summaryrefslogtreecommitdiff
path: root/MIBS/screenos/NETSCREEN-UAC-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/screenos/NETSCREEN-UAC-MIB')
-rw-r--r--MIBS/screenos/NETSCREEN-UAC-MIB124
1 files changed, 124 insertions, 0 deletions
diff --git a/MIBS/screenos/NETSCREEN-UAC-MIB b/MIBS/screenos/NETSCREEN-UAC-MIB
new file mode 100644
index 0000000..e7de1fd
--- /dev/null
+++ b/MIBS/screenos/NETSCREEN-UAC-MIB
@@ -0,0 +1,124 @@
+-- This module defines enterprise MIBs for UACs
+--
+-- Copyright (c) 1999-2010, Juniper Networks, Inc.
+-- All rights reserved.
+
+NETSCREEN-UAC-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ netscreenUAC
+ FROM NETSCREEN-SMI
+ Integer32, MODULE-IDENTITY, OBJECT-TYPE
+ FROM SNMPv2-SMI
+ DisplayString
+ FROM SNMPv2-TC
+ ;
+
+netscreenUACMibModule MODULE-IDENTITY
+ LAST-UPDATED "201004140000Z" -- Apr 14, 2010
+ ORGANIZATION
+ "Juniper Networks, Inc."
+ CONTACT-INFO
+ "Customer Support
+
+ 1194 North Mathilda Avenue
+ Sunnyvale, California 94089-1206
+ USA
+
+ Tel: 1-800-638-8296
+ E-mail: customerservice@juniper.net
+ HTTP://www.juniper.net"
+ DESCRIPTION
+ "This module defines the object that are used to monitor all
+ UAC"
+ REVISION "201004140000Z" -- Apr 14, 2010
+ DESCRIPTION
+ "Creation Date"
+ ::= { netscreenUAC 0 }
+
+
+nsUACActiveUsers OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Active users on this box, base on auth entry from UAC controler"
+ ::= { netscreenUAC 1 }
+
+
+NsUACControlerStatusEntry ::= SEQUENCE
+{
+ nsUACControlerId Integer32,
+ nsUACControlerName DisplayString,
+ nsUACControlerHost DisplayString,
+ nsUACConnectionStatus Integer32
+}
+
+nsUACControlerStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF NsUACControlerStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "NetScreen UAC controler status table"
+ ::= { netscreenUAC 2}
+
+nsUACControlerStatusEntry OBJECT-TYPE
+ SYNTAX NsUACControlerStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Each entry in the table holds a set of configuration
+ parameters associated with an instance of secure UAC."
+ INDEX
+ { nsUACControlerID}
+ ::= { nsUACControlerStatusTable 1 }
+
+nsUACControlerId OBJECT-TYPE
+ SYNTAX Integer32 (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unique value for UAC table. Its value ranges between 1 and
+ 65535 and may not be contiguous. the index has no other
+ meaning but a pure index"
+ ::= { nsUACControlerStatusEntry 1 }
+
+nsUACControlerName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Secure UAC name."
+ ::= { nsUACControlerStatusEntry 2 }
+
+
+nsUACControlerHost OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Secure UAC name."
+ ::= { nsUACControlerStatusEntry 3 }
+
+nsUACConnectionStatus OBJECT-TYPE
+ SYNTAX Integer32 {
+ disconnected(0),
+ connected(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "UAC controler status table"
+ ::= { nsUACControlerStatusEntry 4 }
+
+nsUACGlobalStatus OBJECT-TYPE
+ SYNTAX Integer32 {
+ disconnected(0),
+ connected(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "To indicate whether there is at least one heathy IC-IE connection"
+ ::= { netscreenUAC 3 }
+END