+--* SAGEM SA *
+--*******************************************************************
+--*******************************************************************
+
+-- Filename: GigE
+-- File type: .mib
+--
+-- Description: SNMPc source Mib file.
+-- The MIB module defines the gigabitEthernet card managment in Adr2500c
+--
+-- Version: 19 11 2002
+--
+-- Date(DD MM YYYY): 15 11 02 last update for IONOS NMS
+--
+-- Contact: D. Mobuchon, F. Bonnevialle
+--
+-- History:
+-- Name: S.LAURENT
+-- Date: 22 05 2002
+-- Desc: original
+--
+-- Name: F.Bonnevialle
+-- Date: 15 11 2002
+-- Desc: Modification for SilverCreek Compiler
+--
+--*******************************************************************
+--*******************************************************************
+--* Copyright (c) 2002, SAGEM , All rights reserved. *
+--*******************************************************************
+
+
+
+
+--*******************************************************************
+-- MIB: GIGE-MIB
+--*******************************************************************
+GIGE-MIB DEFINITIONS ::= BEGIN
+
+--*******************************************************************
+-- IMPORTS
+--*******************************************************************
+ IMPORTS
+ adr2500c FROM ADR2500C-MIB
+ SagemBoolean, Severity FROM EQUIPMENT-MIB
+ MODULE-IDENTITY,OBJECT-TYPE,Counter64 FROM SNMPv2-SMI
+ DisplayString, PhysAddress FROM SNMPv2-TC;
+
+ gige MODULE-IDENTITY
+ LAST-UPDATED "0205220000Z"
+ ORGANIZATION "SAGEM-Tolbiac drd/ddp/tmhd"
+ CONTACT-INFO
+ " "
+ DESCRIPTION
+ "The MIB module specific for GigE module of Adr2500c"
+ ::= { adr2500c 10 }
+
+
+--*******************************************************************
+--* Gige part
+--*******************************************************************
+
+ BandwidthSize ::= INTEGER
+ {
+ none(0),
+ stm1(1),
+ stm4(4),
+ stm16(16),
+ stm64(64)
+ }
+
+ gigeNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of gigabitEthernet cards in equipment."
+ ::= { gige 10 }
+
+ gigeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF GigeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of gigabitEthernet cards in equipment."
+ ::= { gige 11 }
+
+ gigeEntry OBJECT-TYPE
+ SYNTAX GigeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular gigabitEthernet card of the equipment."
+ INDEX { gigeIndex }
+ ::= { gigeTable 1 }
+
+ GigeEntry ::= SEQUENCE {
+ gigeIndex INTEGER, -- boardIndex
+ gigeSdhBandwidth BandwidthSize,
+ gigeAutoTest SagemBoolean,
+ gigeWarmStart SagemBoolean
+ }
+
+ gigeIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular gigabitEthernet card of the equipment.
+ The value of this index is a constant value assigned to an entry at
+ equipment design time. It is usualy related to harware"
+ ::= { gigeEntry 1 }
+
+ gigeSdhBandwidth OBJECT-TYPE
+ SYNTAX BandwidthSize
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field set the size of the SDH Bandwidth which is allocated to the gigabitEthernet card."
+ ::= { gigeEntry 2 }
+
+ gigeAutoTest OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to true, an autotest is executed on the gigabitEthernet card."
+ ::= { gigeEntry 3 }
+
+ gigeWarmStart OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to true, a warmStart is launched on the gigabitEthernet card."
+ ::= { gigeEntry 4 }
+
+ -- End of gige description
+
+
+--*******************************************************************
+--* Maintenance part
+--*******************************************************************
+
+ LoopbackGE ::= INTEGER
+ {
+ none(0), -- GE-SDH Bidirectionnal Transmission
+ local1(1), -- GE-GE Loopback (above GFP)
+ local2(2), -- GE-GE Loopback (beyong GFP)
+ local3(3), -- GE-GE Loopback (into SERDES)
+ local4(4), -- GE-GE Loopback (into GMAC Bloc)
+ remote(10) -- SDH-SDH Loopback (into Tramer)
+ }
+
+
+ maintenanceNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of gigabitEthernet ports in equipment."
+ ::= { gige 20 }
+
+ maintenanceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MaintenanceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of gigabitEthernet ports in equipment."
+ ::= { gige 21 }
+
+ maintenanceEntry OBJECT-TYPE
+ SYNTAX MaintenanceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular gigabitEthernet port of the equipment."
+ INDEX { maintenanceIndex }
+ ::= { maintenanceTable 1 }
+
+ MaintenanceEntry ::= SEQUENCE {
+ maintenanceIndex INTEGER, -- channelIndex = nspiTTPIndex
+ maintenanceAutoTest SagemBoolean,
+ maintenanceLoopback LoopbackGE,
+ maintenancePRBSSent DisplayString,
+ maintenancePRBSReceived DisplayString,
+ maintenanceResetAllCounters SagemBoolean,
+ maintenanceResetLanCounters SagemBoolean,
+ maintenanceResetGfpCounters SagemBoolean,
+ maintenanceResetQosCounters SagemBoolean
+ }
+
+ maintenanceIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular gigabitEthernet port of the equipment.
+ The value of this index is a constant value assigned to an entry at
+ equipment design time. It is usualy related to harware"
+ ::= { maintenanceEntry 1 }
+
+ maintenanceAutoTest OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to true, an autotest is executed on the gigabitEthernet port."
+ ::= { maintenanceEntry 2 }
+
+ maintenanceLoopback OBJECT-TYPE
+ SYNTAX LoopbackGE
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field set a loopback mode to a particular gigabitEthernet port."
+ ::= { maintenanceEntry 3 }
+
+ maintenancePRBSSent OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field allows to sent a PRBS frame on a particular gigabitEthernet port."
+ ::= { maintenanceEntry 4 }
+
+ maintenancePRBSReceived OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value is the actual PRBS frame received in the particular gigabitEthernet port."
+ ::= { maintenanceEntry 5 }
+
+ maintenanceResetAllCounters OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to true, all counters attached to this interface are deleted."
+ ::= { maintenanceEntry 6 }
+
+ maintenanceResetLanCounters OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to true, all QoS counters attached to this interface are deleted."
+ ::= { maintenanceEntry 7 }
+
+ maintenanceResetGfpCounters OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to true, all Gfp counters attached to this interface are deleted."
+ ::= { maintenanceEntry 8 }
+
+ maintenanceResetQosCounters OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to true, all Qos counters attached to this interface are deleted."
+ ::= { maintenanceEntry 9 }
+
+ -- End of maintenance part
+
+
+--*******************************************************************
+--* QoS part
+--*******************************************************************
+
+ QosType ::= INTEGER
+ {
+ none(0),
+ pauseMode(1),
+ userPriority(2),
+ vlanId(3),
+ balanced(4),
+ ipv4TOS(10),
+ ipv6TClass(11),
+ dscp(13)
+ }
+
+ CongestionControl ::= INTEGER
+ {
+ none(0),
+ red(1), -- Random Early Detection
+ wred(2) -- Weighted Random Early Detection
+ }
+
+ SchedulingSystem ::= INTEGER
+ {
+ unknown(0),
+ spq(1), -- Strict Priority Queuing
+ wfq(4), -- Weighted Fair Queuing
+ cbwfq(5), -- Class-Based Weighted Fair Queuing
+ wrr(10) -- Weighted Round Robbin
+ }
+
+
+ qosNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of Quality of Service set in equipment. This number match to channelNumber because
+ there is only one Qos per Sdh Channel.
+ = number of entries in qosTable"
+ ::= { gige 30 }
+
+ qosTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF QosEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of Qos in equipment."
+ ::= { gige 31 }
+
+ qosEntry OBJECT-TYPE
+ SYNTAX QosEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular qos of the equipment."
+ INDEX { qosIndex }
+ ::= { qosTable 1 }
+
+ QosEntry ::= SEQUENCE {
+ qosIndex INTEGER, -- channelIndex = nspiTTPIndex
+ qosClassNumber INTEGER,
+ qosType QosType,
+ qosCongestionControl CongestionControl,
+ qosSchedulingSystem SchedulingSystem,
+ qosBwREnable SagemBoolean,
+ qosHCInCCDiscardsGe Counter64,
+ qosHCInCCDiscardsWan Counter64
+ }
+
+ qosIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular QoS of the equipment.
+ The value of this index is a constant value assigned to an entry at
+ equipment design time. It is usualy related to harware"
+ ::= { qosEntry 1 }
+
+ qosClassNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field allows to choose the number of CoS defined for the QoS"
+ ::= { qosEntry 2 }
+
+ qosType OBJECT-TYPE
+ SYNTAX QosType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field allows to choose the type of Qos"
+ ::= { qosEntry 3 }
+
+ qosCongestionControl OBJECT-TYPE
+ SYNTAX CongestionControl
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field allows to choose a mechanism to manage congestion problems. Some Type of Qos
+ force the value of this field. "
+ ::= { qosEntry 4 }
+
+ qosSchedulingSystem OBJECT-TYPE
+ SYNTAX SchedulingSystem
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field allows to choose a mechanism to manage congestion problems. "
+ ::= { qosEntry 5 }
+
+ qosBwREnable OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field allows to activate or desactivate the Sdh throughput reservation feature. "
+ ::= { qosEntry 6 }
+
+ qosHCInCCDiscardsGe OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets received on the GE interface which were discarded to prevent from switch saturation"
+ ::= { qosEntry 7 }
+
+ qosHCInCCDiscardsWan OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets received on the WAN interface which were discarded to prevent from switch saturation"
+ ::= { qosEntry 8 }
+
+ -- End of QoS part
+
+
+
+
+--*******************************************************************
+--* CoS part
+--*******************************************************************
+
+ CosId ::= INTEGER
+ {
+ cos0(0),
+ cos1(1),
+ cos2(2),
+ cos3(3),
+ cos4(4),
+ cos5(5),
+ cos6(6),
+ cos7(7)
+ }
+
+ cosNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of Class of Service set in equipment
+ = number of entries in cosTable
+ = qosNumber * qosClassNumber"
+ ::= { gige 40 }
+
+ cosTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CosEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of CoS in equipment."
+ ::= { gige 41 }
+
+ cosEntry OBJECT-TYPE
+ SYNTAX CosEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular CoS of the equipment."
+ INDEX { cosIndex }
+ ::= { cosTable 1 }
+
+ CosEntry ::= SEQUENCE {
+ cosIndex INTEGER,
+ cosQosId INTEGER, -- qosIndex
+ cosId CosId,
+ cosDefinition DisplayString,
+ cosBwRRatioMin INTEGER,
+ cosBwRRatioMax INTEGER,
+ cosHCInOctets Counter64,
+ cosHCOutOctets Counter64,
+ cosHCInPkts Counter64,
+ cosHCOutPkts Counter64,
+ cosHCInCCDiscards Counter64
+ }
+
+ cosIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular CoS of the equipment.
+ The value of this index is a constant value assigned to an entry at
+ equipment design time. It is usualy related to harware. Its values are taken between 1 and cosNumber."
+ ::= { cosEntry 1 }
+
+ cosQosId OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This field allows to identify which QoS this Class is belonging. Its values must match to qosIndex."
+ ::= { cosEntry 2 }
+
+ cosId OBJECT-TYPE
+ SYNTAX CosId
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " This field identify the class of Service."
+ ::= { cosEntry 3 }
+
+ cosDefinition OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This optional textual field brings some precisions about the CoS configuration. "
+ ::= { cosEntry 4 }
+
+ cosBwRRatioMin OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the qosBwREnable field is set to True, then this field allows to configure the guaranted percentage of SDH
+ throughput which must be booked up for the CoS"
+ ::= { cosEntry 5 }
+
+ cosBwRRatioMax OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the qosBwREnable field is set to True, then this field allows to configure the maximum percentage of SDH
+ throughput which can be booked up for the CoS"
+ ::= { cosEntry 6 }
+
+ cosHCInOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets received on the GE interface (excluding framing characters preambule and sfd)
+ and belonging to a CosId packet"
+ ::= { cosEntry 7 }
+
+ cosHCOutOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets transmitted out of the Wan interface (excluding framing characters preambule and sfd)
+ and belonging to a CosId paket"
+ ::= { cosEntry 8 }
+
+ cosHCInPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets received on the GE interface (excluding framing characters preambule and sfd)
+ and belonging to a CosId packet"
+ ::= { cosEntry 9 }
+
+ cosHCOutPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets transmitted out of the Wan interface (excluding framing characters preambule and sfd)
+ and belonging to a CosId paket"
+ ::= { cosEntry 10 }
+
+ cosHCInCCDiscards OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of CosId packets received on the GE interface which were discarded by RED/WRED/BandWidthReservation
+ to prevent from congestion."
+ ::= { cosEntry 11 }
+
+ -- End of CoS part
+
+
+--*******************************************************************
+--* GFP part
+--*******************************************************************
+
+ GfpFailure ::= INTEGER
+ {
+ none(0),
+ oofd(1),
+ lofd(2),
+ fdsc(3)
+ }
+
+ GfpState ::= INTEGER(0..2147483647)
+ -- {
+ -- none(0),
+ -- (1),
+ -- (2),
+ -- (3)
+ -- }
+
+ gfpNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "ports Number of the Gfp layer.
+ = number of entries in gfpTable "
+ ::= { gige 50 }
+
+ gfpTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF GfpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of gfp port in the equipment."
+ ::= { gige 51 }
+
+ gfpEntry OBJECT-TYPE
+ SYNTAX GfpEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular gfp port of the equipment."
+ INDEX { gfpIndex }
+ ::= { gfpTable 1 }
+
+ GfpEntry ::= SEQUENCE {
+ gfpIndex INTEGER, -- channelIndex
+ gfpHCInPkts Counter64,
+ gfpHCInIdlePkts Counter64,
+ gfpHCInCorruptedPkts Counter64,
+ gfpHCInErrors Counter64,
+ gfpHCInCorrectedPkts Counter64,
+ gfpHCFCSErrors Counter64,
+ gfpHCInOctets Counter64,
+ gfpHCOutPkts Counter64,
+ gfpHCOutIdlePkts Counter64,
+ gfpHCOutOctets Counter64,
+ gfpIdleRate INTEGER,
+ gfpSendingRate INTEGER,
+ gfpState GfpState,
+ gfpAdminStatus INTEGER,
+ gfpOperStatus INTEGER,
+ gfpMonitor SagemBoolean,
+ gfpFailure GfpFailure,
+ gfpSeverity Severity,
+ gfpOOFD Severity,
+ gfpLOFD Severity,
+ gfpFDSC Severity
+ }
+
+ gfpIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular gfp port in the equipment.
+ The value of this index is a constant value assigned to an entry at
+ equipment design time. It is usualy related to harware. Its values are mapped to channelIndex values."
+ ::= { gfpEntry 1 }
+
+ gfpHCInPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " The total number of packets received on the Gfp interface"
+ ::= { gfpEntry 2 }
+
+ gfpHCInIdlePkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " The total number of Idle frames received on the Gfp interface"
+ ::= { gfpEntry 3 }
+
+ gfpHCInCorruptedPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " The total number of mismatched packets received on the Gfp interface."
+ ::= { gfpEntry 4 }
+
+ gfpHCInErrors OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of mismatched packets that have been discarded. "
+ ::= { gfpEntry 5 }
+
+ gfpHCInCorrectedPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of mismatched packets received on the Gfp interface that have been corrected. "
+ ::= { gfpEntry 6 }
+
+ gfpHCFCSErrors OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of frames received on the Gfp interface that are an integral number of octets
+ in length but do not pass the FCS check. "
+ ::= { gfpEntry 7 }
+
+ gfpHCInOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " The total number of Octets received on the Gfp interface"
+ ::= { gfpEntry 8 }
+
+ gfpHCOutPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " The total number of packets transmitted out of the Gfp interface"
+ ::= { gfpEntry 9 }
+
+ gfpHCOutIdlePkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " The total number of Idle frame transmitted out of the Gfp interface"
+ ::= { gfpEntry 10 }
+
+ gfpHCOutOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " The total number of packets transmitted out of the Gfp interface"
+ ::= { gfpEntry 11 }
+
+ gfpIdleRate OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " The received Idle frames rate on a particular gfp port. "
+ ::= { gfpEntry 12 }
+
+ gfpSendingRate OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ " The sent frames rate on a particular gfp port. "
+ ::= { gfpEntry 13 }
+
+ gfpState OBJECT-TYPE
+ SYNTAX GfpState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This field allows to know in which state this gfp port is working."
+ ::= { gfpEntry 14 }
+
+ gfpAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1), -- ready to pass packets
+ down(2),
+ testing(3) -- in some test mode
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The desired state of the gfp port. The
+ testing(3) state indicates that no operational
+ packets can be passed."
+ ::= { gfpEntry 15 }
+
+ gfpOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ up(1), -- ready to pass packets
+ down(2),
+ testing(3) -- in some test mode
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current operational state of the gfp port.
+ The testing(3) state indicates that no operational
+ packets can be passed."
+ ::= { gfpEntry 16 }
+
+ gfpMonitor OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to false, the failure detection
+ is stopped for this gfp port."
+ ::= { gfpEntry 17 }
+
+ gfpFailure OBJECT-TYPE
+ SYNTAX GfpFailure
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active failures on channel"
+ ::= { gfpEntry 18 }
+
+ gfpSeverity OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to failure severity for gfp port."
+ ::= { gfpEntry 19 }
+
+ gfpOOFD OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associated with Out of Frame Delineation failure
+ for gfp port."
+ ::= { gfpEntry 20 }
+
+ gfpLOFD OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associated with Loss Of Frame Delineation failure
+ for gfp port."
+ ::= { gfpEntry 21 }
+
+ gfpFDSC OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Severity associated with Frame Delineation State Change failure
+ for gfp port."
+ ::= { gfpEntry 22 }
+-- End of GFP part
+
+
+--*******************************************************************
+--* PAUSE part
+--*******************************************************************
+
+ PauseFailure ::= INTEGER
+ {
+ none(0),
+ pauseModeRejected(1)
+ }
+
+ pauseNumber OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of ports in the equipment which accept Pause mechanism
+ = number of entries in pauseTable "
+ ::= { gige 60 }
+
+ pauseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PauseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "List of Ethernet port in the equipment which accept Pause mechanism."
+ ::= { gige 61 }
+
+ pauseEntry OBJECT-TYPE
+ SYNTAX PauseEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A particular Ethernet port of the equipment."
+ INDEX { pauseIndex }
+ ::= { pauseTable 1 }
+
+ PauseEntry ::= SEQUENCE {
+ pauseIndex INTEGER, -- Lan ifIndex
+ pauseTime INTEGER,
+ pauseBetweenTime INTEGER,
+ pauseMacSA PhysAddress,
+ pauseMacDA PhysAddress,
+ pauseCHT INTEGER,
+ pauseCLT INTEGER,
+ pauseMonitor SagemBoolean,
+ pauseFailure PauseFailure,
+ pauseSeverity Severity,
+ pauseModeRejected Severity
+ }
+
+ pauseIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value which identify a particular Ethernet Physical port of a gigabitEthernet card.
+ The value of this index is a constant value assigned to an entry at
+ equipment design time. It is usualy related to harware. Its values are mapped to IfIndex values of Lan Ports."
+ ::= { pauseEntry 1 }
+
+ pauseTime OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field allows to set the Time during which the linkPartner stop any transmission. The Unit used is the time slot
+ (= 512 ns)."
+ ::= { pauseEntry 2 }
+
+ pauseBetweenTime OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field allows to set the Time between two Pause Frames transmission. The Unit used is the time slot
+ (= 512 ns)."
+ ::= { pauseEntry 3 }
+
+ pauseMacSA OBJECT-TYPE
+ SYNTAX PhysAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ " The physical address of the Ethernet port.
+ This address is used to fill the SourceAddress field of any Pause Frame which is trasmitted by the LinkPartner."
+ ::= { pauseEntry 4 }
+
+ pauseMacDA OBJECT-TYPE
+ SYNTAX PhysAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ " The physical address used to fill the DestinationAddress field of any Pause Frame which is transmitted by the LinkPartner."
+ ::= { pauseEntry 5 }
+
+ pauseCHT OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field allows to configure the credit High Threshold of Pause mechanism."
+ ::= { pauseEntry 6 }
+
+ pauseCLT OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field allows to configure the credit Low Threshold of Pause mechanism."
+ ::= { pauseEntry 7 }
+
+ pauseMonitor OBJECT-TYPE
+ SYNTAX SagemBoolean
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "When the value of this field is set to false, the failure detection
+ is stopped for this Ethernet port."
+ ::= { pauseEntry 10 }
+
+ pauseFailure OBJECT-TYPE
+ SYNTAX PauseFailure
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active failures in the pause mechanism of the Ethernet port."
+ ::= { pauseEntry 11 }
+
+ pauseSeverity OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A reference to severity associated to the current pause failure."
+ ::= { pauseEntry 12 }
+
+ pauseModeRejected OBJECT-TYPE
+ SYNTAX Severity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This field allows to configure the Severity associated with Pause Mode Rejected failure
+ for Ethernet port."
+ ::= { pauseEntry 13 }
+
+-- End of Pause part
+
+
+END
+
+
+
+