diff --git a/MIBS/sentry/Sentry3-MIB b/MIBS/sentry/Sentry3-MIB new file mode 100644 index 0000000..066409d --- /dev/null +++ b/MIBS/sentry/Sentry3-MIB @@ -0,0 +1,2365 @@ +--
+-- Copyright(C) 2003-2016 Server Technology, Inc.
+--
+
+ Sentry3-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ MODULE-IDENTITY, NOTIFICATION-TYPE,
+ OBJECT-TYPE, enterprises FROM SNMPv2-SMI
+ DisplayString FROM SNMPv2-TC;
+
+
+ sentry3 MODULE-IDENTITY
+ LAST-UPDATED "201601251630Z" -- 25 January 2016
+ ORGANIZATION "Server Technology, Inc."
+ CONTACT-INFO
+ "Server Technology, Inc.
+ 1040 Sandhill Road
+ Reno, NV 89521
+ Tel: (775) 284-2000
+ Fax: (775) 284-2065
+ Email: mibmaster@servertech.com"
+ DESCRIPTION
+ "This is the MIB module for the third generation of the
+ Sentry product family. This includes the Sentry Remote
+ Power Manager (RPM), Sentry Power Distribution Unit (PDU),
+ Sentry Environmental Monitor (EM), Sentry Smart and
+ Switched Cabinet Distribution Unit (CDU), and Sentry
+ Switched -48 VDC."
+ REVISION "201601251630Z" -- 25 January 2016
+ DESCRIPTION
+ "Adjusted the upper limit of infeedLoadValue to 60000.
+ Adjusted the upper limit of infeedLoadHighThresh to 600.
+ Adjusted the upper limit of infeedCapacity to 600."
+ REVISION "201406251200Z" -- 25 June 2014
+ DESCRIPTION
+ "Adjusted the upper limit of tempHumidSensorTempRecDelta
+ to 54."
+ REVISION "201401161800Z" -- 16 January 2014
+ DESCRIPTION
+ "Added an eventInformationGroup with two new objects:
+ eventStatusText and eventStatusCondition. Added these
+ objects to all traps and updated the trap annotations
+ to use the eventStatusText string value instead of the
+ integer value of the status object in the trap."
+ REVISION "201311250900Z" -- 25 November 2013
+ DESCRIPTION
+ "Added a new object: tempHumidSensorHumidRecDelta."
+ REVISION "201309161000Z" -- 16 September 2013
+ DESCRIPTION
+ "Adjusted the upper limit of infeedLoadValue to 30000.
+ Adjusted the upper limit of infeedLoadHighThresh to 300.
+ Adjusted the upper limit of infeedCapacity to 300.
+ Adjusted the upper limit of branchLoadValue to 4000."
+ REVISION "201302140930Z" -- 14 February 2013
+ DESCRIPTION
+ "Added a branch table with new objects for branch status
+ and current measurements. Added 'branchOnSense' and
+ 'branchLoadSense' bits to infeedCapabilities. Added
+ 'reading', 'offFuse', and 'onFuse' bits to infeedStatus.
+ Added branchStatusEvent and branchLoadEvent notifications.
+ Added 'outOfBalance' to the list of error conditions
+ enumerated by the towerStatus object."
+ REVISION "201211071400Z" -- 7 November 2012
+ DESCRIPTION
+ "Adjusted the upper limit of systemVersion to 80. Adjusted
+ the upper limit of infeedOutletCount and outletIndex to 64."
+ REVISION "201204181400Z" -- 18 April 2012
+ DESCRIPTION
+ "Adjusted the upper limit of outletIndex to 32."
+ REVISION "201201041100Z" -- 4 January 2012
+ DESCRIPTION
+ "Added 'nvmFail' to the list of error conditions enumerated
+ by the towerStatus object."
+ REVISION "201107111640Z" -- 11 July 2011
+ DESCRIPTION
+ "Added 'outletControlInhibit' to the list of key-activated
+ features enumerated by the systemFeatures object. Changed
+ the upper limit of tempHumidSensorTempRecDelta to 18 to
+ accommodate the maximum Fahrenheit value."
+ REVISION "201106151300Z" -- 15 June 2011
+ DESCRIPTION
+ "Added a new object: tempHumidSensorTempRecDelta."
+ REVISION "201105051100Z" -- 5 May 2011
+ DESCRIPTION
+ "Added several new objects: systemOutletSeqInterval,
+ systemOutletRebootDelay, systemConfigModifiedCount,
+ outletWakeupState, and outletPostOnDelay. Removed the
+ 'snmpPOPS' feature-key activation requirement from
+ descriptions of POPS objects."
+ REVISION "201007071215Z" -- 7 July 2010
+ DESCRIPTION
+ "Added support for Per-Inlet Power Sensing (PIPS) hardware.
+ Added several new objects: towerVACapacity,
+ towerVACapacityUsed, towerActivePower, towerApparentPower,
+ towerPowerFactor, towerEnergy, towerLineFrequency,
+ infeedReactance, infeedPhaseCurrent, infeedPhaseVoltage,
+ infeedCapacityUsed, infeedLineID, infeedLineToLineID,
+ infeedPhaseID, infeedVACapacity, and infeedVACapacityUsed.
+ Changed the UNITS of infeedEnergy. Adjusted the limits of
+ INTEGER data types for various objects. Updated the
+ descriptions of various infeedTable objects to distinguish
+ between line and phase measurements with three-phase PIPS
+ hardware."
+ REVISION "200903101600Z" -- 10 March 2009
+ DESCRIPTION
+ "Added support for Per-Outlet Power Sensing (POPS) hardware.
+ Added several new objects: systemFeatures, systemFeatureKey,
+ infeedApparentPower, infeedPowerFactor, infeedCrestFactor,
+ infeedEnergy, outletCapacity, outletVoltage, outletPower,
+ outletApparentPower, outletPowerFactor, outletCrestFactor,
+ and outletEnergy. Added 'voltageSense' and 'powerSense'
+ bit definitions to the input feed and outlet capabilities
+ objects. Increased the size of systemVersion to 50."
+ REVISION "200805071520Z" -- 7 May 2008
+ DESCRIPTION
+ "Added systemAreaUnit and systemPowerFactor objects. Renamed
+ the systemWattsPerUnitArea object to systemWattsPerAreaUnit.
+ Changed systemArea from read-only to read-write."
+ REVISION "200707091445Z" -- 9 July 2007
+ DESCRIPTION
+ "Added support for products with fan rotation sensing and
+ internal temperature sensing. Added 'fanSense' and
+ 'tempSense' bit definitions to the tower capabilities
+ object. Added 'fanFail' and 'overTemp' states to the
+ towerStatus object. Modified the description of the
+ towerStatusEvent trap to reflect these additions."
+ REVISION "200701091410Z" -- 9 January 2007
+ DESCRIPTION
+ "Added several new objects: systemArea, systemTotalPower,
+ systemWattsPerUnitArea, towerProductSN, towerModelNumber,
+ towerCapabilities, infeedCapacity, infeedVoltage, and
+ infeedPower. Added six states to the outletControlState
+ object."
+ REVISION "200607201200Z" -- 20 July 2006
+ DESCRIPTION
+ "Changed the upper limit of systemTowerCount from 2 to 4."
+ REVISION "200606120930Z" -- 12 June 2006
+ DESCRIPTION
+ "Added a tempHumidSensorTempScale object to select either
+ Celsius or Fahrenheit as the scale for temperature values.
+ To accommodate the maximum Fahrenheit value, the upper limit
+ of tempHumidSensorTempValue was changed to 2540, and the
+ upper limit of tempHumidSensorTempHighThresh was changed to
+ 254. Removed 'Celsius' from the UNITS clause and description
+ of temperature objects. Added the tempHumidSensorTempScale
+ object to the tempHumidSensorTempEvent trap. Changed the
+ upper limit of towerIndex from 2 to 4, to accommodate new
+ products with additional link capabilities."
+ REVISION "200507271105Z" -- 27 July 2005
+ DESCRIPTION
+ "Changed the upper limit of tempHumidSensorTempLowThresh to
+ 123. Changed the upper limit of tempHumidSensorTempValue
+ to 1235."
+ REVISION "200502181145Z" -- 18 February 2005
+ DESCRIPTION
+ "Added CDU products to the MIB description. Corrected syntax
+ of outletID to specify SIZE(2..4)."
+ REVISION "200501071220Z" -- 7 January 2005
+ DESCRIPTION
+ "Added a 'fusedBranch' bit definition to the outlet
+ capabilities object. Added 'offFuse' and 'onFuse' states
+ to the outlet status object. Modified the descriptions of
+ objects and traps to reflect support for these additions."
+ REVISION "200412091320Z" -- 9 December 2004
+ DESCRIPTION
+ "Corrected spelling errors. Removed product acronyms from the
+ trap annotations."
+ REVISION "200411111200Z" -- 11 November 2004
+ DESCRIPTION
+ "Changed the upper limit of tempHumidSensorTempHighThresh to
+ 123. Renamed systemSerialNumber to systemNICSerialNumber."
+ REVISION "200311201300Z" -- 20 November 2003
+ DESCRIPTION
+ "Changed the MIB description to reflect that there are
+ multiple products in the Sentry product family supported by
+ this MIB."
+ REVISION "200310231900Z" -- 23 October 2003
+ DESCRIPTION
+ "Added annotations to the trap definitions. Added a
+ 'reading' state to the outletStatus object. Renamed
+ 'notificationGroup' to 'sentry3Traps'. Corrected the
+ the description of the tempHumidSensorStatusEvent trap."
+ REVISION "200310021100Z" -- 2 October 2003
+ DESCRIPTION
+ "Added a 'failSafe' bit definition to the infeed capabilities
+ object, and corrected the definition of the 'defaultOff'
+ infeed capabilities bit."
+ REVISION "200308271600Z" -- 27 August 2003
+ DESCRIPTION
+ "Added new bit definitions to the infeed and outlet
+ capabilities objects."
+ REVISION "200303281700Z" -- 28 March 2003
+ DESCRIPTION
+ "Added environmental monitor objects and traps."
+ REVISION "200303271700Z" -- 27 March 2003
+ DESCRIPTION
+ "Initial release."
+ ::= { serverTech 3 }
+
+ serverTech OBJECT IDENTIFIER ::= { enterprises 1718 }
+
+
+--
+-- System Group
+--
+
+ systemGroup OBJECT IDENTIFIER ::= { sentry3 1 }
+
+ systemVersion OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..80))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The firmware version of the system."
+ ::= { systemGroup 1 }
+
+ systemNICSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..8))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The serial number of the network interface card in the
+ system."
+ ::= { systemGroup 2 }
+
+ systemLocation OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The location of the system."
+ ::= { systemGroup 3 }
+
+ systemTowerCount OBJECT-TYPE
+ SYNTAX INTEGER(0..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of towers in the system."
+ ::= { systemGroup 4 }
+
+ systemEnvMonCount OBJECT-TYPE
+ SYNTAX INTEGER(0..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of environmental monitors in the system."
+ ::= { systemGroup 5 }
+
+ systemTotalPower OBJECT-TYPE
+ SYNTAX INTEGER(-1..150000)
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total power consumption of all of the input feeds in the
+ system. A non-negative value indicates the total power
+ consumption in Watts. A negative value indicates that the
+ total power consumption was not available."
+ ::= { systemGroup 6 }
+
+ systemArea OBJECT-TYPE
+ SYNTAX INTEGER(0..1000)
+ UNITS "tenth area units"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The area that the footprint of the system occupies. A
+ non-zero non-negative value indicates the area in tenths of
+ area units as selected by the systemAreaUnit object. A zero
+ or negative value indicates that the area was not available."
+ ::= { systemGroup 7 }
+
+ systemWattsPerAreaUnit OBJECT-TYPE
+ SYNTAX INTEGER(-1..1500000)
+ UNITS "Watts per area unit"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The system Watts per area unit. A non-negative value
+ indicates the power consumption per area unit as selected by
+ the systemAreaUnit object. A negative value indicates that
+ the power consumption per area unit was not available."
+ ::= { systemGroup 8 }
+
+ systemAreaUnit OBJECT-TYPE
+ SYNTAX INTEGER {
+ squareMeter(0),
+ squareFoot(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The unit of area for the systemArea and systemWattsPerAreaUnit
+ objects. If the agent does not support this object, then the
+ unit of area is a square foot."
+ ::= { systemGroup 9 }
+
+ systemPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER(50..100)
+ UNITS "hundredths"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The power factor used in power calculations performed by the
+ system."
+ ::= { systemGroup 10 }
+
+ systemFeatures OBJECT-TYPE
+ SYNTAX BITS {
+ smartLoadShedding(0),
+ snmpPOPS(1),
+ outletControlInhibit(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The key-activated features enabled in the system."
+ ::= { systemGroup 11 }
+
+ systemFeatureKey OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..19))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A valid feature key written to this object will enable a
+ feature in the system. A valid feature key is in the form
+ xxxx-xxxx-xxxx-xxxx. A read of this object returns an
+ empty string."
+ ::= { systemGroup 12 }
+
+ systemOutletSeqInterval OBJECT-TYPE
+ SYNTAX INTEGER(0..15)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The power-on sequencing interval for all outlets."
+ ::= { systemGroup 13 }
+
+ systemOutletRebootDelay OBJECT-TYPE
+ SYNTAX INTEGER(5..600)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The reboot delay for all outlets."
+ ::= { systemGroup 14 }
+
+ systemConfigModifiedCount OBJECT-TYPE
+ SYNTAX INTEGER(0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of times the system configuration has
+ changed."
+ ::= { systemGroup 15 }
+
+--
+-- System Tables
+--
+
+ systemTables OBJECT IDENTIFIER ::= { sentry3 2 }
+
+ --
+ -- Tower Table
+ --
+
+ towerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of towers."
+ ::= { systemTables 1 }
+
+ towerEntry OBJECT-TYPE
+ SYNTAX TowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for the tower table."
+ INDEX { towerIndex }
+ ::= { towerTable 1 }
+
+ TowerEntry ::= SEQUENCE {
+ towerIndex INTEGER,
+ towerID DisplayString,
+ towerName DisplayString,
+ towerStatus INTEGER,
+ towerInfeedCount INTEGER,
+ towerProductSN DisplayString,
+ towerModelNumber DisplayString,
+ towerCapabilities BITS,
+ towerVACapacity INTEGER,
+ towerVACapacityUsed INTEGER,
+ towerActivePower INTEGER,
+ towerApparentPower INTEGER,
+ towerPowerFactor INTEGER,
+ towerEnergy INTEGER,
+ towerLineFrequency INTEGER
+ }
+
+ towerIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..4)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index for the tower table."
+ ::= { towerEntry 1 }
+
+ towerID OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(1))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID of the tower."
+ ::= { towerEntry 2 }
+
+ towerName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..24))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the tower."
+ ::= { towerEntry 3 }
+
+ towerStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ noComm(1),
+ fanFail(2),
+ overTemp(3),
+ nvmFail(4),
+ outOfBalance(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The operational status of the tower."
+ ::= { towerEntry 4 }
+
+ towerInfeedCount OBJECT-TYPE
+ SYNTAX INTEGER(0..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of input feeds on the tower."
+ ::= { towerEntry 5 }
+
+ towerProductSN OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The product serial number of the tower."
+ ::= { towerEntry 6 }
+
+ towerModelNumber OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..24))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The model number of the tower."
+ ::= { towerEntry 7 }
+
+ towerCapabilities OBJECT-TYPE
+ SYNTAX BITS {
+ failSafe(0),
+ fuseSense(1),
+ directCurrent(2),
+ threePhase(3),
+ fanSense(4),
+ tempSense(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The capabilities of the tower."
+ ::= { towerEntry 8 }
+
+ towerVACapacity OBJECT-TYPE
+ SYNTAX INTEGER(-1..50000)
+ UNITS "Volt-Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total apparent power capacity of the tower circuit.
+ A non-negative value indicates the maximum total apparent
+ power in Volt-Amps. A negative value indicates that the
+ total apparent power capacity was not available."
+ ::= { towerEntry 9 }
+
+ towerVACapacityUsed OBJECT-TYPE
+ SYNTAX INTEGER(-1..1500)
+ UNITS "tenth percentage"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The used percentage of the tower circuit total apparent power
+ capacity (towerApparentPower / towerVACapacity x 100). A
+ non-negative value indicates the percentage of capacity used
+ in tenths. A negative value indicates that the percentage of
+ capacity used was not available."
+ ::= { towerEntry 10 }
+
+ towerActivePower OBJECT-TYPE
+ SYNTAX INTEGER(-1..50000)
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total active power consumption of the tower circuit.
+ A non-negative value indicates the total active power
+ consumption in Watts. A negative value indicates that the
+ total active power consumption was not available."
+ ::= { towerEntry 11 }
+
+ towerApparentPower OBJECT-TYPE
+ SYNTAX INTEGER(-1..50000)
+ UNITS "Volt-Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total apparent power consumption of the tower circuit.
+ A non-negative value indicates the total apparent power
+ consumption in Volt-Amps. A negative value indicates that
+ the total apparent power consumption was not available."
+ ::= { towerEntry 12 }
+
+ towerPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER(-1..100)
+ UNITS "hundredths"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The overall power factor of the tower circuit. A non-
+ negative value indicates the overall power factor in
+ hundredths. A negative value indicates that the overall
+ power factor was not able to be measured."
+ ::= { towerEntry 13 }
+
+ towerEnergy OBJECT-TYPE
+ SYNTAX INTEGER(-1..2147483647)
+ UNITS "Kilowatt-Hours"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total energy consumption of the tower circuit. A non-
+ negative value indicates the total energy consumption in
+ Kilowatt-Hours. A negative value indicates that the total
+ energy consumption was not available."
+ ::= { towerEntry 14 }
+
+ towerLineFrequency OBJECT-TYPE
+ SYNTAX INTEGER(-1..60)
+ UNITS "Hertz"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The frequency of the input feed line voltage. A non-
+ negative value indicates the frequency in Hertz. A negative
+ value indicates that the frequency was not available."
+ ::= { towerEntry 15 }
+
+ --
+ -- Input Feed Table
+ --
+
+ infeedTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF InfeedEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of input feeds."
+ ::= { systemTables 2 }
+
+ infeedEntry OBJECT-TYPE
+ SYNTAX InfeedEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for the input feed table."
+ INDEX { towerIndex, infeedIndex }
+ ::= { infeedTable 1 }
+
+ InfeedEntry ::= SEQUENCE {
+ infeedIndex INTEGER,
+ infeedID DisplayString,
+ infeedName DisplayString,
+ infeedCapabilities BITS,
+ infeedStatus INTEGER,
+ infeedLoadStatus INTEGER,
+ infeedLoadValue INTEGER,
+ infeedLoadHighThresh INTEGER,
+ infeedOutletCount INTEGER,
+ infeedCapacity INTEGER,
+ infeedVoltage INTEGER,
+ infeedPower INTEGER,
+ infeedApparentPower INTEGER,
+ infeedPowerFactor INTEGER,
+ infeedCrestFactor INTEGER,
+ infeedEnergy INTEGER,
+ infeedReactance INTEGER,
+ infeedPhaseVoltage INTEGER,
+ infeedPhaseCurrent INTEGER,
+ infeedCapacityUsed INTEGER,
+ infeedLineID DisplayString,
+ infeedLineToLineID DisplayString,
+ infeedPhaseID DisplayString,
+ infeedVACapacity INTEGER,
+ infeedVACapacityUsed INTEGER
+ }
+
+ infeedIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..4)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index for the input feed table."
+ ::= { infeedEntry 1 }
+
+ infeedID OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(2))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID of the input feed."
+ ::= { infeedEntry 2 }
+
+ infeedName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..24))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the input feed."
+ ::= { infeedEntry 3 }
+
+ infeedCapabilities OBJECT-TYPE
+ SYNTAX BITS {
+ onSense(0),
+ loadSense(1),
+ powerControl(2),
+ failSafe(3),
+ defaultOff(4),
+ voltageSense(5),
+ powerSense(6),
+ branchOnSense(7),
+ branchLoadSense(8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The capabilities of the input feed."
+ ::= { infeedEntry 4 }
+
+ infeedStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ on(1),
+ offWait(2),
+ onWait(3),
+ offError(4),
+ onError(5),
+ noComm(6),
+ reading(7),
+ offFuse(8),
+ onFuse(9)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the input feed line. If the infeedCapabilities
+ 'onSense' bit is TRUE, then all of the states are supported
+ and indicate the sensed state of the input feed. If the
+ infeedCapabilities 'onSense' bit is FALSE, then only the
+ 'on' and 'noComm' states are supported, and 'on' indicates
+ a derived state, not a sensed state."
+ ::= { infeedEntry 5 }
+
+ infeedLoadStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ notOn(1),
+ reading(2),
+ loadLow(3),
+ loadHigh(4),
+ overLoad(5),
+ readError(6),
+ noComm(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the load measured on the input feed line. If
+ the infeedCapabilities 'loadSense' bit is TRUE, then all of
+ the states are supported. If the infeedCapabilities
+ 'loadSense' bit is FALSE, then only the 'normal' and 'noComm'
+ states are supported."
+ ::= { infeedEntry 6 }
+
+ infeedLoadValue OBJECT-TYPE
+ SYNTAX INTEGER(-1..60000)
+ UNITS "hundredth Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The load measured on the input feed line. A non-negative
+ value indicates the measured load in hundredths of Amps. A
+ negative value indicates that a load value was not able to
+ be measured."
+ ::= { infeedEntry 7 }
+
+ infeedLoadHighThresh OBJECT-TYPE
+ SYNTAX INTEGER(0..600)
+ UNITS "Amps"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The load high threshold value of the input feed line in Amps."
+ ::= { infeedEntry 8 }
+
+ infeedOutletCount OBJECT-TYPE
+ SYNTAX INTEGER(0..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of controlled and/or monitored outlets on the
+ input feed."
+ ::= { infeedEntry 9 }
+
+ infeedCapacity OBJECT-TYPE
+ SYNTAX INTEGER(-1..600)
+ UNITS "Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The load capacity of the input feed line. A non-negative
+ value indicates the maximum load in Amps. A negative
+ value indicates that the capacity was not available."
+ ::= { infeedEntry 10 }
+
+ infeedVoltage OBJECT-TYPE
+ SYNTAX INTEGER(-1..4800)
+ UNITS "tenth Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The line-to-line voltage of the input feed. A non-negative
+ value indicates the voltage in tenths of Volts. A negative
+ value indicates that the voltage was not available."
+ ::= { infeedEntry 11 }
+
+ infeedPower OBJECT-TYPE
+ SYNTAX INTEGER(-1..25000)
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The active power consumption of the input feed phase. A non-
+ negative value indicates the active power consumption in
+ Watts. A negative value indicates that the active power
+ consumption was not available."
+ ::= { infeedEntry 12 }
+
+ infeedApparentPower OBJECT-TYPE
+ SYNTAX INTEGER(-1..25000)
+ UNITS "Volt-Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The apparent power consumption of the input feed phase. A
+ non-negative value indicates the apparent power consumption
+ in Volt-Amps. A negative value indicates that the apparent
+ power consumption was not available."
+ ::= { infeedEntry 13 }
+
+ infeedPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER(-1..100)
+ UNITS "hundredths"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power factor of the input feed phase. A non-negative
+ value indicates the power factor in hundredths. A negative
+ value indicates that the power factor was not able to be
+ measured."
+ ::= { infeedEntry 14 }
+
+ infeedCrestFactor OBJECT-TYPE
+ SYNTAX INTEGER(-1..1000)
+ UNITS "tenths"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The crest factor for the load of the input feed phase. A
+ non-negative value indicates the crest factor in tenths. A
+ negative value indicates that the crest factor was not able
+ to be measured."
+ ::= { infeedEntry 15 }
+
+ infeedEnergy OBJECT-TYPE
+ SYNTAX INTEGER(-1..2147483647)
+ UNITS "tenth Kilowatt-Hours"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The energy consumption of the input feed phase. A non-
+ negative value indicates the energy consumption in tenths of
+ Kilowatt-Hours. A negative value indicates that the energy
+ consumption was not available."
+ ::= { infeedEntry 16 }
+
+ infeedReactance OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ capacitive(1),
+ inductive(2),
+ resistive(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The characterization of the phase relation between the
+ voltage and current of the input feed phase."
+ ::= { infeedEntry 17 }
+
+ infeedPhaseVoltage OBJECT-TYPE
+ SYNTAX INTEGER(-1..2640)
+ UNITS "tenth Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage measured for the input feed phase. A non-
+ negative value indicates the voltage in tenths of Volts. A
+ negative value indicates that the voltage was not available."
+ ::= { infeedEntry 18 }
+
+ infeedPhaseCurrent OBJECT-TYPE
+ SYNTAX INTEGER(-1..25500)
+ UNITS "hundredth Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current measured for the input feed phase. A non-
+ negative value indicates the measured load in hundredths of
+ Amps. A negative value indicates that a load value was not
+ able to be measured."
+ ::= { infeedEntry 19 }
+
+ infeedCapacityUsed OBJECT-TYPE
+ SYNTAX INTEGER(-1..1500)
+ UNITS "tenth percentage"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The used percentage of the input feed line load capacity
+ (infeedLoadValue / infeedCapacity x 100). A non-negative
+ value indicates the percentage of capacity used in tenths.
+ A negative value indicates that the percentage of capacity
+ used was not available."
+ ::= { infeedEntry 20 }
+
+ infeedLineID OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..4))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID of the input feed line."
+ ::= { infeedEntry 21 }
+
+ infeedLineToLineID OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..7))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The line-to-line ID of the input feed."
+ ::= { infeedEntry 22 }
+
+ infeedPhaseID OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..6))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID of the input feed phase."
+ ::= { infeedEntry 23 }
+
+ infeedVACapacity OBJECT-TYPE
+ SYNTAX INTEGER(-1..25000)
+ UNITS "Volt-Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The apparent power capacity of the input feed circuit. A
+ non-negative value indicates the maximum apparent power in
+ Volt-Amps. A negative value indicates that the apparent
+ power capacity was not available."
+ ::= { infeedEntry 24 }
+
+ infeedVACapacityUsed OBJECT-TYPE
+ SYNTAX INTEGER(-1..1500)
+ UNITS "tenth percentage"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The used percentage of the input feed circuit apparent power
+ capacity (infeedApparentPower / infeedVACapacity x 100). A
+ non-negative value indicates the percentage of capacity used
+ in tenths. A negative value indicates that the percentage of
+ capacity used was not available."
+ ::= { infeedEntry 25 }
+
+ --
+ -- Outlet Table
+ --
+
+ outletTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of outlets."
+ ::= { systemTables 3 }
+
+ outletEntry OBJECT-TYPE
+ SYNTAX OutletEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for the outlet table."
+ INDEX { towerIndex, infeedIndex, outletIndex }
+ ::= { outletTable 1 }
+
+ OutletEntry ::= SEQUENCE {
+ outletIndex INTEGER,
+ outletID DisplayString,
+ outletName DisplayString,
+ outletCapabilities BITS,
+ outletStatus INTEGER,
+ outletLoadStatus INTEGER,
+ outletLoadValue INTEGER,
+ outletLoadLowThresh INTEGER,
+ outletLoadHighThresh INTEGER,
+ outletControlState INTEGER,
+ outletControlAction INTEGER,
+ outletCapacity INTEGER,
+ outletVoltage INTEGER,
+ outletPower INTEGER,
+ outletApparentPower INTEGER,
+ outletPowerFactor INTEGER,
+ outletCrestFactor INTEGER,
+ outletEnergy INTEGER,
+ outletWakeupState INTEGER,
+ outletPostOnDelay INTEGER
+ }
+
+ outletIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..64)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index for the outlet table."
+ ::= { outletEntry 1 }
+
+ outletID OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(2..4))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID of the outlet."
+ ::= { outletEntry 2 }
+
+ outletName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..24))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the outlet."
+ ::= { outletEntry 3 }
+
+ outletCapabilities OBJECT-TYPE
+ SYNTAX BITS {
+ onSense(0),
+ loadSense(1),
+ powerControl(2),
+ shutdown(3),
+ defaultOn(4),
+ ownInfeed(5),
+ fusedBranch(6),
+ voltageSense(7),
+ powerSense(8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The capabilities of the outlet."
+ ::= { outletEntry 4 }
+
+ outletStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ on(1),
+ offWait(2),
+ onWait(3),
+ offError(4),
+ onError(5),
+ noComm(6),
+ reading(7),
+ offFuse(8),
+ onFuse(9)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the outlet. If the outletCapabilities
+ 'onSense' bit is TRUE, then the state indicates the sensed
+ state of the outlet, not a derived state, and 'offError'
+ and 'onError' are supported to indicate a mismatch between
+ the control and sensed state. If the outletCapabilities
+ 'fusedBranch' bit is TRUE, then the outlet is on a fused
+ branch circuit that can detect the fuse state, and 'offFuse'
+ and 'onFuse' are supported to indicate a fuse error."
+ ::= { outletEntry 5 }
+
+ outletLoadStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ notOn(1),
+ reading(2),
+ loadLow(3),
+ loadHigh(4),
+ overLoad(5),
+ readError(6),
+ noComm(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the load measured on the outlet. If the
+ outletCapabilities 'loadSense' bit is TRUE, then all of the
+ states are supported. If the outletCapabilities 'loadSense'
+ bit is FALSE, then only the 'normal' and 'noComm' states are
+ supported."
+ ::= { outletEntry 6 }
+
+ outletLoadValue OBJECT-TYPE
+ SYNTAX INTEGER(-1..25500)
+ UNITS "hundredth Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The load measured on the outlet. A non-negative value
+ indicates the measured load in hundredths of Amps. A
+ negative value indicates that a load value was not able to
+ be measured."
+ ::= { outletEntry 7 }
+
+ outletLoadLowThresh OBJECT-TYPE
+ SYNTAX INTEGER(0..255)
+ UNITS "Amps"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The load low threshold value of the outlet in Amps."
+ ::= { outletEntry 8 }
+
+ outletLoadHighThresh OBJECT-TYPE
+ SYNTAX INTEGER(0..255)
+ UNITS "Amps"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The load high threshold value of the outlet in Amps."
+ ::= { outletEntry 9 }
+
+ outletControlState OBJECT-TYPE
+ SYNTAX INTEGER {
+ idleOff(0),
+ idleOn(1),
+ wakeOff(2),
+ wakeOn(3),
+ off(4),
+ on(5),
+ lockedOff(6),
+ lockedOn(7),
+ reboot(8),
+ shutdown(9),
+ pendOn(10),
+ pendOff(11),
+ minimumOff(12),
+ minimumOn(13),
+ eventOff(14),
+ eventOn(15),
+ eventReboot(16),
+ eventShutdown(17)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The control state of the outlet. The supported states are
+ dependent upon the outletCapabilities 'powerControl' and
+ 'shutdown' bits, as well as the supported features of the
+ firmware version."
+ ::= { outletEntry 10 }
+
+ outletControlAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0),
+ on(1),
+ off(2),
+ reboot(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "An action to change the control state of the outlet. If
+ the outletCapabilities 'powerControl' bit is TRUE, then the
+ 'on', 'off', and 'reboot' actions can be used to change the
+ control state of the outlet. If the outletCapabilities
+ 'powerControl' bit is FALSE, then the actions have no
+ effect."
+ ::= { outletEntry 11 }
+
+ outletCapacity OBJECT-TYPE
+ SYNTAX INTEGER(-1..255)
+ UNITS "Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The load capacity of the outlet. A non-negative value
+ indicates the maximum load in Amps. A negative value
+ indicates that the capacity was not available."
+ ::= { outletEntry 12 }
+
+ outletVoltage OBJECT-TYPE
+ SYNTAX INTEGER(-1..2640)
+ UNITS "tenth Volts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The voltage of the outlet. A non-negative value indicates
+ the voltage in tenths of Volts. A negative value indicates
+ that the voltage was not available."
+ ::= { outletEntry 13 }
+
+ outletPower OBJECT-TYPE
+ SYNTAX INTEGER(-1..10000)
+ UNITS "Watts"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The active power consumption of the device plugged into the
+ outlet. A non-negative value indicates the active power
+ consumption in Watts. A negative value indicates that the
+ active power consumption was not available."
+ ::= { outletEntry 14 }
+
+ outletApparentPower OBJECT-TYPE
+ SYNTAX INTEGER(-1..10000)
+ UNITS "Volt-Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The apparent power consumption of the device plugged into
+ the outlet. A non-negative value indicates the apparent
+ power consumption in Volt-Amps. A negative value indicates
+ that the apparent power consumption was not available."
+ ::= { outletEntry 15 }
+
+ outletPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER(-1..100)
+ UNITS "hundredths"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power factor of the device plugged into the outlet. A
+ non-negative value indicates the power factor in hundredths.
+ A negative value indicates that the power factor was not able
+ to be measured."
+ ::= { outletEntry 16 }
+
+ outletCrestFactor OBJECT-TYPE
+ SYNTAX INTEGER(-1..1000)
+ UNITS "tenths"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The crest factor for the load of the device plugged into the
+ outlet. A non-negative value indicates the crest factor in
+ tenths. A negative value indicates that the crest factor
+ was not able to be measured."
+ ::= { outletEntry 17 }
+
+ outletEnergy OBJECT-TYPE
+ SYNTAX INTEGER(-1..2147483647)
+ UNITS "Watt-Hours"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The energy consumption of the device plugged into the outlet.
+ A non-negative value indicates the energy consumption in
+ Watt-Hours. A negative value indicates that the energy
+ consumption was not available."
+ ::= { outletEntry 18 }
+
+ outletWakeupState OBJECT-TYPE
+ SYNTAX INTEGER {
+ last(1),
+ off(2),
+ on(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The wakeup state of the outlet."
+ ::= { outletEntry 19 }
+
+ outletPostOnDelay OBJECT-TYPE
+ SYNTAX INTEGER(0..900)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The post-on delay of the outlet."
+ ::= { outletEntry 20 }
+
+ --
+ -- Environmental Monitor Table
+ --
+
+ envMonTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EnvMonEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of environmental monitors."
+ ::= { systemTables 4 }
+
+ envMonEntry OBJECT-TYPE
+ SYNTAX EnvMonEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for the environmental monitor table."
+ INDEX { envMonIndex }
+ ::= { envMonTable 1 }
+
+ EnvMonEntry ::= SEQUENCE {
+ envMonIndex INTEGER,
+ envMonID DisplayString,
+ envMonName DisplayString,
+ envMonStatus INTEGER,
+ envMonWaterSensorName DisplayString,
+ envMonWaterSensorStatus INTEGER,
+ envMonADCName DisplayString,
+ envMonADCStatus INTEGER,
+ envMonADCCount INTEGER,
+ envMonADCLowThresh INTEGER,
+ envMonADCHighThresh INTEGER,
+ envMonTempHumidSensorCount INTEGER,
+ envMonContactClosureCount INTEGER
+ }
+
+ envMonIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..4)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index for the environmental monitor table."
+ ::= { envMonEntry 1 }
+
+ envMonID OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(1))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID of the environmental monitor."
+ ::= { envMonEntry 2 }
+
+ envMonName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..24))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the environmental monitor."
+ ::= { envMonEntry 3 }
+
+ envMonStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ noComm(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The operational status of the environmental monitor."
+ ::= { envMonEntry 4 }
+
+ envMonWaterSensorName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..24))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the water sensor."
+ ::= { envMonEntry 5 }
+
+ envMonWaterSensorStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ alarm(1),
+ noComm(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the water sensor."
+ ::= { envMonEntry 6 }
+
+ envMonADCName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..24))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the analog-to-digital converter."
+ ::= { envMonEntry 7 }
+
+ envMonADCStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ reading(1),
+ countLow(2),
+ countHigh(3),
+ readError(4),
+ noComm(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the analog-to-digital converter."
+ ::= { envMonEntry 8 }
+
+ envMonADCCount OBJECT-TYPE
+ SYNTAX INTEGER(-1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The 8-bit count value from the analog-to-digital converter.
+ A non-negative value indicates the digital value retrieved
+ from the ADC. A negative value indicates that a digital
+ value was not able to be retrieved."
+ ::= { envMonEntry 9 }
+
+ envMonADCLowThresh OBJECT-TYPE
+ SYNTAX INTEGER(0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The 8-bit count low threshold value of the analog-to-digital
+ converter."
+ ::= { envMonEntry 10 }
+
+ envMonADCHighThresh OBJECT-TYPE
+ SYNTAX INTEGER(0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The 8-bit count high threshold value of the analog-to-digital
+ converter."
+ ::= { envMonEntry 11 }
+
+ envMonTempHumidSensorCount OBJECT-TYPE
+ SYNTAX INTEGER(0..2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of temperature/humidity sensors on the
+ environmental monitor."
+ ::= { envMonEntry 12 }
+
+ envMonContactClosureCount OBJECT-TYPE
+ SYNTAX INTEGER(0..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of contact closures on the environmental
+ monitor."
+ ::= { envMonEntry 13 }
+
+ --
+ -- Temperature/Humidity Sensor Table
+ --
+
+ tempHumidSensorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TempHumidSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of temperature/humidity sensors."
+ ::= { systemTables 5 }
+
+ tempHumidSensorEntry OBJECT-TYPE
+ SYNTAX TempHumidSensorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for the temperature/humidity sensor table."
+ INDEX { envMonIndex, tempHumidSensorIndex }
+ ::= { tempHumidSensorTable 1 }
+
+ TempHumidSensorEntry ::= SEQUENCE {
+ tempHumidSensorIndex INTEGER,
+ tempHumidSensorID DisplayString,
+ tempHumidSensorName DisplayString,
+ tempHumidSensorStatus INTEGER,
+ tempHumidSensorTempStatus INTEGER,
+ tempHumidSensorTempValue INTEGER,
+ tempHumidSensorTempLowThresh INTEGER,
+ tempHumidSensorTempHighThresh INTEGER,
+ tempHumidSensorHumidStatus INTEGER,
+ tempHumidSensorHumidValue INTEGER,
+ tempHumidSensorHumidLowThresh INTEGER,
+ tempHumidSensorHumidHighThresh INTEGER,
+ tempHumidSensorTempScale INTEGER,
+ tempHumidSensorTempRecDelta INTEGER,
+ tempHumidSensorHumidRecDelta INTEGER
+ }
+
+ tempHumidSensorIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..2)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index for the temperature/humidity sensor table."
+ ::= { tempHumidSensorEntry 1 }
+
+ tempHumidSensorID OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(2))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID of the temperature/humidity sensor."
+ ::= { tempHumidSensorEntry 2 }
+
+ tempHumidSensorName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..24))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the temperature/humidity sensor."
+ ::= { tempHumidSensorEntry 3 }
+
+ tempHumidSensorStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ found(0),
+ notFound(1),
+ lost(2),
+ noComm(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The operational status of the temperature/humidity sensor."
+ ::= { tempHumidSensorEntry 4 }
+
+ tempHumidSensorTempStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ notFound(1),
+ reading(2),
+ tempLow(3),
+ tempHigh(4),
+ readError(5),
+ lost(6),
+ noComm(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the temperature sensor."
+ ::= { tempHumidSensorEntry 5 }
+
+ tempHumidSensorTempValue OBJECT-TYPE
+ SYNTAX INTEGER(-1..2540)
+ UNITS "tenth degrees"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The temperature measured by the sensor. A non-negative value
+ indicates the measured temperature in tenths of degrees, using
+ the scale selected by tempHumidSensorTempScale. If the agent
+ does not support the tempHumidSensorTempScale object, then the
+ temperature scale used is Celsius. A negative value indicates
+ that a temperature value was not able to be measured."
+ ::= { tempHumidSensorEntry 6 }
+
+ tempHumidSensorTempLowThresh OBJECT-TYPE
+ SYNTAX INTEGER(0..254)
+ UNITS "degrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The temperature low threshold value of the sensor in degrees,
+ using the scale selected by tempHumidSensorTempScale. If the
+ agent does not support the tempHumidSensorTempScale object,
+ then the temperature scale used is Celsius."
+ ::= { tempHumidSensorEntry 7 }
+
+ tempHumidSensorTempHighThresh OBJECT-TYPE
+ SYNTAX INTEGER(0..254)
+ UNITS "degrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The temperature high threshold value of the sensor in degrees,
+ using the scale selected by tempHumidSensorTempScale. If the
+ agent does not support the tempHumidSensorTempScale object,
+ then the temperature scale used is Celsius."
+ ::= { tempHumidSensorEntry 8 }
+
+ tempHumidSensorHumidStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ notFound(1),
+ reading(2),
+ humidLow(3),
+ humidHigh(4),
+ readError(5),
+ lost(6),
+ noComm(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the humidity sensor."
+ ::= { tempHumidSensorEntry 9 }
+
+ tempHumidSensorHumidValue OBJECT-TYPE
+ SYNTAX INTEGER(-1..100)
+ UNITS "percentage relative humidity"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The humidity measured by the sensor. A non-negative value
+ indicates the measured humidity in percentage relative
+ humidity. A negative value indicates that a humidity value
+ was not able to be measured."
+ ::= { tempHumidSensorEntry 10 }
+
+ tempHumidSensorHumidLowThresh OBJECT-TYPE
+ SYNTAX INTEGER(0..100)
+ UNITS "percentage relative humidity"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The humidity low threshold value of the sensor in percentage
+ relative humidity."
+ ::= { tempHumidSensorEntry 11 }
+
+ tempHumidSensorHumidHighThresh OBJECT-TYPE
+ SYNTAX INTEGER(0..100)
+ UNITS "percentage relative humidity"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The humidity low threshold value of the sensor in percentage
+ relative humidity."
+ ::= { tempHumidSensorEntry 12 }
+
+ tempHumidSensorTempScale OBJECT-TYPE
+ SYNTAX INTEGER {
+ celsius(0),
+ fahrenheit(1)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The scale used for temperature values. This is a global
+ setting for all temperature values in the system. If the
+ agent does not support this object, then the temperature
+ scale used is Celsius."
+ ::= { tempHumidSensorEntry 13 }
+
+ tempHumidSensorTempRecDelta OBJECT-TYPE
+ SYNTAX INTEGER(0..54)
+ UNITS "degrees"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The temperature recovery delta (hysteresis) value of the
+ sensor in degrees, using the scale selected by
+ tempHumidSensorTempScale."
+ ::= { tempHumidSensorEntry 14 }
+
+ tempHumidSensorHumidRecDelta OBJECT-TYPE
+ SYNTAX INTEGER(0..20)
+ UNITS "percentage relative humidity"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The humidity recovery delta (hysteresis) value of the
+ sensor in percentage relative humidity."
+ ::= { tempHumidSensorEntry 15 }
+
+ --
+ -- Contact Closure Table
+ --
+
+ contactClosureTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ContactClosureEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of contact closures."
+ ::= { systemTables 6 }
+
+ contactClosureEntry OBJECT-TYPE
+ SYNTAX ContactClosureEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for the contact closure table."
+ INDEX { envMonIndex, contactClosureIndex }
+ ::= { contactClosureTable 1 }
+
+ ContactClosureEntry ::= SEQUENCE {
+ contactClosureIndex INTEGER,
+ contactClosureID DisplayString,
+ contactClosureName DisplayString,
+ contactClosureStatus INTEGER
+ }
+
+ contactClosureIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..4)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index for the contact closure table."
+ ::= { contactClosureEntry 1 }
+
+ contactClosureID OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(2))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID of the contact closure."
+ ::= { contactClosureEntry 2 }
+
+ contactClosureName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..24))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the contact closure."
+ ::= { contactClosureEntry 3 }
+
+ contactClosureStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ alarm(1),
+ noComm(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the contact closure."
+ ::= { contactClosureEntry 4 }
+
+ --
+ -- Branch Table
+ --
+
+ branchTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BranchEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of branches."
+ ::= { systemTables 7 }
+
+ branchEntry OBJECT-TYPE
+ SYNTAX BranchEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Row definition for the branch table."
+ INDEX { towerIndex, infeedIndex, branchIndex }
+ ::= { branchTable 1 }
+
+ BranchEntry ::= SEQUENCE {
+ branchIndex INTEGER,
+ branchID DisplayString,
+ branchName DisplayString,
+ branchCapabilities BITS,
+ branchStatus INTEGER,
+ branchLoadStatus INTEGER,
+ branchLoadValue INTEGER,
+ branchLoadHighThresh INTEGER,
+ branchCapacity INTEGER
+ }
+
+ branchIndex OBJECT-TYPE
+ SYNTAX INTEGER(0..4)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index for the branch table."
+ ::= { branchEntry 1 }
+
+ branchID OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(3))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID of the branch."
+ ::= { branchEntry 2 }
+
+ branchName OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..24))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The name of the branch."
+ ::= { branchEntry 3 }
+
+ branchCapabilities OBJECT-TYPE
+ SYNTAX BITS {
+ onSense(0),
+ loadSense(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The capabilities of the branch."
+ ::= { branchEntry 4 }
+
+ branchStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ off(0),
+ on(1),
+ offWait(2),
+ onWait(3),
+ offError(4),
+ onError(5),
+ noComm(6),
+ reading(7),
+ offFuse(8),
+ onFuse(9)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the branch."
+ ::= { branchEntry 5 }
+
+ branchLoadStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(0),
+ notOn(1),
+ reading(2),
+ loadLow(3),
+ loadHigh(4),
+ overLoad(5),
+ readError(6),
+ noComm(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of the load measured on the branch."
+ ::= { branchEntry 6 }
+
+ branchLoadValue OBJECT-TYPE
+ SYNTAX INTEGER(-1..4000)
+ UNITS "hundredth Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The load measured on the branch. A non-negative
+ value indicates the measured load in hundredths of Amps. A
+ negative value indicates that a load value was not able to
+ be measured."
+ ::= { branchEntry 7 }
+
+ branchLoadHighThresh OBJECT-TYPE
+ SYNTAX INTEGER(0..40)
+ UNITS "Amps"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The load high threshold value of the branch in Amps."
+ ::= { branchEntry 8 }
+
+ branchCapacity OBJECT-TYPE
+ SYNTAX INTEGER(-1..40)
+ UNITS "Amps"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The load capacity of the branch. A non-negative value
+ indicates the maximum load in Amps. A negative value
+ indicates that the capacity was not available."
+ ::= { branchEntry 9 }
+
+--
+-- Event Information Group
+--
+
+ eventInformationGroup OBJECT IDENTIFIER ::= { sentry3 99 }
+
+ eventStatusText OBJECT-TYPE
+ SYNTAX DisplayString(SIZE(0..20))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The text representation of the enumerated integer value of
+ the status object included in a trap. The value of this
+ object is set only when sent with a trap. A get of this
+ object will return a NULL string."
+ ::= { eventInformationGroup 1 }
+
+ eventStatusCondition OBJECT-TYPE
+ SYNTAX INTEGER {
+ nonError(0),
+ error(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The condition of the enumerated integer value of the status
+ object included in a trap. The value of this object is set
+ only when sent with a trap. A get of this object will
+ return zero."
+ ::= { eventInformationGroup 2 }
+
+--
+-- Notifications
+--
+
+ sentry3Traps OBJECT IDENTIFIER ::= { sentry3 100 }
+
+ events OBJECT IDENTIFIER ::= { sentry3Traps 0 }
+ -- the 0 is for V1 compatibility
+
+ -- Tower Traps
+
+ towerStatusEvent NOTIFICATION-TYPE
+ OBJECTS {
+ systemLocation,
+ towerID,
+ towerName,
+ towerStatus,
+ eventStatusText,
+ eventStatusCondition
+ }
+ STATUS current
+ DESCRIPTION
+ "Tower status event. If enabled, this trap is sent when the
+ towerStatus indicates an error state ('noComm', 'fanFail',
+ 'overTemp', 'nvmFail', or 'outOfBalance'). This trap is
+ repeated periodically while the towerStatus remains in an
+ error state. If the towerStatus returns to a non-error
+ state ('normal'), this trap is sent once more with the
+ non-error towerStatus, and then stops being repeated.
+
+ While the towerStatus indicates a 'noComm' error state, all
+ status and load traps are suppressed for input feeds and
+ outlets on the tower."
+ --#TYPE "Sentry: Tower Status Event."
+ --#SUMMARY "Status of Tower '%s' (%s) is '%s'."
+ --#ARGUMENTS { 2, 1, 4 }
+ --#SEVERITY CRITICAL
+ --#GENERIC 6
+ --#CATEGORY "Error Events"
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 255
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE UNKNOWN
+ ::= { events 1 }
+
+ -- Input Feed Traps
+
+ infeedStatusEvent NOTIFICATION-TYPE
+ OBJECTS {
+ systemLocation,
+ infeedID,
+ infeedName,
+ infeedStatus,
+ eventStatusText,
+ eventStatusCondition
+ }
+ STATUS current
+ DESCRIPTION
+ "Input feed status event. If enabled, this trap is sent when
+ the infeedStatus indicates an error state ('offError',
+ 'onError', 'noComm', 'offFuse', or 'onFuse'). This trap is
+ repeated periodically while the infeedStatus remains in an
+ error state. If the infeedStatus returns to a non-error
+ state ('off' or 'on'), this trap is sent once more with the
+ non-error infeedStatus, and then stops being repeated.
+
+ While the infeedStatus indicates an error state, load
+ traps are suppressed for the input feed, and, if the
+ infeedCapabilities 'failSafe' bit is FALSE, all status and
+ load traps are suppressed for outlets on the input feed."
+ --#TYPE "Sentry: Input Feed Status Event."
+ --#SUMMARY "Status of Input Feed '%s' (%s) is '%s'."
+ --#ARGUMENTS { 2, 1, 4 }
+ --#SEVERITY CRITICAL
+ --#GENERIC 6
+ --#CATEGORY "Error Events"
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 255
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE UNKNOWN
+ ::= { events 2 }
+
+ infeedLoadEvent NOTIFICATION-TYPE
+ OBJECTS {
+ systemLocation,
+ infeedID,
+ infeedName,
+ infeedLoadStatus,
+ infeedLoadValue,
+ infeedLoadHighThresh,
+ eventStatusText,
+ eventStatusCondition
+ }
+ STATUS current
+ DESCRIPTION
+ "Input feed load event. If enabled, this trap is sent when
+ the infeedLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the infeedLoadStatus
+ remains in an error state. If the infeedLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error infeedLoadStatus, and then
+ stops being repeated."
+ --#TYPE "Sentry: Input Feed Load Event."
+ --#SUMMARY "Load Status of Input Feed '%s' (%s) is '%s'."
+ --#ARGUMENTS { 2, 1, 6 }
+ --#SEVERITY CRITICAL
+ --#GENERIC 6
+ --#CATEGORY "Error Events"
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 255
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE UNKNOWN
+ ::= { events 3 }
+
+ -- Outlet Traps
+
+ outletStatusEvent NOTIFICATION-TYPE
+ OBJECTS {
+ systemLocation,
+ outletID,
+ outletName,
+ outletStatus,
+ eventStatusText,
+ eventStatusCondition
+ }
+ STATUS current
+ DESCRIPTION
+ "Outlet status event. If enabled, this trap is sent when the
+ outletStatus indicates an error state ('offError', 'onError',
+ 'noComm', 'offFuse', or 'onFuse'). This trap is repeated
+ periodically while the outletStatus remains in an error state.
+ If the outletStatus returns to a non-error state ('off' or
+ 'on'), this trap is sent once more with the non-error
+ outletStatus, and then stops being repeated.
+
+ While the outletStatus indicates an error state, load traps
+ are suppressed for the outlet."
+ --#TYPE "Sentry: Outlet Status Event."
+ --#SUMMARY "Status of Outlet '%s' (%s) is '%s'."
+ --#ARGUMENTS { 2, 1, 4 }
+ --#SEVERITY CRITICAL
+ --#GENERIC 6
+ --#CATEGORY "Error Events"
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 255
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE UNKNOWN
+ ::= { events 4 }
+
+ outletLoadEvent NOTIFICATION-TYPE
+ OBJECTS {
+ systemLocation,
+ outletID,
+ outletName,
+ outletLoadStatus,
+ outletLoadValue,
+ outletLoadLowThresh,
+ outletLoadHighThresh,
+ eventStatusText,
+ eventStatusCondition
+ }
+ STATUS current
+ DESCRIPTION
+ "Outlet load event. If enabled, this trap is sent when the
+ outletLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the outletLoadStatus
+ remains in an error state. If the outletLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error outletLoadStatus, and then
+ stops being repeated."
+ --#TYPE "Sentry: Outlet Load Event."
+ --#SUMMARY "Load Status of Outlet '%s' (%s) is '%s'."
+ --#ARGUMENTS { 2, 1, 7 }
+ --#SEVERITY CRITICAL
+ --#GENERIC 6
+ --#CATEGORY "Error Events"
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 255
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE UNKNOWN
+ ::= { events 5 }
+
+ outletChangeEvent NOTIFICATION-TYPE
+ OBJECTS {
+ systemLocation,
+ outletID,
+ outletName,
+ outletStatus,
+ outletControlState,
+ eventStatusText,
+ eventStatusCondition
+ }
+ STATUS current
+ DESCRIPTION
+ "Outlet on/off change event. If enabled, this trap is sent
+ when the outletStatus changes from any 'on' state ('on',
+ 'onWait', 'onError', or 'onFuse') to any 'off' state ('off',
+ 'offWait', 'offError', or 'offFuse'), and vice-versa."
+ --#TYPE "Sentry: Outlet Change Event."
+ --#SUMMARY "Outlet '%s' (%s) has changed to '%s'."
+ --#ARGUMENTS { 2, 1, 5 }
+ --#SEVERITY INFORMATIONAL
+ --#GENERIC 6
+ --#CATEGORY "Status Events"
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 255
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE UNKNOWN
+ ::= { events 6 }
+
+ -- Environmental Monitor Traps
+
+ envMonStatusEvent NOTIFICATION-TYPE
+ OBJECTS {
+ systemLocation,
+ envMonID,
+ envMonName,
+ envMonStatus,
+ eventStatusText,
+ eventStatusCondition
+ }
+ STATUS current
+ DESCRIPTION
+ "Environmental monitor status event. If enabled, this trap
+ is sent when the envMonStatus indicates an error state
+ ('noComm'). This trap is repeated periodically while the
+ envMonStatus remains in an error state. If the envMonStatus
+ returns to a non-error state ('normal'), this trap is sent
+ once more with the non-error envMonStatus, and then stops
+ being repeated.
+
+ While the envMonStatus indicates an error state, all status
+ traps are suppressed for the water sensor, ADC, temperature/
+ humidity sensors, and contact closures on the environmental
+ monitor."
+ --#TYPE "Sentry: Environmental Monitor Status Event."
+ --#SUMMARY "Status of Environmental Monitor '%s' (%s) is '%s'."
+ --#ARGUMENTS { 2, 1, 4 }
+ --#SEVERITY CRITICAL
+ --#GENERIC 6
+ --#CATEGORY "Error Events"
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 255
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE UNKNOWN
+ ::= { events 7 }
+
+ envMonWaterSensorEvent NOTIFICATION-TYPE
+ OBJECTS {
+ systemLocation,
+ envMonID,
+ envMonWaterSensorName,
+ envMonWaterSensorStatus,
+ eventStatusText,
+ eventStatusCondition
+ }
+ STATUS current
+ DESCRIPTION
+ "Environmental monitor water sensor event. If enabled, this
+ trap is sent when the envMonWaterSensorStatus indicates an
+ error state ('alarm'). This trap is repeated periodically
+ while the envMonWaterSensorStatus remains in an error state.
+ If the envMonWaterSensorStatus returns to a non-error state
+ ('normal'), this trap is sent once more with the non-error
+ envMonWaterSensorStatus, and then stops being repeated."
+ --#TYPE "Sentry: Water Sensor Event."
+ --#SUMMARY "Status of Water Sensor '%s' (%s) is '%s'."
+ --#ARGUMENTS { 2, 1, 4 }
+ --#SEVERITY CRITICAL
+ --#GENERIC 6
+ --#CATEGORY "Error Events"
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 255
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE UNKNOWN
+ ::= { events 8 }
+
+ envMonADCEvent NOTIFICATION-TYPE
+ OBJECTS {
+ systemLocation,
+ envMonID,
+ envMonADCName,
+ envMonADCStatus,
+ envMonADCCount,
+ envMonADCLowThresh,
+ envMonADCHighThresh,
+ eventStatusText,
+ eventStatusCondition
+ }
+ STATUS current
+ DESCRIPTION
+ "Environmental monitor analog-to-digital converter event.
+ If enabled, this trap is sent when the envMonADCStatus
+ indicates an error state ('countLow' or 'countHigh'). This
+ trap is repeated periodically while the envMonADCStatus
+ remains in an error state. If the envMonADCStatus returns
+ to a non-error state ('normal'), this trap is sent once more
+ with the non-error envMonADCStatus, and then stops being
+ repeated."
+ --#TYPE "Sentry: ADC Event."
+ --#SUMMARY "Status of ADC '%s' (%s) is '%s'."
+ --#ARGUMENTS { 2, 1, 7 }
+ --#SEVERITY CRITICAL
+ --#GENERIC 6
+ --#CATEGORY "Error Events"
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 255
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE UNKNOWN
+ ::= { events 9 }
+
+ tempHumidSensorStatusEvent NOTIFICATION-TYPE
+ OBJECTS {
+ systemLocation,
+ tempHumidSensorID,
+ tempHumidSensorName,
+ tempHumidSensorStatus,
+ eventStatusText,
+ eventStatusCondition
+ }
+ STATUS current
+ DESCRIPTION
+ "Temperature/humidity sensor status event. If enabled, this
+ trap is sent when the tempHumidSensorStatus indicates an
+ error state ('lost'). This trap is repeated periodically
+ while the tempHumidSensorStatus remains in an error state.
+ If the tempHumidSensorStatus returns to a non-error state
+ ('found'), this trap is sent once more with the non-error
+ tempHumidSensorStatus, and then stops being repeated.
+
+ While the tempHumidSensorStatus indicates an error state, all
+ temperature and humidity status traps are suppressed for the
+ temperature/humidity sensor."
+ --#TYPE "Sentry: T/H Sensor Status Event."
+ --#SUMMARY "Status of T/H Sensor '%s' (%s) is '%s'."
+ --#ARGUMENTS { 2, 1, 4 }
+ --#SEVERITY CRITICAL
+ --#GENERIC 6
+ --#CATEGORY "Error Events"
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 255
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE UNKNOWN
+ ::= { events 10 }
+
+ tempHumidSensorTempEvent NOTIFICATION-TYPE
+ OBJECTS {
+ systemLocation,
+ tempHumidSensorID,
+ tempHumidSensorName,
+ tempHumidSensorTempStatus,
+ tempHumidSensorTempValue,
+ tempHumidSensorTempLowThresh,
+ tempHumidSensorTempHighThresh,
+ tempHumidSensorTempScale,
+ eventStatusText,
+ eventStatusCondition
+ }
+ STATUS current
+ DESCRIPTION
+ "Temperature/humidity sensor temperature event. If enabled,
+ this trap is sent when the tempHumidSensorTempStatus
+ indicates an error state ('tempLow' or 'tempHigh').
+ This trap is repeated periodically while the
+ tempHumidSensorTempStatus remains in an error state. If
+ the tempHumidSensorTempStatus returns to a non-error state
+ ('normal'), this trap is sent once more with the non-error
+ tempHumidSensorTempStatus, and then stops being repeated."
+ --#TYPE "Sentry: T/H Sensor Temperature Event."
+ --#SUMMARY "Temperature Status of T/H Sensor '%s' (%s) is '%s'."
+ --#ARGUMENTS { 2, 1, 8 }
+ --#SEVERITY CRITICAL
+ --#GENERIC 6
+ --#CATEGORY "Error Events"
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 255
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE UNKNOWN
+ ::= { events 11 }
+
+ tempHumidSensorHumidEvent NOTIFICATION-TYPE
+ OBJECTS {
+ systemLocation,
+ tempHumidSensorID,
+ tempHumidSensorName,
+ tempHumidSensorHumidStatus,
+ tempHumidSensorHumidValue,
+ tempHumidSensorHumidLowThresh,
+ tempHumidSensorHumidHighThresh,
+ eventStatusText,
+ eventStatusCondition
+ }
+ STATUS current
+ DESCRIPTION
+ "Temperature/humidity sensor humidity event. If enabled,
+ this trap is sent when the tempHumidSensorHumidStatus
+ indicates an error state ('humidLow' or 'humidHigh').
+ This trap is repeated periodically while the
+ tempHumidSensorHumidStatus remains in an error state. If
+ the tempHumidSensorHumidStatus returns to a non-error state
+ ('normal'), this trap is sent once more with the non-error
+ tempHumidSensorHumidStatus, and then stops being repeated."
+ --#TYPE "Sentry: T/H Sensor Humidity Event."
+ --#SUMMARY "Humidity Status of T/H Sensor '%s' (%s) is '%s'."
+ --#ARGUMENTS { 2, 1, 7 }
+ --#SEVERITY CRITICAL
+ --#GENERIC 6
+ --#CATEGORY "Error Events"
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 255
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE UNKNOWN
+ ::= { events 12 }
+
+ contactClosureEvent NOTIFICATION-TYPE
+ OBJECTS {
+ systemLocation,
+ contactClosureID,
+ contactClosureName,
+ contactClosureStatus,
+ eventStatusText,
+ eventStatusCondition
+ }
+ STATUS current
+ DESCRIPTION
+ "Contact closure event. If enabled, this trap is sent when
+ the contactClosureStatus indicates an error state ('alarm').
+ This trap is repeated periodically while the
+ contactClosureStatus remains in an error state. If the
+ contactClosureStatus returns to a non-error state ('normal'),
+ this trap is sent once more with the non-error
+ contactClosureStatus, and then stops being repeated."
+ --#TYPE "Sentry: Contact Closure Event."
+ --#SUMMARY "Status of Contact Closure '%s' (%s) is '%s'."
+ --#ARGUMENTS { 2, 1, 4 }
+ --#SEVERITY CRITICAL
+ --#GENERIC 6
+ --#CATEGORY "Error Events"
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 255
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE UNKNOWN
+ ::= { events 13 }
+
+ -- Branch Traps
+
+ branchStatusEvent NOTIFICATION-TYPE
+ OBJECTS {
+ systemLocation,
+ branchID,
+ branchName,
+ branchStatus,
+ eventStatusText,
+ eventStatusCondition
+ }
+ STATUS current
+ DESCRIPTION
+ "Branch status event. If enabled, this trap is sent when
+ the branchStatus indicates an error state ('offError',
+ 'onError', 'noComm', 'offFuse', or 'onFuse'). This trap
+ is repeated periodically while the branchStatus remains in
+ an error state. If the branchStatus returns to a non-error
+ state ('off' or 'on'), this trap is sent once more with the
+ non-error branchStatus, and then stops being repeated.
+
+ While the branchStatus indicates an error state, load traps
+ are suppressed for the branch."
+ --#TYPE "Sentry: Branch Status Event."
+ --#SUMMARY "Status of Branch '%s' (%s) is '%s'."
+ --#ARGUMENTS { 2, 1, 4 }
+ --#SEVERITY CRITICAL
+ --#GENERIC 6
+ --#CATEGORY "Error Events"
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 255
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE UNKNOWN
+ ::= { events 14 }
+
+ branchLoadEvent NOTIFICATION-TYPE
+ OBJECTS {
+ systemLocation,
+ branchID,
+ branchName,
+ branchLoadStatus,
+ branchLoadValue,
+ branchLoadHighThresh,
+ eventStatusText,
+ eventStatusCondition
+ }
+ STATUS current
+ DESCRIPTION
+ "Branch load event. If enabled, this trap is sent when
+ the branchLoadStatus indicates an error state ('loadLow',
+ 'loadHigh', 'overLoad', 'readError', or 'noComm'). This
+ trap is repeated periodically while the branchLoadStatus
+ remains in an error state. If the branchLoadStatus returns
+ to a non-error state ('normal' or 'notOn'), this trap is
+ sent once more with the non-error branchLoadStatus, and then
+ stops being repeated."
+ --#TYPE "Sentry: Branch Load Event."
+ --#SUMMARY "Load Status of Branch '%s' (%s) is '%s'."
+ --#ARGUMENTS { 2, 1, 6 }
+ --#SEVERITY CRITICAL
+ --#GENERIC 6
+ --#CATEGORY "Error Events"
+ --#SOURCE_ID "A"
+ --#TIMEINDEX 255
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE UNKNOWN
+ ::= { events 15 }
+
+END
|