summaryrefslogtreecommitdiff
path: root/MIBS/riverbed
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/riverbed')
-rw-r--r--MIBS/riverbed/RBT-MIB18
-rw-r--r--MIBS/riverbed/STEELHEAD-MIB2393
2 files changed, 2411 insertions, 0 deletions
diff --git a/MIBS/riverbed/RBT-MIB b/MIBS/riverbed/RBT-MIB
new file mode 100644
index 0000000..15db990
--- /dev/null
+++ b/MIBS/riverbed/RBT-MIB
@@ -0,0 +1,18 @@
+RBT-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ OBJECT-TYPE, MODULE-IDENTITY, enterprises FROM SNMPv2-SMI;
+
+rbt MODULE-IDENTITY
+ LAST-UPDATED "200604100000Z"
+ ORGANIZATION "Riverbed Technology, Inc."
+ CONTACT-INFO
+ " John Cho
+ jcho@riverbed.com"
+ DESCRIPTION "Riverbed Technology MIB"
+ ::= { enterprises 17163 }
+
+products OBJECT IDENTIFIER
+ ::= { rbt 1 }
+
+END
diff --git a/MIBS/riverbed/STEELHEAD-MIB b/MIBS/riverbed/STEELHEAD-MIB
new file mode 100644
index 0000000..e2daa92
--- /dev/null
+++ b/MIBS/riverbed/STEELHEAD-MIB
@@ -0,0 +1,2393 @@
+STEELHEAD-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Unsigned32,
+ TimeTicks, IpAddress, Counter32, Counter64 FROM SNMPv2-SMI
+ DateAndTime FROM SNMPv2-TC
+ products FROM RBT-MIB;
+
+steelhead MODULE-IDENTITY
+ LAST-UPDATED "201202030000Z"
+ ORGANIZATION "Riverbed Technology, Inc."
+ CONTACT-INFO
+ " Riverbed Technical Support
+ support@riverbed.com"
+ DESCRIPTION "Steelhead MIB"
+ REVISION "201202030000Z"
+ DESCRIPTION "Updated for 7.0.1"
+ ::= { products 1 }
+
+system OBJECT IDENTIFIER
+ ::= { steelhead 1 }
+
+status OBJECT IDENTIFIER
+ ::= { steelhead 2 }
+
+config OBJECT IDENTIFIER
+ ::= { steelhead 3 }
+
+alarms OBJECT IDENTIFIER
+ ::= { steelhead 4 }
+
+statistics OBJECT IDENTIFIER
+ ::= { steelhead 5 }
+
+--
+--
+-- SYSTEM
+--
+--
+
+model OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Appliance model"
+ ::= { system 1 }
+
+serialNumber OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Appliance serial number"
+ ::= { system 2 }
+
+systemVersion OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "System software version string"
+ ::= { system 3 }
+
+
+
+--
+--
+-- STATUS
+--
+--
+
+systemClock OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "System clock time"
+ ::= { status 1 }
+
+health OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current health of the system. The value is one amongst
+ Healthy, Admission Control, Degraded, Critical"
+ ::= { status 2 }
+
+serviceStatus OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current status of the optimization service"
+ ::= { status 3 }
+
+serviceUptime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Uptime of the optimization service"
+ ::= { status 4 }
+
+procTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ProcEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table containing information about the various
+ managed processes"
+ ::= { status 5 }
+
+procEntry OBJECT-TYPE
+ SYNTAX ProcEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for one process"
+ INDEX { procIndex }
+ ::= { procTable 1 }
+
+ProcEntry ::=
+ SEQUENCE {
+ procIndex Unsigned32,
+ procName OCTET STRING,
+ procStatus OCTET STRING,
+ procNumFailures Unsigned32
+ }
+
+procIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Synthetic numeric unique ID of process"
+ ::= { procEntry 1 }
+
+procName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Unique name of process"
+ ::= { procEntry 2 }
+
+procStatus OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current state of process"
+ ::= { procEntry 3 }
+
+procNumFailures OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of times process has crashed or exited unexpectedly"
+ ::= { procEntry 4 }
+
+peerStatus OBJECT IDENTIFIER
+ ::= { status 6 }
+
+peerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PeerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing information about the various peer
+ appliances"
+ ::= { peerStatus 1 }
+
+peerEntry OBJECT-TYPE
+ SYNTAX PeerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for one peer"
+ INDEX { peerIndex }
+ ::= { peerTable 1 }
+
+PeerEntry ::=
+ SEQUENCE {
+ peerIndex Unsigned32,
+ peerHostname OCTET STRING,
+ peerVersion OCTET STRING,
+ peerAddress IpAddress,
+ peerModel OCTET STRING
+ }
+
+peerIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index of peer"
+ ::= { peerEntry 1 }
+
+peerHostname OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Hostname of peer"
+ ::= { peerEntry 2 }
+
+peerVersion OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "System software version of peer"
+ ::= { peerEntry 3 }
+
+peerAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IP address of peer"
+ ::= { peerEntry 4 }
+
+peerModel OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Model of peer"
+ ::= { peerEntry 5 }
+
+systemHealth OBJECT-TYPE
+ SYNTAX INTEGER {
+ healthy (10000),
+ degraded (30000),
+ admissionControl (31000),
+ critical (50000)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current health of the system. This variable is identical to
+ health except that it is of integer datatype"
+ ::= { status 7 }
+
+optServiceStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ none (0),
+ unmanaged (1),
+ running (2),
+ sentCom1 (3),
+ sentTerm1 (4),
+ sentTerm2 (5),
+ sentTerm3 (6),
+ pending (7),
+ stopped (8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of the optimization service. This variable is identical to
+ serviceStatus except that it is of integer datatype"
+ ::= { status 8 }
+
+systemTemperature OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature of the system (C)"
+ ::= { status 9 }
+
+healthNotes OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Some notes regarding the health of the system"
+ ::= { status 10 }
+
+neighborStatus OBJECT IDENTIFIER
+ ::= { status 12 }
+
+neighborTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NeighborEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of neighbors and their status"
+ ::= { neighborStatus 1 }
+
+neighborEntry OBJECT-TYPE
+ SYNTAX NeighborEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for one neighbor"
+ INDEX { neighborIndex }
+ ::= { neighborTable 1 }
+
+NeighborEntry ::=
+ SEQUENCE {
+ neighborIndex Unsigned32,
+ neighborAddress IpAddress,
+ neighborState Unsigned32,
+ neighborNatReqSent Counter32,
+ neighborNatDelSent Counter32,
+ neighborNatAckRcvd Counter32,
+ neighborNatReqRcvd Counter32,
+ neighborNatDelRcvd Counter32,
+ neighborNatAckSent Counter32,
+ neighborDynReqSent Counter32,
+ neighborDynDelSent Counter32,
+ neighborDynAckRcvd Counter32,
+ neighborDynReqRcvd Counter32,
+ neighborDynDelRcvd Counter32,
+ neighborDynAckSent Counter32,
+ neighborRedirReqSent Counter32,
+ neighborRedirDelSent Counter32,
+ neighborRedirAckRcvd Counter32,
+ neighborRedirReqRcvd Counter32,
+ neighborRedirDelRcvd Counter32,
+ neighborRedirAckSent Counter32,
+ neighborConnFailures Counter32,
+ neighborKeepaliveTimeouts Counter32,
+ neighborRequestTimeouts Counter32,
+ neighborMaxLatency Unsigned32
+ }
+
+neighborIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index of neighbor"
+ ::= { neighborEntry 1 }
+
+neighborAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IP address of neighbor"
+ ::= { neighborEntry 2 }
+
+neighborState OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "State of this neighbor"
+ ::= { neighborEntry 3 }
+
+neighborNatReqSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of NAT request messages sent to this neighbor"
+ ::= { neighborEntry 4 }
+
+neighborNatDelSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of NAT DEL messages sent to this neighbor"
+ ::= { neighborEntry 5 }
+
+neighborNatAckRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of NAT ACK messages received from this neighbor"
+ ::= { neighborEntry 6 }
+
+neighborNatReqRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of NAT request messages received from this neighbor"
+ ::= { neighborEntry 7 }
+
+neighborNatDelRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of NAT DEL messages received from this neighbor"
+ ::= { neighborEntry 8 }
+
+neighborNatAckSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of NAT ACK messages sent to this neighbor"
+ ::= { neighborEntry 9 }
+
+neighborDynReqSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of DYN request messages sent to this neighbor"
+ ::= { neighborEntry 10 }
+
+neighborDynDelSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of DYN DEL messages sent to this neighbor"
+ ::= { neighborEntry 11 }
+
+neighborDynAckRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of DYN ACK messages received from this neighbor"
+ ::= { neighborEntry 12 }
+
+neighborDynReqRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of DYN request messages received from this neighbor"
+ ::= { neighborEntry 13 }
+
+neighborDynDelRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of DYN DEL messages received from this neighbor"
+ ::= { neighborEntry 14 }
+
+neighborDynAckSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of DYN ACK messages sent to this neighbor"
+ ::= { neighborEntry 15 }
+
+neighborRedirReqSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of REDIR request messages sent to this neighbor"
+ ::= { neighborEntry 16 }
+
+neighborRedirDelSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of REDIR DEL messages sent to this neighbor"
+ ::= { neighborEntry 17 }
+
+neighborRedirAckRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of REDIR ACK messages received from this neighbor"
+ ::= { neighborEntry 18 }
+
+neighborRedirReqRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of REDIR request messages received from this neighbor"
+ ::= { neighborEntry 19 }
+
+neighborRedirDelRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of REDIR DEL messages received from this neighbor"
+ ::= { neighborEntry 20 }
+
+neighborRedirAckSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of REDIR ACK messages sent to this neighbor"
+ ::= { neighborEntry 21 }
+
+neighborConnFailures OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of connection failures with this neighbor"
+ ::= { neighborEntry 22 }
+
+neighborKeepaliveTimeouts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of keepalives that have timed out with this neighbor"
+ ::= { neighborEntry 23 }
+
+neighborRequestTimeouts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of requests that have timed out with this neighbor"
+ ::= { neighborEntry 24 }
+
+neighborMaxLatency OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum latency that has been seen with this neighbor"
+ ::= { neighborEntry 25 }
+
+neighborAggregates OBJECT IDENTIFIER
+ ::= { neighborStatus 2 }
+
+nghAggrConfigured OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of neighbors configured"
+ ::= { neighborAggregates 1 }
+
+nghAggrConnected OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of neighbors connected"
+ ::= { neighborAggregates 2 }
+
+nghAggrConnFailures OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of connection failures"
+ ::= { neighborAggregates 3 }
+
+nghAggrKeepaliveTimouts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of keepalives that have timed out"
+ ::= { neighborAggregates 4 }
+
+nghAggrRequestTimeouts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of requests that have timed out"
+ ::= { neighborAggregates 5 }
+
+nghAggrMaxLatency OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum latency that had been seen"
+ ::= { neighborAggregates 6 }
+
+nghAggrNatReqSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of NAT request messages sent"
+ ::= { neighborAggregates 7 }
+
+nghAggrNatDelSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of NAT DEL messages sent"
+ ::= { neighborAggregates 8 }
+
+nghAggrNatAckRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of NAT ACK messages received"
+ ::= { neighborAggregates 9 }
+
+nghAggrNatReqRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of NAT request messages received"
+ ::= { neighborAggregates 10 }
+
+nghAggrNatDelRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of NAT DEL messages received"
+ ::= { neighborAggregates 11 }
+
+nghAggrNatAckSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of NAT ACK messages sent"
+ ::= { neighborAggregates 12 }
+
+nghAggrDynReqSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of DYN request messages sent"
+ ::= { neighborAggregates 13 }
+
+nghAggrDynDelSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of DYN DEL messages sent"
+ ::= { neighborAggregates 14 }
+
+nghAggrDynAckRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of DYN ACK messages received"
+ ::= { neighborAggregates 15 }
+
+nghAggrDynReqRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of DYN request messages received"
+ ::= { neighborAggregates 16 }
+
+nghAggrDynDelRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of DYN DEL messages received"
+ ::= { neighborAggregates 17 }
+
+nghAggrDynAckSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of DYN ACK messages sent"
+ ::= { neighborAggregates 18 }
+
+nghAggrRedirReqSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of REDIR request messages sent"
+ ::= { neighborAggregates 19 }
+
+nghAggrRedirDelSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of REDIR DEL messages"
+ ::= { neighborAggregates 20 }
+
+nghAggrRedirAckRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of REDIR ACK messages received"
+ ::= { neighborAggregates 21 }
+
+nghAggrRedirReqRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of REDIR request messages received"
+ ::= { neighborAggregates 22 }
+
+nghAggrRedirDelRcvd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of REDIR DEL messages received"
+ ::= { neighborAggregates 23 }
+
+nghAggrRedirAckSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of REDIR ACK messages sent"
+ ::= { neighborAggregates 24 }
+
+
+crlStatus OBJECT IDENTIFIER
+ ::= { status 11 }
+
+crlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CrlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing information about crl polling of various SSL
+ modules"
+ ::= { crlStatus 1 }
+
+crlEntry OBJECT-TYPE
+ SYNTAX CrlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for crl polling of one SSL module"
+ INDEX { crlIndex }
+ ::= { crlTable 1 }
+
+CrlEntry ::=
+ SEQUENCE {
+ crlIndex Unsigned32,
+ crlFeatureName OCTET STRING,
+ crlNumCdpErr Unsigned32,
+ crlErrMsg OCTET STRING
+ }
+
+crlIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index of one SSL module"
+ ::= { crlEntry 1 }
+
+crlFeatureName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Name of SSL module"
+ ::= { crlEntry 2 }
+
+crlNumCdpErr OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of cdp(s) from which crl polling fails"
+ ::= { crlEntry 3 }
+
+crlErrMsg OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A group of error messages showing failure of cdp(s) polling"
+ ::= { crlEntry 4 }
+
+capabilityStatus OBJECT IDENTIFIER
+ ::= { status 13 }
+
+shMaxConnections OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum possible connections through this appliance"
+ ::= { capabilityStatus 1 }
+
+shMaxBandwidth OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Maximum possible bandwidth for this appliance"
+ ::= { capabilityStatus 2 }
+
+asymRouteCount OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of Asymmetric Routes"
+ ::= { status 14 }
+
+
+
+--
+--
+-- CONFIG
+--
+--
+
+activeConfig OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Name of the currently active configuration"
+ ::= { config 1 }
+
+inpath OBJECT IDENTIFIER
+ ::= { config 2 }
+
+inpathSupport OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "In-path support"
+ ::= { inpath 1 }
+
+outofpath OBJECT IDENTIFIER
+ ::= { config 3 }
+
+outofpathSupport OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Out-of-path support"
+ ::= { outofpath 1 }
+
+datastoreSync OBJECT IDENTIFIER
+ ::= { config 4 }
+
+datastoreSyncPort OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Datastore Sync Port"
+ ::= { datastoreSync 1 }
+
+datastoreSyncAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Datastore Sync Address"
+ ::= { datastoreSync 2 }
+
+
+
+--
+--
+-- ALARMS
+--
+--
+
+alarmsPrefix OBJECT IDENTIFIER
+ ::= { alarms 0 }
+
+procCrash NOTIFICATION-TYPE
+ OBJECTS { procName }
+ STATUS current
+ DESCRIPTION
+ "A procCrash trap signifies that a process managed by PM
+ has crashed and left a core file. The variable sent with
+ the notification indicates which process crashed."
+ ::= { alarmsPrefix 1 }
+
+procExit NOTIFICATION-TYPE
+ OBJECTS { procName }
+ STATUS current
+ DESCRIPTION
+ "A procExit trap signifies that a process managed by PM
+ has exited unexpectedly, but not left a core file.
+
+ The variable sent with the notification indicates
+ which process exited."
+ ::= { alarmsPrefix 2 }
+
+cpuUtil NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The average CPU utilization in the past minute has gone
+ above the acceptable threshold"
+ ::= { alarmsPrefix 3 }
+
+pagingActivity NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The system has been paging excessively (thrashing)"
+ ::= { alarmsPrefix 4 }
+
+smartError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "SMART has sent an event about a possible disk error"
+ ::= { alarmsPrefix 5 }
+
+peerVersionMismatch NOTIFICATION-TYPE
+ OBJECTS { systemVersion }
+ STATUS current
+ DESCRIPTION
+ "Detected a peer with a mismatched software version"
+ ::= { alarmsPrefix 6 }
+
+bypassMode NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Traffic is being passed through"
+ ::= { alarmsPrefix 7 }
+
+raidError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "An error has been generated by the RAID array"
+ ::= { alarmsPrefix 8 }
+
+storeCorruption NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The data store is corrupted"
+ ::= { alarmsPrefix 9 }
+
+admissionMemError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Memory pressure is high. No additional connections will be
+ optimized"
+ ::= { alarmsPrefix 10 }
+
+admissionConnError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Connection limit reached. No additional connections will be
+ optimized"
+ ::= { alarmsPrefix 11 }
+
+haltError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The service is halted due to a software error"
+ ::= { alarmsPrefix 12 }
+
+serviceError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "There has been a non-fatal optimization service error.
+ Please consult the log file"
+ ::= { alarmsPrefix 13 }
+
+scheduledJobError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A scheduled job has failed during execution"
+ ::= { alarmsPrefix 14 }
+
+confModeEnter NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A user has entered configuration mode"
+ ::= { alarmsPrefix 15 }
+
+confModeExit NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A user has exited configuration mode"
+ ::= { alarmsPrefix 16 }
+
+linkError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "An interface on the appliance has lost its link"
+ ::= { alarmsPrefix 17 }
+
+nfsV2V4 NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "NFS v2/v4 alarm notification"
+ ::= { alarmsPrefix 18 }
+
+powerSupplyError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A power supply on the appliance has failed" -- Not supported on all models
+ ::= { alarmsPrefix 19 }
+
+asymRouteError NOTIFICATION-TYPE
+ OBJECTS { asymRouteCount }
+ STATUS current
+ DESCRIPTION
+ "Asymmetric routes have been detected,certain connections might
+ not have been optimized because of this."
+ ::= { alarmsPrefix 20 }
+
+fanError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A fan has failed on this appliance" -- Not supported on all models
+ ::= { alarmsPrefix 21 }
+
+memoryError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A memory error has been detected on the appliance" -- Not supported on all models
+ ::= { alarmsPrefix 22 }
+
+ipmi NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "An IPMI event has been detected on the appliance. Please check
+ the details in the alarm report on the web UI" -- Not supported on all models
+ ::= { alarmsPrefix 23 }
+
+configChange NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A change has been made to the system's configuration"
+ ::= { alarmsPrefix 24 }
+
+datastoreWrapped NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The datastore has wrapped around"
+ ::= { alarmsPrefix 25 }
+
+temperatureWarning NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The system temperature has exceeded the threshold"
+ ::= { alarmsPrefix 26 }
+
+temperatureCritical NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The system temperature has reached a critical stage"
+ ::= { alarmsPrefix 27 }
+
+cfConnFailure NOTIFICATION-TYPE
+ OBJECTS { neighborAddress }
+ STATUS current
+ DESCRIPTION
+ "Unable to establish connection with the specified neighbor"
+ ::= { alarmsPrefix 28 }
+
+cfConnLostEos NOTIFICATION-TYPE
+ OBJECTS { neighborAddress }
+ STATUS current
+ DESCRIPTION
+ "Connection lost since end of stream was received from the
+ specified neighbor"
+ ::= { alarmsPrefix 29 }
+
+cfConnLostErr NOTIFICATION-TYPE
+ OBJECTS { neighborAddress }
+ STATUS current
+ DESCRIPTION
+ "Connection lost due to an error communicating with the
+ specified neighbor"
+::= { alarmsPrefix 30 }
+
+cfKeepaliveTimeout NOTIFICATION-TYPE
+ OBJECTS { neighborAddress }
+ STATUS current
+ DESCRIPTION
+ "Connection lost due to lack of keepalives from the specified
+ neighbor"
+ ::= { alarmsPrefix 31 }
+
+cfAckTimeout NOTIFICATION-TYPE
+ OBJECTS { neighborAddress }
+ STATUS current
+ DESCRIPTION
+ "Connection lost due to lack of acks from the specified
+ neighbor"
+ ::= { alarmsPrefix 32 }
+
+cfReadInfoTimeout NOTIFICATION-TYPE
+ OBJECTS { neighborAddress }
+ STATUS current
+ DESCRIPTION
+ "Timeout reading info from the specified neighbor"
+ ::= { alarmsPrefix 33 }
+
+cfLatencyExceeded NOTIFICATION-TYPE
+ OBJECTS { neighborAddress }
+ STATUS current
+ DESCRIPTION
+ "Connection forwarding latency with the specified neighbor
+ has exceeded the threshold"
+ ::= { alarmsPrefix 34 }
+
+sslPeeringSCEPAutoReenrollError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "There is an error in the automatic re-enrollment of the SSL peering certificate"
+ ::= { alarmsPrefix 35 }
+
+crlError NOTIFICATION-TYPE
+ OBJECTS { crlFeatureName, crlErrMsg }
+ STATUS current
+ DESCRIPTION
+ "crl polling fails"
+ ::= { alarmsPrefix 36 }
+
+datastoreSyncFailure NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Data store sync has failed"
+ ::= { alarmsPrefix 37 }
+
+secureVaultNeedsUnlock NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "SSL acceleration and the secure data store cannot be used until
+ the secure vault has been unlocked."
+ ::= { alarmsPrefix 38 }
+
+secureVaultNeedsRekey NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "If you wish to use a non-default password for the secure
+ vault, the password must be rekeyed. Please see
+ Knowledge Base article 5592 for more details."
+ ::= { alarmsPrefix 39 }
+
+secureVaultInitError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "An error was detected while initializing
+ the secure vault. Please contact customer support."
+ ::= { alarmsPrefix 40 }
+
+configSave NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The current appliance configuration has been saved"
+ ::= { alarmsPrefix 41 }
+
+tcpDumpStarted NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A TCP Dump has been started"
+ ::= { alarmsPrefix 42 }
+
+tcpDumpScheduled NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A TCP Dump has been scheduled"
+ ::= { alarmsPrefix 43 }
+
+newUserCreated NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A new user has been created"
+ ::= { alarmsPrefix 44 }
+
+diskError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Disk error has been detected"
+ ::= { alarmsPrefix 45 }
+
+wearWarning NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Accumulated SSD write cycles passed predefined level"
+ ::= { alarmsPrefix 46 }
+
+cliUserLogin NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A user has just logged-in via CLI"
+ ::= { alarmsPrefix 47 }
+
+cliUserLogout NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A CLI user has just logged-out"
+ ::= { alarmsPrefix 48 }
+
+webUserLogin NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A user has just logged-in via the Web UI"
+ ::= { alarmsPrefix 49 }
+
+webUserLogout NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A user has just logged-out via the Web UI"
+ ::= { alarmsPrefix 50 }
+
+trapTest NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Trap test"
+ ::= { alarmsPrefix 51 }
+
+admissionCpuError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Optimization service is experiencing high CPU utilization, no additional
+ connections will be optimized"
+ ::= { alarmsPrefix 52 }
+
+admissionTcpError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Optimization service is experiencing high TCP memory pressure, no additional
+ connections will be optimized"
+ ::= { alarmsPrefix 53 }
+
+systemDiskFullError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "One or more system partitions is full or almost full"
+ ::= { alarmsPrefix 54 }
+
+domainJoinError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "An attempt to join a domain failed"
+ ::= { alarmsPrefix 55 }
+
+certsExpiringError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Some x509 certificates may be expiring"
+ ::= { alarmsPrefix 56 }
+
+licenseError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The main Appliance license has expired, been removed, or become invalid"
+ ::= { alarmsPrefix 57 }
+
+hardwareError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Hardware Error detected"
+ ::= { alarmsPrefix 58 }
+
+sysdetailError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Error is found in System Detail Report"
+ ::= { alarmsPrefix 59 }
+
+admissionMapiError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "New MAPI connections will be passed through due to high connection count"
+ ::= { alarmsPrefix 60 }
+
+neighborIncompatibility NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Serial cascade misconfiguration has been detected"
+ ::= { alarmsPrefix 61 }
+
+flashError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Flash hardware error detected."
+ ::= { alarmsPrefix 62 }
+
+lanWanLoopError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "LAN-WAN loop detected. System will not optimize new connections un
+till this error is cleared"
+ ::= { alarmsPrefix 63 }
+
+optimizationServiceStatusError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Optimization service currently not optimizing any connecntions."
+ ::= { alarmsPrefix 64 }
+
+upgradeFailure NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Upgrade failed and the system is running the previous image"
+ ::= { alarmsPrefix 65 }
+
+licenseExpiring NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "One or more licensed features will expire within the next two week
+s"
+ ::= { alarmsPrefix 66 }
+
+licenseExpired NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "One or more licensed features have expired"
+ ::= { alarmsPrefix 67 }
+
+clusterDisconnectedSHAlertError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A cluster Steelhead has been reported as disconnected"
+ ::= { alarmsPrefix 68 }
+
+smbAlert NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Domain authentication alert"
+ ::= { alarmsPrefix 69 }
+
+linkDuplex NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "An interface on the appliance is in half-duplex mode"
+ ::= { alarmsPrefix 70 }
+
+linkIoErrors NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "An interface on the appliance is suffering I/O errors"
+ ::= { alarmsPrefix 71 }
+
+storageProfSwitchFailed NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Storage profile switch failed"
+ ::= { alarmsPrefix 73 }
+
+cpuUtilClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The average CPU utilization has fallen back
+ within the acceptable threshold"
+ ::= { alarmsPrefix 1003 }
+
+pagingActivityClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The system has stopped paging excessively (thrashing)"
+ ::= { alarmsPrefix 1004 }
+
+peerVersionMismatchClear NOTIFICATION-TYPE
+ OBJECTS { systemVersion }
+ STATUS current
+ DESCRIPTION
+ "All peers are compatible"
+ ::= { alarmsPrefix 1006 }
+
+bypassModeClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Traffic is now being optimized"
+ ::= { alarmsPrefix 1007 }
+
+raidErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A RAID error has been cleared"
+ ::= { alarmsPrefix 1008 }
+
+storeCorruptionClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The data store is normal"
+ ::= { alarmsPrefix 1009 }
+
+admissionMemErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Admission control memory alarm has been cleared,
+ and the optimization service is running normally"
+ ::= { alarmsPrefix 1010 }
+
+admissionConnErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Admission control connections alarm has been cleared,
+ and the service is running normally"
+ ::= { alarmsPrefix 1011 }
+
+haltErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The service is now running normally"
+ ::= { alarmsPrefix 1012 }
+
+serviceErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The service is now running normally"
+ ::= { alarmsPrefix 1013 }
+
+linkErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "An interface on the appliance has regained its link"
+ ::= { alarmsPrefix 1017 }
+
+nfsV2V4Clear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "NFS v2/v4 alarm has been cleared"
+ ::= { alarmsPrefix 1018 }
+
+powerSupplyErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "All power supplies are now functioning normally" -- Not supported on all models
+ ::= { alarmsPrefix 1019 }
+
+asymRouteErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "All asymmetric routes have expired or have been cleared"
+ ::= { alarmsPrefix 1020 }
+
+fanErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "All system fans are now functioning normally" -- Not supported on all models
+ ::= { alarmsPrefix 1021 }
+
+memoryErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A memory error has been rectified on the appliance" -- Not supported on all models
+ ::= { alarmsPrefix 1022 }
+
+ipmiClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "An IPMI event has been rectified on the appliance" -- Not supported on all models
+ ::= { alarmsPrefix 1023 }
+
+temperatureNormal NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The system temperature is back within the threshold"
+ ::= { alarmsPrefix 1026 }
+
+temperatureNonCritical NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The system temperature is no longer in a critical stage"
+ ::= { alarmsPrefix 1027 }
+
+cfConnRestored NOTIFICATION-TYPE
+ OBJECTS { neighborAddress }
+ STATUS current
+ DESCRIPTION
+ "Connection reestablished with the specified neighbor"
+ ::= { alarmsPrefix 1028 }
+
+cfConnLostEosClear NOTIFICATION-TYPE
+ OBJECTS { neighborAddress }
+ STATUS current
+ DESCRIPTION
+ "Connection restablished after a prior termination due to
+ receiving end of strem from the specified neighbor"
+ ::= { alarmsPrefix 1029 }
+
+cfConnLostErrClear NOTIFICATION-TYPE
+ OBJECTS { neighborAddress }
+ STATUS current
+ DESCRIPTION
+ "Connection restablished after a prior termination due to
+ an error communicating with the specified neighbor"
+ ::= { alarmsPrefix 1030 }
+
+cfKeepaliveTimeoutClear NOTIFICATION-TYPE
+ OBJECTS { neighborAddress }
+ STATUS current
+ DESCRIPTION
+ "Keepalive restored after a prior timeout with the specified neighbor"
+ ::= { alarmsPrefix 1031 }
+
+cfAckTimeoutClear NOTIFICATION-TYPE
+ OBJECTS { neighborAddress }
+ STATUS current
+ DESCRIPTION
+ "Ack restored after a prior timeout with the specified neighbor"
+ ::= { alarmsPrefix 1032 }
+
+cfReadInfoTimeoutClear NOTIFICATION-TYPE
+ OBJECTS { neighborAddress }
+ STATUS current
+ DESCRIPTION
+ "Successfully read info from the specified neighbor after a prior
+ timeout"
+ ::= { alarmsPrefix 1033 }
+
+cfLatencyExceededClear NOTIFICATION-TYPE
+ OBJECTS { neighborAddress }
+ STATUS current
+ DESCRIPTION
+ "Connection forwarding latency with the specified neighbor
+ is back within the threshold"
+ ::= { alarmsPrefix 1034 }
+
+sslPeeringSCEPAutoReenrollClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Automatic re-enrollment of SSL peering certificate is OK or is disabled"
+ ::= { alarmsPrefix 1035 }
+
+crlClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "crl polling is running normally"
+ ::= { alarmsPrefix 1036 }
+
+datastoreSyncFailureClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Data store sync restored"
+ ::= { alarmsPrefix 1037 }
+
+secureVaultClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Secure vault has been unlocked and is healthy"
+ ::= { alarmsPrefix 1040 }
+
+diskErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "All disks are back online"
+ ::= { alarmsPrefix 1045 }
+
+admissionCpuErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Admission control CPU alarm has been cleared,
+ and the service is running normally"
+ ::= { alarmsPrefix 1052 }
+
+admissionTcpErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Admission control TCP alarm has been cleared,
+ and the service is running normally"
+ ::= { alarmsPrefix 1053 }
+
+systemDiskFullErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The system partitions are below usage thresholds"
+ ::= { alarmsPrefix 1054 }
+
+domainJoinErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "A domain error on the appliance has been cleared"
+ ::= { alarmsPrefix 1055 }
+
+certsExpiringErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "There are no expiring certificates"
+ ::= { alarmsPrefix 1056 }
+
+licenseErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "The main appliance license error has been cleared"
+ ::= { alarmsPrefix 1057 }
+
+hardwareErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Hardware Error has been cleared"
+ ::= { alarmsPrefix 1058 }
+
+sysdetailErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Overall status of System Detail Report is back to OK"
+ ::= { alarmsPrefix 1059 }
+
+admissionMapiErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "System will resume to optimize new MAPI connections since connection count has fallen below the threshold"
+ ::= { alarmsPrefix 1060 }
+
+neighborIncompatibilityClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Serial cascade misconfiguration issue is now resolved."
+ ::= { alarmsPrefix 1061 }
+
+flashErrorClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Flash is back to OK."
+ ::= { alarmsPrefix 1062 }
+
+lanWanLoopClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "LAN-WAN loop error cleared. System will resume to optimize connect
+ions."
+ ::= { alarmsPrefix 1063 }
+
+optimizationServiceStatusClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Optimization Service error cleared. System will resume to optimize
+ connections."
+ ::= { alarmsPrefix 1064 }
+
+upgradeFailureClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Upgrade failure cleared and the system is still running
+ the previous image"
+ ::= { alarmsPrefix 1065 }
+
+clusterDisconnectedSHAlertClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "All cluster Steelheads are currently connected"
+ ::= { alarmsPrefix 1068 }
+
+smbAlertClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Domain authentication alert has been cleared"
+ ::= { alarmsPrefix 1069 }
+
+linkDuplexClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "An interface on the appliance has cleared the half-duplex error"
+ ::= { alarmsPrefix 1070 }
+
+linkIoErrorsClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "An interface on the appliance has cleared the I/O errors state"
+ ::= { alarmsPrefix 1071 }
+
+
+
+
+rspGeneralError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "RSP general alarm is triggered."
+ ::= { alarmsPrefix 20001 }
+
+rspServiceError NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "RSP service alarm is triggered."
+ ::= { alarmsPrefix 20002 }
+
+rspGeneralClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "RSP general alarm cleared."
+ ::= { alarmsPrefix 21001 }
+
+rspServiceClear NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "RSP service alarm cleared."
+ ::= { alarmsPrefix 21002 }
+
+
+--
+--
+-- STATISTICS
+--
+--
+
+cpuLoad OBJECT IDENTIFIER
+ ::= { statistics 1 }
+
+cpuLoad1 OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "One-minute CPU load in hundreths"
+ ::= { cpuLoad 1 }
+
+cpuLoad5 OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Five-minute CPU load in hundreths"
+ ::= { cpuLoad 2 }
+
+cpuLoad15 OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Fifteen-minute CPU load in hundreths"
+ ::= { cpuLoad 3 }
+
+cpuUtil1 OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Percentage CPU utilization, aggregated across all CPUs, rolling
+ average over the past minute"
+ ::= { cpuLoad 4 }
+
+cpuIndivUtilTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CPUIndivUtilEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Details about the individual CPU utilization"
+ ::= { cpuLoad 5 }
+
+cpuIndivUtilEntry OBJECT-TYPE
+ SYNTAX CPUIndivUtilEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for one cpu"
+ INDEX { cpuIndivIndex }
+ ::= {cpuIndivUtilTable 1 }
+
+CPUIndivUtilEntry ::=
+ SEQUENCE {
+ cpuIndivIndex Unsigned32,
+ cpuIndivId Unsigned32,
+ cpuIndivIdleTime Unsigned32,
+ cpuIndivSystemTime Unsigned32,
+ cpuIndivUserTime Unsigned32
+}
+
+cpuIndivIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A synthetic number numbering the cpus"
+ ::= { cpuIndivUtilEntry 1 }
+
+cpuIndivId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Name of the cpu, also serves as the Index for the table"
+ ::= { cpuIndivUtilEntry 2 }
+
+cpuIndivIdleTime OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Idle time for this CPU"
+ ::= { cpuIndivUtilEntry 3 }
+
+cpuIndivSystemTime OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "System time for this CPU"
+ ::= { cpuIndivUtilEntry 4 }
+
+cpuIndivUserTime OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "User time for this CPU"
+ ::= { cpuIndivUtilEntry 5 }
+
+connectionCounts OBJECT IDENTIFIER
+ ::= { statistics 2 }
+
+optimizedConnections OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current total number of optimized connections"
+ ::= { connectionCounts 1 }
+
+passthroughConnections OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current total number of pass-through connections"
+ ::= { connectionCounts 2 }
+
+halfOpenedConnections OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current total number of half-opened (optimized) connections"
+ ::= { connectionCounts 3 }
+
+halfClosedConnections OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current total number of half-closed (optimized) connections"
+ ::= { connectionCounts 4 }
+
+establishedConnections OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current number of established (optimized) connections"
+ ::= { connectionCounts 5 }
+
+activeConnections OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Current number of active (optimized) connections"
+ ::= { connectionCounts 6 }
+
+totalConnections OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of connections"
+ ::= { connectionCounts 7 }
+
+bandwidth OBJECT IDENTIFIER
+ ::= { statistics 3 }
+
+bandwidthAggregate OBJECT IDENTIFIER
+ ::= { bandwidth 1 }
+
+bwAggInLan OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total optimized bytes across all application ports, in the
+ WAN to LAN direction since the last restart of service,
+ as measured on the LAN side"
+ ::= { bandwidthAggregate 1 }
+
+bwAggInWan OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total optimized bytes across all application ports, in the
+ WAN to LAN direction since the last restart of service,
+ as measured on the WAN side"
+ ::= { bandwidthAggregate 2 }
+
+bwAggOutLan OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total optimized bytes across all application ports, in the
+ LAN to WAN direction since the last restart of service,
+ as measured on the LAN side"
+ ::= { bandwidthAggregate 3 }
+
+bwAggOutWan OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total optimized bytes across all application ports, in the
+ LAN to WAN direction since the last restart of service,
+ as measured on the WAN side"
+ ::= { bandwidthAggregate 4 }
+
+bandwidthPerPort OBJECT IDENTIFIER
+ ::= { bandwidth 2 }
+
+bwPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BWPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing statistics for optimized traffic on
+ a per application port basis"
+ ::= { bandwidthPerPort 1 }
+
+bwPortEntry OBJECT-TYPE
+ SYNTAX BWPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for one port"
+ INDEX { bwPortNumber }
+ ::= { bwPortTable 1 }
+
+BWPortEntry ::=
+ SEQUENCE {
+ bwPortNumber Unsigned32,
+ bwPortInLan Counter32,
+ bwPortInWan Counter32,
+ bwPortOutLan Counter32,
+ bwPortOutWan Counter32
+ }
+
+bwPortNumber OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Port Number on which the traffic is observed"
+ ::= { bwPortEntry 1 }
+
+bwPortInLan OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Optimized bytes in the WAN to LAN direction since last restart of
+ service, as measured on the LAN side"
+ ::= { bwPortEntry 2 }
+
+bwPortInWan OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Optimized bytes in the WAN to LAN direction since last restart of
+ service, as measured on the WAN side"
+ ::= { bwPortEntry 3 }
+
+bwPortOutLan OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Optimized bytes in the LAN to WAN direction since last restart of
+ service, as measured on the LAN side"
+ ::= { bwPortEntry 4 }
+
+bwPortOutWan OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Optimized bytes in the LAN to WAN direction since last restart of
+ service, as measured on the WAN side"
+ ::= { bwPortEntry 5 }
+
+bandwidthPassThrough OBJECT IDENTIFIER
+ ::= { bandwidth 3 }
+
+bwPassThroughIn OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Passthrough bytes in WAN to LAN direction"
+ ::= { bandwidthPassThrough 1 }
+
+bwPassThroughOut OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Passthrough bytes in LAN to WAN direction"
+ ::= { bandwidthPassThrough 2 }
+
+bwPassThroughTotal OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total passthrough bytes"
+ ::= { bandwidthPassThrough 3 }
+
+datastore OBJECT IDENTIFIER
+ ::= { statistics 4 }
+
+dsHitsTotal OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of datastore hits since last restart of service"
+ ::= { datastore 1 }
+
+dsMissTotal OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of datastore misses since last restart of service"
+ ::= { datastore 2 }
+
+dsCostPerSegment OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "Cost per segment expressed in microseconds"
+ ::= { datastore 3 }
+
+dsAveDiskUtilization OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Average disk utilization, a more accurate measurement of
+ the underlying disk activities, and correlates directly
+ to disk pressure"
+ ::= { datastore 4 }
+
+topTalkers OBJECT IDENTIFIER
+ ::= { statistics 5 }
+
+ttTalkersTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TalkersEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing the top talkers"
+ ::= { topTalkers 1 }
+
+ttTalkersEntry OBJECT-TYPE
+ SYNTAX TalkersEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for one talker"
+ INDEX { ttTalkerId }
+ ::= { ttTalkersTable 1 }
+
+TalkersEntry ::=
+ SEQUENCE {
+ ttTalkerId Unsigned32,
+ ttTalkerIp1 IpAddress,
+ ttTalkerPort1 Unsigned32,
+ ttTalkerIp2 IpAddress,
+ ttTalkerPort2 Unsigned32,
+ ttTalkerByteCount Counter64
+}
+
+ttTalkerId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A synthetic index for the table"
+ ::= { ttTalkersEntry 1 }
+
+ttTalkerIp1 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ip address of end point #1 of this conversaition"
+ ::= { ttTalkersEntry 2 }
+
+ttTalkerPort1 OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Application port for end point #1 of this conversation"
+ ::= { ttTalkersEntry 3 }
+
+ttTalkerIp2 OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ip address of end point #2 of this conversaition"
+ ::= { ttTalkersEntry 4 }
+
+ttTalkerPort2 OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Application port for end point #2 of this conversation"
+ ::= { ttTalkersEntry 5 }
+
+ttTalkerByteCount OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The bidirectional bytecount for this conversation"
+ ::= { ttTalkersEntry 6 }
+
+ttSrcHostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SrcHostEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing the hosts generating the most traffic"
+ ::= { topTalkers 2 }
+
+ttSrcHostEntry OBJECT-TYPE
+ SYNTAX SrcHostEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for one source host"
+ INDEX { ttSrcHostId }
+ ::= { ttSrcHostTable 1 }
+
+SrcHostEntry ::=
+ SEQUENCE {
+ ttSrcHostId Unsigned32,
+ ttSrcHostIp IpAddress,
+ ttSrcHostByteCount Counter64
+}
+
+ttSrcHostId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A synthetic index for the table"
+ ::= { ttSrcHostEntry 1 }
+
+ttSrcHostIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ip address of the host generating the traffic"
+ ::= { ttSrcHostEntry 2 }
+
+ttSrcHostByteCount OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The bytecount of traffic generated by this host "
+ ::= { ttSrcHostEntry 3 }
+
+ttDestHostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DestHostEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing the hosts receiving the most traffic"
+ ::= { topTalkers 3 }
+
+ttDestHostEntry OBJECT-TYPE
+ SYNTAX DestHostEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for one destination host"
+ INDEX { ttDestHostId }
+ ::= { ttDestHostTable 1 }
+
+DestHostEntry ::=
+ SEQUENCE {
+ ttDestHostId Unsigned32,
+ ttDestHostIp IpAddress,
+ ttDestHostByteCount Counter64
+}
+
+ttDestHostId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A synthetic index for the table"
+ ::= { ttDestHostEntry 1 }
+
+ttDestHostIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Ip address of the host receiving the traffic"
+ ::= { ttDestHostEntry 2 }
+
+ttDestHostByteCount OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The bytecount of traffic received by this host "
+ ::= { ttDestHostEntry 3 }
+
+ttAppPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AppPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing the application ports generating
+ the most traffic"
+ ::= { topTalkers 4 }
+
+ttAppPortEntry OBJECT-TYPE
+ SYNTAX AppPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for one application port"
+ INDEX { ttAppPortId }
+ ::= { ttAppPortTable 1 }
+
+AppPortEntry ::=
+ SEQUENCE {
+ ttAppPortId Unsigned32,
+ ttAppPort Unsigned32,
+ ttAppPortByteCount Counter64
+}
+
+ttAppPortId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A synthetic index for the table"
+ ::= { ttAppPortEntry 1 }
+
+ttAppPort OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Port number in the source port field of the traffic"
+ ::= { ttAppPortEntry 2 }
+
+ttAppPortByteCount OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The bytecount of traffic generated with this port
+ number in the source port field"
+ ::= { ttAppPortEntry 3 }
+
+bandwidthHC OBJECT IDENTIFIER
+ ::= { statistics 6 }
+
+bandwidthHCAggregate OBJECT IDENTIFIER
+ ::= { bandwidthHC 1 }
+
+bwHCAggInLan OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total optimized bytes across all application ports, in the
+ WAN to LAN direction since the last restart of service,
+ as measured on the LAN side"
+ ::= { bandwidthHCAggregate 1 }
+
+bwHCAggInWan OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total optimized bytes across all application ports, in the
+ WAN to LAN direction since the last restart of service,
+ as measured on the WAN side"
+ ::= { bandwidthHCAggregate 2 }
+
+bwHCAggOutLan OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total optimized bytes across all application ports, in the
+ LAN to WAN direction since the last restart of service,
+ as measured on the LAN side"
+ ::= { bandwidthHCAggregate 3 }
+
+bwAggHCOutWan OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total optimized bytes across all application ports, in the
+ LAN to WAN direction since the last restart of service,
+ as measured on the WAN side"
+ ::= { bandwidthHCAggregate 4 }
+
+bandwidthHCPerPort OBJECT IDENTIFIER
+ ::= { bandwidthHC 2 }
+
+bwHCPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BWHCPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing statistics for optimized traffic on
+ a per application port basis"
+ ::= { bandwidthHCPerPort 1 }
+
+bwHCPortEntry OBJECT-TYPE
+ SYNTAX BWHCPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Entry for one port"
+ INDEX { bwHCPortNumber }
+ ::= { bwHCPortTable 1 }
+
+BWHCPortEntry ::=
+ SEQUENCE {
+ bwHCPortNumber Unsigned32,
+ bwHCPortInLan Counter64,
+ bwHCPortInWan Counter64,
+ bwHCPortOutLan Counter64,
+ bwHCPortOutWan Counter64
+ }
+
+bwHCPortNumber OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Port Number on which the traffic is observed"
+ ::= { bwHCPortEntry 1 }
+
+bwHCPortInLan OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Optimized bytes in the WAN to LAN direction since last restart of
+ service, as measured on the LAN side"
+ ::= { bwHCPortEntry 2 }
+
+bwHCPortInWan OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Optimized bytes in the WAN to LAN direction since last restart of
+ service, as measured on the WAN side"
+ ::= { bwHCPortEntry 3 }
+
+bwHCPortOutLan OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Optimized bytes in the LAN to WAN direction since last restart of
+ service, as measured on the LAN side"
+ ::= { bwHCPortEntry 4 }
+
+bwHCPortOutWan OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Optimized bytes in the LAN to WAN direction since last restart of
+ service, as measured on the WAN side"
+ ::= { bwHCPortEntry 5 }
+
+
+
+END
+