+WebGraph-Thermo-Hygrometer-US-MIB DEFINITIONS ::= BEGIN
+----------------------------------------------------------------
+-- Revison: 1.39
+----------------------------------------------------------------
+-- 28.06.2018 New:
+-- syntax error corrected
+----------------------------------------------------------------
+
+-- 12.12.2017 New:
+-- wtWebGraphThermoHygroMQTTLastWillEnable
+-- wtWebGraphThermoHygroMQTTLastWillTopic
+-- wtWebGraphThermoHygroMQTTLastWillMsg
+-- wtWebGraphThermoHygroMQTTLastWillQoS
+-- wtWebGraphThermoHygroMQTTLastWillRetain
+-- wtWebGraphThermoHygroMQTTLastWillConnectEnable
+-- wtWebGraphThermoHygroMQTTLastWillConnectMsg
+----------------------------------------------------------------
+-- Revison: 1.37
+----------------------------------------------------------------
+-- 07.09.2017 New: wtWebioAnxGraphAlarmManagerPort
+-- wtWebioAnxGraphAlarmMQTT_QoS
+-- wtWebioAnxGraphAlarmMQTT_Retain
+----------------------------------------------------------------
+-- Revison: 1.36
+----------------------------------------------------------------
+-- 09.03.2017 New: wtWebGraphThermoHygroAlarmSensorLostSelection
+-- wtWebGraphThermoHygroAlarmLimitWindow
+----------------------------------------------------------------
+-- Revison: 1.35
+----------------------------------------------------------------
+-- 09.11.2016 New: wtWebGraphThermoHygroMQTT group
+-- HTTP Request, MQTT Alarm, REST
+----------------------------------------------------------------
+-- Revison: 1.34
+----------------------------------------------------------------
+-- 15.07.2015 Changes for new Navigation (__JB__)
+----------------------------------------------------------------
+-- Revison: 1.33
+----------------------------------------------------------------
+-- 28.05.14 New Language Select
+--
+----------------------------------------------------------------
+-- Revison: 1.32
+----------------------------------------------------------------
+-- 11.12.13 Initial Setup
+--
+
+
+
+ IMPORTS
+
+ OBJECT-TYPE FROM RFC-1212
+ TRAP-TYPE FROM RFC-1215
+ DisplayString, PhysAddress FROM RFC1213-MIB
+ enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI;
+
+
+-- IpAddress ::=
+-- [APPLICATION 0]
+-- IMPLICIT OCTET STRING (SIZE (4))
+-- Counter ::=
+-- [APPLICATION 1]
+-- IMPLICIT INTEGER (0..4294967295)
+-- Gauge ::=
+-- [APPLICATION 2]
+-- IMPLICIT INTEGER (0..4294967295)
+-- TimeTicks ::=
+-- [APPLICATION 3]
+-- IMPLICIT INTEGER (0..4294967295)
+
+
+-- DisplayString ::= OCTET STRING
+-- PhysAddress ::= OCTET STRING
+
+-- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 }
+-- privat OBJECT IDENTIFIER ::= { internet 4 }
+-- enterprises OBJECT IDENTIFIER ::= { privat 1 }
+
+
+
+-- Wiesemann & Theis Com-Server MIB
+
+ wut OBJECT IDENTIFIER ::= { enterprises 5040 }
+ wtComServer OBJECT IDENTIFIER ::= { wut 1 }
+ wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 }
+
+-- wtWebGraph Tree
+
+ wtWebGraphThermoHygro OBJECT IDENTIFIER ::= { wtWebio 42 }
+
+-- wtWebGraphThermoHygro Tree
+
+ wtWebGraphThermoHygroTemp OBJECT IDENTIFIER ::= { wtWebGraphThermoHygro 1 }
+ wtWebGraphThermoHygroSessCntrl OBJECT IDENTIFIER ::= { wtWebGraphThermoHygro 2 }
+ wtWebGraphThermoHygroConfig OBJECT IDENTIFIER ::= { wtWebGraphThermoHygro 3 }
+ wtWebGraphThermoHygroDiag OBJECT IDENTIFIER ::= { wtWebGraphThermoHygro 4 }
+
+-- wtWebGraphThermoHygroConfig Tree
+
+ wtWebGraphThermoHygroDevice OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroConfig 1 }
+ wtWebGraphThermoHygroPorts OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroConfig 2 }
+ wtWebGraphThermoHygroManufact OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroConfig 3 }
+
+-- wtWebGraphThermoHygroDevice Tree
+
+ wtWebGraphThermoHygroText OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 1 }
+ wtWebGraphThermoHygroTimeDate OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 2 }
+ wtWebGraphThermoHygroBasic OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 3 }
+ wtWebGraphThermoHygroDatalogger OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 4 }
+ wtWebGraphThermoHygroAlarm OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 5 }
+ wtWebGraphThermoHygroGraphics OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 6 }
+
+-- wtWebGraphThermoHygroTimeDate Tree
+
+ wtWebGraphThermoHygroTimeZone OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroTimeDate 1 }
+ wtWebGraphThermoHygroTimeServer OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroTimeDate 2 }
+ wtWebGraphThermoHygroDeviceClock OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroTimeDate 3 }
+
+-- wtWebGraphThermoHygroBasic Tree
+
+ wtWebGraphThermoHygroNetwork OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 1 }
+ wtWebGraphThermoHygroHTTP OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 2 }
+ wtWebGraphThermoHygroMail OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 3 }
+ wtWebGraphThermoHygroSNMP OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 4 }
+ wtWebGraphThermoHygroUDP OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 5 }
+ wtWebGraphThermoHygroSyslog OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 6 }
+ wtWebGraphThermoHygroFTP OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 7 }
+ wtWebGraphThermoHygroRSS OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 8 }
+ wtWebGraphThermoHygroLanguage OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 9 }
+ wtWebGraphThermoHygroMQTT OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 12 }
+ wtWebGraphThermoHygroREST OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 13 }
+
+
+-- wtWebGraphThermoHygroGraphics Tree
+
+ wtWebGraphThermoHygroGraphicsBase OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroGraphics 1 }
+ wtWebGraphThermoHygroGraphicsSelect OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroGraphics 2 }
+ wtWebGraphThermoHygroGraphicsScale OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroGraphics 3 }
+
+-- wtWebGraphThermoHygroTemp Group
+------------------------
+
+wtWebGraphThermoHygroSensors OBJECT-TYPE
+ SYNTAX INTEGER (1..2)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Number of sensors"
+ ::= { wtWebGraphThermoHygroTemp 1 }
+
+-- Interface Table
+
+wtWebGraphThermoHygroSensorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WtWebGraphThermoHygroSensorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "List of sensors."
+ ::= { wtWebGraphThermoHygroTemp 2 }
+
+wtWebGraphThermoHygroSensorEntry OBJECT-TYPE
+ SYNTAX WtWebGraphThermoHygroSensorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "List of sensor numbers."
+ INDEX { wtWebGraphThermoHygroSensorNo }
+ ::= { wtWebGraphThermoHygroSensorTable 1 }
+
+WtWebGraphThermoHygroSensorEntry ::= SEQUENCE {
+ wtWebGraphThermoHygroSensorNo INTEGER
+}
+
+wtWebGraphThermoHygroSensorNo OBJECT-TYPE
+ SYNTAX INTEGER (1..2)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Sensor number."
+ ::= { wtWebGraphThermoHygroSensorEntry 1 }
+
+
+-- wtWebGraphThermoHygroTempValue Table
+
+wtWebGraphThermoHygroTempValueTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WtWebGraphThermoHygroTempValueEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "List of measurement values corresponding to the channel numbers."
+ ::= { wtWebGraphThermoHygroTemp 3 }
+
+wtWebGraphThermoHygroTempValueEntry OBJECT-TYPE
+ SYNTAX WtWebGraphThermoHygroTempValueEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Measurement values of the sensors."
+ INDEX { wtWebGraphThermoHygroSensorNo }
+ ::= { wtWebGraphThermoHygroTempValueTable 1 }
+
+WtWebGraphThermoHygroTempValueEntry ::= SEQUENCE{
+ wtWebGraphThermoHygroTempValue OCTET STRING
+}
+
+wtWebGraphThermoHygroTempValue OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (5))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Measurement value of the sensor, ASCII, 5 characters in length."
+ ::= { wtWebGraphThermoHygroTempValueEntry 1 }
+
+-- wtWebGraphThermoHygroBinaryTempValue Table
+
+wtWebGraphThermoHygroBinaryTempValueTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WtWebGraphThermoHygroBinaryTempValueEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "List of binary measurement values corresponding to the channel numbers."
+ ::= { wtWebGraphThermoHygroTemp 4 }
+
+wtWebGraphThermoHygroBinaryTempValueEntry OBJECT-TYPE
+ SYNTAX WtWebGraphThermoHygroBinaryTempValueEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Binary measurement values of the sensors."
+ INDEX { wtWebGraphThermoHygroSensorNo }
+ ::= { wtWebGraphThermoHygroBinaryTempValueTable 1 }
+
+WtWebGraphThermoHygroBinaryTempValueEntry ::= SEQUENCE{
+ wtWebGraphThermoHygroBinaryTempValue INTEGER
+}
+
+wtWebGraphThermoHygroBinaryTempValue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Binary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent,
+ signed number, 0x4FFF6 indicates an
+ invalid measured value."
+ ::= { wtWebGraphThermoHygroBinaryTempValueEntry 1 }
+
+-- wtWebGraphThermoHygroTempValuePkt Table
+
+wtWebGraphThermoHygroTempValuePktTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WtWebGraphThermoHygroTempValuePktEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "List of measurement values corresponding to the channel numbers."
+ ::= { wtWebGraphThermoHygroTemp 8 }
+
+wtWebGraphThermoHygroTempValuePktEntry OBJECT-TYPE
+ SYNTAX WtWebGraphThermoHygroTempValuePktEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Measurement values of the sensors."
+ INDEX { wtWebGraphThermoHygroSensorNo }
+ ::= { wtWebGraphThermoHygroTempValuePktTable 1 }
+
+WtWebGraphThermoHygroTempValuePktEntry ::= SEQUENCE{
+ wtWebGraphThermoHygroTempValuePkt OCTET STRING
+}
+
+wtWebGraphThermoHygroTempValuePkt OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (5))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Measurement value of the sensor, ASCII, 5 characters in length, delimeter is decimal point."
+ ::= { wtWebGraphThermoHygroTempValuePktEntry 1 }
+
+-- wtWebGraphThermoHygroSessCntrl Group
+--------------------------------
+
+wtWebGraphThermoHygroSessCntrlPassword OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Entering this password opens a session which is ended by writing a 1 to
+ wtWebGraphThermoHygroSessCntrlLogout. When read this variable provides a string of
+ length zero."
+ ::= { wtWebGraphThermoHygroSessCntrl 1 }
+
+wtWebGraphThermoHygroSessCntrlConfigMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermoHygroSessCntrl-NoSession(0),
+ wtWebGraphThermoHygroSessCntrl-Session(1)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When the device is in SNMP configuration mode, the value 1 is
+ returned, otherwise 0. If the read value is 0 even though the
+ password was written, the device is already in config mode and the
+ variables can only be read."
+ ::= { wtWebGraphThermoHygroSessCntrl 2 }
+
+wtWebGraphThermoHygroSessCntrlLogout OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "If the device is in configuration mode and the session was opened by
+ this SNMP Manager, writing a 1 to this variable will end the session
+ and all parameters are stored.
+ Writing a 2 discards all entries again.
+ When read this variable provides the value 0."
+ ::= { wtWebGraphThermoHygroSessCntrl 3 }
+
+wtWebGraphThermoHygroSessCntrlAdminPassword OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This password protects access to the variables with administrator rights.
+ It can only be changed by the administrator. If no password was assigned,
+ the valid password is public."
+ ::= { wtWebGraphThermoHygroSessCntrl 4 }
+
+wtWebGraphThermoHygroSessCntrlConfigPassword OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This password protects access to the variables with configurator rights. It can
+ be changed by the administrator and by the configurator. If no password was assigned,
+ the valid password is public. When read this variable provides a null-pointer."
+ ::= { wtWebGraphThermoHygroSessCntrl 5 }
+
+
+-- wtWebGraphThermoHygroText Group
+------------------------
+
+wtWebGraphThermoHygroDeviceName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name of the Webio, which is user definable."
+ ::= { wtWebGraphThermoHygroText 1 }
+
+wtWebGraphThermoHygroDeviceText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Description of the Webio, which is user definable."
+ ::= { wtWebGraphThermoHygroText 2 }
+
+wtWebGraphThermoHygroDeviceLocation OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Description of the location of the Webio, which is user definable."
+ ::= { wtWebGraphThermoHygroText 3 }
+
+wtWebGraphThermoHygroDeviceContact OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Contact address of the system operator of the Webio, which is user definable."
+ ::= { wtWebGraphThermoHygroText 4 }
+
+-- wtWebGraphThermoHygroTimeZone Group
+----------------------------
+
+wtWebGraphThermoHygroTzOffsetHrs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset hours for the time zone (winter time) with respect to UTC."
+ ::= { wtWebGraphThermoHygroTimeZone 1 }
+
+wtWebGraphThermoHygroTzOffsetMin OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset minutes for the time zone (winter time) with respect to UTC."
+ ::= { wtWebGraphThermoHygroTimeZone 2 }
+
+wtWebGraphThermoHygroTzEnable OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded conditions:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1-7: unused
+ Bit 0 : Apply Timezone"
+ ::= { wtWebGraphThermoHygroTimeZone 3 }
+
+wtWebGraphThermoHygroStTzOffsetHrs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset hours of the time zone (summer time) with respect to UTC."
+ ::= { wtWebGraphThermoHygroTimeZone 4 }
+
+wtWebGraphThermoHygroStTzOffsetMin OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset minutes of the time zone (summer time) with respect to UTC."
+ ::= { wtWebGraphThermoHygroTimeZone 5 }
+
+wtWebGraphThermoHygroStTzEnable OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded conditions:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1-7: unused
+ Bit 0 : Apply Summertime"
+ ::= { wtWebGraphThermoHygroTimeZone 6 }
+
+wtWebGraphThermoHygroStTzStartMonth OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermoHygroStartMonth-January(1),
+ wtWebGraphThermoHygroStartMonth-February(2),
+ wtWebGraphThermoHygroStartMonth-March(3),
+ wtWebGraphThermoHygroStartMonth-April(4),
+ wtWebGraphThermoHygroStartMonth-May(5),
+ wtWebGraphThermoHygroStartMonth-June(6),
+ wtWebGraphThermoHygroStartMonth-July(7),
+ wtWebGraphThermoHygroStartMonth-August(8),
+ wtWebGraphThermoHygroStartMonth-September(9),
+ wtWebGraphThermoHygroStartMonth-October(10),
+ wtWebGraphThermoHygroStartMonth-November(11),
+ wtWebGraphThermoHygroStartMonth-December(12)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Month in which the change is made from winter time to summer time."
+ ::= { wtWebGraphThermoHygroTimeZone 7 }
+
+wtWebGraphThermoHygroStTzStartMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermoHygroStartMode-first(1),
+ wtWebGraphThermoHygroStartMode-second(2),
+ wtWebGraphThermoHygroStartMode-third(3),
+ wtWebGraphThermoHygroStartMode-fourth(4),
+ wtWebGraphThermoHygroStartMode-last(5)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Mode of the day of the week for which the change is made from winter time to summer time."
+ ::= { wtWebGraphThermoHygroTimeZone 8 }
+
+wtWebGraphThermoHygroStTzStartWday OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermoHygroStartWday-Sunday(1),
+ wtWebGraphThermoHygroStartWday-Monday(2),
+ wtWebGraphThermoHygroStartWday-Tuesday(3),
+ wtWebGraphThermoHygroStartWday-Thursday(4),
+ wtWebGraphThermoHygroStartWday-Wednesday(5),
+ wtWebGraphThermoHygroStartWday-Friday(6),
+ wtWebGraphThermoHygroStartWday-Saturday(7)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Day of the week on which the change is made from winter time to summer time"
+ ::= { wtWebGraphThermoHygroTimeZone 9 }
+
+wtWebGraphThermoHygroStTzStartHrs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Hour in which the time zone is changed from winter to summer time with
+ respect to UTC."
+ ::= { wtWebGraphThermoHygroTimeZone 10 }
+
+wtWebGraphThermoHygroStTzStartMin OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Minute in which the time zone is changed from winter to summer time with
+ respect to UTC."
+ ::= { wtWebGraphThermoHygroTimeZone 11 }
+
+wtWebGraphThermoHygroStTzStopMonth OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermoHygroStopMonth-January(1),
+ wtWebGraphThermoHygroStopMonth-February(2),
+ wtWebGraphThermoHygroStopMonth-March(3),
+ wtWebGraphThermoHygroStopMonth-April(4),
+ wtWebGraphThermoHygroStopMonth-May(5),
+ wtWebGraphThermoHygroStopMonth-June(6),
+ wtWebGraphThermoHygroStopMonth-July(7),
+ wtWebGraphThermoHygroStopMonth-August(8),
+ wtWebGraphThermoHygroStopMonth-September(9),
+ wtWebGraphThermoHygroStopMonth-October(10),
+ wtWebGraphThermoHygroStopMonth-November(11),
+ wtWebGraphThermoHygroStopMonth-December(12)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Month in which the change is made from summer time to winter time."
+ ::= { wtWebGraphThermoHygroTimeZone 12 }
+
+wtWebGraphThermoHygroStTzStopMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermoHygroStopMode-first(1),
+ wtWebGraphThermoHygroStopMode-second(2),
+ wtWebGraphThermoHygroStopMode-third(3),
+ wtWebGraphThermoHygroStopMode-fourth(4),
+ wtWebGraphThermoHygroStopMode-last(5)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Mode of the week day on which the change is made from summer time to winter time."
+ ::= { wtWebGraphThermoHygroTimeZone 13 }
+
+wtWebGraphThermoHygroStTzStopWday OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermoHygroStopWday-Sunday(1),
+ wtWebGraphThermoHygroStopWday-Monday(2),
+ wtWebGraphThermoHygroStopWday-Tuesday(3),
+ wtWebGraphThermoHygroStopWday-Thursday(4),
+ wtWebGraphThermoHygroStopWday-Wednesday(5),
+ wtWebGraphThermoHygroStopWday-Friday(6),
+ wtWebGraphThermoHygroStopWday-Saturday(7)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Day of the week on which the change is made from summer time to winter time."
+ ::= { wtWebGraphThermoHygroTimeZone 14 }
+
+wtWebGraphThermoHygroStTzStopHrs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Hour at which the time zone is changed from summer to winter time with
+ respect to UTC."
+ ::= { wtWebGraphThermoHygroTimeZone 15 }
+
+wtWebGraphThermoHygroStTzStopMin OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Minute at which the time zone is changed from summer to winter time with
+ respect to UTC."
+ ::= { wtWebGraphThermoHygroTimeZone 16 }
+
+-- wtWebGraphThermoHygroTimeServer Group
+----------------------------
+
+wtWebGraphThermoHygroTimeServer1 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "IP address or name of the 1st time server in ASCII"
+ ::= { wtWebGraphThermoHygroTimeServer 1 }
+
+wtWebGraphThermoHygroTimeServer2 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "IP address or name of the 2nd time server in ASCII"
+ ::= { wtWebGraphThermoHygroTimeServer 2 }
+
+wtWebGraphThermoHygroTsEnable OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded conditions:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1-7: unused
+ Bit 0 : Apply Time Server"
+ ::= { wtWebGraphThermoHygroTimeServer 3 }
+
+wtWebGraphThermoHygroTsSyncTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Daily synchronisation time with the time server (hour: 0-23)."
+ ::= { wtWebGraphThermoHygroTimeServer 4 }
+
+-- wtWebGraphThermoHygroDeviceClock Group
+----------------------------
+
+wtWebGraphThermoHygroClockHrs OBJECT-TYPE
+ SYNTAX INTEGER (0..23)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Clock hours taking into account the time zone settings."
+ ::= { wtWebGraphThermoHygroDeviceClock 1 }
+
+wtWebGraphThermoHygroClockMin OBJECT-TYPE
+ SYNTAX INTEGER (0..59)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Clock minutes taking into account the time zone settings."
+ ::= { wtWebGraphThermoHygroDeviceClock 2 }
+
+wtWebGraphThermoHygroClockDay OBJECT-TYPE
+ SYNTAX INTEGER (1..31)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Date: Day of the month, taking into account the time zone settings."
+ ::= { wtWebGraphThermoHygroDeviceClock 3 }
+
+wtWebGraphThermoHygroClockMonth OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermoHygroClockMonth-January(1),
+ wtWebGraphThermoHygroClockMonth-February(2),
+ wtWebGraphThermoHygroClockMonth-March(3),
+ wtWebGraphThermoHygroClockMonth-April(4),
+ wtWebGraphThermoHygroClockMonth-May(5),
+ wtWebGraphThermoHygroClockMonth-June(6),
+ wtWebGraphThermoHygroClockMonth-July(7),
+ wtWebGraphThermoHygroClockMonth-August(8),
+ wtWebGraphThermoHygroClockMonth-September(9),
+ wtWebGraphThermoHygroClockMonth-October(10),
+ wtWebGraphThermoHygroClockMonth-November(11),
+ wtWebGraphThermoHygroClockMonth-December(12)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Date: Month, taking into account the time zone settings."
+ ::= { wtWebGraphThermoHygroDeviceClock 4 }
+
+wtWebGraphThermoHygroClockYear OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Date: Year, taking into account the time zone settings."
+ ::= { wtWebGraphThermoHygroDeviceClock 5 }
+
+
+-- wtWebGraphThermoHygroNetwork Group
+------------------------
+
+wtWebGraphThermoHygroIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "IP address of the Webio"
+ ::= { wtWebGraphThermoHygroNetwork 1 }
+
+wtWebGraphThermoHygroSubnetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Subnet mask of the Webio"
+ ::= { wtWebGraphThermoHygroNetwork 2 }
+
+wtWebGraphThermoHygroGateway OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Gateway of the Webio"
+ ::= { wtWebGraphThermoHygroNetwork 3 }
+
+wtWebGraphThermoHygroDnsServer1 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "IP address of the 1st DNS server in ASCII"
+ ::= { wtWebGraphThermoHygroNetwork 4 }
+
+wtWebGraphThermoHygroDnsServer2 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "IP address of the 2nd DNS server in ASCII"
+ ::= { wtWebGraphThermoHygroNetwork 5 }
+
+wtWebGraphThermoHygroAddConfig OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Additional configuration (1=ON):
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1: DHCP disable
+ Bit 0: BOOTP disable
+ "
+ ::= { wtWebGraphThermoHygroNetwork 6 }
+
+-- wtWebGraphThermoHygroHTTP Group
+--------------------------------
+
+wtWebGraphThermoHygroStartup OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded start page:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1: Index.htm
+ Bit 2: Home.htm
+ Bit 3: User.htm
+ Only one page may be selected at a time."
+ ::= { wtWebGraphThermoHygroHTTP 1 }
+
+wtWebGraphThermoHygroGetHeaderEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "If these bits are set, every answer of a short form GET question will be lead
+ by the IP-address and name of the device and/or a HTTP header:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1-6: unused
+ Bit 1 : GET HTTP enable
+ Bit 0 : GET Header enable"
+ ::= { wtWebGraphThermoHygroHTTP 2 }
+
+wtWebGraphThermoHygroHttpPort OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Definition of the standard HTML port (Default: 80)."
+ ::= { wtWebGraphThermoHygroHTTP 3 }
+
+
+-- wtWebGraphThermoHygroMail Group
+--------------------------------
+
+wtWebGraphThermoHygroMailAdName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Device name for mail administration."
+ ::= { wtWebGraphThermoHygroMail 1 }
+
+wtWebGraphThermoHygroMailReply OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Reply address for the mail server."
+ ::= { wtWebGraphThermoHygroMail 2 }
+
+wtWebGraphThermoHygroMailServer OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name or IP address of the mail server."
+ ::= { wtWebGraphThermoHygroMail 3 }
+
+wtWebioAn1MailEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set this bit to enable the sending of mails:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1-7: unused
+ Bit 0 : Mail enable"
+ ::= { wtWebGraphThermoHygroMail 4 }
+
+wtWebGraphThermoHygroMailAuthentication OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Selection of the authentication modi:
+ The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
+ Bit 0 corresponds to the LSB.
+ OCTET 1: unused
+ OCTET 2: unused
+ OCTET 3: unused
+ OCTET 4: Bit 3-7: unused
+ Bit 2 : POP3 before SMTP
+ Bit 1 : ESMTP, authentication
+ Bit 0 : SMTP, no authentication"
+ ::= { wtWebGraphThermoHygroMail 5 }
+
+wtWebGraphThermoHygroMailAuthUser OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name of the user to be authenticated."
+ ::= { wtWebGraphThermoHygroMail 6 }
+
+wtWebGraphThermoHygroMailAuthPassword OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Authentication password."
+ ::= { wtWebGraphThermoHygroMail 7 }
+
+wtWebGraphThermoHygroMailPop3Server OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name or Ip-address of the POP3 Servers."
+ ::= { wtWebGraphThermoHygroMail 8 }
+
+-- wtWebGraphThermoHygroSNMP Group
+--------------------------------
+
+wtWebGraphThermoHygroSnmpCommunityStringRead OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Community string read only"
+ ::= { wtWebGraphThermoHygroSNMP 1 }
+
+wtWebGraphThermoHygroSnmpCommunityStringReadWrite OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Community string read / write"
+ ::= { wtWebGraphThermoHygroSNMP 2 }
+
+wtWebGraphThermoHygroSystemTrapManagerIP OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name or IP address of the TCP server which accepts the system trap."
+ ::= { wtWebGraphThermoHygroSNMP 3 }
+
+wtWebGraphThermoHygroSystemTrapEnable OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded trigger conditions:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0: ColdStart
+ Bit 1: WarmStart
+ Bit 2-7: unused"
+ ::= { wtWebGraphThermoHygroSNMP 4 }
+
+wtWebGraphThermoHygroSnmpEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set bit 0 to enable SNMP.
+ If disabled, the device did not respond to any SNMP requests.
+ Bit 1 decided wether the community string of read operations
+ is compared with the system password or not:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1-7: unused
+ Bit 0 : SNMP enable"
+ ::= { wtWebGraphThermoHygroSNMP 5 }
+
+wtWebGraphThermoHygroSnmpCommunityStringTrap OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Community string send within traps."
+ ::= { wtWebGraphThermoHygroSNMP 6 }
+
+wtWebGraphThermoHygroSnmpSystemTrapManagerPort OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Port number of the TCP server which accepts the system trap."
+ ::= { wtWebGraphThermoHygroSNMP 7 }
+
+-- wtWebGraphThermoHygroUDP Group
+--------------------------------
+
+wtWebGraphThermoHygroUdpPort OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Udp port to which the Udp queries ( short form GET requests) can be sent. This
+ port number must be unique within the device."
+ ::= { wtWebGraphThermoHygroUDP 1 }
+
+wtWebGraphThermoHygroUdpEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set this bit to enable UDP support:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1-7: unused
+ Bit 0 : UDP enable"
+ ::= { wtWebGraphThermoHygroUDP 2 }
+
+-- wtWebGraphThermoHygroSyslog Group
+--------------------------------
+
+wtWebGraphThermoHygroSyslogServerIP OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name or IP address of the Syslog server, which accepts the Syslog messgaes."
+ ::= { wtWebGraphThermoHygroSyslog 1 }
+
+wtWebGraphThermoHygroSyslogServerPort OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Portnumber of the Syslog servers, default 514."
+ ::= { wtWebGraphThermoHygroSyslog 2 }
+
+wtWebGraphThermoHygroSyslogSystemMessagesEnable OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded trigger conditions:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0: ColdStart
+ Bit 1: WarmStart
+ Bit 2: Diag Messages
+ Bit 3-7: unused"
+ ::= { wtWebGraphThermoHygroSyslog 3 }
+
+wtWebGraphThermoHygroSyslogEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set bit 0to enable Syslog:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1-7: unused
+ Bit 0 : Syslog enable"
+ ::= { wtWebGraphThermoHygroSyslog 4 }
+
+-- wtWebGraphThermoHygroFTP Group
+--------------------------------
+
+wtWebGraphThermoHygroFTPServerIP OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name or IP address of the FTP server, which accepts the FTP messages."
+ ::= { wtWebGraphThermoHygroFTP 1 }
+
+wtWebGraphThermoHygroFTPServerControlPort OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Portnumber of the control port of the FTP server, default 21."
+ ::= { wtWebGraphThermoHygroFTP 2 }
+
+wtWebGraphThermoHygroFTPUserName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "FTP Loggin: user name."
+ ::= { wtWebGraphThermoHygroFTP 3 }
+
+wtWebGraphThermoHygroFTPPassword OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "FTP Loggin: user password."
+ ::= { wtWebGraphThermoHygroFTP 4 }
+
+wtWebGraphThermoHygroFTPAccount OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "FTP Loggin: name of account."
+ ::= { wtWebGraphThermoHygroFTP 5 }
+
+wtWebGraphThermoHygroFTPOption OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Bit 0 switches the FTP Server in Passiv-Mode,
+ the Client controls the data connection on its own:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1-7: unused
+ Bit 0 : PASV enable"
+ ::= { wtWebGraphThermoHygroFTP 6 }
+
+wtWebGraphThermoHygroFTPEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set Bit 0 to enable FTP:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1-7: unused
+ Bit 0 : FTP enable"
+ ::= { wtWebGraphThermoHygroFTP 7 }
+
+-- wtWebGraphThermoHygroLanguage Group
+--------------------------------
+
+wtWebGraphThermoHygroLanguageSelect OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sprachauswahl:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 2-7: ungenutzt
+ Bit 1 : Englisch
+ Bit 0 : Deutsch"
+ ::= { wtWebGraphThermoHygroLanguage 1 }
+
+-- wtWebGraphThermoHygroMQTT Group
+--------------------------------
+
+wtWebGraphThermoHygroMQTTEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Bit 7 schaltet MQTT frei:
+ Octet 1: ungenutzt
+ Octet 2: ungenutzt
+ Octet 3: ungenutzt
+ Octet 4:
+ Bit 0-6: ungenutzt
+ Bit 7 : MQTT enable"
+ ::= { wtWebGraphThermoHygroMQTT 1 }
+
+wtWebGraphThermoHygroMQTTBrockerIP OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name or IP-address of the MQTT-Server."
+ ::= { wtWebGraphThermoHygroMQTT 2 }
+
+wtWebGraphThermoHygroMQTTUserName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "MQTT login user name."
+ ::= { wtWebGraphThermoHygroMQTT 3 }
+
+wtWebGraphThermoHygroMQTTPassword OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "MQTT login password."
+ ::= { wtWebGraphThermoHygroMQTT 4 }
+
+wtWebGraphThermoHygroMQTTLocalPort OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Local port number."
+ ::= { wtWebGraphThermoHygroMQTT 5 }
+
+wtWebGraphThermoHygroMQTTBrokerServerPort OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "MQTT Server port number."
+ ::= { wtWebGraphThermoHygroMQTT 6 }
+
+wtWebGraphThermoHygroMQTTInterval OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Ping intervall, if no data has to be send: time in seconds."
+ ::= { wtWebGraphThermoHygroMQTT 7 }
+
+wtWebGraphThermoHygroMQTTLastWillEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Bit 0 activate MQTT LastWill message:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1-7: unused
+ Bit 0 : MQTT Last will enable"
+ ::= { wtWebGraphThermoHygroMQTT 8 }
+
+wtWebGraphThermoHygroMQTTLastWillTopic OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "MQTT Last Will Topic."
+ ::= { wtWebGraphThermoHygroMQTT 9 }
+
+wtWebGraphThermoHygroMQTTLastWillMsg OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "MQTT Last Will message."
+ ::= { wtWebGraphThermoHygroMQTT 10 }
+
+wtWebGraphThermoHygroMQTTLastWillQoS OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded MQTT Publish QoS:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0: QoS 0
+ Bit 1: QoS 1
+ Bit 2: QoS 2
+ Bit 3-7:unused"
+ ::= { wtWebGraphThermoHygroMQTT 11 }
+
+wtWebGraphThermoHygroMQTTLastWillRetain OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded MQTT Publish Retain properties:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0 : retain enable
+ Bit 1-7 : unused"
+ ::= { wtWebGraphThermoHygroMQTT 12 }
+
+wtWebGraphThermoHygroMQTTLastWillConnectEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Bit 0 activate MQTT LastWill Connect message:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1-7: unused
+ Bit 0 : MQTT Last will connect message enable"
+ ::= { wtWebGraphThermoHygroMQTT 13 }
+
+wtWebGraphThermoHygroMQTTLastWillConnectMsg OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "MQTT Last Will Connect message will be send with the QoS and Retain settings
+ of the LastWill message."
+ ::= { wtWebGraphThermoHygroMQTT 14 }
+
+
+-- wtWebGraphThermoHygroREST Group
+--------------------------------
+
+wtWebGraphThermoHygroRESTEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Bit 0 activates REST :
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1-7: unused
+ Bit 0 : REST enable"
+ ::= { wtWebGraphThermoHygroREST 1 }
+
+wtWebGraphThermoHygroRESTDigestAuthEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Bit 0 activates Digest-Authentification:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 1-7: unused
+ Bit 0 : Digest Auth enable"
+ ::= { wtWebGraphThermoHygroREST 2 }
+
+-- wtWebGraphThermoHygroDatalogger Group
+--------------------------------
+
+wtWebGraphThermoHygroLoggerTimebase OBJECT-TYPE
+ SYNTAX INTEGER {
+ wtWebGraphThermoHygroDatalogger-1Min(1),
+ wtWebGraphThermoHygroDatalogger-5Min(2),
+ wtWebGraphThermoHygroDatalogger-15Min(3),
+ wtWebGraphThermoHygroDatalogger-60Min(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Time base of the data logger"
+ ::= { wtWebGraphThermoHygroDatalogger 1 }
+
+wtWebGraphThermoHygroLoggerSensorSel OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded trigger conditions:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0: Sensor 1
+ Bit 1: Sensor 2
+ Bit 2-7: unused"
+ ::= { wtWebGraphThermoHygroDatalogger 2 }
+
+-- wtWebGraphThermoHygroRSS Group
+--------------------------------
+
+wtWebGraphThermoHygroRSSChannelTitle OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name of the RSS Feed."
+ ::= { wtWebGraphThermoHygroRSS 1 }
+
+wtWebGraphThermoHygroRSSChannelLink OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Link of the RSS Feed."
+ ::= { wtWebGraphThermoHygroRSS 2 }
+
+wtWebGraphThermoHygroRSSChannelDescription OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Description of the RSS Feed."
+ ::= { wtWebGraphThermoHygroRSS 3 }
+
+wtWebGraphThermoHygroRSSChannelImage OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Link of a picture, which will be shown at the headline of the output window."
+ ::= { wtWebGraphThermoHygroRSS 4 }
+
+wtWebGraphThermoHygroRSSChannelImageTitle OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Alias Name of the picture."
+ ::= { wtWebGraphThermoHygroRSS 5 }
+
+wtWebGraphThermoHygroRSSChannelImageLink OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Link, which can be selected by clicking on the picture."
+ ::= { wtWebGraphThermoHygroRSS 6 }
+
+wtWebGraphThermoHygroRSSChannelItemTitle OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Title of the RSS Feed."
+ ::= { wtWebGraphThermoHygroRSS 7 }
+
+wtWebGraphThermoHygroRSSChannelItemLink OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Link of the RSS Feed."
+ ::= { wtWebGraphThermoHygroRSS 8 }
+
+wtWebGraphThermoHygroRSSChannelItemDescription OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Text of the RSS Feed."
+ ::= { wtWebGraphThermoHygroRSS 9 }
+
+wtWebGraphThermoHygroRSSChannelItemQuantity OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Number of lines."
+ ::= { wtWebGraphThermoHygroRSS 10 }
+
+-- wtWebGraphThermoHygroAlarm Group
+----------------------------
+
+wtWebGraphThermoHygroAlarmCount OBJECT-TYPE
+ SYNTAX INTEGER (1..8)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Number of independent alarms."
+ ::= { wtWebGraphThermoHygroAlarm 1 }
+
+-- Alarm Interface Table
+
+wtWebGraphThermoHygroAlarmIfTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WtWebGraphThermoHygroAlarmIfEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "List of alarm indices."
+ ::= { wtWebGraphThermoHygroAlarm 2 }
+
+wtWebGraphThermoHygroAlarmIfEntry OBJECT-TYPE
+ SYNTAX WtWebGraphThermoHygroAlarmIfEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Numbers of the alarms."
+ INDEX { wtWebGraphThermoHygroAlarmNo }
+ ::= { wtWebGraphThermoHygroAlarmIfTable 1 }
+
+WtWebGraphThermoHygroAlarmIfEntry ::= SEQUENCE {
+ wtWebGraphThermoHygroAlarmNo INTEGER
+}
+
+wtWebGraphThermoHygroAlarmNo OBJECT-TYPE
+ SYNTAX INTEGER (1..8)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm number."
+ ::= { wtWebGraphThermoHygroAlarmIfEntry 1 }
+
+-- Alarm Table
+
+wtWebGraphThermoHygroAlarmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WtWebGraphThermoHygroAlarmEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "List of settings depending on the alarm number."
+ ::= { wtWebGraphThermoHygroAlarm 3 }
+
+wtWebGraphThermoHygroAlarmEntry OBJECT-TYPE
+ SYNTAX WtWebGraphThermoHygroAlarmEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm parameters of the individual alarms."
+ INDEX { wtWebGraphThermoHygroAlarmNo }
+ ::= { wtWebGraphThermoHygroAlarmTable 1 }
+
+WtWebGraphThermoHygroAlarmEntry ::= SEQUENCE {
+ wtWebGraphThermoHygroAlarmTrigger OCTET STRING,
+ wtWebGraphThermoHygroAlarmMin OCTET STRING,
+ wtWebGraphThermoHygroAlarmMax OCTET STRING,
+ wtWebGraphThermoHygroAlarmHysteresis OCTET STRING,
+ wtWebGraphThermoHygroAlarmDelay OCTET STRING,
+ wtWebGraphThermoHygroAlarmInterval OCTET STRING,
+ wtWebGraphThermoHygroAlarmEnable OCTET STRING,
+ wtWebGraphThermoHygroAlarmEMailAddr OCTET STRING,
+ wtWebGraphThermoHygroAlarmMailSubject OCTET STRING,
+ wtWebGraphThermoHygroAlarmMailText OCTET STRING,
+ wtWebGraphThermoHygroAlarmManagerIP OCTET STRING,
+ wtWebGraphThermoHygroAlarmTrapText OCTET STRING,
+ wtWebGraphThermoHygroAlarmMailOptions OCTET STRING,
+ wtWebGraphThermoHygroAlarmTcpIpAddr OCTET STRING,
+ wtWebGraphThermoHygroAlarmTcpPort INTEGER,
+ wtWebGraphThermoHygroAlarmTcpText OCTET STRING,
+ wtWebGraphThermoHygroAlarmClearMailSubject OCTET STRING,
+ wtWebGraphThermoHygroAlarmClearMailText OCTET STRING,
+ wtWebGraphThermoHygroAlarmClearTrapText OCTET STRING,
+ wtWebGraphThermoHygroAlarmClearTcpText OCTET STRING,
+ wtWebGraphThermoHygroAlarmDeltaTemp OCTET STRING,
+ wtWebGraphThermoHygroAlarmRHMin OCTET STRING,
+ wtWebGraphThermoHygroAlarmRHMax OCTET STRING,
+ wtWebGraphThermoHygroAlarmRHHysteresis OCTET STRING,
+ wtWebGraphThermoHygroAlarmAHMin OCTET STRING,
+ wtWebGraphThermoHygroAlarmAHMax OCTET STRING,
+ wtWebGraphThermoHygroAlarmSyslogIpAddr OCTET STRING,
+ wtWebGraphThermoHygroAlarmSyslogPort INTEGER,
+ wtWebGraphThermoHygroAlarmSyslogText OCTET STRING,
+ wtWebGraphThermoHygroAlarmSyslogClearText OCTET STRING,
+ wtWebGraphThermoHygroAlarmFtpDataPort OCTET STRING,
+ wtWebGraphThermoHygroAlarmFtpFileName OCTET STRING,
+ wtWebGraphThermoHygroAlarmFtpText OCTET STRING,
+ wtWebGraphThermoHygroAlarmFtpClearText OCTET STRING,
+ wtWebGraphThermoHygroAlarmFtpOption OCTET STRING,
+ wtWebGraphThermoHygroAlarmTimerCron OCTET STRING,
+ wtWebGraphThermoHygroAlarmName OCTET STRING,
+ wtWebGraphThermoHygroAlarmActive OCTET STRING,
+ wtWebGraphThermoHygroAlarmHttpReqAuthEnable OCTET STRING,
+ wtWebGraphThermoHygroAlarmHttpReqAuthUser OCTET STRING,
+ wtWebGraphThermoHygroAlarmHttpReqAuthPassword OCTET STRING,
+ wtWebGraphThermoHygroAlarmHttpReqSetUrl OCTET STRING,
+ wtWebGraphThermoHygroAlarmHttpReqClearUrl OCTET STRING,
+ wtWebGraphThermoHygroAlarmHttpReqServerPort INTEGER,
+ wtWebGraphThermoHygroAlarmMqttTopicPath OCTET STRING,
+ wtWebGraphThermoHygroAlarmMqttTopicSetTopic OCTET STRING,
+ wtWebGraphThermoHygroAlarmMqttTopicClear OCTET STRING,
+ wtWebGraphThermoHygroAlarmSensorLostSelection OCTET STRING,
+ wtWebGraphThermoHygroAlarmLimitWindow OCTET STRING,
+ wtWebGraphThermoHygroAlarmSnmpManagerPort INTEGER,
+ wtWebGraphThermoHygroAlarmMqttQoS OCTET STRING,
+ wtWebGraphThermoHygroAlarmMqttRetain OCTET STRING
+}
+
+wtWebGraphThermoHygroAlarmTrigger OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded trigger conditions:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3:
+ Bit 0: Timer
+ Bit 1: ColdStart
+ Bit 2: WarmStart
+
+ Octet 4:
+ Bit 0: Sensor 1
+ Bit 1: Sensor 2
+ Bit 2-7: unused"
+ ::= { wtWebGraphThermoHygroAlarmEntry 1 }
+
+wtWebGraphThermoHygroAlarmMin OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Minimum temperature in degrees with maximum 2 decimal places."
+ ::= { wtWebGraphThermoHygroAlarmEntry 2 }
+
+wtWebGraphThermoHygroAlarmMax OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Maximum temperature in degrees with maximum 2 decimal places."
+ ::= { wtWebGraphThermoHygroAlarmEntry 3 }
+
+wtWebGraphThermoHygroAlarmHysteresis OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
+ , in degrees with maximum 2 decimal places."
+ ::= { wtWebGraphThermoHygroAlarmEntry 4 }
+
+wtWebGraphThermoHygroAlarmDelay OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm will be delayed by setting this time while stable alarm
+ condition occur (time in minutes)."
+ ::= { wtWebGraphThermoHygroAlarmEntry 5 }
+
+
+wtWebGraphThermoHygroAlarmInterval OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Send interval for alarm messages."
+ ::= { wtWebGraphThermoHygroAlarmEntry 6 }
+
+wtWebGraphThermoHygroAlarmEnable OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded alarm enable:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0: Mail Enable
+ Bit 1: SNMP Trap enable
+ Bit 2: TCP Client enable"
+ ::= { wtWebGraphThermoHygroAlarmEntry 7 }
+
+wtWebGraphThermoHygroAlarmEMailAddr OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "E-Mail address for sending the alarm mail to."
+ ::= { wtWebGraphThermoHygroAlarmEntry 8 }
+
+wtWebGraphThermoHygroAlarmMailSubject OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Subject line for alarm mail."
+ ::= { wtWebGraphThermoHygroAlarmEntry 9 }
+
+wtWebGraphThermoHygroAlarmMailText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm mail text: <Tn> provides the current temperature; n = 1..8.
+ <Z> provides the current time."
+ ::= { wtWebGraphThermoHygroAlarmEntry 10 }
+
+wtWebGraphThermoHygroAlarmManagerIP OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name or IP address of the SNMP Manager which accepts the trap."
+ ::= { wtWebGraphThermoHygroAlarmEntry 11 }
+
+wtWebGraphThermoHygroAlarmTrapText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This text is sent in the trap body."
+ ::= { wtWebGraphThermoHygroAlarmEntry 12 }
+
+wtWebGraphThermoHygroAlarmMailOptions OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded options:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0 : Attach Thermo.csv Enable
+ Bit 1 : CSV-Data_since_last_report
+ Bit 2-7: unused"
+ ::= { wtWebGraphThermoHygroAlarmEntry 13 }
+
+wtWebGraphThermoHygroAlarmTcpIpAddr OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name or IP address of the TCP server which accepts the trap."
+ ::= { wtWebGraphThermoHygroAlarmEntry 14 }
+
+wtWebGraphThermoHygroAlarmTcpPort OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Port number of the TCP server which accepts the trap."
+ ::= { wtWebGraphThermoHygroAlarmEntry 15 }
+
+wtWebGraphThermoHygroAlarmTcpText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This text is sent in the TCP trap body."
+ ::= { wtWebGraphThermoHygroAlarmEntry 16 }
+
+wtWebGraphThermoHygroAlarmClearMailSubject OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Subject line for alarm clear mail."
+ ::= { wtWebGraphThermoHygroAlarmEntry 17 }
+
+wtWebGraphThermoHygroAlarmClearMailText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
+ <Z> provides the current time."
+ ::= { wtWebGraphThermoHygroAlarmEntry 18 }
+
+wtWebGraphThermoHygroAlarmClearTrapText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This text is sent in the trap body."
+ ::= { wtWebGraphThermoHygroAlarmEntry 19 }
+
+wtWebGraphThermoHygroAlarmClearTcpText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This text is sent in the TCP trap body."
+ ::= { wtWebGraphThermoHygroAlarmEntry 20 }
+
+wtWebGraphThermoHygroAlarmDeltaTemp OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Maximum rate of change degrees/min with maximum 2 decimal places.
+ Compared with the average of a period of 5 minutes."
+ ::= { wtWebGraphThermoHygroAlarmEntry 21 }
+
+wtWebGraphThermoHygroAlarmRHMin OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Minimum rel. Humidity in percent with maximum 2 decimal places."
+ ::= { wtWebGraphThermoHygroAlarmEntry 22 }
+
+wtWebGraphThermoHygroAlarmRHMax OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Maximum rel.Humidity in percent with maximum 2 decimal places."
+ ::= { wtWebGraphThermoHygroAlarmEntry 23 }
+
+wtWebGraphThermoHygroAlarmRHHysteresis OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Hysterese rel. Humidity in percent with maximum 2 decimal places."
+ ::= { wtWebGraphThermoHygroAlarmEntry 24 }
+
+wtWebGraphThermoHygroAlarmAHMin OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Minimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places."
+ ::= { wtWebGraphThermoHygroAlarmEntry 25 }
+
+wtWebGraphThermoHygroAlarmAHMax OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Maximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places."
+ ::= { wtWebGraphThermoHygroAlarmEntry 26 }
+
+wtWebGraphThermoHygroAlarmSyslogIpAddr OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "IP address of the syslog server to which the Webio device should send syslog messages."
+ ::= { wtWebGraphThermoHygroAlarmEntry 27 }
+
+wtWebGraphThermoHygroAlarmSyslogPort OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Port number of the syslog server to which the Webio device should send syslog messages."
+ ::= { wtWebGraphThermoHygroAlarmEntry 28 }
+
+wtWebGraphThermoHygroAlarmSyslogText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
+ This text appears in the following syslog message body."
+ ::= { wtWebGraphThermoHygroAlarmEntry 29 }
+
+wtWebGraphThermoHygroAlarmSyslogClearText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
+ This text appears in the following syslog message body."
+ ::= { wtWebGraphThermoHygroAlarmEntry 30 }
+
+wtWebGraphThermoHygroAlarmFtpDataPort OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Local data port: 1..65535 or AUTO: the next free port will be assigned."
+ ::= { wtWebGraphThermoHygroAlarmEntry 31 }
+
+wtWebGraphThermoHygroAlarmFtpFileName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name of the file including path informations."
+ ::= { wtWebGraphThermoHygroAlarmEntry 32 }
+
+wtWebGraphThermoHygroAlarmFtpText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Message text to store on the FTP server."
+ ::= { wtWebGraphThermoHygroAlarmEntry 33 }
+
+wtWebGraphThermoHygroAlarmFtpClearText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm clear message to store on the FTP server."
+ ::= { wtWebGraphThermoHygroAlarmEntry 34 }
+
+wtWebGraphThermoHygroAlarmFtpOption OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded options, select only one option at the same time:
+ STORE = replace file
+ APPEND = append message at the end of the file
+
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0 : STORE
+ Bit 1 : APPEND
+ Bit 2-7: unused"
+ ::= { wtWebGraphThermoHygroAlarmEntry 35 }
+
+wtWebGraphThermoHygroAlarmTimerCron OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This entry contains 5 space or tab seperated text fields for time trigger definition.
+ Each field must match with the actual time to trigger a message, weekday and day of month
+ are interpreted separatley.
+ 1: Minutes Range 0-59
+ 2. Hours Range 0-23, 0 is midnight
+ 3: Day of month Range 1-31
+ 4: Month Range 1-12
+ 5: Weekday Range 0-6, 0 is sunday
+
+ Syntax for every field:
+ - an asterix (*) enables every possible setting of a field
+ - single numbers seperated by commas
+ - a partition within the allowed range (1-5)
+ - step size within an partition of the allowed range (0-59/2: every second minute)."
+ ::= { wtWebGraphThermoHygroAlarmEntry 36 }
+
+-- __JB__
+wtWebGraphThermoHygroAlarmName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Alert name"
+ ::= { wtWebGraphThermoHygroAlarmEntry 39 }
+
+-- __JB__
+wtWebGraphThermoHygroAlarmActive OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Alert active
+ 1 = ON
+ 0 = OFF"
+ ::= { wtWebGraphThermoHygroAlarmEntry 40 }
+
+wtWebGraphThermoHygroAlarmHttpReqAuthEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded options, select only one option at the same time:
+ OCTET 1: unused
+ OCTET 2: unused
+ OCTET 3: unused
+ OCTET 4, Bit 1-7: unused
+ Bit 0 : HHTP Request Authentication enable"
+ ::= { wtWebGraphThermoHygroAlarmEntry 61 }
+
+wtWebGraphThermoHygroAlarmHttpReqAuthUser OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "HTTP Request: User"
+ ::= { wtWebGraphThermoHygroAlarmEntry 62 }
+
+wtWebGraphThermoHygroAlarmHttpReqAuthPassword OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "HTTP Request: Password"
+ ::= { wtWebGraphThermoHygroAlarmEntry 63 }
+
+wtWebGraphThermoHygroAlarmHttpReqSetUrl OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "HTTP Request: Set URL"
+ ::= { wtWebGraphThermoHygroAlarmEntry 64 }
+
+wtWebGraphThermoHygroAlarmHttpReqClearUrl OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "HTTP Request: Clear URL"
+ ::= { wtWebGraphThermoHygroAlarmEntry 65 }
+
+wtWebGraphThermoHygroAlarmHttpReqServerPort OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "HTTP Request: Server Port"
+ ::= { wtWebGraphThermoHygroAlarmEntry 66 }
+
+wtWebGraphThermoHygroAlarmMqttTopicPath OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "MQTT Publish: Topic path"
+ ::= { wtWebGraphThermoHygroAlarmEntry 67 }
+
+wtWebGraphThermoHygroAlarmMqttTopicSetTopic OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "MQTT Publish: Topic SET message"
+ ::= { wtWebGraphThermoHygroAlarmEntry 68 }
+
+wtWebGraphThermoHygroAlarmMqttTopicClear OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "MQTT Publish: Topic CLEAR message"
+ ::= { wtWebGraphThermoHygroAlarmEntry 69 }
+
+wtWebGraphThermoHygroAlarmSensorLostSelection OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded options:
+ OCTET 1: unused
+ OCTET 2: unused
+ OCTET 3: unused
+ OCTET 4, Bit 2-7: unused
+ Bit 1 : Sensor 1
+ Bit 0 : Sensor 0"
+ ::= { wtWebGraphThermoHygroAlarmEntry 70 }
+
+wtWebGraphThermoHygroAlarmLimitWindow OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "If window type is INSIDE the alarm is genereted when the temperature
+ is greater minumum value and lower than maximum value. If window type is OUTSIDE
+ the alarm is generated when the measured value is lower than the minimum value
+ or greater than the maximum value.
+ Binary coded options, select only one option at the same time:
+ OCTET 1: unused
+ OCTET 2: unused
+ OCTET 3: unused
+ OCTET 4, Bit 2-7: unused
+ Bit 1 : inside window
+ Bit 0 : outside window"
+ ::= { wtWebGraphThermoHygroAlarmEntry 71 }
+
+wtWebGraphThermoHygroAlarmSnmpManagerPort OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Port number of the SNMP Manager to which the Webio device should send SNMP traps."
+ ::= { wtWebGraphThermoHygroAlarmEntry 76 }
+
+wtWebGraphThermoHygroAlarmMqttQoS OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded value:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0: QoS 0
+ Bit 1: QoS 1
+ Bit 2: QoS 2
+ Bit 3-7:unused"
+ ::= { wtWebGraphThermoHygroAlarmEntry 77 }
+
+wtWebGraphThermoHygroAlarmMqttRetain OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded value:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0 : retain enable
+ Bit 1-7 : unused"
+ ::= { wtWebGraphThermoHygroAlarmEntry 78 }
+
+-- wtWebGraphThermoHygroGraphicsBase Group
+----------------------------
+
+wtWebGraphThermoHygroGraphicsBaseEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Defines the viewing options of the graphic:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0 : Auto scroll enable
+ Bit 1 : Show table
+ Bit 2 : Show graph
+ Bit 3 : Show control buttons
+ Bit 4 : Show config menu
+ Bit 5-7: unused"
+ ::= { wtWebGraphThermoHygroGraphicsBase 1 }
+
+wtWebGraphThermoHygroGraphicsBaseWidth OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Defines the width of the graphic in pixels."
+ ::= { wtWebGraphThermoHygroGraphicsBase 2 }
+
+wtWebGraphThermoHygroGraphicsBaseHeight OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Defines the height of the graphic in pixels."
+ ::= { wtWebGraphThermoHygroGraphicsBase 3 }
+
+wtWebGraphThermoHygroGraphicsBaseFrameColor OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(3))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Frame color definition in RGB."
+ ::= { wtWebGraphThermoHygroGraphicsBase 4 }
+
+wtWebGraphThermoHygroGraphicsBaseBackgroundColor OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(3))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Background color definition in RGB."
+ ::= { wtWebGraphThermoHygroGraphicsBase 5 }
+
+wtWebGraphThermoHygroGraphicsBasePollingrate OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Defines the pollingrate in seconds,
+ which defines the refreshing intervall of the graphic."
+ ::= { wtWebGraphThermoHygroGraphicsBase 6 }
+
+-- wtWebGraphThermoHygroGraphicsSelect Group
+----------------------------
+
+wtWebGraphThermoHygroGraphicsSelectDisplaySensorSel OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded sensor selection:
+ only selected sensors will be shown in the graphical presentation:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0: Sensor 1
+ Bit 1: Sensor 2
+ Bit 2-7: unused"
+ ::= { wtWebGraphThermoHygroGraphicsSelect 1 }
+
+wtWebGraphThermoHygroGraphicsSelectDisplayShowExtrem OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(4))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Binary coded sensor selection:
+ only selected sensors will be shown with minima and maxima:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0: Sensor 1
+ Bit 1: Sensor 2
+ Bit 2-7: unused"
+ ::= { wtWebGraphThermoHygroGraphicsSelect 2 }
+
+-- Graph Sensor Color Table
+
+wtWebGraphThermoHygroSensorColorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WtWebGraphThermoHygroSensorColorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "List of sensor colors for the praphical presentation."
+ ::= { wtWebGraphThermoHygroGraphicsSelect 3 }
+
+wtWebGraphThermoHygroSensorColorEntry OBJECT-TYPE
+ SYNTAX WtWebGraphThermoHygroSensorColorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Numbers of the sensors."
+ INDEX { wtWebGraphThermoHygroSensorNo }
+ ::= { wtWebGraphThermoHygroSensorColorTable 1 }
+
+WtWebGraphThermoHygroSensorColorEntry ::= SEQUENCE {
+ wtWebGraphThermoHygroGraphicsSensorColor OCTET STRING,
+ wtWebGraphThermoHygroGraphicsSelectScale OCTET STRING
+}
+
+wtWebGraphThermoHygroGraphicsSensorColor OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(3))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Color of the sensors at the praphical presention."
+ ::= { wtWebGraphThermoHygroSensorColorEntry 1 }
+
+wtWebGraphThermoHygroGraphicsSelectScale OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Assignes one of 4 scales to a sensor:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0 : Use Scale 1
+ Bit 1 : Use Scale 2
+ Bit 2-7: unused"
+ ::= { wtWebGraphThermoHygroSensorColorEntry 2 }
+
+-- wtWebGraphThermoHygroGraphicsScale Group
+----------------------------
+
+wtWebGraphThermoHygroGraphicsScaleAutoScaleEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Select the Auto Scale Mode:
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0 : Scale 1 Auto scale enable
+ Bit 1 : Scale 2 Auto scale enable
+ Bit 2-7: unused"
+ ::= { wtWebGraphThermoHygroGraphicsScale 1 }
+
+
+wtWebGraphThermoHygroGraphicsScaleAutoFitEnable OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Select the Auto Fit Mode::
+ Octet 1: unused
+ Octet 2: unused
+ Octet 3: unused
+ Octet 4:
+ Bit 0 : Scale 1 Auto fit enable
+ Bit 1 : Scale 2 Auto fit enable
+ Bit 2-7: unused"
+ ::= { wtWebGraphThermoHygroGraphicsScale 2 }
+
+wtWebGraphThermoHygroGraphicsScale1Min OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Scale 1: Minimum."
+ ::= { wtWebGraphThermoHygroGraphicsScale 3 }
+
+wtWebGraphThermoHygroGraphicsScale2Min OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Scale 2: Minimum."
+ ::= { wtWebGraphThermoHygroGraphicsScale 4 }
+
+wtWebGraphThermoHygroGraphicsScale3Min OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Scale 3: Minimum."
+ ::= { wtWebGraphThermoHygroGraphicsScale 5 }
+
+wtWebGraphThermoHygroGraphicsScale4Min OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Scale 4: Minimum."
+ ::= { wtWebGraphThermoHygroGraphicsScale 6 }
+
+wtWebGraphThermoHygroGraphicsScale1Max OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Scale 1: Maximum."
+ ::= { wtWebGraphThermoHygroGraphicsScale 7 }
+
+wtWebGraphThermoHygroGraphicsScale2Max OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Scale 2: Maximum."
+ ::= { wtWebGraphThermoHygroGraphicsScale 8 }
+
+wtWebGraphThermoHygroGraphicsScale3Max OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Scale 3: Maximum."
+ ::= { wtWebGraphThermoHygroGraphicsScale 9 }
+
+wtWebGraphThermoHygroGraphicsScale4Max OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Scale 4: Maximum."
+ ::= { wtWebGraphThermoHygroGraphicsScale 10 }
+
+wtWebGraphThermoHygroGraphicsScale1Unit OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Scale 1: Unit."
+ ::= { wtWebGraphThermoHygroGraphicsScale 11 }
+
+wtWebGraphThermoHygroGraphicsScale2Unit OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Scale 2: Unit."
+ ::= { wtWebGraphThermoHygroGraphicsScale 12 }
+
+wtWebGraphThermoHygroGraphicsScale3Unit OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Scale 3: Unit."
+ ::= { wtWebGraphThermoHygroGraphicsScale 13 }
+
+wtWebGraphThermoHygroGraphicsScale4Unit OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Scale 4: Unit."
+ ::= { wtWebGraphThermoHygroGraphicsScale 14 }
+
+
+-- wtWebGraphThermoHygroPorts Group
+----------------------------
+
+-- Table
+
+wtWebGraphThermoHygroPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF WtWebGraphThermoHygroPortEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "List of settings depending on the sensor number."
+ ::= { wtWebGraphThermoHygroPorts 1 }
+
+wtWebGraphThermoHygroPortEntry OBJECT-TYPE
+ SYNTAX WtWebGraphThermoHygroPortEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Sensor parameters for the individual sensors."
+ INDEX { wtWebGraphThermoHygroSensorNo }
+ ::= { wtWebGraphThermoHygroPortTable 1 }
+
+WtWebGraphThermoHygroPortEntry ::= SEQUENCE {
+ wtWebGraphThermoHygroPortName OCTET STRING,
+ wtWebGraphThermoHygroPortText OCTET STRING,
+ wtWebGraphThermoHygroPortOffset1 OCTET STRING,
+ wtWebGraphThermoHygroPortTemperature1 OCTET STRING,
+ wtWebGraphThermoHygroPortOffset2 OCTET STRING,
+ wtWebGraphThermoHygroPortTemperature2 OCTET STRING,
+ wtWebGraphThermoHygroPortComment OCTET STRING
+}
+
+wtWebGraphThermoHygroPortName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Name of the sensor."
+ ::= { wtWebGraphThermoHygroPortEntry 1 }
+
+wtWebGraphThermoHygroPortText OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Description of the sensor."
+ ::= { wtWebGraphThermoHygroPortEntry 2 }
+
+wtWebGraphThermoHygroPortOffset1 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1."
+ ::= { wtWebGraphThermoHygroPortEntry 3 }
+
+wtWebGraphThermoHygroPortTemperature1 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
+ ::= { wtWebGraphThermoHygroPortEntry 4 }
+
+wtWebGraphThermoHygroPortOffset2 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2."
+ ::= { wtWebGraphThermoHygroPortEntry 5 }
+
+wtWebGraphThermoHygroPortTemperature2 OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
+ ::= { wtWebGraphThermoHygroPortEntry 6 }
+
+wtWebGraphThermoHygroPortComment OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Offset calibration: informations of date, name of operator, reference devices."
+ ::= { wtWebGraphThermoHygroPortEntry 7 }
+
+wtWebGraphThermoHygroPortAltidude OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Altidude oh the Sensor over mean sea level (MSL)."
+ ::= { wtWebGraphThermoHygroPorts 2 }
+
+-- wtWebGraphThermoHygroManufact Group
+----------------------------
+
+wtWebGraphThermoHygroMfName OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Manufacturer company name"
+ ::= { wtWebGraphThermoHygroManufact 1 }
+
+wtWebGraphThermoHygroMfAddr OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Manufacturer address."
+ ::= { wtWebGraphThermoHygroManufact 2 }
+
+wtWebGraphThermoHygroMfHotline OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Manufacturer hotline."
+ ::= { wtWebGraphThermoHygroManufact 3 }
+
+wtWebGraphThermoHygroMfInternet OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Manufacturer Internet address."
+ ::= { wtWebGraphThermoHygroManufact 4 }
+
+wtWebGraphThermoHygroMfDeviceTyp OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Manufacturer device name (model number)."
+ ::= { wtWebGraphThermoHygroManufact 5 }
+
+wtWebGraphThermoHygroMfOrderNo OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Manufacturer part number."
+ ::= { wtWebGraphThermoHygroManufact 6 }
+
+-- wtWebGraphThermoHygroDiag Group
+----------------------------
+
+wtWebGraphThermoHygroDiagErrorCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Number of entries in the error memory."
+ ::= { wtWebGraphThermoHygroDiag 1 }
+
+wtWebGraphThermoHygroDiagBinaryError OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Error causes coded bit-by-bit."
+ ::= { wtWebGraphThermoHygroDiag 2 }
+
+wtWebGraphThermoHygroDiagErrorIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this variable is used as an index to read
+ an error massege from wtWebGraphThermoHygroDiagErrorMessage.
+ Errors are numbered from 1 to wtWebGraphThermoHygroDiagErrorCount.
+ Writing a valid value into this variable, making the appropriate
+ message readable from wtWebGraphThermoHygroDiagErrorMessage."
+ ::= { wtWebGraphThermoHygroDiag 3 }
+
+wtWebGraphThermoHygroDiagErrorMessage OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Using wtWebGraphThermoHygroDiagErrorIndex as an index, the appropriate message is available."
+ ::= { wtWebGraphThermoHygroDiag 4 }
+
+wtWebGraphThermoHygroDiagErrorClear OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS write-only
+ STATUS mandatory
+ DESCRIPTION
+ "Writing 1 into this variable clears all diagnosis messages."
+ ::= { wtWebGraphThermoHygroDiag 5 }
+
+-- TRAP DEFINITIONS
+
+-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
+
+wtWebGraphThermoHygroAlert1 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 1 was triggered,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 1"
+ --#SUMMARY "Alarm 1: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 31
+
+wtWebGraphThermoHygroAlert2 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 2 was triggered,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 2"
+ --#SUMMARY "Alarm 2: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 32
+
+wtWebGraphThermoHygroAlert3 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 3 was triggered,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 3"
+ --#SUMMARY "Alarm 3: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 33
+
+wtWebGraphThermoHygroAlert4 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 4 was triggered,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 4"
+ --#SUMMARY "Alarm 4: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 34
+
+wtWebGraphThermoHygroAlert5 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 5 was triggered,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 5"
+ --#SUMMARY "Alarm 5: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 35
+
+wtWebGraphThermoHygroAlert6 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 6 was triggered,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 6"
+ --#SUMMARY "Alarm 6: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 36
+
+wtWebGraphThermoHygroAlert7 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 7 was triggered,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 7"
+ --#SUMMARY "Alarm 7: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 37
+
+wtWebGraphThermoHygroAlert8 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 8 was triggered,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Alarm 8"
+ --#SUMMARY "Alarm 8: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 38
+
+
+wtWebGraphThermoHygroAlert9 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 1 was cleared,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 1"
+ --#SUMMARY "Release Alarm 1: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 91
+
+wtWebGraphThermoHygroAlert10 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 2 was cleared,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 2"
+ --#SUMMARY "Release Alarm 2: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 92
+
+wtWebGraphThermoHygroAlert11 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 3 was cleared,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 3"
+ --#SUMMARY "Release Alarm 3: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 93
+
+wtWebGraphThermoHygroAlert12 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 4 was cleared,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 4"
+ --#SUMMARY "Release Alarm 4: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 94
+
+wtWebGraphThermoHygroAlert13 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 5 was cleared,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 5"
+ --#SUMMARY "Release Alarm 5: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 95
+
+wtWebGraphThermoHygroAlert14 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 6 was cleared,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 6"
+ --#SUMMARY "Release Alarm 6: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 96
+
+wtWebGraphThermoHygroAlert15 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 7 was cleared,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 7"
+ --#SUMMARY "Release Alarm 7: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 97
+
+wtWebGraphThermoHygroAlert16 TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
+ DESCRIPTION
+ "This SNMP trap is generated when Alarm 8 was cleared,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Release Alarm 8"
+ --#SUMMARY "Release Alarm 8: %s"
+ --#ARGUMENTS {0}
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 99
+ --#STATE OPERATIONAL
+ ::= 98
+
+wtWebGraphThermoHygroAlertDiag TRAP-TYPE
+ ENTERPRISE wtWebGraphThermoHygro
+ VARIABLES {
+ wtWebGraphThermoHygroDiagErrorIndex,
+ wtWebGraphThermoHygroDiagErrorMessage
+ }
+ DESCRIPTION
+ "This SNMP trap is generated when a diagnosis/error message was triggered,
+ SNMP trap enable is set and
+ SNMP is enabled."
+ -- NMS trap annotation
+ --#TYPE "Thermo-Hygrometer Diagnose Error"
+ --#SUMMARY "Diagnose error index: %d, Message: %s."
+ --#ARGUMENTS {0,1}
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 99
+ --#STATE DEGRADED
+ ::= 110
+
+END