+-- Juniper Enterprise Specific MIB: Alarm MIB
+--
+-- Copyright (c) 2001-2003, Juniper Networks, Inc.
+-- All rights reserved.
+--
+-- The contents of this document are subject to change without notice.
+--
+
+JUNIPER-ALARM-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, Gauge32
+ FROM SNMPv2-SMI
+ TimeStamp
+ FROM SNMPv2-TC
+ jnxMibs
+ FROM JUNIPER-SMI;
+
+jnxAlarms MODULE-IDENTITY
+ LAST-UPDATED "200307182153Z" -- Fri Jul 18 21:53:46 2003 UTC
+ ORGANIZATION "Juniper Networks, Inc."
+ CONTACT-INFO
+ " Juniper Technical Assistance Center
+ Juniper Networks, Inc.
+ 1133 Innovation Way
+ Sunnyvale, CA 94089
+ E-mail: support@juniper.net"
+
+ DESCRIPTION
+ "This is Juniper Networks' implementation of enterprise
+ specific MIB for alarms from the router chassis box."
+ ::= { jnxMibs 4 }
+
+
+
+
+-- ::= { jnxAlarms 1 } This OID is obsolete.
+
+
+--
+-- Craft Alarms
+--
+
+ jnxCraftAlarms OBJECT IDENTIFIER ::= { jnxAlarms 2 }
+
+
+ jnxAlarmRelayMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- other or unknown
+ passOn(2), -- alarms being passed on
+ cutOff(3) -- alarms being cut off
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarm relay mode of the craft interface
+ panel for both yellow and red alarms.
+
+ Both yellow and red alarms could be cut off
+ by a front panel Alarm Cutoff / Lamp Test
+ (ACO/LT) button.
+
+ In the pass-on mode, the alarm relay will be
+ activated to pass on the yellow or red alarms.
+ In the cut-off mode, both yellow and red alarms
+ will be cut off from the alarm relays which are
+ normally connected to audible sirens or visual
+ flashing devices."
+
+
+ ::= { jnxCraftAlarms 1 }
+
+
+ jnxYellowAlarms OBJECT IDENTIFIER ::= { jnxCraftAlarms 2 }
+
+ jnxYellowAlarmState OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- alarm state is unknown
+ off(2), -- alarm is off
+ on(3) -- alarm is on
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The yellow alarm state on the craft interface
+ panel.
+
+ The yellow alarm is on when there is some
+ system warning such as maintenance alert or
+ significant temperature increase.
+
+ This yellow alarm state could be turned off
+ by the ACO/LT (Alarm Cut Off / Lamp Test) button
+ on the front panel module."
+
+
+ ::= { jnxYellowAlarms 1 }
+
+ jnxYellowAlarmCount OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of currently active and non-silent
+ yellow alarms.
+
+ This object is independent of the ACO/LT (Alarm
+ Cut Off / Lamp Test) button."
+
+
+ ::= { jnxYellowAlarms 2 }
+
+
+ jnxYellowAlarmLastChange OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when the yellow alarm
+ last changed - either from off to on or vice
+ versa. Zero if unknown or never changed since
+ the agent was up."
+
+
+ ::= { jnxYellowAlarms 3 }
+
+
+ jnxRedAlarms OBJECT IDENTIFIER ::= { jnxCraftAlarms 3 }
+
+ jnxRedAlarmState OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- alarm state is unknown
+ off(2), -- alarm is off
+ on(3) -- alarm is on
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The red alarm indication on the craft interface
+ panel.
+
+ The red alarm is on when there is some system
+ failure or power supply failure or the system
+ is experiencing a hardware malfunction or some
+ threshold is being exceeded.
+
+ This red alarm state could be turned off by the
+ ACO/LT (Alarm Cut Off / Lamp Test) button on the
+ front panel module."
+
+
+ ::= { jnxRedAlarms 1 }
+
+
+ jnxRedAlarmCount OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of currently active and non-silent
+ red alarms.
+
+ This object is independent of the ACO/LT (Alarm
+ Cut Off / Lamp Test) button."
+
+
+ ::= { jnxRedAlarms 2 }
+
+
+ jnxRedAlarmLastChange OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when the red alarm
+ last changed - either from off to on or vice
+ versa. Zero if unknown or never changed since
+ the agent was up."
+
+
+ ::= { jnxRedAlarms 3 }
+
+
+END