diff options
Diffstat (limited to 'MIBS/jacarta/InterSeptor-MIB')
| -rw-r--r-- | MIBS/jacarta/InterSeptor-MIB | 1580 |
1 files changed, 1580 insertions, 0 deletions
diff --git a/MIBS/jacarta/InterSeptor-MIB b/MIBS/jacarta/InterSeptor-MIB new file mode 100644 index 0000000..fe255f4 --- /dev/null +++ b/MIBS/jacarta/InterSeptor-MIB @@ -0,0 +1,1580 @@ +-- Jacarta interSeptor MIB +-- MIB for interSeptor Environmental Monitoring System +-- +-- { iso org(3) dod(6) internet(1) private(4) enterprises(1) jacarta(19011) +-- product(1) webAppliance(3) inSept(1) +-- ============================================================================================== +--- +--- Revision History +--- +--- V1.00 - Initial Release - July 03 +--- V1.01 - Minor SNMP bug fix - Aug 03 +--- v1.10 - Add temperature unit object - Oct, 15 2004 +--- Add date format object +--- Add inSeptConfigAccessControlTable +--- Add object +--- v1.11 Change interSeptor-MIB to InterSeptor-MIB - Dec, 20 2004 +--- Updated InSeptsensorConfigSensorEntry and SensorMonitorSensorEntry +--- V1.12 - Modified syntax error - May, 10 2005 +--- Fixed SYNTAX InSeptConfigTrapsReceiversEntry +--- Changed SYNTAX inSeptConfigTrapsReceiversEntry to SYNTAX InSeptConfigTrapsReceiversEntry +--- V1.13 - Modified syntax error - June, 27 2006 +--- Check error form http://wwwsnmp.cs.utwente.nl/ietf/mibs/validate/ +--- =========================================================================================== +InterSeptor-MIB DEFINITIONS ::= BEGIN + +IMPORTS + enterprises + FROM RFC1155-SMI + OBJECT-TYPE + FROM RFC-1212 + DisplayString + FROM RFC1213-MIB + TRAP-TYPE + FROM RFC-1215; + +jacarta OBJECT IDENTIFIER ::= { enterprises 19011 } +product OBJECT IDENTIFIER ::= { jacarta 1 } +webAppliance OBJECT IDENTIFIER ::= { product 3 } +inSept OBJECT IDENTIFIER ::= { webAppliance 1} +inSeptObjects OBJECT IDENTIFIER ::= { inSept 1 } +inSeptTraps OBJECT IDENTIFIER ::= { inSept 2 } + +inSeptIdent OBJECT IDENTIFIER ::= { inSeptObjects 1 } +inSeptConfig OBJECT IDENTIFIER ::= { inSeptObjects 2 } +inSeptsensorMonitor OBJECT IDENTIFIER ::= { inSeptObjects 3 } +inSeptsensorConfig OBJECT IDENTIFIER ::= { inSeptObjects 4 } + +-- =========================================================================== +-- +-- inSeptIdentification +-- +-- All objects in this group except for inSeptIdentName and +-- inSeptIdentAttachedDevices are set at device initialization +-- and remain static. +-- +-- =========================================================================== + +inSeptIdentManufacturer OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..31)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The name of the interSeptor manufacturer." + ::= { inSeptIdent 1 } + +inSeptIdentModel OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..63)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The interSeptor Model designation." + ::= { inSeptIdent 2 } + +inSeptIdentAgentSoftwareVersion OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..31)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The interSeptor software/firmware version." + ::= { inSeptIdent 3 } + +inSeptIdentName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..31)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A string identifying the interSeptor. This object should be + set by the administrator." + ::= { inSeptIdent 4 } + +-- =========================================================================== +-- +-- inSeptConfig +-- +-- =========================================================================== + +inSeptConfigMibVersion OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The version of MIB spec." + ::= { inSeptConfig 1} + +inSeptConfigNetwork OBJECT IDENTIFIER ::= { inSeptConfig 2 } + +inSeptConfigIpAddress OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + " The ip address that NMS can identify the managed + device" + ::= { inSeptConfigNetwork 1 } + +inSeptConfigGateway OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + " The default gateway that allows the device to be managed + through routers " + ::= { inSeptConfigNetwork 2 } + +inSeptConfigSubnetMask OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + " Internet address subnet mask" + ::= { inSeptConfigNetwork 3 } + +inSeptConfigDateTime OBJECT IDENTIFIER ::= { inSeptConfig 3 } + +inSeptConfigDate OBJECT-TYPE + SYNTAX DisplayString (SIZE (10..10)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The date in inSept, format is (dd/mm/yyyy)" + ::= { inSeptConfigDateTime 1} + +inSeptConfigTime OBJECT-TYPE + SYNTAX DisplayString (SIZE (8..8)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The time in interSeptor, format is (hh:mm:ss)" + ::= { inSeptConfigDateTime 2} + +inSeptConfigTimeFromNtp OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable update date/time from NTP server." + ::= { inSeptConfigDateTime 3} + +inSeptConfigNtpIpAddress OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "NTP IP address." + ::= { inSeptConfigDateTime 4} + +inSeptConfigNtpTimeZone OBJECT-TYPE + SYNTAX INTEGER { + gMT-1200(1), + gMT-1100(2), + gMT-1000(3), + gMT-0900(4), + gMT-0800(5), + gMT-0700(6), + gMT-0600(7), + gMT-0500(8), + gMT-0400(9), + gMT-0330(10), + gMT-0300(11), + gMT-0200(12), + gMT-0100(13), + gMT-0000(14), + gMT0100(15), + gMT0200(16), + gMT0300(17), + gMT0330(18), + gMT0400(19), + gMT0500(20), + gMT0530(21), + gMT0600(22), + gMT0700(23), + gMT0800(24), + gMT0900(25), + gMT1000(26), + gMT1100(27), + gMT1200(28) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable update date/time from NTP server." + ::= { inSeptConfigDateTime 5} + +inSeptConfigDayLightSaving OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable daylight saving for NTP time, if enabled, the time get from NTP will be set + set one hour in advance to reflect daylight saving status." + ::= { inSeptConfigDateTime 6} + +inSeptConfigLog OBJECT IDENTIFIER ::= { inSeptConfig 4 } + +inSeptConfigHistoryLogFrequency OBJECT-TYPE + SYNTAX INTEGER (5..3600) -- in seconds + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The frequency of the update of the history log. The value + is in seconds" + ::= { inSeptConfigLog 1} + +inSeptConfigExtHistoryLogFrequency OBJECT-TYPE + SYNTAX INTEGER (1..1440) -- in minutes + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The frequency of the update of the extended history log. + The value is in seconds" + ::= { inSeptConfigLog 2} + +inSeptConfigConfigurationLog OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + " Enable/disable inSept to log parameter change." + ::= { inSeptConfigLog 3} + +inSeptConfigDhcpStatue OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable DHCP/BootP capability" + ::= { inSeptConfig 5} + +inSeptConfigPingStatue OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable Ping Echo capability" + ::= { inSeptConfig 6} + +inSeptConfigTftpStatue OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable TFTP network upgrade capability" + ::= { inSeptConfig 7} + +inSeptConfigTelnet OBJECT IDENTIFIER ::= { inSeptConfig 8 } + +inSeptConfigTelnetStatue OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable telnet access" + ::= { inSeptConfigTelnet 1} + +inSeptConfigTelnetPortNumber OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting the server port of telnet." + ::= { inSeptConfigTelnet 2} + +inSeptConfigHttp OBJECT IDENTIFIER ::= { inSeptConfig 9 } + +inSeptConfigHttpStatue OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable HTTP access" + ::= { inSeptConfigHttp 1} + +inSeptConfigHttpPortNumber OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting the server port of HTTP." + ::= { inSeptConfigHttp 2} + +inSeptConfigHttpSecurity OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable HTTP access for read-only users" + ::= { inSeptConfigHttp 3} + + +inSeptConfigSnmp OBJECT IDENTIFIER ::= { inSeptConfig 10 } +inSeptConfigSnmpStatue OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable or disable SNMP access" + ::= { inSeptConfigSnmp 1} + +inSeptConfigSnmpPortNumber OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setting the server port of SNMP." + ::= { inSeptConfigSnmp 2} + +inSeptConfigControl OBJECT IDENTIFIER ::= { inSeptConfig 11 } +inSeptConfigResetToDefault OBJECT-TYPE + SYNTAX INTEGER { + reset(1), + nothing(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Reset all parameters of interSeptor to default value" + ::= { inSeptConfigControl 1} + +inSeptConfigRestart OBJECT-TYPE + SYNTAX INTEGER { + restart(1), + nothing(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Restart interSeptor" + ::= { inSeptConfigControl 2} + +inSeptConfigTrap OBJECT IDENTIFIER ::= { inSeptConfig 12 } +inSeptConfigTrapRetryCount OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The count of repeat traps to send to NMS before trap + acknowledgement is received." + ::= { inSeptConfigTrap 1} + +inSeptConfigTrapRetryTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The time between retrying to send traps to NMS." + ::= { inSeptConfigTrap 2} + +inSeptConfigTrapAckSignature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The signature of trap acknowledgement." + ::= { inSeptConfigTrap 3} + + +inSeptConfigPollRate OBJECT-TYPE + SYNTAX INTEGER (3..60) + ACCESS read-write + STATUS mandatory + DESCRIPTION + " The frequency that interSeptor updates readings from sensors + (unit : second)." + ::= { inSeptConfig 13} + +inSeptConfigTrapsReceiversTable OBJECT-TYPE + SYNTAX SEQUENCE OF InSeptConfigTrapsReceiversEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of managers to send traps to. The number of + entries is given by the value of inSeptConfigNumTrapReceivers" + ::= { inSeptConfig 14} + +inSeptConfigTrapsReceiversEntry OBJECT-TYPE + SYNTAX InSeptConfigTrapsReceiversEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The managers to send traps to." + INDEX { inSepttrapsIndex} + ::= { inSeptConfigTrapsReceiversTable 1 } + +InSeptConfigTrapsReceiversEntry ::= + SEQUENCE { + inSepttrapsIndex + INTEGER, + inSepttrapsReceiverAddr + IpAddress, + inSeptreceiverCommunityString + DisplayString, + inSeptreceiverSeverityLevel + INTEGER, + inSeptreceiverDescription + DisplayString + } + +inSepttrapsIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to a trap receiver entry." + ::= { inSeptConfigTrapsReceiversEntry 1 } + +inSepttrapsReceiverAddr OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The IP address of the manager to send a trap to." + ::= { inSeptConfigTrapsReceiversEntry 2 } + +inSeptreceiverCommunityString OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..19)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The community name to use in the trap when + sent to the manager." + ::= { inSeptConfigTrapsReceiversEntry 3 } + +inSeptreceiverSeverityLevel OBJECT-TYPE + SYNTAX INTEGER { + informational(1), + warning(2), + severe(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The severity level of traps to be received by this manager." + ::= { inSeptConfigTrapsReceiversEntry 4 } + +inSeptreceiverDescription OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..31)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Description of trap receivers" + ::= { inSeptConfigTrapsReceiversEntry 5 } + +inSeptConfigAccessControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF InSeptConfigAccessControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of managers which can access interSeptor with private + community string." + ::= { inSeptConfig 15} + +inSeptConfigAccessControlEntry OBJECT-TYPE + SYNTAX InSeptConfigAccessControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The managers." + INDEX { accessIndex} + ::= { inSeptConfigAccessControlTable 1 } + +InSeptConfigAccessControlEntry ::= + SEQUENCE { + accessIndex + INTEGER, + accessControlAddr + IpAddress, + accessCommunityString + DisplayString, + accessControlMode + INTEGER + } + +accessIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to a access control entry." + ::= { inSeptConfigAccessControlEntry 1 } + +accessControlAddr OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The IP address of the manager to access interSeptor" + ::= { inSeptConfigAccessControlEntry 2 } + +accessCommunityString OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..19)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The community name to use in the manager when + access interSeptor" + ::= { inSeptConfigAccessControlEntry 3 } + +accessControlMode OBJECT-TYPE + SYNTAX INTEGER { + readOnly (1), + read-write (2), + notAccess (3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Access type, only read/Write access type can change parameter + of interSeptor" + ::= { inSeptConfigAccessControlEntry 4 } + + +inSeptConfigTemperatureUnit OBJECT-TYPE + SYNTAX INTEGER { + celsius(1), + fahrenheit(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The temperature unit of the system, can be Celsius or Farenheit" + ::= { inSeptConfig 16} + +inSeptConfigDateFormat OBJECT-TYPE + SYNTAX INTEGER { + dd-mm-yyyy(1), + mm-dd-yyyy(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The date format of the system, can be dd/mm/yyyy or mm/dd/yyyy" + ::= { inSeptConfig 17} + + +-- Sensor Monitoring + +inSeptsensorMonitorSensorNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of sensors that can be monitored." + ::= { inSeptsensorMonitor 1} + +inSeptsensorMonitorSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF SensorMonitorSensorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of sensor devices to be monitored." + ::= { inSeptsensorMonitor 2} + +inSeptsensorMonitorSensorEntry OBJECT-TYPE + SYNTAX SensorMonitorSensorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The sensor device." + INDEX { inSeptsensorMonitorDeviceIndex} + ::= { inSeptsensorMonitorSensorTable 1 } + +SensorMonitorSensorEntry ::= + SEQUENCE { + inSeptsensorMonitorDeviceIndex + INTEGER, + inSeptsensorMonitorDeviceStatus + INTEGER, + inSeptsensorMonitorDeviceTemperature + INTEGER, + inSeptsensorMonitorDeviceTemperatureAlarm + INTEGER, + inSeptsensorMonitorDeviceHumidity + INTEGER, + inSeptsensorMonitorDeviceHumidityAlarm + INTEGER, + inSeptsensorMonitorAlarm1 + INTEGER, + inSeptsensorMonitorAlarm2 + INTEGER + } + +inSeptsensorMonitorDeviceIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to a sensor device entry." + ::= { inSeptsensorMonitorSensorEntry 1 } + +inSeptsensorMonitorDeviceStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + disabled(2), + eMD-HT(3), + eMD-T(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The device type connected to interSeptor." + ::= { inSeptsensorMonitorSensorEntry 2 } + +inSeptsensorMonitorDeviceTemperature OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The temperature of sensor on device interSeptor, the unit is 0.1 degree." + ::= { inSeptsensorMonitorSensorEntry 3 } + +inSeptsensorMonitorDeviceTemperatureAlarm OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + disabled(2), + normal(3), + lowWarning(4), + lowCritical(5), + highWarning(6), + highCritical(7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The alarm type of sensor on device interSeptor." + ::= { inSeptsensorMonitorSensorEntry 4 } + +inSeptsensorMonitorDeviceHumidity OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The humidity of sensor on device interSeptor, the unit is 0.1%." + ::= { inSeptsensorMonitorSensorEntry 5 } + +inSeptsensorMonitorDeviceHumidityAlarm OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + disabled(2), + normal(3), + lowWarning(4), + lowCritical(5), + highWarning(6), + highCritical(7) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The alarm type of sensor on device interSeptor." + ::= { inSeptsensorMonitorSensorEntry 6 } + +inSeptsensorMonitorAlarm1 OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + disabled(2), + active(3), + inactive(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The device status of sensor 1 connected to interSeptor." + ::= { inSeptsensorMonitorSensorEntry 7 } + +inSeptsensorMonitorAlarm2 OBJECT-TYPE + SYNTAX INTEGER { + unknown(1), + disabled(2), + active(3), + inactive(4) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The device status of sensor 2 connected to interSeptor." + ::= { inSeptsensorMonitorSensorEntry 8 } + +-- Sensor Configuration + +inSeptsensorConfigSensorNumber OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of sensors that are connected to interSeptor." + ::= { inSeptsensorConfig 1 } + +inSeptsensorConfigSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF InSeptsensorConfigSensorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of sensor devices to be configured." + ::= { inSeptsensorConfig 2 } + +inSeptsensorConfigSensorEntry OBJECT-TYPE + SYNTAX InSeptsensorConfigSensorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The sensor device." + INDEX { inSeptsensorConfigDeviceIndex } + ::= { inSeptsensorConfigSensorTable 1 } + +InSeptsensorConfigSensorEntry ::= + SEQUENCE { + inSeptsensorConfigDeviceIndex + INTEGER, + inSeptsensorConfigDeviceName + DisplayString, + inSeptsensorConfigDeviceState + INTEGER + } + +inSeptsensorConfigDeviceIndex OBJECT-TYPE + SYNTAX INTEGER (1..2147483647) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index to a sensor device entry." + ::= { inSeptsensorConfigSensorEntry 1 } + +inSeptsensorConfigDeviceName OBJECT-TYPE + SYNTAX DisplayString (SIZE(0..15)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of the sensor device for identification." + ::= { inSeptsensorConfigSensorEntry 2 } + +inSeptsensorConfigDeviceState OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + auto(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The setup of sensor device type." + ::= { inSeptsensorConfigSensorEntry 3 } + +inSeptsensorConfigSensor1 OBJECT IDENTIFIER ::= { inSeptsensorConfig 3 } + +inSeptsensorConfigSensor1DeviceName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of sensor device." + ::= { inSeptsensorConfigSensor1 1} + +inSeptsensorConfigSensor1DeviceState OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + auto(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The setup of sensor device type." + ::= { inSeptsensorConfigSensor1 2 } + +inSeptsensorConfigSensor1Temperature OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor1 3 } + +inSeptsensorConfigSensor1TemperatureName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The temperature sensor name." + ::= { inSeptsensorConfigSensor1Temperature 1 } + +inSeptsensorConfigSensor1TemperatureLowWarning OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set point to trigger low warning alarm." + ::= { inSeptsensorConfigSensor1Temperature 2 } + + +inSeptsensorConfigSensor1TemperatureLowCritical OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The threshold to trigger low critical alarm." + ::= { inSeptsensorConfigSensor1Temperature 3 } + +inSeptsensorConfigSensor1TemperatureHighWarning OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The threshold to trigger high warning alarm." + ::= { inSeptsensorConfigSensor1Temperature 4 } + +inSeptsensorConfigSensor1TemperatureHighCritical OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The threshold to trigger high critical alarm." + ::= { inSeptsensorConfigSensor1Temperature 5 } + +inSeptsensorConfigSensor1TemperatureHysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set value to prevent too many alarms when temperature is hovering around the + set threshold." + ::= { inSeptsensorConfigSensor1Temperature 6 } + +inSeptsensorConfigSensor1TemperatureCalibration OBJECT-TYPE + SYNTAX INTEGER { + temperatureIncrease0Point0(1), + temperatureIncrease0Point5(2), + temperatureIncrease1Point0(3), + temperatureIncrease1Point5(4), + temperatureIncrease2Point0(5), + temperatureIncrease2Point5(6), + temperatureIncrease3Point0(7), + temperatureMinus0Point5(8), + temperatureMinus1Point0(9), + temperatureMinus1Point5(10), + temperatureMinus2Point0(11), + temperatureMinus2Point5(12), + temperatureMinusPoint0(13) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set value to get the correct temperature according to your reference temperature." + ::= { inSeptsensorConfigSensor1Temperature 7 } + +inSeptsensorConfigSensor1TemperatureLowWarningStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger low warning alarm." + ::= { inSeptsensorConfigSensor1Temperature 8 } + +inSeptsensorConfigSensor1TemperatureLowCriticalStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger low critical alarm." + ::= { inSeptsensorConfigSensor1Temperature 9 } + +inSeptsensorConfigSensor1TemperatureHighWarningStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger high warning alarm." + ::= { inSeptsensorConfigSensor1Temperature 10 } + +inSeptsensorConfigSensor1TemperatureHighCriticalStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger high critical alarm." + ::= { inSeptsensorConfigSensor1Temperature 11 } + +inSeptsensorConfigSensor1Humidity OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor1 4 } + +inSeptsensorConfigSensor1HumdityName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The humidity sensor name." + ::= { inSeptsensorConfigSensor1Humidity 1 } + +inSeptsensorConfigSensor1HumidityLowWarning OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set point to trigger low warning alarm." + ::= { inSeptsensorConfigSensor1Humidity 2 } + + +inSeptsensorConfigSensor1HumidityLowCritical OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The threshole to trigger low critical alarm." + ::= { inSeptsensorConfigSensor1Humidity 3 } + +inSeptsensorConfigSensor1HumidityHighWarning OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The threshold to trigger high warning alarm." + ::= { inSeptsensorConfigSensor1Humidity 4 } + +inSeptsensorConfigSensor1HumidityHighCritical OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The threshold to trigger high critical alarm." + ::= { inSeptsensorConfigSensor1Humidity 5 } + +inSeptsensorConfigSensor1HumidityHysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set value to prevent too many alarms when Humidity is hovering around the + set threshold." + ::= { inSeptsensorConfigSensor1Humidity 6 } + +inSeptsensorConfigSensor1HumidityCalibration OBJECT-TYPE + SYNTAX INTEGER { + humidityIncrease0Point0(1), + humidityIncrease1Point0(2), + humidityIncrease2Point0(3), + humidityIncrease3Point0(4), + humidityIncrease4Point0(5), + humidityIncrease5Point0(6), + humidityIncrease6Point0(7), + humidityMinus1Point0(8), + humidityMinus2Point0(9), + humidityMinus3Point0(10), + humidityMinus4Point0(11), + humidityMinus5Point0(12), + humidityMinus6Point0(13) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set value to get the correct temperature according to your reference temperature." + ::= { inSeptsensorConfigSensor1Humidity 7 } + +inSeptsensorConfigSensor1HumidityLowWarningStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger low warning alarm." + ::= { inSeptsensorConfigSensor1Humidity 8 } + +inSeptsensorConfigSensor1HumidityLowCriticalStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger low critical alarm." + ::= { inSeptsensorConfigSensor1Humidity 9 } + +inSeptsensorConfigSensor1HumidityHighWarningStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger high warning alarm." + ::= { inSeptsensorConfigSensor1Humidity 10 } + +inSeptsensorConfigSensor1HumidityHighCriticalStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger high critical alarm." + ::= { inSeptsensorConfigSensor1Humidity 11 } + +inSeptsensorConfigSensor1Alarm1 OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor1 5 } + +inSeptsensorConfigSensor1Alarm1Name OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of alarm-1." + ::= { inSeptsensorConfigSensor1Alarm1 1 } + +inSeptsensorConfigSensor1Alarm1State OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + normalOpen(2), + normalClose(3), + highActive(4), + lowActive(5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setup the signal type to trigger alarm." + ::= { inSeptsensorConfigSensor1Alarm1 2 } + +inSeptsensorConfigSensor1Alarm1Hysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set value to delay the alarm triggered when event occurs." + ::= { inSeptsensorConfigSensor1Alarm1 3 } + +inSeptsensorConfigSensor1Alarm2 OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor1 6 } + +inSeptsensorConfigSensor1Alarm2Name OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of alarm-1." + ::= { inSeptsensorConfigSensor1Alarm2 1 } + +inSeptsensorConfigSensor1Alarm2State OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + normalOpen(2), + normalClose(3), + highActive(4), + lowActive(5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setup the signal type to trigger alarm." + ::= { inSeptsensorConfigSensor1Alarm2 2 } + +inSeptsensorConfigSensor1Alarm2Hysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set value to delay the alarm triggered when event occurs." + ::= { inSeptsensorConfigSensor1Alarm2 3 } + +inSeptsensorConfigSensor2 OBJECT IDENTIFIER ::= { inSeptsensorConfig 4 } + +inSeptsensorConfigSensor2DeviceName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of sensor device." + ::= { inSeptsensorConfigSensor2 1} + +inSeptsensorConfigSensor2DeviceState OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + auto(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The setup of sensor device type." + ::= { inSeptsensorConfigSensor2 2 } + +inSeptsensorConfigSensor2Temperature OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor2 3 } + +inSeptsensorConfigSensor2TemperatureName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The temperature sensor name." + ::= { inSeptsensorConfigSensor2Temperature 1 } + +inSeptsensorConfigSensor2TemperatureLowWarning OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set point to trigger low warning alarm." + ::= { inSeptsensorConfigSensor2Temperature 2 } + + +inSeptsensorConfigSensor2TemperatureLowCritical OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The threshold to trigger low critical alarm." + ::= { inSeptsensorConfigSensor2Temperature 3 } + +inSeptsensorConfigSensor2TemperatureHighWarning OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The threshold to trigger high warning alarm." + ::= { inSeptsensorConfigSensor2Temperature 4 } + +inSeptsensorConfigSensor2TemperatureHighCritical OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The threshold to trigger high critical alarm." + ::= { inSeptsensorConfigSensor2Temperature 5 } + +inSeptsensorConfigSensor2TemperatureHysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set value to prevent too many alarms when temperature is hovering around the + set threshold." + ::= { inSeptsensorConfigSensor2Temperature 6 } + +inSeptsensorConfigSensor2TemperatureCalibration OBJECT-TYPE + SYNTAX INTEGER { + temperatureIncrease0Point0(1), + temperatureIncrease0Point5(2), + temperatureIncrease1Point0(3), + temperatureIncrease1Point5(4), + temperatureIncrease2Point0(5), + temperatureIncrease2Point5(6), + temperatureIncrease3Point0(7), + temperatureMinus0Point5(8), + temperatureMinus1Point0(9), + temperatureMinus1Point5(10), + temperatureMinus2Point0(11), + temperatureMinus2Point5(12), + temperatureMinusPoint0(13) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set value to get the correct temperature according to your reference temperature." + ::= { inSeptsensorConfigSensor2Temperature 7 } + +inSeptsensorConfigSensor2TemperatureLowWarningStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger low warning alarm." + ::= { inSeptsensorConfigSensor2Temperature 8 } + +inSeptsensorConfigSensor2TemperatureLowCriticalStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger low critical alarm." + ::= { inSeptsensorConfigSensor2Temperature 9 } + +inSeptsensorConfigSensor2TemperatureHighWarningStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger high warning alarm." + ::= { inSeptsensorConfigSensor2Temperature 10 } + +inSeptsensorConfigSensor2TemperatureHighCriticalStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger high critical alarm." + ::= { inSeptsensorConfigSensor2Temperature 11 } + +inSeptsensorConfigSensor2Humidity OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor2 4 } + +inSeptsensorConfigSensor2HumdityName OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The humidity sensor name." + ::= { inSeptsensorConfigSensor2Humidity 1 } + +inSeptsensorConfigSensor2HumidityLowWarning OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set point to trigger low warning alarm." + ::= { inSeptsensorConfigSensor2Humidity 2 } + + +inSeptsensorConfigSensor2HumidityLowCritical OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The threshold to trigger low critical alarm." + ::= { inSeptsensorConfigSensor2Humidity 3 } + +inSeptsensorConfigSensor2HumidityHighWarning OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The threshold to trigger high warning alarm." + ::= { inSeptsensorConfigSensor2Humidity 4 } + +inSeptsensorConfigSensor2HumidityHighCritical OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The threshold to trigger high critical alarm." + ::= { inSeptsensorConfigSensor2Humidity 5 } + +inSeptsensorConfigSensor2HumidityHysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set value to prevent too many alarms when Humidity is hovering around the + set threshold." + ::= { inSeptsensorConfigSensor2Humidity 6 } + +inSeptsensorConfigSensor2HumidityCalibration OBJECT-TYPE + SYNTAX INTEGER { + humidityIncrease0Point0(1), + humidityIncrease1Point0(2), + humidityIncrease2Point0(3), + humidityIncrease3Point0(4), + humidityIncrease4Point0(5), + humidityIncrease5Point0(6), + humidityIncrease6Point0(7), + humidityMinus1Point0(8), + humidityMinus2Point0(9), + humidityMinus3Point0(10), + humidityMinus4Point0(11), + humidityMinus5Point0(12), + humidityMinus6Point0(13) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set value to get the correct temperature according to your reference temperature." + ::= { inSeptsensorConfigSensor2Humidity 7 } + +inSeptsensorConfigSensor2HumidityLowWarningStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger low warning alarm." + ::= { inSeptsensorConfigSensor2Humidity 8 } + +inSeptsensorConfigSensor2HumidityLowCriticalStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger low critical alarm." + ::= { inSeptsensorConfigSensor2Humidity 9 } + +inSeptsensorConfigSensor2HumidityHighWarningStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger high warning alarm." + ::= { inSeptsensorConfigSensor2Humidity 10 } + +inSeptsensorConfigSensor2HumidityHighCriticalStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Enable/disable the set point to trigger high critical alarm." + ::= { inSeptsensorConfigSensor2Humidity 11 } + +inSeptsensorConfigSensor2Alarm1 OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor2 5 } + +inSeptsensorConfigSensor2Alarm1Name OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of alarm-1." + ::= { inSeptsensorConfigSensor2Alarm1 1 } + +inSeptsensorConfigSensor2Alarm1State OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + normalOpen(2), + normalClose(3), + highActive(4), + lowActive(5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setup the signal type to trigger alarm." + ::= { inSeptsensorConfigSensor2Alarm1 2 } + +inSeptsensorConfigSensor2Alarm1Hysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set value to delay the alarm triggered when event occurs." + ::= { inSeptsensorConfigSensor2Alarm1 3 } + +inSeptsensorConfigSensor2Alarm2 OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor2 6 } + +inSeptsensorConfigSensor2Alarm2Name OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..15)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The name of alarm-1." + ::= { inSeptsensorConfigSensor2Alarm2 1 } + +inSeptsensorConfigSensor2Alarm2State OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + normalOpen(2), + normalClose(3), + highActive(4), + lowActive(5) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Setup the signal type to trigger alarm." + ::= { inSeptsensorConfigSensor2Alarm2 2 } + +inSeptsensorConfigSensor2Alarm2Hysteresis OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The set value to delay the alarm triggered when event occurs." + ::= { inSeptsensorConfigSensor2Alarm2 3 } + + +-- =========================================================================== +-- inSeptTraps +-- +-- Traps group +-- =========================================================================== +-- This section defines the well-known notifications sent by +-- inSept agents. +-- Care must be taken to ensure that no particular notification +-- is sent to a single receiving entity more often than once +-- every five seconds. + +inSeptCommunicationRestored TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "INFORMATION: Communication between interSeptor and sensor has been + established." + ::= 1 + +inSeptCommunicationLost TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "WARNING: Communication between interSeptor and sensor has been + lost." + ::= 2 + +inSeptAlarm1Inactive TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "INFORMATION: Alarm1 of sensor has returned from active state." + ::= 3 + +inSeptAlarm1Active TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "WARNING: Alarm1 has become active." + ::= 4 + +inSeptAlarm2Inactive TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "INFORMATION: Alarm2 of sensor has returned from active state." + ::= 5 + +inSeptAlarm2Active TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "WARNING: Alarm2 has become active." + ::= 6 + +inSeptTemperatureNotHighWarning TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "INFORMATION: The temperature of sensor has returned from High warning to normal." + ::= 7 + +inSeptTemperatureHighWarning TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "WARNING: The temperature of sensor is higher than High warning set point." + ::= 8 + +inSeptTemperatureNotLowWarning TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "INFORMATION: The temperature of sensor has returned from low warning to normal." + ::= 9 + +inSeptTemperatureLowWarning TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "WARNING: The temperature of sensor is lower than low warning set point." + ::= 10 + +inSeptTemperatureNotHighCritical TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "INFORMATION: The temperature of sensor is lower than high critical set point." + ::= 11 + +inSeptTemperatureHighCritical TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "CRITICAL: The temperature of sensor is higher than high critical set point." + ::= 12 + +inSeptTemperatureNotLowCritical TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "INFORMATION: The temperature of sensor is higher than low critical set point." + ::= 13 + +inSeptTemperatureLowCritical TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "CRITICAL: The temperature of sensor is lower than low critical set point." + ::= 14 + +inSeptHumidityNotHighWarning TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "INFORMATION: The humidity of sensor has returned from High warning to normal." + ::= 15 + +inSeptHumidityHighWarning TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "WARNING: The humidity of sensor is higher than High warning set point." + ::= 16 + +inSeptHumidityNotLowWarning TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "INFORMATION: The humidity of sensor has returned from low warning to normal." + ::= 17 + +inSeptHumidityLowWarning TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "WARNING: The humidity of sensor is lower than low warning set point." + ::= 18 + +inSeptHumidityNotHighCritical TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "INFORMATION: The humidity of sensor is lower than high critical set point." + ::= 19 + +inSeptHumidityHighCritical TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "CRITICAL: The humidity of sensor is higher than high critical set point." + ::= 20 + +inSeptHumidityNotLowCritical TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "INFORMATION: The humidity of sensor is higher than low critical set point." + ::= 21 + +inSeptHumidityLowCritical TRAP-TYPE + ENTERPRISE inSeptTraps + DESCRIPTION + "CRITICAL: The humidity of sensor is lower than low critical set point." + ::= 22 + +END + |