diff options
Diffstat (limited to 'MIBS/saf/SAF-INTEGRAE-MIB')
| -rw-r--r-- | MIBS/saf/SAF-INTEGRAE-MIB | 2187 |
1 files changed, 2187 insertions, 0 deletions
diff --git a/MIBS/saf/SAF-INTEGRAE-MIB b/MIBS/saf/SAF-INTEGRAE-MIB new file mode 100644 index 0000000..0497694 --- /dev/null +++ b/MIBS/saf/SAF-INTEGRAE-MIB @@ -0,0 +1,2187 @@ +SAF-INTEGRAE-MIB DEFINITIONS ::= BEGIN + +-- Definitions for include by other SAF Tehnika mib modules + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32, Counter64, + TimeTicks + FROM SNMPv2-SMI -- [RFC2578] + pointToPoint + FROM SAF-ENTERPRISE + DateAndTime, TEXTUAL-CONVENTION + FROM SNMPv2-TC + DisplayString, PhysAddress + FROM RFC1213-MIB + safIntegra + FROM SAF-INTEGRA-MIB + OBJECT-GROUP, MODULE-COMPLIANCE + FROM SNMPv2-CONF -- [RFC2580] + IpAddress + FROM SNMPv2-SMI -- [RFC2578] + IANAifType + FROM IANAifType-MIB; + +-- saf OBJECT IDENTIFIER ::= { enterprises 7571 } +-- microwaveRadio OBJECT IDENTIFIER ::= { tehnika 1 } +-- pointToPoint OBJECT IDENTIFIER ::= { microwaveRadio 1 } +-- safIntegra OBJECT IDENTIFIER ::= { pointToPoint 7 } + +integraE MODULE-IDENTITY + LAST-UPDATED "202004250000Z" -- 25 apr 2020 + ORGANIZATION "SAF Tehnika" + CONTACT-INFO + "SAF Tehnika technical support + <techsupport@saftehnika.com>" + DESCRIPTION + "SAF Integra-E device management base" +-- Revision history + REVISION "202004250000Z" -- 25 apr 2020 + DESCRIPTION + "ACMB min/max modem modulation read-only support" + REVISION "202004220000Z" -- 22 apr 2020 + DESCRIPTION + "ATPC read-only support" + REVISION "202001140000Z" -- 14 jan 2020 + DESCRIPTION + "Added LSP/Backup port status." + REVISION "201911210000Z" -- 21 nov 2019 + DESCRIPTION + "Added system service sensors." + REVISION "201906110000Z" -- 11 jun 2019 + DESCRIPTION + "Added device fan error status." + REVISION "201904230000Z" -- 23 apr 2019 + DESCRIPTION + "Added device type, serial number and product code." + REVISION "201903120000Z" -- 12 mar 2019 + DESCRIPTION + "Changed integraEifPortSpeed to integraEifPortHighSpeed, that will use Mbps instead of bps." + REVISION "201902040000Z" -- 04 feb 2019 + DESCRIPTION + "FEC load parameter type changed to Integer32" + REVISION "201811150000Z" -- 15 nov 2018 + DESCRIPTION + "FEC locked modem parameter added" + REVISION "201811140000Z" -- 14 nov 2018 + DESCRIPTION + "Public Release 1.0" + ::= { safIntegra 9 } + + + +FixedDiv20 ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d-2" + STATUS current + DESCRIPTION "Fixed point, two decimals" + SYNTAX Integer32 + +FixedDiv10 ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d-1" + STATUS current + DESCRIPTION "Fixed point, two decimals" + SYNTAX Integer32 + + + +integraEtimestamp OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Last data update time" + ::= { integraE 1 } + +integraEradio OBJECT IDENTIFIER ::= { integraE 2 } + +integraEradioTxPower OBJECT-TYPE + SYNTAX Integer32 + UNITS "dBm" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Output power of radio transmitter" + ::= { integraEradio 1 } + +integraEradioTxFrequency OBJECT-TYPE + SYNTAX Integer32 + UNITS "kHz" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Frequency of radio transmitter" + ::= { integraEradio 2 } + +integraEradioRxLevel OBJECT-TYPE + SYNTAX Integer32 + UNITS "dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Level of the received signal" + ::= { integraEradio 3 } + +integraEradioSide OBJECT-TYPE + SYNTAX INTEGER { + high(1), + low(2), + error(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Radio side: Low/High" + ::= { integraEradio 4 } + +integraEradioTxMute OBJECT-TYPE + SYNTAX INTEGER { + on(1), + off(2), + error(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Status of 'Tx mute' + 1 - Tx is muted, + 2 - Tx is not muted. + 3 - Status information unavailable" + ::= { integraEradio 5 } + +integraEradioDuplexShift OBJECT-TYPE + SYNTAX Integer32 + UNITS "kHz" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Utilized duplex shift in kHz" + ::= { integraEradio 6 } + +integraEradioRxFrequency OBJECT-TYPE + SYNTAX Integer32 + UNITS "kHz" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Frequency of radio receiver" + ::= { integraEradio 7 } + +integraEradioTemperature OBJECT-TYPE + SYNTAX FixedDiv10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Radio module temperature" + ::= { integraEradio 8 } + +integraEradioTxMuteDuration OBJECT-TYPE + SYNTAX Integer32(0..214748364) + UNITS "s" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Time remaning for Tx to be muted in seconds. + To turn mute on send number of seconds between 10 and MAX. + To turn mute off send 0. + GET will retrieve remaining duration for mute or + 0 if Tx mute is turned off." + ::= { integraEradio 9 } + +--Settable radio parameter range values + +integraEradioRangesTable OBJECT-TYPE + SYNTAX SEQUENCE OF IntegraEradioRangeEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Network interface port status data." + ::= { integraEradio 10 } + +integraEradioRangeEntry OBJECT-TYPE + SYNTAX IntegraEradioRangeEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing network physical port status info." + INDEX { integraEradioRangeEntryIndex } + ::= { integraEradioRangesTable 1 } + +IntegraEradioRangeEntry ::= + SEQUENCE { + integraEradioRangeEntryIndex + Integer32, + integraEradioRangeDescr + DisplayString, + integraEradioRangeTxPower + Integer32, + integraEradioRangeTxFrequency + Integer32 + } + +integraEradioRangeEntryIndex OBJECT-TYPE + SYNTAX Integer32 (1..2) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A unique value, greater than zero, for each range + entry. Starts with 1 and is equal to a number of all range + parameters." + ::= { integraEradioRangeEntry 1 } + +integraEradioRangeDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "'Minimal' and 'maximal' labels" + ::= { integraEradioRangeEntry 2 } + +integraEradioRangeTxPower OBJECT-TYPE + SYNTAX Integer32 + UNITS "dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Output power ranges for radio transmitter" + ::= { integraEradioRangeEntry 3 } + +integraEradioRangeTxFrequency OBJECT-TYPE + SYNTAX Integer32 + UNITS "kHz" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Frequency ranges for radio transmitter" + ::= { integraEradioRangeEntry 4 } + +integraEradioPLL OBJECT-TYPE + SYNTAX INTEGER { + error(1), + ok(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "PLL state of local-oscillator generator" + ::= { integraEradio 11 } + +integraEradioRxLevelState OBJECT-TYPE + SYNTAX INTEGER { + ok(1), + low(2), + high(3), + error(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Received signal level state" + ::= { integraEradio 12 } + +integraEradioAtpcState OBJECT-TYPE + SYNTAX INTEGER { + off(1), + on(2), + unknown(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ATPC state" + ::= { integraEradio 13 } + +integraEradioAtpcUpdatePeriod OBJECT-TYPE + SYNTAX Integer32(0..214748364) + UNITS "s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ATPC update period" + ::= { integraEradio 14 } + +integraEradioAtpcRxLevelMin OBJECT-TYPE + SYNTAX Integer32 + UNITS "dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ATPC Minimal level of the received signal" + ::= { integraEradio 15 } + +integraEradioAtpcRxLevelMax OBJECT-TYPE + SYNTAX Integer32 + UNITS "dBm" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ATPC Maximal level of the received signal" + ::= { integraEradio 16 } + + +integraEmodem OBJECT IDENTIFIER ::= { integraE 3 } + +integraEmodemAcquireStatus OBJECT-TYPE + SYNTAX INTEGER { + acquireInProgress(1), + acquireLocked(2), + acquireFailed(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This is the current status of modem data acquire + when queried modem status. + For detailed info use modemAcquireLastStatusDetails." + ::= { integraEmodem 1 } + +integraEmodemNormalizedMse OBJECT-TYPE + SYNTAX FixedDiv10 + UNITS "dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current normalized MSE value" + ::= { integraEmodem 2 } + +-- ldpcDecoderStress OBJECT-TYPE +integraEmodemFECload OBJECT-TYPE + SYNTAX FixedDiv10 + UNITS "dB" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Decoder stress or FEC load value" + ::= { integraEmodem 3 } + +integraEmodemFEClocked OBJECT-TYPE + SYNTAX INTEGER { + no(1), + yes(2), + unknown(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "FEC locked status" + ::= { integraEmodem 4 } + +integraEmodemAcquireLastStatusDetails OBJECT-TYPE + SYNTAX INTEGER { + acquireLocked(1), + acquireSweep(4), + acquireMSEerror(5), + acquireBITerror(6), + acquireStopped(12), + acquireSMerror(13) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This is the last status of successfull or unsuccessful modem data acquire" + ::= { integraEmodem 5 } + +integraEmodemTemperature OBJECT-TYPE + SYNTAX FixedDiv10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modem DSP temperature" + ::= { integraEmodem 6 } + +integraEmodemBandwidth OBJECT-TYPE + SYNTAX Integer32 + UNITS "kHz" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Signal bandwidth" + ::= { integraEmodem 7 } + +integraEmodemModulation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modulation (preferred)" + ::= { integraEmodem 8 } + +integraEmodemRxModulation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current (actual) Rx Modulation" + ::= { integraEmodem 9 } + +integraEmodemTxModulation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current (actual) Tx Modulation" + ::= { integraEmodem 10 } + +integraEmodemRxCapacity OBJECT-TYPE + SYNTAX Integer32 + UNITS "kb/s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Rx ethernet capacity in kilobits per second" + ::= { integraEmodem 11 } + +integraEmodemTxCapacity OBJECT-TYPE + SYNTAX Integer32 + UNITS "kb/s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Tx ethernet capacity in kilobits per second" + ::= { integraEmodem 12 } + +integraEmodemACMBengine OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2), + error(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "ACMB engine status" + ::= { integraEmodem 13 } + +integraEmodemCarrierOffset OBJECT-TYPE + SYNTAX Integer32 + UNITS "Hz" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modem carrier offset" + ::= { integraEmodem 14 } + +integraEmodemCountTime OBJECT-TYPE + SYNTAX Counter64 + UNITS "s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modem performance count time" + ::= { integraEmodem 15 } + +integraEmodemErroredBlock OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modem performance errored blocks" + ::= { integraEmodem 16 } + +integraEmodemErroredSecond OBJECT-TYPE + SYNTAX Counter64 + UNITS "s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modem performance errored seconds" + ::= { integraEmodem 17 } + +integraEmodemSeverelyErroredSecond OBJECT-TYPE + SYNTAX Counter64 + UNITS "s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modem performance severely errored seconds" + ::= { integraEmodem 18 } + +integraEmodemBackgroundBlockError OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modem performance background block errors" + ::= { integraEmodem 19 } + +integraEmodemTotalBlockNumber OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modem performance total block number" + ::= { integraEmodem 20 } + +integraEmodemErroredSecondRatio OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modem performance errored second ratio" + ::= { integraEmodem 21 } + +integraEmodemSeverelyErroredSecondRatio OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modem performance severely errored second ratio" + ::= { integraEmodem 22 } + +integraEmodemBackgroundBlockErrorRatio OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modem performance background block error ratio" + ::= { integraEmodem 23 } + +integraEmodemUptime OBJECT-TYPE + SYNTAX Counter64 + UNITS "s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modem performance : uptime" + ::= { integraEmodem 24 } + +integraEmodemUnavailtime OBJECT-TYPE + SYNTAX Counter64 + UNITS "s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Modem performance : unavailtime" + ::= { integraEmodem 25 } + +integraEmodemModulationACMBmin OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Minimal modulation for ACMB enabled profile" + ::= { integraEmodem 26 } + +integraEmodemModulationACMBmax OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Maximal modulation for ACMB enabled profile" + ::= { integraEmodem 27 } + + +integraEsystem OBJECT IDENTIFIER ::= { integraE 4 } + +integraEsysCPUtemperature OBJECT-TYPE + SYNTAX FixedDiv10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "System CPU temperature" + ::= { integraEsystem 2 } + +integraEsysLicenseExpire OBJECT-TYPE + SYNTAX Gauge32 + UNITS "s" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "License expires after number of seconds. + In the case of -1, check licenseGenStatus status" + ::= { integraEsystem 3 } +integraEsysLicenseGenStatus OBJECT-TYPE + SYNTAX INTEGER { + ok(1), + expired(2), + unknown(3), + unlimitedTime(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "License General status." + ::= { integraEsystem 4 } + +integraEsysPSUvoltage OBJECT-TYPE + SYNTAX Integer32 + UNITS "mV" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Power voltage in mV" + ::= { integraEsystem 5 } + +integraEsysPSUcurrent OBJECT-TYPE + SYNTAX Integer32 + UNITS "mA" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Power current in mA" + ::= { integraEsystem 6 } +integraEsysPSUpower OBJECT-TYPE + SYNTAX Integer32 + UNITS "mW" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Power consumption in mW" + ::= { integraEsystem 7 } +integraEsysBoardTemperature OBJECT-TYPE + SYNTAX FixedDiv10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "System temperature" + ::= { integraEsystem 8 } +integraEsysFreeMemory OBJECT-TYPE + SYNTAX FixedDiv10 + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "System free memory" + ::= { integraEsystem 9 } +integraEsysCPUidle OBJECT-TYPE + SYNTAX FixedDiv10 + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "System CPU idle" + ::= { integraEsystem 10 } + +integraEsysDeviceType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Device type name" + ::= { integraEsystem 11 } + +integraEsysDeviceSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Device serial number" + ::= { integraEsystem 12 } + +integraEsysDeviceProductModel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Device product model code" + ::= { integraEsystem 13 } + +integraEsysFanError OBJECT-TYPE + SYNTAX BITS { + no(0), + fan1(1), + unknown(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Device fan 1 error status" + ::= { integraEsystem 14 } + +-- service sensors +integraEsysXADCtemperature OBJECT-TYPE + SYNTAX FixedDiv10 + UNITS "C" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC Temperature" + ::= { integraEsystem 15 } + +integraEsysVCCint OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Vcc INT" + ::= { integraEsystem 16 } + +integraEsysVCCaux OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Vcc AUX" + ::= { integraEsystem 17 } + +integraEsysVCCbram OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Vcc BRAM" + ::= { integraEsystem 18 } + +integraEsysVCCpint OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Vcc PINT" + ::= { integraEsystem 19 } + +integraEsysVCCpaux OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Vcc PAUX" + ::= { integraEsystem 20 } + +integraEsysVCCoddr OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Vcc ODDR" + ::= { integraEsystem 21 } + +integraEsysXadc6v0AvddMdmAna OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_6V0_AVDD_M - Modem Analog" + ::= { integraEsystem 22 } + +integraEsysXadc1v0AvddSwAna OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_1V0_AVDD_S - Switch Analog" + ::= { integraEsystem 23 } + +integraEsysXadc1v0AvddMdmAna OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_1V0_AVDD_M - Modem Analog" + ::= { integraEsystem 24 } + +integraEsysXadc1v0DvddMdmDig OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_1V0_DVDD_M - Modem Digital" + ::= { integraEsystem 25 } + +integraEsysXadc1v0CoreMdmDig OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_1V0_CORE_M - Modem Digital" + ::= { integraEsystem 26 } + +integraEsysXadc2v5EnvAdcAvddMdmAna OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_2V5_ENVADC_AVDD - Modem Analog" + ::= { integraEsystem 27 } + +integraEsysXadc1v0CoreSwDig OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_1V0_CORE_S - Switch Digital" + ::= { integraEsystem 28 } + +integraEsysXadc5v0IqAvddMdmAna OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_5V0_IQ_AVDD - Modem Analog" + ::= { integraEsystem 29 } + +integraEsysXadc2v5WbDacClAvddMdmAna OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_2V5_WBDAC_CL_AVDD - Modem Analog" + ::= { integraEsystem 30 } + +integraEsysXadc1v2VccPhyDig OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_1V2_VCC - PHY Digital" + ::= { integraEsystem 31 } + +integraEsysXadc4v6AfeDacAvddMdmAna OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_4V6_AFE_DAC_AVDD - Modem Analog" + ::= { integraEsystem 32 } + +integraEsysXadc2v5WbDacAvddMdmAna OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_2V5_WBDAC_AVDD - Modem Analog" + ::= { integraEsystem 33 } + +integraEsysXadc2v5VccSysDig OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_2V5_VCC - System Digital" + ::= { integraEsystem 34 } + +integraEsysXadc3v3VccSysDig OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_3V3_VCC - System Digital" + ::= { integraEsystem 35 } + +integraEsysXadc1v5Ddr3Sw OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_1V5_DDR3_S - Switch DDR3" + ::= { integraEsystem 36 } + +integraEsysXadc2v5WbAdcAvddMdmAna OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_2V5_WBADC_AVDD - Modem Analog" + ::= { integraEsystem 37 } + +integraEsysXadc2v5WbDacPllAvddMdmAna OBJECT-TYPE + SYNTAX FixedDiv20 + UNITS "V" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "XADC_2V5_WBDAC_PLL_AVDD - Modem Analog" + ::= { integraEsystem 38 } + +-- Ethernet +integraEethernet OBJECT IDENTIFIER ::= { integraE 5 } + -- Port status +integraEifStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF IntegraEifPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Network interface port status data." + ::= { integraEethernet 1 } + +integraEifPortEntry OBJECT-TYPE + SYNTAX IntegraEifPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing network physical port status info." + INDEX { integraEifPortStatIndex } + ::= { integraEifStatusTable 1 } + +IntegraEifPortEntry ::= + SEQUENCE { + integraEifPortStatIndex + Integer32, + integraEifPortStatDescr + DisplayString, + integraEifPortType + IANAifType, + integraEifPortMtu + Integer32, + integraEifPortHighSpeed + Gauge32, + integraEifPortPhysAddress + PhysAddress, + integraEifPortAdminStatus + INTEGER, + integraEifPortOperStatus + INTEGER, + integraEifPortLastChange + TimeTicks, + integraEifPortAutoneg + INTEGER, + integraEifPortDuplex + INTEGER, + integraEifPortSyncEthActive + INTEGER, + integraEifPortSyncEthPrio + Integer32, + integraEifPortFlowControl + INTEGER + } + +integraEifPortStatIndex OBJECT-TYPE + SYNTAX Integer32 (1..4) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A unique value, greater than zero, for each physical + network interface. It is recommended that + values are assigned contiguously starting from 1." + ::= { integraEifPortEntry 1 } + +integraEifPortStatDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Physical network interface description. + LAN1 is electrical, LAN2 and LAN3 are SFP + and WAN is radio port." + ::= { integraEifPortEntry 2 } + +integraEifPortType OBJECT-TYPE + SYNTAX IANAifType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of interface, distinguished according to + the physical/link protocol(s) immediately `below' + the network layer in the protocol stack." + ::= { integraEifPortEntry 3 } + +integraEifPortMtu OBJECT-TYPE + SYNTAX Integer32 + UNITS "B" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Maximum transmission unit value in bytes." + ::= { integraEifPortEntry 4 } + +integraEifPortHighSpeed OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Mbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Link speed in 1 000 000 * bits per second." + ::= { integraEifPortEntry 5 } + +integraEifPortPhysAddress OBJECT-TYPE + SYNTAX PhysAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The interface's address at the protocol layer + immediately `below' the network layer in the + protocol stack. For interfaces which do not have + such an address (e.g., a serial line), this object + should contain an octet string of zero length." + ::= { integraEifPortEntry 6 } + +integraEifPortAdminStatus OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2), + unknown(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Desired state of network interfaces. Interfaces + can be enabled(1), disabled(2), unknown(3) (no info received)." + ::= { integraEifPortEntry 7 } + +integraEifPortOperStatus OBJECT-TYPE + SYNTAX INTEGER { + up(1), + down(2), + unknown(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Actual state of interfaces. Link can be up(1), + down(2) or in unknown(3) state." + ::= { integraEifPortEntry 8 } + +integraEifPortLastChange OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This parameter value is always 0 at the moment." + ::= { integraEifPortEntry 9 } + +integraEifPortAutoneg OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2), + unknown(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Auto-negotiation status. Unknown means no info was received." + ::= { integraEifPortEntry 10 } + +integraEifPortDuplex OBJECT-TYPE + SYNTAX INTEGER { + full(1), + half(2), + unknown(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Duplex status for the interface." + ::= { integraEifPortEntry 11 } + +integraEifPortSyncEthActive OBJECT-TYPE + SYNTAX INTEGER { + off(0), + on(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronous Ethernet status. + Can be active(1) or inactive(0)." + ::= { integraEifPortEntry 12 } + +integraEifPortSyncEthPrio OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Synchronous Ethernet priority." + ::= { integraEifPortEntry 13 } + +integraEifPortFlowControl OBJECT-TYPE + SYNTAX INTEGER { + enabled(1), + disabled(2), + unknown(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Flow control status." + ::= { integraEifPortEntry 14 } + + + -- Port statistics +integraEifStatisticsTable OBJECT-TYPE + SYNTAX SEQUENCE OF IntegraEifPortStcEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Network interface port statistics data." + ::= { integraEethernet 2 } + +integraEifPortStcEntry OBJECT-TYPE + SYNTAX IntegraEifPortStcEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing network physical port statistics counter data." + INDEX { integraEifPortStcIndex } + ::= { integraEifStatisticsTable 1 } + +IntegraEifPortStcEntry ::= + SEQUENCE { + integraEifPortStcIndex + Integer32, + integraEifPortStcDescr + DisplayString, + integraEifTimePassed + TimeTicks, + integraEifIngressPackets + Counter64, + integraEifIngressBytes + Counter64, + integraEifEgressPackets + Counter64, + integraEifEgressBytes + Counter64, + integraEifEtherStatsMulticastPkts + Counter64, + integraEifEtherStatsBroadcastPkts + Counter64, + integraEifEtherStatsPkts64Octets + Counter64, + integraEifEtherStatsPkts65to127Octets + Counter64, + integraEifEtherStatsPkts128to255Octets + Counter64, + integraEifEtherStatsPkts256to511Octets + Counter64, + integraEifEtherStatsPkts512to1023Octets + Counter64, + integraEifEtherStatsPkts1024to1518Octets + Counter64, + integraEifEtherStatsOversizePkts + Counter64, + integraEifEtherRxOversizePkts + Counter64, + integraEifEtherTxOversizePkts + Counter64, + integraEifEtherStatsOctets + Counter64, + integraEifEtherStatsPkts + Counter64, + integraEifEtherStatsTXNoErrors + Counter64, + integraEifEtherStatsRXNoErrors + Counter64, + integraEifEtherStatsPkts1519to1522Octets + Counter64, + integraEifIfInOctets + Counter64, + integraEifIfOutOctets + Counter64, + integraEifDot1dTpPortInFrames + Counter64, + integraEifDot1dTpPortOutFrames + Counter64, + integraEifReceivedPkts64Octets + Counter64, + integraEifTransmittedPkts64Octets + Counter64, + integraEifReceivedPkts65to127Octets + Counter64, + integraEifTransmittedPkts65to127Octets + Counter64, + integraEifReceivedPkts128to255Octets + Counter64, + integraEifTransmittedPkts128to255Octets + Counter64, + integraEifReceivedPkts256to511Octets + Counter64, + integraEifTransmittedPkts256to511Octets + Counter64, + integraEifReceivedPkts512to1023Octets + Counter64, + integraEifTransmittedPkts512to1023Octets + Counter64, + integraEifReceivedPkts1024to1518Octets + Counter64, + integraEifTransmittedPkts1024to1518Octets + Counter64, + integraEifIfInBroadcastPkts + Counter64, + integraEifIfOutBroadcastPkts + Counter64, + integraEifIfInMulticastPkts + Counter64, + integraEifIfOutMulticastPkts + Counter64, + integraEifDot3InPauseFrames + Counter64, + integraEifDot3OutPauseFrames + Counter64, + integraEifEtherStatsUndersizePkts + Counter64, + integraEifEtherStatsFragments + Counter64, + integraEifEtherStatsCRCAlignErrors + Counter64, + integraEifEtherStatsJabbers + Counter64, + integraEifIngressBPS + Integer32, + integraEifIngressPPS + Integer32, + integraEifEgressBPS + Integer32, + integraEifEgressPPS + Integer32, + integraEifAllCoSQoutPackets + Counter64, + integraEifAllCoSQoutBytes + Counter64, + integraEifAllCoSQdroppedPackets + Counter64, + integraEifAllCoSQdroppedBytes + Counter64, + integraEifProcessedRxPackets + Counter64, + integraEifProcessedRxBytes + Counter64 + } + +integraEifPortStcIndex OBJECT-TYPE + SYNTAX Integer32 (1..5) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A unique value, greater than zero, for each physical + network interface. It is recommended that + values are assigned contiguously starting from 1." + ::= { integraEifPortStcEntry 1 } + +integraEifPortStcDescr OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Physical network interface description. + LAN1 is electrical, LAN2 and LAN3 are SFP, + WAN is radio port and MNG is internal management interface." + ::= { integraEifPortStcEntry 2 } + +integraEifTimePassed OBJECT-TYPE + SYNTAX TimeTicks + UNITS "s/100" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Statistics collection time." + ::= { integraEifPortStcEntry 3 } + +integraEifIngressPackets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Packets that ingress on the port." + ::= { integraEifPortStcEntry 4 } + +integraEifIngressBytes OBJECT-TYPE + SYNTAX Counter64 + UNITS "B" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bytes that ingress on the port." + ::= { integraEifPortStcEntry 5 } + +integraEifEgressPackets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Packets that egress on the port." + ::= { integraEifPortStcEntry 6 } + +integraEifEgressBytes OBJECT-TYPE + SYNTAX Counter64 + UNITS "B" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bytes that egress on the port." + ::= { integraEifPortStcEntry 7 } + +integraEifEtherStatsMulticastPkts OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of good packets (both received and + transmitted) that were directed to a multicast address. + Note that this number does not include packets directed + to the broadcast address." + ::= { integraEifPortStcEntry 8 } + +integraEifEtherStatsBroadcastPkts OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of good packets (both received and + transmitted) that were directed to the broadcast address. + Note that this does not include multicast packets." + ::= { integraEifPortStcEntry 9 } + +integraEifEtherStatsPkts64Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of packets (including bad + packets) (both received and transmitted) + that were 64 octets in length + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 10 } + +integraEifEtherStatsPkts65to127Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of packets (including bad + packets) (both received and transmitted) + that were between 65 and 127 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 11 } + +integraEifEtherStatsPkts128to255Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of packets (including bad + packets) (both received and transmitted) that were + between 128 and 255 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 12 } + +integraEifEtherStatsPkts256to511Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of packets (including bad + packets) (both received and transmitted) that were + between 256 and 511 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 13 } + +integraEifEtherStatsPkts512to1023Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of packets (including bad + packets) (both received and transmitted) that were + between 512 and 1023 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 14 } + +integraEifEtherStatsPkts1024to1518Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of packets (including bad + packets) (both received and transmitted) that were + between 1024 and 1518 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 15 } + +integraEifEtherStatsOversizePkts OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of packets (both received and + transmitted) that were longer than 1518 + octets (excluding framing bits but including + FCS octets) but were otherwise well formed." + ::= { integraEifPortStcEntry 16 } + +integraEifEtherRxOversizePkts OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of packets received + that were longer than 1518 octets + (excluding framing bits but including + FCS octets) but were otherwise well formed." + ::= { integraEifPortStcEntry 17 } + +integraEifEtherTxOversizePkts OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of packets transmitted + that were longer than 1518 octets + (excluding framing bits but including + FCS octets) but were otherwise well formed." + ::= { integraEifPortStcEntry 18 } + +integraEifEtherStatsOctets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of octets of data (including + those in bad packets) both received and + transmitted." + ::= { integraEifPortStcEntry 19 } + +integraEifEtherStatsPkts OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of packets (including bad packets) + both received and transmitted." + ::= { integraEifPortStcEntry 20 } + +integraEifEtherStatsTXNoErrors OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of packets that were transmitted + without errors." + ::= { integraEifPortStcEntry 21 } + +integraEifEtherStatsRXNoErrors OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of packets that were received + without errors." + ::= { integraEifPortStcEntry 22 } + +integraEifEtherStatsPkts1519to1522Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of packets (including bad + packets) (both received and transmitted) that were + between 1519 and 1522 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 23 } + +integraEifIfInOctets OBJECT-TYPE + SYNTAX Counter64 + UNITS "octet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of octets of data (including + those in bad packets) that were received." + ::= { integraEifPortStcEntry 24 } + +integraEifIfOutOctets OBJECT-TYPE + SYNTAX Counter64 + UNITS "octet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of octets of data (including + those in bad packets) that were transmitted." + ::= { integraEifPortStcEntry 25 } + +integraEifDot1dTpPortInFrames OBJECT-TYPE + SYNTAX Counter64 + UNITS "frame" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of frames that have been received by + this port from its segment." + ::= { integraEifPortStcEntry 26 } + +integraEifDot1dTpPortOutFrames OBJECT-TYPE + SYNTAX Counter64 + UNITS "frame" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of frames that have been transmitted by + this port to its segment." + ::= { integraEifPortStcEntry 27 } + +integraEifReceivedPkts64Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of received packets that were + 64 octets in length (excluding framing bits + but including FCS octets)." + ::= { integraEifPortStcEntry 28 } + +integraEifTransmittedPkts64Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of transmitted packets that were + 64 octets in length (excluding framing bits + but including FCS octets)." + ::= { integraEifPortStcEntry 29 } + +integraEifReceivedPkts65to127Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of received packets that were + between 65 and 127 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 30 } + +integraEifTransmittedPkts65to127Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of transmitted packets that were + between 65 and 127 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 31 } + +integraEifReceivedPkts128to255Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of received packets that were + between 128 and 255 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 32 } + +integraEifTransmittedPkts128to255Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of transmitted packets that were + between 128 and 255 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 33 } + +integraEifReceivedPkts256to511Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of received packets that were + between 256 and 511 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 34 } + +integraEifTransmittedPkts256to511Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of transmitted packets that were + between 256 and 511 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 35 } + +integraEifReceivedPkts512to1023Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of received packets that were + between 512 and 1023 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 36 } + +integraEifTransmittedPkts512to1023Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of transmitted packets that were + between 512 and 1023 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 37 } + +integraEifReceivedPkts1024to1518Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of received packets that were + between 1024 and 1518 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 38 } + +integraEifTransmittedPkts1024to1518Octets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Total number of transmitted packets that were + between 1024 and 1518 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { integraEifPortStcEntry 39 } + +integraEifIfInBroadcastPkts OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of received good packets + that were directed to the broadcast address. + Note that this does not include multicast packets." + ::= { integraEifPortStcEntry 40 } + +integraEifIfOutBroadcastPkts OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of transmitted good packets + that were directed to the broadcast address. + Note that this does not include multicast packets." + ::= { integraEifPortStcEntry 41 } + +integraEifIfInMulticastPkts OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of received good packets + that were directed to a multicast address. + Note that this number does not include broadcast packets." + ::= { integraEifPortStcEntry 42 } + +integraEifIfOutMulticastPkts OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of transmitted good packets + that were directed to a multicast address. + Note that this number does not include broadcast packets." + ::= { integraEifPortStcEntry 43 } + +integraEifDot3InPauseFrames OBJECT-TYPE + SYNTAX Counter64 + UNITS "frame" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A count of MAC Control frames received on this + interface with an opcode indicating the PAUSE + operation. + This counter does not increment when the + interface is operating in half-duplex mode." + ::= { integraEifPortStcEntry 44 } + +integraEifDot3OutPauseFrames OBJECT-TYPE + SYNTAX Counter64 + UNITS "frame" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A count of MAC Control frames transmitted on + this interface with an opcode indicating the + PAUSE operation. + This counter does not increment when the + interface is operating in half-duplex mode." + ::= { integraEifPortStcEntry 45 } + +integraEifEtherStatsUndersizePkts OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of packets received that were + less than 64 octets long (excluding framing bits, + but including FCS octets) and were otherwise well + formed." + ::= { integraEifPortStcEntry 46 } + +integraEifEtherStatsFragments OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of packets received that were less than + 64 octets in length (excluding framing bits but including + FCS octets) and had either a bad Frame Check Sequence + (FCS) with an integral number of octets (FCS Error) or a + bad FCS with a non-integral number of octets (Alignment + Error). + Note that it is entirely normal for etherStatsFragments to + increment. This is because it counts both runts (which are + normal occurrences due to collisions) and noise hits." + ::= { integraEifPortStcEntry 47 } + +integraEifEtherStatsCRCAlignErrors OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of packets received that + had a length (excluding framing bits, but + including FCS octets) of between 64 and 1518 + octets, inclusive, but had either a bad + Frame Check Sequence (FCS) with an integral + number of octets (FCS Error) or a bad FCS with + a non-integral number of octets (Alignment Error)." + ::= { integraEifPortStcEntry 48 } + +integraEifEtherStatsJabbers OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of packets received that were + longer than 1518 octets (excluding framing bits, + but including FCS octets), and had either a bad + Frame Check Sequence (FCS) with an integral number + of octets (FCS Error) or a bad FCS with a non-integral + number of octets (Alignment Error). + Note that this definition of jabber is different + than the definition in IEEE-802.3 section 8.2.1.5 + (10BASE5) and section 10.3.1.4 (10BASE2). These + documents define jabber as the condition where any + packet exceeds 20 ms. The allowed range to detect + jabber is between 20 ms and 150 ms." + ::= { integraEifPortStcEntry 49 } + +integraEifIngressBPS OBJECT-TYPE + SYNTAX Integer32 + UNITS "Bps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ingoing data transfer rate in bytes per second." + ::= { integraEifPortStcEntry 50 } + +integraEifIngressPPS OBJECT-TYPE + SYNTAX Integer32 + UNITS "pps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Ingoing data transfer rate in packets per second." + ::= { integraEifPortStcEntry 51 } + +integraEifEgressBPS OBJECT-TYPE + SYNTAX Integer32 + UNITS "Bps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Outgoing data transfer rate in bytes per second." + ::= { integraEifPortStcEntry 52 } + +integraEifEgressPPS OBJECT-TYPE + SYNTAX Integer32 + UNITS "pps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Outgoing data transfer rate in packets per second." + ::= { integraEifPortStcEntry 53 } + +integraEifAllCoSQoutPackets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "All CoSQ outgoing packets." + ::= { integraEifPortStcEntry 54 } + +integraEifAllCoSQoutBytes OBJECT-TYPE + SYNTAX Counter64 + UNITS "B" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "All CoSQ outgoing bytes." + ::= { integraEifPortStcEntry 55 } + +integraEifAllCoSQdroppedPackets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "All CoSQ dropped packets." + ::= { integraEifPortStcEntry 56 } + +integraEifAllCoSQdroppedBytes OBJECT-TYPE + SYNTAX Counter64 + UNITS "B" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "All CoSQ dropped bytes." + ::= { integraEifPortStcEntry 57 } + +integraEifProcessedRxPackets OBJECT-TYPE + SYNTAX Counter64 + UNITS "packet" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Processed received packets." + ::= { integraEifPortStcEntry 58 } + +integraEifProcessedRxBytes OBJECT-TYPE + SYNTAX Counter64 + UNITS "B" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Processed received bytes." + ::= { integraEifPortStcEntry 59 } + + +integraEifLspPortAdminState OBJECT-TYPE + SYNTAX INTEGER { + disabled(1), + lsp(2), + backup(3), + unknown(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "LSP port status." + ::= { integraEethernet 3 } + +integraEifLspPortList OBJECT-TYPE + SYNTAX BITS { + none(0), + lan1(1), + lan2(2), + lan3(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "LSP port status." + ::= { integraEethernet 4 } + +integraEifLspPortStatus OBJECT-TYPE + SYNTAX INTEGER { + lspPortOK(1), + lspPortDownBlockedByLSP(2), + backupNoLink(3), + backupLinkActive(4), + backupLinkReady(5), + unknown(6) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "LSP port status." + ::= { integraEethernet 5 } + +-- Configuration applying/saving objects + +integraEexecuteConfig OBJECT-TYPE + SYNTAX INTEGER { + execute(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "This object can only be set to 1. + It initiates new running configuration + applying using values, that have been set before. + Setting it when no new changes are available + will do nothing and return an error. + GET will return 0 if there were no errors, + while executing configuration or will return + a bitmask, that shows which SET requests have failed. + Those failed requests will be shown bit wise + from LSB as follows: + BIT0 radioTxMuteDuration + BIT1 radioTxFrequency + BIT2 radioTxPower" + ::= { integraE 6 } + +integraEneedStore OBJECT-TYPE + SYNTAX INTEGER { + no(0) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "This object shows if there is unsaved, + but executed (running) configuration. + Unsaved changes will be lost after + device reboot. Unsaved entities are shown + bit wise, starting from LSB as follows: + BIT0 Aggregation + BIT1 Event log + BIT2 Modem + BIT3 Network + BIT4 Performance + BIT5 Radio + BIT6 SNMP + BIT7 Synchronous Ethernet + BIT8 System" + ::= { integraE 7 } + +integraEstoreConfig OBJECT-TYPE + SYNTAX INTEGER { + store(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION "This object can only be set to 1. + It initiates saving of running configuration. + It will only work if there are unsaved, + but executed (running) changes (configuration). + Setting it when no new running configuration + is available will do nothing and return an error." + ::= { integraE 8 } + + +-- IP settings + +integraEnetCfg OBJECT IDENTIFIER ::= { integraE 9 } + +integraEnetCfgIPaddress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Local IP address" + ::= { integraEnetCfg 1 } + +integraEnetCfgIPmask OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Local IP mask" + ::= { integraEnetCfg 2 } + +integraEnetCfgIPgateway OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION "IP gateway + Send '0' or '255.255.255.255' to clear." + ::= { integraEnetCfg 3 } + +integraEnetCfgRemoteIPaddress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Remote IP address" + ::= { integraEnetCfg 4 } + + +-- Conformance + +integraEConformance OBJECT IDENTIFIER ::= { integraE 10 } +integraECompliances OBJECT IDENTIFIER ::= { integraEConformance 1 } + +integraECompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION "The compliance statement for SNMP engine which + implements the SAF Tehnika Integra-E device." + MODULE -- this module + MANDATORY-GROUPS { + integraEMiscGroup, + integraERadioGroup, + integraEModemGroup, + integraESystemGroup, + integraEEthernetGeneralGroup, + integraEEthernetMiiPortGroup } + ::= { integraECompliances 1 } +integraEGroups OBJECT IDENTIFIER ::= { integraEConformance 2 } + +integraEMiscGroup OBJECT-GROUP + OBJECTS { + integraEtimestamp + } + STATUS current + DESCRIPTION "misc data" + ::= { integraEGroups 1 } + +integraERadioGroup OBJECT-GROUP + OBJECTS { + integraEradioTxPower, + integraEradioTxFrequency, + integraEradioRxLevel, + integraEradioSide, + integraEradioTxMute, + integraEradioDuplexShift, + integraEradioRxFrequency, + integraEradioTemperature, + integraEradioTxMuteDuration, + integraEradioRangeEntryIndex, + integraEradioRangeDescr, + integraEradioRangeTxPower, + integraEradioRangeTxFrequency, + integraEradioPLL, + integraEradioRxLevelState, + integraEradioAtpcState, + integraEradioAtpcUpdatePeriod, + integraEradioAtpcRxLevelMin, + integraEradioAtpcRxLevelMax + } + STATUS current + DESCRIPTION "Radio group." + ::= { integraEGroups 2 } + +integraEModemGroup OBJECT-GROUP + OBJECTS { + integraEmodemAcquireStatus, + integraEmodemNormalizedMse, + integraEmodemFECload, + integraEmodemFEClocked, + integraEmodemAcquireLastStatusDetails, + integraEmodemTemperature, + integraEmodemBandwidth, + integraEmodemModulation, + integraEmodemRxModulation, + integraEmodemTxModulation, + integraEmodemRxCapacity, + integraEmodemTxCapacity, + integraEmodemACMBengine, + integraEmodemCarrierOffset, + integraEmodemCountTime, + integraEmodemErroredBlock, + integraEmodemErroredSecond, + integraEmodemSeverelyErroredSecond, + integraEmodemBackgroundBlockError, + integraEmodemTotalBlockNumber, + integraEmodemErroredSecondRatio, + integraEmodemSeverelyErroredSecondRatio, + integraEmodemBackgroundBlockErrorRatio, + integraEmodemUptime, + integraEmodemUnavailtime, + integraEmodemModulationACMBmin, + integraEmodemModulationACMBmax + } + STATUS current + DESCRIPTION "Modem group." + ::= { integraEGroups 3 } + +integraESystemGroup OBJECT-GROUP + OBJECTS { + integraEsysCPUtemperature, + integraEsysLicenseExpire, + integraEsysLicenseGenStatus, + integraEsysPSUvoltage, + integraEsysPSUcurrent, + integraEsysPSUpower, + integraEsysBoardTemperature, + integraEsysFreeMemory, + integraEsysCPUidle, + integraEsysDeviceType, + integraEsysDeviceSerial, + integraEsysDeviceProductModel, + integraEsysFanError, + integraEexecuteConfig, + integraEneedStore, + integraEstoreConfig, + integraEsysXADCtemperature, + integraEsysVCCint, + integraEsysVCCaux, + integraEsysVCCbram, + integraEsysVCCpint, + integraEsysVCCpaux, + integraEsysVCCoddr, + integraEsysXadc6v0AvddMdmAna, + integraEsysXadc1v0AvddSwAna, + integraEsysXadc1v0AvddMdmAna, + integraEsysXadc1v0DvddMdmDig, + integraEsysXadc1v0CoreMdmDig, + integraEsysXadc2v5EnvAdcAvddMdmAna, + integraEsysXadc1v0CoreSwDig, + integraEsysXadc5v0IqAvddMdmAna, + integraEsysXadc2v5WbDacClAvddMdmAna, + integraEsysXadc1v2VccPhyDig, + integraEsysXadc4v6AfeDacAvddMdmAna, + integraEsysXadc2v5WbDacAvddMdmAna, + integraEsysXadc2v5VccSysDig, + integraEsysXadc3v3VccSysDig, + integraEsysXadc1v5Ddr3Sw, + integraEsysXadc2v5WbAdcAvddMdmAna, + integraEsysXadc2v5WbDacPllAvddMdmAna + } + STATUS current + DESCRIPTION "System group." + ::= { integraEGroups 4 } + +integraEEthernetGeneralGroup OBJECT-GROUP + OBJECTS { + integraEifPortStatIndex, + integraEifPortStatDescr, + integraEifPortType, + integraEifPortMtu, + integraEifPortHighSpeed, + integraEifPortPhysAddress, + integraEifPortAdminStatus, + integraEifPortOperStatus, + integraEifPortLastChange, + integraEifPortAutoneg, + integraEifPortDuplex, + integraEifPortSyncEthActive, + integraEifPortSyncEthPrio, + integraEifPortFlowControl, + integraEifPortStcIndex, + integraEifPortStcDescr, + integraEifTimePassed, + integraEifIngressPackets, + integraEifIngressBytes, + integraEifEgressPackets, + integraEifEgressBytes, + integraEifEtherRxOversizePkts, + integraEifEtherTxOversizePkts, + integraEifReceivedPkts64Octets, + integraEifTransmittedPkts64Octets, + integraEifReceivedPkts65to127Octets, + integraEifTransmittedPkts65to127Octets, + integraEifReceivedPkts128to255Octets, + integraEifTransmittedPkts128to255Octets, + integraEifReceivedPkts256to511Octets, + integraEifTransmittedPkts256to511Octets, + integraEifReceivedPkts512to1023Octets, + integraEifTransmittedPkts512to1023Octets, + integraEifReceivedPkts1024to1518Octets, + integraEifTransmittedPkts1024to1518Octets, + integraEifIfInBroadcastPkts, + integraEifIfOutBroadcastPkts, + integraEifIfInMulticastPkts, + integraEifIfOutMulticastPkts, + integraEifIngressBPS, + integraEifIngressPPS, + integraEifEgressBPS, + integraEifEgressPPS, + integraEifAllCoSQoutPackets, + integraEifAllCoSQoutBytes, + integraEifAllCoSQdroppedPackets, + integraEifAllCoSQdroppedBytes, + integraEifProcessedRxPackets, + integraEifProcessedRxBytes, + integraEnetCfgIPaddress, + integraEnetCfgIPmask, + integraEnetCfgIPgateway, + integraEnetCfgRemoteIPaddress, + integraEifLspPortAdminState, + integraEifLspPortList, + integraEifLspPortStatus + } + STATUS current + DESCRIPTION "A collection to objects, providing info applicable to + all network interfaces." + ::= { integraEGroups 5 } + +integraEEthernetMiiPortGroup OBJECT-GROUP + OBJECTS { + integraEifEtherStatsMulticastPkts, + integraEifEtherStatsBroadcastPkts, + integraEifEtherStatsPkts64Octets, + integraEifEtherStatsPkts65to127Octets, + integraEifEtherStatsPkts128to255Octets, + integraEifEtherStatsPkts256to511Octets, + integraEifEtherStatsPkts512to1023Octets, + integraEifEtherStatsPkts1024to1518Octets, + integraEifEtherStatsOversizePkts, + integraEifEtherStatsOctets, + integraEifEtherStatsPkts, + integraEifEtherStatsTXNoErrors, + integraEifEtherStatsRXNoErrors, + integraEifEtherStatsPkts1519to1522Octets, + integraEifIfInOctets, + integraEifIfOutOctets, + integraEifDot1dTpPortInFrames, + integraEifDot1dTpPortOutFrames, + integraEifDot3InPauseFrames, + integraEifDot3OutPauseFrames, + integraEifEtherStatsUndersizePkts, + integraEifEtherStatsFragments, + integraEifEtherStatsCRCAlignErrors, + integraEifEtherStatsJabbers + } + STATUS current + DESCRIPTION "A collection of objects, providing info applicable + only to MII group interfaces." + ::= { integraEGroups 6 } + + +END |