wavelength'. + Removed some superfluous default values. + Descriptions for all alarms. + Board index is no longer persistent. + Added compliance groups. + Changed name of lambdaWaveLength to lambdaFrequency. + Shortened the name of one alarm. + Added lastChangeTime attributes." + REVISION + "200108090000Z" -- August 9th 2001 + DESCRIPTION + "Added LED test. Fixed some comments. + Defined adminStatus and operStatus." + REVISION + "200108080000Z" -- August 8th 2001 + DESCRIPTION + "The initial revision of this module." + ::= { lumModules 12 } + + +-- ---------------------------------------------------- +-- Conformance area, containing groups and complicance +-- specifications. +-- ---------------------------------------------------- + +lumEquipmentConfs OBJECT IDENTIFIER ::= { lumEquipmentMIB 1 } +lumEquipmentGroups OBJECT IDENTIFIER ::= { lumEquipmentConfs 1 } +lumEquipmentCompl OBJECT IDENTIFIER ::= { lumEquipmentConfs 2 } +lumEquipmentMinimalGroups OBJECT IDENTIFIER ::= { lumEquipmentConfs 3 } +lumEquipmentMinimalCompl OBJECT IDENTIFIER ::= { lumEquipmentConfs 4 } + + +-- ---------------------------------------------------- +-- Root for objects in the equipment MIB +-- ---------------------------------------------------- + +lumEquipmentMIBObjects OBJECT IDENTIFIER ::= { lumEquipmentMIB 2 } + + +-- ---------------------------------------------------- +-- This MIB contains the following groups: +-- ---------------------------------------------------- + +equipmentGeneral OBJECT IDENTIFIER ::= { lumEquipmentMIBObjects 1 } +equipmentSubrackList OBJECT IDENTIFIER ::= { lumEquipmentMIBObjects 2 } +equipmentBoardList OBJECT IDENTIFIER ::= { lumEquipmentMIBObjects 3 } +equipmentPowerList OBJECT IDENTIFIER ::= { lumEquipmentMIBObjects 4 } +equipmentFanList OBJECT IDENTIFIER ::= { lumEquipmentMIBObjects 5 } +lumentisEquipmentNotifications OBJECT IDENTIFIER ::= { lumEquipmentMIBObjects 6 } +equipmentNode OBJECT IDENTIFIER ::= { lumEquipmentMIBObjects 7 } +equipmentResource OBJECT IDENTIFIER ::= { lumEquipmentMIBObjects 8 } +equipmentSlot OBJECT IDENTIFIER ::= { lumEquipmentMIBObjects 9 } +equipmentOpticalModuleList OBJECT IDENTIFIER ::= {lumEquipmentMIBObjects 10 } + +-- ---------------------------------------------------- +-- Textual Conventions +-- ---------------------------------------------------- + +EquipmentSubrackType ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The type of subrack: + + tm300 - The small subrack (old). + + tm3000 - The big subrack. + + tm3000ii - The big subrack, enhanced version. + + tm3000iie - The big subrack, enhanced second version. + + tm301 - The small subrack (new). + + tm301ii - A subrack for maximum four traffic boards, enhanced version. + tm101 - Pizza box subrack. + + tm101p - Passive pizza box subrack. + + tm102 - An even smaller pizza box. + + mba1 - Monolith for mobile access + + mba2 - Monolith for mobile access + + mba2E - Monolith for mobile access temp hardened + + tm102pas - Passive pizza box subrack with one full- + sized slot and one half-sized slot. + + tm102pas3 - Passive pizza box subrack with three + half-sized slots. + + tm101p - Passive pizza box subrack. + + tm2000 - Small subrack for 100 Gbps boards. + + aux - virtual subrack for external equipment. + + tmFha1UDc1 - Monolith for mobile front haul. + + tmRfuAc1 - Remote mobile front haul unit. + + tmEmxp1UDc - Emxp temp hardened unit. + + tmHdea1600Dc - Hdea1600 subrack. + + tmEmxpXh800G/DC - Emxp 800 XHAUL subrack." + + SYNTAX INTEGER { + undefined (0), + tm300 (1), + tm3000 (2), + tm301 (3), + tm101 (4), + tm101p (5), + aux (6), + tm102 (7), + mba1 (8), + mba2 (9), + mba2E (10), + tm102pas (11), + tm102pas3 (12), + tm3000ii (13), + tm2000 (14), + tm301ii (15), + tmFha1UDc1 (16), + tmRfuAc1 (17), + tmEmxp1UDc (18), + tmHdea1600Dc (19), + tm3000iie (20), + tmEmxpXh800Dc (21), + ts1100Subrack2Slots (9002), + tm206Subrack6Slots (9006), + ts1100Subrack8Slots (9011), + ts1100Subrack12Slots (9013) } + +EquipmentBoardType ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The functional type of the board. + At least one type is defined for each combination of + the following properties of the board: + + 1 - number of interfaces + + 2 - type of interfaces + + 3 - the functionality of the board (can usually be inferred from + the types of interfaces) + + The application should be able to determine which and how many + interfaces should be instantiated from the type. + + Functional types defined so far: + + Note: The following type is not in use. + + cu - Control unit + + tpMr2500 - Multi-rate 2500 Mb/s transponder + + ocu2 - Dual optical coupler unit (2x1:2) + + oxc8 - Optical cross-connect 8x8 ports + + oxc16 - Optical cross-connect 16x16 ports + + mxp028 - Muxponder 2xSTM-4 + 8xSTM-1 + + ad1AB, ad1BA - Single add-drop units, A/B- and B/A-type + + ad2AB, ad2BA - Double add-drop units, A/B- and B/A-type + + ad4AB, ad4BA - Quad add-drop units, A/B- and B/A-type + + tpDGbE - Dual GbE transponder + + oa - Optical amplifier unit + + oa2 - Dual Optical amplifier unit + + mdu8Ext - Optical mux/demux unit, extension, 8 ports + + mdu8Term - Optical mux/demux unit, terminal, 8 ports + + ocu4 - Quad optical coupler unit (4x1:2) + + Note: The following type is not in use. + + mxp004 - Muxponder 4xSTM-1 + + ad2oaAB - 2 channel add-drop unit, type A/B for use with + optical amplifier + + ad2oaBA - 2 channel add-drop unit, type B/A for use with + optical amplifier + + adcwdm - Single add-drop units for OSC channels. + + Note: The following type is not in use. + + ad1spr - 1 channel spur unit + + tp10G - 10 Gb/s transponder + + tpLMr2500 - 'Lite' version of the Multi-rate 2500 Mb/s transponder + + cu1osc - CU with one OSC i/f + + cu2osc - CU with two OSC i/fs + + obu - Optical band unit + + sync2Mhz - 2 MHz synchronization unit + + mxp8 - 8 tributaries (STM-1 or STM-4) muxponder + + mxp16 - 16 tributaries (STM-1 or STM-4) muxponder + + tpDGbED - Dual GbE transponder for DWDM + + tpDGbEC - Dual GbE transponder for CWDM + + tpDFcD - Dual fiber channel transponder for DWDM + + tpDFcC - Dual fiber channel transponder for CWDM + + tpFcGbED - Fiber channel and GbE transponder for DWDM + + tpFcGbEC - Fiber channel and GbE transponder for CWDM + + tpTFcD - Triple fiber channel transponder for DWDM + + tpQMr - Quad multirate transponder + + mdu4TermAB - Optical mux/demux unit, terminal, type A/B, 4 ports + + mdu4TermBA - Optical mux/demux unit, terminal, type B/A, 4 ports + + adc1wdm - Single add-drop units for CWDM channels. + + adc2wdm - Double add-drop units for CWDM channels. + + tp10GLAN - 10 Gb/s LAN DWDM transponder + + tp10GRC - 10 Gb/s Rate Concerving DWDM transponder + + escon8 - 8 channel ESCON muxponder + + tpMr25v2 - Multi-rate 2500 Mb/s transponder version 2 + + tpD10GbE - Double 10GbE Transponder, Basic Unit + + tpD10GbER - Double 10GbE Transponder, repeater + + mdu4ExtAB - Optical mux/demux unit, extension, type A/B, 4 ports + + mdu4ExtBA - Optical mux/demux unit, extension, type B/A, 4 ports + + oiuc50100 - Optical interleaver unit 50/100 GHz + + mROADM1P800 - Reconfigurable optical add/drop multiplexer + + mxp4x2G5 - 4xSTM-16/10Gb MuxPonder + + tp10GOtnTc - 10Gb/s C-band Tunable OTN Transponder + + mdu40Even - 40 channel Mux/Demux unit, even 50GHz DWDM + + mdu40Odd - 40 channel Mux/Demux unit, odd 50GHz DWDM + + mdu8Ee - 8 channel 50GHz Mux/Demux, extension port, even, 100GHz spacing + + mdu8Eo - 8 channel 50GHz Mux/Demux, extension port, odd, 100GHz spacing + + ocm2p - 2-port Optical Channel Monitor + + msMxp - MultiService MuxPonder + + voa8chii - 8ch Variable Optical Attenuator - II + + msMxpR - MultiService MuxPonder, repeater + + msMxpDQgbe - Double Quad MuxPonder + + gbe10Emxp10G - 10xGbE/10GbE Ethernet MuxPonder + + gbeMxp10GFEC - 10xGbE/10Gb MuxPonder, FEC + + roadm1x4G100 - 4-port Reconfigurable optical add/drop multiplexer + + dQgbeMxpR - Double Quad GbE MuxPonder, repeater + + tpQMS - Quad MultiService transponder + + tpQMSR - Quad MultiService transponder, repeater + + gbe22Emxp10G - 22xGbE/10GbE Ethernet MuxPonder + + mxp4x2G5Oc - 4x2,5G/10Gb MuxPonder in SONET mode + + voa2ch - 2ch Variable Optical Attenuator + + msMxp10GTCEr - Multiservice Muxponder Tunable 10G ER + + msMxp10G - Multiservice Muxponder 10G + + msMxpQMS2G5 - 2.5Gb Quad MultiService transponder + + gbe22Emxp10Gii - 22xGbE/10GbE Ethernet MuxPonder Next Generation + + bsu1x5Even - 1x5 Band Splitter Unit, Even 50 GhZ Spacing + + bsu1x5Odd - 1x5 Band Splitter Unit, Odd 50 GhZ Spacing + + mba1 - MS Access Collector 8xE1/T1+2xEth SDH/SONET mode + + mba1Sonet - Deprecated + + mba2 - MS Access Collector 16xE1/T1+4xEth SDH/SONET mode + + mba2Sonet - Deprecated + + mxpmbh1Sdh - MS Access Hub 4xSTM-1+16xEth SDH mode + + mxpmbh1Sonet - MS Access Hub 4xOC-3+16xEth SONET mode + + roadm1x8G50 - 8-port Reconfigurable optical add/drop multiplexer + + emxp80Gii - 8x10GbE Ethernet MuxPonder-II + + msMxpQMS2G5 - 2.5Gb Quad MultiService Repeater + + mxp8iiSdh - 8p SDH 2,5G Muxponder v2 + + mxp8iiSonet - 8p Sonet 2,5G Muxponder v2 + + mba2E - MS Access Collector 16xE1/T1+4xEth SDH/SONET mode Temp hardend + + mba2ptpSdh - MS Access Collector 16xE1/T1+4xEth point to point SDH mode + + mba2ptpSonet - MS Access Collector 16xE1/T1+4xEth point to point SONET mode + + mba2EptpSdh - MS Access Collector 16xE1/T1+4xEth point to point SDH mode Temp hardend + + mba2EptpSonet - MS Access Collector 16xE1/T1+4xEth point to point SONET mode Temp hardend + + tpq10Gfec - Quad MultiService 10G FEC Transponder + + mstp40g - Multiservice Transponder 40G + + msmxp40G - Multiservice Muxponder 40G + + cuSfpii - CU-SFP/II: CU with 4 SFP OSC ports + + coD40ev - Dual fiber DWDM Mux/Demux filter, 40 even channels, 50GHz spacing. + coD40eve - Dual fiber DWDM Mux/Demux filter with 1310 port, 40 even channels, 50 GHz spacing + coD40od - Dual fiber DWDM Mux/Demux filter, 40 odd channels, 50GHz spacing. + coD40ode - Dual fiber DWDM Mux/Demux filter with 1310 port, 40 odd channels, 50 GHz spacing + + dcDk652km20 - Dispersion Compensation Module 20 km + dcDk652km40 - Dispersion Compensation Module 40 km + dcDk652km60 - Dispersion Compensation Module 60 km + dcDk652km80 - Dispersion Compensation Module 80 km + dcDk652km100 - Dispersion Compensation Module 100 km + dcDk652km120 - Dispersion Compensation Module 120 km + dcP652km20 - Dispersion Compensation Module 20 km + dcP652km40 - Dispersion Compensation Module 40 km + dcP652km60 - Dispersion Compensation Module 60 km + dcP652km80 - Dispersion Compensation Module 80 km + dcP652km100 - Dispersion Compensation Module 100 km + dcP652km120 - Dispersion Compensation Module 120 km + + emxp40Gii - 4x10GbE Ethernet MuxPonder-II + + tpqmp - Quad MultiProtocol Transponder + + tpq10GfecReg - Quad MultiService 10G FEC Regenerator + + mdu16cl50g - Colorless Mux/Demux Unit + + voa8chsfp - 8ch SFP-based VOA unit + + mxp10gotn - OTN Muxponder 10G + + ocudq - Optical Coupler Unit, Dual Quad (2x1:4) + + ocuseed2p - 2-Port Seed Light coupler Unit + + tm4700 - TM2000 Shelf Controller + + tm4011 - TM2000 40Gb/s Muxponder + + tm100mxp - TM2000 100Gb/s Muxponder + + tm100tp - TM2000 100Gb/s Transponder + + tm100reg - TM2000 100Gb/s Regenerator + + oypatchcord - Optical Y-patch cord + + tpq10gfeci - Quad 10G FEC Transponder 1-slot + + tpq10gfecregi - Quad MultiService 10G FEC Regenerator 1-slot + + tphex10gotn - Hex 10G OTN Transponder + + tp100gotn - 100G OTN Transponder + + emxp220iie - 1x100GbE Ethernet MuxPonder-IIe + + tpmrHL16G - Hex MultiRate 16G Lite Transponder + + fhmxp10g - Fronthaul Muxponder 10G + + mxp100gotn - 100G OTN Muxponder + + fpu1 - Fiber Protection Unit + + oaraed21hghyb - RAMAN/EDFA 21dBm HG hybrid board + + oaraed21hgind - RAMAN/EDFA 21dBm HG individual board + + emxp3 - 8xMPO Ethernet MuxPonder-III + + ptio10g - PT Fabric i/O Unit 10&t + + fhau1 - Fronthaul Access Unit FHAU/1 + + fha1u1 - Hardened Fronthaul Access Unit + + tpmrHL16GUni - Hex MultiRate 16G Lite Transponder - - Unidirectional + + oa1x20dBmVg2 - Variable Gain EDFA 20dBm v2 + + oa2x20dBmVg2 - Dual Variable Gain EDFA 20dBm v2 + + fxp400gotn - 400G OTN Flexponder + + compo24 - CO-MPO24 CO-MPO24 + + tp100gotnii - 100G OTN Transponder-II + + rfu1 - Remote Fronthaul Unit + + roadm1x4f - 4-port Flex Reconfigurable optical add/drop multiplexer + + ptio100g - PT Fabric I/O Unit 100&t + + oadm2ch - 2ch DWDM OADM + + emxp1u - Hardened EMXP Unit + + emxp1us - Hardened EMXP with SDN + + mxp200gotn - 200G OTN Muxponder + + emxp440 - 440GbE Ethernet MuxPonder-III + + emxp440q - 440GbE Q Ethernet MuxPonder-III + + oaraed20lghyb - RAMAN/EDFA 20dBm LG hybrid board + + roadm1x9f - 9-port Flex Reconfigurable optical add/drop multiplexer + + ocm8p - 8-port Optical Channel Monitor + + ad1c2fotdr - 1ch CWDM add/drop filter with 1610nm OTDR + + hdea1600 - High Density Ethernet Aggregator + + codsf24mpo10104 - Filter for HDEA1600 + + otdr8p - Optical Time Domain Reflectometer + + oa1x21dBmVgEC - Variable Gain Extended C-band EDFA 21dBm + + oa2x21dBmVgEC - Dual Variable Gain Extended C-band EDFA 21dBm + + emxp800xh - Ethernet Muxponder 800 XHAUL" + + + + SYNTAX INTEGER { + undefined (0), + cu (1), -- No longer used + tpMr2500 (2), + oxc8 (3), + oxc16 (4), + ocu2 (5), + mxp028 (6), + ad1AB (7), + ad1BA (8), + ad2AB (9), + ad2BA (10), + ad4AB (11), + ad4BA (12), + tpDGbE (13), + oa (14), + mdu8Ext (15), + mdu8Term (16), + ocu4 (17), + mxp004 (18), -- No longer used + ad2oaAB (19), + ad2oaBA (20), + oa2 (21), + adcwdm (22), + ad1spr (23), -- No longer used + tp10G (24), + tpLMr2500 (25), + cu1osc (26), -- No longer used + cu2osc (27), + obu (28), + sync2Mhz (29), + mxp8 (30), + mxp16 (31), + tpDGbED (32), -- No longer used (5.0 060120 EvoId 327) + tpDGbEC (33), -- No longer used (4.0 Evo ID 206) + tpDFcD (34), + tpDFcC (35), + tpFcGbED (36), -- No longer used (5.0 060120 EvoId 327) + tpFcGbEC (37), -- No longer used (5.0 060120 EvoId 327) + tpTFcD (38), -- No longer used (5.0 060120 EvoId 327) + tpQMr (39), + mdu4TermAB (40), + mdu4TermBA (41), + ad1cwdm (42), + ad2cwdm (43), + tp10GLAN (44), + tp10GRC (45), -- No longer used (5.0 060120 EvoId 327) + escon8 (46), -- No longer used + oa1x15dBm (47), + oa2x15dBm (48), + gxp2500 (49), -- No longer used (5.0 060120 EvoId 327) + gxp2500Sfp (50), -- 10xAny xWDM - pluggable line i/f + gxp10G (51), -- No longer used + tpDGbEDv2 (52), -- No longer used (5.0 060120 EvoId 327) + tpDGbESfp (53), -- No longer used (5.0 060120 EvoId 327) + tpDFcDv2 (54), -- No longer used (5.0 060120 EvoId 327) + tpDFcSfp (55), -- No longer used (5.0 060120 EvoId 327) + ad2x1cwdm (56), -- 2 x 1 Ch CWDM + ad2x2cwdm (57), -- No longer used + mdu8Term2 (58), -- No longer used + tpDDGbE (59), -- Double Dual GbE + fpuOas2824 (60), -- External board: fiber protection unit + mu2F8C (61), -- MU-2F CWDM 8 ch + du2F8C (62), -- DU-2F CWDM 8 ch + tpD10GL (63), -- Double 10G Lite Transponder + tpDDGbER (64), -- Repeater + tp10GBu (65), -- No longer used + tp10GLANBu (66), -- No longer used + tp10GClBu (67), -- 10G (STM64) with client XFP + tp10GLANClBu (68), -- No longer used + mdu8EvenExt (69), -- 8 ch MDU for even channels, extension type + mdu8EvenTerm (70), -- 8 ch MDU for even channels, terminal type + oapre1x17dBm (71), -- No longer used (5.0 060120 EvoId 327) + oa2x17dBm (72), -- Dual OA 17 dBm Line-amp + oiuc100200 (73), -- Optical interleaver unit + oapow1x17dBm (74), -- No longer used (5.0 060120 EvoId 327) + oa1x17dBm (75), -- Single OA 17 dBm Line-amp + gbe9Mxp10G (76), -- 9xGbE/10Gb MuxPonder + ad1dwdm2F (77), -- 1ch/2 fiber DWDM add/drop + ad1cwdm2F (78), -- 1ch/2 fiber CWDM add/drop + mdu4Ext2F (79), -- 4ch CWDM Mux, 2 fiber, extendable + mdu4Term2F (80), -- 4ch CWDM Mux, 2 fiber, terminal + voa8ch (81), -- 8ch Voltage controlled attenuator unit + oa1x20dBm (82), -- Single OA 20 dBm amplifier df Gain 22 + oa2x20dBm (83), -- Dual OA 20 dBm amplifier df Gain 22 + fpuYm235 (84), -- External board: fiber protection unit + ad4dwdm2F (85), -- 4 ch/2 fiber DWDM add/drop + tpQMri (86), -- New QMR + oar450c (87), -- RAMAN + cuSfp (88), -- New CU architecture + tpMr25v2 (89), -- 2500 transponder version 2 + tpD10GbE (90), -- Double 10GbE, basic unit + tpD10GbER (91), -- Double 10GbE, repeater + mdu4ExtAB (92), -- Mux/demux 4 ports, extension, type A/B + mdu4ExtBA (93), -- Mux/demux 4 ports, extension, type B/A + oiuc50100 (94), -- Optical interleaver unit 50/100 GHz + mROADM1P800 (95), -- No longer used + edu6pGbE (96), -- No longer used + tp10GClTc (97), -- 10G tunable + mxp4x2G5 (98), -- 4xSTM-16/10Gb MuxPonder + oa1xLG20dBm (99), -- Single OA 20 dBm amplifier df Gain 26 + oa2xLG20dBm (100), -- Dual OA 20 dBm amplifier df Gain 26 + oa1xFG10dBm (101), -- Single flat gain OA 10 dBm amplifier + oa2xFG10dBm (102), -- Dual flat gain OA 10 dBm amplifier + tp10GOtnTc (103), -- 10G tunable OTN transponder + mdu40Even (104), -- 40 channel MDU, even 50 GHz DWDM + mdu40Odd (105), -- 40 channel MDU, odd 50 GHz DWDM + mdu8Ee (106), -- 8 channel 50GHz MDU, even, 100 GHz spacing + mdu8Eo (107), -- 8 channel 50GHz MDU, odd, 100 GHz spacing + ocm2p (108), -- 2 port Optical Channel Monitor + msMxp (109), -- MultiService MuxPonder + voa8chii (110), -- 8ch Variable Optical Attenuator - II + msMxpR (111), -- MultiService MuxPonder Repeater + msMxpDQgbe (112), -- DoubleQuad MuxPonder + tp10GTcEr (113), -- 10Gb/s C-band Tunable Ext Reach Transp + gbe10Emxp10G (114), -- 10xGbE/10GbE Ethernet MuxPonder + edu12pGbE (115), -- 12 port EDU with GbE line i/f + gbeMxp10GFEC (116), -- 10xGbE/10G FEC MuxPonder + roadm1x4G100 (117), -- 4-port ROADM + dQgbeMxpR (118), -- No longer used + tpQMS (119), -- Quad MultiService Transponder + tpQMSR (120), -- Quad MultiService Transponder Repeater + gbe22Emxp10G (121), -- 22xGbE/10GbE Ethernet MuxPonder + oa1x26dBm(122), -- Power Extender + pcu2p (123), -- Protection Control Unit + mxp4x2G5Oc (124), -- 4x2,5G/10Gb-OC Muxponder + voa2ch (125), -- 2ch Variable Optical Attenuator + msMxp10GTCEr (126), -- MultiService MuxPonder 10G Tunable + msMxp10G (127), -- MultiService Muxponder 10G + msMxpQMS2G5 (128), -- 2.5G Quad MultiService Transponder + gbe22Emxp10Gii (129),-- 22xGbE/10GbE Ethernet MuxPonder Next Generation + bsu1x5Even (130), -- 1x5 Band Splitter Unit / EVEN 50GHz + bsu1x5Odd (131), -- 1x5 Band Splitter Unit / ODD 50GHz + gbe10Emxp10Gii (132),-- 10xGbE/10GbE Ethernet MuxPonder Next Generation + mba1 (133), -- No longer used + mba1SonetDeprecated (134), -- Deprecated + mba2 (135), -- MS Access Collector 16xE1/T1+4xEth SDH/SONET mode + mba2SonetDeprecated (136), -- Deprecated + mxpmbh1Sdh (137), -- MS Access Hub 4xSTM-1+16xEth SDH mode + mxpmbh1Sonet (138), -- MS Access Hub 4xOC-3+16xEth SONET mode + roadm1x8G50 (139), -- 8-port ROADM + ad4Even50 (140), -- 4 Channel DWDM Add/Drop, Even 50GHz + ad4Odd50 (141), -- 4 Channel DWDM Add/Drop, Odd 50GHz + emxp80Gii (142), -- 8x10GbE Ethernet MuxPonder-II + msMxpQMS2G5R (143), -- 2.5G Quad MultiService Repeater + mxp8iiSdh (144), -- 8p SDH 2,5G Muxponder v2 + mxp8iiSonet (145), -- 8p Sonet 2,5G Muxponder v2 + mba2E (146), -- MS Access Collector 16xE1/T1+4xEth SDH/SONET mode Temp hardend + mba2ptpSdh (147), -- MS Access Collector 16xE1/T1+4xEth Point to point SDH mode + mba2ptpSonet (148), -- MS Access Collector 16xE1/T1+4xEth Point to point SONET mode + mba2EptpSdh (149), -- MS Access Collector 16xE1/T1+4xEth Point to point SDH mode Temp hardend + mba2EptpSonet (150), -- MS Access Collector 16xE1/T1+4xEth Point to point SONET mode Temp hardend + mdu40EvenL (151), -- 40ch MDU-Lite, even 50GHz DWDM + mdu40OddL (152), -- 40ch MDU-Lite, odd 50GHz DWDM + oa1x20dBmVg (153), -- Variable Gain Opt Ampl 20dBm C-band + oa2x20dBmVg (154), -- Dual Var Gain Opt Ampl 20dBm C-band + roadm1x2G100 (155), -- 1x2 ROADM 100GHz + roadm1x2G50 (156), -- 1x2 ROADM 50GHz + tpq10Gfec (157), -- Quad MultiService 10G FEC Transponder + cuSfpii (158), -- New CU architecture gen II + coD40ev (159), -- Dual fiber DWDM Mux/Demux filter, 40 even channels, 50GHz spacing. + coD40eve (160), -- Dual fiber DWDM Mux/Demux filter with 1310 port, 40 even channels, 50 GHz spacing + coD40od (161), -- Dual fiber DWDM Mux/Demux filter, 40 odd channels, 50GHz spacing. + coD40ode (162), -- No longer used + dcDk652km20 (163), -- Dispersion Compensation Module 20 km + dcDk652km40 (164), -- Dispersion Compensation Module 40 km + dcDk652km60 (165), -- Dispersion Compensation Module 60 km + dcDk652km80 (166), -- Dispersion Compensation Module 80 km + dcP652km40 (167), -- Dispersion Compensation Module 40 km + dcP652km60 (168), -- Dispersion Compensation Module 60 km + dcP652km80 (169), -- Dispersion Compensation Module 80 km + dcP652km100 (170), -- Dispersion Compensation Module 100 km + dcP652km120 (171), -- Dispersion Compensation Module 120 km + emxp40Gii (172), -- 4x10GbE Ethernet MuxPonder-II + tpqmp (173), -- Quad MultiProtocol Transponder + tpq10GfecReg (174), -- Quad MultiService 10G FEC Regenerator + mdu16cl50g (175), -- Colorless Mux/Demux Unit + voa8chsfp (176), -- 8ch SFP-based VOA unit + msTp40G (177), -- MultiService Transponder 40G + msMxp40G(178), -- MultiService MuxPonder 40G + mxp10gotn (179), -- OTN Muxponder 10G + emxp62iie (180), -- 22xGbE/4x10GbE Ethernet MuxPonder-IIe + emxp120iie (181), -- 12x10GbE Ethernet MuxPonder-IIe + ocudq (182), -- Optical Coupler Unit, Dual Quad (2x1:4) + tm4700 (183), -- TM2000 Shelf Controller + tm4011 (184), -- TM2000 40Gb/s Muxponder + tm100mxp (185), -- TM2000 100Gb/s Muxponder + tm100tp (186), -- TM2000 100Gb/s Transponder + tm100reg (187), -- No longer used + ocuseed2p (188), -- 2-Port Seed Light coupler Unit + oa2x21seed (189), -- Dual 21 dBm Seed Light Unit + oypatchcord (190), -- Optical Y-patch cord + tpq10gfeci (191), -- Quad MultiService 10G FEC Transponder 1-slot + tpq10gfecregi (192), -- Quad MultiService 10G FEC Regenerator 1-slot + tphex10gotn (193), -- Hex 10G OTN Transponder + emxp48iie (194), -- 8xGbE/4x10GbE Ethernet MuxPonder-IIe + tp100gotn (195), -- 100G OTN Transponder + emxp220iie (196), -- 1x100GbE Ethernet MuxPonder-IIe + tpmrHL16G (197), -- Hex MultiRate 16G Lite Transponder + fhmxp10g (198), -- Fronthaul Muxponder 10G + mxp100gotn (199), -- 100G OTN Muxponder + cuSfpiii (200), -- New CU architecture gen III, + emxp240iie (201), -- 24x10GbE Ethernet MuxPonder-IIe + tpmrHL16GUni (202), -- Hex MultiRate 16G Lite Transponder - Unidirectional + fpu1 (203), -- Fiber Protection Unit + oaraed21hghyb (204), -- Raman EDFA 21 HG hybrid board + oaraed21hgind (205), -- Raman EDFA 21 HG individual board + emxp3 (206), -- 8xMPO Ethernet MuxPonder-III + dcDk652km100 (207), -- Dispersion Compensation Module 100 km + dcDk652km120 (208), -- Dispersion Compensation Module 120 km + dcP652km20 (209), -- Dispersion Compensation Module 20 km + fhau1(210), -- Fronthaul Access Unit FHAU/1 + fha1u1(211), -- Hardened Fronthaul Access Unit + oa1x20dBmVg2 (212), -- Variable Gain EDFA 20dBm v2 + oa2x20dBmVg2 (213), -- Dual Variable Gain EDFA 20dBm v2 + ptio10g (214), -- PT-Fabric I/O Unit 10G + fxp400gotn (215), -- 400G OTN Flexponder + compo24 (216), -- CO_MPO24 cassette + rfu1 (217), -- Remote Fronthaul Unit + coD919926 (218), -- Dual fiber DWDM Mux/Demux filter, 8 channels, 100GHz spacing + coD927934 (219), -- Dual fiber DWDM Mux/Demux filter, 8 channels, 100GHz spacing + coD935942 (220), -- Dual fiber DWDM Mux/Demux filter, 8 channels, 100GHz spacing + coD943950 (221), -- Dual fiber DWDM Mux/Demux filter, 8 channels, 100GHz spacing + coD951958 (222), -- Dual fiber DWDM Mux/Demux filter, 8 channels, 100GHz spacing + coD919926e (223), -- Dual fiber DWDM Mux/Demux filter, 8 channels with ext port, 100GHz spacing + coD927934e (224), -- Dual fiber DWDM Mux/Demux filter, 8 channels with ext port, 100GHz spacing + coD935942e (225), -- Dual fiber DWDM Mux/Demux filter, 8 channels with ext port, 100GHz spacing + coD943950e (226), -- Dual fiber DWDM Mux/Demux filter, 8 channels with ext port, 100GHz spacing + coD951958e (227), -- Dual fiber DWDM Mux/Demux filter, 8 channels with ext port, 100GHz spacing + co4 (228), -- Dual fiber CWDM Mux/Demux filter, 8 channels + co5 (229), -- Dual fiber CWDM Mux/Demux filter, 8 channels + codsf20eva (230), -- Single fiber DWDM Mux/Demux filter, even channels, a-side + codsf20evb (231), -- Single fiber DWDM Mux/Demux filter, even channels, b-side + codsf4919 (232), -- Single fiber DWDM Mux/Demux filter + codsf4926 (233), -- Single fiber DWDM Mux/Demux filter + codsf4927 (234), -- Single fiber DWDM Mux/Demux filter + codsf4934 (235), -- Single fiber DWDM Mux/Demux filter + codsf4935 (236), -- Single fiber DWDM Mux/Demux filter + codsf4942 (237), -- Single fiber DWDM Mux/Demux filter + codsf4943 (238), -- Single fiber DWDM Mux/Demux filter + codsf4950 (239), -- Single fiber DWDM Mux/Demux filter + codsf4951 (240), -- Single fiber DWDM Mux/Demux filter + codsf4958 (241), -- Single fiber DWDM Mux/Demux filter + codsf2919 (242), -- Single fiber DWDM Mux/Demux filter + codsf2922 (243), -- Single fiber DWDM Mux/Demux filter + codsf2923 (244), -- Single fiber DWDM Mux/Demux filter + codsf2926 (245), -- Single fiber DWDM Mux/Demux filter + codsf2927 (246), -- Single fiber DWDM Mux/Demux filter + codsf2930 (247), -- Single fiber DWDM Mux/Demux filter + codsf2931 (248), -- Single fiber DWDM Mux/Demux filter + codsf2934 (249), -- Single fiber DWDM Mux/Demux filter + codsf2935 (250), -- Single fiber DWDM Mux/Demux filter + codsf2938 (251), -- Single fiber DWDM Mux/Demux filter + codsf2939 (252), -- Single fiber DWDM Mux/Demux filter + codsf2942 (253), -- Single fiber DWDM Mux/Demux filter + codsf2943 (254), -- Single fiber DWDM Mux/Demux filter + codsf2946 (255), -- Single fiber DWDM Mux/Demux filter + codsf2947 (256), -- Single fiber DWDM Mux/Demux filter + codsf2950 (257), -- Single fiber DWDM Mux/Demux filter + codsf2951 (258), -- Single fiber DWDM Mux/Demux filter + codsf2954 (259), -- Single fiber DWDM Mux/Demux filter + codsf2955 (260), -- Single fiber DWDM Mux/Demux filter + codsf2958 (261), -- Single fiber DWDM Mux/Demux filter + tp100gotnii (262), -- 100G OTN Transponder-II + roadm1x4f (263), -- 1x4 Flex ROADM + ptio100g (264), -- PT-Fabric I/O Unit 100G + oadm2ch (265), -- 2ch DWDM OADM + emxp1u(266), -- Hardened EMXP Unit + emxp1us(267), -- Hardened EMXP with SDN + mxp200gotn (268), -- 200G OTN Muxponder + emxp440 (269), -- 440G Ethernet MuxPonder + oaraed20lghyb (270),-- Raman EDFA 20 LG hybrid board + roadm1x9f (271), -- 1x9 Flex ROADM + ocm8p (272), -- 8 port Optical Channel Monitor + ad1c2fotdr (273), -- 1ch CWDM add/drop filter with 1610nm OTDR" + hdea1600 (274), -- High density ethernet aggregator + oa1xLG20dBmb (275), -- Single OA 20 dBm amplifier df Gain 26 (TU2 version) + oa2xLG20dBmb (276), -- Dual OA 20 dBm amplifier df Gain 26 (TU2 version) + oa1x20dBmVgb (277), -- Variable Gain Opt Ampl 20dBm C-band (TU2 version) + oa2x20dBmVgb (278), -- Dual Var Gain Opt Ampl 20dBm C-band (TU2 version) + codsf24mpo10104 (279), -- Single fiber DWDM Mux/Demux filter + otdr8p (280), -- 8 Port Optical Time Domain Reflectometer + coD48ev (281), -- 48ch MDU DWDM 50GHz Even (Not added in ENM R32.0 - marked as obsolete) + coD48od (282), -- 48ch MDU DWDM 50GHz Odd (Not added in ENM R32.0 - marked as obsolete) + emxp440q (283), -- 440G Q Ethernet MuxPonder + oa1x21dBmVgEC (284), -- Variable Gain Opt Ampl 21dBm Extended C-band + oa2x21dBmVgEC (285), -- Dual Variable Gain Opt Ampl 21dBm Extended C-band + co10 (286), -- Dual fiber CWDM Mux/Demux filter, 4 channels + emxp800xh (287), -- Ethernet Muxponder 800 XHAUL + coocuD4x4 (288), -- CO-OCUD4x4 contains two units of 4x4 couplers. + coocuD4x8 (289), -- CO-OCUD4x8 contains two units of 4x8 couplers. + cooiuc50100 (290), -- Optical interleaver unit 50/100 GHz + co2xOTDR1611 (291), -- Dual OTDR filter 1611nm + coD4919 (292), -- Dual fiber DWDM add/drop filter, 4 channels + coD4923 (293), -- Dual fiber DWDM add/drop filter, 4 channels + coD4927 (294), -- Dual fiber DWDM add/drop filter, 4 channels + coD4931 (295), -- Dual fiber DWDM add/drop filter, 4 channels + coD4935 (296), -- Dual fiber DWDM add/drop filter, 4 channels + coD4939 (297), -- Dual fiber DWDM add/drop filter, 4 channels + coD4943 (298), -- Dual fiber DWDM add/drop filter, 4 channels + coD4947 (299), -- Dual fiber DWDM add/drop filter, 4 channels + coD4951 (300), -- Dual fiber DWDM add/drop filter, 4 channels + coD4955 (301), -- Dual fiber DWDM add/drop filter, 4 channels + + -- TG Series of passive boards, modelled in TNM + tgCo4 (1001), -- CO-4 + tgCo5 (1005), -- CO-5 + tgCo6 (1006), -- CO-6 + tgCo7 (1007), -- CO-7 + tgCo8 (1008), -- CO-8 + tgCo9 (1009), -- CO-9 + tgCo10 (1010), -- CO-10 + tgCo11 (1011), -- CO-11 + tgCo12 (1012), -- CO-12 + tgCo14 (1014), -- CO-14 + tgCo15 (1015), -- CO-15 + tgCo16 (1016), -- CO-16 + tgCoDxxxyyy (1040), -- CO-DXXX-YYY + tgCoD40ev (1041), -- CO_D40EV + tgCoD40eve (1042), -- CO_D40EV-E + tgCoD40od (1043), -- CO_D40OD + tgCoD40ode (1044), -- CO_D40OD-E + tgCoBSU1x5ev (1050), -- CO-BSU1x5EV + tgCoBSU1x5od (1051), -- CO-BSU1x5OD + tgCad86XX04 (1055), -- OAD-86XX/04 + tgCad86XX02 (1056), -- OAD-86XX/02 + tgCoDSF2ch9XXAB (1057), -- CO-DSF2/9XX_AB + tgCoDSF4ch9XXAB (1058), -- CO-DSF4/9XX_AB + tgCoDSF2ch9XXBA (1059), -- CO-DSF2/9XX_BA + tgCoDSF4ch9XXBA (1060), -- CO-DSF4/9XX_BA + tgTcosf2x1b (1061), -- Passive CWDM AD TCO-SF 2x1 B + tgTcosf2x1d (1062), -- Passive CWDM AD TCO-SF 2x1 D TM-EDU Accedian + tgCoD4XXX (1070), -- CO-D4-XXX + tgCoDSF20 (1080), -- CO-DSF20 + tgCoDSF20evA (1081), -- CO-DSF20-EVA + tgCoDSF20evB (1082), -- CO-DSF20-EVB + tgCoDSF20odA (1083), -- CO-DSF20-ODA + tgCoDSF20odB (1084), -- CO-DSF20-ODB + tgCoSFBSU1x5ev (1085), -- CO-SFBBSU1x5EV + + tgTco12 (2012), -- TCO-12 + tgTco14 (2014), -- TCO-14 + + -- TM-EDU Accedian board types + acd2pGbE (10000), -- 2 port Accedian EDU + acd5pGbE (10001), -- 5 port Accedian EDU + acd10G (10002), -- Accedian EDU 10G + edu5GT (10003), -- EDU_ACD_5_GT + edu10GLT (10004), -- EDU_ACD_10G_LT + edu10GLTS (10005), -- EDU_ACD_10G_LTS + + -- Port device board types + nidGE (20000), -- PORT_DEVICE_NID_GE + nidSfp155 (20001), -- PORT_DEVICE_SFP_155 + nidSfp622 (20002), -- PORT_DEVICE_SFP_622 + nidSfpVc12 (20003), -- PORT_DEVICE_SFP_Vc12 + nidSfp2488 (20004), -- PORT_DEVICE_SFP_2488 + + -- TS-1100 board types + ts1100EthMux4p (220401), -- TS-1100 2204/01 Four port Ethernet Switch/Mux + ts1100OPU (250101), -- TS-1100 2501/01 Optical Protection Unit + ts1100OPUDouble (250201), -- TS-1100 2502/01 Optical Protection Unit (double width +1) + ts1100PreAmpDouble (260401), -- TS-1100 2604/01 Pre-Amplifier (double width +1) + ts1100PreAmp (261001), -- TS-1100 2610/01 Pre-Amplifier + ts1100AttenuatorDouble (270001), -- TS-1100 2700/01 Attenuator (double width -1) + -- fixme: TS-1100 270X/02 attenuator sub-modules + ts1100UnivAggDGbE (540001), -- TS-1100 5400/01 Universal aggregator + ts1100UnivAggDFC (540002), -- TS-1100 5400/02 Universal aggregator + ts1100UnivAggDGbE2 (540003), -- TS-1100 5400/03 Universal aggregator + ts1100UnivAgg (550000), -- TS-1100 5500/0x Universal aggregator + ts1100UnivAgg4xGbE (580000), -- TS-1100 5800/01 4xGbE Universal aggregator + ts1100UnivAgg2xDGbE (5800002), -- TS-1100 5800/01 Dual 2xGbE Universal aggregator + ts1100UnivAgg3xGbERep (5800003),-- TS-1100 5800/01 3xGbE Repeater Universal aggregator + ts1100UnivAgg3x25GRep (5800004),-- TS-1100 5800/01 3x2.5G Repeater Universal aggregator + ts1100UnivAgg2xGbE2xSTM (581000),-- TS-1100 5810/01 2xGbE 2xSTM Universal aggregator + ts1100UnivAgg4xGbE2 (5810002), -- TS-1100 5810/01 4xGbE Universal aggregator + ts1100UnivAgg3xGbERep2 (5810003),-- TS-1100 5810/01 3xGbE Repeater Universal aggregator + ts1100Muxponder10G (590000), -- TS-1100 5900/01 10G Muxponder 1x4,25Gb 4xGbE + ts1100Muxponder10G2 (5900002), -- TS-1100 5900/01 10G Muxponder 1G 2x4GFC + ts1100Nmb (600100), -- TS-1100 6001 Network management board + ts1100Nmb6003 (600300), -- TS-1100 6003 Network management board + ts1100Tp2x4GFC (740001), -- TS-1100 7400/01 2x4Gb-Transponders + ts1100Conv1250Cwdm (750000), -- TS-1100 702[0-3] 1,25 Gb CWDM Converter + -- TS-1100 75[01-18]/* 1,25 Gb CWDM Converter + -- TS-1100 75[01-18]/01 Repeater versions not supported + ts1100Conv2500Cwdm (760000), -- TS-1100 76[01-16]/* 2,5 Gb CWDM Converter + -- TS-1100 76[01-16]/01 Repeater versions not supported + -- TS-1100 76[01-16]/11 Repeater versions not supported + ts1100Tp2500Cwdm1 (770000), -- TS-1100 7700/0[1-2] 2,5 Gb CWDM Transponder + ts1100Tp2x2500Cwdm1 (772000), -- TS-1100 7720/01 2x 2,5 Gb CWDM Transponder + ts1100Tp10G (790000), -- TS-1100 7900/01 10 Gb Transponder + ts1100Tp10G7910 (791000), -- TS-1100 7910/01 10 Gb Transponder + ts1100Tp10G7910Rep (7910002), -- TS-1100 7910/01 10 Gb Repeater + ts1100DuplexerDouble (802001), -- TS-1100 8120/01 Wdm duplexer (double width) + ts1100MuxDemux4chPizza (803000), -- TS-1100 8030 4 ch mux/demux (pizza) + ts1100MuxDemux4chExtPizza (803100), -- TS-1100 8031 4 ch mux/demux with ext (pizza) + ts1100MuxDemux8chPizza (803200), -- TS-1100 8032 mux/demux (pizza) + -- TS-1100 8034 mux/demux (pizza) + ts1100MuxDemux8chExtPizza (803300), -- TS-1100 8033 mux/demux with ext/monitor (ext) + ts1100Duplexer (812001), -- TS-1100 8120/01 Wdm duplexer + ts1100MuxDemux4ch1t4 (813001), -- TS-1100 8130/01 4 channel (1-4) mux/demux + ts1100MuxDemux4p1ch1t4 (813101), -- TS-1100 8131/01 4+1 channel (1-4) mux/demux + ts1100MuxDemux8ch (813200), -- TS-1100 813[2-4] 8 channel mux/demux (piu) + ts1100MuxDemux8p1ch (813300), -- TS-1100 813[2-4] 8+1 channel mux/demux (piu) + ts1100MuxDemux8ch2 (813400), -- TS-1100 813[2-4] 8 channel mux/demux 2 (piu) + ts1100MuxDemux4ch5t8 (814001), -- TS-1100 8140/01 4 channel (5-8) mux/demux + ts1100MuxDemux4p1ch5t8 (814101), -- TS-1100 8141/01 4+1 channel (5-8) mux/demux + ts1100MuxDemux4chBidir (823000), -- TS-1100 8230/[0-1][1-2] 4 channel bidir CWDM mux/demux + ts1100AddDropDouble (850100), -- TS-1100 850[1-8]/* oadm (double width -1) + ts1100AddDrop (870101), -- TS-1100 870[1-8]/01 CWDM OADM + ts1100AddDropSingle (870102), -- TS-1100 870[1-8]/02 CWDM Single Sided OADM + ts1100DWDMMuxDemuxExt (883001), -- TS-1100 8830/01 DWDM mux/demux band A ext + ts1100DWDMMuxDemux (883101), -- TS-1100 8831/01 DWDM mux/demux band B + -- TS-1100 8832/01 DWDM mux/demux band C + ts1100Power9000Supply (900000), -- TS-1100 Unconfigured powersupply in 9011 subrack + ts1100Power9048Supply (904800), -- TS-1100 48 V DC Power supply in 9011 subrack + ts1100Power9122Supply (912200), -- TS-1100 220 V DC Power supply in 9013 subrack + ts1100Power9148Supply (914800), -- TS-1100 48 V DC Power supply in 9013 subrack + ts1100Power9220Supply (922000), -- TS-1100 220 V DC Power supply in 9011 subrack + + -- TM-206 board types + tm206Fan (9200201), -- TM-206 2002/01 Fan + tm206OSC1 (9221001), -- TM-206 2210/01 OSC board + tm206OSC2 (9221002), -- TM-206 2210/02 OSC board + tm206TAM4xesc (9500101), -- TM-206 5001/01 Traffic aggregator 4xescon + tm206TAMln4xesc (9510101), -- TM-206 5101/01 Traffic aggregator line+4xescon + tm206TAMln4xetr (9510201), -- TM-206 5102/01 Traffic aggregator line+4xetr + tm206TAMlnFlex (9510301), -- TM-206 5103/01 Traffic aggregator flexible + tm206TAMln2xfc (9510401), -- TM-206 5104/01 Traffic aggregator 2xfc,gbe + tm206TAMlnp2xfc (9510501), -- TM-206 5105/01 Traffic aggregator 2xfc,gbe + tm206Cu (9600201), -- TM-206 6002/01 Network management board + tm206Cu2 (9600202), -- TM-206 6002/02 Network management board + tm206tp2x4gfc (9780001), -- TM-206 7800/01 2x4Gb-Transponders + tm206MuxDemux4ch1t4 (9813001), -- TM-206 8130/01 4 channel (1-4) mux/demux + tm206MuxDemux4p1ch1t4 (9813101), -- TM-206 8131/01 4+1 channel (1-4) mux/demux + tm206MuxDemux4ch5t8 (9814001), -- TM-206 8140/01 4 channel (5-8) mux/demux + tm206MuxDemux4p1ch5t8 (9814101), -- TM-206 8141/01 4+1 channel (5-8) mux/demux + tm206MuxDemux4chBidir1 (9823001), -- TM-206 8230/01 4 channel bidir CWDM mux/demux + tm206MuxDemux4chBidir2 (9823002), -- TM-206 8230/02 4 channel bidir CWDM mux/demux + tm206AddDrop (9870101) -- TM-206 870[1-8]/01 CWDM OADM + } + +FirstPbSlot ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "A value indicating the first slot where it is + possible to configure a passive board in a subrack. + + undefined - indicates that no value has yet been set. + + slot3 - Slot 3 is the first passive slot. + + slot4 - Slot 4 is the first passive slot. + + slot13 - Slot 13 is the first passive slot." + SYNTAX INTEGER { + undefined(0), + slot3(3), + slot4(4), + slot13(13) } + +-- ---------------------------------------------------- +-- General group +-- ---------------------------------------------------- + +equipmentGeneralTestAndIncr OBJECT-TYPE + SYNTAX TestAndIncr + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Protection against simultaneous access from + multiple managers. See SNMPv2-TC. + +" + ::= { equipmentGeneral 1 } + +equipmentGeneralMibSpecVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The MIB specification version. + + tbd: persistent? + +" + DEFVAL { "" } + ::= { equipmentGeneral 2 } + +equipmentGeneralMibImplVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The MIB implementation version. + +" + DEFVAL { "" } + ::= { equipmentGeneral 3 } + +equipmentGeneralLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the configuration of the MIB was last + changed. + +" + ::= { equipmentGeneral 4 } + +equipmentGeneralStateLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the state of the MIB was last changed. + +" + ::= { equipmentGeneral 5 } + +equipmentGeneralEquipmentSubrackTableSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Size of table + +" + ::= { equipmentGeneral 6 } + +equipmentGeneralEquipmentBoardTableSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Size of table + +" + ::= { equipmentGeneral 7 } + +equipmentGeneralEquipmentPowerTableSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Size of table + +" + ::= { equipmentGeneral 8 } + +equipmentGeneralEquipmentFanTableSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Size of table + +" + ::= { equipmentGeneral 9 } + +equipmentGeneralEquipmentSlotTableSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Size of table + +" + ::= { equipmentGeneral 10 } + +equipmentGeneralEquipmentOpticalModuleTableSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Size of table + +" + ::= { equipmentGeneral 11 } + +-- ---------------------------------------------------- +-- Subrack information +-- ---------------------------------------------------- + +equipmentSubrackTable OBJECT-TYPE + SYNTAX SEQUENCE OF EquipmentSubrackEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The subrack list." + ::= { equipmentSubrackList 1 } + +equipmentSubrackEntry OBJECT-TYPE + SYNTAX EquipmentSubrackEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the subrack list. + +" + INDEX { equipmentSubrackIndex } + ::= { equipmentSubrackTable 1 } + +EquipmentSubrackEntry ::= + SEQUENCE { + equipmentSubrackIndex Unsigned32, + equipmentSubrackName MgmtNameString, + equipmentSubrackSubrack SubrackNumber, + equipmentSubrackDescr DisplayString, + equipmentSubrackInvPhysIndexOrZero Unsigned32, + equipmentSubrackAllFanUnitsFailed FaultStatus, + equipmentSubrackRowStatus RowStatus, + equipmentSubrackExpectedType EquipmentSubrackType, + equipmentSubrackActualType EquipmentSubrackType, + equipmentSubrackUnexpectedType FaultStatus, + equipmentSubrackTemp Integer32, + equipmentSubrackTempHighExceeded FaultStatus, + equipmentSubrackTempThreshold Integer32, + equipmentSubrackDataChanged FaultStatus, + equipmentSubrackSystemModeSet FaultStatus, + equipmentSubrackEffectiveSystemMode Unsigned32, + equipmentSubrackCurrentSystemMode Unsigned32, + equipmentSubrackAdminStatus INTEGER, + equipmentSubrackOperStatus INTEGER, + equipmentSubrackObjectProperty ObjectProperty, + equipmentSubrackShelfLength Unsigned32, + equipmentSubrackLANModuleMissing FaultStatus, + equipmentSubrackExpectedFirstPbSlot FirstPbSlot, + equipmentSubrackActualFirstPbSlot FirstPbSlot, + equipmentSubrackFirstPbSlotMismatch FaultStatus, + equipmentSubrackAid DisplayString, + equipmentSubrackPhysicalLocation DisplayString, + equipmentSubrackChangeExpectedType CommandString } + +equipmentSubrackIndex OBJECT-TYPE + SYNTAX Unsigned32 (1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary index assigned to each + subrack entry. + +" + ::= { equipmentSubrackEntry 1 } + +equipmentSubrackName OBJECT-TYPE + SYNTAX MgmtNameString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the subrack, for example 'sub1' + where the number indicates the subrack number. + +" + ::= { equipmentSubrackEntry 2 } + +equipmentSubrackSubrack OBJECT-TYPE + SYNTAX SubrackNumber + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The number of the subrack. + +" + ::= { equipmentSubrackEntry 3 } + +equipmentSubrackDescr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "User configurable label. + +" + DEFVAL { "" } + ::= { equipmentSubrackEntry 4 } + +equipmentSubrackInvPhysIndexOrZero OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The row in the invPhysTable for this subrack. + Set to 0 if not known. + +" + ::= { equipmentSubrackEntry 5 } + +equipmentSubrackAllFanUnitsFailed OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "All fan units in a subrack have failed. + + A(ctivation): fanUnitFailed active for all fans + within a subrack. + + D(e-activiation): fanUnitFailed cleared for one + fan unit. + +" + ::= { equipmentSubrackEntry 6 } + +equipmentSubrackRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "SNMP administrivia. + Manages creation and deletion of conceptual rows. + See also SNMPv2-TC. + +" + ::= { equipmentSubrackEntry 7 } + +equipmentSubrackExpectedType OBJECT-TYPE + SYNTAX EquipmentSubrackType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The expected subrack type. + +" + DEFVAL { undefined } + ::= { equipmentSubrackEntry 8 } + +equipmentSubrackActualType OBJECT-TYPE + SYNTAX EquipmentSubrackType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The actual subrack type. If an unexpected + subrack has been detected this variable can be + used to see what type of subrack has been + detected. + +" + ::= { equipmentSubrackEntry 9 } + +equipmentSubrackUnexpectedType OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A type of subrack not matching the expected + type is present. + + A: A subrack with type different from the + expected type is present (even if the subrack + is not activated). + + D: The type matches the expected or no + subrack is present. + +" + ::= { equipmentSubrackEntry 10 } + +equipmentSubrackTemp OBJECT-TYPE + SYNTAX Integer32 (-1000..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The temperature in the subrack in 0.1 degrees centigrade. + +" + ::= { equipmentSubrackEntry 11 } + +equipmentSubrackTempHighExceeded OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The threshold for environmental temperature + in the subrack is exceeded. + + A: The temperature exceeds the associated threshold. + + D: Temperature is 0.5 degrees centigrade below the + associated threshold. + +" + ::= {equipmentSubrackEntry 12 } + +equipmentSubrackTempThreshold OBJECT-TYPE + SYNTAX Integer32 (-100..800) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The threshold for temperature alarm in the + subrack in 0.1 degrees centigrade. + +" + DEFVAL { 550 } + ::= { equipmentSubrackEntry 13 } + +equipmentSubrackDataChanged OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The subrack data (dipswitches for subrackId and/or + system mode) has been changed. Changing this data might + affect the system behaviour after the next restart. + + A: The subrack data has been changed since startup + + D: The subrack data is changed back to the value read + at startup, or the system is restarted. + +" + ::= {equipmentSubrackEntry 14 } + +equipmentSubrackSystemModeSet OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value read from the system mode + dipswitches at startup of the CU was + diffrent from 0. + + This will affect the behaviour of the + system. + + If the lowest bit is set, the backup + is read from the TUs - useful at CU + replacement. + + A: The system mode is different from 0 + at startup. + + D: The system mode is 0 at startup. + +" + ::= {equipmentSubrackEntry 15 } + +equipmentSubrackEffectiveSystemMode OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of the system mode dipswitches + read at startup. This value determines the + system behaviour. + +" + ::= { equipmentSubrackEntry 16 } + +equipmentSubrackCurrentSystemMode OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current value of the system mode + dipswitches. Will be used at the next + restart. + +" + ::= { equipmentSubrackEntry 17 } + +equipmentSubrackAdminStatus OBJECT-TYPE + SYNTAX INTEGER { + down (1), + up (2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The administrative state of the subrack. + + down - This subrack should not be monitored. + Suppresses alarms. + + up - The subrack should be monitored. + +" + DEFVAL { up } + ::= { equipmentSubrackEntry 18 } + +equipmentSubrackOperStatus OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + down (2), + up (3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational state of the subrack. + + notPresent - The subrack is not available. + + down - The subrack remains in the 'down'-state + when adminStatus is set to 'down'. + + up - The subrack is active and monitored. + +" + DEFVAL { notPresent } + ::= { equipmentSubrackEntry 19 } + +equipmentSubrackObjectProperty OBJECT-TYPE + SYNTAX ObjectProperty + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Property mask. + +" + ::= { equipmentSubrackEntry 20 } + +equipmentSubrackShelfLength OBJECT-TYPE + SYNTAX Unsigned32 (0..32) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Length of the half-height slot divider shelf. To be + manually entered by the user. A value of 0 is + interpreted as 'not yet defined by user'. + +" + DEFVAL { 0 } + ::= { equipmentSubrackEntry 21 } + +equipmentSubrackLANModuleMissing OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The subrack LAN/DCN module is missing. + + A(ctivation): LAN/DCN module disconnected from subrack + for more than 2 seconds. + + D(e-activiation): LAN/DCN module connected to subrack + for more than 2 seconds. + +" + ::= { equipmentSubrackEntry 22 } + +equipmentSubrackExpectedFirstPbSlot OBJECT-TYPE + SYNTAX FirstPbSlot + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lowest slot number where it is possible to + configure a passive board. Automatically configured + to the actual value supported by hardware if the + hardware is present on subrack configuration. + + If no hardware is present at configuration time, + this value is set to 'undefined' until changed by + the user. The 'undefined' value allows passive board + configuration in the same slots as the highest + possible firstPbSlot setting of the subrack type. + +" + DEFVAL { 0 } + ::= { equipmentSubrackEntry 23 } + +equipmentSubrackActualFirstPbSlot OBJECT-TYPE + SYNTAX FirstPbSlot + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The actual lowest slot number where it is possible + to configure a passive board. + + When no subrack hardware is present, this value is + 'undefined'. + +" + DEFVAL { 0 } + ::= { equipmentSubrackEntry 24 } + +equipmentSubrackFirstPbSlotMismatch OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The expected first passive slot allows more passive + boards than the hardware supports. + + A(ctivation): A subrack and control unit combination + which supports fewer passive boards + than configured is present. + + D(e-activiation): A subrack and control unit + combination which supports the + current configuration is present. + +" + ::= { equipmentSubrackEntry 25 } + +equipmentSubrackAid OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The access identifier (AID) of the product. + The format is according to GR-833. + +" + ::= { equipmentSubrackEntry 26 } + +equipmentSubrackPhysicalLocation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Physical location of the product. + The format is according to GR-833. + +" + ::= { equipmentSubrackEntry 27 } + + +equipmentSubrackChangeExpectedType OBJECT-TYPE + SYNTAX CommandString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Command to change expected type, + used when upgrading subrack to a new version, + e.g TM3000 to TM3000/II + +" + ::= { equipmentSubrackEntry 28 } + + + +-- ---------------------------------------------------- +-- Board information +-- ---------------------------------------------------- + +equipmentBoardTable OBJECT-TYPE + SYNTAX SEQUENCE OF EquipmentBoardEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The board list." + ::= { equipmentBoardList 1 } + +equipmentBoardEntry OBJECT-TYPE + SYNTAX EquipmentBoardEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the board list. + One entry for each slot. + +" + INDEX { equipmentBoardIndex } + ::= { equipmentBoardTable 1 } + +EquipmentBoardEntry ::= + SEQUENCE { + equipmentBoardIndex Unsigned32, + equipmentBoardName MgmtNameString, + equipmentBoardExpectedType EquipmentBoardType, + equipmentBoardActualType EquipmentBoardType, + equipmentBoardDescr DisplayString, + equipmentBoardSubrack SubrackNumber, + equipmentBoardSlot SlotNumber, + equipmentBoardTemp Integer32, + equipmentBoardInvPhysIndexOrZero Unsigned32, + equipmentBoardLedTest INTEGER, + equipmentBoardAdminStatus BoardOrInterfaceAdminStatus, + equipmentBoardOperStatus BoardOrInterfaceOperStatus, + equipmentBoardLastChangeTime DateAndTime, + equipmentBoardRowStatus RowStatus, + equipmentBoardMissing FaultStatus, + equipmentBoardUnexpectedType FaultStatus, + equipmentBoardTempHighExceeded FaultStatus, + equipmentBoardCommunicationFailure FaultStatus, + equipmentBoardInterworkFailed FaultStatus, + equipmentBoardSecondaryPowerFailed FaultStatus, + equipmentBoardVitalDataMissing FaultStatus, + equipmentBoardNonVitalDataMissing FaultStatus, + equipmentBoardUnderMaintenance FaultStatus, + equipmentBoardTempThreshold Integer32, + equipmentBoardSwVersionMismatch FaultStatus, + equipmentBoardObjectProperty ObjectProperty, + equipmentBoardTempLow FaultStatus, + equipmentBoardTempVeryHigh FaultStatus, + equipmentBoardReconfigure CommandString, + equipmentBoardLedStatus INTEGER, + equipmentBoardModuleInfo DisplayString, + equipmentBoardNewSwActivatedButNotRestarted FaultStatus, + equipmentBoardLowTemperature FaultStatus, + equipmentBoardTempLowThreshold Integer32, + equipmentBoardAdditionalInfo DisplayString, + equipmentBoardBootError FaultStatus, + equipmentBoardHardwareError FaultStatus, + equipmentBoardLowDiskSpace FaultStatus, + equipmentBoardClockDrift FaultStatus, + equipmentBoardPostponeFwUpgrade INTEGER, + equipmentBoardActivatePendingFwCommand CommandString, + equipmentBoardFwActivationPending FaultStatus, + equipmentBoardFeatureNotSupported FaultStatus, + equipmentBoardFwReloadNeeded FaultStatus, + equipmentBoardFwContextUnknown FaultStatus, + equipmentBoardBoardVariant INTEGER, + equipmentBoardCabinetConnectivity INTEGER, + equipmentBoardCabinetConnectionFailure FaultStatus, + equipmentBoardOperationalVariant INTEGER, + equipmentBoardAid DisplayString, + equipmentBoardPhysicalLocation DisplayString + } + +equipmentBoardIndex OBJECT-TYPE + SYNTAX Unsigned32 (1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary index assigned to each + board entry. + +" + ::= { equipmentBoardEntry 1 } + +equipmentBoardName OBJECT-TYPE + SYNTAX MgmtNameString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the board, for example 'tpmr2500:1:2' + where the first number indicates in which sub-rack + the board is present and the second number + in which slot. + +" + ::= { equipmentBoardEntry 2 } + +equipmentBoardExpectedType OBJECT-TYPE + SYNTAX EquipmentBoardType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The expected board type. + +" + DEFVAL { undefined } + ::= { equipmentBoardEntry 3 } + +equipmentBoardActualType OBJECT-TYPE + SYNTAX EquipmentBoardType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The actual board type. If an unexpected board + has been detected this variable can be used to + see what type of board has been detected. + +" + ::= { equipmentBoardEntry 4 } + +equipmentBoardDescr OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "User configurable label. + +" + DEFVAL { "" } + ::= { equipmentBoardEntry 5 } + +equipmentBoardSubrack OBJECT-TYPE + SYNTAX SubrackNumber + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The number of the subrack where the board is + located. + +" + DEFVAL { 0 } + ::= { equipmentBoardEntry 6 } + +equipmentBoardSlot OBJECT-TYPE + SYNTAX SlotNumber + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The slot where the board is located. + +" + DEFVAL { 0 } + ::= { equipmentBoardEntry 7 } + +equipmentBoardTemp OBJECT-TYPE + SYNTAX Integer32 (-1000..1000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The temperature on the board in 0.1 degrees + centigrade. + +" + ::= { equipmentBoardEntry 8 } + +equipmentBoardInvPhysIndexOrZero OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The row in the invPhysTable for this board. + Set to 0 if not known. + +" + ::= { equipmentBoardEntry 9 } + +equipmentBoardLedTest OBJECT-TYPE + SYNTAX INTEGER { + off (1), + on (2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LED test for the board. + + off - Normal operation. + + on - Light all leds. + +" + DEFVAL { off } + ::= { equipmentBoardEntry 10 } + +equipmentBoardAdminStatus OBJECT-TYPE + SYNTAX BoardOrInterfaceAdminStatus + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The administrative state of the board. + + down - The board should be inactive. + Alarms are suppressed. + + service - The board is activated but alarms are + suppressed. Intended for use during service or + re-configuration. When service is concluded + adminStatus should be set to 'up' again. + + up - The board should be activated when + it becomes available. Alarms are not suppressed. + +" + DEFVAL { down } + ::= { equipmentBoardEntry 11 } + +equipmentBoardOperStatus OBJECT-TYPE + SYNTAX BoardOrInterfaceOperStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational state of the board. + + notPresent - The board is not available. + + down - The board remains in the 'down'-state + when adminStatus is set to 'down' or if there is + a fault preventing it from going to the + 'up'-state. + + up - The board is operational. The operational + state becomes 'up' when adminStatus is set to + 'up' unless there are faults detected. + +" + DEFVAL { notPresent } + ::= { equipmentBoardEntry 12 } + +equipmentBoardLastChangeTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the operational state of the + board entry was last changed. + +" + ::= { equipmentBoardEntry 13 } + +equipmentBoardRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "SNMP administrivia. + Manages creation and deletion of conceptual rows. + See also SNMPv2-TC. + +" + ::= { equipmentBoardEntry 14 } + +equipmentBoardMissing OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "There is no board present in a slot where the + expected board type is defined. Suppressed if + administrative status is down. + + A(ctivation): Card out of place (COP) indication + active for more than 2 seconds. + + D(e-activation): Card out of place (COP) indication + inactive for more than 2 seconds. + +" + ::= { equipmentBoardEntry 15 } + +equipmentBoardUnexpectedType OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A type of board not matching the expected type + is present and active in the same slot. + Since the default value for the type is + 'undefined' this alarm is raised when inserting + an unconfigured board. + + A: A board with type different from the expected + type is present in the slot (even if the board + is not activated). + + D: The type matches the expected or no board is + present. + +" + ::= { equipmentBoardEntry 16 } + +equipmentBoardTempHighExceeded OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The threshold for environmental temperature + on the board is exceeded. + + A: The temperature exceeds the associated + threshold. + + D: Temperature is 0.5 degrees centigrade + below the associated threshold. + +" + ::= {equipmentBoardEntry 17 } + +equipmentBoardCommunicationFailure OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Communication between the control unit and the + the board has failed completely. + + A: There is a board present but there has been + no communication established within 20 seconds. + + D: Communication is established. + +" + ::= {equipmentBoardEntry 18 } + +equipmentBoardInterworkFailed OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Communication between the control unit and the + board has failed due to incompatible software. + + A: The control unit and the board have + in-compatible software. + + D: The control unit and the board have compatible + software. + +" + ::= {equipmentBoardEntry 19 } + +equipmentBoardSecondaryPowerFailed OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Secondary DC power (1.8 or 2.5 V) failure. + + A: The secondary DC power on the board has + failed. + + D: The secondary DC power is present. + + Note: If primary power fails a + 'communicationFailure' alarm will most likely + be raised instead. + +" + ::= {equipmentBoardEntry 20 } + +equipmentBoardVitalDataMissing OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Product data vital for the safe operation + of the equipment is missing. + + A: Product data missing. + + D: Product data present. + +" + ::= {equipmentBoardEntry 21 } + +equipmentBoardNonVitalDataMissing OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Administrative product data is missing. + + A: Product data missing. + + D: Product data present. + +" + ::= {equipmentBoardEntry 22 } + +equipmentBoardUnderMaintenance OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The board is undergoing maintenance, adminStatus + is set to service. + + A: AdminStatus is set to service. + + D: AdminStatus is set to another value. + +" + ::= {equipmentBoardEntry 23 } + +equipmentBoardTempThreshold OBJECT-TYPE + SYNTAX Integer32 (0..800) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The threshold for temperature alarm on the + board in 0.1 degrees centigrade. + +" + DEFVAL { 700 } + ::= { equipmentBoardEntry 24 } + +equipmentBoardSwVersionMismatch OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The version of the board SW does not match + the SW version running och the main CU. + + For versions to match, the release number, + e.g. 'r2b', must be the same. The build + number is not required to be the same. + + Examples: + r2b-2 matches r2b-1, r2b-2, ..., r2b-<n> + r2b-<n> does NOT match r2a-<m> + + A: The board is started with as SW version + other than the main CU. + + D: The board, or main CU, is restarted with + matching SW versions. + +" + ::= {equipmentBoardEntry 25 } + +equipmentBoardObjectProperty OBJECT-TYPE + SYNTAX ObjectProperty + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Property mask. + +" + ::= {equipmentBoardEntry 26 } + +equipmentBoardTempLow OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The low threshold for environmental temperature + on the board is exceeded. + + A: The temperature exceeds the associated + low threshold. + + D: Temperature is 0.5 degrees centigrade + above the associated threshold. + +" + ::= {equipmentBoardEntry 27 } + +equipmentBoardTempVeryHigh OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The very high threshold for environmental + temperature on the board is exceeded. + + A: The temperature exceeds the associated + threshold. + + D: Temperature is 0.5 degrees centigrade + below the associated threshold. + +" + ::= {equipmentBoardEntry 28 } + +equipmentBoardReconfigure OBJECT-TYPE + SYNTAX CommandString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Applicable for cu, cu2osc, cuSfp, cuSfpii and voa8chii. + + Reconfigure cu or cu2osc board to cuSfp. + Reconfigure cu2osc or cuSfp board to cuSfpii. + Reconfigure older CU-board to cuSfpiii. + Reconfigure voa8chii to voa8chsfp. + Reconfigure tpq10Gfec to tpq10gfeci or vise versa + Reconfigure tpq10GfecReg to tpq10gfecregi or vise versa + + " + ::= {equipmentBoardEntry 29 } + +equipmentBoardLedStatus OBJECT-TYPE + SYNTAX INTEGER { + clear (1), + minor (2), + major (3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "LED status for the board. + This is primarily intended for debugging + +" + ::= { equipmentBoardEntry 30 } + +equipmentBoardModuleInfo OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Information (for example firmware and serial number) about the module. + +" + ::= { equipmentBoardEntry 31 } + +equipmentBoardNewSwActivatedButNotRestarted OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A new SW version on the board has been activated, + but the board has not been rebooted. This means that + after the next reboot, a new SW will be active. + + For the main CU, this also means that the backup + will be read from a new directory. + + A: A new SW has been activated but the board has + not been rebooted within 12 hours. + + D: The board is rebooted or the SW is reverted. + +" + ::= {equipmentBoardEntry 32 } + + +equipmentBoardLowTemperature OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The environmental temperature on the board + is below startuptemperature (+3 centigrade). + + A: The temperature is below +3 degrees centigrade. + + D: Temperature has increased to +5 degrees centigrade. + +" + ::= {equipmentBoardEntry 33 } + +equipmentBoardTempLowThreshold OBJECT-TYPE + SYNTAX Integer32 (-400..400) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The threshold for low temperature alarm on the + board in 0.1 degrees centigrade. + +" + DEFVAL { 30 } + ::= { equipmentBoardEntry 34 } + +equipmentBoardAdditionalInfo OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Additional information about the board, + e.g. FPGA revision. + +" + DEFVAL { "" } + ::= { equipmentBoardEntry 35 } + +equipmentBoardBootError OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The card fails to boot. + + A: The card fails to boot. + + D: The card boot successfully. + +" + ::= {equipmentBoardEntry 36 } + +equipmentBoardHardwareError OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " A hardware error occured. + + A: A hardware error occured. + + D: No hardware error. + +" + ::= {equipmentBoardEntry 37 } + +equipmentBoardLowDiskSpace OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Low disk space in the board. + + A: Not enough disk space. + + D: Disk space is enough. + +" + ::= {equipmentBoardEntry 38 } + +equipmentBoardClockDrift OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Clock frequency is out of range. + + A: Clock frequency out is out of range. + + D: Clock frequency is in range. + +" + ::= {equipmentBoardEntry 39 } + +equipmentBoardPostponeFwUpgrade OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Postpone activation of new traffic firmware when + the board software is upgraded next time. If no + firmware changes are available when upgrading this + option will not have any effect. + +" + DEFVAL { disabled } + ::= {equipmentBoardEntry 40 } + +equipmentBoardActivatePendingFwCommand OBJECT-TYPE + SYNTAX CommandString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Command to activate a pending firmware upgrade. + +" + ::= {equipmentBoardEntry 41 } + +equipmentBoardFwActivationPending OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Firmware activation has been postponed in a + previous software upgrade. + +" + ::= {equipmentBoardEntry 42 } + +equipmentBoardFeatureNotSupported OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A configuration request has failed since the chosen + feature is not supported by the active firmware. + +" + ::= { equipmentBoardEntry 43 } + +equipmentBoardFwReloadNeeded OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The traffic HW has been programmed by a version + of the system that does not offer a supported + upgrade path to the currently running version. + This typically happens after a downgrade + or rollback of the SW. The state of the + traffic HW is formally unknown and further + changes to the traffic configuration cannot + be guaranteed. A reset of the traffic unit is + recommended. This will cause a short traffic hit. + +" + ::= { equipmentBoardEntry 44 } + +equipmentBoardFwContextUnknown OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The running version of the SW cannot recover + the settings of the traffic HW/FW. The state + of the traffic HW is unknown. A reset of the + traffic unit is recommended. + This will cause a short traffic hit. + +" + ::= { equipmentBoardEntry 45 } + +equipmentBoardBoardVariant OBJECT-TYPE + SYNTAX INTEGER { + dualMuxponderProt (1), + hexTransponder (2), + tripleMuxponderProt (3), + quadTransponderProt (4), + notApplicable (2147483647) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Determines board configuration. + + dualMuxponderProt - 2x Muxponder with protection + hexTransponder - 6x Transponder + tripleMuxponderProt - 3x Muxponder with protection + quadTransponderProt - 4x Transponder with protection + + notApplicable - 2147483647 is used to indicate that the attribute + is not used on the board. + +" + DEFVAL { notApplicable } + ::= { equipmentBoardEntry 46 } + +equipmentBoardCabinetConnectivity OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Monitor Cabinet status if enabled. Alarm is raised if connection is lost. +" + DEFVAL { disabled } + ::= { equipmentBoardEntry 47 } + +equipmentBoardCabinetConnectionFailure OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Connection to the cabinet has failed. +" + ::= { equipmentBoardEntry 48 } + +equipmentBoardOperationalVariant OBJECT-TYPE + SYNTAX INTEGER { + normal (1), + openFlowControlled (2) } + + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Operational Variant mode of board, Normal or OpenFlow Controlled. +" + DEFVAL { normal } + ::= { equipmentBoardEntry 49 } + +equipmentBoardAid OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The access identifier (AID) of the product. + The format is according to GR-833. + +" + ::= { equipmentBoardEntry 50 } + +equipmentBoardPhysicalLocation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Physical location of the product. + The format is according to GR-833. + +" + ::= { equipmentBoardEntry 51 } + +-- ---------------------------------------------------- +-- Power supply table +-- ---------------------------------------------------- + +equipmentPowerTable OBJECT-TYPE + SYNTAX SEQUENCE OF EquipmentPowerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The list of power supplies." + ::= { equipmentPowerList 1 } + +equipmentPowerEntry OBJECT-TYPE + SYNTAX EquipmentPowerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the power supply list. + +" + INDEX { equipmentPowerIndex } + ::= { equipmentPowerTable 1 } + +EquipmentPowerEntry ::= + SEQUENCE { + equipmentPowerIndex Unsigned32, + equipmentPowerName DisplayString, + equipmentPowerSubrack SubrackNumber, + equipmentPowerSlot Unsigned32, + equipmentPowerType INTEGER, + equipmentPowerInvPhysIndexOrZero Unsigned32, + equipmentPowerAdminStatus INTEGER, + equipmentPowerOperStatus INTEGER, + equipmentPowerRowStatus RowStatus, + equipmentPowerPowerFailed FaultStatus, + equipmentPowerACPowerFailed FaultStatus, + equipmentPowerDCPowerFailed FaultStatus, + equipmentPowerTemperatureHigh FaultStatus, + equipmentPowerModuleMissing FaultStatus, + equipmentPowerObjectProperty ObjectProperty, + equipmentPowerDCPowerFailedSeverity AlarmPerceivedSeverity, + equipmentPowerAid DisplayString, + equipmentPowerPhysicalLocation DisplayString + } + +equipmentPowerIndex OBJECT-TYPE + SYNTAX Unsigned32 (1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary index assigned to each power module. + +" + ::= { equipmentPowerEntry 1 } + +equipmentPowerName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the power module. + For example 'pow:1:2'. + +" + ::= { equipmentPowerEntry 2 } + +equipmentPowerSubrack OBJECT-TYPE + SYNTAX SubrackNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the subrack in which the power + module is present. + +" + ::= { equipmentPowerEntry 3 } + +equipmentPowerSlot OBJECT-TYPE + SYNTAX Unsigned32 (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the slot in which the power + module is present. + +" + ::= { equipmentPowerEntry 4 } + +equipmentPowerType OBJECT-TYPE + SYNTAX INTEGER { + undefined (0), + ac (1), + dc (2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The the type of power module. + + ac - AC power supply (230V). + + dc - DC power supply (48V). + +" + DEFVAL { undefined } + ::= { equipmentPowerEntry 5 } + +equipmentPowerInvPhysIndexOrZero OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The row in the invPhysTable for this power + module. Set to 0 if not known. + +" + ::= { equipmentPowerEntry 9 } + +equipmentPowerAdminStatus OBJECT-TYPE + SYNTAX INTEGER { + down (1), + up (2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The administrative state of the power module. + + down - This power module is not monitored. + Suppresses alarms. + + up - The power module is monitored. + +" + DEFVAL { up } + ::= { equipmentPowerEntry 10 } + +equipmentPowerOperStatus OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + down (2), + up (3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational state of the power module. + + notPresent - The power module is not present. + + down - The module is not active or there are + faults preventing it from going to the + 'up'-state. + + up - The module is operational. + +" + DEFVAL { notPresent } + ::= { equipmentPowerEntry 11 } + +equipmentPowerRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Manages creation and deletion of conceptual rows. + See also SNMPv2-TC. + +" + ::= { equipmentPowerEntry 12 } + +equipmentPowerACPowerFailed OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "AC power supply failed (230 V). + + A(ctivation): Active HW indication. + + D(e-activation): Inactive HW indication. + +" + ::= { equipmentPowerEntry 13 } + +equipmentPowerDCPowerFailed OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS obsolete + DESCRIPTION + "DC power supply failed (48 V). + + A: Active HW indication. + + D: Inactive HW indication. + +" + ::= { equipmentPowerEntry 14 } + +equipmentPowerTemperatureHigh OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The built-in temperature monitoring of the power + module thinks it is too hot. + + A: Active HW indication. + + D: Inactive HW indication. + +" + ::= { equipmentPowerEntry 15 } + +equipmentPowerModuleMissing OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power module is not available. + + A: Active HW indication. + + D: Inactive HW indication. + +" + ::= { equipmentPowerEntry 16 } + +equipmentPowerObjectProperty OBJECT-TYPE + SYNTAX ObjectProperty + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Property mask. + +" + ::= { equipmentPowerEntry 17 } + +equipmentPowerDCPowerFailedSeverity OBJECT-TYPE + SYNTAX AlarmPerceivedSeverity + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The severity of DC Power failed alarm. + +" + DEFVAL { minor } + ::= { equipmentPowerEntry 18 } + +equipmentPowerAid OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The access identifier (AID) of the product. + The format is according to GR-833. + +" + ::= { equipmentPowerEntry 19 } + +equipmentPowerPhysicalLocation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Physical location of the product. + The format is according to GR-833. + +" + ::= { equipmentPowerEntry 20 } + +equipmentPowerPowerFailed OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Power supply failed. + + A: Active HW indication. + + D: Inactive HW indication. + +" + ::= { equipmentPowerEntry 21 } + +-- ---------------------------------------------------- +-- Fan module table +-- ---------------------------------------------------- + +equipmentFanTable OBJECT-TYPE + SYNTAX SEQUENCE OF EquipmentFanEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The list of fan modules." + ::= { equipmentFanList 1 } + +equipmentFanEntry OBJECT-TYPE + SYNTAX EquipmentFanEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the fan module list. + +" + INDEX { equipmentFanIndex } + ::= { equipmentFanTable 1 } + +EquipmentFanEntry ::= + SEQUENCE { + equipmentFanIndex Unsigned32, + equipmentFanName DisplayString, + equipmentFanSubrack SubrackNumber, + equipmentFanSlot Unsigned32, + equipmentFanInvPhysIndexOrZero Unsigned32, + equipmentFanAdminStatus INTEGER, + equipmentFanOperStatus INTEGER, + equipmentFanRowStatus RowStatus, + equipmentFanUnitFailed FaultStatus, + equipmentFanMainUnitFailed FaultStatus, + equipmentFanObjectProperty ObjectProperty, + equipmentFanFanFault FaultStatus, + equipmentFanAid DisplayString, + equipmentFanPhysicalLocation DisplayString} + +equipmentFanIndex OBJECT-TYPE + SYNTAX Unsigned32 (1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary index assigned to each fan module. + +" + ::= { equipmentFanEntry 1 } + +equipmentFanName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the fan module. + For example 'fan:1:2', where the first number + indicates the subrack and the second number the + fan slot. + +" + ::= { equipmentFanEntry 2 } + +equipmentFanSubrack OBJECT-TYPE + SYNTAX SubrackNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the subrack in which the fan + module is present. + +" + ::= { equipmentFanEntry 3 } + +equipmentFanSlot OBJECT-TYPE + SYNTAX Unsigned32 (1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the fan-slot in which the fan + module is present. + +" + ::= { equipmentFanEntry 4 } + +equipmentFanInvPhysIndexOrZero OBJECT-TYPE + SYNTAX Unsigned32 (0..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The row in the invPhysTable for this fan module. + Set to 0 if not known. + +" + ::= { equipmentFanEntry 5 } + +equipmentFanAdminStatus OBJECT-TYPE + SYNTAX INTEGER { + down (1), + up (2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The administrative state of the fan module. + + down - This fan module should not be monitored. + Suppresses alarms. Useful if a subrack has only + one fan for some reason. + + up - The fan module should be monitored. + +" + DEFVAL { up } + ::= { equipmentFanEntry 6 } + +equipmentFanOperStatus OBJECT-TYPE + SYNTAX INTEGER { + notPresent (1), + down (2), + up (3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The operational state of the fan module. + + Note: It is not possible to distinguish between + a missing fan and a failed fan. Therefore + 'notPresent' is currently not used. + + down - The fan module is not de-activated or not + present or there are faults preventing it from + going to the 'up'-state. + + up - The fan module is active and monitored. + +" + DEFVAL { notPresent } + ::= { equipmentFanEntry 7 } + +equipmentFanRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Manages creation and deletion of conceptual rows. + See also SNMPv2-TC. + +" + ::= { equipmentFanEntry 8 } + +equipmentFanUnitFailed OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The fan module has failed or is absent. + + A(ctivation): Active HW indication. + + D(e-activation): Inactive HW indication. + +" + ::= { equipmentFanEntry 9 } + +equipmentFanMainUnitFailed OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The main fan module has failed or is absent. + + A(ctivation): Active HW indication. + + D(e-activation): Inactive HW indication. + +" + ::= { equipmentFanEntry 10 } + +equipmentFanObjectProperty OBJECT-TYPE + SYNTAX ObjectProperty + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Property mask. + +" + ::= { equipmentFanEntry 11 } + +equipmentFanFanFault OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Fan malfunction or fan speed differs from the set speed. + + A(ctivation): Active HW indication. + + D(e-activation): Inactive HW indication. + +" + ::= { equipmentFanEntry 12 } + +equipmentFanAid OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The access identifier (AID) of the product. + The format is according to GR-833. + +" + ::= { equipmentFanEntry 13 } + +equipmentFanPhysicalLocation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Physical location of the product. + The format is according to GR-833. + +" + ::= { equipmentFanEntry 14 } + +------------------------------------ +-- Optical Module Table +-- --------------------------------- +equipmentOpticalModuleTable OBJECT-TYPE + SYNTAX SEQUENCE OF EquipmentOpticalModuleEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The module list." + ::= { equipmentOpticalModuleList 1 } + +equipmentOpticalModuleEntry OBJECT-TYPE + SYNTAX EquipmentOpticalModuleEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the module list. + +" + INDEX { equipmentOpticalModuleIndex } + ::= { equipmentOpticalModuleTable 1 } + +EquipmentOpticalModuleEntry ::= + SEQUENCE { + equipmentOpticalModuleIndex Unsigned32, + equipmentOpticalModuleHostBoardType EquipmentBoardType, + equipmentOpticalModuleType MgmtNameString, + equipmentOpticalModuleName MgmtNameString, + equipmentOpticalModuleSubrack SubrackNumber, + equipmentOpticalModuleSlot SlotNumber, + equipmentOpticalModuleFirmwareVersion DisplayString, + equipmentOpticalModuleSerialNumber DisplayString, + equipmentOpticalModuleWarmingUpState TruthValueWithNA, + equipmentOpticalModuleFailure FaultStatus } + +equipmentOpticalModuleIndex OBJECT-TYPE + SYNTAX Unsigned32 (1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary index assigned to each entry. + +" + ::= { equipmentOpticalModuleEntry 1 } + +equipmentOpticalModuleHostBoardType OBJECT-TYPE + SYNTAX EquipmentBoardType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The actual board type hosting the optical module. + +" + ::= { equipmentOpticalModuleEntry 2 } + +equipmentOpticalModuleType OBJECT-TYPE + SYNTAX MgmtNameString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of optical module, + for example monitor, switch, wss, amp etc + +" + ::= { equipmentOpticalModuleEntry 3 } + +equipmentOpticalModuleName OBJECT-TYPE + SYNTAX MgmtNameString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The management name of the interface, + for example 'module:[HostBoardType]:[ moduleType]:[subrack]:[slot]'. + +" + ::= { equipmentOpticalModuleEntry 4 } + +equipmentOpticalModuleSubrack OBJECT-TYPE + SYNTAX SubrackNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the subrack where the module + is located. + +" + ::= { equipmentOpticalModuleEntry 5 } + +equipmentOpticalModuleSlot OBJECT-TYPE + SYNTAX SlotNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the slot where the module is + located. + +" + ::= { equipmentOpticalModuleEntry 6 } + +equipmentOpticalModuleFirmwareVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Firmware version of the module. + +" + ::= { equipmentOpticalModuleEntry 7 } + +equipmentOpticalModuleSerialNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Serial number of the module. + +" + ::= { equipmentOpticalModuleEntry 8 } + +equipmentOpticalModuleWarmingUpState OBJECT-TYPE + SYNTAX TruthValueWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + + "Module is warming up, the optics has not reached a stable + state. + + True: Module is warming up. + + False: Module is ready and optics have reached stable state. + +" + ::= { equipmentOpticalModuleEntry 9 } + +equipmentOpticalModuleFailure OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The module is experiencing a failure. + + A(ctivation): The module has failed + + D(e-activation): The module is OK again + +" + ::= { equipmentOpticalModuleEntry 10 } + + +-- ---------------------------------------------------- +-- Notifications +-- ---------------------------------------------------- + +equipmentNotifyPrefix OBJECT IDENTIFIER ::= { lumentisEquipmentNotifications 0 } + +equipmentBoardRowStatusActive NOTIFICATION-TYPE + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardLastChangeTime } + STATUS current + DESCRIPTION + "Sent when a board is added to the configuration. + +" + ::= { equipmentNotifyPrefix 1 } + +equipmentBoardRowStatusDestroy NOTIFICATION-TYPE + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardLastChangeTime } + STATUS deprecated + DESCRIPTION + "Sent when a board is removed from the + configuration. + +" + ::= { equipmentNotifyPrefix 2 } + +equipmentBoardRowStatusInserted NOTIFICATION-TYPE + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardLastChangeTime } + STATUS current + DESCRIPTION + "Sent when a board is physically inserted. + +" + ::= { equipmentNotifyPrefix 3 } + +equipmentBoardRowStatusRemoved NOTIFICATION-TYPE + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardLastChangeTime } + STATUS current + DESCRIPTION + "Sent when a board is physically removed. + +" + ::= { equipmentNotifyPrefix 4 } + +equipmentBoardRowStatusDeleted NOTIFICATION-TYPE + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardLastChangeTime } + STATUS current + DESCRIPTION + "Sent when a board is deleted from the + configuration. + +" + ::= { equipmentNotifyPrefix 5 } + +-- ---------------------------------------------------- +-- Node group +-- ---------------------------------------------------- + +equipmentNodeLedTest OBJECT-TYPE + SYNTAX INTEGER { + off (1), + on (2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "LED test for the network element. + + off - Normal operation. + + on - Light all leds. + +" + DEFVAL { off } + ::= { equipmentNode 1 } + +equipmentNodeIcnRedundancyMode OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + ring (3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Indicates whether the internal communication + network between sub-racks, ICN3 and ICN4, can be + connected in a redundant manner or not. + + disabled - Non-redundant ICN connection. + Both ICN ports are enable for forwarding. + Note: Connecting both ICN ports to the same internal switch + will cause a loop. + + ring - Redundant ICN connection. Only one ICN port at a time + is enabled for forwarding even if both are physically connected + and both links are up. + Note: The port that is first connected will be used for + forwarding and if disconnected, the other port will be + enabled automatically. + + disabled - Non-redundant connection. + + ring - Redundantly connected in a ring. + +" + DEFVAL { ring } + ::= { equipmentNode 2 } + +equipmentNodeMemoryProfile OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates whether memory profilation shall be + done or not. + + disabled - No memory profile + + enabled - Memory profile done + +" + DEFVAL { disabled } + ::= { equipmentNode 3 } + +equipmentAllowDummyPassiveSlots OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This option is applicable for TM-3000 + subracks only. + + Normally passive boards can only be created in + slots 13-22. Enabling this options allows the + user to create full-size passive board objects + in slot 2-12 as well. + + Note, however, that supervision of board presence + and reading of board inventory is NOT possible + in slot 2-12. + + Also note that half-size boards, like ad1AB, are + not allowed in slots 2-12. + + disabled - Passive boards NOT allowed in slots 2-12. + + enabled - Allow full-size passive boards objects + in slot 2-12. + +" + DEFVAL { disabled } + ::= { equipmentNode 4 } + +equipmentNodeManagementVlan OBJECT-TYPE + SYNTAX INTEGER { + off (1), + bridge2dcn (2), + on (3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Indicates if VLAN is available (via DCN for nodes with cu) or not. + + off - No bridging of VLAN. (mgmtVlan off in node) + + bridge2dcn - VLAN is bridged to DCN. (mgmtVlan on in node, used for cu) + + on - mgmtVlan is on, used for culess + +" + DEFVAL { off } + ::= { equipmentNode 5 } + +equipmentNodeMgmtVlanPrivacy OBJECT-TYPE + SYNTAX INTEGER { + isolated (1), + community (2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Set Mgmt Vlan privacy. Setting is for main subrack in node. + Boards affected (in R14.0) is gbeMxp10GFEC, msMxp10G, gbe10Emxp10G + and gbe22Emxp10G. + + isolated - privacy enabled. Not possible to communicate + between boards nor ports. In slave subrack setting is only + on ports, not boards + + community - privacy disabled. It is possible to communicate + between both boards and ports. + +" + DEFVAL { community } + ::= { equipmentNode 6 } + +equipmentNodeDcnRedundancyMode OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Indicates whether the DCN ports on a CU, DCN1 and DCN2, + can be connected in a redundant manner or not. + + disabled - Non-redundant DCN connection. + Both DCN ports are enable for forwarding. + Note: Connecting both DCN ports to the same ethernet switch + will cause a loop. + + enabled - Redundant DCN connection. Only one DCN port at a time + is enabled for forwarding even if both are physically connected + and both links are up. + Note: The port that is first connected will be used for + forwarding and if disconnected, the other port will be + enabled automatically. + + disabled - Non-redundant connection. + + enabled - Redundantly connected through a hub. + +" + DEFVAL { enabled } + ::= { equipmentNode 7 } + +equipmentNodeProxyArp OBJECT-TYPE + SYNTAX INTEGER { + disabled (1), + enabled (2) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Indicates if the Proxy ARP functionality is used. Using Proxy ARP simplifies + the IP-address allocation and minimizes the use of different subnets in the network. + + disabled - Proxy ARP function disabled. The nodes must be in different subnets and + PPP links use routing between the nodes. + + enabled - Proxy ARP function enabled. All nodes can be in the same IP-subnet and + PPP links do not require routing between the nodes. + The Gateway node/Gateway Network Element (GNE) act as router. + +" + DEFVAL { disabled } + ::= { equipmentNode 8 } + +-- ---------------------------------------------------- +-- Resource group +-- ---------------------------------------------------- + +equipmentResourceNumberOfBoards OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of boards, active and passive, currently in use + in this system +" + ::= { equipmentResource 1 } + +equipmentResourceMaxNumberOfBoards OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum number of boards, active and passive, that is + supported by the embedded software of this system +" + ::= { equipmentResource 2 } + +equipmentResourceNumberOfActiveBoards OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of active boards running on this system +" + ::= { equipmentResource 3 } + +equipmentResourceMaxNumberOfActiveBoards OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum number of active boards that is supported by the + embedded software of this system. +" + ::= { equipmentResource 4 } + +-- ---------------------------------------------------- +-- Slot table +-- ---------------------------------------------------- + +equipmentSlotTable OBJECT-TYPE + SYNTAX SEQUENCE OF EquipmentSlotEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The slot list." + ::= { equipmentSlot 1 } + +equipmentSlotEntry OBJECT-TYPE + SYNTAX EquipmentSlotEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the slot list. + One entry for each slot. + +" + INDEX { equipmentSlotIndex } + ::= { equipmentSlotTable 1 } + +EquipmentSlotEntry ::= + SEQUENCE { + equipmentSlotIndex Unsigned32, + equipmentSlotName MgmtNameString, + equipmentSlotSubrack SubrackNumber, + equipmentSlotSlot SlotNumber, + equipmentSlotAdminStatus AdminStatus, + equipmentSlotUsageState INTEGER, + equipmentSlotEmptySlot FaultStatus, + equipmentSlotEquipped TruthValueWithNA, + equipmentSlotAid DisplayString, + equipmentSlotPhysicalLocation DisplayString} + +equipmentSlotIndex OBJECT-TYPE + SYNTAX Unsigned32 (1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An arbitrary index assigned to each + slot entry. + +" + ::= { equipmentSlotEntry 1 } + +equipmentSlotName OBJECT-TYPE + SYNTAX MgmtNameString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the slot, for example 'tpmr2500:1:2' + where the first number indicates in which sub-rack + the slot is present and the second number + in which slot. + +" + ::= { equipmentSlotEntry 2 } + +equipmentSlotSubrack OBJECT-TYPE + SYNTAX SubrackNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of the subrack in which the slot + is present. + +" + ::= { equipmentSlotEntry 3 } + +equipmentSlotSlot OBJECT-TYPE + SYNTAX SlotNumber + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The slot number. + +" + ::= { equipmentSlotEntry 4 } + +equipmentSlotAdminStatus OBJECT-TYPE + SYNTAX AdminStatus + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The administrative state of the slot. + + down - The slot is not monitored. + + up - The interface should be activated. + +" + ::= { equipmentSlotEntry 5 } + +equipmentSlotUsageState OBJECT-TYPE + SYNTAX INTEGER { + notUsed (1), + used (2) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + " Tells if the slot is used or not. + + used - Slot is used. + + notUsed - Slot is not used. + +" + ::= { equipmentSlotEntry 6 } + +equipmentSlotEmptySlot OBJECT-TYPE + SYNTAX FaultStatus + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Slot is empty, alarm only applicable for systems with mendatory slot usage + + A: Slot is empty. + + D: No empty slot. + +" + ::= {equipmentSlotEntry 7 } + +equipmentSlotEquipped OBJECT-TYPE + SYNTAX TruthValueWithNA + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is the entity equipped. + +" + ::= { equipmentSlotEntry 8 } + +equipmentSlotAid OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The access identifier (AID) of the slot. + The format is according to GR-833. + +" + ::= { equipmentSlotEntry 9 } + +equipmentSlotPhysicalLocation OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The physical location of the slot. + The format is according to GR-833. + +" + ::= { equipmentSlotEntry 10 } + +-- ---------------------------------------------------- +-- Object and event groups +-- ---------------------------------------------------- + +equipmentGeneralGroup OBJECT-GROUP + OBJECTS { + equipmentGeneralTestAndIncr, + equipmentGeneralMibSpecVersion, + equipmentGeneralMibImplVersion, + equipmentGeneralLastChangeTime } + STATUS current + DESCRIPTION + "The general objects." + ::= { lumEquipmentGroups 1 } + +equipmentSubrackGroup OBJECT-GROUP + OBJECTS { + equipmentSubrackIndex, + equipmentSubrackName, + equipmentSubrackSubrack, + equipmentSubrackDescr, + equipmentSubrackInvPhysIndexOrZero, + equipmentSubrackAllFanUnitsFailed } + STATUS deprecated + DESCRIPTION + "The subrack module objects." + ::= { lumEquipmentGroups 2 } + +equipmentBoardGroup OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardTemp, + equipmentBoardLedTest, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardRowStatus, + equipmentBoardLastChangeTime, + equipmentBoardMissing, + equipmentBoardUnexpectedType, + equipmentBoardTempHighExceeded, + equipmentBoardCommunicationFailure, + equipmentBoardInterworkFailed, + equipmentBoardSecondaryPowerFailed, + equipmentBoardVitalDataMissing, + equipmentBoardNonVitalDataMissing } + STATUS deprecated + DESCRIPTION + "The board objects." + ::= { lumEquipmentGroups 3 } + +equipmentPowerGroup OBJECT-GROUP + OBJECTS { + equipmentPowerIndex, + equipmentPowerName, + equipmentPowerSubrack, + equipmentPowerSlot, + equipmentPowerType, + equipmentPowerInvPhysIndexOrZero, + equipmentPowerAdminStatus, + equipmentPowerOperStatus, + equipmentPowerRowStatus, + equipmentPowerACPowerFailed, + equipmentPowerDCPowerFailed, + equipmentPowerTemperatureHigh, + equipmentPowerModuleMissing } + STATUS deprecated + DESCRIPTION + "The power module objects." + ::= { lumEquipmentGroups 4 } + +equipmentFanGroup OBJECT-GROUP + OBJECTS { + equipmentFanIndex, + equipmentFanName, + equipmentFanSubrack, + equipmentFanSlot, + equipmentFanInvPhysIndexOrZero, + equipmentFanAdminStatus, + equipmentFanOperStatus, + equipmentFanRowStatus, + equipmentFanUnitFailed } + STATUS deprecated + DESCRIPTION + "The fan module objects." + ::= { lumEquipmentGroups 5 } + +equipmentGeneralGroupV2 OBJECT-GROUP + OBJECTS { + equipmentGeneralLastChangeTime } + STATUS deprecated + DESCRIPTION + "The equipment general objects v2." + ::= { lumEquipmentGroups 6 } + +equipmentNotificationGroup NOTIFICATION-GROUP + NOTIFICATIONS { + equipmentBoardRowStatusActive, + equipmentBoardRowStatusDestroy } + STATUS deprecated + DESCRIPTION + "The equipment notifications." + ::= { lumEquipmentGroups 7 } + +equipmentSubrackGroupV2 OBJECT-GROUP + OBJECTS { + equipmentSubrackIndex, + equipmentSubrackName, + equipmentSubrackSubrack, + equipmentSubrackDescr, + equipmentSubrackInvPhysIndexOrZero, + equipmentSubrackAllFanUnitsFailed, + equipmentSubrackRowStatus } + STATUS deprecated + DESCRIPTION + "The subrack module objects V2." + ::= { lumEquipmentGroups 8 } + +equipmentSubrackGroupV3 OBJECT-GROUP + OBJECTS { + equipmentSubrackIndex, + equipmentSubrackName, + equipmentSubrackSubrack, + equipmentSubrackDescr, + equipmentSubrackInvPhysIndexOrZero, + equipmentSubrackAllFanUnitsFailed, + equipmentSubrackRowStatus, + equipmentSubrackActualType, + equipmentSubrackExpectedType, + equipmentSubrackUnexpectedType } + STATUS deprecated + DESCRIPTION + "The subrack module objects V3." + ::= { lumEquipmentGroups 9 } + +equipmentBoardGroupV2 OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardTemp, + equipmentBoardLedTest, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardRowStatus, + equipmentBoardLastChangeTime, + equipmentBoardMissing, + equipmentBoardUnexpectedType, + equipmentBoardTempHighExceeded, + equipmentBoardCommunicationFailure, + equipmentBoardInterworkFailed, + equipmentBoardSecondaryPowerFailed, + equipmentBoardVitalDataMissing, + equipmentBoardNonVitalDataMissing, + equipmentBoardUnderMaintenance, + equipmentBoardTempThreshold } + STATUS deprecated + DESCRIPTION + "The board objects V2." + ::= { lumEquipmentGroups 10 } + +equipmentNodeGroup OBJECT-GROUP + OBJECTS { + equipmentNodeLedTest } + STATUS deprecated + DESCRIPTION + "The node objects." + ::= { lumEquipmentGroups 11 } + +equipmentGeneralGroupV3 OBJECT-GROUP + OBJECTS { + equipmentGeneralLastChangeTime, + equipmentGeneralStateLastChangeTime } + STATUS deprecated + DESCRIPTION + "The equipment general objects v3." + ::= { lumEquipmentGroups 12 } + +equipmentNodeGroupV2 OBJECT-GROUP + OBJECTS { + equipmentNodeLedTest, + equipmentNodeIcnRedundancyMode } + STATUS deprecated + DESCRIPTION + "The node objects." + ::= { lumEquipmentGroups 13 } + +equipmentNodeGroupV3 OBJECT-GROUP + OBJECTS { + equipmentNodeLedTest, + equipmentNodeIcnRedundancyMode, + equipmentNodeMemoryProfile} + STATUS deprecated + DESCRIPTION + "The node objects." + ::= { lumEquipmentGroups 14 } + +equipmentSubrackGroupV4 OBJECT-GROUP + OBJECTS { + equipmentSubrackIndex, + equipmentSubrackName, + equipmentSubrackSubrack, + equipmentSubrackDescr, + equipmentSubrackInvPhysIndexOrZero, + equipmentSubrackAllFanUnitsFailed, + equipmentSubrackRowStatus, + equipmentSubrackActualType, + equipmentSubrackExpectedType, + equipmentSubrackUnexpectedType, + equipmentSubrackTemp, + equipmentSubrackTempHighExceeded, + equipmentSubrackTempThreshold, + equipmentSubrackDataChanged } + STATUS deprecated + DESCRIPTION + "The subrack module objects V4." + ::= { lumEquipmentGroups 15 } + + +equipmentBoardGroupV3 OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardTemp, + equipmentBoardLedTest, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardRowStatus, + equipmentBoardLastChangeTime, + equipmentBoardMissing, + equipmentBoardUnexpectedType, + equipmentBoardTempHighExceeded, + equipmentBoardCommunicationFailure, + equipmentBoardInterworkFailed, + equipmentBoardSecondaryPowerFailed, + equipmentBoardVitalDataMissing, + equipmentBoardNonVitalDataMissing, + equipmentBoardUnderMaintenance, + equipmentBoardTempThreshold, + equipmentBoardSwVersionMismatch } + STATUS deprecated + DESCRIPTION + "The board objects V3." + ::= { lumEquipmentGroups 16 } + +equipmentNotificationGroupV2 NOTIFICATION-GROUP + NOTIFICATIONS { + equipmentBoardRowStatusActive, + equipmentBoardRowStatusDestroy, + equipmentBoardRowStatusInserted, + equipmentBoardRowStatusRemoved } + STATUS deprecated + DESCRIPTION + "The equipment notifications." + ::= { lumEquipmentGroups 17 } + +equipmentSubrackGroupV5 OBJECT-GROUP + OBJECTS { + equipmentSubrackIndex, + equipmentSubrackName, + equipmentSubrackSubrack, + equipmentSubrackDescr, + equipmentSubrackInvPhysIndexOrZero, + equipmentSubrackAllFanUnitsFailed, + equipmentSubrackRowStatus, + equipmentSubrackActualType, + equipmentSubrackExpectedType, + equipmentSubrackUnexpectedType, + equipmentSubrackTemp, + equipmentSubrackTempHighExceeded, + equipmentSubrackTempThreshold, + equipmentSubrackDataChanged, + equipmentSubrackSystemModeSet, + equipmentSubrackEffectiveSystemMode, + equipmentSubrackCurrentSystemMode, + equipmentSubrackAdminStatus, + equipmentSubrackOperStatus } + STATUS deprecated + DESCRIPTION + "The subrack module objects V5. (2.2)" + ::= { lumEquipmentGroups 18 } + +equipmentFanGroupV2 OBJECT-GROUP + OBJECTS { + equipmentFanIndex, + equipmentFanName, + equipmentFanSubrack, + equipmentFanSlot, + equipmentFanInvPhysIndexOrZero, + equipmentFanAdminStatus, + equipmentFanOperStatus, + equipmentFanRowStatus, + equipmentFanUnitFailed, + equipmentFanMainUnitFailed } + STATUS deprecated + DESCRIPTION + "The fan module objects." + ::= { lumEquipmentGroups 19 } + +equipmentGeneralGroupV4 OBJECT-GROUP + OBJECTS { + equipmentGeneralLastChangeTime, + equipmentGeneralStateLastChangeTime, + equipmentGeneralEquipmentSubrackTableSize, + equipmentGeneralEquipmentBoardTableSize, + equipmentGeneralEquipmentPowerTableSize, + equipmentGeneralEquipmentFanTableSize } + STATUS deprecated + DESCRIPTION + "The equipment general objects v4 (3.1)." + ::= { lumEquipmentGroups 20 } + +equipmentSubrackGroupV6 OBJECT-GROUP + OBJECTS { + equipmentSubrackIndex, + equipmentSubrackName, + equipmentSubrackSubrack, + equipmentSubrackDescr, + equipmentSubrackInvPhysIndexOrZero, + equipmentSubrackAllFanUnitsFailed, + equipmentSubrackRowStatus, + equipmentSubrackActualType, + equipmentSubrackExpectedType, + equipmentSubrackUnexpectedType, + equipmentSubrackTemp, + equipmentSubrackTempHighExceeded, + equipmentSubrackTempThreshold, + equipmentSubrackDataChanged, + equipmentSubrackSystemModeSet, + equipmentSubrackEffectiveSystemMode, + equipmentSubrackCurrentSystemMode, + equipmentSubrackAdminStatus, + equipmentSubrackOperStatus, + equipmentSubrackObjectProperty } + STATUS deprecated + DESCRIPTION + "The subrack module objects V6. (4.0)" + ::= { lumEquipmentGroups 21 } + +equipmentBoardGroupV4 OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardTemp, + equipmentBoardLedTest, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardRowStatus, + equipmentBoardLastChangeTime, + equipmentBoardMissing, + equipmentBoardUnexpectedType, + equipmentBoardTempHighExceeded, + equipmentBoardCommunicationFailure, + equipmentBoardInterworkFailed, + equipmentBoardSecondaryPowerFailed, + equipmentBoardVitalDataMissing, + equipmentBoardNonVitalDataMissing, + equipmentBoardUnderMaintenance, + equipmentBoardTempThreshold, + equipmentBoardSwVersionMismatch, + equipmentBoardObjectProperty } + STATUS deprecated + DESCRIPTION + "The board objects V4. (4.0)" + ::= { lumEquipmentGroups 22 } + +equipmentPowerGroupV2 OBJECT-GROUP + OBJECTS { + equipmentPowerIndex, + equipmentPowerName, + equipmentPowerSubrack, + equipmentPowerSlot, + equipmentPowerType, + equipmentPowerInvPhysIndexOrZero, + equipmentPowerAdminStatus, + equipmentPowerOperStatus, + equipmentPowerRowStatus, + equipmentPowerACPowerFailed, + equipmentPowerDCPowerFailed, + equipmentPowerTemperatureHigh, + equipmentPowerModuleMissing, + equipmentPowerObjectProperty } + STATUS deprecated + DESCRIPTION + "The power module objects (4.0)." + ::= { lumEquipmentGroups 23 } + +equipmentFanGroupV3 OBJECT-GROUP + OBJECTS { + equipmentFanIndex, + equipmentFanName, + equipmentFanSubrack, + equipmentFanSlot, + equipmentFanInvPhysIndexOrZero, + equipmentFanAdminStatus, + equipmentFanOperStatus, + equipmentFanRowStatus, + equipmentFanUnitFailed, + equipmentFanMainUnitFailed, + equipmentFanObjectProperty } + STATUS deprecated + DESCRIPTION + "The fan module objects (4.0)." + ::= { lumEquipmentGroups 24 } + +equipmentNodeGroupV4 OBJECT-GROUP + OBJECTS { + equipmentNodeLedTest, + equipmentNodeIcnRedundancyMode, + equipmentNodeMemoryProfile, + equipmentAllowDummyPassiveSlots} + STATUS deprecated + DESCRIPTION + "The node objects V4 (7.0)" + ::= { lumEquipmentGroups 25 } + +equipmentBoardGroupV5 OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardTemp, + equipmentBoardLedTest, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardRowStatus, + equipmentBoardLastChangeTime, + equipmentBoardMissing, + equipmentBoardUnexpectedType, + equipmentBoardTempHighExceeded, + equipmentBoardCommunicationFailure, + equipmentBoardInterworkFailed, + equipmentBoardSecondaryPowerFailed, + equipmentBoardVitalDataMissing, + equipmentBoardNonVitalDataMissing, + equipmentBoardUnderMaintenance, + equipmentBoardTempThreshold, + equipmentBoardSwVersionMismatch, + equipmentBoardObjectProperty, + equipmentBoardReconfigure } + STATUS deprecated + DESCRIPTION + "The board objects V5. (7.0)" + ::= { lumEquipmentGroups 26 } + +equipmentBoardGroupV6 OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardTemp, + equipmentBoardLedTest, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardRowStatus, + equipmentBoardLastChangeTime, + equipmentBoardMissing, + equipmentBoardUnexpectedType, + equipmentBoardTempHighExceeded, + equipmentBoardCommunicationFailure, + equipmentBoardInterworkFailed, + equipmentBoardSecondaryPowerFailed, + equipmentBoardVitalDataMissing, + equipmentBoardNonVitalDataMissing, + equipmentBoardUnderMaintenance, + equipmentBoardTempThreshold, + equipmentBoardSwVersionMismatch, + equipmentBoardObjectProperty, + equipmentBoardReconfigure, + equipmentBoardLedStatus } + STATUS deprecated + DESCRIPTION + "The board objects V6. (8.0)" + ::= { lumEquipmentGroups 27 } + +equipmentBoardGroupV7 OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardTemp, + equipmentBoardLedTest, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardRowStatus, + equipmentBoardLastChangeTime, + equipmentBoardMissing, + equipmentBoardUnexpectedType, + equipmentBoardTempHighExceeded, + equipmentBoardCommunicationFailure, + equipmentBoardInterworkFailed, + equipmentBoardSecondaryPowerFailed, + equipmentBoardVitalDataMissing, + equipmentBoardNonVitalDataMissing, + equipmentBoardUnderMaintenance, + equipmentBoardTempThreshold, + equipmentBoardSwVersionMismatch, + equipmentBoardObjectProperty, + equipmentBoardReconfigure, + equipmentBoardLedStatus, + equipmentBoardModuleInfo, + equipmentBoardTempLow, + equipmentBoardTempVeryHigh } + STATUS deprecated + DESCRIPTION + "The board objects V7. (9.0)" + ::= { lumEquipmentGroups 28 } + +equipmentNodeGroupV8 OBJECT-GROUP + OBJECTS { + equipmentNodeLedTest, + equipmentNodeIcnRedundancyMode, + equipmentNodeMemoryProfile, + equipmentAllowDummyPassiveSlots, + equipmentNodeManagementVlan} + STATUS deprecated + DESCRIPTION + "The node objects V8 (11.0)" + ::= { lumEquipmentGroups 29 } + +equipmentBoardGroupV8 OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardTemp, + equipmentBoardLedTest, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardRowStatus, + equipmentBoardLastChangeTime, + equipmentBoardMissing, + equipmentBoardUnexpectedType, + equipmentBoardTempHighExceeded, + equipmentBoardCommunicationFailure, + equipmentBoardInterworkFailed, + equipmentBoardSecondaryPowerFailed, + equipmentBoardVitalDataMissing, + equipmentBoardNonVitalDataMissing, + equipmentBoardUnderMaintenance, + equipmentBoardTempThreshold, + equipmentBoardSwVersionMismatch, + equipmentBoardObjectProperty, + equipmentBoardReconfigure, + equipmentBoardLedStatus, + equipmentBoardModuleInfo, + equipmentBoardTempLow, + equipmentBoardTempVeryHigh, + equipmentBoardNewSwActivatedButNotRestarted } + STATUS deprecated + DESCRIPTION + "The board objects V8. (12.0)" + ::= { lumEquipmentGroups 30 } + +equipmentNodeGroupV9 OBJECT-GROUP + OBJECTS { + equipmentNodeLedTest, + equipmentNodeIcnRedundancyMode, + equipmentNodeMemoryProfile, + equipmentAllowDummyPassiveSlots, + equipmentNodeManagementVlan, + equipmentNodeMgmtVlanPrivacy} + STATUS deprecated + DESCRIPTION + "The node objects V9 (14.0)" + ::= { lumEquipmentGroups 31 } + +equipmentResourceGroup OBJECT-GROUP + OBJECTS { + equipmentResourceNumberOfBoards, + equipmentResourceMaxNumberOfBoards, + equipmentResourceNumberOfActiveBoards, + equipmentResourceMaxNumberOfActiveBoards} + STATUS current + DESCRIPTION + "The resouce objects V1 (16.0)" + ::= { lumEquipmentGroups 32 } + +equipmentSubrackGroupV7 OBJECT-GROUP + OBJECTS { + equipmentSubrackIndex, + equipmentSubrackName, + equipmentSubrackSubrack, + equipmentSubrackDescr, + equipmentSubrackInvPhysIndexOrZero, + equipmentSubrackAllFanUnitsFailed, + equipmentSubrackRowStatus, + equipmentSubrackActualType, + equipmentSubrackExpectedType, + equipmentSubrackUnexpectedType, + equipmentSubrackTemp, + equipmentSubrackTempHighExceeded, + equipmentSubrackTempThreshold, + equipmentSubrackDataChanged, + equipmentSubrackSystemModeSet, + equipmentSubrackEffectiveSystemMode, + equipmentSubrackCurrentSystemMode, + equipmentSubrackAdminStatus, + equipmentSubrackOperStatus, + equipmentSubrackObjectProperty, + equipmentSubrackShelfLength } + STATUS deprecated + DESCRIPTION + "The subrack module objects V7. (16.0)" + ::= { lumEquipmentGroups 33 } + +equipmentSubrackGroupV8 OBJECT-GROUP + OBJECTS { + equipmentSubrackIndex, + equipmentSubrackName, + equipmentSubrackSubrack, + equipmentSubrackDescr, + equipmentSubrackInvPhysIndexOrZero, + equipmentSubrackAllFanUnitsFailed, + equipmentSubrackRowStatus, + equipmentSubrackActualType, + equipmentSubrackExpectedType, + equipmentSubrackUnexpectedType, + equipmentSubrackTemp, + equipmentSubrackTempHighExceeded, + equipmentSubrackTempThreshold, + equipmentSubrackDataChanged, + equipmentSubrackSystemModeSet, + equipmentSubrackEffectiveSystemMode, + equipmentSubrackCurrentSystemMode, + equipmentSubrackAdminStatus, + equipmentSubrackOperStatus, + equipmentSubrackObjectProperty, + equipmentSubrackShelfLength, + equipmentSubrackLANModuleMissing, + equipmentSubrackExpectedFirstPbSlot, + equipmentSubrackActualFirstPbSlot, + equipmentSubrackFirstPbSlotMismatch } + STATUS deprecated + DESCRIPTION + "The subrack module objects V8. (17.0)" + ::= { lumEquipmentGroups 34 } + +equipmentBoardGroupV9 OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardTemp, + equipmentBoardLedTest, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardRowStatus, + equipmentBoardLastChangeTime, + equipmentBoardMissing, + equipmentBoardUnexpectedType, + equipmentBoardTempHighExceeded, + equipmentBoardCommunicationFailure, + equipmentBoardInterworkFailed, + equipmentBoardSecondaryPowerFailed, + equipmentBoardVitalDataMissing, + equipmentBoardNonVitalDataMissing, + equipmentBoardUnderMaintenance, + equipmentBoardTempThreshold, + equipmentBoardSwVersionMismatch, + equipmentBoardObjectProperty, + equipmentBoardReconfigure, + equipmentBoardLedStatus, + equipmentBoardModuleInfo, + equipmentBoardTempLow, + equipmentBoardTempVeryHigh, + equipmentBoardNewSwActivatedButNotRestarted, + equipmentBoardLowTemperature, + equipmentBoardTempLowThreshold } + STATUS deprecated + DESCRIPTION + "The board objects V9. (17.0)" + ::= { lumEquipmentGroups 35 } + +equipmentNotificationGroupV3 NOTIFICATION-GROUP + NOTIFICATIONS { + equipmentBoardRowStatusActive, + equipmentBoardRowStatusInserted, + equipmentBoardRowStatusRemoved, + equipmentBoardRowStatusDeleted } + STATUS current + DESCRIPTION + "The equipment notifications." + ::= { lumEquipmentGroups 36 } + +equipmentBoardGroupV10 OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardTemp, + equipmentBoardLedTest, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardRowStatus, + equipmentBoardLastChangeTime, + equipmentBoardMissing, + equipmentBoardUnexpectedType, + equipmentBoardTempHighExceeded, + equipmentBoardCommunicationFailure, + equipmentBoardInterworkFailed, + equipmentBoardSecondaryPowerFailed, + equipmentBoardVitalDataMissing, + equipmentBoardNonVitalDataMissing, + equipmentBoardUnderMaintenance, + equipmentBoardTempThreshold, + equipmentBoardSwVersionMismatch, + equipmentBoardObjectProperty, + equipmentBoardReconfigure, + equipmentBoardLedStatus, + equipmentBoardModuleInfo, + equipmentBoardTempLow, + equipmentBoardTempVeryHigh, + equipmentBoardNewSwActivatedButNotRestarted, + equipmentBoardLowTemperature, + equipmentBoardTempLowThreshold, + equipmentBoardAdditionalInfo } + STATUS deprecated + DESCRIPTION + "The board objects V10. (17.0)" + ::= { lumEquipmentGroups 37 } + +equipmentNodeGroupV10 OBJECT-GROUP + OBJECTS { + equipmentNodeLedTest, + equipmentNodeIcnRedundancyMode, + equipmentNodeMemoryProfile, + equipmentAllowDummyPassiveSlots, + equipmentNodeManagementVlan, + equipmentNodeMgmtVlanPrivacy, + equipmentNodeDcnRedundancyMode} + STATUS deprecated + DESCRIPTION + "The node objects V10 (18.0)" + ::= { lumEquipmentGroups 38 } + +equipmentBoardGroupV11 OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardTemp, + equipmentBoardLedTest, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardRowStatus, + equipmentBoardLastChangeTime, + equipmentBoardMissing, + equipmentBoardUnexpectedType, + equipmentBoardTempHighExceeded, + equipmentBoardCommunicationFailure, + equipmentBoardInterworkFailed, + equipmentBoardSecondaryPowerFailed, + equipmentBoardVitalDataMissing, + equipmentBoardNonVitalDataMissing, + equipmentBoardUnderMaintenance, + equipmentBoardTempThreshold, + equipmentBoardSwVersionMismatch, + equipmentBoardObjectProperty, + equipmentBoardReconfigure, + equipmentBoardLedStatus, + equipmentBoardModuleInfo, + equipmentBoardTempLow, + equipmentBoardTempVeryHigh, + equipmentBoardNewSwActivatedButNotRestarted, + equipmentBoardLowTemperature, + equipmentBoardTempLowThreshold, + equipmentBoardAdditionalInfo, + equipmentBoardBootError, + equipmentBoardHardwareError, + equipmentBoardLowDiskSpace, + equipmentBoardClockDrift } + STATUS deprecated + DESCRIPTION + "The board objects V11. (20.0)" + ::= { lumEquipmentGroups 40 } + +equipmentFanGroupV4 OBJECT-GROUP + OBJECTS { + equipmentFanIndex, + equipmentFanName, + equipmentFanSubrack, + equipmentFanSlot, + equipmentFanInvPhysIndexOrZero, + equipmentFanAdminStatus, + equipmentFanOperStatus, + equipmentFanRowStatus, + equipmentFanUnitFailed, + equipmentFanMainUnitFailed, + equipmentFanObjectProperty, + equipmentFanFanFault } + STATUS deprecated + DESCRIPTION + "The fan module objects V4. (20.0)" + ::= { lumEquipmentGroups 41 } + +equipmentSlotGroup OBJECT-GROUP + OBJECTS { + equipmentSlotIndex, + equipmentSlotName, + equipmentSlotSubrack, + equipmentSlotSlot, + equipmentSlotAdminStatus, + equipmentSlotUsageState, + equipmentSlotEmptySlot } + STATUS deprecated + DESCRIPTION + "The slot module objects. (20.0)" + ::= { lumEquipmentGroups 42 } + +equipmentBoardGroupV12 OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardTemp, + equipmentBoardLedTest, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardRowStatus, + equipmentBoardLastChangeTime, + equipmentBoardMissing, + equipmentBoardUnexpectedType, + equipmentBoardTempHighExceeded, + equipmentBoardCommunicationFailure, + equipmentBoardInterworkFailed, + equipmentBoardSecondaryPowerFailed, + equipmentBoardVitalDataMissing, + equipmentBoardNonVitalDataMissing, + equipmentBoardUnderMaintenance, + equipmentBoardTempThreshold, + equipmentBoardSwVersionMismatch, + equipmentBoardObjectProperty, + equipmentBoardReconfigure, + equipmentBoardLedStatus, + equipmentBoardModuleInfo, + equipmentBoardTempLow, + equipmentBoardTempVeryHigh, + equipmentBoardNewSwActivatedButNotRestarted, + equipmentBoardLowTemperature, + equipmentBoardTempLowThreshold, + equipmentBoardAdditionalInfo, + equipmentBoardBootError, + equipmentBoardHardwareError, + equipmentBoardLowDiskSpace, + equipmentBoardClockDrift, + equipmentBoardPostponeFwUpgrade, + equipmentBoardActivatePendingFwCommand, + equipmentBoardFwActivationPending, + equipmentBoardFeatureNotSupported } + STATUS deprecated + DESCRIPTION + "The board objects V12. (21.0)" + ::= { lumEquipmentGroups 43 } + + +equipmentNodeGroupV11 OBJECT-GROUP + OBJECTS { + equipmentNodeLedTest, + equipmentNodeIcnRedundancyMode, + equipmentNodeMemoryProfile, + equipmentAllowDummyPassiveSlots, + equipmentNodeManagementVlan, + equipmentNodeMgmtVlanPrivacy, + equipmentNodeDcnRedundancyMode, + equipmentNodeProxyArp} + STATUS current + DESCRIPTION + "The node objects V11 (21.0)" + ::= { lumEquipmentGroups 44 } + +equipmentBoardGroupV13 OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardTemp, + equipmentBoardLedTest, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardRowStatus, + equipmentBoardLastChangeTime, + equipmentBoardMissing, + equipmentBoardUnexpectedType, + equipmentBoardTempHighExceeded, + equipmentBoardCommunicationFailure, + equipmentBoardInterworkFailed, + equipmentBoardSecondaryPowerFailed, + equipmentBoardVitalDataMissing, + equipmentBoardNonVitalDataMissing, + equipmentBoardUnderMaintenance, + equipmentBoardTempThreshold, + equipmentBoardSwVersionMismatch, + equipmentBoardObjectProperty, + equipmentBoardReconfigure, + equipmentBoardLedStatus, + equipmentBoardModuleInfo, + equipmentBoardTempLow, + equipmentBoardTempVeryHigh, + equipmentBoardNewSwActivatedButNotRestarted, + equipmentBoardLowTemperature, + equipmentBoardTempLowThreshold, + equipmentBoardAdditionalInfo, + equipmentBoardBootError, + equipmentBoardHardwareError, + equipmentBoardLowDiskSpace, + equipmentBoardClockDrift, + equipmentBoardPostponeFwUpgrade, + equipmentBoardActivatePendingFwCommand, + equipmentBoardFwActivationPending, + equipmentBoardFeatureNotSupported, + equipmentBoardFwReloadNeeded, + equipmentBoardFwContextUnknown, + equipmentBoardBoardVariant, + equipmentBoardCabinetConnectivity, + equipmentBoardCabinetConnectionFailure } + STATUS deprecated + DESCRIPTION + "The board objects V13. (27.0)" + ::= { lumEquipmentGroups 45 } + +equipmentPowerGroupV3 OBJECT-GROUP + OBJECTS { + equipmentPowerIndex, + equipmentPowerName, + equipmentPowerSubrack, + equipmentPowerSlot, + equipmentPowerType, + equipmentPowerInvPhysIndexOrZero, + equipmentPowerAdminStatus, + equipmentPowerOperStatus, + equipmentPowerRowStatus, + equipmentPowerACPowerFailed, + equipmentPowerDCPowerFailed, + equipmentPowerTemperatureHigh, + equipmentPowerModuleMissing, + equipmentPowerObjectProperty, + equipmentPowerDCPowerFailedSeverity } + STATUS deprecated + DESCRIPTION + "The power module objects V3 (27.0)." + ::= { lumEquipmentGroups 46 } + +equipmentBoardGroupV14 OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardTemp, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardLedTest, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardLastChangeTime, + equipmentBoardRowStatus, + equipmentBoardMissing, + equipmentBoardUnexpectedType, + equipmentBoardTempHighExceeded, + equipmentBoardCommunicationFailure, + equipmentBoardInterworkFailed, + equipmentBoardSecondaryPowerFailed, + equipmentBoardVitalDataMissing, + equipmentBoardNonVitalDataMissing, + equipmentBoardUnderMaintenance, + equipmentBoardTempThreshold, + equipmentBoardSwVersionMismatch, + equipmentBoardObjectProperty, + equipmentBoardTempLow, + equipmentBoardTempVeryHigh, + equipmentBoardReconfigure, + equipmentBoardLedStatus, + equipmentBoardModuleInfo, + equipmentBoardNewSwActivatedButNotRestarted, + equipmentBoardLowTemperature, + equipmentBoardTempLowThreshold, + equipmentBoardAdditionalInfo, + equipmentBoardBootError, + equipmentBoardHardwareError, + equipmentBoardLowDiskSpace, + equipmentBoardClockDrift, + equipmentBoardPostponeFwUpgrade, + equipmentBoardActivatePendingFwCommand, + equipmentBoardFwActivationPending, + equipmentBoardFeatureNotSupported, + equipmentBoardFwReloadNeeded, + equipmentBoardFwContextUnknown, + equipmentBoardBoardVariant, + equipmentBoardCabinetConnectivity, + equipmentBoardCabinetConnectionFailure, + equipmentBoardOperationalVariant, + equipmentBoardAid, + equipmentBoardPhysicalLocation} + STATUS current + DESCRIPTION + "The board objects V14. (28.0)" + ::= { lumEquipmentGroups 47 } + +equipmentSlotGroupV2 OBJECT-GROUP + OBJECTS { + equipmentSlotIndex, + equipmentSlotName, + equipmentSlotSubrack, + equipmentSlotSlot, + equipmentSlotAdminStatus, + equipmentSlotUsageState, + equipmentSlotEmptySlot, + equipmentSlotEquipped, + equipmentSlotAid, + equipmentSlotPhysicalLocation + } + STATUS current + DESCRIPTION + "The slot module objects V2. (28.0)" + ::= { lumEquipmentGroups 48 } + +equipmentSubrackGroupV9 OBJECT-GROUP + OBJECTS { + equipmentSubrackIndex, + equipmentSubrackName, + equipmentSubrackSubrack, + equipmentSubrackDescr, + equipmentSubrackInvPhysIndexOrZero, + equipmentSubrackAllFanUnitsFailed, + equipmentSubrackRowStatus, + equipmentSubrackActualType, + equipmentSubrackExpectedType, + equipmentSubrackUnexpectedType, + equipmentSubrackTemp, + equipmentSubrackTempHighExceeded, + equipmentSubrackTempThreshold, + equipmentSubrackDataChanged, + equipmentSubrackSystemModeSet, + equipmentSubrackEffectiveSystemMode, + equipmentSubrackCurrentSystemMode, + equipmentSubrackAdminStatus, + equipmentSubrackOperStatus, + equipmentSubrackObjectProperty, + equipmentSubrackShelfLength, + equipmentSubrackLANModuleMissing, + equipmentSubrackExpectedFirstPbSlot, + equipmentSubrackActualFirstPbSlot, + equipmentSubrackFirstPbSlotMismatch, + equipmentSubrackAid, + equipmentSubrackPhysicalLocation} + STATUS deprecated + DESCRIPTION + "The subrack module objects V9. (28.0)" + ::= { lumEquipmentGroups 49 } + +equipmentPowerGroupV4 OBJECT-GROUP + OBJECTS { + equipmentPowerIndex, + equipmentPowerName, + equipmentPowerSubrack, + equipmentPowerSlot, + equipmentPowerType, + equipmentPowerInvPhysIndexOrZero, + equipmentPowerAdminStatus, + equipmentPowerOperStatus, + equipmentPowerRowStatus, + equipmentPowerACPowerFailed, + equipmentPowerDCPowerFailed, + equipmentPowerTemperatureHigh, + equipmentPowerModuleMissing, + equipmentPowerObjectProperty, + equipmentPowerDCPowerFailedSeverity, + equipmentPowerAid, + equipmentPowerPhysicalLocation} + STATUS deprecated + DESCRIPTION + "The power module objects V4 (28.0)." + ::= { lumEquipmentGroups 50 } + +equipmentFanGroupV5 OBJECT-GROUP + OBJECTS { + equipmentFanIndex, + equipmentFanName, + equipmentFanSubrack, + equipmentFanSlot, + equipmentFanInvPhysIndexOrZero, + equipmentFanAdminStatus, + equipmentFanOperStatus, + equipmentFanRowStatus, + equipmentFanUnitFailed, + equipmentFanMainUnitFailed, + equipmentFanObjectProperty, + equipmentFanFanFault, + equipmentFanAid, + equipmentFanPhysicalLocation} + STATUS current + DESCRIPTION + "The fan module objects V5. (28.0)" + ::= { lumEquipmentGroups 51 } + +equipmentGeneralGroupV5 OBJECT-GROUP + OBJECTS { + equipmentGeneralLastChangeTime, + equipmentGeneralStateLastChangeTime, + equipmentGeneralEquipmentSubrackTableSize, + equipmentGeneralEquipmentBoardTableSize, + equipmentGeneralEquipmentPowerTableSize, + equipmentGeneralEquipmentFanTableSize, + equipmentGeneralEquipmentSlotTableSize } + STATUS deprecated + DESCRIPTION + "The equipment general objects v5 (R28.0)." + ::= { lumEquipmentGroups 52 } + +equipmentSubrackGroupV10 OBJECT-GROUP + OBJECTS { + equipmentSubrackIndex, + equipmentSubrackName, + equipmentSubrackSubrack, + equipmentSubrackDescr, + equipmentSubrackInvPhysIndexOrZero, + equipmentSubrackAllFanUnitsFailed, + equipmentSubrackRowStatus, + equipmentSubrackActualType, + equipmentSubrackExpectedType, + equipmentSubrackUnexpectedType, + equipmentSubrackTemp, + equipmentSubrackTempHighExceeded, + equipmentSubrackTempThreshold, + equipmentSubrackDataChanged, + equipmentSubrackSystemModeSet, + equipmentSubrackEffectiveSystemMode, + equipmentSubrackCurrentSystemMode, + equipmentSubrackAdminStatus, + equipmentSubrackOperStatus, + equipmentSubrackObjectProperty, + equipmentSubrackShelfLength, + equipmentSubrackLANModuleMissing, + equipmentSubrackExpectedFirstPbSlot, + equipmentSubrackActualFirstPbSlot, + equipmentSubrackFirstPbSlotMismatch, + equipmentSubrackAid, + equipmentSubrackPhysicalLocation, + equipmentSubrackChangeExpectedType} + STATUS current + DESCRIPTION + "The subrack module objects V10. (29.0)" + ::= { lumEquipmentGroups 53 } + +equipmentGeneralGroupV6 OBJECT-GROUP + OBJECTS { + equipmentGeneralLastChangeTime, + equipmentGeneralStateLastChangeTime, + equipmentGeneralEquipmentSubrackTableSize, + equipmentGeneralEquipmentBoardTableSize, + equipmentGeneralEquipmentPowerTableSize, + equipmentGeneralEquipmentFanTableSize, + equipmentGeneralEquipmentSlotTableSize, + equipmentGeneralEquipmentOpticalModuleTableSize } + STATUS current + DESCRIPTION + "The equipment general objects v6 (R31.0)." + ::= { lumEquipmentGroups 54 } + +equipmentOpticalModuleGroup OBJECT-GROUP + OBJECTS { + equipmentOpticalModuleIndex, + equipmentOpticalModuleHostBoardType, + equipmentOpticalModuleType, + equipmentOpticalModuleName, + equipmentOpticalModuleSubrack, + equipmentOpticalModuleSlot, + equipmentOpticalModuleFirmwareVersion, + equipmentOpticalModuleSerialNumber, + equipmentOpticalModuleWarmingUpState, + equipmentOpticalModuleFailure + } + STATUS current + DESCRIPTION + "The equipment optical module objects v6 (R31.0)." + ::= { lumEquipmentGroups 55 } + +equipmentPowerGroupV5 OBJECT-GROUP + OBJECTS { + equipmentPowerIndex, + equipmentPowerName, + equipmentPowerSubrack, + equipmentPowerSlot, + equipmentPowerType, + equipmentPowerInvPhysIndexOrZero, + equipmentPowerAdminStatus, + equipmentPowerOperStatus, + equipmentPowerRowStatus, + equipmentPowerPowerFailed, + equipmentPowerTemperatureHigh, + equipmentPowerModuleMissing, + equipmentPowerObjectProperty, + equipmentPowerDCPowerFailedSeverity, + equipmentPowerAid, + equipmentPowerPhysicalLocation} + STATUS current + DESCRIPTION + "The power module objects V5 (32.1)." + ::= { lumEquipmentGroups 56 } + +-- ---------------------------------------------------- +-- Compliance +-- ---------------------------------------------------- + +lumEquipmentBasicComplV1 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB." + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroup, + equipmentSubrackGroup, + equipmentBoardGroup, + equipmentPowerGroup, + equipmentFanGroup } + ::= { lumEquipmentCompl 1 } + +lumEquipmentBasicComplV2 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V2." + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV2, + equipmentSubrackGroup, + equipmentBoardGroup, + equipmentPowerGroup, + equipmentFanGroup } + ::= { lumEquipmentCompl 2 } + +lumEquipmentBasicComplV3 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V3." + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV2, + equipmentSubrackGroup, + equipmentBoardGroup, + equipmentPowerGroup, + equipmentFanGroup, + equipmentNotificationGroup } + ::= { lumEquipmentCompl 3 } + +lumEquipmentBasicComplV4 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V4." + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV2, + equipmentSubrackGroupV2, + equipmentBoardGroup, + equipmentPowerGroup, + equipmentFanGroup, + equipmentNotificationGroup } + ::= { lumEquipmentCompl 4 } + +lumEquipmentBasicComplV5 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V5." + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV2, + equipmentSubrackGroupV3, + equipmentBoardGroup, + equipmentPowerGroup, + equipmentFanGroup, + equipmentNotificationGroup } + ::= { lumEquipmentCompl 5 } + +lumEquipmentBasicComplV6 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V6." + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV2, + equipmentSubrackGroupV3, + equipmentBoardGroupV2, + equipmentPowerGroup, + equipmentFanGroup, + equipmentNotificationGroup } + ::= { lumEquipmentCompl 6 } + +lumEquipmentBasicComplV7 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V7." + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV2, + equipmentSubrackGroupV3, + equipmentBoardGroupV2, + equipmentPowerGroup, + equipmentFanGroup, + equipmentNotificationGroup, + equipmentNodeGroup } + ::= { lumEquipmentCompl 7 } + +lumEquipmentBasicComplV8 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V8." + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV3, + equipmentSubrackGroupV3, + equipmentBoardGroupV2, + equipmentPowerGroup, + equipmentFanGroup, + equipmentNotificationGroup, + equipmentNodeGroup } + ::= { lumEquipmentCompl 8 } + +lumEquipmentBasicComplV9 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V9." + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV3, + equipmentSubrackGroupV3, + equipmentBoardGroupV2, + equipmentPowerGroup, + equipmentFanGroup, + equipmentNotificationGroup, + equipmentNodeGroupV2 } + ::= { lumEquipmentCompl 9 } + +lumEquipmentBasicComplV10 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V10." + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV3, + equipmentSubrackGroupV3, + equipmentBoardGroupV2, + equipmentPowerGroup, + equipmentFanGroup, + equipmentNotificationGroup, + equipmentNodeGroupV3 } + ::= { lumEquipmentCompl 10 } + +lumEquipmentBasicComplV11 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V11. + Equivalent to V10, but the notifications differ..." + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV3, + equipmentSubrackGroupV3, + equipmentBoardGroupV2, + equipmentPowerGroup, + equipmentFanGroup, + equipmentNotificationGroup, + equipmentNodeGroupV3 } + ::= { lumEquipmentCompl 11 } + +lumEquipmentBasicComplV12 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V12." + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV3, + equipmentSubrackGroupV4, + equipmentBoardGroupV3, + equipmentPowerGroup, + equipmentFanGroup, + equipmentNotificationGroupV2, + equipmentNodeGroupV3 } + ::= { lumEquipmentCompl 12 } + +lumEquipmentBasicComplV13 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V13. (2.2)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV3, + equipmentSubrackGroupV5, + equipmentBoardGroupV3, + equipmentPowerGroup, + equipmentFanGroup, + equipmentNotificationGroupV2, + equipmentNodeGroupV3 } + ::= { lumEquipmentCompl 13 } + +lumEquipmentBasicComplV14 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V14. (2.3)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV3, + equipmentSubrackGroupV5, + equipmentBoardGroupV3, + equipmentPowerGroup, + equipmentFanGroup, + equipmentNotificationGroupV2, + equipmentNodeGroupV3 } + ::= { lumEquipmentCompl 14 } + +lumEquipmentBasicComplV15 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V15. (2.3.2)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV3, + equipmentSubrackGroupV5, + equipmentBoardGroupV3, + equipmentPowerGroup, + equipmentFanGroupV2, + equipmentNotificationGroupV2, + equipmentNodeGroupV3 } + ::= { lumEquipmentCompl 15 } + +lumEquipmentBasicComplV16 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V16. (3.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV3, + equipmentSubrackGroupV5, + equipmentBoardGroupV3, + equipmentPowerGroup, + equipmentFanGroupV2, + equipmentNotificationGroupV2, + equipmentNodeGroupV3 } + ::= { lumEquipmentCompl 16 } + +lumEquipmentBasicComplV17 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V17. (3.1)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV5, + equipmentBoardGroupV3, + equipmentPowerGroup, + equipmentFanGroupV2, + equipmentNotificationGroupV2, + equipmentNodeGroupV3 } + ::= { lumEquipmentCompl 17 } + +lumEquipmentBasicComplV18 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V18. (4.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV6, + equipmentBoardGroupV4, + equipmentPowerGroupV2, + equipmentFanGroupV3, + equipmentNotificationGroupV2, + equipmentNodeGroupV3 } + ::= { lumEquipmentCompl 18 } + +lumEquipmentBasicComplV19 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V19. (7.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV6, + equipmentBoardGroupV5, + equipmentPowerGroupV2, + equipmentFanGroupV3, + equipmentNotificationGroupV2, + equipmentNodeGroupV4 } + ::= { lumEquipmentCompl 19 } + +lumEquipmentBasicComplV20 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V20. (8.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV6, + equipmentBoardGroupV6, + equipmentPowerGroupV2, + equipmentFanGroupV3, + equipmentNotificationGroupV2, + equipmentNodeGroupV4 } + ::= { lumEquipmentCompl 20 } + +lumEquipmentBasicComplV21 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V21. (9.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV6, + equipmentBoardGroupV7, + equipmentPowerGroupV2, + equipmentFanGroupV3, + equipmentNotificationGroupV2, + equipmentNodeGroupV4 } + ::= { lumEquipmentCompl 21 } + +lumEquipmentBasicComplV22 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V22. (10.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV6, + equipmentBoardGroupV7, + equipmentPowerGroupV2, + equipmentFanGroupV3, + equipmentNotificationGroupV2, + equipmentNodeGroupV4 } + ::= { lumEquipmentCompl 22 } + +lumEquipmentBasicComplV23 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V23. (11.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV6, + equipmentBoardGroupV7, + equipmentPowerGroupV2, + equipmentFanGroupV3, + equipmentNotificationGroupV2, + equipmentNodeGroupV8 } + ::= { lumEquipmentCompl 23 } + +lumEquipmentBasicComplV24 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V24. (12.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV6, + equipmentBoardGroupV8, + equipmentPowerGroupV2, + equipmentFanGroupV3, + equipmentNotificationGroupV2, + equipmentNodeGroupV8 } + ::= { lumEquipmentCompl 24 } + +lumEquipmentBasicComplV25 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V24. (14.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV6, + equipmentBoardGroupV8, + equipmentPowerGroupV2, + equipmentFanGroupV3, + equipmentNotificationGroupV2, + equipmentNodeGroupV9 } + ::= { lumEquipmentCompl 25 } + +lumEquipmentBasicComplV26 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V26. (16.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV6, + equipmentBoardGroupV8, + equipmentPowerGroupV2, + equipmentFanGroupV3, + equipmentNotificationGroupV2, + equipmentNodeGroupV9, + equipmentResourceGroup } + ::= { lumEquipmentCompl 26 } + +lumEquipmentBasicComplV27 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V26. (16.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV7, + equipmentBoardGroupV8, + equipmentPowerGroupV2, + equipmentFanGroupV3, + equipmentNotificationGroupV2, + equipmentNodeGroupV9, + equipmentResourceGroup } + ::= { lumEquipmentCompl 27 } + +lumEquipmentBasicComplV28 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V28. (17.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV8, + equipmentBoardGroupV9, + equipmentPowerGroupV2, + equipmentFanGroupV3, + equipmentNotificationGroupV3, + equipmentNodeGroupV9, + equipmentResourceGroup } + ::= { lumEquipmentCompl 28 } + +lumEquipmentBasicComplV29 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V28. (17.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV8, + equipmentBoardGroupV10, + equipmentPowerGroupV2, + equipmentFanGroupV3, + equipmentNotificationGroupV3, + equipmentNodeGroupV9, + equipmentResourceGroup } + ::= { lumEquipmentCompl 29 } + +lumEquipmentBasicComplV30 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V30. (18.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV8, + equipmentBoardGroupV10, + equipmentPowerGroupV2, + equipmentFanGroupV3, + equipmentNotificationGroupV3, + equipmentNodeGroupV10, + equipmentResourceGroup } + ::= { lumEquipmentCompl 30 } + +lumEquipmentBasicComplV31 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V31. (20.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV8, + equipmentBoardGroupV11, + equipmentPowerGroupV2, + equipmentFanGroupV4, + equipmentNotificationGroupV3, + equipmentNodeGroupV10, + equipmentResourceGroup, + equipmentSlotGroup } + ::= { lumEquipmentCompl 31 } + +lumEquipmentBasicComplV32 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V32. (21.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV8, + equipmentBoardGroupV12, + equipmentPowerGroupV2, + equipmentFanGroupV4, + equipmentNotificationGroupV3, + equipmentNodeGroupV11, + equipmentResourceGroup, + equipmentSlotGroup } + ::= { lumEquipmentCompl 32 } + +lumEquipmentBasicComplV33 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V33. (27.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV4, + equipmentSubrackGroupV8, + equipmentBoardGroupV13, + equipmentPowerGroupV3, + equipmentFanGroupV4, + equipmentNotificationGroupV3, + equipmentNodeGroupV11, + equipmentResourceGroup, + equipmentSlotGroup } + ::= { lumEquipmentCompl 33 } + +lumEquipmentBasicComplV34 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Basic implementation requirements for the equipment MIB V34. (28.0)" + MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV5, + equipmentSubrackGroupV9, + equipmentBoardGroupV14, + equipmentPowerGroupV4, + equipmentFanGroupV5, + equipmentNotificationGroupV3, + equipmentNodeGroupV11, + equipmentResourceGroup, + equipmentSlotGroupV2 } + ::= { lumEquipmentCompl 34 } + +lumEquipmentBasicComplV35 MODULE-COMPLIANCE +STATUS deprecated +DESCRIPTION + "Basic implementation requirements for the equipment MIB V35. (29.0)" +MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV5, + equipmentSubrackGroupV10, + equipmentBoardGroupV14, + equipmentPowerGroupV4, + equipmentFanGroupV5, + equipmentNotificationGroupV3, + equipmentNodeGroupV11, + equipmentResourceGroup, + equipmentSlotGroupV2 } +::= { lumEquipmentCompl 35 } + +lumEquipmentBasicComplV36 MODULE-COMPLIANCE +STATUS deprecated +DESCRIPTION + "Basic implementation requirements for the equipment MIB V36. (31.0)" +MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV6, + equipmentSubrackGroupV10, + equipmentBoardGroupV14, + equipmentPowerGroupV4, + equipmentFanGroupV5, + equipmentNotificationGroupV3, + equipmentNodeGroupV11, + equipmentResourceGroup, + equipmentSlotGroupV2, + equipmentOpticalModuleGroup} +::= { lumEquipmentCompl 36 } + +lumEquipmentBasicComplV37 MODULE-COMPLIANCE +STATUS current +DESCRIPTION + "Basic implementation requirements for the equipment MIB V37. (32.1)" +MODULE + MANDATORY-GROUPS { + equipmentGeneralGroupV6, + equipmentSubrackGroupV10, + equipmentBoardGroupV14, + equipmentPowerGroupV5, + equipmentFanGroupV5, + equipmentNotificationGroupV3, + equipmentNodeGroupV11, + equipmentResourceGroup, + equipmentSlotGroupV2, + equipmentOpticalModuleGroup} +::= { lumEquipmentCompl 37 } + +-- ---------------------------------------------------- +-- Object and event groups +-- ---------------------------------------------------- + +equipmentGeneralMinimalGroupV1 OBJECT-GROUP + OBJECTS { + equipmentGeneralLastChangeTime, + equipmentGeneralStateLastChangeTime, + equipmentGeneralEquipmentBoardTableSize } + STATUS current + DESCRIPTION + "The minimal general equipment MIB objects." + ::= { lumEquipmentMinimalGroups 1 } + +equipmentBoardMinimalGroupV1 OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardTemp, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardRowStatus } + STATUS deprecated + DESCRIPTION + "The minimal board objects." + ::= { lumEquipmentMinimalGroups 2 } + +equipmentBoardMinimalGroupV2 OBJECT-GROUP + OBJECTS { + equipmentBoardIndex, + equipmentBoardName, + equipmentBoardSubrack, + equipmentBoardSlot, + equipmentBoardInvPhysIndexOrZero, + equipmentBoardExpectedType, + equipmentBoardActualType, + equipmentBoardDescr, + equipmentBoardTemp, + equipmentBoardAdminStatus, + equipmentBoardOperStatus, + equipmentBoardRowStatus, + equipmentBoardTempLow, + equipmentBoardTempVeryHigh } + STATUS current + DESCRIPTION + "The minimal board objects." + ::= { lumEquipmentMinimalGroups 3 } + + +-- ---------------------------------------------------- +-- Minimal Compliance +-- ---------------------------------------------------- + +lumEquipmentMinimalComplV1 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Minimal implementation requirements for the equipment MIB V1." + MODULE + MANDATORY-GROUPS { + equipmentGeneralMinimalGroupV1, + equipmentBoardMinimalGroupV1 } + ::= { lumEquipmentMinimalCompl 1 } + +lumEquipmentMinimalComplV2 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Minimal implementation requirements for the equipment MIB V2." + MODULE + MANDATORY-GROUPS { + equipmentGeneralMinimalGroupV1, + equipmentBoardMinimalGroupV2, + equipmentSubrackGroupV6, + equipmentPowerGroupV2 } + ::= { lumEquipmentMinimalCompl 2 } + +lumEquipmentMinimalComplV3 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Minimal implementation requirements for the equipment MIB V3." + MODULE + MANDATORY-GROUPS { + equipmentGeneralMinimalGroupV1, + equipmentBoardMinimalGroupV2, + equipmentSubrackGroupV6, + equipmentPowerGroupV2, + equipmentFanGroupV2 } + ::= { lumEquipmentMinimalCompl 3 } + +lumEquipmentMinimalComplV4 MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "Minimal implementation requirements for the equipment MIB V4." + MODULE + MANDATORY-GROUPS { + equipmentGeneralMinimalGroupV1, + equipmentBoardMinimalGroupV2, + equipmentSubrackGroupV7, + equipmentPowerGroupV2, + equipmentFanGroupV2 } + ::= { lumEquipmentMinimalCompl 4 } + +lumEquipmentMinimalComplV5 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "Minimal implementation requirements for the equipment MIB V5." + MODULE + MANDATORY-GROUPS { + equipmentGeneralMinimalGroupV1, + equipmentBoardMinimalGroupV2, + equipmentSubrackGroupV8, + equipmentPowerGroupV2, + equipmentFanGroupV2 } + ::= { lumEquipmentMinimalCompl 5 } + +lumEquipmentMinimalComplV6 MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "Minimal implementation requirements for the equipment MIB V6." + MODULE + MANDATORY-GROUPS { + equipmentGeneralMinimalGroupV1, + equipmentBoardMinimalGroupV2, + equipmentSubrackGroupV8, + equipmentPowerGroupV3, + equipmentFanGroupV2 } + ::= { lumEquipmentMinimalCompl 6 } + +END + + + |