diff options
Diffstat (limited to 'MIBS/uhp')
| -rw-r--r-- | MIBS/uhp/UHP-MIB | 1314 |
1 files changed, 1314 insertions, 0 deletions
diff --git a/MIBS/uhp/UHP-MIB b/MIBS/uhp/UHP-MIB new file mode 100644 index 0000000..179deff --- /dev/null +++ b/MIBS/uhp/UHP-MIB @@ -0,0 +1,1314 @@ +UHP-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, IpAddress, Integer32, enterprises, Counter32, Gauge32 + FROM SNMPv2-SMI + DisplayString + FROM SNMPv2-TC; + +uhpV32 MODULE-IDENTITY + LAST-UPDATED "201811021200Z" + ORGANIZATION "UHP Networks" + CONTACT-INFO "www.uhp.net" + DESCRIPTION "UHP terminal MIB" + REVISION "201810251200Z" + DESCRIPTION "UHP terminal MIB" + ::= { uhp 22 } + + + + + + +uhp OBJECT IDENTIFIER ::= { enterprises 8000 } +control OBJECT IDENTIFIER ::= { uhpV32 1 } +demod1 OBJECT IDENTIFIER ::= { uhpV32 2 } +demod2 OBJECT IDENTIFIER ::= { uhpV32 3 } +modulator OBJECT IDENTIFIER ::= { uhpV32 4 } +tdma OBJECT IDENTIFIER ::= { uhpV32 5 } +router OBJECT IDENTIFIER ::= { uhpV32 6 } +shaper OBJECT IDENTIFIER ::= { uhpV32 7 } +system OBJECT IDENTIFIER ::= { uhpV32 8 } +mobile OBJECT IDENTIFIER ::= { uhpV32 9 } + +-- Control + + saveConfig OBJECT-TYPE + SYNTAX INTEGER { + nosave(0), + save0(1), + save1(2), + save2(3), + save3(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Save current profile to EEPROM profile 0-3. + Profile 0 is automativally loaded on restart by default." + ::= { control 1 } + + reboot OBJECT-TYPE + SYNTAX INTEGER { + noreboot(1), + reboot(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Reboot device immediately." + ::= { control 2 } + + command OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Issue a command to command-line interface." + ::= { control 3 } + + configEdit OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Profile or global config editing and viewing + Complex input format, only for manufacturer." + ::= { control 4 } + + profile OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Get current profile or run specified profile (1-8)." + ::= { control 5 } + +-- Demod1 + + lbandSNR1 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Signal to noise ratio at L-band demodulator input + measured in 0.1 dB units." + ::= { demod1 1 } + + lbandOffset1 OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frequency offset value in KHz between PLL frequency and + carrier real frequency." + ::= { demod1 2 } + + inLvl1 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current input level x -10dBm" + ::= { demod1 3 } + + inBytes1 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Demodulator1 traffic in bytes + (indexed by ACM channel)" + ::= { demod1 4 } + +-- Demod2 + + lbandSNR2 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Signal to noise ratio at L-band demodulator input + measured in 0.1 dB units." + ::= { demod2 1 } + + lbandOffset2 OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frequency offset value in KHz between PLL frequency and + carrier real frequency." + ::= { demod2 2 } + + inLvl2 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current input level x -10dBm" + ::= { demod2 3 } + + inBytes2 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Demodulator2 traffic in bytes + (indexed by ACM channel)" + ::= { demod2 4 } + +-- Modulator +prioAll OBJECT IDENTIFIER ::= { modulator 1 } + outBytesA OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator traffic in bytes + (indexed by ACM channel)" + ::= { prioAll 1 } + + outPktsA OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator traffic in packets + (indexed by ACM channel)" + ::= { prioAll 2 } + + dropsA OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator dropped packets + (indexed by ACM channel)" + ::= { prioAll 3 } + + queueLenBA OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator queue length in bytes + (indexed by ACM channel)" + ::= { prioAll 4 } + + queueLenPA OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator queue length in packets + (indexed by ACM channel)" + ::= { prioAll 5 } + + numStations OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of stations per ACM channel + (indexed by ACM channel)" + ::= { prioAll 6 } + +prioP1 OBJECT IDENTIFIER ::= { modulator 2 } + + outBytesP1 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P1(Low) priority traffic in bytes + (indexed by ACM channel)" + ::= { prioP1 1 } + outPktsP1 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P1(Low) priority traffic in packets + (indexed by ACM channel)" + ::= { prioP1 2 } + dropsP1 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P1(Low) priority dropped packets + (indexed by ACM channel)" + ::= { prioP1 3 } + queueLenBP1 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P1(Low) priority queue length in bytes + (indexed by ACM channel)" + ::= { prioP1 4 } + queueLenPP1 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P1(Low) priority queue length in packets + (indexed by ACM channel)" + ::= { prioP1 5 } + +prioP4 OBJECT IDENTIFIER ::= { modulator 3 } + + outBytesP4 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P4(Med) priority traffic in bytes + (indexed by ACM channel)" + ::= { prioP4 1 } + outPktsP4 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P4(Med) priority traffic in packets + (indexed by ACM channel)" + ::= { prioP4 2 } + dropsP4 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P4(Med) priority dropped packets + (indexed by ACM channel)" + ::= { prioP4 3 } + queueLenBP4 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P4(Med) priority queue length in bytes + (indexed by ACM channel)" + ::= { prioP4 4 } + queueLenPP4 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P4(Med) priority queue length in packets + (indexed by ACM channel)" + ::= { prioP4 5 } + +prioP7 OBJECT IDENTIFIER ::= { modulator 4 } + + outBytesP7 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P7(High) priority traffic in bytes + (indexed by ACM channel)" + ::= { prioP7 1 } + outPktsP7 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P7(High) priority traffic in packets + (indexed by ACM channel)" + ::= { prioP7 2 } + dropsP7 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P7(High) priority dropped packets + (indexed by ACM channel)" + ::= { prioP7 3 } + queueLenBP7 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P7(High) priority queue length in bytes + (indexed by ACM channel)" + ::= { prioP7 4 } + queueLenPP7 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P7(High) priority queue length in packets + (indexed by ACM channel)" + ::= { prioP7 5 } + +prioCtrl OBJECT IDENTIFIER ::= { modulator 5 } + + outBytesC OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator control traffic in bytes + (index 1 only)" + ::= { prioCtrl 1 } + outPktsC OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator control traffic in packets + (index 1 only)" + ::= { prioCtrl 2 } + +level OBJECT IDENTIFIER ::= { modulator 6 } + + txLevel OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current TX level x -10dBm" + ::= { level 1 } + + txLevelDelta OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current TX level delta from set level x -10dBm" + ::= { level 2 } + + txMaxLevel OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Max TLC level x -10dBm" + ::= { level 3 } + +prioP2 OBJECT IDENTIFIER ::= { modulator 7 } + + outBytesP2 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P2 priority traffic in bytes + (indexed by ACM channel)" + ::= { prioP2 1 } + outPktsP2 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P2 priority traffic in packets + (indexed by ACM channel)" + ::= { prioP2 2 } + dropsP2 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P2 priority dropped packets + (indexed by ACM channel)" + ::= { prioP2 3 } + queueLenBP2 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P2 priority queue length in bytes + (indexed by ACM channel)" + ::= { prioP2 4 } + queueLenPP2 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P2 priority queue length in packets + (indexed by ACM channel)" + ::= { prioP2 5 } + +prioP3 OBJECT IDENTIFIER ::= { modulator 8 } + + outBytesP3 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P3 priority traffic in bytes + (indexed by ACM channel)" + ::= { prioP3 1 } + outPktsP3 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P3 priority traffic in packets + (indexed by ACM channel)" + ::= { prioP3 2 } + dropsP3 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P3 priority dropped packets + (indexed by ACM channel)" + ::= { prioP3 3 } + queueLenBP3 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P3 priority queue length in bytes + (indexed by ACM channel)" + ::= { prioP3 4 } + queueLenPP3 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P3 priority queue length in packets + (indexed by ACM channel)" + ::= { prioP3 5 } + +prioP5 OBJECT IDENTIFIER ::= { modulator 9 } + + outBytesP5 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P5 priority traffic in bytes + (indexed by ACM channel)" + ::= { prioP5 1 } + outPktsP5 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P5 priority traffic in packets + (indexed by ACM channel)" + ::= { prioP5 2 } + dropsP5 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P5 priority dropped packets + (indexed by ACM channel)" + ::= { prioP5 3 } + queueLenBP5 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P5 priority queue length in bytes + (indexed by ACM channel)" + ::= { prioP5 4 } + queueLenPP5 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P5 priority queue length in packets + (indexed by ACM channel)" + ::= { prioP5 5 } + +prioP6 OBJECT IDENTIFIER ::= { modulator 10 } + + outBytesP6 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P6 priority traffic in bytes + (indexed by ACM channel)" + ::= { prioP6 1 } + outPktsP6 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P6 priority traffic in packets + (indexed by ACM channel)" + ::= { prioP6 2 } + dropsP6 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P6 priority dropped packets + (indexed by ACM channel)" + ::= { prioP6 3 } + queueLenBP6 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P6 priority queue length in bytes + (indexed by ACM channel)" + ::= { prioP6 4 } + queueLenPP6 OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Modulator P6 priority queue length in packets + (indexed by ACM channel)" + ::= { prioP6 5 } + +-- Router + + unroutedPkts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of packets, router couldn't route anywhere + (though they could have been tunneled)." + ::= { router 1 } + + unroutedSource OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Last source IP address of unrouted packet." + ::= { router 2 } + + unroutedDest OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Last destination IP address of unrouted packet." + ::= { router 3 } + + outVlanBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of bytes, transmitted via VLAN. + Requires index, which is VLAN number." + ::= { router 4 } + + inVlanBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of bytes, received via VLAN. + Requires index, which is VLAN number." + ::= { router 5 } + + outSvlanBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of bytes, transmitted via SVLAN. + Requires index, which is SVLAN number." + ::= { router 6 } + + inSvlanBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of bytes, received via SVLAN. + Requires index, which is SVLAN number." + ::= { router 7 } + + inSvlanPackets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of packets, received via SVLAN. + Requires index, which is SVLAN number." + ::= { router 8 } + +-- TDMA + +tts OBJECT IDENTIFIER ::= { tdma 1 } +inroute OBJECT IDENTIFIER ::= { tdma 2 } +server OBJECT IDENTIFIER ::= { tdma 3 } +remTable OBJECT IDENTIFIER ::= { tdma 4 } +station OBJECT IDENTIFIER ::= { tdma 5 } + +-- TTS + + tdelta OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "HUB/Outroute - TTS value + Inroute/remote - Timers delta between local station and hub + In 10MHz ticks. + Developers only" + ::= { tts 1 } + + tdtConfidence OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "HUB/Outroute - TTS confidence value 0-64 + Inroute/remote - Tdelta confidence 0-64" + ::= { tts 2 } + + softErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of soft errors of TTS/Tdelta measurement algorithm. + Soft errors mean current value is outside averaged window." + ::= { tts 3 } + + hardErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of hard errors of TTS/Tdelta measurement algorithm." + ::= { tts 4 } + + + hubTTS OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "HUB TTS value in 10MHz ticks" + ::= { tts 5 } + + hubTTSconfidence OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "HUB TTS confidence value 0-64. It is requested from remotes or inroutes" + ::= { tts 6 } + + remoteTTS OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Remote TTS value with compensations in 10MHz ticks. Developers only" + ::= { tts 7 } + +-- Inroute + + netState OBJECT-TYPE + SYNTAX INTEGER { + off(0), + init(1), + noConfig(2), + useConfig(3), + redundant(4), + startRX(5), + cotmPointing(6), + startHubTX(7), + noRX(8), + identify(9), + getNetConfig(10), + calcDelays(11), + startTDMA(12), + startTX(13), + acquisition(14), + adjustment(15), + noStations(16), + operation(17) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Operation sequence level" + ::= { inroute 1 } + + frameDelay OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Delay in frames between TX and RX processing. Developers only" + ::= { inroute 2 } + + sectionBW OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Bandwidth in Bits/second of single slot in frame" + ::= { inroute 3 } + + netRequest OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Sum of all requests of all stations (slots)" + ::= { inroute 4 } + + freeSlots OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of free-allocated slots in current frame" + ::= { inroute 5 } + + netLoad OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Network load in % (values, greater than 100% mean overload)" + ::= { inroute 6 } + +-- Server + + serverStatus OBJECT-TYPE + SYNTAX INTEGER { + off(0), + init(1), + noConfig(2), + useConfig(3), + redundant(4), + startRX(5), + cotmPointing(6), + startHubTX(7), + noRX(8), + identify(9), + getNetConfig(10), + calcDelays(11), + startTDMA(12), + startTX(13), + acquisition(14), + adjustment(15), + noStations(16), + operation(17) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Server reply status" + ::= { server 1 } + + frameDuration OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frame duration in 10M ticks" + ::= { server 2 } + +-- Remotes statistics table ( No SNMP_NEXT, direct remotes 1-252 addressing by index) + + rxBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Summary number of bytes, received from this remote" + ::= { remTable 1 } + + p1Bytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of P1(Low) priority bytes, received from this remote" + ::= { remTable 2 } + + p4Bytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of P4(Med) priority bytes, received from this remote" + ::= { remTable 3 } + + p7Bytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of P7(High) priority bytes, received from this remote" + ::= { remTable 4 } + + crcErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of CRC errors, during reception of this remote" + ::= { remTable 5 } + + carrierToNoise OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Receive carrier-to-noise ratio of this remote in 0.1 dB steps" + ::= { remTable 6 } + + freqOffset OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Receive Frequency offset of this remote in Hz" + ::= { remTable 7 } + + remRecvHub OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "How this remote receives the hub in 0.1 dB steps" + ::= { remTable 8 } + + linkState OBJECT-TYPE + SYNTAX INTEGER { + up(1), + down(2), + off(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Link state of this remote" + ::= { remTable 9 } + + lastHeard OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Time in seconds since last burst was received from remote. Developers only" + ::= { remTable 10 } + + downTimes OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "How many times remote changed state to DOWN" + ::= { remTable 11 } + + totalRequest OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current non-real-time + real-time request from remote" + ::= { remTable 12 } + + nrtRequest OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current non-real-time request from remote" + ::= { remTable 13 } + + rtmRequest OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current real-time request from remote" + ::= { remTable 14 } + + currentFP OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of sections, allocated in current frame plan for remote" + ::= { remTable 15 } + + txLvl OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current transmit level x -0.1 dBm (1:360 -> -0.1:-36 dBm)" + ::= { remTable 16 } + + faults OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Station faults bitmap: 1-service monitoring local warning (LWRN);2-service monitoring local alarm (LFLT);4-service monitoring network warning (NWRN);8-service monitoring network alarm (NFLT);0x10 system fault (SYST);0x20 reboot fault (REBT);0x40 LAN down (LAN);0x80 RX offset fault (OFFS);0x100 CRC errors (CRC);0x200 TLC fault (TLC)" + ::= { remTable 17 } + + p2Bytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of P2 priority bytes, received from this remote" + ::= { remTable 18 } + + p3Bytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of P3 priority bytes, received from this remote" + ::= { remTable 19 } + + p5Bytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of P5 priority bytes, received from this remote" + ::= { remTable 20 } + + p6Bytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of P6 priority bytes, received from this remote" + ::= { remTable 21 } + + +-- Station data + + stationState OBJECT-TYPE + SYNTAX INTEGER { + off(0), + init(1), + noConfig(2), + useConfig(3), + redundant(4), + startRX(5), + cotmPointing(6), + startHubTX(7), + noRX(8), + identify(9), + getNetConfig(10), + calcDelays(11), + startTDMA(12), + startTX(13), + acquisition(14), + adjustment(15), + noStations(16), + operation(17) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Remote initialization sequence level" + ::= { station 1 } + + remnrtRequest OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Request for non-real-time bandwidth in sections" + ::= { station 2 } + + remrtRequest OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Request for real-time bandwidth in sections" + ::= { station 3 } + + fpLost OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Lost frame plans number" + ::= { station 4 } + + lvlOffset OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Offset between reference level and C/N level on hub. Developers only" + ::= { station 5 } + + lvlAdjust OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TX power level adjustment value in 0.1 dB steps" + ::= { station 6 } + + frqOffset OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Frequency offset on hub. Developers only" + ::= { station 7 } + + frqAdjust OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TX frequency adjustment value in Hz. Developers only" + ::= { station 8 } + + timeOffset OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Timing offset on hub in symbols" + ::= { station 9 } + + timeAdjust OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "TX timing adjustment value in 10M ticks" + ::= { station 10 } + +-- Traffic Shaper stats ( No SNMP_NEXT, direct stream 0-500 addressing by index) + + streamSpeed OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current speed in Kbits per second of current stream" + ::= { shaper 1 } + + streamP1Speed OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current speed in Kbits per second of P1(Low) priority sub-stream" + ::= { shaper 2 } + + streamP4Speed OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current speed in Kbits per second of P4(Med) priority sub-stream" + ::= { shaper 3 } + + streamP7Speed OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current speed in Kbits per second of P7(High) priority sub-stream" + ::= { shaper 4 } + + streamDelay OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current packets delay in stream x 0.1s" + ::= { shaper 5 } + + streamQueue OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current stream queue length in bytes" + ::= { shaper 6 } + + streamP2Speed OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current speed in Kbits per second of P2 priority sub-stream" + ::= { shaper 7 } + + streamP3Speed OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current speed in Kbits per second of P3 priority sub-stream" + ::= { shaper 8 } + + streamP5Speed OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current speed in Kbits per second of P5 priority sub-stream" + ::= { shaper 9 } + + streamP6Speed OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current speed in Kbits per second of P6 priority sub-stream" + ::= { shaper 10 } + +-- System stats + + temperature OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current temperature" + ::= { system 1 } + + cpuLoad OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current CPU load in percent" + ::= { system 2 } + + buffers OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current buffers usage in percent" + ::= { system 3 } + + redundancy OBJECT-TYPE + SYNTAX INTEGER { + idle(0), + backup(1), + faults(2), + trying(3), + active(4), + off(5) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Current redundancy state" + ::= { system 4 } + + swVersion OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Software version. Four numbers of version contained in four bytes + in order of precedence (see as hexadecimal)." + ::= { system 5 } + + releaseDate OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Release date. Two low bytes of number contain year, + then month and day (see as hexadecimal)." + ::= { system 6 } + +-- Mobile + + version OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Software (protocol) version. Number 10 means V1.0" + ::= { mobile 1 } + + serialNumber OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Serial number of this unit. If printed on the screen should be + printed as hexadecimal! Example - 4660 returned should be printed + as 1234 in hex." + ::= { mobile 2 } + + inputLevel OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Input baseband RF level in -0.1dBm steps. 500 means -50 dBm. + Higher value means lower level. 800 (-80dBm) means no signal." + ::= { mobile 3 } + + + rxState OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Composite value to provide controller with receive and overall state. + 0 means no RX lock. + 1 means absence of coordinates (send location data). + 2 means absence of TX status (send TX control command). + 3-250 means RX lock and shows demodulator C/N level in 0.1dBm + steps (e.g. 100 means C/N=10 dB). + Actual in all modes of operation. In SCPC/Star modes shows + SCPC demodulator level, in FullMesh mode burst demodulator level." + ::= { mobile 4 } + + + searchState OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "GET + Value in percent (0-100) of current carrier search sequence. + As search for narrow (<1Msps) carrier with high offset (DRO + LNB) can last up-to 30 seconds, controller can wait until + the whole acquisition bandwidth is scanned at least once. + SET + Writing any value restarts search cycle." + ::= { mobile 5 } + + txControl OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "GET + Current TX status (0-off, 1-on). + SET + Writing 0 turns TX off, 1 - turns on." + ::= { mobile 6 } + + location OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "GET + Not applicable. + SET + NMEA RMC string + $GPRMC,hhmmss.ss,A,GGMM.MM,P,gggmm.mm,J,v.v,b.b,ddmmyy,x.x,n,m*hh<CR><LF> + Location should be re-supplied if changed more than 1 minute by any coordinate." + ::= { mobile 7 } + +END
\ No newline at end of file |