+-- Juniper-UNI-SONET-MIB
+--
+-- Juniper Networks Enterprise MIB
+-- SONET MIB
+--
+-- Copyright (c) 1998 Redstone Communications, Inc.
+-- Copyright (c) 1999, 2001 Unisphere Networks, Inc.
+-- Copyright (c) 2002, 2003 Juniper Networks, Inc.
+-- All Rights Reserved.
+-- *****************************************************************************
+
+Juniper-UNI-SONET-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32, NOTIFICATION-TYPE
+ FROM SNMPv2-SMI
+ DisplayString, TruthValue, TEXTUAL-CONVENTION, RowStatus
+ FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
+ FROM SNMPv2-CONF
+ ifIndex, InterfaceIndex, InterfaceIndexOrZero, ifAlias
+ FROM IF-MIB
+ JuniNextIfIndex
+ FROM Juniper-TC
+ juniMibs
+ FROM Juniper-MIBs;
+
+juniSonetMIB MODULE-IDENTITY
+ LAST-UPDATED "200307161952Z" -- 16-Jul-03 03:52 PM EDT
+ ORGANIZATION "Juniper Networks, Inc."
+ CONTACT-INFO
+ " Juniper Networks, Inc.
+ Postal: 10 Technology Park Drive
+ Westford, MA 01886-3146
+ USA
+ Tel: +1 978 589 5800
+ Email: mib@Juniper.net"
+ DESCRIPTION
+ "The SONET MIB for the Juniper Networks enterprise. This MIB contains
+ managed objects for SONET interfaces. It contains management objects
+ for configuration of interface attributes that either are absent from,
+ or read-only in the standard SONET-MIB."
+ -- Revision History
+ REVISION "200307161952Z" -- 16-Jul-03 03:52 PM EDT - JUNOSe 5.1
+ DESCRIPTION
+ "Added path event status and notification support.
+ Updated path creation description.
+ Added missing default values."
+ REVISION "200211221637Z" -- 22-Nov-02 11:37 AM EST - JUNOSe 5.0
+ DESCRIPTION
+ "Replaced Unisphere names with Juniper names.
+ Expanded MIB to include following objects:
+ juniSonetMediumTriggerAlarms
+ juniSonetMediumTriggerDelay
+ juniSonetPathTriggerAlarms
+ juniSonetPathTriggerDelay
+ juniSonetPathC2ByteOverrideFlag
+ juniSonetPathC2ByteOverride "
+ REVISION "200110102042Z" -- 10-Oct-01 04:42 PM EDT - JUNOSe 3.2
+ DESCRIPTION
+ "Deprecated juniSonetMediumType, juniSonetMediumCircuitIdentifier and
+ juniSonetVTType."
+ REVISION "200101021800Z" -- 02-Jan-01 01:00 PM EST - JUNOSe 3.0
+ DESCRIPTION
+ "Expanded MIB to include following tables and objects:
+ juniSonetPathCapabilityTable
+ juniSonetPathNextIfIndex
+ juniSonetPathTable
+ juniSonetVTNextIfIndex
+ juniSonetVTTable "
+ REVISION "9811130000Z" -- 13-Nov-98 - JUNOSe 1.0
+ DESCRIPTION
+ "Initial version of this MIB module."
+ ::= { juniMibs 7 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Textual conventions
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+JuniSonetLineSpeed ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The set of SONET Line Speeds."
+ SYNTAX INTEGER {
+ sonetUnknownSpeed(0),
+ sonetOc1Stm0(1),
+ sonetOc3Stm1(2),
+ sonetOc12Stm3(3),
+ sonetOc48Stm16(4) }
+
+JuniSonetLogicalPathChannel ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "A SONET Path channel description that uniquely identifies the SONET
+ Path and is administratively assigned."
+ SYNTAX Integer32 (0..2147483647)
+
+JuniSonetPathHierarchy ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "32a"
+ STATUS current
+ DESCRIPTION
+ "Represents textual information taken from the NVT ASCII character set.
+
+ The SONET path hierarchy is based upon the SONET line capacity.
+ Configuration examples follow the diagram below, which depicts the SONET
+ Path hierarchy.
+
+ OC-192/STM-64
+ ^
+ |
+ OC-48/STM-16 (1-4)
+ ^
+ |
+ OC-12/STM-4 (1-4)
+ ^
+ |
+ OC-3/STM-1 (1-4)
+ ^
+ |
+ OC-1/STM-0 (1-3)
+ ^
+ |
+ ^----------------^----------------^
+ | | |
+ DS3 (1) VT1.5/TU11 DS1 (1-28) VT2/TU12 (1-21)
+
+ For Line Speed = OC-48/STM-16:
+ When the entire capacity contains only one path, no specifier
+ is used.
+
+ OC-12/STM-4 Path
+ To specify an OC-12 path over OC-48 provide a single digit of
+ the form a where:
+
+ a - OC-12/STM-4 path number (1-4)
+
+ OC-3/STM-1 Path
+ To specify an OC-3 Path over OC-48 provide two digits of the
+ form a/b where:
+
+ a - OC-12/STM-4 path number (1-4)
+ b - OC-3/STM-1 path within the OC-12 (1-4)
+
+ OC-1/STM-0 Path
+ To specify an OC1 Path over OC-48 provide three digits of the
+ form a/b/c where:
+
+ a - OC-12/STM-4 path number (1-4)
+ b - OC-3/STM-1 path number within OC-12 (1-4)
+ c - OC-1/STM-0 path number within OC-3 (1-3)
+
+ For Line Speed = OC-12/STM-4:
+
+ OC-12/STM-4 Path:
+ When entire line capacity contains only one path, no
+ channel-specifier is used.
+
+ OC-3/STM-1 Path:
+ To specify an OC-3 path over OC-12 provide a single digit of
+ the form a where:
+
+ a - OC-3/STM-1 path within the OC-12 (1-4)
+
+ OC-1 Path:
+ To specify an OC-1 path over OC-12 provide two digits of the
+ form a/b where:
+
+ a - OC-3/STM-1 path within the OC-12 (1-4)
+ b - OC-1/STM-0 path within the OC-3 (1-3)
+
+ For Line Speed = OC-3/STM-1:
+
+ OC-3/STM-1 Path:
+ When entire line capacity contains only one path, no
+ channel-specifier is used.
+
+ OC-1 Path:
+ To specify an OC-1 path over OC-3 provide one digit of the
+ form a where:
+
+ a - OC-1/STM-1 path within the OC-3 (1-3) "
+ REFERENCE
+ "RFC 854: NVT ASCII character set. See SNMPv2-TC.DisplayString
+ DESCRIPTION for a summary."
+ SYNTAX OCTET STRING (SIZE(0..32))
+
+JuniSonetPathC2ByteOverride ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "SONET Path c2 overhead byte.
+
+ This value should only be set in cases where the value set by
+ the upper interface type needs to be overridden. Standard values
+ are:
+ 0 Unequipped
+ 1 Nonspecific
+ 2 Floating VT
+ 4 Asyncronous mapping of DS3
+ 19 ATM
+ 22 HDLC over Sonet - scrambling enabled
+ 207 HDLC over Sonet - no scrambling"
+ SYNTAX Integer32 (0..255)
+
+JuniSonetVTType ::= TEXTUAL-CONVENTION
+ STATUS deprecated
+ DESCRIPTION
+ "The SONET Virtual Tributary Type. This TC has been deprecated because
+ RFC2558 provides this information in SONET-MIB.sonetVTCurrentWidth."
+ SYNTAX INTEGER {
+ tribVT15TU11(0),
+ tribVT20TU12(1),
+ tribVT3(3),
+ tribVT6(4),
+ tribVT6c(5) }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Managed objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSonetObjects OBJECT IDENTIFIER ::= { juniSonetMIB 1 }
+juniSonetPathObjects OBJECT IDENTIFIER ::= { juniSonetMIB 2 }
+juniSonetVTObjects OBJECT IDENTIFIER ::= { juniSonetMIB 3 }
+
+
+-- /////////////////////////////////////////////////////////////////////////////
+--
+-- SONET Interfaces
+--
+-- /////////////////////////////////////////////////////////////////////////////
+--
+-- The SONET Interface Table
+--
+juniSonetMediumTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSonetMediumEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains entries for SONET interfaces present in the
+ system."
+ ::= { juniSonetObjects 1 }
+
+juniSonetMediumEntry OBJECT-TYPE
+ SYNTAX JuniSonetMediumEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Each entry describes the characteristics of an SONET interface."
+ INDEX { ifIndex }
+ ::= { juniSonetMediumTable 1 }
+
+JuniSonetMediumEntry ::= SEQUENCE {
+ juniSonetMediumType INTEGER,
+ juniSonetMediumLoopbackConfig INTEGER,
+ juniSonetMediumTimingSource INTEGER,
+ juniSonetMediumCircuitIdentifier DisplayString,
+ juniSonetMediumTriggerAlarms BITS,
+ juniSonetMediumTriggerDelay Integer32 }
+
+juniSonetMediumType OBJECT-TYPE
+ SYNTAX INTEGER {
+ sonet(1),
+ sdh(2) }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "This variable identifies whether a SONET or a SDH signal is used across
+ this interface. This object was deprecated because the same information
+ is provided by the SONET-MIB.sonetMediumType object (RFC 2558)."
+ ::= { juniSonetMediumEntry 1 }
+
+juniSonetMediumLoopbackConfig OBJECT-TYPE
+ SYNTAX INTEGER {
+ sonetNoLoop(0),
+ sonetFacilityLoop(1),
+ sonetTerminalLoop(2),
+ sonetOtherLoop(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The current loopback state of the SONET/SDH interface.
+ The values mean:
+ sonetNoLoop Not in the loopback state. A device that is not
+ capable of performing a loopback on this
+ interface shall always return this value.
+ sonetFacilityLoop The received signal at this interface is looped
+ back out through the corresponding transmitter in
+ the return direction.
+ sonetTerminalLoop The signal that is about to be transmitted is
+ connected to the associated incoming receiver.
+ sonetOtherLoop Loopbacks that are not defined here."
+ ::= { juniSonetMediumEntry 2 }
+
+juniSonetMediumTimingSource OBJECT-TYPE
+ SYNTAX INTEGER {
+ loop(0),
+ internalModule(1),
+ internalChassis(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Selects the source from which transmit timing is derived.
+ loop timing is recovered from the receiver
+ internalModule timing is from the module associated with this
+ interface
+ internalChassis timing is taken from the internal system timing
+ reference "
+ ::= { juniSonetMediumEntry 3 }
+
+juniSonetMediumCircuitIdentifier OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "This variable contains the transmission vendor's circuit identifier,
+ for the purpose of facilitating troubleshooting. This object was
+ deprecated because the same information is provided by the
+ SONET-MIB.sonetMediumCircuitIdentifier object (RFC 2558)."
+ ::= { juniSonetMediumEntry 4 }
+
+juniSonetMediumTriggerAlarms OBJECT-TYPE
+ SYNTAX BITS {
+ sectionLOS(0),
+ sectionLOF(1),
+ lineAIS(2),
+ lineRDI(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarms that are used in the operational status calculation for this
+ SONET interface.
+ sectionLOS When this bit is set, section LOS is used for
+ operational status calculation.
+ sectionLOF When this bit is set, section LOF is used for
+ operational status calculation.
+ lineAIS When this bit is set, line AIS is used for operational
+ status calculation.
+ lineRDI When this bit is set, line RDI is used for operational
+ status calculation.
+
+ The value of this object defaults to all the bits set, indicating all of
+ the alarms are used for the operational status calculation."
+ DEFVAL { { sectionLOS, sectionLOS, lineAIS, lineRDI } }
+ ::= { juniSonetMediumEntry 5 }
+
+juniSonetMediumTriggerDelay OBJECT-TYPE
+ SYNTAX Integer32 (0..2500)
+ UNITS "ms"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The time delay (in milliseconds) before a defect is accepted as an
+ alarm for this SONET interface."
+ DEFVAL { 2500 }
+ ::= { juniSonetMediumEntry 6 }
+
+
+--
+-- The SONET Path Capabilities Table
+--
+juniSonetPathCapabilityTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSonetPathCapabilityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains entries for SONET Paths present in the system."
+ ::= { juniSonetPathObjects 1 }
+
+juniSonetPathCapabilityEntry OBJECT-TYPE
+ SYNTAX JuniSonetPathCapabilityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Each entry describes the SONET path capability of a SONET interface.
+ This table is index by the ifIndex of the SONET interface."
+ INDEX { ifIndex }
+ ::= { juniSonetPathCapabilityTable 1 }
+
+JuniSonetPathCapabilityEntry ::= SEQUENCE {
+ juniSonetPathRemoveFlag TruthValue,
+ juniSonetPathChannelized TruthValue,
+ juniSonetPathMaximumChannels Unsigned32,
+ juniSonetPathMinimumPathSpeed JuniSonetLineSpeed,
+ juniSonetPathMaximumPathSpeed JuniSonetLineSpeed }
+
+juniSonetPathRemoveFlag OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable identifies whether a SONET/SDH supports the deletion of
+ SONET Paths. A value of true(1) indicates the SONET path is removable;
+ a value of false(2) indicates the SONET path cannot be removed."
+ ::= { juniSonetPathCapabilityEntry 1 }
+
+juniSonetPathChannelized OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Identifies whether or not this SONET interface supports channelization.
+ A value of true(1) indicates the SONET path is channelized; a value of
+ false(2) indicates the SONET path is not channelized."
+ ::= { juniSonetPathCapabilityEntry 2 }
+
+juniSonetPathMaximumChannels OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Identifies the maximum number of SONET paths/channels for this
+ interface."
+ ::= { juniSonetPathCapabilityEntry 3 }
+
+juniSonetPathMinimumPathSpeed OBJECT-TYPE
+ SYNTAX JuniSonetLineSpeed
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Identifies the minimum SONET path speed for this interface."
+ ::= { juniSonetPathCapabilityEntry 4 }
+
+juniSonetPathMaximumPathSpeed OBJECT-TYPE
+ SYNTAX JuniSonetLineSpeed
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Identifies the maximum SONET path speed for this interface."
+ ::= { juniSonetPathCapabilityEntry 5 }
+
+
+--
+-- The SONET Path Interface Objects
+--
+juniSonetPathNextIfIndex OBJECT-TYPE
+ SYNTAX JuniNextIfIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Coordinate ifIndex value allocation for entries in juniSonetPathTable.
+
+ A GET of this object returns the next available ifIndex value to be used
+ to create an entry in the associated interface table; or zero, if no
+ valid ifIndex value is available. This object also returns a value of
+ zero when it is the lexicographic successor of a varbind presented in an
+ SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
+ that ifIndex allocation is unintended.
+
+ Successive GETs will typically return different values, thus avoiding
+ collisions among cooperating management clients seeking to create table
+ entries simultaneously."
+ ::= { juniSonetPathObjects 2 }
+
+
+--
+-- The SONET Path Interface Table
+--
+juniSonetPathTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSonetPathEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains entries for SONET Path interfaces present in the
+ system."
+ ::= { juniSonetPathObjects 3 }
+
+juniSonetPathEntry OBJECT-TYPE
+ SYNTAX JuniSonetPathEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Each entry describes the characteristics of an SONET Path interface."
+ INDEX { juniSonetPathIfIndex }
+ ::= { juniSonetPathTable 1 }
+
+JuniSonetPathEntry ::= SEQUENCE {
+ juniSonetPathIfIndex InterfaceIndex,
+ juniSonetPathLogicalChannel JuniSonetLogicalPathChannel,
+ juniSonetPathSpeed JuniSonetLineSpeed,
+ juniSonetPathHierarchy JuniSonetPathHierarchy,
+ juniSonetPathLowerIfIndex InterfaceIndexOrZero,
+ juniSonetPathRowStatus RowStatus,
+ juniSonetPathTriggerAlarms BITS,
+ juniSonetPathC2ByteOverrideFlag TruthValue,
+ juniSonetPathC2ByteOverride JuniSonetPathC2ByteOverride,
+ juniSonetPathTriggerDelay Integer32,
+ juniSonetPathEventStatus Unsigned32 }
+
+juniSonetPathIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The ifIndex of the SONET Path interface. When creating entries in this
+ table, suitable values for this object are determined by reading
+ juniSonetPathNextIfIndex."
+ ::= { juniSonetPathEntry 1 }
+
+juniSonetPathLogicalChannel OBJECT-TYPE
+ SYNTAX JuniSonetLogicalPathChannel
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The logical channel number assigned to this SONET Path. If the
+ underlying SONET interface does not support channelization, the value of
+ this object is zero."
+ ::= { juniSonetPathEntry 2 }
+
+juniSonetPathSpeed OBJECT-TYPE
+ SYNTAX JuniSonetLineSpeed
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The line speed associated with this SONET PATH."
+ ::= { juniSonetPathEntry 3 }
+
+juniSonetPathHierarchy OBJECT-TYPE
+ SYNTAX JuniSonetPathHierarchy
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The SONET Path hierarchy associated with this path."
+ ::= { juniSonetPathEntry 4 }
+
+juniSonetPathLowerIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The ifIndex of the interface over which this SONET Path interface is to
+ be layered - typically a SONET/SDH interface. A value of zero indicates
+ no layering. An implementation may choose to require that a nonzero
+ value be configured at entry creation."
+ ::= { juniSonetPathEntry 5 }
+
+juniSonetPathRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Controls creation/deletion of entries in this table according to the
+ RowStatus textual convention, constrained to support the following
+ values only:
+ createAndGo
+ destroy
+
+ To create an entry in this table, the following entry objects MUST be
+ explicitly configured:
+ juniSonetPathRowStatus
+ juniSonetPathSpeed
+ juniSonetPathHierarchy
+ juniSonetPathLowerIfIndex
+
+ The logical channel may optionally be specified. If it is not specified
+ an unused logical channel value will be assigned by the system.
+ juniSonetPathLogicalChannel
+
+ In addition, when creating an entry the following conditions must hold:
+ A value for juniSonetPathIfIndex must have been determined
+ previously, by reading juniSonetPathNextIfIndex.
+
+ The interface identified by the juniSonetPathLowerIfIndex must
+ exist.
+
+ The juniSonetPathSpeed must be consistent with the speed for the
+ channel specified by the juniSonetPathHierarchy, based on the speed
+ of the interface identified by the juniSonetPathLowerIfIndex.
+
+ A corresponding entry in ifTable/ifXTable/juniIfTable is created/
+ destroyed as a result of creating/destroying an entry in this table."
+ ::= { juniSonetPathEntry 6 }
+
+juniSonetPathTriggerAlarms OBJECT-TYPE
+ SYNTAX BITS {
+ pathLOP(0),
+ pathAIS(1),
+ pathRDI(2) }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The path alarms that are used in the operational status calculation for
+ this SONET Path.
+ pathLOP When this bit is set, path LOP is used for operational
+ status calculation. This bit may not be modified.
+ pathAIS When this bit is set, path AIS is used for operational
+ status calculation. This bit may not be modified.
+ pathRDI When this bit is set, path RDI is used for operational
+ status calculation.
+
+ The value of this object defaults to bits 0 and 1 set, indication LOP
+ and AIS will be used for operational status calculation this SONET
+ Path."
+ DEFVAL { { pathLOP, pathAIS } }
+ ::= { juniSonetPathEntry 7 }
+
+juniSonetPathC2ByteOverrideFlag OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The path overhead c2 transmit override enable. If set to true(1),
+ juniSonetPathC2Byte override value must be specified. If set to
+ false(2), c2 byte will be automatically set by the system based on the
+ upper interface type."
+ DEFVAL { false }
+ ::= { juniSonetPathEntry 8 }
+
+juniSonetPathC2ByteOverride OBJECT-TYPE
+ SYNTAX JuniSonetPathC2ByteOverride
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The path overhead c2 transmit and expected value for this SONET Path."
+ DEFVAL { 0 }
+ ::= { juniSonetPathEntry 9 }
+
+juniSonetPathTriggerDelay OBJECT-TYPE
+ SYNTAX Integer32 (0..2500)
+ UNITS "ms"
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The time delay (in milliseconds) before a defect is accepted as an
+ alarm for this SONET Path."
+ DEFVAL { 2500 }
+ ::= { juniSonetPathEntry 10 }
+
+juniSonetPathEventStatus OBJECT-TYPE
+ SYNTAX Unsigned32 (0..32767)
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "This variable specifies which events have occurred in the current 15
+ minute interval. The value represents a vector of bits, each specifying
+ a unique event:
+ - Bit 0 Rising threshold alarm, sonetPathCurrentESs.
+ - Bit 1 Rising threshold alarm, sonetPathCurrentSESs.
+ - Bit 2 Reserved.
+ - Bit 3 Rising threshold alarm, sonetPathCurrentCVs.
+ - Bit 4 Rising threshold alarm, sonetPathCurrentUASs.
+ - Bit 5 LOP failure indication.
+ - Bit 6 LOP failure cleared.
+ - Bit 7 AIS failure indication.
+ - Bit 8 AIS failure cleared.
+ - Bit 9 RFI indication.
+ - Bit 10 RFI cleared.
+ - Bit 11 UNEQ failure indication.
+ - Bit 12 UNEQ failure cleared.
+ - Bit 13 PLM failure indication.
+ - Bit 14 PLM failure cleared. "
+ ::= { juniSonetPathEntry 11 }
+
+
+--
+-- The SONET Virtual Tributary Interface Objects
+--
+juniSonetVTNextIfIndex OBJECT-TYPE
+ SYNTAX JuniNextIfIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Coordinate ifIndex value allocation for entries in juniSonetVTTable.
+
+ A GET of this object returns the next available ifIndex value to be used
+ to create an entry in the associated interface table; or zero, if no
+ valid ifIndex value is available. This object also returns a value of
+ zero when it is the lexicographic successor of a varbind presented in an
+ SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
+ that ifIndex allocation is unintended.
+
+ Successive GETs will typically return different values, thus avoiding
+ collisions among cooperating management clients seeking to create table
+ entries simultaneously."
+ ::= { juniSonetVTObjects 1 }
+
+
+--
+-- The SONET Virtual Tributary Interface Table
+--
+juniSonetVTTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF JuniSonetVTEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains entries for SONET Virtual Tributary interfaces
+ present in the system. This table augments the standard
+ SONET-MIB.sonetVTCurrentTable."
+ ::= { juniSonetVTObjects 2 }
+
+juniSonetVTEntry OBJECT-TYPE
+ SYNTAX JuniSonetVTEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Each entry describes the characteristics of an SONET Virtual Tributary
+ interface."
+ INDEX { juniSonetVTIfIndex }
+ ::= { juniSonetVTTable 1 }
+
+JuniSonetVTEntry ::= SEQUENCE {
+ juniSonetVTIfIndex InterfaceIndex,
+ juniSonetVTPathLogicalChannel JuniSonetLogicalPathChannel,
+ juniSonetVTType JuniSonetVTType,
+ juniSonetVTPathPayload Unsigned32,
+ juniSonetVTTributaryGroup Unsigned32,
+ juniSonetVTTributarySubChannel Unsigned32,
+ juniSonetVTLowerIfIndex InterfaceIndexOrZero,
+ juniSonetVTRowStatus RowStatus }
+
+juniSonetVTIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The ifIndex of the SONET Virtual Tributary interface. When creating
+ entries in this table, suitable values for this object are determined by
+ reading juniSonetVTNextIfIndex."
+ ::= { juniSonetVTEntry 1 }
+
+juniSonetVTPathLogicalChannel OBJECT-TYPE
+ SYNTAX JuniSonetLogicalPathChannel
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The SONET Path logical channel number associated with this virtual
+ tributary."
+ ::= { juniSonetVTEntry 2 }
+
+juniSonetVTType OBJECT-TYPE
+ SYNTAX JuniSonetVTType
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "The SONET virtual tributary type. This object was deprecated because
+ the same information is provided in the SONET-MIB.sonetVTCurrentWidth
+ object."
+ ::= { juniSonetVTEntry 3 }
+
+juniSonetVTPathPayload OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The SONET Path payload number associated with this virtual tributary.
+ For SDH mode, this is a value with a range from 1-3. For SONET mode,
+ the value of this object is always 1."
+ ::= { juniSonetVTEntry 4 }
+
+juniSonetVTTributaryGroup OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The SONET Path group number for this virtual tributary. In SONET and
+ SDH mode, the value of this object is 1-7."
+ ::= { juniSonetVTEntry 5 }
+
+juniSonetVTTributarySubChannel OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Specifies the virtual tributary number within the tributary group
+ defined by juniSonetVTTributaryGroup object. The value of this object
+ ranges from 1-4 if the tributary type is tribVT15/TU11(0); and the
+ values 1-3 if the tributary type is tribVT20/TU12(1)."
+ ::= { juniSonetVTEntry 6 }
+
+juniSonetVTLowerIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The ifIndex of the interface over which this SONET Virtual Tributary
+ interface is to be layered - typically a SONET PATH interface.
+
+ A value of zero indicates no layering. An implementation may choose to
+ require that a nonzero value be configured at entry creation."
+ ::= { juniSonetVTEntry 7 }
+
+juniSonetVTRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Controls creation/deletion of entries in this table according to the
+ RowStatus textual convention, constrained to support the following
+ values only:
+ createAndGo
+ destroy
+
+ To create an entry in this table, the following entry objects MUST be
+ explicitly configured:
+ juniSonetVTRowStatus
+ juniSonetVTPathLogicalChannel
+ juniSonetVTType
+ juniSonetVTPathPayload
+ juniSonetVTTributaryGroup
+ juniSonetVTTributarySubChannel
+ juniSonetVTLowerIfIndex
+
+ In addition, when creating an entry the following conditions must hold:
+
+ A value for juniSonetVTIfIndex must have been determined previously,
+ by reading juniSonetVTNextIfIndex.
+
+ The interface identified by juniSonetVTLowerIfIndex must exist.
+
+ A corresponding entry in ifTable/ifXTable/juniIfTable is created/
+ destroyed as a result of creating/destroying an entry in this table."
+ ::= { juniSonetVTEntry 8 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Notification control objects
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSonetTrapControl OBJECT IDENTIFIER ::= { juniSonetMIB 5 }
+
+juniSonetPathEventIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "The ifIndex of the SONET Path interface. This is the same value as
+ juniSonetPathIfIndex for the interface that is reporting an event."
+ ::= { juniSonetTrapControl 1 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Notifications
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- The following two OBJECT IDENTIFIERS are used to define SNMPv2 notifications
+-- that are easily translated into SNMPv1 Traps.
+juniSonetTraps OBJECT IDENTIFIER ::= { juniSonetMIB 6 }
+juniSonetTrapPrefix OBJECT IDENTIFIER ::= { juniSonetTraps 0 }
+
+juniSonetPathEvents NOTIFICATION-TYPE
+ OBJECTS {
+ juniSonetPathEventIfIndex,
+ juniSonetPathEventStatus,
+ ifAlias }
+ STATUS current
+ DESCRIPTION
+ "This trap reports SONET path events for the failures and normal
+ conditions of the SONET path entity."
+ ::= { juniSonetTrapPrefix 1 }
+
+
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+-- Conformance information
+-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+juniSonetConformance OBJECT IDENTIFIER ::= { juniSonetMIB 4 }
+juniSonetCompliances OBJECT IDENTIFIER ::= { juniSonetConformance 1 }
+juniSonetGroups OBJECT IDENTIFIER ::= { juniSonetConformance 2 }
+
+--
+-- compliance statements
+--
+juniSonetCompliance MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete compliance statement for entities which implement the Juniper
+ SONET MIB. This statement became obsolete when the SONET Path and SONET
+ VT groups of objects were added."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniSonetGroup }
+ ::= { juniSonetCompliances 1 } -- JUNOSe 1.0
+
+juniSonetCompliance2 MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete compliance statement for entities which implement the Juniper
+ SONET MIB. This statement became obsolete when the juniSonetMediumType,
+ juniSonetMediumCircuitIdentifier and juniSonetVTType objects were
+ deprecated."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniSonetGroup,
+ juniSonetPathGroup }
+ GROUP juniSonetVirtualTributaryGroup
+ DESCRIPTION
+ "This group is mandatory only for those entities that support
+ SONET virtual tributaries."
+ ::= { juniSonetCompliances 2 } -- JUNOSe 3.0
+
+juniSonetCompliance3 MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete compliance statement for entities which implement the Juniper
+ SONET MIB. This statement became obsolete when support was added for
+ alarm triggers and path c2 byte override."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniSonetGroup2,
+ juniSonetPathGroup }
+ GROUP juniSonetVirtualTributaryGroup2
+ DESCRIPTION
+ "This group is mandatory only for those entities that support
+ SONET virtual tributaries."
+ ::= { juniSonetCompliances 3 } -- JUNOSe 3.2
+
+juniSonetCompliance4 MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete compliance statement for entities which implement the Juniper
+ SONET MIB. This statement became obsolete when the SONET Path event
+ status and notification support was added."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniSonetGroup3,
+ juniSonetPathGroup2 }
+ GROUP juniSonetVirtualTributaryGroup2
+ DESCRIPTION
+ "This group is mandatory only for those entities that support
+ SONET virtual tributaries."
+ ::= { juniSonetCompliances 4 } -- JUNOSe 5.0
+
+juniSonetCompliance5 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for entities which implement the Juniper SONET
+ MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ juniSonetGroup3,
+ juniSonetPathGroup3,
+ juniSonetPathNotificationGroup }
+ GROUP juniSonetVirtualTributaryGroup2
+ DESCRIPTION
+ "This group is mandatory only for those entities that support
+ SONET virtual tributaries."
+ ::= { juniSonetCompliances 5 } -- JUNOSe 5.1
+
+
+--
+-- units of conformance
+--
+juniSonetGroup OBJECT-GROUP
+ OBJECTS {
+ juniSonetMediumType,
+ juniSonetMediumLoopbackConfig,
+ juniSonetMediumTimingSource,
+ juniSonetMediumCircuitIdentifier }
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete collection of objects providing management of SONET/SDH
+ interfaces in a Juniper product. This group became obsolete when the
+ juniSonetMediumType and juniSonetMediumCircuitIdentifier objects were
+ deprecated."
+ ::= { juniSonetGroups 1 } -- JUNOSe 1.0
+
+juniSonetPathGroup OBJECT-GROUP
+ OBJECTS {
+ juniSonetPathRemoveFlag,
+ juniSonetPathChannelized,
+ juniSonetPathMaximumChannels,
+ juniSonetPathMinimumPathSpeed,
+ juniSonetPathMaximumPathSpeed,
+ juniSonetPathNextIfIndex,
+ juniSonetPathLogicalChannel,
+ juniSonetPathSpeed,
+ juniSonetPathHierarchy,
+ juniSonetPathLowerIfIndex,
+ juniSonetPathRowStatus }
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete collection of objects providing management of SONET/SDH Path
+ interfaces in a Juniper product. This group became obsolete when new
+ SONET path objects were added."
+ ::= { juniSonetGroups 2 } -- JUNOSe 3.0
+
+juniSonetVirtualTributaryGroup OBJECT-GROUP
+ OBJECTS {
+ juniSonetVTNextIfIndex,
+ juniSonetVTPathLogicalChannel,
+ juniSonetVTType,
+ juniSonetVTPathPayload,
+ juniSonetVTTributaryGroup,
+ juniSonetVTTributarySubChannel,
+ juniSonetVTLowerIfIndex,
+ juniSonetVTRowStatus }
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete collection of objects providing management of SONET virtual
+ tributaries in a Juniper product. This group became obsolete when
+ juniSonetVTType was deprecated."
+ ::= { juniSonetGroups 3 } -- JUNOSe 3.0
+
+juniSonetGroup2 OBJECT-GROUP
+ OBJECTS {
+ juniSonetMediumLoopbackConfig,
+ juniSonetMediumTimingSource }
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete collection of objects providing management of SONET/SDH
+ interfaces in a Juniper product. This group became obsolete when
+ juniSonetMediumTriggerAlarms was added."
+ ::= { juniSonetGroups 4 } -- JUNOSe 3.2
+
+juniSonetVirtualTributaryGroup2 OBJECT-GROUP
+ OBJECTS {
+ juniSonetVTNextIfIndex,
+ juniSonetVTPathLogicalChannel,
+ juniSonetVTPathPayload,
+ juniSonetVTTributaryGroup,
+ juniSonetVTTributarySubChannel,
+ juniSonetVTLowerIfIndex,
+ juniSonetVTRowStatus }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing management of SONET virtual
+ tributaries in a Juniper product."
+ ::= { juniSonetGroups 5 } -- JUNOSe 3.2
+
+juniSonetDeprecatedMediumGroup OBJECT-GROUP
+ OBJECTS {
+ juniSonetMediumType,
+ juniSonetMediumCircuitIdentifier }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of deprecated objects providing management of SONET/SDH
+ interfaces in a Juniper product. This group is deprecated because the
+ same information is provided by SONET-MIB objects (RFC 2558). Support
+ for the objects in this group will be phased out over time."
+ ::= { juniSonetGroups 6 } -- JUNOSe 3.2
+
+juniSonetDeprecatedVTGroup OBJECT-GROUP
+ OBJECTS {
+ juniSonetVTType }
+ STATUS deprecated
+ DESCRIPTION
+ "A deprecated object providing management of SONET/SDH VT interfaces in
+ a Juniper product. This group is deprecated because the same
+ information is provided by SONET-MIB objects (RFC 2558). Support for
+ the VT type object will be phased out over time."
+ ::= { juniSonetGroups 7 } -- JUNOSe 3.2
+
+juniSonetGroup3 OBJECT-GROUP
+ OBJECTS {
+ juniSonetMediumLoopbackConfig,
+ juniSonetMediumTimingSource,
+ juniSonetMediumTriggerAlarms,
+ juniSonetMediumTriggerDelay }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing management of SONET/SDH interfaces in
+ a Juniper product."
+ ::= { juniSonetGroups 8 } -- JUNOSe 5.0
+
+juniSonetPathGroup2 OBJECT-GROUP
+ OBJECTS {
+ juniSonetPathRemoveFlag,
+ juniSonetPathChannelized,
+ juniSonetPathMaximumChannels,
+ juniSonetPathMinimumPathSpeed,
+ juniSonetPathMaximumPathSpeed,
+ juniSonetPathNextIfIndex,
+ juniSonetPathLogicalChannel,
+ juniSonetPathSpeed,
+ juniSonetPathHierarchy,
+ juniSonetPathLowerIfIndex,
+ juniSonetPathRowStatus,
+ juniSonetPathTriggerAlarms,
+ juniSonetPathC2ByteOverrideFlag,
+ juniSonetPathC2ByteOverride,
+ juniSonetPathTriggerDelay }
+ STATUS obsolete
+ DESCRIPTION
+ "Obsolete collection of management objects providing management of
+ SONET/SDH Path interfaces in a Juniper product. This group became
+ obsolete when path event notification support was added."
+ ::= { juniSonetGroups 9 } -- JUNOSe 5.0
+
+juniSonetPathGroup3 OBJECT-GROUP
+ OBJECTS {
+ juniSonetPathRemoveFlag,
+ juniSonetPathChannelized,
+ juniSonetPathMaximumChannels,
+ juniSonetPathMinimumPathSpeed,
+ juniSonetPathMaximumPathSpeed,
+ juniSonetPathNextIfIndex,
+ juniSonetPathLogicalChannel,
+ juniSonetPathSpeed,
+ juniSonetPathHierarchy,
+ juniSonetPathLowerIfIndex,
+ juniSonetPathRowStatus,
+ juniSonetPathTriggerAlarms,
+ juniSonetPathC2ByteOverrideFlag,
+ juniSonetPathC2ByteOverride,
+ juniSonetPathTriggerDelay,
+ juniSonetPathEventIfIndex,
+ juniSonetPathEventStatus }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing management of SONET/SDH Path
+ interfaces in a Juniper product."
+ ::= { juniSonetGroups 10 } -- JUNOSe 5.1
+
+juniSonetPathNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ juniSonetPathEvents }
+ STATUS current
+ DESCRIPTION
+ "A management notification for signaling SONET Path interface status
+ changes in a Juniper product."
+ ::= { juniSonetGroups 11 } -- JUNOSe 5.1
+
+END