+-- SIAE MICROELETTRONICA s.p.a.
+--
+-- Via Michelangelo Buonarroti, 21
+-- 20093 - Cologno Monzese
+-- Milano
+-- ITALY
+--
+-- ----------------------------------------------------------------------------
+-- ----------------------------------------------------------------------------
+
+SIAE-PTP-MIB
+ DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32
+ FROM SNMPv2-SMI
+ DisplayString, RowStatus, TruthValue, TEXTUAL-CONVENTION
+ FROM SNMPv2-TC
+ InterfaceIndex
+ FROM IF-MIB
+ siaeMib
+ FROM SIAE-TREE-MIB
+ AlarmStatus, AlarmSeverityCode
+ FROM SIAE-ALARM-MIB;
+
+ ptp MODULE-IDENTITY
+ LAST-UPDATED "201605050000Z"
+ ORGANIZATION "SIAE MICROELETTRONICA spa"
+ CONTACT-INFO
+ "SIAE MICROELETTONICA s.p.a.
+ Via Michelangelo Buonarroti, 21
+ 20093 - Cologno Monzese
+ Milano - ITALY
+ Phone : +39-02-27325-1
+ E-mail: help@siaemic.com
+ "
+ DESCRIPTION
+ "SIAE's Precision Time Protocol MIB.
+ For details see:
+ [1] IEEE Std 1588(TM)-2008, Standard for a Precision Clock
+ Synchronization Protocol for Networked Measurement and
+ Control Systems, 2008.
+ [2] Recommendation ITU-T G.8275.1/Y1369.1, Precision time protocol
+ telecom profile for phase/time synchronization with full timing
+ support from the network, draft 4 Apr 2014 . "
+ ::= { siaeMib 100 }
+
+--
+-- Textual Conventions for PTP
+--
+
+ ClockDomainType ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "The Domain is identified by an integer, the domainNumber, in
+ the range of 0 to 255. An integer value that is used to assign
+ each PTP device to a particular domain. The following values
+ define the valid domains. [1] Section 7.1 Domains Table 2
+
+ Value definition.
+ --------- -------------------
+ 0 Default domain
+ 1 Alternate domain 1
+ 2 Alternate domain 2
+ 3 Alternate domain 3
+ 4 - 23 User-defined domains
+ 24 - 43 Telecom Profile domains
+ 44 - 127 User-defined domains
+ 128 - 255 Reserved"
+
+ REFERENCE "Section 7.1 Domains and Table 2 of [1]"
+ SYNTAX Unsigned32 (24..43)
+
+ ClockProfileType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Clock Profile used. A profile is the set of allowed Precision
+ Time Protocol (PTP) features applicable to a device."
+
+ REFERENCE "Section 3.1.30 and 19.3 PTP profiles of
+ [IEEE 1588-2008]"
+ SYNTAX INTEGER {
+ default(1),
+ telecom(2),
+ vendorspecific(3)
+ }
+
+ ClockQualityAccuracyType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The ClockQuality as specified in section 5.3.7, 7.6.2.5 and
+ Table 6 of [1].
+
+ The following values are not represented in the enumerated
+ values.
+
+ 0x01-0x1F Reserved
+ 0x32-0x7F Reserved
+
+ It is important to note that section 7.1.1 RFC2578 allows for
+ gaps and enumerate values to start with zero when indicated by
+ the protocol."
+
+ REFERENCE "Section 5.3.7, 7.6.2.5 and Table 6 of [1]"
+ SYNTAX INTEGER {
+ reserved00(1), -- 0
+ nanoSecond25(32), -- 0x20
+ nanoSecond100(33), -- 0x21
+ nanoSecond250(34), -- 0x22
+ microSec1(35), -- 0x23
+ microSec2dot5(36), -- 0x24
+ microSec10(37), -- 0x25
+ microSec25(38), -- 0x26
+ microSec100(39), -- 0x27
+ microSec250(40), -- 0x28
+ milliSec1(41), -- 0x29
+ milliSec2dot5(42), -- 0x2A
+ milliSec10(43), -- 0x2B
+ milliSec25(44), -- 0x2C
+ milliSec100(45), -- 0x2D
+ milliSec250(46), -- 0x2E
+ second1(47), -- 0x2F
+ second10(48), -- 0x30
+ secondGreater10(49), -- 0x31
+ unknown(254), -- 0xFE
+ reserved255(255) -- 0xFF
+ }
+
+ ClockQualityClassType ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "The ClockQuality as specified in section 5.3.7, 7.6.2.4 and
+ Table 5 of [1].
+
+ Value Description
+ ------
+ ----------------------------------------------------------
+ 0 Reserved to enable compatibility with future
+ versions.
+ 1-5 Reserved
+ 6 Shall designate a clock that is synchronized
+ to a primary reference time source. The
+ timescale distributed shall be PTP. A
+ clockClass 6 clock shall not be a slave to
+ another clock in the domain.
+ 7 Shall designate a clock that has previously
+ been designated as clockClass 6 but that has
+ lost the ability to synchronize to a primary
+ reference time source and is in holdover mode
+ and within holdover specifications. The
+ timescale distributed shall be PTP. A
+ clockClass 7 clock shall not be a slave to
+ another clock in the domain.
+ 8 Reserved.
+ 9-10 Reserved to enable compatibility with future
+ versions.
+ 11-12 Reserved.
+ 13 Shall designate a clock that is synchronized
+ to an application-specific source of time.
+ The timescale distributed shall be ARB. A
+ clockClass 13 clock shall not be a slave to
+ another clock in the domain.
+ 14 Shall designate a clock that has previously
+ been designated as clockClass 13 but that
+ has lost the ability to synchronize to an
+ application-specific source of time and is
+ in holdover mode and within holdover
+ specifications. The timescale distributed
+ shall be ARB. A clockClass 14 clock shall
+ not be a slave to another clock in the domain.
+ 15-51 Reserved.
+ 52 Degradation alternative A for a clock of
+ clockClass 7 that is not within holdover
+ specification. A clock of clockClass 52
+ shall not be a slave to another clock in
+ the domain.
+ 53-57 Reserved.
+ 58 Degradation alternative A for a clock of
+ clockClass 14 that is not within holdover
+ specification. A clock of clockClass 58 shall
+ not be a slave to another clock in the domain.
+ 59-67 Reserved.
+ 68-122 For use by alternate PTP profiles.
+ 123-127 Reserved.
+ 128-132 Reserved.
+ 133-170 For use by alternate PTP profiles.
+ 171-186 Reserved.
+
+ 187 Degradation alternative B for a clock of
+ clockClass 7 that is not within holdover
+ specification. A clock of clockClass 187 may
+ be a slave to another clock in the domain.
+ 188-192 Reserved.
+ 193 Degradation alternative B for a clock of
+ clockClass 14 that is not within holdover
+ specification. A clock of clockClass 193 may
+ be a slave to another clock in the domain.
+ 194-215 Reserved.
+ 216-232 For use by alternate PTP profiles.
+ 233-247 Reserved.
+ 248 Default. This clockClass shall be used if
+ none of the other clockClass definitions apply.
+ 249-250 Reserved.
+ 251 Reserved for version 1 compatibility; see Clause 18.
+ 252-254 Reserved.
+ 255 Shall be the clockClass of a slave-only clock; see
+ 9.2.2.
+
+ The ClockQuality as specified in section 6.4 and
+ Table 2 of [2].
+
+ Value Description
+ ------
+ ----------------------------------------------------------
+ 6 T-GM connected to a PRTC in locked mode
+ (e.g. PRTC traceable to GNSS)
+ 140 T-GM in holdover, out of holdover specification,
+ traceable to Category 1 frequency source
+ 150 T-GM in holdover, out of holdover specification,
+ traceable to Category 2 frequency source
+ 160 T-GM in holdover, out of holdover specification,
+ traceable to Category 3 frequency source
+ 165 T-BC in holdover, out of holdover specification,
+ using unspecified frequency source
+ 255 Slave only OC (does not send Announce messages)
+
+ "
+
+ REFERENCE "section 5.3.7, 7.6.2.4 and Table 5 of [1].
+ section 6.4 and Table 2 of [2]"
+ SYNTAX INTEGER (0..255)
+
+ ClockStateType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The clock state returned by PTP engine.
+
+ Clock State Value Description
+ --------------------------------------------------------------
+ Freerun state 1 The PTP clock has never been synchronized
+ to a time source and is not in the process
+ of synchronizing to a time source.
+ As it relates to the PTP port state defined
+ in [IEEE 1588], a clock is in Free-Run state
+ if there are no PTP ports in: MASTER,
+ PRE-MASTER, PASSIVE, UNCALIBRATED,
+ or SLAVE states.
+
+ Acquiring state 2 The PTP clock is in process of synchronizing
+ to a time source. The duration and functionality
+ of this state is implementation specific. This
+ state is not required in an implementation.
+ As it relates to the PTP port state defined in
+ [IEEE 1588], a clock is in Acquiring state if
+ there is a PTP port in UNCALIBRATED state.
+
+ Locked state 3 The PTP clock is synchronized to a time source
+ and is within some internal acceptable accuracy.
+ As it relates to the PTP port state defined in
+ [IEEE 1588], a clock is in Locked state if there
+ is a PTP port in SLAVE state.
+
+ HoldoverInSpec state 4 The PTP clock is no longer synchronized to a
+ time source and is using information obtained
+ while it was previously synchronized or other
+ information sources were still available, to
+ maintain performance within desired specification.
+ The node may be relying solely on its own
+ facilities for holdover or may use something
+ like a frequency input from the network to
+ achieve a holdover of time and/or phase.
+ As it relates to the PTP port state defined in
+ [IEEE 1588], a clock is in HoldoverInSpec
+ state if there are no PTP ports in: INITIALIZING,
+ LISTENING, UNCALIBRATED or SLAVE states, and
+ performance is within desired specification.
+
+ HoldoverOutOfSpec state 5 The PTP clock is no longer synchronized to a time
+ source and, while it may be using information
+ obtained while it was previously synchronized or
+ other information sources were still available,
+ it is unable to maintain performance within
+ desired specification.
+ As it relates to the PTP port state defined in
+ [IEEE 1588], a clock is in HoldoverOutOfSpec
+ state if there are no PTP ports in: INITIALIZING,
+ LISTENING, UNCALIBRATED or SLAVE states, and
+ performance is not within desired specification."
+ SYNTAX INTEGER {
+ freerun(1),
+ acquiring(2),
+ locked(3),
+ holdoverInSpec(4),
+ holdoverOutOfSpec(5)
+ }
+
+ ClockTimeSourceType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The ClockQuality as specified in section 5.3.7, 7.6.2.6 and
+ Table 7 of [1].
+
+ The following values are not represented in the enumerated
+ values.
+
+ 0xF0-0xFE For use by alternate PTP profiles
+ 0xFF Reserved
+
+ It is important to note that section 7.1.1 RFC2578 allows for
+ gaps and enumerate values to start with zero when indicated by
+ the protocol."
+
+ REFERENCE "section 5.3.7, 7.6.2.6 and Table 7 of [1]."
+ SYNTAX INTEGER {
+ atomicClock(16), -- 0x10
+ gps(32), -- 0x20
+ terrestrialRadio(48), -- 0x22
+ ptp(64), -- 0x40
+ ntp(80), -- 0x50
+ handSet(96), -- 0x60
+ other(144), -- 0x90
+ internalOscillator(160), -- 0xA0
+ reserved(255) --0xFF
+ }
+
+ ClockInstanceType ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "The instance of the Clock of a given clock type in a given
+ domain."
+ SYNTAX Unsigned32 (0..255)
+
+
+ ClockPPSInstanceType ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "The instance of the PPS (and ToD) socket."
+ SYNTAX Unsigned32 (0..255)
+
+
+ ClockPortNumber ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "d"
+ STATUS current
+ DESCRIPTION
+ "An index identifying a specific Precision Time Protocol (PTP)
+ port on a PTP node."
+ REFERENCE "Section 7.5.2.3 Port Number and 5.3.5 of [1]"
+ SYNTAX Unsigned32 (0..65535)
+
+
+ ClockPortState ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "This is the value of the current state of the protocol engine
+ associated with this port.
+ Port state Value Description
+ -----------------------------------------------------------
+ initializing 1 In this state a port initializes
+ its data sets, hardware, and
+ communication facilities.
+ faulty 2 The fault state of the protocol.
+ disabled 3 The port shall not place any
+ messages on its communication path.
+ listening 4 The port is waiting for the
+ announceReceiptTimeout to expire or
+ to receive an Announce message from
+ a master.
+ preMaster 5 The port shall behave in all respects
+ as though it were in the MASTER state
+ except that it shall not place any
+ messages on its communication path
+ except for Pdelay_Req, Pdelay_Resp,
+ Pdelay_Resp_Follow_Up, signaling, or
+ management messages.
+ master 6 The port is behaving as a master
+ port.
+ passive 7 The port shall not place any
+ messages on its communication path
+ except for Pdelay_Req, Pdelay_Resp,
+ Pdelay_Resp_Follow_Up, or signaling
+ messages, or management messages
+ that are a required response to
+ another management message
+ uncalibrated 8 The local port is preparing to
+ synchronize to the master port.
+ slave 9 The port is synchronizing to the
+ selected master port."
+
+ REFERENCE "Section 8.2.5.3.1 portState and 9.2.5 of [1]"
+ SYNTAX INTEGER {
+ initializing(1),
+ faulty(2),
+ disabled(3),
+ listening(4),
+ preMaster(5),
+ master(6),
+ passive(7),
+ uncalibrated(8),
+ slave(9)
+ }
+
+ ClockMechanismType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The clock type based on whether End to End or peer to peer
+ mechanisms are used. The mechanism used to calculate the Mean
+ Path Delay as indicated in Table 9 of IEEE 1588-2008.
+
+ Delay mechanism Value(hex) Specification
+ E2E 01 The port is configured to use
+ the delay request-response
+ mechanism.
+
+ P2P 02 The port is configured to use
+ the peer delay mechanism.
+
+ DISABLED FE The port does not implement
+ the delay mechanism."
+
+ REFERENCE "Sections 8.2.5.4.4, 6.6.4 and 7.4.2 of [1]."
+ SYNTAX INTEGER {
+ e2e(1)
+ -- p2p(2),
+ -- disabled(254)
+ }
+
+ ClockTimeInterval ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "This textual convention corresponds to the TimeInterval
+ structure indicated in section 5.3.2 of [1]. It will be
+ presented in the form of a character array.
+
+ The TimeInterval type represents time intervals.
+
+ struct TimeInterval
+ {
+ Integer64 scaledNanoseconds;
+ };
+
+ The scaledNanoseconds member is the time interval expressed in
+ units of nanoseconds and multiplied by 2**16.
+
+ Positive or negative time intervals outside the maximum range
+ of this data type shall be encoded as the largest positive and
+ negative values of the data type, respectively.
+
+ For example, 2.5 ns is expressed as 0000 0000 0002 8000 in
+ Base16."
+
+ REFERENCE
+ "Section 5.3.2 and setion 7.7.2.1 Timer interval
+ specification of [1]"
+ SYNTAX OCTET STRING (SIZE (1..255))
+
+ ClockType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The clock types as defined in the MIB module description."
+
+ REFERENCE "section 6.5.1 of [1]."
+ SYNTAX INTEGER {
+ --ordinaryClock(1),
+ boundaryClock(2)
+ --transparentClock(3),
+ --boundaryNode(4)
+ }
+
+ PtpClockToDFormatType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "This is the format used for ToD signal in input or in output direcdtion.
+
+ -----------------------------------------------------------
+ Format Value Description
+ -----------------------------------------------------------
+ telecomTimeEvent 1
+ telecomTimeAnnounce 2
+ telecomGNSSstatus 3
+ NMEAzda 4 ASCII format (eg: $GPZDA,003157.00,01,01,1970,00,00*69)
+ ISO8601 5 ASCII format (eg: 1970-01-01T00:32:47Z)
+ NTP 6 ASCII format (eg: 70 001 00:30:51.000 S)
+ Ublox 7 Not ASCII
+ ChinaMobile 8 Not ASCII
+ ChinaTelecom 9 Not ASCII (standard ITU G.8271 is derived from this)
+ BCM 10 Not ASCII
+ BCMTS 11 Not ASCII
+ -----------------------------------------------------------"
+ SYNTAX INTEGER {
+ telecomTimeEvent(1),
+ telecomTimeAnnounce(2),
+ telecomGNSSstatus(3),
+ nmeazda(4),
+ iso8601(5),
+ ntp(6),
+ ublox(7),
+ chinaMobile(8),
+ chinaTelecom(9),
+ bcm(10),
+ bcmts(11)
+ }
+
+--------------------------------------------------------------------------------
+-- PTP GROUP
+--------------------------------------------------------------------------------
+--
+-- This group is used for Precision Time Protocol version 2 configuration and alarm reporting
+--
+-- For details see:
+-- [1] IEEE Std 1588(TM)-2008, Standard for a Precision Clock
+-- Synchronization Protocol for Networked Measurement and
+-- Control Systems, 2008.
+-- [2] Recommendation ITU-T G.8275.1/Y1369.1, Precision time protocol
+-- telecom profile for phase/time synchronization with full timing
+-- support from the network, draft 4 Apr 2014 .
+--
+--------------------------------------------------------------------------------
+
+------ Beginning --------------------------------------------------------------
+
+ ptpMibVersion OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Numerical version of this module.
+ The string version of this MIB have the following format:
+ XX.YY.ZZ
+ so, for example, the value 1 should be interpreted as 00.00.01
+ and the value 10001 should be interpreted as 01.00.01."
+ DEFVAL {1}
+ ::= { ptp 1 }
+
+
+ ptpProfileDataSet OBJECT IDENTIFIER ::= { ptp 2 }
+ ptpSpecificDataSet OBJECT IDENTIFIER ::= { ptp 3 }
+ ptpDefaultDataSet OBJECT IDENTIFIER ::= { ptp 4 }
+ ptpCurrentDataSet OBJECT IDENTIFIER ::= { ptp 5 }
+ ptpParentDataSet OBJECT IDENTIFIER ::= { ptp 6 }
+ ptpTimePropertiesDataSet OBJECT IDENTIFIER ::= { ptp 7 }
+ ptpPortDataSet OBJECT IDENTIFIER ::= { ptp 8 }
+ ptpClockPPSDataSet OBJECT IDENTIFIER ::= { ptp 9 }
+ ptpRadioAsymmetryDataSet OBJECT IDENTIFIER ::= { ptp 10 }
+
+------- Begin of Ptp Profile data set.
+--
+
+ ptpSystemProfile OBJECT-TYPE
+ SYNTAX ClockProfileType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the PTP Profile implemented on the
+ system."
+ REFERENCE "Section 19.3 PTP profiles of [1]"
+ ::= { ptpProfileDataSet 1 }
+
+ ptpProfileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..128))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object describes the PTP Profile implemented on the system."
+ REFERENCE "Section 19.3 PTP profiles of [1]"
+-- DEFVAL { "ITU-T PTP profile for phase/time distribution with full timing support from the network" }
+ ::= { ptpProfileDataSet 2 }
+
+ ptpProfilePrimaryVersion OBJECT-TYPE
+ SYNTAX Integer32(0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The version of the profile consist of two fields: a primaryVersion
+ and a revisionNumber. The profileVersion shall be printed as
+ primaryVersion.revisionNumber
+ "
+ REFERENCE "Section 19.3 PTP profiles of [1]"
+ DEFVAL { 1 }
+ ::= { ptpProfileDataSet 3 }
+
+ ptpProfileRevisionNumber OBJECT-TYPE
+ SYNTAX Integer32(0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The version of the profile consist of two fields: a primaryVersion
+ and a revisionNumber. The profileVersion shall be printed as
+ primaryVersion.revisionNumber
+ "
+ REFERENCE "Section 19.3 PTP profiles of [1]"
+ DEFVAL { 0 }
+ ::= { ptpProfileDataSet 4 }
+
+ ptpProfileIdentifier OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(6))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object show the PTP Profile version on the system."
+ REFERENCE "Section 19.3 PTP profiles of [1]"
+ DEFVAL {'0019A7010100'h}
+ ::= { ptpProfileDataSet 5 }
+
+--
+------- End of Ptp Profile data set.
+
+
+
+
+------- Begin of Ptp Default data set.
+-- Characterizes the PTP clock of the system.
+--
+
+ ptpClockDataSetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PtpClockDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of information about the PTP clock Default Datasets for
+ all domains."
+ ::= { ptpDefaultDataSet 1 }
+
+ ptpClockDataSetEntry OBJECT-TYPE
+ SYNTAX PtpClockDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Contains the information of the clock on a particular doamin. This
+ table will be initialised with default values if the clock is
+ operating as a boundary or ordinary clock in the domain."
+ INDEX { ptpClockDomainIndex,
+ ptpClockTypeIndex,
+ ptpClockInstanceIndex }
+ ::= { ptpClockDataSetTable 1 }
+
+ PtpClockDataSetEntry ::= SEQUENCE {
+ ptpClockDomainIndex ClockDomainType,
+ ptpClockTypeIndex ClockType,
+ ptpClockInstanceIndex ClockInstanceType,
+ ptpClockIdentity OCTET STRING,
+ ptpClockTwoStepFlag TruthValue,
+ ptpClockNumberPorts Integer32,
+ ptpClockClass ClockQualityClassType,
+ ptpClockAccuracy ClockQualityAccuracyType,
+ ptpClockOffsetScaledLogVariance Integer32,
+ ptpClockPriority1 Integer32,
+ ptpClockPriority2 Integer32,
+ ptpClockSlaveOnly TruthValue,
+ ptpClockLocalPriority INTEGER,
+ ptpClockRowStatus RowStatus
+ }
+
+ ptpClockDomainIndex OBJECT-TYPE
+ SYNTAX ClockDomainType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the domain number used to create logical
+ group of PTP devices. The Clock Domain is a logical group of
+ clocks and devices that synchronize with each other using the
+ PTP protocol."
+ ::= { ptpClockDataSetEntry 1 }
+
+ ptpClockTypeIndex OBJECT-TYPE
+ SYNTAX ClockType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the clock type as defined in the
+ Textual convention description."
+ ::= { ptpClockDataSetEntry 2 }
+
+ ptpClockInstanceIndex OBJECT-TYPE
+ SYNTAX ClockInstanceType (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the instance of the Clock for this clock
+ type for the given domain."
+ ::= { ptpClockDataSetEntry 3 }
+
+ ptpClockIdentity OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the unique identity of the local clock or management node.
+ This should be the smptpDomainClockIdentity of the domain indicated
+ by the ptpDomainNumber. Configuration of this value will take effect
+ only when the PTP module is enabled."
+ ::= {ptpClockDataSetEntry 4 }
+
+ ptpClockTwoStepFlag OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This value is TRUE if the clock is two step clock, otherwise it is
+ FALSE. If this value is configured as TRUE, then PTP will transmit the
+ originTimeStamp only through follow-up messages."
+ DEFVAL { false }
+ ::= { ptpClockDataSetEntry 5 }
+
+ ptpClockNumberPorts OBJECT-TYPE
+ SYNTAX Integer32 (1..128)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This indicates the number of PTP ports on the device. For an ordinary
+ clock this value should be 1."
+ DEFVAL { 6 }
+ ::= { ptpClockDataSetEntry 6 }
+
+ ptpClockClass OBJECT-TYPE
+ SYNTAX ClockQualityClassType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the default dataset Quality Class."
+ DEFVAL { 248 }
+ ::= { ptpClockDataSetEntry 7 }
+
+ ptpClockAccuracy OBJECT-TYPE
+ SYNTAX ClockQualityAccuracyType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the default dataset Quality Accurarcy."
+ DEFVAL { unknown }
+ ::= { ptpClockDataSetEntry 8 }
+
+ ptpClockOffsetScaledLogVariance OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This value is an estimate of the variations of the local clock
+ from a linear timescale when it is not synchronized to another
+ clock using the protocol. The initialization value depends on the
+ inherent characteristics of the clock during initialization. This
+ value is used by the BMC algorithm to select the best master clock"
+ DEFVAL { 0 }
+ ::= { ptpClockDataSetEntry 9 }
+
+ ptpClockPriority1 OBJECT-TYPE
+ SYNTAX Integer32 (128)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This value is used by BMC algorithm to select the best master
+ clock. Lower values take precedence."
+ DEFVAL { 128 }
+ ::= { ptpClockDataSetEntry 10 }
+
+ ptpClockPriority2 OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This value is used by BMC algorithm to select the best master clock.
+ This is used as a tiebreaker when the BMC failes to order the clock
+ using ptpClockPriority1, ptpClockClass, ptpClockAccuracy and
+ ptpClockOffsetScaledLogVariance.
+ Lower values take precedence"
+ DEFVAL { 128 }
+ ::= { ptpClockDataSetEntry 11 }
+
+ ptpClockSlaveOnly OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Configuring this value as true will make the clock to behave as slave
+ clock.
+ A boundary clock can not be a slave only clock."
+ DEFVAL { false }
+ ::= { ptpClockDataSetEntry 12 }
+
+ ptpClockLocalPriority OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This attribute is used in the alternate BMCA as a tie-breaker in the
+ dataset comparison algorithm, in the event that all other previous
+ attributes of the datasets being compared are equal."
+ REFERENCE "Section 6.3.1 and 6.3.2 of [2]"
+ DEFVAL { 128 }
+ ::= { ptpClockDataSetEntry 13 }
+
+ ptpClockRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "RowStatus for creating the entries into this table.
+ This object support only destroy and createAndGo values."
+ ::= { ptpClockDataSetEntry 14 }
+
+
+--
+------- End of Ptp Default data set.
+
+
+------- Begin of Ptp Specific data set
+-- Contains global configuration/information
+-- of a particular PTP clock.
+--
+
+ ptpSpecificDataSetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PtpSpecificDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of vendor specific information about the PTP clock
+ for all domains."
+ ::= { ptpSpecificDataSet 1 }
+
+ ptpSpecificDataSetEntry OBJECT-TYPE
+ SYNTAX PtpSpecificDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Contains vendor specific information for a particular PTP clock.
+ Where not otherwise specified, every object of this entry can
+ be modified with the conceptual row active."
+ INDEX { ptpClockDomainIndex,
+ ptpClockTypeIndex,
+ ptpClockInstanceIndex
+ }
+ ::= { ptpSpecificDataSetTable 1 }
+
+ PtpSpecificDataSetEntry ::= SEQUENCE {
+ ptpAdminStatus INTEGER,
+ ptpStaticPortRole TruthValue,
+ ptpClockState ClockStateType,
+ ptpCompliance INTEGER
+ }
+
+ ptpAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ down (1),
+ up (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object states if PTP is enabled or disabled for this PTP Clock
+ in order to switch on/off the PTP protocol."
+ DEFVAL { down }
+ ::= { ptpSpecificDataSetEntry 1 }
+
+ ptpStaticPortRole OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object states that in the PTP Clock the A-BMCA is disabled and
+ it is working in Static PTP Port Role mode."
+ DEFVAL { false }
+ ::= { ptpSpecificDataSetEntry 2 }
+
+ ptpClockState OBJECT-TYPE
+ SYNTAX ClockStateType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object shows the current state of the PTP Clock State Machine"
+ ::= { ptpSpecificDataSetEntry 3 }
+
+ ptpCompliance OBJECT-TYPE
+ SYNTAX INTEGER {
+ strictCompatibility (1),
+ looseCompatibility (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object states if the clock is strictly profile compliant. The
+ meaning of looseCompatibility is application dependent."
+ DEFVAL { looseCompatibility }
+ ::= { ptpSpecificDataSetEntry 4 }
+
+ --
+ -- Ptp Specific alarms. Contains alarms of a particular PTP clock
+ -- .
+
+ ptpSpecificAlarmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PtpSpecificAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of vendor specific information about the PTP clock
+ for all domains."
+ ::= { ptpSpecificDataSet 2 }
+
+ ptpSpecificAlarmEntry OBJECT-TYPE
+ SYNTAX PtpSpecificAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Contains vendor specific alarm information for a particular PTP clock."
+ INDEX { ptpClockDomainIndex,
+ ptpClockTypeIndex,
+ ptpClockInstanceIndex
+ }
+ ::= { ptpSpecificAlarmTable 1 }
+
+ PtpSpecificAlarmEntry ::= SEQUENCE {
+ ptpFreeRunningAlarm AlarmStatus,
+ ptpHoldoverInSpecAlarm AlarmStatus,
+ ptpHoldoverOutOfSpecAlarm AlarmStatus
+ }
+
+ ptpFreeRunningAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This alarm is raised when ptpClockState is set to freerun(1).
+ "
+ ::= { ptpSpecificAlarmEntry 1 }
+
+ ptpHoldoverInSpecAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This alarm is raised when ptpClockState is set to
+ holdoverInSpec(4).
+ "
+ ::= { ptpSpecificAlarmEntry 2 }
+
+ ptpHoldoverOutOfSpecAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This alarm is raised when ptpClockState is set to
+ holdoverOutOfSpec(5).
+ "
+ ::= { ptpSpecificAlarmEntry 3 }
+
+ --
+ -- Ptp specific alarm severities.
+ --
+
+ ptpFreeRunningAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object defines the severity associated to
+ ptpFreeRunningAlarm and enables or disables the
+ sending of the SNMP Trap on the alarm status transition.
+ "
+ DEFVAL { warningTrapEnable }
+ ::= { ptpSpecificDataSet 3 }
+
+ ptpHoldoverInSpecAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object defines the severity associated to
+ ptpHoldoverInSpecAlarm and enables or disables the
+ sending of the SNMP Trap on the alarm status transition.
+ "
+ DEFVAL { warningTrapEnable }
+ ::= { ptpSpecificDataSet 4 }
+
+ ptpHoldoverOutOfSpecAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object defines the severity associated to
+ ptpHoldoverOutOfSpecAlarm and enables or disables the
+ sending of the SNMP Trap on the alarm status transition.
+ "
+ DEFVAL { majorTrapEnable }
+ ::= { ptpSpecificDataSet 5 }
+
+--
+------- End of Ptp Specific data set.
+
+
+------- Begin of Ptp Current data set.
+-- Synchronization information of the PTP clock.
+--
+
+ ptpCurrentDataSetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PtpCurrentDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of information about the PTP clock Current Datasets for
+ all domains."
+ ::= { ptpCurrentDataSet 1 }
+
+ ptpCurrentDataSetEntry OBJECT-TYPE
+ SYNTAX PtpCurrentDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ " Contains synchronization information on a particular domain."
+ INDEX { ptpClockDomainIndex,
+ ptpClockTypeIndex,
+ ptpClockInstanceIndex }
+ ::= { ptpCurrentDataSetTable 1 }
+
+ PtpCurrentDataSetEntry ::= SEQUENCE {
+ ptpCurrentStepsRemoved Integer32,
+ ptpCurrentOffsetFromMaster ClockTimeInterval,
+ ptpCurrentMeanPathDelay ClockTimeInterval
+ }
+
+ ptpCurrentStepsRemoved OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the distance measured by the number of
+ Boundary clocks between the local clock and the Foreign master
+ as indicated in the stepsRemoved field of Announce messages.
+ Slave clock will update this field once port is selected as slave."
+ REFERENCE "1588 Version 2.0 Section 8.2.2.2 stepsRemoved"
+ ::= { ptpCurrentDataSetEntry 1 }
+
+ ptpCurrentOffsetFromMaster OBJECT-TYPE
+ SYNTAX ClockTimeInterval
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the current clock dataset ClockOffset
+ value. The value of the computation of the offset in time
+ between a slave and a master clock."
+ REFERENCE "1588 Version 2.0 Section 8.2.2.3 of [1]"
+ ::= { ptpCurrentDataSetEntry 2 }
+
+ ptpCurrentMeanPathDelay OBJECT-TYPE
+ SYNTAX ClockTimeInterval
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the current clock dataset
+ MeanPathDelay value.
+ The mean path delay between a pair of ports as measure by the
+ delay request-response mechanism."
+ REFERENCE "1588 Version 2.0 Section 8.2.2.4 mean path delay"
+ ::= { ptpCurrentDataSetEntry 3 }
+
+--
+------- End of Ptp Current data set.
+
+
+
+------- Begin of Ptp Parent data set.
+-- Information about parent PTP clock.
+--
+
+ ptpParentDataSetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PtpParentDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of information about the PTP clock Parent Datasets for
+ all domains."
+ ::= { ptpParentDataSet 1 }
+
+ ptpParentDataSetEntry OBJECT-TYPE
+ SYNTAX PtpParentDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Contains parent clock information on a particular domain. "
+ INDEX { ptpClockDomainIndex,
+ ptpClockTypeIndex,
+ ptpClockInstanceIndex }
+ ::= { ptpParentDataSetTable 1 }
+
+ PtpParentDataSetEntry ::= SEQUENCE {
+ ptpParentClockIdentity OCTET STRING,
+ ptpParentPortNumber ClockPortNumber,
+ ptpParentGMClockIdentity OCTET STRING,
+ ptpParentGMClockClass ClockQualityClassType,
+ ptpParentGMClockAccuracy ClockQualityAccuracyType,
+ ptpParentGMClockOffsetScaledLogVariance Integer32,
+ ptpParentGMPriority1 Integer32,
+ ptpParentGMPriority2 Integer32
+ }
+
+ ptpParentClockIdentity OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the clock identity of the port on the master that issues
+ sync messages used in synchronizing this clock. The initial value
+ of this field is the value of ptpClockIdentity"
+ REFERENCE "section 8.2.3.2 parentDS.parentPortIdentity of [1]"
+ ::= { ptpParentDataSetEntry 1 }
+
+ ptpParentPortNumber OBJECT-TYPE
+ SYNTAX ClockPortNumber
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the port number identity of the port on the master that issues
+ sync message used in synchronizing this clock. Combination of
+ ptpParentClockIdentity and ptpParentPortNumber gives the port identity
+ of the parent clock."
+ REFERENCE "section 8.2.3.2 parentDS.parentPortIdentity of [1]"
+ ::= { ptpParentDataSetEntry 2 }
+
+ ptpParentGMClockIdentity OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the clock identity attribute of the grand master clock.
+ The initial value is ptpClockIdentity."
+ REFERENCE "section 8.2.3.6 parentDS.grandmasterIdentity of [1]"
+ ::= { ptpParentDataSetEntry 3 }
+
+ ptpParentGMClockClass OBJECT-TYPE
+ SYNTAX ClockQualityClassType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the clock class of the grandmaster. The
+ initialization value of this variable is ptpClockClass."
+ REFERENCE "section 8.2.3.7 parentDS.grandmasterClockQuality of [1]"
+ ::= { ptpParentDataSetEntry 4 }
+
+ ptpParentGMClockAccuracy OBJECT-TYPE
+ SYNTAX ClockQualityAccuracyType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the clock accuracy of the grandmaster. The
+ initialization value of this variable is ptpClockAccuracy"
+ REFERENCE "section 8.2.3.7 parentDS.grandmasterClockQuality of [1]"
+ ::= { ptpParentDataSetEntry 5 }
+
+ ptpParentGMClockOffsetScaledLogVariance OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the offset scaled log variance of the grandmaster. The
+ initialization value of this variable is
+ ptpClockOffsetScaledLogVariance"
+ REFERENCE "section 8.2.3.7 parentDS.grandmasterClockQuality of [1]"
+ ::= { ptpParentDataSetEntry 6 }
+
+ ptpParentGMPriority1 OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the priority1 of the grandmaster clock. The
+ initialization value of this variable is ptpClockPriority1"
+ REFERENCE "section 8.2.3.8 parentDS.grandmasterPriority1 of [1]"
+ ::= { ptpParentDataSetEntry 7 }
+
+ ptpParentGMPriority2 OBJECT-TYPE
+ SYNTAX Integer32 (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the priority2 of the grandmaster clock. The
+ initialization value of this variable is ptpClockPriority2"
+ REFERENCE "section 8.2.3.9 parentDS.grandmasterPriority2 of [1]"
+ ::= { ptpParentDataSetEntry 8 }
+
+--
+------- End of Ptp Parent data set.
+
+
+
+------- Begin of Ptp Time properties data set.
+-- Global time properties of the clock.
+--
+
+ ptpTimeDataSetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PtpTimeDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of information about the PTP clock Timeproperties
+ Datasets for all domains."
+ ::= { ptpTimePropertiesDataSet 1 }
+
+ ptpTimeDataSetEntry OBJECT-TYPE
+ SYNTAX PtpTimeDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Contains parent Time properties information of the
+ clock on a particular domain."
+ INDEX { ptpClockDomainIndex,
+ ptpClockTypeIndex,
+ ptpClockInstanceIndex }
+ ::= { ptpTimeDataSetTable 1 }
+
+ PtpTimeDataSetEntry ::= SEQUENCE {
+ ptpTimeCurrentUTCOffset Integer32,
+ ptpTimeCurrentUTCOffsetValid TruthValue,
+ ptpTimeLeap59 TruthValue,
+ ptpTimeLeap61 TruthValue,
+ ptpTimeTimeTraceable TruthValue,
+ ptpTimeFrequencyTraceable TruthValue,
+ ptpTimescale TruthValue,
+ ptpTimeTimeSource ClockTimeSourceType
+ }
+
+ ptpTimeCurrentUTCOffset OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If systems epoch is the PTP epoch then this value indicates the offset
+ in seconds between TAI and UTC."
+ REFERENCE "section 8.2.4.2 timePropertiesDS.currentUtcOffset of [1]"
+ ::= { ptpTimeDataSetEntry 1 }
+
+ ptpTimeCurrentUTCOffsetValid OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of this variable is TRUE if the ptpTimeCurrentUTCOffset is
+ known to be correct."
+ REFERENCE "section 8.2.4.3 timePropertiesDS.currentUtcOffsetValid of [1]"
+ ::= { ptpTimeDataSetEntry 2 }
+
+ ptpTimeLeap59 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If the systems epoch is PTP epoch then TRUE value of this variable
+ indicates that the last minute of the current UTC day contains 59
+ seconds."
+ REFERENCE "section 8.2.4.4 timePropertiesDS.leap59 of [1]"
+ ::= { ptpTimeDataSetEntry 3 }
+
+ ptpTimeLeap61 OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If the systems epoch is PTP epoch then TRUE value of this variable
+ indicates that the last minute of the current UTC day contains 61
+ seconds."
+ REFERENCE "section 8.2.4.5 timePropertiesDS.leap61 of [1]"
+ ::= { ptpTimeDataSetEntry 4 }
+
+ ptpTimeTimeTraceable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable is TRUE if the timescale and value of
+ ptpTimeCurrentUTCOffset are traceable to a primary reference
+ otherwise, the value shall be FALSE."
+ REFERENCE "section 8.2.4.6 timePropertiesDS.timeTraceable of [1]"
+ ::= { ptpTimeDataSetEntry 5 }
+
+ ptpTimeFrequencyTraceable OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable is TRUE if the frequecy determining the timescale is
+ traceable to a primary reference otherwise, the value shall be FALSE."
+ REFERENCE "section 8.2.4.7 timePropertiesDS.frequencyTraceable of [1]"
+ ::= { ptpTimeDataSetEntry 6 }
+
+ ptpTimescale OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable is TRUE if the clock timescale of the grandmaster clock
+ is PTP otherwise, the value shall be FALSE."
+ REFERENCE "section 8.2.4.8 timePropertiesDS.ptpTimescale of [1]"
+ ::= { ptpTimeDataSetEntry 7 }
+
+ ptpTimeTimeSource OBJECT-TYPE
+ SYNTAX ClockTimeSourceType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the source of time used by the grandmaster clock. If the time
+ source is known at the time of initialization then the value will be set
+ to that otherwise the initial value is INTERNAL_OSCILLATOR(160)."
+ REFERENCE "section 8.2.4.9 timePropertiesDS.timeSource of [1]"
+ DEFVAL { internalOscillator }
+ ::= { ptpTimeDataSetEntry 8 }
+
+--
+------- End of Ptp Time properties data set.
+
+------- Begin of Ptp PPS and ToD properties data set.
+--
+
+ ptpClockPPSDataSetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PtpClockPPSDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of information about the PTP clock PPS and ToD properties."
+ ::= { ptpClockPPSDataSet 1 }
+
+ ptpClockPPSDataSetEntry OBJECT-TYPE
+ SYNTAX PtpClockPPSDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Contains PPS and ToD properties information of the
+ specific domain and clock on a specific PPS socket."
+ INDEX { ptpClockDomainIndex,
+ ptpClockTypeIndex,
+ ptpClockInstanceIndex,
+ ptpClockPPSInstanceIndex }
+ ::= { ptpClockPPSDataSetTable 1 }
+
+ PtpClockPPSDataSetEntry ::= SEQUENCE {
+ ptpClockPPSInstanceIndex ClockPPSInstanceType,
+ ptpClockPPSInstanceCapability Unsigned32,
+ ptpClockPPSDirection INTEGER,
+
+ ptpClockPPSLabel DisplayString,
+ ptpClockPPSAdminStatus INTEGER,
+ ptpClockPPSOffsetEnabled TruthValue,
+ ptpClockPPSOffsetValue Integer32,
+
+ ptpClockToDLabel DisplayString,
+ ptpClockToDAdminStatus INTEGER,
+ ptpClockToDDelay Unsigned32,
+ ptpClockToDBaudrate Unsigned32,
+ ptpClockToDFormat PtpClockToDFormatType
+ }
+
+
+ ptpClockPPSInstanceIndex OBJECT-TYPE
+ SYNTAX ClockPPSInstanceType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the id of PPS interface socket.
+ It represents the id of ToD interface socket too."
+ DEFVAL { 0 }
+ ::= { ptpClockPPSDataSetEntry 1 }
+
+
+ ptpClockPPSInstanceCapability OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is a bitmap and each bit represents
+ a specific capability of the PPS or ToD interface.
+ Bit 0 : 1 = the interface can be used either in input or in output
+ and the user can select the direction using ptpClockPPSDirection object;
+ 0 = the interface can have one direction specified by the system,
+ in this case the ptpClockPPSDirection object is read only.
+ Bit 1 : 1 = the ToD interface allows more baudrate;
+ 0 = the ToD interface allows one only baudrate, fixed by system. "
+ DEFVAL { 0 }
+ ::= { ptpClockPPSDataSetEntry 2 }
+
+
+ ptpClockPPSDirection OBJECT-TYPE
+ SYNTAX INTEGER {
+ input (1),
+ output (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the direction (input or output)
+ of PPS signal and ToD data"
+ DEFVAL { 2 }
+ ::= { ptpClockPPSDataSetEntry 3 }
+
+
+ ptpClockPPSLabel OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the label as appears near the PPS signal socket"
+ DEFVAL { "PPS" }
+ ::= { ptpClockPPSDataSetEntry 4 }
+
+
+ ptpClockPPSAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ down (1),
+ up (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is the administrive status of PPS interface and
+ specifies whether the node is enabled for PTP input/output
+ clocking using the PPS interface."
+ DEFVAL { down }
+ ::= { ptpClockPPSDataSetEntry 5 }
+
+
+ ptpClockPPSOffsetEnabled OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies whether an offset is configured
+ in order to compensate for a known phase error
+ such as network asymmetry."
+ ::= { ptpClockPPSDataSetEntry 6 }
+
+
+ ptpClockPPSOffsetValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the fixed offset signed value in nanoseconds
+ configured to be added for the PPS output or input."
+ ::= { ptpClockPPSDataSetEntry 7 }
+
+
+ ptpClockToDLabel OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..16))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object specifies the label as appears near the ToD socket"
+ DEFVAL { "ToD" }
+ ::= { ptpClockPPSDataSetEntry 8 }
+
+
+ ptpClockToDAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER{
+ down (1),
+ up (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is the administrive status of PPS interface and
+ specifies whether the ToD interface is enabled."
+ DEFVAL { down }
+ ::= { ptpClockPPSDataSetEntry 9 }
+
+
+ ptpClockToDDelay OBJECT-TYPE
+ SYNTAX Unsigned32 (0..999999)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies microseconds of delay between PPS edge
+ and ToD data emitted, used only in output direction."
+ DEFVAL { 0 }
+ ::= { ptpClockPPSDataSetEntry 10 }
+
+
+ ptpClockToDBaudrate OBJECT-TYPE
+ SYNTAX Unsigned32 (300|600|1200|1800|2400|4800|9600|19200|38400|57600|115200|230400)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the Baudrate of ToD signal in input or output direction."
+ DEFVAL { 9600 }
+ ::= { ptpClockPPSDataSetEntry 11 }
+
+
+ ptpClockToDFormat OBJECT-TYPE
+ SYNTAX PtpClockToDFormatType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object specifies the format of ToD signal in input or output direction."
+ DEFVAL { telecomTimeEvent }
+ ::= { ptpClockPPSDataSetEntry 12 }
+
+--
+------- End of Ptp PPS and ToD properties data set.
+
+
+------- Begin of Ptp Port data set.
+-- Configuration information of a particular PTP port.
+--
+
+ ptpPortDataSetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PtpPortDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table Contains PTP configuration information
+ for a particular port of boundary or an ordinary clock"
+ ::= { ptpPortDataSet 1 }
+
+ ptpPortDataSetEntry OBJECT-TYPE
+ SYNTAX PtpPortDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Contains PTP configuration information for a particular port.
+ Valid ptpPortIfIndex need to be given to make this entry active.
+ Where not otherwise specified, every object of this entry
+ can be modified with the conceptual row active."
+ INDEX { ptpClockDomainIndex,
+ ptpClockTypeIndex,
+ ptpClockInstanceIndex,
+ ptpPortIndex
+ }
+ ::= { ptpPortDataSetTable 1 }
+
+ PtpPortDataSetEntry ::= SEQUENCE {
+ ptpPortIndex ClockPortNumber,
+ ptpPortClockIdentity OCTET STRING,
+ ptpPortIfIndex InterfaceIndex,
+ ptpPortStaticRole INTEGER,
+ ptpPortAdminStatus INTEGER,
+ ptpPortState ClockPortState,
+ ptpPortMinDelayReqInterval Integer32,
+ ptpPortLogAnnounceInterval Integer32,
+ ptpPortAnnounceReceiptTimeout Integer32,
+ ptpPortSyncInterval Integer32,
+ ptpPortDelayMechanism ClockMechanismType,
+ ptpPortVersionNumber Integer32,
+ ptpPortNotSlave TruthValue,
+ ptpPortLocalPriority Integer32,
+ ptpPortDestMacAddress INTEGER,
+ ptpPortTxAsymmetryCompensation Integer32,
+ ptpPortRxAsymmetryCompensation Integer32,
+ ptpPortRowStatus RowStatus
+ }
+
+ ptpPortIndex OBJECT-TYPE
+ SYNTAX ClockPortNumber
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The index value used to identify the port component on the device.
+ The value of this object is used as a port index to the
+ ptpPortConfigDataSetTable."
+ ::= { ptpPortDataSetEntry 1 }
+
+ ptpPortClockIdentity OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (8))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the clock Identity of the port"
+ REFERENCE "section 8.2.5.2.1 portDS.portIdentity of [1]"
+ ::= { ptpPortDataSetEntry 2 }
+
+ ptpPortIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndex
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This is the index in ifTable of this port.
+ This object can't be modified."
+ ::= { ptpPortDataSetEntry 3 }
+
+ ptpPortStaticRole OBJECT-TYPE
+ SYNTAX INTEGER {
+ master (6),
+ passive (7),
+ slave (9)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Role of this port. This object forces the role of the port if
+ ptpStaticPortRole is true."
+ DEFVAL { master }
+ ::= { ptpPortDataSetEntry 4}
+
+ ptpPortAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ down (1),
+ up (2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Administrive status of the port. The value down turns off the PTP
+ protocol on the ethernet port."
+ DEFVAL { down }
+ ::= { ptpPortDataSetEntry 5 }
+
+ ptpPortState OBJECT-TYPE
+ SYNTAX ClockPortState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This denotes the PTP State of the PTP port as computed by the PTP State
+ event machine.
+
+ initializing:
+ While a port is in the INITIALIZING state, the port initializes its data
+ sets, hardware, and communication facilities. No port of the clock shall
+ place any PTP messages on its communication path. If one port of a
+ boundary clock is in the INITIALIZING state, then all ports shall be in
+ the INITIALIZING state.
+
+ faulty:
+ The fault state of the protocol. A port in this state shall not place any
+ PTP messages except for management messages that are a required response
+ to another management message on its communication path.
+
+ disabled:
+ The port shall not place any messages on its communication path. In a
+ boundary clock, no activity at the port shall be allowed to affect the
+ activity at any other port of the boundary clock. A port in this state
+ shall discard all PTP received messages except for management messages.
+
+ listening:
+ The port is waiting for the announceReceiptTimeout to expire or to
+ receive an Announce message from a master. The purpose of this state is
+ to allow orderly addition of clocks to a domain. A port in this state
+ shall not place any PTP messages on its communication path except for
+ Pdelay_Req, Pdelay_Resp, Pdelay_Resp_Follow_Up, or signaling messages,
+ or management messages that are a required response to another
+ management message.
+
+ premaster:
+ The port shall behave in all respects as though it were in the MASTER
+ state except that it shall not place any messages on its communication
+ path except for Pdelay_Req, Pdelay_Resp, Pdelay_Resp_Follow_Up, signaling
+ or management messages.
+
+ master:
+ The port is behaving as a master port. It will periodically send announce
+ and sync messages.
+
+ passive:
+ The port shall not place any messages on its communication path except
+ for Pdelay_Req, Pdelay_Resp, Pdelay_Resp_Follow_Up, or signaling messages
+ or management messages that are a required response to another management
+ message.
+
+ uncalibrated:
+ This is a transient state to allow initialization of synchronization
+ servos, updating of data sets when a new master port has been selected,
+ and other implementation-specific activity.
+
+ slave:
+ The port is synchronizing to the selected master port."
+ REFERENCE "section 8.2.5.3.1 portDS.portState of [1]"
+ ::= { ptpPortDataSetEntry 6 }
+
+ ptpPortMinDelayReqInterval OBJECT-TYPE
+ SYNTAX Integer32 (-7..7)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This is the log to the base 2 of the delay request interval
+ in seconds. This speifies the time to the members devices to
+ send delay request messages when the port is in the master.
+ It specify the minimum permitted mean time interval between
+ successive Delay_Req messages, min delay request interval value is
+ a compromise between the fluctuation in link delay and startup time
+ and the communication and computation load imposed by transmission
+ of these messages."
+ REFERENCE "section 8.2.5.3.2 portDS.logMinDelayReqInterval of [1]"
+ DEFVAL { -4 }
+ ::= { ptpPortDataSetEntry 7 }
+
+ ptpPortLogAnnounceInterval OBJECT-TYPE
+ SYNTAX Integer32 (-3..6)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This is the log to the base 2 of the mean Announce message interval
+ in seconds."
+ REFERENCE "section 8.2.5.4.1 portDS.logAnnounceInterval of [1]"
+ DEFVAL { -3 }
+ ::= { ptpPortDataSetEntry 8 }
+
+ ptpPortAnnounceReceiptTimeout OBJECT-TYPE
+ SYNTAX Integer32 (3..10)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This is the Announce receipt time out value.
+ This should be an integral multiple of announce interval
+ in seconds"
+ REFERENCE "section 8.2.5.4.2 portDS.announceReceiptTimeout of [1]"
+ DEFVAL { 3 }
+ ::= { ptpPortDataSetEntry 9 }
+
+ ptpPortSyncInterval OBJECT-TYPE
+ SYNTAX Integer32 (-7..0)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This is the logarithm to the base 2 of the sync message interval
+ in seconds"
+ REFERENCE "section 8.2.5.4.3 portDS.logSyncInterval of [1]"
+ DEFVAL { -4 }
+ ::= { ptpPortDataSetEntry 10 }
+
+ ptpPortDelayMechanism OBJECT-TYPE
+ SYNTAX ClockMechanismType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This indicates the propagation delay measuring option used by the
+ port in computing meanpathDelay."
+ DEFVAL { e2e }
+ ::= { ptpPortDataSetEntry 11 }
+
+ ptpPortVersionNumber OBJECT-TYPE
+ SYNTAX Integer32 (2)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This indicates the PTP version in use on the port."
+ DEFVAL { 2 }
+ ::= { ptpPortDataSetEntry 12 }
+
+ ptpPortNotSlave OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This attribute is used in the alternate BMCA to prevent that a port
+ can be placed in the SLAVE state."
+ REFERENCE "Section 6.3.1 and 6.3.2 of [2]"
+ DEFVAL { true }
+ ::= { ptpPortDataSetEntry 13 }
+
+ ptpPortLocalPriority OBJECT-TYPE
+ SYNTAX Integer32 (1..255)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This attribute is used in the alternate BMCA as a tie-breaker in the
+ dataset comparison algorithm, in the event that all other previous
+ attributes of the datasets being compared are equal."
+ REFERENCE "Section 6.3.1 and 6.3.2 of [2]"
+ DEFVAL { 128 }
+ ::= { ptpPortDataSetEntry 14 }
+
+ ptpPortDestMacAddress OBJECT-TYPE
+ SYNTAX INTEGER {
+ forwardable (1),
+ nonForwardable (2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This attribute is used in to select the destination MAC address
+ inserted in the outgoing packets:
+ forwardable: 01-1B-19-00-00-00
+ nonForwardable: 01-80-C2-00-00-0E
+ "
+ REFERENCE "Section 6.2.6 of [3]"
+ DEFVAL { nonForwardable }
+ ::= { ptpPortDataSetEntry 15 }
+
+ ptpPortTxAsymmetryCompensation OBJECT-TYPE
+ SYNTAX Integer32 (-32768..32767)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This attribute is used to compensate in nanoseconds the asymmetric
+ delay. It works in TX direction."
+ DEFVAL { 0 }
+ ::= { ptpPortDataSetEntry 16 }
+
+ ptpPortRxAsymmetryCompensation OBJECT-TYPE
+ SYNTAX Integer32 (-32768..32767)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This attribute is used to compensate in nanoseconds the asymmetric
+ delay. It works in RX direction."
+ DEFVAL { 0 }
+ ::= { ptpPortDataSetEntry 17 }
+
+ ptpPortRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "RowStatus for creating the entries into this table.
+ This object can't be modified."
+ ::= { ptpPortDataSetEntry 18 }
+
+ --
+ -- Ptp Port alarms. Contains alarms of a particular PTP port
+ --
+
+ ptpPortAlarmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PtpPortAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table Contains PTP alarm information
+ for a particular port of boundary or an ordinary clock."
+ ::= { ptpPortDataSet 2 }
+
+ ptpPortAlarmEntry OBJECT-TYPE
+ SYNTAX PtpPortAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Contains PTP alarm information for a particular port."
+ INDEX { ptpClockDomainIndex,
+ ptpClockTypeIndex,
+ ptpClockInstanceIndex,
+ ptpPortIndex
+ }
+ ::= { ptpPortAlarmTable 1 }
+
+ PtpPortAlarmEntry ::= SEQUENCE {
+ ptpPortFaultyAlarm AlarmStatus,
+ ptpPortInitializingAlarm AlarmStatus,
+ ptpPortUncalibratedAlarm AlarmStatus,
+ ptpPortListeningAlarm AlarmStatus,
+ ptpPortActiveStatus AlarmStatus
+ }
+
+ ptpPortFaultyAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This alarm is raised when ptpPortState is set to faulty(2)."
+ ::= { ptpPortAlarmEntry 1 }
+
+ ptpPortInitializingAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This alarm is raised when ptpPortState is set to initializing(1).
+ "
+ ::= { ptpPortAlarmEntry 2 }
+
+ ptpPortUncalibratedAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This alarm is raised when ptpPortState is set to uncalibrated(8).
+ "
+ ::= { ptpPortAlarmEntry 3 }
+
+ ptpPortListeningAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This alarm is raised when ptpPortState is set to listening(4).
+ "
+ ::= { ptpPortAlarmEntry 4 }
+
+ ptpPortActiveStatus OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This alarm is raised when ptpPortState is set to slave(9).
+ "
+ ::= { ptpPortAlarmEntry 5 }
+
+ --
+ -- Ptp Radio Port alarms. Contains alarms of a Radio PTP port
+ --
+
+ ptpPortRadioAlarmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PtpPortRadioAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table Contains PTP alarm information
+ for a radio port of boundary or an ordinary clock."
+ ::= { ptpPortDataSet 3 }
+
+ ptpPortRadioAlarmEntry OBJECT-TYPE
+ SYNTAX PtpPortRadioAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Contains PTP alarm information for a radio port."
+ INDEX { ptpClockDomainIndex,
+ ptpClockTypeIndex,
+ ptpClockInstanceIndex,
+ ptpPortIndex
+ }
+ ::= { ptpPortRadioAlarmTable 1 }
+
+ PtpPortRadioAlarmEntry ::= SEQUENCE {
+ ptpPortRadioCapacityAlarm AlarmStatus
+ }
+
+ ptpPortRadioCapacityAlarm OBJECT-TYPE
+ SYNTAX AlarmStatus
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This alarm is raised when the capacity of a radio link
+ is not big enough to transport PTP packets."
+ ::= { ptpPortRadioAlarmEntry 1 }
+
+ --
+ -- Ptp Port alarm severities.
+ --
+
+ ptpPortFaultyAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object defines the severity associated to
+ ptpPortFaultyAlarm and enables or disables the
+ sending of the SNMP Trap on the alarm status transition.
+ "
+ DEFVAL { majorTrapEnable }
+ ::= { ptpPortDataSet 4 }
+
+ ptpPortInitializingAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object defines the severity associated to
+ ptpPortInitializingAlarm and enables or disables the
+ sending of the SNMP Trap on the alarm status transition.
+ "
+ DEFVAL { warningTrapEnable }
+ ::= { ptpPortDataSet 5 }
+
+ ptpPortUncalibratedAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object defines the severity associated to
+ ptpPortUncalibratedAlarm and enables or disables the
+ sending of the SNMP Trap on the alarm status transition.
+ "
+ DEFVAL { warningTrapEnable }
+ ::= { ptpPortDataSet 6 }
+
+ ptpPortListeningAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object defines the severity associated to
+ ptpPortListeningAlarm and enables or disables the
+ sending of the SNMP Trap on the alarm status transition.
+ "
+ DEFVAL { warningTrapEnable }
+ ::= { ptpPortDataSet 7 }
+
+ ptpPortActiveStatusSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object enables or disables the sending of the SNMP Trap
+ on ptpPortActiveStatus transition.
+ "
+ DEFVAL { statusTrapEnable }
+ ::= { ptpPortDataSet 8 }
+
+ ptpPortRadioCapacityAlarmSeverityCode OBJECT-TYPE
+ SYNTAX AlarmSeverityCode
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object enables or disables the sending of the SNMP Trap
+ on ptpPortRadioCapacityAlarm transition.
+ "
+ DEFVAL { majorTrapEnable }
+ ::= { ptpPortDataSet 9 }
+
+--
+------- End of Ptp Port data set.
+
+
+------- Begin of PTP Radio Asymmetry data set.
+-- Configuration asymmetry of a specific Radio unit.
+--
+
+ ptpRadioAsymmetryDataSetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF PtpRadioAsymmetryDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table contains delay offset for asymmetries compensation for the Radio unit."
+ ::= { ptpRadioAsymmetryDataSet 1 }
+
+ ptpRadioAsymmetryDataSetEntry OBJECT-TYPE
+ SYNTAX PtpRadioAsymmetryDataSetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Each ntry contains delay offset for asymmetries compensation for a specific Radio unit."
+ INDEX { ptpRadioBrIndex
+ }
+ ::= { ptpRadioAsymmetryDataSetTable 1 }
+
+ PtpRadioAsymmetryDataSetEntry ::= SEQUENCE {
+ ptpRadioBrIndex Integer32,
+ ptpRadioOffset Integer32
+ }
+
+
+ ptpRadioBrIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This is the index in radioTable of this unit.
+ This object can't be modified."
+ ::= { ptpRadioAsymmetryDataSetEntry 1 }
+
+
+ ptpRadioOffset OBJECT-TYPE
+ SYNTAX Integer32 (-32768..32767)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is an offset in nanoseconds for asymmetry compensation and
+ can have both positive and negative values."
+ DEFVAL { 0 }
+ ::= { ptpRadioAsymmetryDataSetEntry 2 }
+
+--
+------- End of PTP Radio Asymmetry data set.
+
+END
+
+