diff options
Diffstat (limited to 'MIBS/raisecom/RAISECOM-OPTICAL-TRANSCEIVER-MIB')
| -rw-r--r-- | MIBS/raisecom/RAISECOM-OPTICAL-TRANSCEIVER-MIB | 2868 |
1 files changed, 2868 insertions, 0 deletions
diff --git a/MIBS/raisecom/RAISECOM-OPTICAL-TRANSCEIVER-MIB b/MIBS/raisecom/RAISECOM-OPTICAL-TRANSCEIVER-MIB new file mode 100644 index 0000000..34f558e --- /dev/null +++ b/MIBS/raisecom/RAISECOM-OPTICAL-TRANSCEIVER-MIB @@ -0,0 +1,2868 @@ +--MibName=raisecomOpticalMonitorMIB +-- ***************************************************************** +-- RAISECOM-OPTICAL-TRANSCEIVER-MIB.my +-- +-- Copyright(c) 2003-2005 by RAISECOM TECH, Ltd. +-- All rights reserved. +-- ***************************************************************** + +-- ***************************************************************** +-- Modi Report:Format: <number>, <time>, <author>, <desc> +-- 01, 20110623, yangzhognhong, change the value of the node raisecomOpticalTransceiverMediaType +-- for SFP+ development +-- +-- ***************************************************************** + + +RAISECOM-OPTICAL-TRANSCEIVER-MIB DEFINITIONS ::= BEGIN + +IMPORTS + Integer32, Unsigned32, + MODULE-IDENTITY, + NOTIFICATION-TYPE, + OBJECT-TYPE, + TimeTicks FROM SNMPv2-SMI + raisecomAgent + FROM RAISECOM-BASE-MIB + TEXTUAL-CONVENTION FROM SNMPv2-TC + MODULE-COMPLIANCE, + NOTIFICATION-GROUP, + OBJECT-GROUP FROM SNMPv2-CONF + ifIndex FROM IF-MIB + raisecomNotificationLocation FROM RAISECOM-COMMON-MANAGEMENT-MIB + ClearVar FROM SWITCH-TC; + +raisecomOpticalTransceiver MODULE-IDENTITY + LAST-UPDATED "201005190000Z" + ORGANIZATION "Raisecom, Inc." + CONTACT-INFO + " Raise Systems + + Postal: Beijing, + China + + Tel: 86-010-82884499 + + E-mail: chenyu@raisecom.com" + DESCRIPTION + "This MIB module defines objects to monitor optical + characteristics on the optical interfaces in a network element. " + REVISION "201005190000Z" + DESCRIPTION + "The initial revision of this MIB." + ::={ raisecomAgent 18 } + + +-- Textual Conventions +EnableVar ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "enable or disable a function." + SYNTAX INTEGER { + enable(1), + disable(2) + } + +OpticalParameterType ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This value indicates the optical parameter that is + being monitored. Valid values are -OpticalParameterType + + transceiverTemperature(1) :transceiver temperature + txbiasCurrent(2) :TX bias current + txPower(3) :TX output power + rxPower(4) :RX received optical power + laserTemperature(5) :laser temperature + p5V0supplyVoltage(6) :+5V supply voltage + p3V3supplyVoltage(7) :+3.3V supply voltage + p1V8supplyVoltage(8) :+1.8V supply voltage + n5V2supplyVoltage(9) :-5.2V supply voltage + apdBiasVoltage(10) :APD bias voltage + p5V0supplyCurrent(11) :+5V supply currnet + p3V3supplyCurrent(12) :+3.3V supply currnet + p1V8supplyCurrent(13) :+1.8V supply currnet + n5V2supplyCurrent(14) :-5.2V supply currnet + tecCurrent(15) :TEC currnet + laserWavelength(16) :laser wavelength + + " + + SYNTAX INTEGER { + transceiverTemperature (1), + txbiasCurrent (2), + txPower (3), + rxPower (4), + laserTemperature(5), + p5V0supplyVoltage(6), + p3V3supplyVoltage(7), + p1V8supplyVoltage(8), + n5V2supplyVoltage(9), + apdBiasVoltage(10), + p5V0supplyCurrent(11), + p3V3supplyCurrent(12), + p1V8supplyCurrent(13), + n5V2supplyCurrent(14), + tecCurrent(15), + laserWavelength(16) + + } + + +OpticalParameterValue ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The value of the optical parameter that is being monitored. + The range of values varies depending on the type of optical parameter being monitored, + as identified by a corresponding object with syntax OpticalParameterType. + When the optical parameter being monitored is 'XXTemperature',the supported range + is from -40000 to 125000, in units of 1/1000 degrees centigrade. + Example: A value of 23500 represents a temperature reading of 23.5 degrees C. + The temperature is shown in unit of degrees centigrade, and the precision is 0.1. + When the optical parameter being monitored is 'txbiasCurrent',the supported range + is from 0 to 131000, in units of 1/1000 mA. + Example: A value of 1000 represents a TX bias current reading of 1.0mA. + The 'txbiasCurrent'is shown in unit of mA, and the precision is 0.1. + When the optical parameter being monitored is 'txPower',the supported range + is from -40000 to 8200, in units of 1/1000 dbm. + Example: A value of 77800 represents a TX output power reading of 7.78 dBm. + The 'txPower' is shown in unit of dBm, and the precision is 0.1. + When the optical parameter being monitored is 'rxPower',the supported range + is from -40000 to 8200, in units of 1/1000 dbm. + Example: A value of 7780 represents a RX received optical power reading of 7.78 dBm. + The 'rxPower' is shown in unit of dBm, and the precision is 0.1. + When the optical parameter being monitored is 'XXsupplyVoltage',the supported range + is from 0 to 6550, in units of 1/1000 V. + Example: A value of 6000 represents a XX supply Voltage eading of 6.00V. + The 'XXsupplyVoltage'is shown in unit of V, and the precision is 0.01. + When the optical parameter being monitored is 'apdBiasVoltage,the supported range + is from 0 to 655300 , in units of 1/1000 V . + Example: A value of 600000 represents a APD BiasVoltage reading of 600.0V. + The 'apdBiasVoltage' is shown in unit of V, and the precision is 0.1. + When the optical parameter being monitored is 'XXsupplyCurrent',the supported range + is from 0 to 6553600, in units of 1/1000 mA . + Example: A value of 6000000 represents a XX supply current reading of 6000.0mA. + The 'XXsupplyCurrent' is shown in unit of mA, and the precision is 0.1. + When the optical parameter being monitored is 'tecCurrent',the supported range + is from 0 to 6553600, in units of 1/1000 mA . + Example: A value of 6000000 represents a TEC Current reading of 6000.0mA. + The 'tecCurrent' is shown in unit of mA, and the precision is 0.1. + When the optical parameter being monitored is 'laserWavelength,the supported range + is from 0 to 3276750, in units of 1/1000 nm . + Example: A value of 3000000 represents a laser wavelength reading of 3000.0nm. + The 'laserWavelength'is shown in unit of nm, and the precision is 0.01. + " + SYNTAX Integer32 (-1000000 | -40000..6553600) + +OpticalPMPeriod ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "This value indicates the time period over which performance + monitoring data has been collected." + SYNTAX INTEGER { + fifteenMin(1), + twentyFourHour(2) + } + +-- MIB Global Enable Definitions + +raisecomOpticalTransceiverGlobalEnable OBJECT IDENTIFIER ::= + {raisecomOpticalTransceiver 1 } + +raisecomOpticalTransceiverNotifyEnable OBJECT-TYPE + SYNTAX EnableVar + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies the generation of device notifications, + enable or disable. + + this object belongs to xfp and sfp. + " + DEFVAL { disable } + ::={ raisecomOpticalTransceiverGlobalEnable 1 } + +raisecomOpticalTransceiverDDMEnable OBJECT-TYPE + SYNTAX EnableVar + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable or disable digitaldiagnotic on the device. + + this object belongs to xfp and sfp. + " + DEFVAL { disable} + ::={ raisecomOpticalTransceiverGlobalEnable 2 } + +raisecomOpticalTransceiverCheckPwdEnable OBJECT-TYPE + SYNTAX EnableVar + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies the status of password checking on the device, + enable or disable. + + this object belongs to xfp. + " + DEFVAL { disable} + ::={ raisecomOpticalTransceiverGlobalEnable 3 } + +raisecomOpticalTransceiverPollInterval OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies the value of poll-interval on the device. + + this object belongs to xfp and sfp. + " + ::={ raisecomOpticalTransceiverGlobalEnable 4 } + +-- MIB Object Definitions + +raisecomOpticalTransceiverObjects OBJECT IDENTIFIER ::= + {raisecomOpticalTransceiver 2 } + +-- groups in this MIB module +raisecomOpticalTransceiverInfoGroup OBJECT IDENTIFIER ::= + {raisecomOpticalTransceiverObjects 1 } + +raisecomOpticalTransceiverDDMGroup OBJECT IDENTIFIER ::= + {raisecomOpticalTransceiverObjects 2 } + +raisecomOpticalTransceiverPMGroup OBJECT IDENTIFIER ::= + {raisecomOpticalTransceiverObjects 3 } + +raisecomOpticalTransceiverStatusGroup OBJECT IDENTIFIER ::= + {raisecomOpticalTransceiverObjects 4 } + +-- raisecomOpticalTransceiverInfoTable + +raisecomOpticalTransceiverInfoTable OBJECT-TYPE + SYNTAX SEQUENCE OF RaisecomOpticalTransceiverInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Trancetver information Table." + ::= { raisecomOpticalTransceiverInfoGroup 1 } + +raisecomOpticalTransceiverInfoEntry OBJECT-TYPE + SYNTAX RaisecomOpticalTransceiverInfoEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the raisecomOpticalTransceiverInfoTable." + INDEX { ifIndex } + ::={ raisecomOpticalTransceiverInfoTable 1 } + + +RaisecomOpticalTransceiverInfoEntry ::= SEQUENCE { + raisecomOpticalTransceiverType INTEGER, + raisecomOpticalTransceiverConnectorType INTEGER, + raisecomOpticalTransceiverVendorName OCTET STRING, + raisecomOpticalTransceiverVendorPN OCTET STRING, + raisecomOpticalTransceiverVendorSN OCTET STRING, + raisecomOpticalTransceiverMediaType INTEGER, + raisecomOpticalTransceiverTransmissionDistance Integer32, + raisecomOpticalTransceiverAbility Unsigned32, + raisecomOpticalTransceiverDDM INTEGER, + raisecomOpticalTransceiverCalibrationType INTEGER, + raisecomOpticalTransceiverRSSI INTEGER, + raisecomOpticalTransceiverVendorRev OCTET STRING, + raisecomOpticalTransceiverBRMax INTEGER, + raisecomOpticalTransceiverBRMin INTEGER, + raisecomOpticalTransceiverWavelengthContrl INTEGER, + raisecomOpticalTransceiverWavelength Integer32, + raisecomOpticalTransceiverWaveTolerance OCTET STRING, + raisecomOpticalTransceiverCompatibility OCTET STRING, + raisecomOpticalTransceiverPowerDissipation INTEGER, + raisecomOpticalTransceiverCDR INTEGER, + raisecomOpticalTransceiverRefClock INTEGER, + raisecomOpticalTransceiverTransmitterType INTEGER, + raisecomOpticalTransceiverCooled INTEGER, + raisecomOpticalTransceiverTunalbe INTEGER, + raisecomOpticalTransceiverDetectorType INTEGER, + raisecomOpticalTransceiverLineLoopBack INTEGER, + raisecomOpticalTransceiverXFILoopBack INTEGER, + raisecomOpticalTransceiverVps INTEGER, + raisecomOpticalTransceiverTxDis INTEGER, + raisecomOpticalTransceiverStandby INTEGER, + raisecomOpticalTransceiverInVpsLowPower INTEGER, + raisecomOpticalTransceiverOutVpsLowPower INTEGER, + raisecomOpticalTransceiverFEC INTEGER, + raisecomOpticalTransceiverCMU INTEGER, + raisecomOpticalTransceiverBR INTEGER + +} + +raisecomOpticalTransceiverType OBJECT-TYPE + SYNTAX INTEGER{ + unknown(1), + gbic(2), + soldered(3), + sfp(4), + xbi(5), + xenpak(6), + xfp(7), + xff(8), + xfp-e(9), + xpak(10), + x2(11), + sfpj(12) + } + ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the physical type of the transceiver, + such as xfp or sfp , and so on. + + this object belongs to xfp and sfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 1 } + +raisecomOpticalTransceiverConnectorType OBJECT-TYPE + SYNTAX INTEGER + { + unknown(0), + sc (1), + db9(2), + hssdc(3), + bnc-tnc(4), + fiber-coaxial-head(5), + fiber-jack(6), + lc(7), + mt-rj(8), + mu(9), + sg(10), + fiber-pigtail(11), + mpo-parallel-optic(12), + hssdcII (20), + copper (21), + rj45 (22) + } + ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the connector type of the transceiver, + unknown, sc, db9, hssdc, bnc_tnc, fiber_coaxial_head, fiber_outlet, + lc, mt_rj, mu, sg, fiber_pigtail, mpo_parallel_optic , hssdcII, + copper, rj45. + + this object belongs to xfp and sfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 2 } + +raisecomOpticalTransceiverVendorName OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS current + DESCRIPTION + "Vendor name of the interface. + + this object belongs to xfp and sfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 3 } + +raisecomOpticalTransceiverVendorPN OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS current + DESCRIPTION + "Vendor part number of the interface. + + this object belongs to xfp and sfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 4 } + +raisecomOpticalTransceiverVendorSN OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS current + DESCRIPTION + "Vendor serial number of the interface. + + this object belongs to xfp and sfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 5 } + +raisecomOpticalTransceiverMediaType OBJECT-TYPE + SYNTAX INTEGER + { + single-mode(1), + multi-modeE50(2), + multi-mode50(3), + multi-mode625(4), + copper(5), + single-modeKm(6), + multi-modeOM3(7) + } + ACCESS read-only + STATUS current + DESCRIPTION + "Types of the fiber, + single_mode, multi_modeE50, multi_mode50,multi_mode625,copper. + single_modeKm,multi_modeOM3 + + this object belongs to xfp and sfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 6 } + +raisecomOpticalTransceiverTransmissionDistance OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS current + DESCRIPTION + "The max distance which the interface could transmit, + measured in meter. + The object will be shown in unit of Km, and the precision is 0.001. + + this object belongs to xfp and sfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 7 } + +raisecomOpticalTransceiverAbility OBJECT-TYPE + SYNTAX Unsigned32 + ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the ability of optical module digitaldiagnotic + funtion. Currently, the digitaldiagnotic objects of our optical module + inculde 16 parameters. + + this object has 32 bits, each bit represents a digital diagnotic parameter. + if the bit value is 0, it means that the optical module does not provide + digital diagnotic funtion for relative parameter.if the bit value is 1,it + means that the optical module provides digital diagnotic funtion for + relative parameter. + + this object belongs to xfp and sfp. + + The relation between parameters and bits is following: + 32……16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1: + The relation between parameters and bits is following: + 32……16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1: + | 1bit | 2bit | 3bit | 4bit + | APD偏置电压 | 0(保留) | TEC电流 | 激光器温度 + + | 5bit | 6bit |7bit | 8bit + | 激光器波长 | +5V供电电压 | +3.3V供电电压 | +1.8V供电电压 + + | 9bit | 10bit |11bit | 12bit + | -5.2V供电电压 | +5V供电电流 | 0(无) | 0(无) + + | 13bit | 14bit | 15bit | 16bit + | +3.3V供电电流 | +1.8V供电电流 | -5.2V供电电流 | 模块温度 + + | 17bit | 18bit | 19bit | 20bit ~ 32bit + | 激光器偏置电流 | 发送光功率 |接收光功率 | 0 + + But when the optical module is sfp, the 6 bit will represents + the supplyVoltage of sfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 8 } + +raisecomOpticalTransceiverDDM OBJECT-TYPE + SYNTAX INTEGER{ + support(1), + notsupport(2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies if the transceiver supports on digital diagnostic function, + support or not support.To the xfp, the default value of this object is support. + + this object belongs to xfp and sfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 9 } + +raisecomOpticalTransceiverCalibrationType OBJECT-TYPE + SYNTAX INTEGER{ + unknown(1), + internal(2), + external(3) + } + ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the calibration type of the transceiver, + internal, external, unknown. + + this object belongs to xfp and sfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 10 } + +raisecomOpticalTransceiverRSSI OBJECT-TYPE + SYNTAX INTEGER{ + support(1), + notsupport(2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the calibration type of the transceiver, + support or not support. + + this object belongs to xfp and sfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 11 } + +raisecomOpticalTransceiverVendorRev OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS current + DESCRIPTION + " the version number of the transceiver. + this object belongs to xfp and sfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 12 } + +raisecomOpticalTransceiverBRMax OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS current + DESCRIPTION + " the min data rate of the transceiver,mesured in Mbps . + this object belongs to xfp and sfp. + + The object will be shown in unit of Gbps, and the precision is 0.1. + " + ::= { raisecomOpticalTransceiverInfoEntry 13 } + +raisecomOpticalTransceiverBRMin OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS current + DESCRIPTION + " the min data rate of the transceiver,mesured in Mbps. + + this object belongs to xfp and sfp.To the sfp, + the min data rate value is equal to the max data rate value. + + The object will be shown in unit of Gbps, and the precision is 0.1. + " + ::= { raisecomOpticalTransceiverInfoEntry 14 } + +raisecomOpticalTransceiverWavelengthContrl OBJECT-TYPE + SYNTAX INTEGER + { + support(1), + notsupport (2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "if the transceiver supports on wavelength control + support,notsupport. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 15 } + +raisecomOpticalTransceiverWavelength OBJECT-TYPE + SYNTAX Integer32 + ACCESS read-only + STATUS current + DESCRIPTION + "Wavelength of the interface, measured in pm(0.001nm). + this object belongs to xfp. + The object will be shown in unit of nm, and the precision is 0.01. + " + ::= { raisecomOpticalTransceiverInfoEntry 16 } + +raisecomOpticalTransceiverWaveTolerance OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS current + DESCRIPTION + "the range of laser wavelength from nominal wavelength,mesured in pm(0.001*nm). + this object belongs to xfp. + The object will be shown in unit of nm, and the precision is 0.01. + " + ::= { raisecomOpticalTransceiverInfoEntry 17 } + +raisecomOpticalTransceiverCompatibility OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS current + DESCRIPTION + "the compatibility type that the transceiver supports,such as 10GBASE-SR. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 18 } + +raisecomOpticalTransceiverPowerDissipation OBJECT-TYPE + SYNTAX INTEGER + { + p1W5(1), + p2W5(2), + p3W5(3), + exceed(4) + } + ACCESS read-only + STATUS current + DESCRIPTION + "the max power dissipation of the transceiver, + p1W5,p2W5,p3W5,exceed3W5. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 19 } + +raisecomOpticalTransceiverCDR OBJECT-TYPE + SYNTAX INTEGER + { + support(1), + notsupport(2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "the optical module supports on CDR fundtion. + support,notsupport. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 20 } + +raisecomOpticalTransceiverRefClock OBJECT-TYPE + SYNTAX INTEGER + { + required(1), + notrequired (2) + } + ACCESS read-only + STATUS current + DESCRIPTION + " if the transceiver requires outside reference clock + required,notrequired. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 21 } + +raisecomOpticalTransceiverTransmitterType OBJECT-TYPE + SYNTAX INTEGER + { + vcsel850nm(1), + vcsel1310nm(2), + vcsel1550nm(3), + fp1310nm(4), + dfb1310nm(5), + dfb1550nm(6), + eml1310nm(7), + eml1550nm(8), + copper-others(9) + } + + ACCESS read-only + STATUS current + DESCRIPTION + "The transmitter type of the transceiver,such as 850 nm VCSEL. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 22 } + +raisecomOpticalTransceiverCooled OBJECT-TYPE + SYNTAX INTEGER + { + cooled(1), + uncooled (2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "The transmitter cooled type of the transceiver + cooled,uncooled. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 24 } + +raisecomOpticalTransceiverTunalbe OBJECT-TYPE + SYNTAX INTEGER + { + tunable (1), + untunable (2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "The transmitter tunable type of the transceiver + tunable,untunable. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 25 } + +raisecomOpticalTransceiverDetectorType OBJECT-TYPE + SYNTAX INTEGER + { + pin(1), + apd(2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "The detector type of the transceiver + pin, apd. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 26 } + +raisecomOpticalTransceiverLineLoopBack OBJECT-TYPE + SYNTAX INTEGER + { + support(1), + notsupport(2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "The transceiver support status of sideline loop-back control + support,notsupport. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 27 } + +raisecomOpticalTransceiverXFILoopBack OBJECT-TYPE + SYNTAX INTEGER + { + support(1), + notsupport(2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "The transceiver support status of XFI loop-back control + support,notsupport. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 28 } + +raisecomOpticalTransceiverVps OBJECT-TYPE + SYNTAX INTEGER + { + support(1), + notsupport(2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies if the optical module supports on VPS + support,notsupport. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 29 } + +raisecomOpticalTransceiverTxDis OBJECT-TYPE + SYNTAX INTEGER + { + support(1), + notsupport(2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "The transceiver support status of software control the transmitter status + support,notsupport. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 30 } + +raisecomOpticalTransceiverStandby OBJECT-TYPE + SYNTAX INTEGER + { + support(1), + notsupport(2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "The transceiver support status of software control the standby mode. + support,notsupport. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 31 } + +raisecomOpticalTransceiverInVpsLowPower OBJECT-TYPE + SYNTAX INTEGER + { + support(1), + notsupport(2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "The VPS in low power support status of the transceiver + support,notsupport. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 32 } + +raisecomOpticalTransceiverOutVpsLowPower OBJECT-TYPE + SYNTAX INTEGER + { + support(1), + notsupport(2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "The VPS out low power support status of the transceiver + support,notsupport. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 33 } + +raisecomOpticalTransceiverFEC OBJECT-TYPE + SYNTAX INTEGER + { + support(1), + notsupport(2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "The FEC support status of transceiver + support,notsupport. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 34 } + +raisecomOpticalTransceiverCMU OBJECT-TYPE + SYNTAX INTEGER + { + support(1), + notsupport(2) + } + ACCESS read-only + STATUS current + DESCRIPTION + "The CMU support status of transceiver + support,notsupport. + this object belongs to xfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 35 } + +raisecomOpticalTransceiverBR OBJECT-TYPE + SYNTAX INTEGER + { + unknown(0), + bitrate-125Mbps(1), + bitrate-155Mbps (2), + bitrate-622Mbps(6), + bitrate-1DOT25Gbps(13), + bitrate-2DOT5Gbps(19) + } + ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the Nominal bitrate of the transceiver, + 125Mbps, 155Mbps, 622Mbps, 1.25Gbps, 2.5Gbps. + + this object belongs to xfp and sfp. + " + ::= { raisecomOpticalTransceiverInfoEntry 36 } + +-- raisecomOpticalDDMTable + +raisecomOpticalTransceiverDDMTable OBJECT-TYPE + SYNTAX SEQUENCE OF RaisecomOpticalTransceiverDDMEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table provides objects to monitor optical + parameters in a network element. " + ::={ raisecomOpticalTransceiverDDMGroup 1 } + +raisecomOpticalTransceiverDDMEntry OBJECT-TYPE + SYNTAX RaisecomOpticalTransceiverDDMEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the raisecomOpticalTransceiverMonTable provides objects to + monitor an optical parameter at an optical interface. + " + INDEX { ifIndex, + raisecomOpticalTransceiverParameterType + } + ::={ raisecomOpticalTransceiverDDMTable 1 } + +RaisecomOpticalTransceiverDDMEntry ::= SEQUENCE { + raisecomOpticalTransceiverParameterType OpticalParameterType, + raisecomOpticalTransceiverParameterValue OpticalParameterValue, + raisecomOpticalTransceiverParamHighAlarmThresh OpticalParameterValue, + raisecomOpticalTransceiverParamHighWarningThresh OpticalParameterValue, + raisecomOpticalTransceiverParamLowAlarmThresh OpticalParameterValue, + raisecomOpticalTransceiverParamLowWarningThresh OpticalParameterValue, + raisecomOpticalTransceiverParamAlarmStatus INTEGER, + raisecomOpticalTransceiverParamAlarmLastValue OpticalParameterValue, + raisecomOpticalTransceiverParamAlarmLastChange TimeTicks, + raisecomOpticalTransceiverDDM15MinValidIntervals Unsigned32, + raisecomOpticalTransceiverDDM24HrValidIntervals Unsigned32, + raisecomOpticalTransceiverDDMValidStatus INTEGER +} + +raisecomOpticalTransceiverParameterType OBJECT-TYPE + SYNTAX OpticalParameterType + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object specifies the optical parameter that is being + monitored in this entry. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverDDMEntry 1 } + +raisecomOpticalTransceiverParameterValue OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the value measured for the particular + optical parameter specified by the raisecomOpticalMonParameterType + object. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverDDMEntry 2 } + +raisecomOpticalTransceiverParamHighAlarmThresh OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the high alarm threshold on the + optical parameter being monitored. + + An alarm condition will be raised if the value given by + raisecomOpticalParameterValue goes from below the value of + this object to above the value of this object, or if + the initial value of raisecomOpticalParameterValue exceeds the value + of this object. This alarm will be indicated in the + raisecomOpticalParamAlarmStatus object. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverDDMEntry 3 } + +raisecomOpticalTransceiverParamHighWarningThresh OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to set a high warning threshold on + the optical parameter being monitored. + + A threshold crossing condition will be indicated if the value + given by raisecomOpticalParameterValue goes from below the value + of this object to above the value of this + object, or if the initial value of raisecomOpticalParameterValue + exceeds the value of this object. This alarm will be indicated in the + raisecomOpticalParamAlarmStatus object. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverDDMEntry 4 } + +raisecomOpticalTransceiverParamLowAlarmThresh OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to set a low alarm threshold on the + optical parameter being monitored. + + An alarm condition will be raised if the value given by + raisecomOpticalParameterValue goes from above the value of + this object to below the value of this object, or if + the initial value of raisecomOpticalParameterValue is lower than the + value of this object. This alarm + will be indicated in the raisecomOpticalParamAlarmStatus object .. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverDDMEntry 5 } + +raisecomOpticalTransceiverParamLowWarningThresh OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to set a low warning threshold on + the optical parameter being monitored. + + A threshold crossing condition will be indicated if the value + given by raisecomOpticalParameterValue goes from above the value + of this object to below the value of this + object, or if the initial value of raisecomOpticalParameterValue + object is lower than the value of this object. For + network elements in the status + indications, this threshold violation will be indicated in the + raisecomOpticalParamAlarmStatus object . + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverDDMEntry 6 } + +raisecomOpticalTransceiverParamAlarmStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(0), + normal(1), + high-alarm(2), + high-warning(3), + low-alarm(4), + low-warning(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is used to indicate the current status of + the thresholds for the monitored optical parameter + on the interface. + + If a threshold is currently being exceeded on the + interface, the object will be set. Otherwise, + the object will be set to 1. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverDDMEntry 7 } + +raisecomOpticalTransceiverParamAlarmLastValue OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the optical parameter value at the last time + a threshold related to a particular optical parameter was + exceeded on the interface. + If no threshold value is currently being + exceeded, then the value '-1000000' is returned. + + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverDDMEntry 8 } + +raisecomOpticalTransceiverParamAlarmLastChange OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the value of sysUpTime at the last time + a threshold related to a particular optical parameter was + exceeded on the interface. + + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverDDMEntry 9 } + +raisecomOpticalTransceiverDDM15MinValidIntervals OBJECT-TYPE + SYNTAX Unsigned32 (0..96) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the number of previous 15 minute + intervals for which valid performance monitoring data + has been stored on the interface. + + The value of this object will be n (where n is the maximum + number of 15 minute intervals supported at this interface), + unless the measurement was (re-)started within the last + (nx15) minutes, in which case the value will be the + number of previous 15 minute intervals for which the agent + has some data. + + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverDDMEntry 10 } + +raisecomOpticalTransceiverDDM24HrValidIntervals OBJECT-TYPE + SYNTAX Unsigned32 (0..7) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the number of previous 24 hour intervals + for which valid performance monitoring data has been stored + on the interface. The max value of this object is 7, it + means that the user can look up 7days history information. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverDDMEntry 11 } + +raisecomOpticalTransceiverDDMValidStatus OBJECT-TYPE + SYNTAX INTEGER { + unknown(0), + valid(1), + invalid(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the parameter row is valid or invalid. + The object value is 'valide' when the module is present and + supporting digitaldiagnotic. The object value is 'invalid' + when the module is absent, or when the module is present and + not supporting digitaldiagnotic. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverDDMEntry 12 } + +-- raisecomOpticalTransceiverPMCurrent Table +raisecomOpticalTransceiverPMCurrentTable OBJECT-TYPE + SYNTAX SEQUENCE OF RaisecomOpticalTransceiverPMCurrentEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains performance monitoring data for the + various optical parameters, collected over the current 15 + minute or the current 24 hour interval." + ::={ raisecomOpticalTransceiverPMGroup 1 } + +raisecomOpticalTransceiverPMCurrentEntry OBJECT-TYPE + SYNTAX RaisecomOpticalTransceiverPMCurrentEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the raisecomOpticalTransceiverPMCurrentTable. It contains + performance monitoring data for a monitored optical + parameter at an interface, collected over the current 15 + minute or the current 24 hour interval. + " + INDEX { ifIndex, + raisecomOpticalTransceiverPMCurrentPeriod, + raisecomOpticalTransceiverPMCurrentParamType } + ::={ raisecomOpticalTransceiverPMCurrentTable 1 } + +RaisecomOpticalTransceiverPMCurrentEntry ::= SEQUENCE { + raisecomOpticalTransceiverPMCurrentPeriod OpticalPMPeriod, + raisecomOpticalTransceiverPMCurrentParamType OpticalParameterType, + raisecomOpticalTransceiverPMCurrentMaxParam OpticalParameterValue, + raisecomOpticalTransceiverPMCurrentMinParam OpticalParameterValue, + raisecomOpticalTransceiverPMCurrentMeanParam OpticalParameterValue +} + +raisecomOpticalTransceiverPMCurrentPeriod OBJECT-TYPE + SYNTAX OpticalPMPeriod + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object indicates whether the optical parameter values + given in this entry are collected over the current 15 minute or + the current 24 hour interval. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverPMCurrentEntry 1 } + +raisecomOpticalTransceiverPMCurrentParamType OBJECT-TYPE + SYNTAX OpticalParameterType + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object specifies the optical parameter that is being + monitored, in this entry. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverPMCurrentEntry 2 } + +raisecomOpticalTransceiverPMCurrentMaxParam OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the maximum value measured for the monitored + optical parameter, in the current 15 minute or the current + 24 hour interval. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverPMCurrentEntry 3 } + +raisecomOpticalTransceiverPMCurrentMinParam OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the minimum value measured for the monitored + optical parameter, in the current 15 minute or the current + 24 hour interval. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverPMCurrentEntry 4 } + +raisecomOpticalTransceiverPMCurrentMeanParam OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the average value of the monitored + optical parameter, in the current 15 minute or the current + 24 hour interval. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverPMCurrentEntry 5 } + +-- raisecomOpticalTransceiverPMInterval Table + +raisecomOpticalTransceiverPMIntervalTable OBJECT-TYPE + SYNTAX SEQUENCE OF RaisecomOpticalTransceiverPMIntervalEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table stores performance monitoring data for the + various optical parameters, collected over previous + intervals. + + This table can have entries for one complete 24 hour + interval and up to 96 complete 15 minute + intervals. A system is required to store at least + 4 completed 15 minute intervals. The number of valid + 15 minute intervals in this table is indicated by the + raisecomOpticalTransceiverDDM15MinValidIntervals object + and the number of valid 24 hour intervals is indicated by the + raisecomOpticalTransceiverDDM24HrValidIntervals object. + + when the optical module is removed from the device, the relative + history records will be cleaned. + " + ::={ raisecomOpticalTransceiverPMGroup 2 } + +raisecomOpticalTransceiverPMIntervalEntry OBJECT-TYPE + SYNTAX RaisecomOpticalTransceiverPMIntervalEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the raisecomOpticalTransceiverPMIntervalTable. It contains + performance monitoring data for an optical parameter, + collected over a previous interval. + " + INDEX { ifIndex, + raisecomOpticalTransceiverPMIntervalPeriod, + raisecomOpticalTransceiverPMIntervalNumber, + raisecomOpticalTransceiverPMIntervalParamType } + ::={ raisecomOpticalTransceiverPMIntervalTable 1 } + +RaisecomOpticalTransceiverPMIntervalEntry ::= SEQUENCE { + raisecomOpticalTransceiverPMIntervalPeriod OpticalPMPeriod, + raisecomOpticalTransceiverPMIntervalNumber Integer32, + raisecomOpticalTransceiverPMIntervalParamType OpticalParameterType, + raisecomOpticalTransceiverPMIntervalMaxParam OpticalParameterValue, + raisecomOpticalTransceiverPMIntervalMinParam OpticalParameterValue, + raisecomOpticalTransceiverPMIntervalMeanParam OpticalParameterValue + } + +raisecomOpticalTransceiverPMIntervalPeriod OBJECT-TYPE + SYNTAX OpticalPMPeriod + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object indicates whether the optical parameter values, + given in this entry, are collected over a period of 15 minutes + or 24 hours. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverPMIntervalEntry 1 } + +raisecomOpticalTransceiverPMIntervalNumber OBJECT-TYPE + SYNTAX Integer32 (1..96) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A number between 1 and 96, which identifies the + interval for which the set of optical parameter values is + available. The interval identified by 1 is the most recently + completed 15 minute or 24 hour interval, and the interval + identified by N is the interval immediately preceding the one + identified by N-1. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverPMIntervalEntry 2 } + +raisecomOpticalTransceiverPMIntervalParamType OBJECT-TYPE + SYNTAX OpticalParameterType + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object specifies the optical parameter that is being + monitored, in this entry. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverPMIntervalEntry 3 } + +raisecomOpticalTransceiverPMIntervalMaxParam OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the maximum value measured for the optical + parameter, in a particular 15 minute or 24 hour interval. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverPMIntervalEntry 4 } + +raisecomOpticalTransceiverPMIntervalMinParam OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the minimum value measured for the optical + parameter, in a particular 15 minute or 24 hour interval. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverPMIntervalEntry 5 } + +raisecomOpticalTransceiverPMIntervalMeanParam OBJECT-TYPE + SYNTAX OpticalParameterValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object gives the average value of the measured optical + parameter, in a particular 15 minute or 24 hour interval. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverPMIntervalEntry 6 } + +-- raisecomOpticalTransceiverCurrentStatus Table +raisecomOpticalTransceiverCurrentStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF RaisecomOpticalTransceiverCurrentStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table stores the hard ware information and the information + set by user of the transceiver. + This object belongs to xfp/sfp. + " + ::={ raisecomOpticalTransceiverStatusGroup 1 } + +raisecomOpticalTransceiverCurrentStatusEntry OBJECT-TYPE + SYNTAX RaisecomOpticalTransceiverCurrentStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the raisecomOpticalTransceiverCurrentStatusTable. It contains + performance monitoring data for an optical parameter, + collected over a previous interval. + This object belongs to xfp/sfp. + " + INDEX { ifIndex } + ::={ raisecomOpticalTransceiverCurrentStatusTable 1 } + +RaisecomOpticalTransceiverCurrentStatusEntry ::= SEQUENCE { + raisecomOpticalTransceiverHwInfoAbsStatus INTEGER, + raisecomOpticalTransceiverHwInfoNRStatus INTEGER, + raisecomOpticalTransceiverHwInfoRxLosStatus INTEGER, + raisecomOpticalTransceiverHwInfoStandby INTEGER, + raisecomOpticalTransceiverHwInfoLaser INTEGER, + raisecomOpticalTransceiverWaveLengthError Integer32, + raisecomOpticalTransceiverUserWaveLength Integer32, + raisecomOpticalTransceiverUserDataRate INTEGER, + raisecomOpticalTransceiverUserLineLoopBack INTEGER, + raisecomOpticalTransceiverUserXFILoopBack INTEGER, + raisecomOpticalTransceiverPortNotifyEnable EnableVar, + raisecomOpticalTransceiverPortDDMEnable EnableVar, + raisecomOpticalTransceiverPortCheckPwdEnable EnableVar, + raisecomOpticalTransceiverTxFaultCount Integer32, + raisecomOpticalTransceiverTxFaultCountClear ClearVar, + raisecomOpticalTransceiverSpecificationCheckStatus INTEGER, + raisecomOpticalTransceiverTxFaultStatus INTEGER + } + +raisecomOpticalTransceiverHwInfoAbsStatus OBJECT-TYPE + SYNTAX INTEGER + { + absent(1), + present(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies if the optical module is absent + present,absent. + This object belongs to xfp and sfp." + ::={ raisecomOpticalTransceiverCurrentStatusEntry 1 } + +raisecomOpticalTransceiverHwInfoNRStatus OBJECT-TYPE + SYNTAX INTEGER + { + ready(1), + notready(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies if the optical module is ready for operation. + ready,notready. + This object belongs to xfp. + " + ::={ raisecomOpticalTransceiverCurrentStatusEntry 2 } + +raisecomOpticalTransceiverHwInfoRxLosStatus OBJECT-TYPE + SYNTAX INTEGER + { + normal(1), + loss(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies if the optical module operation losses the receiving signal + normal,loss. + This object belongs to xfp. + " + ::={ raisecomOpticalTransceiverCurrentStatusEntry 3 } + +raisecomOpticalTransceiverHwInfoStandby OBJECT-TYPE + SYNTAX INTEGER + { + normal(1), + standby(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies if the optical module works under standby mode. + normal,standby. + This object belongs to xfp. + " + ::={ raisecomOpticalTransceiverCurrentStatusEntry 4 } + +raisecomOpticalTransceiverHwInfoLaser OBJECT-TYPE + SYNTAX INTEGER + { + on(1), + off(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies if the optical module laser is turned on + on,off. + This object belongs to xfp. + " + ::={ raisecomOpticalTransceiverCurrentStatusEntry 5 } + +raisecomOpticalTransceiverWaveLengthError OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies error between the actual wavelength + and the wavelength set by the user,measured in pm. + This object belongs to xfp. + The object will be shown in unit of nm, and the precision is 0.001. + " + ::={ raisecomOpticalTransceiverCurrentStatusEntry 6 } + +raisecomOpticalTransceiverUserWaveLength OBJECT-TYPE + SYNTAX Integer32(0..3276800) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies the wavelength value of the optical module set by user,measured in pm. + This object belongs to xfp. + The object will be shown in unit of nm, and the precision is 0.01. + " + ::={ raisecomOpticalTransceiverCurrentStatusEntry 7 } + + +raisecomOpticalTransceiverUserDataRate OBJECT-TYPE + SYNTAX INTEGER(9500..12500) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies the data rate of the optical module set by user,measured in Mbps. + This object belongs to xfp. + The object will be shown in unit of Gbps, and the precision is 0.1. + " + ::={ raisecomOpticalTransceiverCurrentStatusEntry 8 } + +raisecomOpticalTransceiverUserLineLoopBack OBJECT-TYPE + SYNTAX INTEGER + { + normal(1), + lineLoopback(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies if the sideline loop-back is tuned on , + user can change the loop back mode through the object. + normal,lineLoopback. + This object belongs to xfp. + " + ::={ raisecomOpticalTransceiverCurrentStatusEntry 9 } + +raisecomOpticalTransceiverUserXFILoopBack OBJECT-TYPE + SYNTAX INTEGER + { + normal(1), + xfiLoopback(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies if the XFI loop-back is tuned on + user can change the loop back mode through the object. + normal,xfiLoopback. + This object belongs to xfp. + " + ::={ raisecomOpticalTransceiverCurrentStatusEntry 10 } + +raisecomOpticalTransceiverPortNotifyEnable OBJECT-TYPE + SYNTAX EnableVar + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies the generation of a port notifications, + enable or disable. + This object belongs to xfp and sfp. + " + DEFVAL { enable} + ::={ raisecomOpticalTransceiverCurrentStatusEntry 11 } + +raisecomOpticalTransceiverPortDDMEnable OBJECT-TYPE + SYNTAX EnableVar + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies the status of digitaldiagnotic on a port, + enable or disable. + This object belongs to xfp and sfp. + " + DEFVAL { enable} + ::={ raisecomOpticalTransceiverCurrentStatusEntry 12 } + +raisecomOpticalTransceiverPortCheckPwdEnable OBJECT-TYPE + SYNTAX EnableVar + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies the status of password checking on a port, + enable or disable. + This object belongs to xfp. + " + DEFVAL { enable} + ::={ raisecomOpticalTransceiverCurrentStatusEntry 13 } + + raisecomOpticalTransceiverTxFaultCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the number of tx-fault signals." + ::={ raisecomOpticalTransceiverCurrentStatusEntry 14 } + + raisecomOpticalTransceiverTxFaultCountClear OBJECT-TYPE + SYNTAX ClearVar + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies clear the statistcs of tx-fault signals." + ::={ raisecomOpticalTransceiverCurrentStatusEntry 15 } + + raisecomOpticalTransceiverSpecificationCheckStatus OBJECT-TYPE + SYNTAX INTEGER{none(0),accord(1),not-accord(2)} + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the check status, accord(0)specifies + the optical module accord with industrial. not-accord(2) + specifies the optical module not accord with industrial." + ::={ raisecomOpticalTransceiverCurrentStatusEntry 16 } + + raisecomOpticalTransceiverTxFaultStatus OBJECT-TYPE + SYNTAX INTEGER{normal(1),tx-fault(2)} + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the tx-fault status." + ::={ raisecomOpticalTransceiverCurrentStatusEntry 17 } + + +-- Notifications + +raisecomOpticalTransceiverNotifications OBJECT IDENTIFIER ::= + { raisecomOpticalTransceiver 3 } + +raisecomOpticalTransceiverAbsentTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverHwInfoAbsStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module is removed from the device. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 1 } + +raisecomOpticalTransceiverPresentTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverHwInfoAbsStatus, + raisecomOpticalTransceiverSpecificationCheckStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module is plugged into the device. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 2 } + +raisecomOpticalTransceiverNRAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverHwInfoNRStatus } + STATUS current + DESCRIPTION + "This notification is sent when the transmitted or received data of optical module is invalid. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 3 } + +raisecomOpticalTransceiverNRNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverHwInfoNRStatus } + STATUS current + DESCRIPTION + "This notification is sent when the transmitted or received data of optical module is valid. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 4 } + +raisecomOpticalTransceiverRxLosAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverHwInfoRxLosStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module receiving signal is lost. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 5 } + +raisecomOpticalTransceiverRxLosNormaTrap NOTIFICATION-TYPE + OBJECTS {raisecomOpticalTransceiverHwInfoRxLosStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module receiving signal is back to normal. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 6 } + +raisecomOpticalTransceiverCheckPwdFailureTrap NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "This notification is sent when the optical module password checking is failed. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 7 } + +raisecomOpticalTransceiverCheckPwdSucceedTrap NOTIFICATION-TYPE + STATUS current + DESCRIPTION + "This notification is sent when the optical module password cheching is successful. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 8 } + +raisecomOpticalTransceiverParamAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module parameter value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 9 } + +raisecomOpticalTransceiverParamAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module parameter value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 10 } + +raisecomOpticalTransceiverParamWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module parameter value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 11 } + +raisecomOpticalTransceiverParamWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module parameter value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 12 } + +raisecomOpticalTransceiverLaserBackLightAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module password cheching is successful. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 13 } + +raisecomOpticalTransceiverLaserBackLightAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module password cheching is successful. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 14 } + +raisecomOpticalTransceiverLaserLifeAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module password cheching is successful. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 15 } + +raisecomOpticalTransceiverLaserLifeAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module password cheching is successful. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 16 } + +raisecomOpticalTransceiverParamLowAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module parameter value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 17 } + + +raisecomOpticalTransceiverParamLowAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module parameter value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 18 } + +raisecomOpticalTransceiverParamLowWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module parameter value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 19 } + +raisecomOpticalTransceiverParamLowWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module parameter value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverNotifications 20 } + + +-- Parameters and Notifications + +raisecomOpticalTransceiverParamNotifications OBJECT IDENTIFIER ::= + { raisecomOpticalTransceiver 4 } + +raisecomOpticalTransceiverTemperatureAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module Temperature value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 1 } + +raisecomOpticalTransceiverTemperatureAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module Temperature value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 2 } + +raisecomOpticalTransceiverTemperatureWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module Temperature value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 3 } + +raisecomOpticalTransceiverTemperatureWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module Temperature value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 4 } + +raisecomOpticalTransceiverTxbiasCurrentAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module Tx bias Current value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 5 } + +raisecomOpticalTransceiverTxbiasCurrentAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module Tx bias Current value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 6 } + +raisecomOpticalTransceiverTxbiasCurrentWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module Tx bias Current value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 7 } + +raisecomOpticalTransceiverTxbiasCurrentWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module Tx bias Current value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 8 } + +raisecomOpticalTransceiverTxPowerAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module Tx Power value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 9 } + +raisecomOpticalTransceiverTxPowerAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module Tx Power value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 10 } + +raisecomOpticalTransceiverTxPowerWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module Tx Power value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 11 } + +raisecomOpticalTransceiverTxPowerWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module Tx Power value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 12 } + +raisecomOpticalTransceiverRxPowerAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module Rx Power value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 13 } + +raisecomOpticalTransceiverRxPowerWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module Rx Power value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 14 } + +raisecomOpticalTransceiverRxPowerWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module Rx Power value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 15 } + +raisecomOpticalTransceiverRxPowerAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module Rx Power value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 16 } + +raisecomOpticalTransceiverLaserTemperatureAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module Laser Temperature value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 17 } + +raisecomOpticalTransceiverLaserTemperatureWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module Laser Temperature value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 18 } + +raisecomOpticalTransceiverLaserTemperatureWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module Laser Temperature value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 19 } + +raisecomOpticalTransceiverLaserTemperatureAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module Laser Temperature value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 20 } + +raisecomOpticalTransceiverP5V0supplyVoltageAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module +5.0V supply Voltage value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 21 } + +raisecomOpticalTransceiverP5V0supplyVoltageWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module +5.0V supply Voltage value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 22 } + +raisecomOpticalTransceiverP5V0supplyVoltageWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module +5.0V supply Voltage value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 23 } + +raisecomOpticalTransceiverP5V0supplyVoltageAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module +5.0V supply Voltage value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 24 } + +raisecomOpticalTransceiverP3V3supplyVoltageAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module +3.3V supply Voltage value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 25 } + +raisecomOpticalTransceiverP3V3supplyVoltageWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module +3.3V supply Voltage value increase to above + the high warning threshold or dicrease to under the low warning threshold. + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 26 } + +raisecomOpticalTransceiverP3V3supplyVoltageWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module +3.3V supply Voltage value dicrease to + under the high warning threshold or increase to above the low warning threshold. + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 27 } + +raisecomOpticalTransceiverP3V3supplyVoltageAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module +3.3V supply Voltage value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 28 } + +raisecomOpticalTransceiverP1V8supplyVoltageAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module +1.8v supply Voltage value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 29 } + +raisecomOpticalTransceiverP1V8supplyVoltageWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module +1.8v supply Voltage value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 30 } + +raisecomOpticalTransceiverP1V8supplyVoltageWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module +1.8v supply Voltage value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 31 } + +raisecomOpticalTransceiverP1V8supplyVoltageAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module +1.8v supply Voltage value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 32 } + +raisecomOpticalTransceiverN5V2supplyVoltageAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module -5.2v supply Voltage value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 33 } + +raisecomOpticalTransceiverN5V2supplyVoltageWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module -5.2v supply Voltage value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 34 } + +raisecomOpticalTransceiverN5V2supplyVoltageWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module -5.2v supply Voltage value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 35 } + +raisecomOpticalTransceiverN5V2supplyVoltageAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module -5.2v supply Voltage value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 36 } + +raisecomOpticalTransceiverApdBiasVoltageAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module APD Bias Voltage value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 37 } + +raisecomOpticalTransceiverApdBiasVoltageWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module APD Bias Voltage value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 38 } + +raisecomOpticalTransceiverApdBiasVoltageWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module APD Bias Voltage value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 39 } + +raisecomOpticalTransceiverApdBiasVoltageAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module APD Bias Voltage value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 40 } + +raisecomOpticalTransceiverP5V0supplyCurrentAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module +5.0V supply Current value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 41 } + +raisecomOpticalTransceiverP5V0supplyCurrentWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module +5.0V supply Current value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 42 } + +raisecomOpticalTransceiverP5V0supplyCurrentWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module +5.0V supply Current value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 43 } + +raisecomOpticalTransceiverP5V0supplyCurrentAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module +5.0V supply Current value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 44 } + +raisecomOpticalTransceiverP3V3supplyCurrentAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module +3.3V supply Current value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 45 } + +raisecomOpticalTransceiverP3V3supplyCurrentWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module +3.3V supply Current value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 46 } + +raisecomOpticalTransceiverP3V3supplyCurrentWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module +3.3V supply Current value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 47 } + +raisecomOpticalTransceiverP3V3supplyCurrentAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module +3.3V supply Current value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 48 } + +raisecomOpticalTransceiverP1V8supplyCurrentAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module +1.8V supply Current value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 49 } + +raisecomOpticalTransceiverP1V8supplyCurrentWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module +1.8V supply Current value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 50 } + +raisecomOpticalTransceiverP1V8supplyCurrentWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module +1.8V supply Current value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 51 } + +raisecomOpticalTransceiverP1V8supplyCurrentAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module +1.8V supply Current value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 52 } + +raisecomOpticalTransceiverN5V2supplyCurrentAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module -5.2V supply Current value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 53 } + +raisecomOpticalTransceiverN5V2supplyCurrentWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module -5.2V supply Current value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 54 } + +raisecomOpticalTransceiverN5V2supplyCurrentWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module -5.2V supply Current value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 55 } + +raisecomOpticalTransceiverN5V2supplyCurrentAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module -5.2V supply Current value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 56 } + +raisecomOpticalTransceiverTecCurrentAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module TecCurrent value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 57 } + +raisecomOpticalTransceiverTecCurrentWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module TecCurrent value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 58 } + +raisecomOpticalTransceiverTecCurrentWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module TecCurrent value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 59 } + +raisecomOpticalTransceiverTecCurrentAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module TecCurrent value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 60 } + +raisecomOpticalTransceiverLaserWavelengthAlarmTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + + STATUS current + DESCRIPTION + "This notification is sent when the optical module laserWavelength value increase to above + the high alarm threshold or dicrease to under the low alarm threshold. + + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 61 } + +raisecomOpticalTransceiverLaserWavelengthWarningTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module laserWavelength value increase to above + the high warning threshold or dicrease to under the low warning threshold. + + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 62 } + +raisecomOpticalTransceiverLaserWavelengthWarningNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module laserWavelength value dicrease to + under the high warning threshold or increase to above the low warning threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 63 } + +raisecomOpticalTransceiverLaserWavelengthAlarmNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomNotificationLocation, + raisecomOpticalTransceiverParameterValue, + raisecomOpticalTransceiverParamAlarmStatus } + STATUS current + DESCRIPTION + "This notification is sent when the optical module laserWavelength value dicrease to + under the high alarm threshold or increase to above the low alarm threshold. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 64 } + + raisecomOpticalTransceiverTxFaultTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverTxFaultStatus } + STATUS current + DESCRIPTION + "This notification is sent when the SFP optical module occures Tx-fault signal. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 65 } + + raisecomOpticalTransceiverTxNormalTrap NOTIFICATION-TYPE + OBJECTS { raisecomOpticalTransceiverTxFaultStatus } + STATUS current + DESCRIPTION + "This notification is sent when the SFP optical module cancels the Tx-fault signal. + + This notification may be suppressed under the following + conditions: + - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects. + " + ::={ raisecomOpticalTransceiverParamNotifications 66 } + +END |