diff --git a/MIBS/ubiquoss/UBQS-ENVMON-MIB b/MIBS/ubiquoss/UBQS-ENVMON-MIB new file mode 100644 index 0000000..c3c3a4f --- /dev/null +++ b/MIBS/ubiquoss/UBQS-ENVMON-MIB @@ -0,0 +1,666 @@ +-- *****************************************************************
+-- UBQS-ENVMON-MIB: Ubiquoss Environmental Monitor MIB file
+--
+-- June 2009 by Hyung Eun Park
+--
+-- Copyright (c) 2009 by Ubiquoss, Corp.
+-- All rights reserved.
+-- *****************************************************************
+--
+
+UBQS-ENVMON-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY,
+ OBJECT-TYPE,
+ NOTIFICATION-TYPE,
+ Gauge32,
+ Integer32
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION,
+ DisplayString,
+ TruthValue
+ FROM SNMPv2-TC
+ MODULE-COMPLIANCE,
+ OBJECT-GROUP,
+ NOTIFICATION-GROUP
+ FROM SNMPv2-CONF
+ ubiMgmtv2
+ FROM UBQS-SMI;
+
+
+ubiEnvMonMIB MODULE-IDENTITY
+ LAST-UPDATED "200906250000Z"
+ ORGANIZATION "Ubiquoss Corp."
+ CONTACT-INFO
+ " Ubiquoss
+ Customer Service
+
+ Postal: 24F Milennium B/D,
+ 467-12, Dogok-Dong,
+ GangNam-Gu, Seoul 135-270
+ Korea
+
+ Tel: 82-2-2190-3100"
+ DESCRIPTION
+ "The UBQS-ENVMON-MIB is used for getting
+ the environment information of the system."
+ ::= { ubiMgmtv2 2 }
+
+
+-- *****************************************************************
+-- Type Convention
+-- *****************************************************************
+UbiEnvMonState ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Represents the state of a device being monitored.
+ Valid values are:
+
+ normal(1): the environment is good, such as low
+ temperature.
+
+ warning(2): the environment is bad, such as temperature
+ above normal operation range but not too
+ high.
+
+ critical(3): the environment is very bad, such as
+ temperature much higher than normal
+ operation limit.
+
+ shutdown(4): the environment is the worst, the system
+ should be shutdown immediately.
+
+ notPresent(5): the environmental monitor is not present,
+ such as temperature sensors do not exist.
+
+ notFunctioning(6): the environmental monitor does not
+ function properly.
+ "
+ SYNTAX INTEGER {
+ normal(1),
+ warning(2),
+ critical(3),
+ shutdown(4),
+ notPresent(5),
+ notFunctioning(6)
+ }
+
+-- *****************************************************************
+-- ubiEnvMonMIB
+-- *****************************************************************
+
+ubiEnvMonObjects OBJECT IDENTIFIER ::= { ubiEnvMonMIB 1 }
+ubiEnvMonMIBNotificationEnables OBJECT IDENTIFIER ::= { ubiEnvMonMIB 2 }
+ubiEnvMonMIBNotificationPrefix OBJECT IDENTIFIER ::= { ubiEnvMonMIB 3 }
+ubiEnvMonMIBConformance OBJECT IDENTIFIER ::= { ubiEnvMonMIB 4 }
+
+
+
+-- *****************************************************************
+-- ubiEnvMonTemperatureTable
+-- *****************************************************************
+
+ ubiEnvMonTemperatureTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UbiEnvMonTemperatureEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of ambient temperature status maintained by the
+ environmental monitor."
+ ::= { ubiEnvMonObjects 1 }
+
+ ubiEnvMonTemperatureEntry OBJECT-TYPE
+ SYNTAX UbiEnvMonTemperatureEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the ambient temperature status table, representing
+ the status of the associated testpoint maintained by the
+ environmental monitor."
+ INDEX { ubiEnvMonTemperatureIndex }
+ ::= { ubiEnvMonTemperatureTable 1 }
+
+ UbiEnvMonTemperatureEntry ::=
+ SEQUENCE {
+ ubiEnvMonTemperatureIndex Integer32,
+ ubiEnvMonTemperatureDescr DisplayString,
+ ubiEnvMonTemperatureValue Gauge32,
+ ubiEnvMonTemperatureHighThreshold Integer32,
+ ubiEnvMonTemperatureLowThreshold Integer32,
+ -- ubiEnvMonTemperatureLastShutdown Integer32,
+ ubiEnvMonTemperatureState UbiEnvMonState
+ }
+
+
+ ubiEnvMonTemperatureIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique index for the testpoint being instrumented.
+ This index is for SNMP purposes only, and has no
+ intrinsic meaning."
+ ::= { ubiEnvMonTemperatureEntry 1 }
+
+ ubiEnvMonTemperatureDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Textual description of the testpoint
+ being instrumented."
+ ::= { ubiEnvMonTemperatureEntry 2 }
+
+ ubiEnvMonTemperatureValue OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "degrees Celsius"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current measurement of the testpoint
+ being instrumented."
+ ::= { ubiEnvMonTemperatureEntry 3 }
+
+ ubiEnvMonTemperatureHighThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "degrees Celsius"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A high threshold for the temperature.
+ If a particular value isn't set, this object
+ displays the default value."
+ ::= { ubiEnvMonTemperatureEntry 4 }
+
+ ubiEnvMonTemperatureLowThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "degrees Celsius"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A low threshold for the temperature.
+ If a particular value isn't set, this object
+ displays the default value."
+ ::= { ubiEnvMonTemperatureEntry 5 }
+
+-- ubiEnvMonTemperatureLastShutdown OBJECT-TYPE
+ -- SYNTAX Integer32
+ -- UNITS "degrees Celsius"
+ -- MAX-ACCESS read-only
+ -- STATUS current
+ -- DESCRIPTION
+ -- "The value of the associated instance of the object
+ -- ubiEnvMonTemperatureStatusValue at the time an emergency
+ -- shutdown of the managed device was last initiated. "
+ -- ::= { ubiEnvMonTemperatureEntry 5 }
+
+ ubiEnvMonTemperatureState OBJECT-TYPE
+ SYNTAX UbiEnvMonState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the testpoint being instrumented.
+ Represents the temperature state of a device being monitored.
+ Valid values are:
+
+ normal(1): the environment is good, such as low
+ temperature.
+
+ warning(2): the environment is bad, such as temperature
+ above normal operation range but not too
+ high.
+
+ critical(3): the environment is very bad, such as
+ temperature much higher than normal
+ operation limit.
+
+ notPresent(5): the environmental monitor is not present,
+ such as temperature sensors do not exist.
+ "
+ ::= { ubiEnvMonTemperatureEntry 6 }
+
+
+-- *****************************************************************
+-- ubiEnvMonFanTable
+-- ****************************************************************
+
+ ubiEnvMonFanTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UbiEnvMonFanEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of fan status maintained by the environmental
+ monitor."
+ ::= { ubiEnvMonObjects 2 }
+
+ ubiEnvMonFanEntry OBJECT-TYPE
+ SYNTAX UbiEnvMonFanEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the fan status table, representing the status of
+ the associated fan maintained by the environmental monitor."
+ INDEX { ubiEnvMonFanIndex }
+ ::= { ubiEnvMonFanTable 1 }
+
+ UbiEnvMonFanEntry ::=
+ SEQUENCE {
+ ubiEnvMonFanIndex Integer32,
+ ubiEnvMonFanDescr DisplayString,
+ ubiEnvMonFanState UbiEnvMonState
+ }
+
+ ubiEnvMonFanIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique index for the fan being instrumented.
+ This index is for SNMP purposes only, and has no
+ intrinsic meaning."
+ ::= { ubiEnvMonFanEntry 1 }
+
+ ubiEnvMonFanDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Textual description of the fan being instrumented."
+ ::= { ubiEnvMonFanEntry 2 }
+
+ ubiEnvMonFanState OBJECT-TYPE
+ SYNTAX UbiEnvMonState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the fan being instrumented.
+ Represents the fan state of a device being monitored.
+ Valid values are:
+
+ normal(1): the environment is good, such as low
+ temperature.
+
+ notPresent(5): the environmental monitor is not present,
+ such as temperature sensors do not exist.
+
+ notFunctioning(6): the environmental monitor does not
+ function properly.
+ "
+
+ ::= { ubiEnvMonFanEntry 3 }
+
+
+
+-- *****************************************************************
+-- ubiEnvMonSupplyTable
+-- ****************************************************************
+
+ ubiEnvMonSupplyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UbiEnvMonSupplyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of power supply status maintained by the
+ environmental monitor card."
+ ::= { ubiEnvMonObjects 3 }
+
+ ubiEnvMonSupplyEntry OBJECT-TYPE
+ SYNTAX UbiEnvMonSupplyEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the power supply status table, representing the
+ status of the associated power supply maintained by the
+ environmental monitor card."
+ INDEX { ubiEnvMonSupplyIndex }
+ ::= { ubiEnvMonSupplyTable 1 }
+
+ UbiEnvMonSupplyEntry ::=
+ SEQUENCE {
+ ubiEnvMonSupplyIndex Integer32,
+ ubiEnvMonSupplyDescr DisplayString,
+ ubiEnvMonSupplyState UbiEnvMonState,
+ ubiEnvMonSupplySource INTEGER,
+ ubiEnvMonExternalAlarmAc INTEGER,
+ ubiEnvMonExternalAlarmUnit INTEGER
+ }
+
+ ubiEnvMonSupplyIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Unique index for the power supply being instrumented.
+ This index is for SNMP purposes only, and has no
+ intrinsic meaning."
+ ::= { ubiEnvMonSupplyEntry 1 }
+
+ ubiEnvMonSupplyDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Textual description of the power supply
+ being instrumented."
+ ::= { ubiEnvMonSupplyEntry 2 }
+
+ ubiEnvMonSupplyState OBJECT-TYPE
+ SYNTAX UbiEnvMonState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the power supply
+ being instrumented.
+ Represents the power state of a device being monitored.
+ Valid values are:
+
+ normal(1): the environment is good, such as low
+ temperature.
+
+ notPresent(5): the environmental monitor is not present,
+ such as temperature sensors do not exist.
+
+ notFunctioning(6): the environmental monitor does not
+ function properly.
+ "
+ ::= { ubiEnvMonSupplyEntry 3 }
+
+ ubiEnvMonSupplySource OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(0),
+ ac(1),
+ dc(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power supply source.
+ ac - AC power supply
+ dc - DC power supply"
+ ::= { ubiEnvMonSupplyEntry 4 }
+
+ ubiEnvMonExternalAlarmAc OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ fail(2)
+ } MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power supply convertor AC.
+ nomal (1)
+ fail (2)"
+ ::= { ubiEnvMonSupplyEntry 5 }
+
+ ubiEnvMonExternalAlarmUnit OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ fail(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The power supply convertor unit.
+ nomal (1)
+ fail (2)"
+ ::= { ubiEnvMonSupplyEntry 6 }
+
+
+-- *****************************************************************
+-- ubiEnvMonSupplyChannelTable
+-- ****************************************************************
+
+ ubiEnvMonSupplyChannelTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UbiEnvMonSupplyChannelEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table represents the extension status
+ for DC power supply."
+ ::= { ubiEnvMonObjects 4 }
+
+ ubiEnvMonSupplyChannelEntry OBJECT-TYPE
+ SYNTAX UbiEnvMonSupplyChannelEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in this table, representing the extended status of
+ the associated DC power supply maintained by
+ the environmental monitor card."
+ INDEX { ubiEnvMonSupplyIndex, ubiEnvMonSupplyChannelType }
+ ::= { ubiEnvMonSupplyChannelTable 1 }
+
+ UbiEnvMonSupplyChannelEntry ::=
+ SEQUENCE {
+ ubiEnvMonSupplyChannelType INTEGER,
+ ubiEnvMonSupplyChannelState UbiEnvMonState
+ }
+
+ ubiEnvMonSupplyChannelType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ dc_48v_a(1),
+ dc_48v_b(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Unique index for the DC power supply channel."
+ ::= { ubiEnvMonSupplyChannelEntry 1 }
+
+
+ ubiEnvMonSupplyChannelState OBJECT-TYPE
+ SYNTAX UbiEnvMonState
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the DC power supply channel
+ being instrumented.
+ Represents the power state of a device being monitored.
+ Valid values are:
+
+ normal(1): the environment is good, such as low
+ temperature.
+
+ notPresent(5): the environmental monitor is not present,
+ such as temperature sensors do not exist.
+
+ notFunctioning(6): the environmental monitor does not
+ function properly.
+ "
+ ::= { ubiEnvMonSupplyChannelEntry 2 }
+
+
+
+
+-- *****************************************************************
+-- ubiEnvMonMIBNotificationEnables
+-- ****************************************************************
+ ubiEnvMonEnableTempStatusChange OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates whether the system
+ produces the ubiEnvMonTempStatusChangeNotif.
+ A false value prevents temperature notifications
+ from being sent by this entity."
+ DEFVAL { false }
+ ::= { ubiEnvMonMIBNotificationEnables 1 }
+
+ ubiEnvMonEnableFanStatusChange OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates whether the system
+ produces the ubiEnvMonFanStatusChangeNotif.
+ A false value prevents fan notifications
+ from being sent by this entity."
+ DEFVAL { false }
+ ::= { ubiEnvMonMIBNotificationEnables 2 }
+
+ ubiEnvMonEnableSupplyStatusChange OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates whether the system
+ produces the ubiEnvMonSuppStatusChangeNotif.
+ A false value prevents redundant supply notifications
+ from being generated by this system."
+ DEFVAL { false }
+ ::= { ubiEnvMonMIBNotificationEnables 3 }
+
+ ubiEnvMonEnableSupplyChannelStatusChange OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This variable indicates whether the system
+ produces the ubiEnvMonSuppExtStatusChangeNotif.
+ A false value prevents redundant supply notifications
+ from being generated by this system."
+ DEFVAL { false }
+ ::= { ubiEnvMonMIBNotificationEnables 4 }
+
+-- *****************************************************************
+-- ubiEnvMonMIBNotificationPrefix
+-- ****************************************************************
+
+
+-- the following two OBJECT IDENTIFIERS are used to define SNMPv2 Notifications
+-- that are backward compatible with SNMPv1 Traps.
+ubiEnvMonMIBNotifications OBJECT IDENTIFIER ::= { ubiEnvMonMIBNotificationPrefix 0 }
+
+
+ ubiEnvMonTempStatusChange NOTIFICATION-TYPE
+ OBJECTS {
+ ubiEnvMonTemperatureDescr,
+ ubiEnvMonTemperatureValue,
+ ubiEnvMonTemperatureState
+ }
+ STATUS current
+ DESCRIPTION
+ "A ubiEnvMonTempStatusChangeNotif is sent if there
+ is change in the state of a device being monitored
+ by ubiEnvMonTemperatureState."
+ ::= { ubiEnvMonMIBNotifications 1 }
+
+ ubiEnvMonFanStatusChange NOTIFICATION-TYPE
+ OBJECTS {
+ ubiEnvMonFanDescr,
+ ubiEnvMonFanState
+ }
+ STATUS current
+ DESCRIPTION
+ "A ubiEnvMonFanStatusChangeNotif is sent if there
+ is change in the state of a device being monitored
+ by ubiEnvMonFanState."
+ ::= { ubiEnvMonMIBNotifications 2 }
+
+ ubiEnvMonSupplyStatusChange NOTIFICATION-TYPE
+ OBJECTS {
+ ubiEnvMonSupplyDescr,
+ ubiEnvMonSupplyState
+ }
+ STATUS current
+ DESCRIPTION
+ "A ubiEnvMonSupplyStatChangeNotif is sent if there
+ is change in the state of a device being monitored
+ by ubiEnvMonSupplyState."
+ ::= { ubiEnvMonMIBNotifications 3 }
+
+ ubiEnvMonSupplyChannelStatusChange NOTIFICATION-TYPE
+ OBJECTS {
+ ubiEnvMonSupplyDescr,
+ ubiEnvMonSupplyChannelType,
+ ubiEnvMonSupplyChannelState
+ }
+ STATUS current
+ DESCRIPTION
+ "A ubiEnvMonSuppExtStatusChangeNotif is sent if there
+ is change in the state of a device being monitored
+ by ubiEnvMonSupplyExtChannelStatus."
+ ::= { ubiEnvMonMIBNotifications 4 }
+
+
+-- *****************************************************************
+-- ubiEnvMonMIBConformance
+-- ****************************************************************
+
+-- conformance information
+ubiEnvMonMIBCompliances OBJECT IDENTIFIER ::= { ubiEnvMonMIBConformance 1 }
+ubiEnvMonMIBGroups OBJECT IDENTIFIER ::= { ubiEnvMonMIBConformance 2 }
+
+
+-- compliance statements
+
+ ubiEnvMonMIBCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for entities which implement
+ the Ubiquoss Environmental Monitor MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ ubiEnvMonMIBGroup,
+ ubiEnvMonMIBNotifGroup
+ }
+ GROUP ubiEnvMonMIBGroup
+ DESCRIPTION
+ "The ubiEnvMonMIBGroup is applicable for implementations which
+ need to get the system environment information."
+
+ GROUP ubiEnvMonMIBNotifGroup
+ DESCRIPTION
+ "The ubiEnvMonMIBNotifGroup must be
+ implemented for system environment that have notification."
+ ::= { ubiEnvMonMIBCompliances 1 }
+
+-- units of conformance
+
+ ubiEnvMonMIBGroup OBJECT-GROUP
+ OBJECTS {
+ ubiEnvMonTemperatureDescr,
+ ubiEnvMonTemperatureValue,
+ ubiEnvMonTemperatureHighThreshold,
+ ubiEnvMonTemperatureLowThreshold,
+ ubiEnvMonTemperatureLastShutdown,
+ ubiEnvMonTemperatureState,
+
+ ubiEnvMonFanDescr,
+ ubiEnvMonFanState,
+
+ ubiEnvMonSupplyDescr,
+ ubiEnvMonSupplyState,
+ ubiEnvMonSupplySource,
+
+ ubiEnvMonSupplyExtChannel,
+ ubiEnvMonSupplyExtChannelState,
+
+ ubiEnvMonEnableTempStatusChangeNotif,
+ ubiEnvMonEnableFanStatusChangeNotif,
+ ubiEnvMonEnableSuppStatusChangeNotif,
+ ubiEnvMonEnableSuppExtStatusChangeNotif
+
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing environmental
+ monitoring capability to a ubi chassis."
+ ::= { ubiEnvMonMIBGroups 1 }
+
+ ubiEnvMonMIBNotifGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ ubiEnvMonTempStatusChangeNotif,
+ ubiEnvMonFanStatusChangeNotif,
+ ubiEnvMonSuppStatusChangeNotif,
+ ubiEnvMonSuppExtStatusChangeNotif
+ }
+ STATUS current
+ DESCRIPTION
+ "A notification group providing notification
+ for environmental monitoring. "
+ ::= { ubiEnvMonMIBGroups 2 }
+
+END
|