summaryrefslogtreecommitdiff
path: root/MIBS/junose/Juniper-REDUNDANCY-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/junose/Juniper-REDUNDANCY-MIB')
-rw-r--r--MIBS/junose/Juniper-REDUNDANCY-MIB570
1 files changed, 570 insertions, 0 deletions
diff --git a/MIBS/junose/Juniper-REDUNDANCY-MIB b/MIBS/junose/Juniper-REDUNDANCY-MIB
new file mode 100644
index 0000000..4a27b17
--- /dev/null
+++ b/MIBS/junose/Juniper-REDUNDANCY-MIB
@@ -0,0 +1,570 @@
+
+-- *****************************************************************************
+-- Juniper-REDUNDANCY-MIB
+--
+-- Juniper Networks Enterprise MIB
+-- REDUNDANCY MIB
+--
+-- Copyright (c) 2003 Juniper Networks Inc.
+-- All Rights Reserved.
+-- *****************************************************************************
+
+Juniper-REDUNDANCY-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, Integer32, TimeTicks
+ FROM SNMPv2-SMI
+ DisplayString, RowStatus, TruthValue, TEXTUAL-CONVENTION, DateAndTime
+ FROM SNMPv2-TC
+ sysUpTime
+ FROM SNMPv2-MIB
+ MODULE-COMPLIANCE, OBJECT-GROUP
+ FROM SNMPv2-CONF
+ juniMibs
+ FROM Juniper-MIBs;
+
+juniRedundancyMIB MODULE-IDENTITY
+ LAST-UPDATED "200312122104Z" -- 12-Dec-03 04:04 PM EST
+ ORGANIZATION "Juniper Networks, Inc."
+ CONTACT-INFO
+ " Juniper Networks, Inc.
+ Postal: 10 Technology Park Road
+ Westford, MA 01886-3146
+ USA
+ Tel: +1 978 589 5800
+ E-mail: mib@Juniper.net"
+ DESCRIPTION
+ "The redundancy configuration MIB for Juniper Networks enterprise."
+ -- Revision History
+ REVISION "200312120000Z" -- 12-Dec-03 - JUNOSe 6.0
+ DESCRIPTION
+ "Initial version of this MIB module."
+ ::= { juniMibs 74 }
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Textual conventions
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+JuniRedundancyState ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The current state of redundancy subsystem:
+ notKnown - Redundancy state is unknown.
+ fileSystemSyncing - Redundancy operation is based on file system
+ synchronization. SRP switchover stops forwarding.
+ disabled - Redundancy operation is based on high availability
+ model but high availability is not yet operational.
+ SRP switchover stops forwarding.
+ initializing - Redundancy operation is based on high availability
+ model and standby SRP is being bulk synchronized from
+ active SRP. SRP switchover stops forwarding.
+ pending - Redundancy operation is based on high availability
+ model and bulk synchronization of standby SRP completed.
+ SRP switchover stops forwarding.
+ active - Redundancy operation is based on high availability model
+ and high availability is fully operational. SRP
+ switchover does not stop forwarding."
+ SYNTAX INTEGER {
+ notKnown(1),
+ fileSystemSyncing(2),
+ disabled(3),
+ initializing(4),
+ pending(5),
+ active(6) }
+
+JuniRedundancyMode ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The mode of the redundancy subsystem:
+ fileSystemSynchronization - SRP synchronization is based on file synchronization.
+ highAvailability - SRP synchronization is based on high availability
+ model that allows non-stop forwarding."
+ SYNTAX INTEGER {
+ fileSystemSynchronization(1),
+ highAvailability(2) }
+
+JuniRedundancyResetReason ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Reason codes for the reset of active SRP or a line card that might result
+ in switch of control to standby SRP or spare line card.
+ none - No reset or switchover has occurred and indicates 'power-on'
+ situation.
+ notKnown - Reason is unknown.
+ userInitiated - A safe, manual reset was initiated by the user."
+ SYNTAX INTEGER {
+ none(1),
+ notKnown(2),
+ userInitiated(3) }
+
+JuniRedundancySystemActivationType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Various kinds of system activation:
+ reload - System has reloaded, i.e., no switchover has occurred.
+ coldSwitch - System switched over from active to standby SRP and the
+ switchover involved reloading of line cards interrupting
+ forwarding.
+ warmSwitch - System switched over from active to standby SRP; line cards were
+ not reloaded during switchover and forwarding was uninterrupted."
+ SYNTAX INTEGER {
+ reload(1),
+ coldSwitch(2),
+ warmSwitch(3) }
+
+JuniRedundancyResetType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Identifies the nature of the reset and slot types involved since the
+ system is powered on.
+ notKnown - Reset type is unknown.
+ srpReload - The reset involved reloading SRP slot(s).
+ srpSwitchover - The reset involved switchover of SRP slot(s).
+ linecardReload - The reset involved reloading the line card slot(s).
+ linecardSwitchover - The reset involved line card redundancy."
+ SYNTAX INTEGER {
+ notKnown(1),
+ srpReload(2),
+ srpSwitchover(3),
+ linecardReload(4),
+ linecardSwitchover(5) }
+
+JuniRedundancyHistoryCommand ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Identifies the command to be performed on the system activation
+ history table.
+ keep - Retain history in persistent storage.
+ clear - Erase the current entries of juniRedundancySystemActivationHistoryTable."
+ SYNTAX INTEGER {
+ keep(1),
+ clear(2) }
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- MIB Structure
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniRedundancyNotifications OBJECT IDENTIFIER ::= { juniRedundancyMIB 0 }
+juniRedundancyObjects OBJECT IDENTIFIER ::= { juniRedundancyMIB 1 }
+juniRedundancyMIBConformance OBJECT IDENTIFIER ::= { juniRedundancyMIB 2 }
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Managed object groups
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniRedundancyStatus OBJECT IDENTIFIER ::= {juniRedundancyObjects 1 }
+juniRedundancyCfg OBJECT IDENTIFIER ::= {juniRedundancyObjects 2 }
+juniRedundancyHistory OBJECT IDENTIFIER ::= {juniRedundancyObjects 3 }
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Managed objects for Redundancy
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+--
+-- Status sub group definitions
+--
+juniRedundancyActiveSlot OBJECT-TYPE
+ SYNTAX Integer32(0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique identifier for active SRP slot."
+ ::= { juniRedundancyStatus 1 }
+
+juniRedundancyActiveSlotState OBJECT-TYPE
+ SYNTAX JuniRedundancyState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of redundancy on active SRP."
+ ::= { juniRedundancyStatus 2 }
+
+juniRedundancyStandbySlot OBJECT-TYPE
+ SYNTAX Integer32(0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique identifier for standby SRP slot."
+ ::= { juniRedundancyStatus 3 }
+
+juniRedundancyStandbySlotState OBJECT-TYPE
+ SYNTAX JuniRedundancyState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of redundancy on standby SRP."
+ ::= { juniRedundancyStatus 4 }
+
+juniRedundancyLastResetReason OBJECT-TYPE
+ SYNTAX JuniRedundancyResetReason
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The reason for the last SRP reset."
+ ::= { juniRedundancyStatus 5 }
+
+juniRedundancyLastSystemActivationTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUptime when the system is operational either
+ following a reload or a switchover. The value 0 is a special
+ value to indicate 'from reset'."
+ ::= { juniRedundancyStatus 6 }
+
+juniRedundancyLastSystemActivationType OBJECT-TYPE
+ SYNTAX JuniRedundancySystemActivationType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of last SRP activation when the system became operational."
+ ::= { juniRedundancyStatus 7 }
+
+juniRedundancyHaActiveTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUptime when active SRP enters 'active' state as
+ indicated in juniRedundancyActiveSlotState object. The value is 0 in
+ file system synchronization redundancy mode."
+ ::= { juniRedundancyStatus 8 }
+
+--
+-- Cfg sub group definitions
+--
+juniRedundancyNotifsEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Allows enabling and disabling of redundancy subsystem notifications."
+ DEFVAL { true }
+ ::= { juniRedundancyCfg 1 }
+
+juniRedundancyCfgRedundancyMode OBJECT-TYPE
+ SYNTAX JuniRedundancyMode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates the redundancy mode configured on the system."
+ DEFVAL { fileSystemSynchronization }
+ ::= { juniRedundancyCfg 2 }
+
+--
+-- History sub group definitions
+--
+juniRedundancySystemActivationHistoryTableMaxLength OBJECT-TYPE
+ SYNTAX Integer32(0..50)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Maximum number of entries allowed in juniRedundancySystemActivationHistoryTable.
+ A value of 0 will result in no history being displayed in
+ juniRedundancySystemActivationHistoryTable."
+ DEFVAL { 0 }
+ ::= { juniRedundancyHistory 1 }
+
+juniRedundancySystemActivationHistoryCommand OBJECT-TYPE
+ SYNTAX JuniRedundancyHistoryCommand
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A control variable to perform certain operations on
+ juniRedundancySystemActivationHistoryTable."
+ DEFVAL { keep }
+ ::= { juniRedundancyHistory 2 }
+
+juniRedundancySystemActivationHistoryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniRedundancySystemActivationHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that tracks the history of all reloads and switchovers that have
+ occurred since system is powered on. The maximum number of entries permissible
+ in this table is defined by juniRedundancySystemActivationHistoryTableMaxLength.
+ When the number of entries in the table reaches the maximum limit, the next
+ entry would replace the oldest existing entry in the table."
+ ::= { juniRedundancyHistory 3 }
+
+juniRedundancySystemActivationHistoryEntry OBJECT-TYPE
+ SYNTAX JuniRedundancySystemActivationHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The entries in this table contain the reload and switchover information.
+ Each entry in the table is indexed by juniRedundancySystemActivationHistoryIndex.
+ The index wraps around to 1 after reaching the maximum value."
+ INDEX { juniRedundancySystemActivationHistoryIndex }
+ ::= { juniRedundancySystemActivationHistoryTable 1 }
+
+JuniRedundancySystemActivationHistoryEntry ::= SEQUENCE {
+ juniRedundancySystemActivationHistoryIndex Integer32,
+ juniRedundancyHistoryResetType JuniRedundancyResetType,
+ juniRedundancyHistoryActivationType JuniRedundancySystemActivationType,
+ juniRedundancyHistoryPrevActiveSlot Integer32,
+ juniRedundancyHistoryPrevActiveRelease DisplayString,
+ juniRedundancyHistoryCurrActiveSlot Integer32,
+ juniRedundancyHistoryCurrActiveRelease DisplayString,
+ juniRedundancyHistoryResetReason JuniRedundancyResetReason,
+ juniRedundancyHistoryActivationTime DateAndTime }
+
+juniRedundancySystemActivationHistoryIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An integer value for the purpose of indexing system
+ activation history table. After reaching maximum value as
+ indicated by juniRedundancySystemActivationHistoryTableMaxLength,
+ it wraps around to 1."
+ ::= { juniRedundancySystemActivationHistoryEntry 1 }
+
+juniRedundancyHistoryResetType OBJECT-TYPE
+ SYNTAX JuniRedundancyResetType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the nature of the reset - reload or switchover - and the slot
+ types involved. Depending on the value of this object, certain elements
+ of JuniRedundancySystemActivationHistoryEntry will not be applicable."
+ ::= { juniRedundancySystemActivationHistoryEntry 2 }
+
+juniRedundancyHistoryActivationType OBJECT-TYPE
+ SYNTAX JuniRedundancySystemActivationType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the activation type of the particular historical system
+ activation entry with respect to the slot types involved."
+ ::= { juniRedundancySystemActivationHistoryEntry 3 }
+
+juniRedundancyHistoryPrevActiveSlot OBJECT-TYPE
+ SYNTAX Integer32(0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the slot number of active SRP or line card that went down."
+ ::= { juniRedundancySystemActivationHistoryEntry 4 }
+
+juniRedundancyHistoryPrevActiveRelease OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the system-wide boot release file name of the slot indicated
+ by juniRedundancyHistoryPrevActiveSlot."
+ ::= { juniRedundancySystemActivationHistoryEntry 5 }
+
+juniRedundancyHistoryCurrActiveSlot OBJECT-TYPE
+ SYNTAX Integer32(0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the slot number of standby SRP or spare line card that took over."
+ ::= { juniRedundancySystemActivationHistoryEntry 6 }
+
+juniRedundancyHistoryCurrActiveRelease OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the system-wide boot release file name of the slot indicated
+ by juniRedundancyHistoryCurrActiveSlot."
+ ::= { juniRedundancySystemActivationHistoryEntry 7 }
+
+juniRedundancyHistoryResetReason OBJECT-TYPE
+ SYNTAX JuniRedundancyResetReason
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the reason for reload or switchover of the slots involved."
+ ::= { juniRedundancySystemActivationHistoryEntry 8 }
+
+juniRedundancyHistoryActivationTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the date and time when the reload or switchover of the slots
+ occurred."
+ ::= { juniRedundancySystemActivationHistoryEntry 9 }
+
+juniRedundancyHistoryReloads OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the number of reloads since the system is powered on."
+ ::= { juniRedundancyHistory 4 }
+
+juniRedundancyHistoryColdSwitchovers OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the number of cold switchovers since the system is powered on."
+ ::= { juniRedundancyHistory 5 }
+
+juniRedundancyHistoryWarmSwitchovers OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Indicates the number of warm switchovers since the system is powered on."
+ ::= { juniRedundancyHistory 6 }
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Notifications
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniRedundancyColdSwitchoverNotification NOTIFICATION-TYPE
+ OBJECTS {
+ juniRedundancyActiveSlot,
+ juniRedundancyLastResetReason
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated in a dual SRP system when control
+ transfers from one to SRP to the other in file system synchronization
+ mode or when high availability is not operational. This notification
+ is sent by the newly active SRP immediately following the switchover
+ in which configuration is preserved but volatile state is lost."
+ ::= { juniRedundancyNotifications 1 }
+
+juniRedundancyWarmSwitchoverNotification NOTIFICATION-TYPE
+ OBJECTS {
+ juniRedundancyActiveSlot,
+ juniRedundancyLastResetReason
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is generated in a dual SRP system when control
+ transfers from one SRP to the other and high availability is
+ operational. This notification is sent by the newly active SRP
+ immediately following the switchover in which configuration and
+ volatile state are preserved."
+ ::= { juniRedundancyNotifications 2 }
+
+juniRedundancyStateEnabledNotification NOTIFICATION-TYPE
+ OBJECTS {
+ juniRedundancyActiveSlot
+ }
+ STATUS current
+ DESCRIPTION
+ "A state change notification sent by active SRP whenever system enters
+ 'active' state."
+ ::= { juniRedundancyNotifications 3 }
+
+juniRedundancyStateDisabledNotification NOTIFICATION-TYPE
+ OBJECTS {
+ juniRedundancyActiveSlot
+ }
+ STATUS current
+ DESCRIPTION
+ "A state change notification sent by active SRP whenever system enters
+ 'disabled' state."
+ ::= { juniRedundancyNotifications 4 }
+
+juniRedundancyStatePendingNotification NOTIFICATION-TYPE
+ OBJECTS {
+ juniRedundancyActiveSlot
+ }
+ STATUS current
+ DESCRIPTION
+ "A state change notification sent by active SRP whenever system enters
+ 'pending' state."
+ ::= { juniRedundancyNotifications 5 }
+
+juniRedundancyModeNotification NOTIFICATION-TYPE
+ OBJECTS {
+ juniRedundancyActiveSlot,
+ juniRedundancyCfgRedundancyMode
+ }
+ STATUS current
+ DESCRIPTION
+ "A mode change notification sent by active SRP whenever redundancy mode
+ of the system is changed from 'fileSystemSynchronization' to 'highAvailability'
+ and vice versa."
+ ::= { juniRedundancyNotifications 6 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Conformance information
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniRedundancyMIBCompliances OBJECT IDENTIFIER ::= { juniRedundancyMIBConformance 1 }
+juniRedundancyMIBGroups OBJECT IDENTIFIER ::= { juniRedundancyMIBConformance 2 }
+
+--
+-- compliance statements
+--
+juniRedundancyMIBCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for system redundancy support."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniRedundancyStatusGroup,
+ juniRedundancyCfgGroup,
+ juniRedundancyHistoryGroup,
+ juniRedundancyNotificationGroup
+ }
+ ::= { juniRedundancyMIBCompliances 1 }
+
+--
+-- units of conformance
+--
+juniRedundancyStatusGroup OBJECT-GROUP
+ OBJECTS {
+ juniRedundancyActiveSlot,
+ juniRedundancyActiveSlotState,
+ juniRedundancyStandbySlot,
+ juniRedundancyStandbySlotState,
+ juniRedundancyLastResetReason,
+ juniRedundancyLastSystemActivationTime,
+ juniRedundancyLastSystemActivationType,
+ juniRedundancyHaActiveTime }
+ STATUS current
+ DESCRIPTION
+ "The collection of redundancy status objects."
+ ::= { juniRedundancyMIBGroups 1 }
+
+juniRedundancyCfgGroup OBJECT-GROUP
+ OBJECTS {
+ juniRedundancyNotifsEnabled,
+ juniRedundancyCfgRedundancyMode }
+ STATUS current
+ DESCRIPTION
+ "The collection of redundancy configuration objects."
+ ::= { juniRedundancyMIBGroups 2 }
+
+juniRedundancyHistoryGroup OBJECT-GROUP
+ OBJECTS {
+ juniRedundancySystemActivationHistoryTableMaxLength,
+ juniRedundancySystemActivationHistoryCommand,
+ juniRedundancyHistoryResetType,
+ juniRedundancyHistoryActivationType,
+ juniRedundancyHistoryPrevActiveSlot,
+ juniRedundancyHistoryPrevActiveRelease,
+ juniRedundancyHistoryCurrActiveSlot,
+ juniRedundancyHistoryCurrActiveRelease,
+ juniRedundancyHistoryResetReason,
+ juniRedundancyHistoryActivationTime,
+ juniRedundancyHistoryReloads,
+ juniRedundancyHistoryColdSwitchovers,
+ juniRedundancyHistoryWarmSwitchovers }
+ STATUS current
+ DESCRIPTION
+ "The collection of redundancy history objects."
+ ::= { juniRedundancyMIBGroups 3 }
+
+juniRedundancyNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ juniRedundancyColdSwitchoverNotification,
+ juniRedundancyWarmSwitchoverNotification,
+ juniRedundancyStateEnabledNotification,
+ juniRedundancyStateDisabledNotification,
+ juniRedundancyStatePendingNotification,
+ juniRedundancyModeNotification }
+ STATUS current
+ DESCRIPTION
+ "The collection of notifications for redundancy events."
+ ::= { juniRedundancyMIBGroups 4 }
+
+END