+-- $Id: MBG-LANTIME-MIB.mib 1.1 2012/08/31 06:25:09 philipp TRASH $
+-- $Name: $
+--
+-- Copyright (c) Meinberg Funkuhren, 31812 Bad Pyrmont, Germany
+--
+-- Description:
+-- Management Information Base for Meinberg LANTIME time server
+--
+-- **************************************************************************
+--
+-- $Log: MBG-LANTIME-MIB.mib $
+-- Revision 1.1 2012/08/31 06:25:09 philipp
+-- Revision 1.9 2011/30/03 12:00:00 philipp
+-- - added mbgLtPtp and PTP traps objects
+-- Revision 1.8 2011/28/02 10:12:45 heiko
+-- - added PTP objects
+-- Revision 1.7 2008/09/11 08:05:53 heiko
+-- - added MRS objects and Traps
+-- Revision 1.3.1.1 2008/09/10 13:18:48 heiko
+-- - 5.26e added MRS (XMR) Objects and Traps
+-- Revision 1.3 2006/08/24 13:07:55 heiko
+-- - now up to 7 external NTP servers
+-- - "prefer" flag can be set for each external NTP server
+-- - renumbered the remaining objects in mbgLtCfgNtp
+-- Revision 1.2 2006/08/23 09:51:05 heiko
+-- - new object mbgLtCmdSetRefTime for setting the time of the refclock via SNMP
+-- Revision 1.1 2006/08/23 09:35:41 heiko
+--
+-- **************************************************************************
+
+MBG-SNMP-LT-MIB DEFINITIONS ::= BEGIN
+
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE , Integer32, NOTIFICATION-TYPE
+ FROM SNMPv2-SMI
+ MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
+ FROM SNMPv2-CONF
+ DisplayString FROM SNMPv2-TC
+
+ mbgSnmpRoot FROM MBG-SNMP-ROOT-MIB;
+
+
+mbgLantime MODULE-IDENTITY
+ LAST-UPDATED "201201250745Z"
+ ORGANIZATION "www.meinberg.de"
+ CONTACT-INFO
+ "postal: Meinberg Funkuhren
+ Lange Wand 9
+ 31812 Bad Pyrmont
+ Germany
+
+ email: info@meinberg.de"
+ DESCRIPTION
+ " Meinberg SNMP Management Information Base "
+ REVISION "201201250745Z"
+ DESCRIPTION
+ " Changed MIB module name."
+ REVISION "201103300000Z"
+ DESCRIPTION
+ " Version 5.32l, added mbgLtPtp and PTP traps objects"
+ REVISION "201103290000Z"
+ DESCRIPTION
+ " Version 5.32c, added mbgLtPtp Branch with PTP information objects "
+ REVISION "201001190000Z"
+ DESCRIPTION
+ " Revised edition (V5.30i), added NTP Sync Trap definition"
+ REVISION "200912030000Z"
+ DESCRIPTION
+ " Revised edition (V5.30g), added NTP Client Monitoring Trap definition"
+ REVISION "200809100000Z"
+ DESCRIPTION
+ "Revised edition (V5.26e), added MRS Objects and Traps"
+ REVISION "200807150000Z"
+ DESCRIPTION
+ "Revised edition (V5.26), added ReceiverSync Trap (14)"
+ REVISION "200806150000Z"
+ DESCRIPTION
+ "Revised edition (V5.25), changed postal address"
+ REVISION "200608230000Z"
+ DESCRIPTION
+ "Revised edition (V4.38), added mbgLtCmdSetRefTime"
+ REVISION "200603200000Z"
+ DESCRIPTION
+ "Revised edition (V4.36) with changed Trap OID base"
+ REVISION "200507080000Z"
+ DESCRIPTION
+ "Revised edition (V4.25)"
+ ::= { mbgSnmpRoot 3 }
+
+--
+-- General LANTIME information objects
+--
+
+mbgLtInfo OBJECT IDENTIFIER ::= { mbgLantime 0 }
+
+mbgLtFirmwareVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "shows the installed firmware version of your LANTIME"
+ ::= { mbgLtInfo 1 }
+
+mbgLtFirmwareVersionVal OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "shows the installed firmware version of your LANTIME as an Integer32 value"
+ ::= { mbgLtInfo 2 }
+
+
+--
+-- Lantime NTP states
+--
+mbgLtNtp OBJECT IDENTIFIER ::= { mbgLantime 1 }
+
+
+
+mbgLtNtpCurrentState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "actual state of the NTP as string"
+ --- possible strings:
+ --- "not synchronized"
+ --- "no good refclock (->local)"
+ --- "sync to external refclock"
+ --- "sync to serial refclock"
+ --- "Normal Operation (->PPS)"
+ --- "Normal Operation (->internal refclock)"
+ --- internal refclocks (PlugIn cards) have to be linked
+ --- via /dev/refclock-2 and /dev/refclock-3
+ ::= { mbgLtNtp 1 }
+
+mbgLtNtpCurrentStateVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notSynchronized(0),
+ noGoodRefclock(1),
+ syncToExtRefclock(2),
+ syncToSerialRefclock(3),
+ normalOperationPPS(4),
+ normalOperationRefclock(5),
+ unknown(99)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current state of the NTP as Integer32 value"
+ --- "0 : not synchronized"
+ --- "1 : no good refclock (->local)"
+ --- "2 : sync to external refclock"
+ --- "3 : sync to serial refclock"
+ --- "4 : Normal Operation (->PPS)"
+ --- "5 : Normal Operation (->internal refclock)"
+ DEFVAL { 99 }
+ ::= { mbgLtNtp 2 }
+
+mbgLtNtpStratum OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Stratum value of the NTP "
+ DEFVAL { 99 }
+ ::= { mbgLtNtp 3 }
+
+mbgLtNtpActiveRefclockId OBJECT-TYPE
+ SYNTAX INTEGER {
+ localClock(0),
+ serialRefclock(1),
+ pps(2),
+ externalRefclock(3),
+ notSync(99)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index of the current refclock selected by the NTP "
+ --- "0 : local clock"
+ --- "1 : serial refclock
+ --- "2 : PPS (Lantime/RD: second serial refclock"
+ --- "3 : external Refclock (Lantime/RD: PPS)
+ --- "99: NTP has not sync to any refclock"
+ DEFVAL { 99 }
+ ::= { mbgLtNtp 4 }
+
+mbgLtNtpActiveRefclockName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Name of the current refclock selected by the NTP "
+ ::= { mbgLtNtp 5 }
+
+mbgLtNtpActiveRefclockOffset OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time offset between the current selected refclock and time of NTP as string"
+ ::= { mbgLtNtp 6 }
+
+mbgLtNtpActiveRefclockOffsetVal OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time offset in micro seconds between the current selected refclock and time of NTP "
+ DEFVAL { 1024000000 }
+ ::= { mbgLtNtp 7 }
+
+mbgLtNtpNumberOfRefclocks OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of refclocks configured in the NTP "
+ DEFVAL { 0 }
+ ::= { mbgLtNtp 8 }
+
+mbgLtNtpAuthKeyId OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Authentication Key ID of active refclock is active "
+ DEFVAL { 0 }
+ ::= { mbgLtNtp 9 }
+
+mbgLtNtpVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "integrated NTP version "
+ ::= { mbgLtNtp 10 }
+
+
+--
+-- Lantime Refclock states
+--
+
+mbgLtRefclock OBJECT IDENTIFIER ::= { mbgLantime 2 }
+
+mbgLtRefClockType OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Type of refclock connected to NTP time server "
+ ::= { mbgLtRefclock 1 }
+
+mbgLtRefClockTypeVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notavailable(0),
+ mbgGPS167(1),
+ mbgGPS167BGTTGP(2),
+ mbgPZF509(3),
+ mbgPZF509BGTTGP(4),
+ mbgSHS(5),
+ mbgSHSBGT(6),
+ mbgSHSFRC(7),
+ mbgSHSFRCBGT(8),
+ mbgTCR509(9),
+ mbgTCR509BGTTGP(10),
+ mbgRDT(11),
+ mbgRDTBGTTGP(12),
+ mbgEDT(13),
+ mbgEDTBGTTGP(14),
+ mbgAHS(15),
+ mbgDHS(16),
+ mbgNDT167(17),
+ mbgNDT167BGT(18),
+ mbgDCT(19),
+ mbgDCTBGT(20),
+ mbgSHSTCR(21),
+ mbgSHSTCRBGT(22)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Type of refclock connected to NTP time server as value"
+ --- " 0: not available"
+ --- " 1: GPS167 1HE"
+ --- " 2: GPS167 BGT/TGP"
+ --- " 3: PZF509 1HE"
+ --- " 4: PZF509 BGT/TGP"
+ --- " 5: SHS 1HE"
+ --- " 6: SHS BGT"
+ --- " 7: SHS-FRC 1HE"
+ --- " 8: SHS-FRC BGT"
+ --- " 9: TCR509 1HE"
+ --- "10: TCR509 BGT/TGP"
+ --- "11: RDT 1HE"
+ --- "12: RDT BGT/TGP"
+ --- "13: EDT 1HE"
+ --- "14: EDT BGT/TGP"
+ --- "15: AHS"
+ --- "16: DHS"
+ --- "17: NDT167 1HE"
+ --- "18: NDT167 BGT"
+ --- "19: DCT 1HE"
+ --- "20: DCT BGT"
+ --- "21: SHS-TCR 1HE"
+ --- "22: SHS-TCR BGT"
+
+
+ DEFVAL { 0 }
+ ::= { mbgLtRefclock 2 }
+
+
+mbgLtRefClockMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current mode of refclock connected to NTP time server "
+ ::= { mbgLtRefclock 3 }
+
+mbgLtRefClockModeVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notavailable(0),
+ normalOperation(1),
+ trackingSearching(2),
+ antennaFaulty(3),
+ warmBoot(4),
+ coldBoot(5),
+ antennaShortcircuit(6)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current mode of refclock connected to NTP time server as value"
+ --- " 0: not available"
+ --- " 1: Normal Operation"
+ --- " 2: Tracking/Searching"
+ --- " 3: Antenna Faulty"
+ --- " 4: Warm Boot"
+ --- " 5: Cold Boot"
+ --- " 6: Antenna Short Circuit"
+ DEFVAL { 0 }
+ ::= { mbgLtRefclock 4 }
+
+mbgLtRefGpsState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current State of GPS refclock conneted to NTP time server "
+ ::= { mbgLtRefclock 5 }
+
+mbgLtRefGpsStateVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notavailable(0),
+ synchronized(1),
+ notsynchronized(2)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current State of GPS refclock conneted to NTP time server as value"
+ --- " 0: not available"
+ --- " 1: synchronized"
+ --- " 2: not synchronized"
+ DEFVAL { 0 }
+ ::= { mbgLtRefclock 6 }
+
+mbgLtRefGpsPosition OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current Position of GPS refclock conneted to NTP time server "
+ ::= { mbgLtRefclock 7 }
+
+mbgLtRefGpsSatellites OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current Satellites in view and good of GPS refclock connected to NTP time server "
+ ::= { mbgLtRefclock 8 }
+
+mbgLtRefGpsSatellitesGood OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current good Satellites of GPS refclock connected to NTP time server as value"
+ ::= { mbgLtRefclock 9 }
+
+mbgLtRefGpsSatellitesInView OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current Satellites in view of GPS refclock conneted to NTP time server as value"
+ ::= { mbgLtRefclock 10 }
+
+mbgLtRefPzfState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current State of DCF77/PZF refclock connected to NTP time server "
+ ::= { mbgLtRefclock 11 }
+
+mbgLtRefPzfStateVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notavailable(0),
+ sync(1),
+ notsyncnow(2),
+ neversynced(3)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current State of DCF77/PZF refclock connected to NTP time server as value"
+ --- " 0: not available"
+ --- " 1: sync"
+ --- " 2: not sync now"
+ --- " 3: never synced"
+ DEFVAL { 0 }
+ ::= { mbgLtRefclock 12 }
+
+mbgLtRefPzfKorrelation OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current Korrelation of DCF77/PZF refclock connected to NTP time server "
+ --- " 0: not available"
+ --- " 254: Antenna Faulty"
+ --- " 255: Gsync"
+ --- " minimum of 60 to get synchronization"
+ --- " optimal value of 75"
+ DEFVAL { 0 }
+ ::= { mbgLtRefclock 13 }
+
+mbgLtRefPzfField OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current strength of field of DCF77/PZF refclock connected to NTP time server "
+ --- " 0: not available"
+ DEFVAL { 0 }
+ ::= { mbgLtRefclock 14 }
+
+
+mbgLtRefGpsMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current Mode of GPS refclock connected to NTP time server "
+ ::= { mbgLtRefclock 15 }
+
+mbgLtRefGpsModeVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notavailable(0),
+ normalOperation(1),
+ trackingSearching(2),
+ antennaFaulty(3),
+ warmBoot(4),
+ coldBoot(5),
+ antennaShortcircuit(6)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current Mode of GPS refclock connected to NTP time server as value"
+ --- " 0: not available"
+ --- " 1: Normal Operation"
+ --- " 2: Tracking/Searching"
+ --- " 3: Antenna Faulty"
+ --- " 4: Warm Boot"
+ --- " 5: Cold Boot"
+ --- " 6: Antenna Short Circuit"
+ --- This variable was formerly known as mbgLtRefClockModeVal
+ DEFVAL { 0 }
+ ::= { mbgLtRefclock 16 }
+
+mbgLtRefIrigMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current Mode of IRIG refclock conneted to NTP time server "
+ ::= { mbgLtRefclock 17 }
+
+mbgLtRefIrigModeVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notavailable(0),
+ locked(1),
+ notlocked(2),
+ telegramError(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current Mode of IRIG refclock conneted to NTP time server as value"
+ --- " 0: not available"
+ --- " 1: Sync (locked)"
+ --- " 2: Not sync (not locked)"
+ --- " 3: Telegram error"
+ DEFVAL { 0 }
+ ::= { mbgLtRefclock 18 }
+
+
+mbgLtRefPzfMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current Mode of PZF refclock connected to NTP time server "
+ ::= { mbgLtRefclock 19 }
+
+mbgLtRefPzfModeVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notavailable(0),
+ normalOperation(1),
+ antennaFaulty(2)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current Mode of PZF refclock connected to NTP time server as value"
+ --- " 0: not available"
+ --- " 1: Normal Operation"
+ --- " 2: Antenna Faulty"
+ DEFVAL { 0 }
+ ::= { mbgLtRefclock 20 }
+
+
+mbgLtRefIrigState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current State of IRIG refclock connected to NTP time server "
+ ::= { mbgLtRefclock 21 }
+
+mbgLtRefIrigStateVal OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current State of IRIG refclock connected to NTP time server as value"
+ --- Please refer to manual for IRIG states. They are represented by set/unset bits,
+ --- so this value is a "binary" form combining all possible IRIG states of our IRIG refclock
+ DEFVAL { 0 }
+ ::= { mbgLtRefclock 22 }
+
+mbgLtRefSHSMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current Mode of SHS system connected to NTP time server "
+ ::= { mbgLtRefclock 23 }
+
+mbgLtRefSHSModeVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notavailable(0),
+ normalOperation(1),
+ stoppedTimeLimitError(2)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current Mode of SHS system connected to NTP time server as value"
+ --- " 0: not available"
+ --- " 1: Normal Operation"
+ --- " 2: Stopped/Time Limit Error"
+ DEFVAL { 0 }
+ ::= { mbgLtRefclock 24 }
+
+mbgLtRefSHSTimeDiff OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current time difference between the two SHS reference time sources in miliseconds"
+ DEFVAL { 0 }
+ ::= { mbgLtRefclock 25 }
+
+mbgLtRefDctState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current State of DCF77 refclock connected to NTP time server "
+ ::= { mbgLtRefclock 26 }
+
+mbgLtRefDctStateVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notavailable(0),
+ sync(1),
+ notsyncnow(2),
+ neversynced(3)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current State of DCF77 refclock connected to NTP time server as value"
+ --- " 0: not available"
+ --- " 1: sync"
+ --- " 2: not sync now"
+ --- " 3: never synced"
+ DEFVAL { 0 }
+ ::= { mbgLtRefclock 27 }
+
+mbgLtRefDctField OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current strength of field of DCF77 refclock connected to NTP time server "
+ --- " 0: not available"
+ DEFVAL { "0" }
+ ::= { mbgLtRefclock 28 }
+
+mbgLtRefDctMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current Mode of DCF77 refclock connected to NTP time server "
+ ::= { mbgLtRefclock 29 }
+
+mbgLtRefDctModeVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notavailable(0),
+ normalOperation(1),
+ antennaFaulty(2)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "current Mode of DCF77 refclock connected to NTP time server as value"
+ --- " 0: not available"
+ --- " 1: Normal Operation"
+ --- " 2: Antenna Faulty"
+ DEFVAL { 0 }
+ ::= { mbgLtRefclock 30 }
+
+
+
+mbgLtRefGpsLeapSecond OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Date and Time of leap second announcement received via GPS"
+ ::= { mbgLtRefclock 31 }
+
+mbgLtRefGpsLeapCorrection OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Leap Second Correction received via GPS"
+ --- Possible values are:
+ --- -1 (negative leap second, never happened so far)
+ --- 0 (no leap second announcement received)
+ --- 1 (positive leap second, will be inserted between 23:59:59 on the the leap second date
+ --- and 00:00:00 on the day after the leap second date
+ DEFVAL { 0 }
+ ::= { mbgLtRefclock 32 }
+
+--
+-- MRS (Multi Reference Source) Section
+--
+mbgLtMrs OBJECT IDENTIFIER ::= { mbgLtRefclock 50 }
+
+mbgLtRefMrsRef OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ID of currently active reference source as a string"
+ -- Examples: gps,ntp,irig,pps,frequency,ptp
+
+ ::= { mbgLtMrs 1 }
+
+
+mbgLtRefMrsRefVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notavailable(0),
+ refGps(1),
+ refIrig(2),
+ refPps(3),
+ refFreq(4),
+ refPtp(5),
+ refNtp(6),
+ refFreeRun(99)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "currently active reference as a value"
+ -- 0: not available (no MRS/initializing)
+ -- 1: GPS
+ -- 2: IRIG (Time Code, both DCLS and AM possible)
+ -- 3: PPS (Pulse Per Second)
+ -- 4: Frequency (e.g. 10MHz)
+ -- 5: PTP/IEEE1588 (synchronized by a PTP Grandmaster)
+ -- 6: NTP/Network Time Protocol (synchronized by an NTP server)
+ -- 99: Free running (no sync source, internal oscillator is freewheeling)
+
+ ::= { mbgLtMrs 2 }
+
+
+mbgLtRefMrsRefList OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "List of all supported MRS references in a comma separated list"
+ -- Example: "gps,irig,ntp,ptp,pps,freq"
+
+ ::= { mbgLtMrs 3 }
+
+
+mbgLtRefMrsPrioList OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "List of all active MRS references in a comma separated list sorted by priority"
+ -- Example: "gps,irig,ntp,ptp,pps,freq"
+ -- "active" means that a priority has been assigne to the reference
+
+ ::= { mbgLtMrs 4 }
+
+
+--
+-- MRS Reference Sources Status Section
+--
+mbgLtMrsRef OBJECT IDENTIFIER ::= { mbgLtMrs 10 }
+
+mbgLtMrsRefGps OBJECT IDENTIFIER ::= { mbgLtMrsRef 1 }
+
+mbgLtMrsGpsOffs OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Offset of this reference to the currently active reference, unit included in the string"
+ -- Example : "100.0ns"
+
+ ::= { mbgLtMrsRefGps 1 }
+
+mbgLtMrsGpsOffsVal OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Offset of this reference to the currently active reference, unit see below"
+ -- Example : "100"
+
+ ::= { mbgLtMrsRefGps 2 }
+
+mbgLtMrsGpsOffsBase OBJECT-TYPE
+ SYNTAX INTEGER {
+ baseSeconds(0),
+ baseMiliseconds(3),
+ baseMicroseconds(6),
+ baseNanoseconds(9)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "base of the offset value shown in mbgLtMrsGpsOffsVal"
+ -- In order to calculate the offset in seconds, multiply mbgLtMrsGpsOffsVal with
+ -- 10^(-x) where x is mbgLtMrsGpsOffsBase
+ -- Example:
+ -- mbgLtMrsOffsVal = 65
+ -- mbgLtMrsOffsBase = 9
+ -- Offset is 65*10^(-9) = 0.000000065 Seconds
+
+ ::= { mbgLtMrsRefGps 3 }
+
+
+mbgLtMrsGpsPrio OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the configured priority of this reference"
+
+ ::= { mbgLtMrsRefGps 4 }
+
+
+mbgLtMrsGpsState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the current status of this reference as a string"
+ -- Example: "is Master", "no signal"
+
+ ::= { mbgLtMrsRefGps 5 }
+
+mbgLtMrsGpsStateVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notAvailable(0),
+ notSupported(1),
+ notConnected(2),
+ noSignal(3),
+ hasLocked(4),
+ isAvailable(5),
+ isAccurate(6),
+ isMaster(7)
+
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the current status of this reference as an Integer value"
+
+ -- 0: reference source not available
+ -- 1: not supported in this system
+ -- 2: nothing connected to this input*
+ -- 3: no signal detected*
+ -- 4: reference source has locked to the signal*
+ -- 5: reference is available
+ -- 6: reference is considered valid and accurate*
+ -- 7: reference is the current MRS master
+ -- NOTE:
+ -- States marked with * are not supported by all references
+
+ ::= { mbgLtMrsRefGps 6 }
+
+
+mbgLtMrsGpsPrecision OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Precision Factor of this reference in nanoseconds"
+ -- Example : "100"
+ -- Note: Only positive values allowed
+
+ ::= { mbgLtMrsRefGps 7 }
+
+
+--
+-- IRIG reference source (for both AM and DCLS input interfaces)
+--
+mbgLtMrsRefIrig OBJECT IDENTIFIER ::= { mbgLtMrsRef 2 }
+
+mbgLtMrsIrigOffs OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Offset of this reference to the currently active reference, unit included in the string"
+ -- Example : "100.0ns"
+
+ ::= { mbgLtMrsRefIrig 1 }
+
+mbgLtMrsIrigOffsVal OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Offset of this reference to the currently active reference, unit see below"
+ -- Example : "100"
+
+ ::= { mbgLtMrsRefIrig 2 }
+
+mbgLtMrsIrigOffsBase OBJECT-TYPE
+ SYNTAX INTEGER {
+ baseSeconds(0),
+ baseMiliseconds(3),
+ baseMicroseconds(6),
+ baseNanoseconds(9)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "base of the offset value shown in mbgLtMrsIrigOffsVal"
+ -- In order to calculate the offset in seconds, multiply mbgLtMrsIrigOffsVal with
+ -- 10^(-x) where x is mbgLtMrsIrigOffsBase
+ -- Example:
+ -- mbgLtMrsOffsVal = 65
+ -- mbgLtMrsOffsBase = 9
+ -- Offset is 65*10^(-9) = 0.000000065 Seconds
+
+ ::= { mbgLtMrsRefIrig 3 }
+
+
+mbgLtMrsIrigPrio OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the configured priority of this reference"
+
+ ::= { mbgLtMrsRefIrig 4 }
+
+
+mbgLtMrsIrigState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the current status of this reference as a string"
+ -- Example: "is Master", "no signal"
+
+ ::= { mbgLtMrsRefIrig 5 }
+
+mbgLtMrsIrigStateVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notAvailable(0),
+ notSupported(1),
+ notConnected(2),
+ noSignal(3),
+ hasLocked(4),
+ isAvailable(5),
+ isAccurate(6),
+ isMaster(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the current status of this reference as an Integer value"
+
+ -- 0: reference source not available
+ -- 1: not supported in this system
+ -- 2: nothing connected to this input*
+ -- 3: no signal detected*
+ -- 4: reference source has locked to the signal*
+ -- 5: reference is available
+ -- 6: reference is considered valid and accurate*
+ -- 7: reference is the current MRS master
+ -- NOTE:
+ -- States marked with * are not supported by all references
+
+ ::= { mbgLtMrsRefIrig 6 }
+
+mbgLtMrsIrigCorr OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Correction Value (Fixed Offset) of this reference in nanoseconds"
+ -- Example : "+100"
+
+ ::= { mbgLtMrsRefIrig 7 }
+
+mbgLtMrsIrigOffsLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Offset Limit in nanoseconds, if exceeded this will trigger a notification"
+ -- Example : "100"
+
+ ::= { mbgLtMrsRefIrig 8 }
+
+mbgLtMrsIrigPrecision OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Precision Factor of this reference in nanoseconds"
+ -- Example : "100"
+ -- Note: Only positive values allowed
+
+ ::= { mbgLtMrsRefIrig 9 }
+
+
+--
+-- PPS reference source
+--
+mbgLtMrsRefPps OBJECT IDENTIFIER ::= { mbgLtMrsRef 3 }
+
+mbgLtMrsPpsOffs OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Offset of this reference to the currently active reference, unit included in the string"
+ -- Example : "100.0ns"
+
+ ::= { mbgLtMrsRefPps 1 }
+
+mbgLtMrsPpsOffsVal OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Offset of this reference to the currently active reference, unit see below"
+ -- Example : "100"
+
+ ::= { mbgLtMrsRefPps 2 }
+
+mbgLtMrsPpsOffsBase OBJECT-TYPE
+ SYNTAX INTEGER {
+ baseSeconds(0),
+ baseMiliseconds(3),
+ baseMicroseconds(6),
+ baseNanoseconds(9)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "base of the offset value shown in mbgLtMrsPpsOffsVal"
+ -- In order to calculate the offset in seconds, multiply mbgLtMrsPpsOffsVal with
+ -- 10^(-x) where x is mbgLtMrsPpsOffsBase
+ -- Example:
+ -- mbgLtMrsOffsVal = 65
+ -- mbgLtMrsOffsBase = 9
+ -- Offset is 65*10^(-9) = 0.000000065 Seconds
+
+ ::= { mbgLtMrsRefPps 3 }
+
+
+mbgLtMrsPpsPrio OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the configured priority of this reference"
+
+ ::= { mbgLtMrsRefPps 4 }
+
+
+mbgLtMrsPpsState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the current status of this reference as a string"
+ -- Example: "is Master", "no signal"
+
+ ::= { mbgLtMrsRefPps 5 }
+
+mbgLtMrsPpsStateVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notAvailable(0),
+ notSupported(1),
+ notConnected(2),
+ noSignal(3),
+ hasLocked(4),
+ isAvailable(5),
+ isAccurate(6),
+ isMaster(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the current status of this reference as an Integer value"
+
+ -- 0: reference source not available
+ -- 1: not supported in this system
+ -- 2: nothing connected to this input*
+ -- 3: no signal detected*
+ -- 4: reference source has locked to the signal*
+ -- 5: reference is available
+ -- 6: reference is considered valid and accurate*
+ -- 7: reference is the current MRS master
+ -- NOTE:
+ -- States marked with * are not supported by all references
+
+ ::= { mbgLtMrsRefPps 6 }
+
+
+mbgLtMrsPpsCorr OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Correction Value (Fixed Offset) of this reference in nanoseconds"
+ -- Example : "+100"
+
+ ::= { mbgLtMrsRefPps 7 }
+
+mbgLtMrsPpsOffsLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Offset Limit in nanoseconds, if exceeded this will trigger a notification"
+ -- Example : "100"
+
+ ::= { mbgLtMrsRefPps 8 }
+
+
+mbgLtMrsPpsPrecision OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Precision Factor of this reference in nanoseconds"
+ -- Example : "100"
+ -- Note: Only positive values allowed
+
+ ::= { mbgLtMrsRefPps 9 }
+
+
+--
+-- Frequency reference source (can be 10 MHz or 2048kHz)
+--
+mbgLtMrsRefFreq OBJECT IDENTIFIER ::= { mbgLtMrsRef 4 }
+
+mbgLtMrsFreqOffs OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Offset of this reference to the currently active reference, unit included in the string"
+ -- Example : "100.0ns"
+
+ ::= { mbgLtMrsRefFreq 1 }
+
+mbgLtMrsFreqOffsVal OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Offset of this reference to the currently active reference, unit see below"
+ -- Example : "100"
+
+ ::= { mbgLtMrsRefFreq 2 }
+
+mbgLtMrsFreqOffsBase OBJECT-TYPE
+ SYNTAX INTEGER {
+ baseSeconds(0),
+ baseMiliseconds(3),
+ baseMicroseconds(6),
+ baseNanoseconds(9)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "base of the offset value shown in mbgLtMrsFreqOffsVal"
+ -- In order to calculate the offset in seconds, multiply mbgLtMrsFreqOffsVal with
+ -- 10^(-x) where x is mbgLtMrsFreqOffsBase
+ -- Example:
+ -- mbgLtMrsOffsVal = 65
+ -- mbgLtMrsOffsBase = 9
+ -- Offset is 65*10^(-9) = 0.000000065 Seconds
+
+ ::= { mbgLtMrsRefFreq 3 }
+
+
+mbgLtMrsFreqPrio OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the configured priority of this reference"
+
+ ::= { mbgLtMrsRefFreq 4 }
+
+
+mbgLtMrsFreqState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the current status of this reference as a string"
+ -- Example: "is Master", "no signal"
+
+ ::= { mbgLtMrsRefFreq 5 }
+
+mbgLtMrsFreqStateVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notAvailable(0),
+ notSupported(1),
+ notConnected(2),
+ noSignal(3),
+ hasLocked(4),
+ isAvailable(5),
+ isAccurate(6),
+ isMaster(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the current status of this reference as an Integer value"
+
+ -- 0: reference source not available
+ -- 1: not supported in this system
+ -- 2: nothing connected to this input*
+ -- 3: no signal detected*
+ -- 4: reference source has locked to the signal*
+ -- 5: reference is available
+ -- 6: reference is considered valid and accurate*
+ -- 7: reference is the current MRS master
+ -- NOTE:
+ -- States marked with * are not supported by all references
+
+ ::= { mbgLtMrsRefFreq 6 }
+
+mbgLtMrsFreqCorr OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Correction Value (Fixed Offset) of this reference in nanoseconds"
+ -- Example : "+100"
+
+ ::= { mbgLtMrsRefFreq 7 }
+
+mbgLtMrsFreqOffsLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Offset Limit in nanoseconds, if exceeded this will trigger a notification"
+ -- Example : "100"
+
+ ::= { mbgLtMrsRefFreq 8 }
+
+mbgLtMrsFreqPrecision OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Precision Factor of this reference in nanoseconds"
+ -- Example : "100"
+ -- Note: Only positive values allowed
+
+ ::= { mbgLtMrsRefFreq 9 }
+
+--
+-- PTP/IEEE1588 reference source
+--
+mbgLtMrsRefPtp OBJECT IDENTIFIER ::= { mbgLtMrsRef 5 }
+
+mbgLtMrsPtpOffs OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Offset of this reference to the currently active reference, unit included in the string"
+ -- Example : "100.0ns"
+
+ ::= { mbgLtMrsRefPtp 1 }
+
+mbgLtMrsPtpOffsVal OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Offset of this reference to the currently active reference, unit see below"
+ -- Example : "100"
+
+ ::= { mbgLtMrsRefPtp 2 }
+
+mbgLtMrsPtpOffsBase OBJECT-TYPE
+ SYNTAX INTEGER {
+ baseSeconds(0),
+ baseMiliseconds(3),
+ baseMicroseconds(6),
+ baseNanoseconds(9)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "base of the offset value shown in mbgLtMrsPtpOffsVal"
+ -- In order to calculate the offset in seconds, multiply mbgLtMrsPtpOffsVal with
+ -- 10^(-x) where x is mbgLtMrsPtpOffsBase
+ -- Example:
+ -- mbgLtMrsOffsVal = 65
+ -- mbgLtMrsOffsBase = 9
+ -- Offset is 65*10^(-9) = 0.000000065 Seconds
+
+ ::= { mbgLtMrsRefPtp 3 }
+
+
+mbgLtMrsPtpPrio OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the configured priority of this reference"
+
+ ::= { mbgLtMrsRefPtp 4 }
+
+
+mbgLtMrsPtpState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the current status of this reference as a string"
+ -- Example: "is Master", "no signal"
+
+ ::= { mbgLtMrsRefPtp 5 }
+
+mbgLtMrsPtpStateVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notAvailable(0),
+ notSupported(1),
+ notConnected(2),
+ noSignal(3),
+ hasLocked(4),
+ isAvailable(5),
+ isAccurate(6),
+ isMaster(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the current status of this reference as an Integer value"
+
+ -- 0: reference source not available
+ -- 1: not supported in this system
+ -- 2: nothing connected to this input*
+ -- 3: no signal detected*
+ -- 4: reference source has locked to the signal*
+ -- 5: reference is available
+ -- 6: reference is considered valid and accurate*
+ -- 7: reference is the current MRS master
+ -- NOTE:
+ -- States marked with * are not supported by all references
+
+ ::= { mbgLtMrsRefPtp 6 }
+
+
+mbgLtMrsPtpCorr OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Correction Value (Fixed Offset) of this reference in nanoseconds"
+ -- Example : "+100"
+
+ ::= { mbgLtMrsRefPtp 7 }
+
+mbgLtMrsPtpOffsLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Offset Limit in nanoseconds, if exceeded this will trigger a notification"
+ -- Example : "100"
+
+ ::= { mbgLtMrsRefPtp 8 }
+
+mbgLtMrsPtpPrecision OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Precision Factor of this reference in nanoseconds"
+ -- Example : "100"
+ -- Note: Only positive values allowed
+
+ ::= { mbgLtMrsRefPtp 9 }
+
+--
+-- NTP reference source
+--
+mbgLtMrsRefNtp OBJECT IDENTIFIER ::= { mbgLtMrsRef 6 }
+
+mbgLtMrsNtpOffs OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Offset of this reference to the currently active reference, unit included in the string"
+ -- Example : "100.0ns"
+
+ ::= { mbgLtMrsRefNtp 1 }
+
+mbgLtMrsNtpOffsVal OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Offset of this reference to the currently active reference, unit see below"
+ -- Example : "100"
+
+ ::= { mbgLtMrsRefNtp 2 }
+
+mbgLtMrsNtpOffsBase OBJECT-TYPE
+ SYNTAX INTEGER {
+ baseSeconds(0),
+ baseMiliseconds(3),
+ baseMicroseconds(6),
+ baseNanoseconds(9)
+ }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "base of the offset value shown in mbgLtMrsNtpOffsVal"
+ -- In order to calculate the offset in seconds, multiply mbgLtMrsNtpOffsVal with
+ -- 10^(-x) where x is mbgLtMrsNtpOffsBase
+ -- Example:
+ -- mbgLtMrsOffsVal = 65
+ -- mbgLtMrsOffsBase = 9
+ -- Offset is 65*10^(-9) = 0.000000065 Seconds
+
+ ::= { mbgLtMrsRefNtp 3 }
+
+
+mbgLtMrsNtpPrio OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the configured priority of this reference"
+
+ ::= { mbgLtMrsRefNtp 4 }
+
+
+mbgLtMrsNtpState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the current status of this reference as a string"
+ -- Example: "is Master", "no signal"
+
+ ::= { mbgLtMrsRefNtp 5 }
+
+mbgLtMrsNtpStateVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ notAvailable(0),
+ notSupported(1),
+ notConnected(2),
+ noSignal(3),
+ hasLocked(4),
+ isAvailable(5),
+ isAccurate(6),
+ isMaster(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "the current status of this reference as an Integer value"
+
+ -- 0: reference source not available
+ -- 1: not supported in this system
+ -- 2: nothing connected to this input*
+ -- 3: no signal detected*
+ -- 4: reference source has locked to the signal*
+ -- 5: reference is available
+ -- 6: reference is considered valid and accurate*
+ -- 7: reference is the current MRS master
+ -- NOTE:
+ -- States marked with * are not supported by all references
+
+ ::= { mbgLtMrsRefNtp 6 }
+
+mbgLtMrsNtpCorr OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Correction Value (Fixed Offset) of this reference in nanoseconds"
+ -- Example : "+100"
+
+ ::= { mbgLtMrsRefNtp 7 }
+
+mbgLtMrsNtpOffsLimit OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Offset Limit in nanoseconds, if exceeded this will trigger a notification"
+ -- Example : "100"
+
+ ::= { mbgLtMrsRefNtp 8 }
+
+
+mbgLtMrsNtpPrecision OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Precision Factor of this reference in nanoseconds"
+ -- Example : "100"
+ -- Note: Only positive values allowed
+
+ ::= { mbgLtMrsRefNtp 9 }
+
+--
+-- Lantime SNMP trap definitions
+--
+
+mbgLtNotifications OBJECT IDENTIFIER ::= { mbgLantime 3 }
+mbgLtTraps OBJECT IDENTIFIER ::= { mbgLtNotifications 0 }
+
+
+mbgLtTrapNTPNotSync NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when NTP is not synchronised "
+ ::= { mbgLtTraps 1 }
+
+mbgLtTrapNTPStopped NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when NTP is stopped "
+ ::= { mbgLtTraps 2 }
+
+mbgLtTrapServerBoot NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when time server has finished boot sequence "
+ ::= { mbgLtTraps 3 }
+
+mbgLtTrapReceiverNotResponding NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when receiver is not responding "
+ ::= { mbgLtTraps 4 }
+
+mbgLtTrapReceiverNotSync NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when receiver is not synchronised "
+ ::= { mbgLtTraps 5 }
+
+mbgLtTrapAntennaFaulty NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when connection to antenna is broken "
+ ::= { mbgLtTraps 6 }
+
+mbgLtTrapAntennaReconnect NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when antenna has been reconnected "
+ ::= { mbgLtTraps 7 }
+
+mbgLtTrapConfigChanged NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when timeserver reloaded its configuration "
+ ::= { mbgLtTraps 8 }
+
+mbgLtTrapLeapSecondAnnounced NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when a leap second has been announced "
+ ::= { mbgLtTraps 9 }
+
+mbgLtTrapSHSTimeLimitError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when SHS timelimit exceeded "
+ ::= { mbgLtTraps 10 }
+
+mbgLtTrapSecondaryRecNotSync NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when secondary receiver in SHS system is not synchronised "
+ ::= { mbgLtTraps 11 }
+
+mbgLtTrapPowerSupplyFailure NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when one of the redundant power supplies fails"
+ ::= { mbgLtTraps 12 }
+
+mbgLtTrapAntennaShortCircuit NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when a connected antenna fails due to a short circuit"
+ ::= { mbgLtTraps 13 }
+
+mbgLtTrapReceiverSync NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when receiver is synchronised "
+ ::= { mbgLtTraps 14 }
+
+mbgLtTrapNTPClientAlarm NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when an NTP Client Monitoring alarm occurs, e.g. when a monitored client is not reachable. "
+ ::= { mbgLtTraps 15 }
+
+mbgLtTrapPowerSupplyUp NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when a power supply returned to a healthy state. "
+ ::= { mbgLtTraps 16 }
+
+mbgLtTrapNetworkDown NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when a monitored network port is down. "
+ ::= { mbgLtTraps 17 }
+
+mbgLtTrapNetworkUp NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when a monitored network port is up. "
+ ::= { mbgLtTraps 18 }
+
+mbgLtTrapSecondaryRecNotResp NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when secondary receiver is not responding "
+ ::= { mbgLtTraps 19 }
+
+
+mbgLtTrapXmrLimitExceeded NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when a reference offset exceeds the configured limit"
+ ::= { mbgLtTraps 30 }
+
+mbgLtTrapXmrRefDisconnect NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when a reference signal has been lost"
+ ::= { mbgLtTraps 31 }
+
+
+mbgLtTrapXmrRefReconnect NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when a reference signal recovered"
+ ::= { mbgLtTraps 32 }
+
+mbgLtTrapFdmError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when the Fdm module generates an alarm "
+ ::= { mbgLtTraps 33 }
+
+mbgLtTrapSHSTimeLimitWarning NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when SHS warning limit exceeded "
+ ::= { mbgLtTraps 34 }
+
+mbgLtTrapSecondaryRecSync NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when secondary receiver is synchronised "
+ ::= { mbgLtTraps 35 }
+
+mbgLtTrapNTPSync NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when NTP is synchronised "
+ ::= { mbgLtTraps 36 }
+
+mbgLtTrapPtpPortDisconnected NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when PTP network port got disconnected"
+ ::= { mbgLtTraps 37 }
+
+mbgLtTrapPtpPortConnected NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when PTP network port got connected"
+ ::= { mbgLtTraps 38 }
+
+mbgLtTrapPtpStateChanged NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when PTP state changed (e.g. from 'passive' to 'master')"
+ ::= { mbgLtTraps 39 }
+
+mbgLtTrapPtpError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when PTP raised an error"
+ ::= { mbgLtTraps 40 }
+
+mbgLtTrapNormalOperation NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when the system returned to a healthy state "
+ ::= { mbgLtTraps 77 }
+
+mbgLtTrapHeartbeat NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent periodically to indicate that time server is still alive "
+ ::= { mbgLtTraps 88 }
+
+mbgLtTrapTestNotification NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "trap to be sent when a test notification has been requested "
+ ::= { mbgLtTraps 99 }
+
+mbgLtTrapMessage OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "used as a payload object for all traps, holds a clear text event message"
+ DEFVAL { "no event" }
+ ::= { mbgLtTraps 100 }
+
+--
+-- Meinberg Lantime CFG MIB objects for agent module
+--
+
+
+mbgLtCfg OBJECT IDENTIFIER ::= { mbgLantime 4 }
+
+--
+-- Network parameters
+--
+
+
+mbgLtCfgNetwork OBJECT IDENTIFIER ::= { mbgLtCfg 1 }
+
+mbgLtCfgHostname OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The hostname configured for this LANTIME"
+ ::= { mbgLtCfgNetwork 1 }
+
+mbgLtCfgDomainname OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The domainname configured for this LANTIME"
+ ::= { mbgLtCfgNetwork 2 }
+
+
+mbgLtCfgNameserver1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The first nameserver used by this LANTIME"
+ ::= { mbgLtCfgNetwork 3 }
+
+mbgLtCfgNameserver2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The second nameserver used this LANTIME"
+ ::= { mbgLtCfgNetwork 4 }
+
+mbgLtCfgSyslogserver1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The first syslog server we are sending log entries to"
+ ::= { mbgLtCfgNetwork 5 }
+
+mbgLtCfgSyslogserver2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The second syslog server we are sending log entries to"
+ ::= { mbgLtCfgNetwork 6 }
+
+mbgLtCfgTelnetAccess OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is telnet administration enabled"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNetwork 7 }
+
+mbgLtCfgFTPAccess OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is FTP administration enabled"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNetwork 8 }
+
+mbgLtCfgHTTPAccess OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is web based administration enabled"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNetwork 9 }
+
+mbgLtCfgHTTPSAccess OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is secure web based administration enabled"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNetwork 10 }
+
+mbgLtCfgSNMPAccess OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is SNMP administration enabled"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNetwork 11 }
+
+mbgLtCfgSambaAccess OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is Samba administration enabled"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNetwork 12 }
+
+mbgLtCfgIPv6Access OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is IPv6 support enabled"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNetwork 13 }
+
+mbgLtCfgSSHAccess OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is SSH administration enabled"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNetwork 14 }
+
+
+
+
+--
+-- NTP parameters
+--
+
+
+mbgLtCfgNTP OBJECT IDENTIFIER ::= { mbgLtCfg 2 }
+
+
+mbgLtCfgNTPServer1 OBJECT IDENTIFIER ::= { mbgLtCfgNTP 1 }
+mbgLtCfgNTPServer2 OBJECT IDENTIFIER ::= { mbgLtCfgNTP 2 }
+mbgLtCfgNTPServer3 OBJECT IDENTIFIER ::= { mbgLtCfgNTP 3 }
+mbgLtCfgNTPServer4 OBJECT IDENTIFIER ::= { mbgLtCfgNTP 4 }
+mbgLtCfgNTPServer5 OBJECT IDENTIFIER ::= { mbgLtCfgNTP 5 }
+mbgLtCfgNTPServer6 OBJECT IDENTIFIER ::= { mbgLtCfgNTP 6 }
+mbgLtCfgNTPServer7 OBJECT IDENTIFIER ::= { mbgLtCfgNTP 7 }
+
+mbgLtCfgNTPServer1IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address for external NTP server"
+ ::= { mbgLtCfgNTPServer1 1 }
+
+mbgLtCfgNTPServer1Key OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Key for external NTP server"
+ ::= { mbgLtCfgNTPServer1 2 }
+
+mbgLtCfgNTPServer1Autokey OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is autokey enabled for the external NTP server"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTPServer1 3 }
+
+mbgLtCfgNTPServer1Prefer OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is the preferred flag enabled for the external NTP server"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTPServer1 4 }
+
+
+
+mbgLtCfgNTPServer2IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address for external NTP server"
+ ::= { mbgLtCfgNTPServer2 1 }
+
+mbgLtCfgNTPServer2Key OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Key for external NTP server"
+ ::= { mbgLtCfgNTPServer2 2 }
+
+mbgLtCfgNTPServer2Autokey OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is autokey enabled for the external NTP server"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTPServer2 3 }
+
+mbgLtCfgNTPServer2Prefer OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is the preferred flag enabled for the external NTP server"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTPServer2 4 }
+
+
+
+
+mbgLtCfgNTPServer3IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address for external NTP server"
+ ::= { mbgLtCfgNTPServer3 1 }
+
+mbgLtCfgNTPServer3Key OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Key for external NTP server"
+ ::= { mbgLtCfgNTPServer3 2 }
+
+mbgLtCfgNTPServer3Autokey OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is autokey enabled for the external NTP server"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTPServer3 3 }
+
+mbgLtCfgNTPServer3Prefer OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is the preferred flag enabled for the external NTP server"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTPServer3 4 }
+
+
+
+
+mbgLtCfgNTPServer4IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address for external NTP server"
+ ::= { mbgLtCfgNTPServer4 1 }
+
+mbgLtCfgNTPServer4Key OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Key for external NTP server"
+ ::= { mbgLtCfgNTPServer4 2 }
+
+mbgLtCfgNTPServer4Autokey OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is autokey enabled for the external NTP server"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTPServer4 3 }
+
+mbgLtCfgNTPServer4Prefer OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is the preferred flag enabled for the external NTP server"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTPServer4 4 }
+
+
+
+mbgLtCfgNTPServer5IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address for external NTP server"
+ ::= { mbgLtCfgNTPServer5 1 }
+
+mbgLtCfgNTPServer5Key OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Key for external NTP server"
+ ::= { mbgLtCfgNTPServer5 2 }
+
+mbgLtCfgNTPServer5Autokey OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is autokey enabled for the external NTP server"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTPServer5 3 }
+
+mbgLtCfgNTPServer5Prefer OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is the preferred flag enabled for the external NTP server"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTPServer5 4 }
+
+
+
+
+mbgLtCfgNTPServer6IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address for external NTP server"
+ ::= { mbgLtCfgNTPServer6 1 }
+
+mbgLtCfgNTPServer6Key OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Key for external NTP server"
+ ::= { mbgLtCfgNTPServer6 2 }
+
+mbgLtCfgNTPServer6Autokey OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is autokey enabled for the external NTP server"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTPServer6 3 }
+
+mbgLtCfgNTPServer6Prefer OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is the preferred flag enabled for the external NTP server"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTPServer6 4 }
+
+
+
+mbgLtCfgNTPServer7IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address for external NTP server"
+ ::= { mbgLtCfgNTPServer7 1 }
+
+mbgLtCfgNTPServer7Key OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Key for external NTP server"
+ ::= { mbgLtCfgNTPServer7 2 }
+
+mbgLtCfgNTPServer7Autokey OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is autokey enabled for the external NTP server"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTPServer7 3 }
+
+mbgLtCfgNTPServer7Prefer OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is the preferred flag enabled for the external NTP server"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTPServer7 4 }
+
+
+
+
+
+mbgLtCfgNTPStratumLocalClock OBJECT-TYPE
+ SYNTAX Integer32 (0..15)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The stratum value assigned to the local clock of the timeserver"
+ ::= { mbgLtCfgNTP 8 }
+
+
+mbgLtCfgNTPTrustedKey OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The key used for the internal refclock of the timeserver"
+ ::= { mbgLtCfgNTP 9 }
+
+mbgLtCfgNTPBroadcastIP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "NTP broadcast IP address"
+ ::= { mbgLtCfgNTP 10 }
+
+mbgLtCfgNTPBroadcastKey OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Key used for NTP broadcasts"
+ ::= { mbgLtCfgNTP 11 }
+
+
+mbgLtCfgNTPBroadcastAutokey OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is autokey generation used for NTP broadcasts"
+ ::= { mbgLtCfgNTP 12 }
+
+
+mbgLtCfgNTPAutokeyFeature OBJECT-TYPE
+
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is the NTP autokey feature enabled"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTP 13 }
+
+
+mbgLtCfgNTPAtomPPS OBJECT-TYPE
+
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is the NTP atom pps feature enabled"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgNTP 14 }
+
+
+
+
+--
+-- EMail parameters
+--
+
+
+mbgLtCfgEMail OBJECT IDENTIFIER ::= { mbgLtCfg 3 }
+
+mbgLtCfgEMailTo OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "EMail address to send alerts etc. to (receiving address)"
+ ::= { mbgLtCfgEMail 1 }
+
+mbgLtCfgEMailFrom OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "EMail address to send alerts etc. from (sending address)"
+ ::= { mbgLtCfgEMail 2 }
+
+mbgLtCfgEMailSmarthost OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SMTP smarthost used to send mail"
+ ::= { mbgLtCfgEMail 3 }
+
+
+--
+-- SNMP parameters
+--
+
+
+
+mbgLtCfgSNMP OBJECT IDENTIFIER ::= { mbgLtCfg 4 }
+
+mbgLtCfgSNMPTrapReceiver1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "First SNMP trap receiver host"
+ ::= { mbgLtCfgSNMP 1 }
+
+mbgLtCfgSNMPTrapReceiver2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Second SNMP trap receiver host"
+ ::= { mbgLtCfgSNMP 2 }
+
+mbgLtCfgSNMPTrapRec1Community OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "First SNMP trap receiver community"
+ ::= { mbgLtCfgSNMP 3 }
+
+mbgLtCfgSNMPTrapRec2Community OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Second SNMP trap receiver community"
+ ::= { mbgLtCfgSNMP 4 }
+
+
+mbgLtCfgSNMPReadOnlyCommunity OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SNMP community string for read-only access"
+ ::= { mbgLtCfgSNMP 5 }
+
+
+mbgLtCfgSNMPReadWriteCommunity OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SNMP community string for read-write access"
+ ::= { mbgLtCfgSNMP 6 }
+
+
+mbgLtCfgSNMPContact OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SNMP contact string for Lantime"
+ ::= { mbgLtCfgSNMP 7 }
+
+
+mbgLtCfgSNMPLocation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "SNMP location string for Lantime"
+ ::= { mbgLtCfgSNMP 8 }
+
+
+--
+-- Winpopup parameters
+--
+
+mbgLtCfgWinpopup OBJECT IDENTIFIER ::= { mbgLtCfg 5 }
+
+mbgLtCfgWMailAddress1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "First windows popup alert receiver"
+ ::= { mbgLtCfgWinpopup 1 }
+
+mbgLtCfgWMailAddress2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Second windows popup alert receiver"
+ ::= { mbgLtCfgWinpopup 2 }
+
+
+--
+-- Wallmount display parameters
+--
+
+
+mbgLtCfgWalldisplay OBJECT IDENTIFIER ::= { mbgLtCfg 6 }
+
+mbgLtCfgVP100Display1IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address of first VP100 wall display"
+ ::= { mbgLtCfgWalldisplay 1 }
+
+mbgLtCfgVP100Display1SN OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Serial number of first VP100 wall display"
+ ::= { mbgLtCfgWalldisplay 2 }
+
+mbgLtCfgVP100Display2IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address of second VP100 wall display"
+ ::= { mbgLtCfgWalldisplay 3 }
+
+mbgLtCfgVP100Display2SN OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Serial number of second VP100 wall display"
+ ::= { mbgLtCfgWalldisplay 4 }
+
+
+
+
+--
+-- Notify parameters
+--
+
+
+mbgLtCfgNotify OBJECT IDENTIFIER ::= { mbgLtCfg 7 }
+
+mbgLtCfgNotifyNTPNotSync OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which alerts are sent in case of a NTP_not_sync event"
+ --- possible strings:
+ --- "email (sending an e-mail)"
+ --- "wmail (sending a win popup message)"
+ --- "snmp (sending a SNMP trap)"
+ --- "disp (showing an alert on wall display)"
+ --- "or a comma separated combination of these"
+ --- "An empty string disables notification for this event."
+ --- "Example: wmail,email (sending a win popup and e-mail message)"
+
+ ::= { mbgLtCfgNotify 1 }
+
+mbgLtCfgNotifyNTPStopped OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which alerts are sent in case of a NTP_stopped event"
+ --- possible strings:
+ --- "email (sending an e-mail)"
+ --- "wmail (sending a win popup message)"
+ --- "snmp (sending a SNMP trap)"
+ --- "disp (showing an alert on wall display)"
+ --- "or a comma separated combination of these"
+ --- "An empty string disables notification for this event."
+ --- "Example: wmail,email (sending a win popup and e-mail message)"
+
+ ::= { mbgLtCfgNotify 2 }
+
+mbgLtCfgNotifyServerBoot OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which alerts are sent in case of a server_boot event"
+ --- possible strings:
+ --- "email (sending an e-mail)"
+ --- "wmail (sending a win popup message)"
+ --- "snmp (sending a SNMP trap)"
+ --- "disp (showing an alert on wall display)"
+ --- "or a comma separated combination of these"
+ --- "An empty string disables notification for this event."
+ --- "Example: wmail,email (sending a win popup and e-mail message)"
+
+ ::= { mbgLtCfgNotify 3 }
+
+mbgLtCfgNotifyRefclkNoResponse OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which alerts are sent in case of a refclock_not_responding event"
+ --- possible strings:
+ --- "email (sending an e-mail)"
+ --- "wmail (sending a win popup message)"
+ --- "snmp (sending a SNMP trap)"
+ --- "disp (showing an alert on wall display)"
+ --- "or a comma separated combination of these"
+ --- "An empty string disables notification for this event."
+ --- "Example: wmail,email (sending a win popup and e-mail message)"
+
+ ::= { mbgLtCfgNotify 4 }
+
+mbgLtCfgNotifyRefclockNotSync OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which alerts are sent in case of a refclock_not_sync event"
+ --- possible strings:
+ --- "email (sending an e-mail)"
+ --- "wmail (sending a win popup message)"
+ --- "snmp (sending a SNMP trap)"
+ --- "disp (showing an alert on wall display)"
+ --- "or a comma separated combination of these"
+ --- "An empty string disables notification for this event."
+ --- "Example: wmail,email (sending a win popup and e-mail message)"
+
+ ::= { mbgLtCfgNotify 5 }
+
+mbgLtCfgNotifyAntennaFaulty OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which alerts are sent in case of an antenna_faulty event"
+ --- possible strings:
+ --- "email (sending an e-mail)"
+ --- "wmail (sending a win popup message)"
+ --- "snmp (sending a SNMP trap)"
+ --- "disp (showing an alert on wall display)"
+ --- "or a comma separated combination of these"
+ --- "An empty string disables notification for this event."
+ --- "Example: wmail,email (sending a win popup and e-mail message)"
+
+ ::= { mbgLtCfgNotify 6 }
+
+mbgLtCfgNotifyAntennaReconnect OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which alerts are sent in case of an antenna_reconnect event"
+ --- possible strings:
+ --- "email (sending an e-mail)"
+ --- "wmail (sending a win popup message)"
+ --- "snmp (sending a SNMP trap)"
+ --- "disp (showing an alert on wall display)"
+ --- "or a comma separated combination of these"
+ --- "An empty string disables notification for this event."
+ --- "Example: wmail,email (sending a win popup and e-mail message)"
+
+ ::= { mbgLtCfgNotify 7 }
+
+mbgLtCfgNotifyConfigChanged OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which alerts are sent in case of a config_changed event"
+ --- possible strings:
+ --- "email (sending an e-mail)"
+ --- "wmail (sending a win popup message)"
+ --- "snmp (sending a SNMP trap)"
+ --- "disp (showing an alert on wall display)"
+ --- "or a comma separated combination of these"
+ --- "An empty string disables notification for this event."
+ --- "Example: wmail,email (sending a win popup and e-mail message)"
+
+ ::= { mbgLtCfgNotify 8 }
+
+mbgLtCfgNotifySHSTimeLimitError OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which alerts are sent in case of a SHS_timelimiterror event"
+ --- possible strings:
+ --- "email (sending an e-mail)"
+ --- "wmail (sending a win popup message)"
+ --- "snmp (sending a SNMP trap)"
+ --- "disp (showing an alert on wall display)"
+ --- "or a comma separated combination of these."
+ --- "An empty string disables notification for this event."
+ --- "Example: wmail,email (sending a win popup and e-mail message)"
+
+ ::= { mbgLtCfgNotify 9 }
+
+
+
+mbgLtCfgNotifyLeapSecond OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Which alerts are sent in case of a Leap_Second_Announced event"
+ --- possible strings:
+ --- "email (sending an e-mail)"
+ --- "wmail (sending a win popup message)"
+ --- "snmp (sending a SNMP trap)"
+ --- "disp (showing an alert on wall display)"
+ --- "or a comma separated combination of these."
+ --- "An empty string disables notification for this event."
+ --- "Example: wmail,email (sending a win popup and e-mail message)"
+
+ ::= { mbgLtCfgNotify 10 }
+
+
+
+
+--
+-- Ethernet parameters
+--
+
+
+mbgLtCfgEthernet OBJECT IDENTIFIER ::= { mbgLtCfg 8 }
+
+mbgLtCfgEthernetIf0 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 0 }
+mbgLtCfgEthernetIf1 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 1 }
+mbgLtCfgEthernetIf2 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 2 }
+mbgLtCfgEthernetIf3 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 3 }
+mbgLtCfgEthernetIf4 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 4 }
+mbgLtCfgEthernetIf5 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 5 }
+mbgLtCfgEthernetIf6 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 6 }
+mbgLtCfgEthernetIf7 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 7 }
+mbgLtCfgEthernetIf8 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 8 }
+mbgLtCfgEthernetIf9 OBJECT IDENTIFIER ::= { mbgLtCfgEthernet 9 }
+
+
+
+
+
+mbgLtCfgEthernetIf0IPv4IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 address of the first ethernet interface"
+ ::= { mbgLtCfgEthernetIf0 1 }
+
+mbgLtCfgEthernetIf0IPv4Netmask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 netmask of the first ethernet interface"
+ ::= { mbgLtCfgEthernetIf0 2 }
+
+mbgLtCfgEthernetIf0IPv4Gateway OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 gateway address of the first ethernet interface"
+ ::= { mbgLtCfgEthernetIf0 3 }
+
+
+mbgLtCfgEthernetIf0DHCPClient OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is DHCP used to get IP parameters for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf0 4 }
+
+mbgLtCfgEthernetIf0IPv6IP1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The first IPv6 address of the first ethernet interface"
+ ::= { mbgLtCfgEthernetIf0 5 }
+
+mbgLtCfgEthernetIf0IPv6IP2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The second IPv6 address of the first ethernet interface"
+ ::= { mbgLtCfgEthernetIf0 6 }
+
+mbgLtCfgEthernetIf0IPv6IP3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The third IPv6 address of the first ethernet interface"
+ ::= { mbgLtCfgEthernetIf0 7 }
+
+mbgLtCfgEthernetIf0IPv6Autoconf OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is IPv6 Autoconf used for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf0 8 }
+
+mbgLtCfgEthernetIf0NetLinkMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ autosensing(0),
+ link10half(1),
+ link10full(2),
+ link100half(3),
+ link100full(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Link mode for this interface"
+
+ ::= { mbgLtCfgEthernetIf0 9 }
+
+
+mbgLtCfgEthernetIf1IPv4IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 address of the second ethernet interface"
+ ::= { mbgLtCfgEthernetIf1 1 }
+
+mbgLtCfgEthernetIf1IPv4Netmask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 netmask of the second ethernet interface"
+ ::= { mbgLtCfgEthernetIf1 2 }
+
+mbgLtCfgEthernetIf1IPv4Gateway OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 gateway address of the second ethernet interface"
+ ::= { mbgLtCfgEthernetIf1 3 }
+
+
+mbgLtCfgEthernetIf1DHCPClient OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is DHCP used to get IP parameters for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf1 4 }
+
+mbgLtCfgEthernetIf1IPv6IP1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The first IPv6 address of the second ethernet interface"
+ ::= { mbgLtCfgEthernetIf1 5 }
+
+mbgLtCfgEthernetIf1IPv6IP2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The second IPv6 address of the second ethernet interface"
+ ::= { mbgLtCfgEthernetIf1 6 }
+
+mbgLtCfgEthernetIf1IPv6IP3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The third IPv6 address of the second ethernet interface"
+ ::= { mbgLtCfgEthernetIf1 7 }
+
+mbgLtCfgEthernetIf1IPv6Autoconf OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is IPv6 Autoconf used for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf1 8 }
+
+mbgLtCfgEthernetIf1NetLinkMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ autosensing(0),
+ link10half(1),
+ link10full(2),
+ link100half(3),
+ link100full(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Link mode for this interface"
+
+ ::= { mbgLtCfgEthernetIf1 9 }
+
+
+mbgLtCfgEthernetIf2IPv4IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 address of the third ethernet interface"
+ ::= { mbgLtCfgEthernetIf2 1 }
+
+mbgLtCfgEthernetIf2IPv4Netmask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 netmask of the third ethernet interface"
+ ::= { mbgLtCfgEthernetIf2 2 }
+
+mbgLtCfgEthernetIf2IPv4Gateway OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 gateway address of the third ethernet interface"
+ ::= { mbgLtCfgEthernetIf2 3 }
+
+
+mbgLtCfgEthernetIf2DHCPClient OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is DHCP used to get IP parameters for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf2 4 }
+
+mbgLtCfgEthernetIf2IPv6IP1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The first IPv6 address of the third ethernet interface"
+ ::= { mbgLtCfgEthernetIf2 5 }
+
+mbgLtCfgEthernetIf2IPv6IP2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The second IPv6 address of the third ethernet interface"
+ ::= { mbgLtCfgEthernetIf2 6 }
+
+mbgLtCfgEthernetIf2IPv6IP3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The third IPv6 address of the third ethernet interface"
+ ::= { mbgLtCfgEthernetIf2 7 }
+
+mbgLtCfgEthernetIf2IPv6Autoconf OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is IPv6 Autoconf used for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf2 8 }
+
+mbgLtCfgEthernetIf2NetLinkMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ autosensing(0),
+ link10half(1),
+ link10full(2),
+ link100half(3),
+ link100full(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Link mode for this interface"
+
+ ::= { mbgLtCfgEthernetIf2 9 }
+
+
+mbgLtCfgEthernetIf3IPv4IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 address of the fourth ethernet interface"
+ ::= { mbgLtCfgEthernetIf3 1 }
+
+mbgLtCfgEthernetIf3IPv4Netmask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 netmask of the fourth ethernet interface"
+ ::= { mbgLtCfgEthernetIf3 2 }
+
+mbgLtCfgEthernetIf3IPv4Gateway OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 gateway address of the fourth ethernet interface"
+ ::= { mbgLtCfgEthernetIf3 3 }
+
+
+mbgLtCfgEthernetIf3DHCPClient OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is DHCP used to get IP parameters for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf3 4 }
+
+mbgLtCfgEthernetIf3IPv6IP1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The first IPv6 address of the fourth ethernet interface"
+ ::= { mbgLtCfgEthernetIf3 5 }
+
+mbgLtCfgEthernetIf3IPv6IP2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The second IPv6 address of the fourth ethernet interface"
+ ::= { mbgLtCfgEthernetIf3 6 }
+
+mbgLtCfgEthernetIf3IPv6IP3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The third IPv6 address of the fourth ethernet interface"
+ ::= { mbgLtCfgEthernetIf3 7 }
+
+mbgLtCfgEthernetIf3IPv6Autoconf OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is IPv6 Autoconf used for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf3 8 }
+
+mbgLtCfgEthernetIf3NetLinkMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ autosensing(0),
+ link10half(1),
+ link10full(2),
+ link100half(3),
+ link100full(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Link mode for this interface"
+
+ ::= { mbgLtCfgEthernetIf3 9 }
+
+
+mbgLtCfgEthernetIf4IPv4IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 address of the fifth ethernet interface"
+ ::= { mbgLtCfgEthernetIf4 1 }
+
+mbgLtCfgEthernetIf4IPv4Netmask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 netmask of the fifth ethernet interface"
+ ::= { mbgLtCfgEthernetIf4 2 }
+
+mbgLtCfgEthernetIf4IPv4Gateway OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 gateway address of the fifth ethernet interface"
+ ::= { mbgLtCfgEthernetIf4 3 }
+
+
+mbgLtCfgEthernetIf4DHCPClient OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is DHCP used to get IP parameters for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf4 4 }
+
+mbgLtCfgEthernetIf4IPv6IP1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The first IPv6 address of the fifth ethernet interface"
+ ::= { mbgLtCfgEthernetIf4 5 }
+
+mbgLtCfgEthernetIf4IPv6IP2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The second IPv6 address of the fifth ethernet interface"
+ ::= { mbgLtCfgEthernetIf4 6 }
+
+mbgLtCfgEthernetIf4IPv6IP3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The third IPv6 address of the fifth ethernet interface"
+ ::= { mbgLtCfgEthernetIf4 7 }
+
+mbgLtCfgEthernetIf4IPv6Autoconf OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is IPv6 Autoconf used for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf4 8 }
+
+mbgLtCfgEthernetIf4NetLinkMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ autosensing(0),
+ link10half(1),
+ link10full(2),
+ link100half(3),
+ link100full(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Link mode for this interface"
+
+ ::= { mbgLtCfgEthernetIf4 9 }
+
+
+mbgLtCfgEthernetIf5IPv4IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 address of the sixth ethernet interface"
+ ::= { mbgLtCfgEthernetIf5 1 }
+
+mbgLtCfgEthernetIf5IPv4Netmask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 netmask of the sixth ethernet interface"
+ ::= { mbgLtCfgEthernetIf5 2 }
+
+mbgLtCfgEthernetIf5IPv4Gateway OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 gateway address of the sixth ethernet interface"
+ ::= { mbgLtCfgEthernetIf5 3 }
+
+
+mbgLtCfgEthernetIf5DHCPClient OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is DHCP used to get IP parameters for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf5 4 }
+
+mbgLtCfgEthernetIf5IPv6IP1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The first IPv6 address of the sixth ethernet interface"
+ ::= { mbgLtCfgEthernetIf5 5 }
+
+mbgLtCfgEthernetIf5IPv6IP2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The second IPv6 address of the sixth ethernet interface"
+ ::= { mbgLtCfgEthernetIf5 6 }
+
+mbgLtCfgEthernetIf5IPv6IP3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The third IPv6 address of the sixth ethernet interface"
+ ::= { mbgLtCfgEthernetIf5 7 }
+
+mbgLtCfgEthernetIf5IPv6Autoconf OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is IPv6 Autoconf used for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf5 8 }
+
+mbgLtCfgEthernetIf5NetLinkMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ autosensing(0),
+ link10half(1),
+ link10full(2),
+ link100half(3),
+ link100full(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Link mode for this interface"
+
+ ::= { mbgLtCfgEthernetIf5 9 }
+
+
+mbgLtCfgEthernetIf6IPv4IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 address of the seventh ethernet interface"
+ ::= { mbgLtCfgEthernetIf6 1 }
+
+mbgLtCfgEthernetIf6IPv4Netmask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 netmask of the seventh ethernet interface"
+ ::= { mbgLtCfgEthernetIf6 2 }
+
+mbgLtCfgEthernetIf6IPv4Gateway OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 gateway address of the seventh ethernet interface"
+ ::= { mbgLtCfgEthernetIf6 3 }
+
+
+mbgLtCfgEthernetIf6DHCPClient OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is DHCP used to get IP parameters for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf6 4 }
+
+mbgLtCfgEthernetIf6IPv6IP1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The first IPv6 address of the seventh ethernet interface"
+ ::= { mbgLtCfgEthernetIf6 5 }
+
+mbgLtCfgEthernetIf6IPv6IP2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The second IPv6 address of the seventh ethernet interface"
+ ::= { mbgLtCfgEthernetIf6 6 }
+
+mbgLtCfgEthernetIf6IPv6IP3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The third IPv6 address of the seventh ethernet interface"
+ ::= { mbgLtCfgEthernetIf6 7 }
+
+mbgLtCfgEthernetIf6IPv6Autoconf OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is IPv6 Autoconf used for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf6 8 }
+
+mbgLtCfgEthernetIf6NetLinkMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ autosensing(0),
+ link10half(1),
+ link10full(2),
+ link100half(3),
+ link100full(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Link mode for this interface"
+
+ ::= { mbgLtCfgEthernetIf6 9 }
+
+
+mbgLtCfgEthernetIf7IPv4IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 address of the eighth ethernet interface"
+ ::= { mbgLtCfgEthernetIf7 1 }
+
+mbgLtCfgEthernetIf7IPv4Netmask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 netmask of the eighth ethernet interface"
+ ::= { mbgLtCfgEthernetIf7 2 }
+
+mbgLtCfgEthernetIf7IPv4Gateway OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 gateway address of the eighth ethernet interface"
+ ::= { mbgLtCfgEthernetIf7 3 }
+
+
+mbgLtCfgEthernetIf7DHCPClient OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is DHCP used to get IP parameters for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf7 4 }
+
+mbgLtCfgEthernetIf7IPv6IP1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The first IPv6 address of the eighth ethernet interface"
+ ::= { mbgLtCfgEthernetIf7 5 }
+
+mbgLtCfgEthernetIf7IPv6IP2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The second IPv6 address of the eighth ethernet interface"
+ ::= { mbgLtCfgEthernetIf7 6 }
+
+mbgLtCfgEthernetIf7IPv6IP3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The third IPv6 address of the eighth ethernet interface"
+ ::= { mbgLtCfgEthernetIf7 7 }
+
+mbgLtCfgEthernetIf7IPv6Autoconf OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is IPv6 Autoconf used for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf7 8 }
+
+mbgLtCfgEthernetIf7NetLinkMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ autosensing(0),
+ link10half(1),
+ link10full(2),
+ link100half(3),
+ link100full(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Link mode for this interface"
+
+ ::= { mbgLtCfgEthernetIf7 9 }
+
+
+mbgLtCfgEthernetIf8IPv4IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 address of the nineth ethernet interface"
+ ::= { mbgLtCfgEthernetIf8 1 }
+
+mbgLtCfgEthernetIf8IPv4Netmask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 netmask of the nineth ethernet interface"
+ ::= { mbgLtCfgEthernetIf8 2 }
+
+mbgLtCfgEthernetIf8IPv4Gateway OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 gateway address of the nineth ethernet interface"
+ ::= { mbgLtCfgEthernetIf8 3 }
+
+
+mbgLtCfgEthernetIf8DHCPClient OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is DHCP used to get IP parameters for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf8 4 }
+
+mbgLtCfgEthernetIf8IPv6IP1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The first IPv6 address of the nineth ethernet interface"
+ ::= { mbgLtCfgEthernetIf8 5 }
+
+mbgLtCfgEthernetIf8IPv6IP2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The second IPv6 address of the nineth ethernet interface"
+ ::= { mbgLtCfgEthernetIf8 6 }
+
+mbgLtCfgEthernetIf8IPv6IP3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The third IPv6 address of the nineth ethernet interface"
+ ::= { mbgLtCfgEthernetIf8 7 }
+
+mbgLtCfgEthernetIf8IPv6Autoconf OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is IPv6 Autoconf used for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf8 8 }
+
+mbgLtCfgEthernetIf8NetLinkMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ autosensing(0),
+ link10half(1),
+ link10full(2),
+ link100half(3),
+ link100full(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Link mode for this interface"
+
+ ::= { mbgLtCfgEthernetIf8 9 }
+
+
+mbgLtCfgEthernetIf9IPv4IP OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 address of the tenth ethernet interface"
+ ::= { mbgLtCfgEthernetIf9 1 }
+
+mbgLtCfgEthernetIf9IPv4Netmask OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 netmask of the tenth ethernet interface"
+ ::= { mbgLtCfgEthernetIf9 2 }
+
+mbgLtCfgEthernetIf9IPv4Gateway OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 gateway address of the tenth ethernet interface"
+ ::= { mbgLtCfgEthernetIf9 3 }
+
+
+mbgLtCfgEthernetIf9DHCPClient OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is DHCP used to get IP parameters for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf9 4 }
+
+mbgLtCfgEthernetIf9IPv6IP1 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The first IPv6 address of the tenth ethernet interface"
+ ::= { mbgLtCfgEthernetIf9 5 }
+
+mbgLtCfgEthernetIf9IPv6IP2 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The second IPv6 address of the tenth ethernet interface"
+ ::= { mbgLtCfgEthernetIf9 6 }
+
+mbgLtCfgEthernetIf9IPv6IP3 OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The third IPv6 address of the tenth ethernet interface"
+ ::= { mbgLtCfgEthernetIf9 7 }
+
+mbgLtCfgEthernetIf9IPv6Autoconf OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(0),
+ enabled(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Is IPv6 Autoconf used for this interface"
+ --- "1 = true, 2 = false"
+ ::= { mbgLtCfgEthernetIf9 8 }
+
+mbgLtCfgEthernetIf9NetLinkMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ autosensing(0),
+ link10half(1),
+ link10full(2),
+ link100half(3),
+ link100full(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Link mode for this interface"
+
+ ::= { mbgLtCfgEthernetIf9 9 }
+
+
+--
+-- SHS specific parameters
+--
+
+
+mbgLtCfgSHS OBJECT IDENTIFIER ::= { mbgLtCfg 9 }
+
+
+mbgLtCfgSHSCritLimit OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Max. number of milliseconds the two SHS references can differ before a SHS Critical Timelimit error is issued"
+ ::= { mbgLtCfgSHS 1 }
+
+mbgLtCfgSHSWarnLimit OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Max. number of milliseconds the two SHS references can differ before a SHS Warning Timelimit error is issued"
+ ::= { mbgLtCfgSHS 2 }
+
+
+--
+-- MRS specific parameters
+--
+
+mbgLtCfgMRS OBJECT IDENTIFIER ::= { mbgLtCfg 10 }
+
+mbgLtCfgMRSRefPriority OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Priority of MRS Reference Sources, as a comma-separated list"
+ --- Example: "gps,irig,ntp"
+ --- Possible reference sources are:
+ ::= { mbgLtCfgMRS 1 }
+
+
+
+--
+-- Lantime SNMP commands
+--
+
+mbgLtCmd OBJECT IDENTIFIER ::= { mbgLantime 5 }
+
+mbgLtCmdExecute OBJECT-TYPE
+ SYNTAX INTEGER {
+ ready(0),
+ doReboot(1),
+ doFirmwareUpdate (2),
+ doReloadConfig (3),
+ doGenerateSSHKey (4),
+ doGenerateHTTPSKey (5),
+ doResetFactoryDefaults (6),
+ doGenerateNewNTPAutokeyCert (7),
+ doSendTestNotification (8),
+ doResetSHSTimeLimitError (9)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Send a command to the timeserver to be executed"
+
+ ::={ mbgLtCmd 1 }
+
+mbgLtCmdSetRefTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Set the time of the reference clock and the LANTIME itself"
+ -- The new time has to be specified in UTC time and
+ -- can be either written as a valid ISO8601 date and time string
+ -- e.g. 2006-08-23 16:05:30 (=08/23/2006, 4:05:30pm)
+ -- or a simple number representing the number of seconds
+ -- since 01/01/1970
+
+ ::={ mbgLtCmd 2 }
+
+
+
+mbgLtPtp OBJECT IDENTIFIER ::= { mbgLantime 10 }
+
+
+mbgLtPtpMode OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Display current PTPv2 modus as string"
+ ::= { mbgLtPtp 1 }
+
+
+mbgLtPtpModeVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ stopped (0),
+ master (1),
+ slave (2),
+ ordinary (3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Display current PTPv2 modus as integer"
+ ::= { mbgLtPtp 2 }
+
+
+mbgLtPtpPortState OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current PTPv2 port state as string"
+ ::= { mbgLtPtp 3 }
+
+
+mbgLtPtpPortStateVal OBJECT-TYPE
+ SYNTAX INTEGER {
+ uncalibrated (0),
+ initializing (1),
+ listening (2),
+ master (3),
+ slave (4),
+ unicastmaster (5),
+ unicastslave (6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current PTPv2 port state as integer"
+ ::= { mbgLtPtp 4 }
+
+
+mbgLtPtpOffsetFromGM OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current PTPv2 offset from grandmaster as string"
+ ::= { mbgLtPtp 5 }
+
+
+mbgLtPtpOffsetFromGMVal OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ UNITS "ns"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current PTPv2 offset from grandmaster in nanoseconds"
+ ::= { mbgLtPtp 6 }
+
+
+mbgLtPtpDelay OBJECT-TYPE
+ SYNTAX DisplayString
+ UNITS "ns"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "shows the current network delay in nanoseconds as string"
+ ::= { mbgLtPtp 7 }
+
+
+mbgLtPtpDelayVal OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ UNITS "ns"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "shows the current network delay in nanoseconds"
+ ::= { mbgLtPtp 8 }
+
+
+
+
+--
+-- FDM Powerline Frequency Deviation Monitor Module
+--
+
+mbgLtFdm OBJECT IDENTIFIER ::= { mbgLantime 11 }
+
+mbgLtFdmPlFreq OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "shows the current powerline frequency in mHz as an Integer32 value"
+ ::= { mbgLtFdm 1 }
+
+mbgLtFdmFreqDev OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "shows the current frequency deviation in mHz as an Integer32 value"
+ ::= { mbgLtFdm 2 }
+
+mbgLtFdmNomFreq OBJECT-TYPE
+ SYNTAX Integer32 (-2147483648..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "shows the nominal frequency in mHz as an Integer32 value"
+ -- can be 50000 (50Hz) or 60000 (60Hz)
+ ::= { mbgLtFdm 3 }
+
+
+
+
+
+mbgLtConformance OBJECT IDENTIFIER ::= { mbgLantime 90 }
+mbgLtCompliances OBJECT IDENTIFIER ::= { mbgLtConformance 1 }
+mbgLtGroups OBJECT IDENTIFIER ::= { mbgLtConformance 2 }
+
+mbgLtCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities which implement version 2
+ of the LANTIME MIB"
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ mbgLtObjectsGroup,
+ mbgLtTrapsGroup
+ }
+ ::= { mbgLtCompliances 1 }
+
+
+mbgLtObjectsGroup OBJECT-GROUP
+ OBJECTS {
+ mbgLtFirmwareVersion,
+ mbgLtFirmwareVersionVal,
+ mbgLtNtpCurrentState,
+ mbgLtNtpCurrentStateVal,
+ mbgLtNtpStratum,
+ mbgLtNtpActiveRefclockId,
+ mbgLtNtpActiveRefclockName,
+ mbgLtNtpActiveRefclockOffset,
+ mbgLtNtpActiveRefclockOffsetVal,
+ mbgLtNtpNumberOfRefclocks,
+ mbgLtNtpAuthKeyId,
+ mbgLtNtpVersion,
+ mbgLtRefClockType,
+ mbgLtRefClockTypeVal,
+ mbgLtRefClockMode,
+ mbgLtRefClockModeVal,
+ mbgLtRefGpsState,
+ mbgLtRefGpsStateVal,
+ mbgLtRefGpsPosition,
+ mbgLtRefGpsSatellites,
+ mbgLtRefGpsSatellitesGood,
+ mbgLtRefGpsSatellitesInView,
+ mbgLtRefPzfState,
+ mbgLtRefPzfStateVal,
+ mbgLtRefPzfKorrelation,
+ mbgLtRefPzfField,
+ mbgLtRefGpsMode,
+ mbgLtRefGpsModeVal,
+ mbgLtRefIrigMode,
+ mbgLtRefIrigModeVal,
+ mbgLtRefPzfMode,
+ mbgLtRefPzfModeVal,
+ mbgLtRefIrigState,
+ mbgLtRefIrigStateVal,
+ mbgLtRefSHSMode,
+ mbgLtRefSHSModeVal,
+ mbgLtRefSHSTimeDiff,
+ mbgLtRefDctState,
+ mbgLtRefDctStateVal,
+ mbgLtRefDctField,
+ mbgLtRefDctMode,
+ mbgLtRefDctModeVal,
+ mbgLtRefGpsLeapSecond,
+ mbgLtRefGpsLeapCorrection,
+ mbgLtRefMrsRef,
+ mbgLtRefMrsRefVal,
+ mbgLtRefMrsRefList,
+ mbgLtRefMrsPrioList,
+ mbgLtMrsGpsOffs,
+ mbgLtMrsGpsOffsVal,
+ mbgLtMrsGpsOffsBase,
+ mbgLtMrsGpsPrio,
+ mbgLtMrsGpsState,
+ mbgLtMrsGpsStateVal,
+ mbgLtMrsGpsPrecision,
+ mbgLtMrsIrigOffs,
+ mbgLtMrsIrigOffsVal,
+ mbgLtMrsIrigOffsBase,
+ mbgLtMrsIrigPrio,
+ mbgLtMrsIrigState,
+ mbgLtMrsIrigStateVal,
+ mbgLtMrsIrigCorr,
+ mbgLtMrsIrigOffsLimit,
+ mbgLtMrsIrigPrecision,
+ mbgLtMrsPpsOffs,
+ mbgLtMrsPpsOffsVal,
+ mbgLtMrsPpsOffsBase,
+ mbgLtMrsPpsPrio,
+ mbgLtMrsPpsState,
+ mbgLtMrsPpsStateVal,
+ mbgLtMrsPpsCorr,
+ mbgLtMrsPpsOffsLimit,
+ mbgLtMrsPpsPrecision,
+ mbgLtMrsFreqOffs,
+ mbgLtMrsFreqOffsVal,
+ mbgLtMrsFreqOffsBase,
+ mbgLtMrsFreqPrio,
+ mbgLtMrsFreqState,
+ mbgLtMrsFreqStateVal,
+ mbgLtMrsFreqCorr,
+ mbgLtMrsFreqOffsLimit,
+ mbgLtMrsFreqPrecision,
+ mbgLtMrsPtpOffs,
+ mbgLtMrsPtpOffsVal,
+ mbgLtMrsPtpOffsBase,
+ mbgLtMrsPtpPrio,
+ mbgLtMrsPtpState,
+ mbgLtMrsPtpStateVal,
+ mbgLtMrsPtpCorr,
+ mbgLtMrsPtpOffsLimit,
+ mbgLtMrsPtpPrecision,
+ mbgLtMrsNtpOffs,
+ mbgLtMrsNtpOffsVal,
+ mbgLtMrsNtpOffsBase,
+ mbgLtMrsNtpPrio,
+ mbgLtMrsNtpState,
+ mbgLtMrsNtpStateVal,
+ mbgLtMrsNtpCorr,
+ mbgLtMrsNtpOffsLimit,
+ mbgLtMrsNtpPrecision,
+ mbgLtTrapMessage,
+ mbgLtCfgHostname,
+ mbgLtCfgDomainname,
+ mbgLtCfgNameserver1,
+ mbgLtCfgNameserver2,
+ mbgLtCfgSyslogserver1,
+ mbgLtCfgSyslogserver2,
+ mbgLtCfgTelnetAccess,
+ mbgLtCfgFTPAccess,
+ mbgLtCfgHTTPAccess,
+ mbgLtCfgHTTPSAccess,
+ mbgLtCfgSNMPAccess,
+ mbgLtCfgSambaAccess,
+ mbgLtCfgIPv6Access,
+ mbgLtCfgSSHAccess,
+ mbgLtCfgNTPServer1IP,
+ mbgLtCfgNTPServer1Key,
+ mbgLtCfgNTPServer1Autokey,
+ mbgLtCfgNTPServer1Prefer,
+ mbgLtCfgNTPServer2IP,
+ mbgLtCfgNTPServer2Key,
+ mbgLtCfgNTPServer2Autokey,
+ mbgLtCfgNTPServer2Prefer,
+ mbgLtCfgNTPServer3IP,
+ mbgLtCfgNTPServer3Key,
+ mbgLtCfgNTPServer3Autokey,
+ mbgLtCfgNTPServer3Prefer,
+ mbgLtCfgNTPServer4IP,
+ mbgLtCfgNTPServer4Key,
+ mbgLtCfgNTPServer4Autokey,
+ mbgLtCfgNTPServer4Prefer,
+ mbgLtCfgNTPServer5IP,
+ mbgLtCfgNTPServer5Key,
+ mbgLtCfgNTPServer5Autokey,
+ mbgLtCfgNTPServer5Prefer,
+ mbgLtCfgNTPServer6IP,
+ mbgLtCfgNTPServer6Key,
+ mbgLtCfgNTPServer6Autokey,
+ mbgLtCfgNTPServer6Prefer,
+ mbgLtCfgNTPServer7IP,
+ mbgLtCfgNTPServer7Key,
+ mbgLtCfgNTPServer7Autokey,
+ mbgLtCfgNTPServer7Prefer,
+ mbgLtCfgNTPStratumLocalClock,
+ mbgLtCfgNTPTrustedKey,
+ mbgLtCfgNTPBroadcastIP,
+ mbgLtCfgNTPBroadcastKey,
+ mbgLtCfgNTPBroadcastAutokey,
+ mbgLtCfgNTPAutokeyFeature,
+ mbgLtCfgNTPAtomPPS,
+ mbgLtCfgEMailTo,
+ mbgLtCfgEMailFrom,
+ mbgLtCfgEMailSmarthost,
+ mbgLtCfgSNMPTrapReceiver1,
+ mbgLtCfgSNMPTrapReceiver2,
+ mbgLtCfgSNMPTrapRec1Community,
+ mbgLtCfgSNMPTrapRec2Community,
+ mbgLtCfgSNMPReadOnlyCommunity,
+ mbgLtCfgSNMPReadWriteCommunity,
+ mbgLtCfgSNMPContact,
+ mbgLtCfgSNMPLocation,
+ mbgLtCfgWMailAddress1,
+ mbgLtCfgWMailAddress2,
+ mbgLtCfgVP100Display1IP,
+ mbgLtCfgVP100Display1SN,
+ mbgLtCfgVP100Display2IP,
+ mbgLtCfgVP100Display2SN,
+ mbgLtCfgNotifyNTPNotSync,
+ mbgLtCfgNotifyNTPStopped,
+ mbgLtCfgNotifyServerBoot,
+ mbgLtCfgNotifyRefclkNoResponse,
+ mbgLtCfgNotifyRefclockNotSync,
+ mbgLtCfgNotifyAntennaFaulty,
+ mbgLtCfgNotifyAntennaReconnect,
+ mbgLtCfgNotifyConfigChanged,
+ mbgLtCfgNotifySHSTimeLimitError,
+ mbgLtCfgNotifyLeapSecond,
+ mbgLtCfgEthernetIf0IPv4IP,
+ mbgLtCfgEthernetIf0IPv4Netmask,
+ mbgLtCfgEthernetIf0IPv4Gateway,
+ mbgLtCfgEthernetIf0DHCPClient,
+ mbgLtCfgEthernetIf0IPv6IP1,
+ mbgLtCfgEthernetIf0IPv6IP2,
+ mbgLtCfgEthernetIf0IPv6IP3,
+ mbgLtCfgEthernetIf0IPv6Autoconf,
+
+ mbgLtCfgEthernetIf0NetLinkMode,
+ mbgLtCfgEthernetIf1IPv4IP,
+ mbgLtCfgEthernetIf1IPv4Netmask,
+ mbgLtCfgEthernetIf1IPv4Gateway,
+ mbgLtCfgEthernetIf1DHCPClient,
+ mbgLtCfgEthernetIf1IPv6IP1,
+ mbgLtCfgEthernetIf1IPv6IP2,
+ mbgLtCfgEthernetIf1IPv6IP3,
+ mbgLtCfgEthernetIf1IPv6Autoconf,
+ mbgLtCfgEthernetIf1NetLinkMode,
+ mbgLtCfgEthernetIf2IPv4IP,
+ mbgLtCfgEthernetIf2IPv4Netmask,
+ mbgLtCfgEthernetIf2IPv4Gateway,
+ mbgLtCfgEthernetIf2DHCPClient,
+ mbgLtCfgEthernetIf2IPv6IP1,
+ mbgLtCfgEthernetIf2IPv6IP2,
+ mbgLtCfgEthernetIf2IPv6IP3,
+ mbgLtCfgEthernetIf2IPv6Autoconf,
+ mbgLtCfgEthernetIf2NetLinkMode,
+ mbgLtCfgEthernetIf3IPv4IP,
+ mbgLtCfgEthernetIf3IPv4Netmask,
+ mbgLtCfgEthernetIf3IPv4Gateway,
+ mbgLtCfgEthernetIf3DHCPClient,
+ mbgLtCfgEthernetIf3IPv6IP1,
+ mbgLtCfgEthernetIf3IPv6IP2,
+ mbgLtCfgEthernetIf3IPv6IP3,
+ mbgLtCfgEthernetIf3IPv6Autoconf,
+ mbgLtCfgEthernetIf3NetLinkMode,
+ mbgLtCfgEthernetIf4IPv4IP,
+ mbgLtCfgEthernetIf4IPv4Netmask,
+ mbgLtCfgEthernetIf4IPv4Gateway,
+ mbgLtCfgEthernetIf4DHCPClient,
+ mbgLtCfgEthernetIf4IPv6IP1,
+ mbgLtCfgEthernetIf4IPv6IP2,
+ mbgLtCfgEthernetIf4IPv6IP3,
+ mbgLtCfgEthernetIf4IPv6Autoconf,
+ mbgLtCfgEthernetIf4NetLinkMode,
+ mbgLtCfgEthernetIf5IPv4IP,
+ mbgLtCfgEthernetIf5IPv4Netmask,
+ mbgLtCfgEthernetIf5IPv4Gateway,
+ mbgLtCfgEthernetIf5DHCPClient,
+ mbgLtCfgEthernetIf5IPv6IP1,
+ mbgLtCfgEthernetIf5IPv6IP2,
+ mbgLtCfgEthernetIf5IPv6IP3,
+ mbgLtCfgEthernetIf5IPv6Autoconf,
+ mbgLtCfgEthernetIf5NetLinkMode,
+ mbgLtCfgEthernetIf6IPv4IP,
+ mbgLtCfgEthernetIf6IPv4Netmask,
+ mbgLtCfgEthernetIf6IPv4Gateway,
+ mbgLtCfgEthernetIf6DHCPClient,
+ mbgLtCfgEthernetIf6IPv6IP1,
+ mbgLtCfgEthernetIf6IPv6IP2,
+ mbgLtCfgEthernetIf6IPv6IP3,
+ mbgLtCfgEthernetIf6IPv6Autoconf,
+ mbgLtCfgEthernetIf6NetLinkMode,
+ mbgLtCfgEthernetIf7IPv4IP,
+ mbgLtCfgEthernetIf7IPv4Netmask,
+ mbgLtCfgEthernetIf7IPv4Gateway,
+ mbgLtCfgEthernetIf7DHCPClient,
+ mbgLtCfgEthernetIf7IPv6IP1,
+ mbgLtCfgEthernetIf7IPv6IP2,
+ mbgLtCfgEthernetIf7IPv6IP3,
+ mbgLtCfgEthernetIf7IPv6Autoconf,
+ mbgLtCfgEthernetIf7NetLinkMode,
+ mbgLtCfgEthernetIf8IPv4IP,
+ mbgLtCfgEthernetIf8IPv4Netmask,
+ mbgLtCfgEthernetIf8IPv4Gateway,
+ mbgLtCfgEthernetIf8DHCPClient,
+ mbgLtCfgEthernetIf8IPv6IP1,
+ mbgLtCfgEthernetIf8IPv6IP2,
+ mbgLtCfgEthernetIf8IPv6IP3,
+ mbgLtCfgEthernetIf8IPv6Autoconf,
+ mbgLtCfgEthernetIf8NetLinkMode,
+ mbgLtCfgEthernetIf9IPv4IP,
+ mbgLtCfgEthernetIf9IPv4Netmask,
+ mbgLtCfgEthernetIf9IPv4Gateway,
+ mbgLtCfgEthernetIf9DHCPClient,
+ mbgLtCfgEthernetIf9IPv6IP1,
+ mbgLtCfgEthernetIf9IPv6IP2,
+ mbgLtCfgEthernetIf9IPv6IP3,
+ mbgLtCfgEthernetIf9IPv6Autoconf,
+ mbgLtCfgEthernetIf9NetLinkMode,
+ mbgLtCfgSHSCritLimit,
+ mbgLtCfgSHSWarnLimit,
+ mbgLtCfgMRSRefPriority,
+ mbgLtCmdExecute,
+ mbgLtCmdSetRefTime,
+ mbgLtFdmPlFreq,
+ mbgLtFdmFreqDev,
+ mbgLtFdmNomFreq,
+ mbgLtPtpMode,
+ mbgLtPtpModeVal,
+ mbgLtPtpPortState,
+ mbgLtPtpPortStateVal,
+ mbgLtPtpOffsetFromGM,
+ mbgLtPtpOffsetFromGMVal,
+ mbgLtPtpDelay,
+ mbgLtPtpDelayVal
+ }
+ STATUS current
+ DESCRIPTION
+ "The collection of objects for the LANTIME MIB"
+ ::= { mbgLtGroups 1 }
+
+mbgLtTrapsGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ mbgLtTrapNTPNotSync,
+ mbgLtTrapNTPStopped,
+ mbgLtTrapServerBoot,
+ mbgLtTrapReceiverNotResponding,
+ mbgLtTrapReceiverNotSync,
+ mbgLtTrapAntennaFaulty,
+ mbgLtTrapAntennaReconnect,
+ mbgLtTrapConfigChanged,
+ mbgLtTrapLeapSecondAnnounced,
+ mbgLtTrapSHSTimeLimitError,
+ mbgLtTrapSecondaryRecNotSync,
+ mbgLtTrapPowerSupplyFailure,
+ mbgLtTrapAntennaShortCircuit,
+ mbgLtTrapReceiverSync,
+ mbgLtTrapNTPClientAlarm,
+ mbgLtTrapPowerSupplyUp,
+ mbgLtTrapNetworkDown,
+ mbgLtTrapNetworkUp,
+ mbgLtTrapSecondaryRecNotResp,
+ mbgLtTrapXmrLimitExceeded,
+ mbgLtTrapXmrRefDisconnect,
+ mbgLtTrapXmrRefReconnect,
+ mbgLtTrapFdmError,
+ mbgLtTrapSHSTimeLimitWarning,
+ mbgLtTrapSecondaryRecSync,
+ mbgLtTrapNTPSync,
+ mbgLtTrapNormalOperation,
+ mbgLtTrapHeartbeat,
+ mbgLtTrapTestNotification,
+ mbgLtTrapPtpPortDisconnected,
+ mbgLtTrapPtpPortConnected,
+ mbgLtTrapPtpStateChanged,
+ mbgLtTrapPtpError
+ }
+ STATUS current
+ DESCRIPTION
+ "The collection of traps for the LANTIME MIB"
+ ::= { mbgLtGroups 2 }
+
+END