+RS-232-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, transmission,
+ Counter32, Integer32
+ FROM SNMPv2-SMI
+ InterfaceIndex
+ FROM IF-MIB
+ MODULE-COMPLIANCE, OBJECT-GROUP
+ FROM SNMPv2-CONF;
+
+
+rs232 MODULE-IDENTITY
+ LAST-UPDATED "9405261700Z"
+ ORGANIZATION "IETF Character MIB Working Group"
+ CONTACT-INFO
+ " Bob Stewart
+ Postal: Xyplex, Inc.
+ 295 Foster Street
+ Littleton, MA 01460
+
+ Tel: 508-952-4816
+ Fax: 508-952-4887
+ E-mail: rlstewart@eng.xyplex.com"
+ DESCRIPTION
+ "The MIB module for RS-232-like hardware devices."
+ ::= { transmission 33 }
+
+
+-- Generic RS-232-like information
+
+rs232Number OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of ports (regardless of their current
+ state) in the RS-232-like general port table."
+ ::= { rs232 1 }
+
+
+-- RS-232-like General Port Table
+
+rs232PortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Rs232PortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of port entries. The number of entries is
+ given by the value of rs232Number."
+ ::= { rs232 2 }
+
+rs232PortEntry OBJECT-TYPE
+ SYNTAX Rs232PortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Status and parameter values for a port."
+ INDEX { rs232PortIndex }
+ ::= { rs232PortTable 1 }
+
+Rs232PortEntry ::=
+ SEQUENCE {
+ rs232PortIndex
+ InterfaceIndex,
+ rs232PortType
+ INTEGER,
+ rs232PortInSigNumber
+ Integer32,
+ rs232PortOutSigNumber
+ Integer32,
+ rs232PortInSpeed
+ Integer32,
+ rs232PortOutSpeed
+ Integer32,
+ rs232PortInFlowType
+ INTEGER,
+ rs232PortOutFlowType
+ INTEGER
+ }
+
+rs232PortIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of ifIndex for the port. By convention
+ and if possible, hardware port numbers map directly
+ to external connectors. The value for each port must
+ remain constant at least from one re-initialization
+ of the network management agent to the next."
+ ::= { rs232PortEntry 1 }
+
+rs232PortType OBJECT-TYPE
+ SYNTAX INTEGER { other(1), rs232(2), rs422(3),
+ rs423(4), v35(5), x21(6) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port's hardware type."
+ ::= { rs232PortEntry 2 }
+
+rs232PortInSigNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of input signals for the port in the
+ input signal table (rs232PortInSigTable). The table
+ contains entries only for those signals the software
+ can detect and that are useful to observe."
+ ::= { rs232PortEntry 3 }
+
+rs232PortOutSigNumber OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of output signals for the port in the
+ output signal table (rs232PortOutSigTable). The
+ table contains entries only for those signals the
+ software can assert and that are useful to observe."
+ ::= { rs232PortEntry 4 }
+
+rs232PortInSpeed OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The port's input speed in bits per second. Note that
+ non-standard values, such as 9612, are probably not allowed
+ on most implementations."
+ ::= { rs232PortEntry 5 }
+
+rs232PortOutSpeed OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The port's output speed in bits per second. Note that
+ non-standard values, such as 9612, are probably not allowed
+ on most implementations."
+ ::= { rs232PortEntry 6 }
+
+rs232PortInFlowType OBJECT-TYPE
+ SYNTAX INTEGER { none(1), ctsRts(2), dsrDtr(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The port's type of input flow control. 'none'
+ indicates no flow control at this level.
+ 'ctsRts' and 'dsrDtr' indicate use of the indicated
+ hardware signals."
+ ::= { rs232PortEntry 7 }
+
+rs232PortOutFlowType OBJECT-TYPE
+ SYNTAX INTEGER { none(1), ctsRts(2), dsrDtr(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The port's type of output flow control. 'none'
+ indicates no flow control at this level.
+ 'ctsRts' and 'dsrDtr' indicate use of the indicated
+ hardware signals."
+ ::= { rs232PortEntry 8 }
+
+
+-- RS-232-like Asynchronous Port Table
+
+rs232AsyncPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Rs232AsyncPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of asynchronous port entries. Entries need
+ not exist for synchronous ports."
+ ::= { rs232 3 }
+
+rs232AsyncPortEntry OBJECT-TYPE
+ SYNTAX Rs232AsyncPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Status and parameter values for an asynchronous
+ port."
+ INDEX { rs232AsyncPortIndex }
+ ::= { rs232AsyncPortTable 1 }
+
+Rs232AsyncPortEntry ::=
+ SEQUENCE {
+ rs232AsyncPortIndex
+ InterfaceIndex,
+ rs232AsyncPortBits
+ INTEGER,
+ rs232AsyncPortStopBits
+ INTEGER,
+ rs232AsyncPortParity
+ INTEGER,
+ rs232AsyncPortAutobaud
+ INTEGER,
+ rs232AsyncPortParityErrs
+ Counter32,
+ rs232AsyncPortFramingErrs
+ Counter32,
+ rs232AsyncPortOverrunErrs
+ Counter32
+
+ }
+
+rs232AsyncPortIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value for each port. Its value is the
+ same as rs232PortIndex for the port."
+ ::= { rs232AsyncPortEntry 1 }
+
+rs232AsyncPortBits OBJECT-TYPE
+ SYNTAX INTEGER (5..8)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The port's number of bits in a character."
+ ::= { rs232AsyncPortEntry 2 }
+
+rs232AsyncPortStopBits OBJECT-TYPE
+ SYNTAX INTEGER { one(1), two(2),
+ oneAndHalf(3), dynamic(4) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The port's number of stop bits."
+ ::= { rs232AsyncPortEntry 3 }
+
+rs232AsyncPortParity OBJECT-TYPE
+ SYNTAX INTEGER { none(1), odd(2), even(3),
+ mark(4), space(5) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The port's sense of a character parity bit."
+ ::= { rs232AsyncPortEntry 4 }
+
+rs232AsyncPortAutobaud OBJECT-TYPE
+ SYNTAX INTEGER { enabled(1), disabled(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A control for the port's ability to automatically
+ sense input speed.
+
+ When rs232PortAutoBaud is 'enabled', a port may
+ autobaud to values different from the set values for
+ speed, parity, and character size. As a result a
+ network management system may temporarily observe
+ values different from what was previously set."
+ ::= { rs232AsyncPortEntry 5 }
+
+rs232AsyncPortParityErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of characters with a parity error,
+ input from the port since system re-initialization
+ and while the port state was 'up' or 'test'."
+ ::= { rs232AsyncPortEntry 6 }
+
+rs232AsyncPortFramingErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of characters with a framing error,
+ input from the port since system re-initialization
+ and while the port state was 'up' or 'test'."
+ ::= { rs232AsyncPortEntry 7 }
+
+rs232AsyncPortOverrunErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of characters with an overrun error,
+ input from the port since system re-initialization
+ and while the port state was 'up' or 'test'."
+ ::= { rs232AsyncPortEntry 8 }
+
+
+-- RS-232-like Synchronous Port Table
+
+rs232SyncPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Rs232SyncPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of asynchronous port entries. Entries need
+ not exist for synchronous ports."
+ ::= { rs232 4 }
+
+rs232SyncPortEntry OBJECT-TYPE
+ SYNTAX Rs232SyncPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Status and parameter values for a synchronous
+ port."
+ INDEX { rs232SyncPortIndex }
+ ::= { rs232SyncPortTable 1 }
+
+Rs232SyncPortEntry ::=
+ SEQUENCE {
+ rs232SyncPortIndex
+ InterfaceIndex,
+ rs232SyncPortClockSource
+ INTEGER,
+ rs232SyncPortFrameCheckErrs
+ Counter32,
+ rs232SyncPortTransmitUnderrunErrs
+ Counter32,
+ rs232SyncPortReceiveOverrunErrs
+ Counter32,
+ rs232SyncPortInterruptedFrames
+ Counter32,
+ rs232SyncPortAbortedFrames
+ Counter32,
+ rs232SyncPortRole
+ INTEGER,
+ rs232SyncPortEncoding
+ INTEGER,
+ rs232SyncPortRTSControl
+ INTEGER,
+ rs232SyncPortRTSCTSDelay
+ Integer32,
+ rs232SyncPortMode
+ INTEGER,
+ rs232SyncPortIdlePattern
+ INTEGER,
+ rs232SyncPortMinFlags
+ Integer32
+ }
+
+rs232SyncPortIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value for each port. Its value is the
+ same as rs232PortIndex for the port."
+ ::= { rs232SyncPortEntry 1 }
+
+rs232SyncPortClockSource OBJECT-TYPE
+ SYNTAX INTEGER { internal(1), external(2), split(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Source of the port's bit rate clock. 'split' means
+ the tranmit clock is internal and the receive clock
+ is external."
+ ::= { rs232SyncPortEntry 2 }
+
+rs232SyncPortFrameCheckErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of frames with an invalid frame check
+ sequence, input from the port since system
+ re-initialization and while the port state was 'up'
+ or 'test'."
+ ::= { rs232SyncPortEntry 3 }
+
+rs232SyncPortTransmitUnderrunErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of frames that failed to be
+ transmitted on the port since system
+ re-initialization and while the port state was 'up'
+ or 'test' because data was not available to the
+ transmitter in time."
+ ::= { rs232SyncPortEntry 4 }
+
+rs232SyncPortReceiveOverrunErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of frames that failed to be received
+ on the port since system re-initialization and while
+ the port state was 'up' or 'test' because the
+ receiver did not accept the data in time."
+ ::= { rs232SyncPortEntry 5 }
+
+rs232SyncPortInterruptedFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of frames that failed to be received
+ or transmitted on the port due to loss of modem
+ signals since system re-initialization and while the
+ port state was 'up' or 'test'."
+ ::= { rs232SyncPortEntry 6 }
+
+rs232SyncPortAbortedFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of frames aborted on the port due to
+ receiving an abort sequence since system
+ re-initialization and while the port state was 'up'
+ or 'test'."
+ ::= { rs232SyncPortEntry 7 }
+
+rs232SyncPortRole OBJECT-TYPE
+ SYNTAX INTEGER { dte(1), dce(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The role the device is playing that is using this port.
+ dte means the device is performing the role of
+ data terminal equipment
+ dce means the device is performing the role of
+ data circuit-terminating equipment."
+ DEFVAL { dce }
+ ::= { rs232SyncPortEntry 8 }
+
+rs232SyncPortEncoding OBJECT-TYPE
+ SYNTAX INTEGER { nrz(1), nrzi(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The bit stream encoding technique that is in effect
+ for this port.
+ nrz for Non-Return to Zero encoding
+ nrzi for Non-Return to Zero Inverted encoding."
+ DEFVAL { nrz }
+ ::= { rs232SyncPortEntry 9 }
+
+rs232SyncPortRTSControl OBJECT-TYPE
+ SYNTAX INTEGER { controlled(1), constant(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The method used to control the Request To Send (RTS)
+ signal.
+
+ controlled when the DTE is asserts RTS each time
+ data needs to be transmitted and drops
+ RTS at some point after data
+ transmission begins.
+
+ If rs232SyncPortRole is 'dte', the
+ RTS is an output signal. The device
+ will issue a RTS and wait for a CTS
+ from the DCE before starting to
+ transmit.
+
+ If rs232SyncPortRole is 'dce', the
+ RTS is an input signal. The device
+ will issue a CTS only after having
+ received RTS and waiting the
+ rs232SyncPortRTSCTSDelay interval.
+
+ constant when the DTE constantly asserts RTS."
+ DEFVAL { constant }
+ ::= { rs232SyncPortEntry 10 }
+
+rs232SyncPortRTSCTSDelay OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The interval (in milliseconds) that the DCE must wait
+ after it sees RTS asserted before asserting CTS. This
+ object exists in support of older synchronous devices
+ that cannot recognize CTS within a certain interval
+ after it asserts RTS."
+ DEFVAL { 0 }
+ ::= { rs232SyncPortEntry 11 }
+
+rs232SyncPortMode OBJECT-TYPE
+ SYNTAX INTEGER { fdx(1), hdx(2), simplex-receive(3),
+ simplex-send(4) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The mode of operation of the port with respect to the
+ direction and simultaneity of data transfer.
+
+ fdx when frames on the data link can be
+ transmitted and received at the same
+ time
+
+ hdx when frames can either be received
+ from the data link or transmitted
+ onto the data link but not at the
+ same time.
+
+ simplex-receive when frames can only be received on
+ this data link.
+
+ simplex-send when frames can only be sent on this
+ data link."
+ DEFVAL { fdx }
+ ::= { rs232SyncPortEntry 12 }
+
+rs232SyncPortIdlePattern OBJECT-TYPE
+ SYNTAX INTEGER { mark(1), space(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The bit pattern used to indicate an idle line."
+ DEFVAL { space }
+ ::= { rs232SyncPortEntry 13 }
+
+rs232SyncPortMinFlags OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The minimum number of flag patterns this port needs in
+ order to recognize the end of one frame and the start
+ of the next. Plausible values are 1 and 2."
+ DEFVAL { 2 }
+ ::= { rs232SyncPortEntry 14 }
+
+
+-- Input Signal Table
+
+rs232InSigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Rs232InSigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of port input control signal entries
+ implemented and visible to the software on the port,
+ and useful to monitor."
+ ::= { rs232 5 }
+
+rs232InSigEntry OBJECT-TYPE
+ SYNTAX Rs232InSigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Input control signal status for a hardware port."
+ INDEX { rs232InSigPortIndex, rs232InSigName }
+ ::= { rs232InSigTable 1 }
+
+Rs232InSigEntry ::=
+ SEQUENCE {
+ rs232InSigPortIndex
+ InterfaceIndex,
+ rs232InSigName
+ INTEGER,
+ rs232InSigState
+ INTEGER,
+ rs232InSigChanges
+ Counter32
+ }
+
+rs232InSigPortIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of rs232PortIndex for the port to which
+ this entry belongs."
+ ::= { rs232InSigEntry 1 }
+
+rs232InSigName OBJECT-TYPE
+ SYNTAX INTEGER { rts(1), cts(2), dsr(3), dtr(4), ri(5),
+ dcd(6), sq(7), srs(8), srts(9),
+ scts(10), sdcd(11) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Identification of a hardware signal, as follows:
+
+ rts Request to Send
+ cts Clear to Send
+ dsr Data Set Ready
+ dtr Data Terminal Ready
+ ri Ring Indicator
+ dcd Received Line Signal Detector
+ sq Signal Quality Detector
+ srs Data Signaling Rate Selector
+ srts Secondary Request to Send
+ scts Secondary Clear to Send
+ sdcd Secondary Received Line Signal Detector
+ "
+ REFERENCE
+ "EIA Standard RS-232-C, August 1969."
+ ::= { rs232InSigEntry 2 }
+
+rs232InSigState OBJECT-TYPE
+ SYNTAX INTEGER { none(1), on(2), off(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current signal state."
+ ::= { rs232InSigEntry 3 }
+
+rs232InSigChanges OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times the signal has changed from
+ 'on' to 'off' or from 'off' to 'on'."
+ ::= { rs232InSigEntry 4 }
+
+
+-- Output Signal Table
+
+rs232OutSigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Rs232OutSigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of port output control signal entries
+ implemented and visible to the software on the port,
+ and useful to monitor."
+ ::= { rs232 6 }
+
+rs232OutSigEntry OBJECT-TYPE
+ SYNTAX Rs232OutSigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Output control signal status for a hardware port."
+ INDEX { rs232OutSigPortIndex, rs232OutSigName }
+ ::= { rs232OutSigTable 1 }
+
+Rs232OutSigEntry ::=
+ SEQUENCE {
+ rs232OutSigPortIndex
+ InterfaceIndex,
+ rs232OutSigName
+ INTEGER,
+ rs232OutSigState
+ INTEGER,
+ rs232OutSigChanges
+ Counter32
+ }
+
+rs232OutSigPortIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of rs232PortIndex for the port to which
+ this entry belongs."
+ ::= { rs232OutSigEntry 1 }
+
+rs232OutSigName OBJECT-TYPE
+ SYNTAX INTEGER { rts(1), cts(2), dsr(3), dtr(4), ri(5),
+ dcd(6), sq(7), srs(8), srts(9),
+ scts(10), sdcd(11) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Identification of a hardware signal, as follows:
+
+ rts Request to Send
+ cts Clear to Send
+ dsr Data Set Ready
+ dtr Data Terminal Ready
+ ri Ring Indicator
+ dcd Received Line Signal Detector
+ sq Signal Quality Detector
+ srs Data Signaling Rate Selector
+ srts Secondary Request to Send
+ scts Secondary Clear to Send
+ sdcd Secondary Received Line Signal Detector
+ "
+ REFERENCE
+ "EIA Standard RS-232-C, August 1969."
+ ::= { rs232OutSigEntry 2 }
+
+rs232OutSigState OBJECT-TYPE
+ SYNTAX INTEGER { none(1), on(2), off(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current signal state."
+ ::= { rs232OutSigEntry 3 }
+
+rs232OutSigChanges OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times the signal has changed from
+ 'on' to 'off' or from 'off' to 'on'."
+ ::= { rs232OutSigEntry 4 }
+
+
+-- conformance information
+
+rs232Conformance OBJECT IDENTIFIER ::= { rs232 7 }
+
+rs232Groups OBJECT IDENTIFIER ::= { rs232Conformance 1 }
+rs232Compliances OBJECT IDENTIFIER ::= { rs232Conformance 2 }
+
+
+-- compliance statements
+
+rs232Compliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMPv2 entities
+ which have RS-232-like hardware interfaces."
+
+ MODULE -- this module
+ MANDATORY-GROUPS { rs232Group }
+
+ GROUP rs232AsyncGroup
+ DESCRIPTION
+ "The Asynch group is mandatory only for those
+ SNMPv2 entities which have asynchronous
+ interfaces Rs-232-like."
+
+ GROUP rs232SyncGroup
+ DESCRIPTION
+ "The Synch group is mandatory only for those
+ SNMPv2 entities which have synchronous
+ interfaces Rs-232-like."
+ ::= { rs232Compliances 1 }
+
+-- units of conformance
+
+rs232Group OBJECT-GROUP
+ OBJECTS { rs232Number, rs232PortIndex, rs232PortType,
+ rs232PortInSigNumber, rs232PortOutSigNumber,
+ rs232PortInSpeed, rs232PortOutSpeed,
+ rs232PortInFlowType, rs232PortOutFlowType,
+ rs232InSigPortIndex, rs232InSigName,
+ rs232InSigState, rs232InSigChanges,
+ rs232OutSigPortIndex, rs232OutSigName,
+ rs232OutSigState, rs232OutSigChanges }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information
+ applicable to all RS-232-like interfaces."
+ ::= { rs232Groups 1 }
+
+rs232AsyncGroup OBJECT-GROUP
+ OBJECTS { rs232AsyncPortIndex, rs232AsyncPortBits,
+ rs232AsyncPortStopBits, rs232AsyncPortParity,
+ rs232AsyncPortAutobaud, rs232AsyncPortParityErrs,
+ rs232AsyncPortFramingErrs, rs232AsyncPortOverrunErrs }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information
+ applicable to asynchronous RS-232-like interfaces."
+ ::= { rs232Groups 2 }
+
+rs232SyncGroup OBJECT-GROUP
+ OBJECTS { rs232SyncPortIndex, rs232SyncPortClockSource,
+ rs232SyncPortFrameCheckErrs,
+ rs232SyncPortTransmitUnderrunErrs,
+ rs232SyncPortReceiveOverrunErrs,
+ rs232SyncPortInterruptedFrames,
+ rs232SyncPortAbortedFrames }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information
+ applicable to synchronous RS-232-like interfaces."
+ ::= { rs232Groups 3 }
+
+rs232SyncSDLCGroup OBJECT-GROUP
+ OBJECTS { rs232SyncPortRole,
+ rs232SyncPortEncoding,
+ rs232SyncPortRTSControl,
+ rs232SyncPortRTSCTSDelay,
+ rs232SyncPortMode,
+ rs232SyncPortIdlePattern,
+ rs232SyncPortMinFlags }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information
+ applicable to synchronous RS-232-like interfaces
+ running SDLC."
+ ::= { rs232Groups 4 }
+
+END