summaryrefslogtreecommitdiff
path: root/MIBS/transition/TN-LINK-OAM-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/transition/TN-LINK-OAM-MIB')
-rw-r--r--MIBS/transition/TN-LINK-OAM-MIB715
1 files changed, 715 insertions, 0 deletions
diff --git a/MIBS/transition/TN-LINK-OAM-MIB b/MIBS/transition/TN-LINK-OAM-MIB
new file mode 100644
index 0000000..81c0021
--- /dev/null
+++ b/MIBS/transition/TN-LINK-OAM-MIB
@@ -0,0 +1,715 @@
+-- *****************************************************************
+-- TN-LINK-OAM-MIB
+--
+-- Copyright (c) 2013, Transition Networks Inc.
+-- All rights reserved.
+-- *****************************************************************
+TN-LINK-OAM-MIB DEFINITIONS ::= BEGIN
+IMPORTS
+ OBJECT-TYPE, Counter32, Unsigned32,
+ Integer32, Counter64
+ FROM SNMPv2-SMI
+ -- from [RFC2578]
+ TimeStamp, TruthValue, DisplayString
+ FROM SNMPv2-TC
+ -- from [RFC2579]
+ ifIndex
+ FROM IF-MIB
+ -- from [RFC2863]
+ dot3OamEntry, dot3OamStatsEntry, dot3OamPeerEntry,
+ dot3OamEventConfigEntry
+ FROM DOT3-OAM-MIB
+ tnProducts
+ FROM TRANSITION-SMI;
+
+ tnLinkOamMIB MODULE-IDENTITY
+ LAST-UPDATED "201305280000Z"
+ ORGANIZATION "Transition Networks, Inc."
+ CONTACT-INFO
+ "Transition Networks
+ Technical Support
+
+ 10900 Red Circle Drive
+ Minnetonka, MN 55343 USA
+ Tel: +1-800-526-9267
+
+ E-mail: techsupport@transition.com
+ "
+ DESCRIPTION
+ "The mib module for managing Link OAM."
+::= { tnProducts 140 }
+
+--
+-- Sections of the Ethernet OAM MIB
+
+ tnLinkOamNotifications OBJECT IDENTIFIER ::= { tnLinkOamMIB 0 }
+ tnLinkOamObjects OBJECT IDENTIFIER ::= { tnLinkOamMIB 1 }
+ tnLinkOamConformance OBJECT IDENTIFIER ::= { tnLinkOamMIB 2 }
+
+-- ***************************************************************
+--
+-- Link OAM Port Configuration Group
+--
+
+tnLinkOamPortConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TnLinkOamPortConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table allows the user to inspect the current Link
+ OAM port configurations, and change them as well.
+ "
+ ::= { tnLinkOamObjects 1 }
+
+tnLinkOamPortConfigEntry OBJECT-TYPE
+ SYNTAX TnLinkOamPortConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the table that contains information of
+ OAM port configurations.
+ "
+ AUGMENTS { dot3OamEntry }
+ ::= { tnLinkOamPortConfigTable 1 }
+
+TnLinkOamPortConfigEntry ::=
+ SEQUENCE {
+ tnLinkOamLoopbackSupport INTEGER,
+ tnLinkOamLinkMonitorSupport INTEGER,
+ tnLinkMIBRetrievalSupport INTEGER,
+ tnLinkOamLoopbackOperation INTEGER
+ }
+
+tnLinkOamLoopbackSupport OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls whether the loopback support is enabled for the
+ switch port. Link OAM remote loopback can be used for fault
+ localization and link performance testing. Enabling the
+ loopback support will allow the DTE to execute the remote
+ loopback command that helps in the fault detection.
+ "
+ ::= { tnLinkOamPortConfigEntry 1 }
+
+tnLinkOamLinkMonitorSupport OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls whether the Link Monitor support is enabled for the
+ switch port. On enabling the Link Monitor support, the DTE
+ supports event notification that permits the inclusion of
+ diagnostic information.
+ "
+ ::= { tnLinkOamPortConfigEntry 2 }
+
+tnLinkMIBRetrievalSupport OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Controls whether the MIB Retrieval Support is enabled for
+ the switch port. On enabling the MIB retrieval support,
+ the DTE supports polling of various Link OAM based MIB
+ variables' contents.
+ "
+ ::= { tnLinkOamPortConfigEntry 3 }
+
+tnLinkOamLoopbackOperation OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If the Loopback support is enabled, enabling this field
+ will start a loopback operation for the port.
+ "
+ ::= { tnLinkOamPortConfigEntry 4 }
+
+-- **************************************************************
+--
+-- Ethernet OAM Monitor Groups
+--
+
+-- **************************************************************
+--
+-- Ethernet OAM Port Statistics Table
+--
+
+tnLinkOamStatisticsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TnLinkOamStatisticsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains statistics for the OAM function on a
+ particular Ethernet-like interface. There is an entry in the
+ table for every entry in the tnLinkOamTable.
+
+ The displayed counters represent the total number of OAM
+ frames received and transmitted for the selected port.
+ Discontinuities of these counter can occur at re-initialization
+ of the management system.
+ "
+ ::= { tnLinkOamObjects 2 }
+
+tnLinkOamStatisticsEntry OBJECT-TYPE
+ SYNTAX TnLinkOamStatisticsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the table containing statistics information on
+ the Ethernet OAM function for a single Ethernet-like
+ interface.
+ "
+ AUGMENTS { dot3OamStatsEntry }
+ ::= { tnLinkOamStatisticsTable 1 }
+
+TnLinkOamStatisticsEntry ::=
+ SEQUENCE {
+ tnLinkOamLinkfaultPDUsRx Counter32,
+ tnLinkOamLinkfaultPDUsTx Counter32,
+ tnLinkOamDyingGaspRx Counter32,
+ tnLinkOamDyingGaspTx Counter32,
+ tnLinkOamCriticalEventPDUsRx Counter32,
+ tnLinkOamCriticalEventPDUsTx Counter32
+ }
+
+tnLinkOamLinkfaultPDUsRx OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "frames"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of the number of Link fault PDU's received."
+ ::= { tnLinkOamStatisticsEntry 1 }
+
+tnLinkOamLinkfaultPDUsTx OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "frames"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of the number of Link fault PDU's transmitted."
+ ::= { tnLinkOamStatisticsEntry 2 }
+
+tnLinkOamDyingGaspRx OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "frames"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of the number of Dying Gasp events received."
+ ::= { tnLinkOamStatisticsEntry 3 }
+
+tnLinkOamDyingGaspTx OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "frames"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of the number of Dying Gasp events transmitted."
+ ::= { tnLinkOamStatisticsEntry 4 }
+
+tnLinkOamCriticalEventPDUsRx OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "frames"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of the number of Critical event PDU's received."
+ ::= { tnLinkOamStatisticsEntry 5 }
+
+tnLinkOamCriticalEventPDUsTx OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "frames"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A count of the number of Critical event PDU's transmitted."
+ ::= { tnLinkOamStatisticsEntry 6 }
+
+-- **************************************************************
+--
+-- Ethernet OAM Port Configuration Status Group
+--
+
+-- Ethernet OAM Local Port Configuration Status Table
+-- Included PDU Permission
+tnLinkOamLocalPortConfigStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TnLinkOamLocalPortConfigStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table provides Local Link OAM configuration operational
+ status."
+ ::= { tnLinkOamObjects 3 }
+
+tnLinkOamLocalPortConfigStatusEntry OBJECT-TYPE
+ SYNTAX TnLinkOamLocalPortConfigStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the table containing information of Peer Link
+ OAM configuration operational status."
+ AUGMENTS { dot3OamEntry }
+ ::= { tnLinkOamLocalPortConfigStatusTable 1 }
+
+TnLinkOamLocalPortConfigStatusEntry ::=
+ SEQUENCE {
+ tnLinkOamPDUPermission INTEGER,
+ tnLinkOamLocalMultiplexerState INTEGER,
+ tnLinkOamLocalParserState INTEGER,
+ tnLinkOamLocalOrganizationalUniqueIdentifi DisplayString
+ }
+
+tnLinkOamPDUPermission OBJECT-TYPE
+ SYNTAX INTEGER {
+ linkfault(1),
+ receiveonly(2),
+ informationexchangeonly(3),
+ any(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This field is available only for the Local DTE. It
+ displays the current permission rules set for the
+ local DTE. Possible values are 'Link fault', 'Receive
+ only', 'Information exchange only', 'ANY'."
+ ::= { tnLinkOamLocalPortConfigStatusEntry 1 }
+
+tnLinkOamLocalMultiplexerState OBJECT-TYPE
+ SYNTAX INTEGER {
+ forwarding(1),
+ discarding(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "When in forwarding state, the Device is forwarding
+ non-OAMPDUs to the lower sublayer. Incase of
+ discarding, the device discards all the non-OAMPDU's."
+ ::= { tnLinkOamLocalPortConfigStatusEntry 2 }
+
+tnLinkOamLocalParserState OBJECT-TYPE
+ SYNTAX INTEGER {
+ forwarding(1),
+ loopback(2),
+ discarding(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "When in forwarding state, Device is forwarding
+ non-OAMPDUs to higher sublayer. When in loopback,
+ Device is looping back non-OAMPDUs to the lower
+ sublayer. When in discarding state, Device is
+ discarding non-OAMPDUs."
+ ::= { tnLinkOamLocalPortConfigStatusEntry 3 }
+
+tnLinkOamLocalOrganizationalUniqueIdentifi OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "24-bit Organizationally Unique Identifier of the
+ vendor."
+ ::= { tnLinkOamLocalPortConfigStatusEntry 4 }
+
+-- Ethernet OAM Peer Port Configuration Status Table
+
+tnLinkOamPeerPortConfigStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TnLinkOamPeerPortConfigStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table provides Peer Link OAM configuration operational
+ status."
+ ::= { tnLinkOamObjects 4 }
+
+tnLinkOamPeerPortConfigStatusEntry OBJECT-TYPE
+ SYNTAX TnLinkOamPeerPortConfigStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the table containing information of Peer Link
+ OAM configuration operational status."
+ AUGMENTS { dot3OamPeerEntry }
+ ::= { tnLinkOamPeerPortConfigStatusTable 1 }
+
+TnLinkOamPeerPortConfigStatusEntry ::=
+ SEQUENCE {
+ tnLinkOamPeerMultiplexerState INTEGER,
+ tnLinkOamPeerParserState INTEGER,
+ tnLinkOamPeerOrganizationalUniqueIdentifi DisplayString
+}
+
+tnLinkOamPeerMultiplexerState OBJECT-TYPE
+ SYNTAX INTEGER {
+ forwarding(1),
+ discarding(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "When in forwarding state, the Device is forwarding
+ non-OAMPDUs to the lower sublayer. Incase of
+ discarding, the device discards all the non-OAMPDU's."
+ ::= { tnLinkOamPeerPortConfigStatusEntry 1 }
+
+tnLinkOamPeerParserState OBJECT-TYPE
+ SYNTAX INTEGER {
+ forwarding(1),
+ loopback(2),
+ discarding(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "When in forwarding state, Device is forwarding
+ non-OAMPDUs to higher sublayer. When in loopback,
+ Device is looping back non-OAMPDUs to the lower
+ sublayer. When in discarding state, Device is
+ discarding non-OAMPDUs."
+ ::= { tnLinkOamPeerPortConfigStatusEntry 2 }
+
+tnLinkOamPeerOrganizationalUniqueIdentifi OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "24-bit Organizationally Unique Identifier of the
+ vendor."
+ ::= { tnLinkOamPeerPortConfigStatusEntry 3 }
+
+-- **************************************************************
+--
+-- Ethernet OAM Link Event Status Objects
+--
+
+--***************************************************************
+-- Frame Error Status Table
+
+tnLinkOamLinkEventStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TnLinkOamLinkEventStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table shows frame error status."
+ ::= { tnLinkOamObjects 5 }
+
+tnLinkOamLinkEventStatusEntry OBJECT-TYPE
+ SYNTAX TnLinkOamLinkEventStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the table containing information of
+ frame error status."
+ INDEX { ifIndex, tnLinkOamLocationIndex }
+ ::= { tnLinkOamLinkEventStatusTable 1 }
+
+TnLinkOamLinkEventStatusEntry ::=
+ SEQUENCE {
+ tnLinkOamLocationIndex Unsigned32,
+ tnLinkOamSequenceNumber Counter32,
+ tnLinkOamFrameErrorEventTimestamp TimeStamp,
+ tnLinkOamFrameErrorEventWindow Counter32,
+ tnLinkOamFrameErrorEventThreshold Counter32,
+ tnLinkOamFrameErrors Counter32,
+ tnLinkOamTotalFrameErrors Counter64,
+ tnLinkOamTotalFrameErrorEvents Counter32,
+ tnLinkOamFramePeriodErrorEventTimestamp TimeStamp,
+ tnLinkOamFramePeriodErrorEventWindow Counter32,
+ tnLinkOamFramePeriodErrorEventThreshold Counter32,
+ tnLinkOamFramePeriodsErrors Counter32,
+ tnLinkOamTotalFramePeriodsErrors Counter64,
+ tnLinkOamTotalFramePerioderrorEvents Counter32,
+ tnLinkOamSymbolPeriodErrorEventTimestamp TimeStamp,
+ tnLinkOamSymbolPeriodErrorEventWindow Counter64,
+ tnLinkOamSymbolPeriodErrorEventThreshold Counter64,
+ tnLinkOamSymbolPeriodsErrors Counter64,
+ tnLinkOamSymbolFramePeriodErrors Counter64,
+ tnLinkOamTotalSymbolFramePerioderrorEvents Counter32,
+ tnLinkOamEventSecondsSummaryTimestamp TimeStamp,
+ tnLinkOamEventSecondsSummaryWindow Counter32,
+ tnLinkOamEventSecondsSummaryThreshold Counter32,
+ tnLinkOamEventSecondsSummarysEvents Counter32,
+ tnLinkOamEventSecondsSummaryErrorTotal Counter32,
+ tnLinkOamTotalEventSecondsSummaryEventTotal Counter32
+ }
+
+tnLinkOamLocationIndex OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index of the loacation of the OAM unit event status
+ accessed.
+ When the value of index is '1', the table will display
+ the Event status for the Local OAM unit. While the value
+ is '2', the table will display the status for the Peer
+ for the respective port."
+ ::= { tnLinkOamLinkEventStatusEntry 1 }
+
+tnLinkOamSequenceNumber OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This two-octet field indicates the total number of
+ events occurred at the remote end."
+ ::= { tnLinkOamLinkEventStatusEntry 2 }
+
+tnLinkOamFrameErrorEventTimestamp OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This two-octet field indicates the time reference
+ when the event was generated, in terms of 100 ms
+ intervals."
+ ::= { tnLinkOamLinkEventStatusEntry 3 }
+
+tnLinkOamFrameErrorEventWindow OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This two-octet field indicates the duration of the
+ period in terms of 100 ms intervals.
+ 1) The default value is one second.
+ 2) The lower bound is one second.
+ 3) The upper bound is one minute."
+ ::= { tnLinkOamLinkEventStatusEntry 4 }
+
+tnLinkOamFrameErrorEventThreshold OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This four-octet field indicates the number of detected
+ errored frames in the period is required to be equal to
+ or greater than in order for the event to be generated.
+ 1) The default value is one frame error.
+ 2) The lower bound is zero frame errors.
+ 3) The upper bound is unspecified."
+ ::= { tnLinkOamLinkEventStatusEntry 5 }
+
+tnLinkOamFrameErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This four-octet field indicates the number of detected
+ errored frames in the period."
+ ::= { tnLinkOamLinkEventStatusEntry 6 }
+
+tnLinkOamTotalFrameErrors OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This eight-octet field indicates the sum of errored
+ frames that have been detected since the OAM sublayer
+ was reset."
+ ::= { tnLinkOamLinkEventStatusEntry 7 }
+
+tnLinkOamTotalFrameErrorEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This four-octet field indicates the number of Errored
+ Frame Event TLVs that have been generated since the
+ OAM sublayer was reset."
+ ::= { tnLinkOamLinkEventStatusEntry 8 }
+
+tnLinkOamFramePeriodErrorEventTimestamp OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This two-octet field indicates the time reference
+ when the event was generated, in terms of 100 ms
+ intervals."
+ ::= { tnLinkOamLinkEventStatusEntry 9 }
+
+tnLinkOamFramePeriodErrorEventWindow OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This four-octet field indicates the duration of period
+ in terms of frames."
+ ::= { tnLinkOamLinkEventStatusEntry 10 }
+
+tnLinkOamFramePeriodErrorEventThreshold OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This four-octet field indicates the number of errored
+ frames in the period is required to be equal to or
+ greater than in order for the event to be generated."
+ ::= { tnLinkOamLinkEventStatusEntry 11 }
+
+tnLinkOamFramePeriodsErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This four-octet field indicates the number of frame
+ errors in the period."
+ ::= { tnLinkOamLinkEventStatusEntry 12 }
+
+tnLinkOamTotalFramePeriodsErrors OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This eight-octet field indicates the sum of frame
+ errors that have been detected since the OAM sublayer
+ was reset."
+ ::= { tnLinkOamLinkEventStatusEntry 13 }
+
+tnLinkOamTotalFramePerioderrorEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This four-octet field indicates the number of Errored
+ Frame Period Event TLVs that have been generated since
+ the OAM sublayer was reset."
+ ::= { tnLinkOamLinkEventStatusEntry 14 }
+
+tnLinkOamSymbolPeriodErrorEventTimestamp OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This two-octet field indicates the time reference when
+ the event was generated, in terms of 100 ms intervals."
+ ::= { tnLinkOamLinkEventStatusEntry 15 }
+
+tnLinkOamSymbolPeriodErrorEventWindow OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This eight-octet field indicates the number of symbols
+ in the period."
+ ::= { tnLinkOamLinkEventStatusEntry 16 }
+
+tnLinkOamSymbolPeriodErrorEventThreshold OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This eight-octet field indicates the number of errored
+ symbols in the period is required to be equal to or
+ greater than in order for the event to be generated."
+ ::= { tnLinkOamLinkEventStatusEntry 17 }
+
+tnLinkOamSymbolPeriodsErrors OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This eight-octet field indicates the number of symbol
+ errors in the period."
+ ::= { tnLinkOamLinkEventStatusEntry 18 }
+
+tnLinkOamSymbolFramePeriodErrors OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This eight-octet field indicates the sum of symbol
+ errors since the OAM sublayer was reset."
+ ::= { tnLinkOamLinkEventStatusEntry 19 }
+
+tnLinkOamTotalSymbolFramePerioderrorEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This four-octet field indicates the number of Errored
+ Symbol Period Event TLVs that have been generated since
+ the OAM sublayer was reset."
+ ::= { tnLinkOamLinkEventStatusEntry 20 }
+
+tnLinkOamEventSecondsSummaryTimestamp OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This two-octet field indicates the time reference when
+ the event was generated, in terms of 100 ms intervals,
+ encoded as a 16-bit unsigned integer."
+ ::= { tnLinkOamLinkEventStatusEntry 21 }
+
+tnLinkOamEventSecondsSummaryWindow OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This two-octet field indicates the duration of the
+ period in terms of 100 ms intervals, encoded as a
+ 16-bit unsigned integer."
+ ::= { tnLinkOamLinkEventStatusEntry 22 }
+
+tnLinkOamEventSecondsSummaryThreshold OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This two-octet field indicates the number of errored
+ frame seconds in the period is required to be equal
+ to or greater than in order for the event to be
+ generated, encoded as a 16-bit unsigned integer."
+ ::= { tnLinkOamLinkEventStatusEntry 23 }
+
+tnLinkOamEventSecondsSummarysEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This two-octet field indicates the number of errored
+ frame seconds in the period, encoded as a 16-bit
+ unsigned integer."
+ ::= { tnLinkOamLinkEventStatusEntry 24 }
+
+tnLinkOamEventSecondsSummaryErrorTotal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This four-octet field indicates the sum of errored
+ frame seconds that have been detected since the OAM
+ sublayer was reset."
+ ::= { tnLinkOamLinkEventStatusEntry 25 }
+
+tnLinkOamTotalEventSecondsSummaryEventTotal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This four-octet field indicates the number of Errored
+ Frame Seconds Summary Event TLVs that have been generated
+ since the OAM sublayer was reset, encoded as a 32bit
+ unsigned integer."
+ ::= { tnLinkOamLinkEventStatusEntry 26 }
+END