diff options
Diffstat (limited to 'MIBS/radlan/RADLAN-STACK-MIB')
| -rw-r--r-- | MIBS/radlan/RADLAN-STACK-MIB | 102 |
1 files changed, 102 insertions, 0 deletions
diff --git a/MIBS/radlan/RADLAN-STACK-MIB b/MIBS/radlan/RADLAN-STACK-MIB new file mode 100644 index 0000000..0e88a03 --- /dev/null +++ b/MIBS/radlan/RADLAN-STACK-MIB @@ -0,0 +1,102 @@ +RADLAN-STACK-MIB DEFINITIONS ::= BEGIN + +-- Title: RADLAN LOCALIZATION ROS +-- This Private MIB supports the unit id configuration for stack of ROS products +-- Version: 7.40 +-- Date: 21 Nov 2005 +-- +-- 01-Nov-2005 Add rlStackUnitMacAddressAfterReset +-- 21-Nov-2005 Change range of rlStackActiveUnitIdAfterReset + +IMPORTS + MacAddress FROM BRIDGE-MIB + rnd FROM RADLAN-MIB OBJECT-TYPE, + MODULE-IDENTITY FROM SNMPv2-SMI + TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC; + + +rlStack MODULE-IDENTITY + LAST-UPDATED "200504140000Z" + ORGANIZATION "Radlan Computer Communications Ltd." + CONTACT-INFO + "radlan.com" + DESCRIPTION + "The private MIB module definition for stack." + REVISION "200504140000Z" + DESCRIPTION + "Initial revision." + ::= { rnd 107 } + +rlStackActiveUnitIdTable OBJECT-TYPE + SYNTAX SEQUENCE OF RlStackActiveUnitIdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " The table listing the active unit id of the requested unit." + ::= {rlStack 1 } + +rlStackActiveUnitIdEntry OBJECT-TYPE + SYNTAX RlStackActiveUnitIdEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + " An entry in the rlStackActiveUnitIdTable." + INDEX {rlStackCurrentUnitId } + ::= {rlStackActiveUnitIdTable 1 } + +RlStackActiveUnitIdEntry ::= SEQUENCE { + rlStackCurrentUnitId INTEGER, + rlStackActiveUnitIdAfterReset INTEGER +} + +rlStackCurrentUnitId OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The unit number device, which is the active unit id" + ::= {rlStackActiveUnitIdEntry 1 } + + +rlStackActiveUnitIdAfterReset OBJECT-TYPE + SYNTAX INTEGER (0..255) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Indicates the unit id that will be after reset." + ::= {rlStackActiveUnitIdEntry 2 } + +rlStackUnitModeAfterReset OBJECT-TYPE + SYNTAX INTEGER { + standalone(1), + stack(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "set unit type that will be after reset, standalone or stack." + ::= {rlStack 2 } + +rlStackUnitMode OBJECT-TYPE + SYNTAX INTEGER { + standalone(1), + stack(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "show unit type standalone or stack." + ::= {rlStack 3 } + +rlStackUnitMacAddressAfterReset OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The MAC address used by this bridge after rest." + REFERENCE + "IEEE 802.1D-1990: Sections 6.4.1.1.3 and 3.12.5" + ::= { rlStack 4 } + +END + |