summaryrefslogtreecommitdiff
path: root/MIBS/zyxel/ZYXEL-IESCOMMON-MIB
diff options
context:
space:
mode:
Diffstat (limited to 'MIBS/zyxel/ZYXEL-IESCOMMON-MIB')
-rw-r--r--MIBS/zyxel/ZYXEL-IESCOMMON-MIB2569
1 files changed, 2569 insertions, 0 deletions
diff --git a/MIBS/zyxel/ZYXEL-IESCOMMON-MIB b/MIBS/zyxel/ZYXEL-IESCOMMON-MIB
new file mode 100644
index 0000000..9305a8c
--- /dev/null
+++ b/MIBS/zyxel/ZYXEL-IESCOMMON-MIB
@@ -0,0 +1,2569 @@
+-- ZyXEL Communications Corporation
+-- Private Enterprise MIB definition
+
+-- $Log: zyxel-IESCommon.mib $
+-- Revision 1.2 2009/04/29 03:48:59 Ives
+-- Revision 1.1 2008/07/11 09:36:03 maverick
+-- Initial revision
+-- Revision 1.1 2008/07/07 05:54:40 JeFF
+-- Initial revision
+-- Revision 1.1 2006/08/28 05:32:53 kenny
+-- Initial revision
+-- Revision 1.7 2006/06/08 09:18:12 niceguy
+-- Revision 1.6 2006/05/29 06:52:00 niceguy
+-- Revision 1.5 2006/03/29 06:17:22 niceguy
+-- Revision 1.4 2006/03/24 08:04:14 niceguy
+-- Revision 1.3 2006/03/10 06:11:09 niceguy
+-- Revision 1.2 2006/03/07 06:36:57 niceguy
+-- Revision 1.1 2005/11/23 12:48:14 niceguy
+-- Initial revision
+-- Revision 1.4 2005/10/28 06:54:03 niceguy
+-- Revision 1.3 2005/09/21 08:59:14 niceguy
+-- Revision 1.2 2005/08/24 09:47:20 niceguy
+-- Revision 1.1 2005/08/18 13:30:39 Jeff
+-- Initial revision
+-- Revision 1.24 2005/06/17 05:42:50 jackho
+-- Add 'slc1224-22' for iesSlotModuleType, 'reject IP' for iesPacketFilter, iesRSTPEnable, iesSwitchMode and traps for adsl.
+-- Revision 1.23 2005/06/08 08:04:30 jennyhsu
+-- Changes for IES-2k/3k R3.02
+-- Revision 1.22 2004/06/08 10:12:12 jenny
+-- enhancement for R3.0: mac filter, packet filter, mac count limiting, 802.1x setting, radius server, new traps,
+-- new bit definition in system current status and module status
+-- Revision 1.21 2004/04/19 12:04:35 jennyhsu
+-- Change the value definition in iesSystemTimeZone to be synced with FW
+-- Revision 1.20 2004/02/26 03:59:03 jennyhsu
+-- Add objcet iesMscPortVLANTrunking and mscSwitchOverOK
+-- Revision 1.19 2004/02/05 10:17:00 Admin
+-- add "moduleDown" in iesSlotModuleAlarmStatus
+-- Revision 1.18 2003/11/25 04:00:47 jennyhsu
+-- add ADSL ETSI mode
+-- Revision 1.17 2003/11/07 09:17:02 jennyhsu
+-- Revision 1.16 2003/11/07 09:02:23 jennyhsu
+-- Add iesSNMPTrapDestTable
+-- Change FrameID to FrameNumber
+-- Revision 1.15 2003/09/19 05:00:51 jennyhsu
+-- Add thermalSensorFailure trap.
+-- Change the syntax of iesSysDhcpRelayOption82Info to be DisplayString
+-- Change iesSlotModuleAlarmStatus's definition
+-- Add iesMscPortMode
+-- Revision 1.14 2003/09/10 12:26:51 jennyhsu
+-- add DHCP setup
+-- Revision 1.13 2003/06/06 09:16:38 jennyhsu
+-- Revise the descriptions of iesMaintenanceDSLConfTarget
+-- Revision 1.12 2003/06/06 01:39:49 jennyhsu
+-- Add objects for DSL configuration in batch mode
+-- Revision 1.11 2003/05/07 06:47:25 jennyhsu
+-- Remove module type msc1300, vlc1316. Add msc1000A
+-- Revision 1.10 2003/03/28 01:38:01 jennyhsu
+-- Modify syntax of iesSlotModuleType and iesMscPortType
+-- Revision 1.9 2003/03/13 08:57:05 jennyhsu
+-- Revision 1.8 2003/03/13 07:56:29 jennyhsu
+-- Revision 1.7 2003/02/17 09:10:06 jennyhsu
+-- modify iesSlotModuleType, add alc1024-63 definition
+-- Revision 1.6 2003/01/06 09:01:03 jennyhsu
+-- Modify the Access of iesMscPortSpeed, iesMscPortDuplex, iesPortFlowControl,
+-- iesMscPortDefaultVLANTagging
+-- Revision 1.5 2002/12/03 07:47:15 jennyhsu
+-- Add modulePlugIn and modulePullOut trap
+-- Revision 1.4 2002/11/20 11:35:09 jennyhsu
+-- Modify the variable bindings in the moduleUp trap
+-- Revision 1.3 2002/11/20 08:40:11 jennyhsu
+-- Modify the enterprise clause of trap definition from iesSeriesCommon to
+-- iesSeries
+-- Revision 1.2 2002/11/12 07:47:20 jennyhsu
+-- Revision 1.1 2002/11/12 07:40:50 jennyhsu
+-- Initial revision
+
+
+ZYXEL-IESCOMMON-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+
+ OBJECT-TYPE, NOTIFICATION-TYPE, IpAddress
+ FROM SNMPv2-SMI
+-- FROM RFC-1212
+ DisplayString, ifIndex, PhysAddress
+ FROM RFC1213-MIB
+ RowStatus
+ FROM SNMPv2-TC
+ PortList
+ FROM Q-BRIDGE-MIB
+ TRAP-TYPE
+ FROM RFC-1215
+ MacAddress, Timeout, BridgeId
+ FROM BRIDGE-MIB
+ iesSeries, iesSeriesCommon
+ FROM ZYXEL-MIB;
+
+ iesChassis OBJECT IDENTIFIER ::= { iesSeriesCommon 1 }
+ iesHWMonitor OBJECT IDENTIFIER ::= { iesSeriesCommon 2 }
+ iesSysMgnt OBJECT IDENTIFIER ::= { iesSeriesCommon 3 }
+
+ iesSysState OBJECT IDENTIFIER ::= { iesSysMgnt 1 }
+ iesSysMaintenance OBJECT IDENTIFIER ::= { iesSysMgnt 2 }
+ iesSysTimeSetup OBJECT IDENTIFIER ::= { iesSysMgnt 3 }
+ iesSysAccessControl OBJECT IDENTIFIER ::= { iesSysMgnt 4 }
+ iesSysStaticRoute OBJECT IDENTIFIER ::= { iesSysMgnt 5 }
+ iesSyslogSetup OBJECT IDENTIFIER ::= { iesSysMgnt 6 }
+ iesSysDhcpSetup OBJECT IDENTIFIER ::= { iesSysMgnt 7 }
+ iesSysSNMPSetup OBJECT IDENTIFIER ::= { iesSysMgnt 8 }
+ iesSysDot1xSetup OBJECT IDENTIFIER ::= { iesSysMgnt 9 }
+ iesSysMacFilter OBJECT IDENTIFIER ::= { iesSysMgnt 10 }
+ iesSysPacketFilter OBJECT IDENTIFIER ::= { iesSysMgnt 11 }
+ iesSysMacCountFilter OBJECT IDENTIFIER ::= { iesSysMgnt 12 }
+ iesSysMulticastGroup OBJECT IDENTIFIER ::= { iesSysMgnt 13 }
+ iesSysIgmpFilter OBJECT IDENTIFIER ::= { iesSysMgnt 14 }
+
+ iesL2SW OBJECT IDENTIFIER ::= { iesSeriesCommon 4 }
+
+ iesStats OBJECT IDENTIFIER ::= { iesSeriesCommon 5 }
+ iesMacStats OBJECT IDENTIFIER ::= { iesStats 1 }
+
+
+-- Chassis, slot information
+
+ iesNumOfChassis OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of chassis in the IES-2000/3000 system"
+ ::= { iesChassis 1 }
+
+ iesChassisTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesChassisEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table which contains the chassis information in IES-2000/3000
+ system"
+ ::= { iesChassis 2 }
+
+ iesChassisEntry OBJECT-TYPE
+ SYNTAX IesChassisEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { iesChassisId }
+ ::= { iesChassisTable 1 }
+
+ IesChassisEntry ::=
+ SEQUENCE {
+ iesChassisId INTEGER,
+ iesChassisFrameNumber INTEGER,
+ iesChassisSerialNumber DisplayString,
+ iesChassisNumber INTEGER,
+ iesChassisStatus INTEGER
+ }
+
+ iesChassisId OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Chassis ID"
+ ::= { iesChassisEntry 1 }
+
+ iesChassisFrameNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Frame ID"
+ ::= { iesChassisEntry 2 }
+
+
+ iesChassisSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Chassis Serial Number"
+ ::= { iesChassisEntry 3 }
+
+ iesChassisNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The Chassis Number which is defined by the system administrator
+ for management purpose"
+ ::= { iesChassisEntry 4 }
+
+ iesChassisStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ empty(1),
+ up(2),
+ down(3),
+ testing(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current status of the chassis."
+ ::= { iesChassisEntry 5 }
+
+ iesSlotTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesSlotEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table which contains the slot information in a chassis of
+ IES-2000/3000 system"
+ ::= { iesChassis 3 }
+
+ iesSlotEntry OBJECT-TYPE
+ SYNTAX IesSlotEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { iesChassisId, iesSlotId }
+ ::= { iesSlotTable 1 }
+
+ IesSlotEntry ::=
+ SEQUENCE {
+ iesSlotId INTEGER,
+ iesSlotModuleType INTEGER,
+ iesSlotModuleDescr DisplayString,
+ iesSlotModuleFWVersion DisplayString,
+ iesSlotModuleDriverVersion DisplayString,
+ iesSlotModuleModemCodeVersion DisplayString,
+ iesSlotModuleStatus INTEGER,
+ iesSlotModuleAlarmStatus INTEGER
+ }
+
+ iesSlotId OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Identity of the slot"
+ ::= { iesSlotEntry 1 }
+
+ iesSlotModuleType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ msc1000-L2(2),
+ msc1000-ML(3),
+ alc1024-61(4),
+ vlc1012(5),
+ slc1024(6),
+ alc1024-63(7),
+ msc1000A(8),
+ vlc1124(9),
+ alc1224-71(10),
+ alc1224-73(11),
+ slc1224-22(12),
+ alc1224-51(13),
+ alc1224-53(14)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Card type of the plug-in card in IES-2000/3000."
+ ::= { iesSlotEntry 2 }
+
+ iesSlotModuleDescr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The descriptions of the plug-in card in IES-2000/3000."
+ ::= { iesSlotEntry 3 }
+
+
+ iesSlotModuleFWVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The firmware version of the plug-in card in IES-2000/3000."
+ ::= { iesSlotEntry 4 }
+
+ iesSlotModuleDriverVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The DSL driver of the plug-in card in IES-2000/3000."
+ ::= { iesSlotEntry 5 }
+
+ iesSlotModuleModemCodeVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The DSL modem code version of the plug-in card in IES-2000/3000"
+ ::= { iesSlotEntry 6 }
+
+
+ iesSlotModuleStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ empty(1),
+ up(2),
+ down(3),
+ testing(4),
+ standby(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The module state of the plug-in card in IES-2000/3000"
+ ::= { iesSlotEntry 7 }
+
+ iesSlotModuleAlarmStatus OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates the alarm status of the module.
+ It is a bit map represented as a sum, therefore, it can represent
+ multiple defects simultaneously. The moduleNoDefect should be set
+ if and only if no other flag is set.
+
+ The various bit positions are:
+ 1 moduleNoDefect
+ 2 moduleOverHeat
+ 3 moduleFanRpmLow
+ 4 moduleVoltageLow
+ 5 moduleThermalSensorFailure
+ 6 modulePullOut
+ 7 powerDC48VAFailure
+ 8 powerDC48VBFailure
+ 9 extAlarmInputTrigger
+ 10 moduleDown
+ 11 mscSwitchOverOK
+ 12 networkTopologyChange"
+ ::= { iesSlotEntry 8 }
+
+
+
+ iesMscPortConfTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesMscPortConfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table contains port configuration information in MSC1000."
+ ::= { iesChassis 4 }
+
+ iesMscPortConfEntry OBJECT-TYPE
+ SYNTAX IesMscPortConfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ ""
+ INDEX { iesChassisId,iesSlotId,iesMscPortId }
+ ::= { iesMscPortConfTable 1}
+
+ IesMscPortConfEntry ::=
+ SEQUENCE {
+ iesMscPortId INTEGER,
+ iesMscPortType INTEGER,
+ iesMscPortIfIndex INTEGER,
+ iesMscPortSpeed INTEGER,
+ iesMscPortDuplex INTEGER,
+ iesMscPortFlowControl INTEGER,
+ iesMscPortDefaultVLANTagging INTEGER,
+ iesMscPortTrunkGroupId INTEGER,
+ iesMscPortMode INTEGER,
+ iesMscPortVLANTrunking INTEGER
+ }
+
+ iesMscPortId OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Identity of the extension slot in MSC1000."
+ ::= { iesMscPortConfEntry 1 }
+
+ iesMscPortType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ e1000BaseT(2),
+ e1000BaseLX(3),
+ e1000BaseSX(4),
+ e100BaseFX(5),
+ e100BaseTX(6),
+ e1000BaseGBIC(7)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Port type of the extension slot in MSC1000."
+ ::= { iesMscPortConfEntry 2 }
+
+ iesMscPortIfIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { iesMscPortConfEntry 3 }
+
+ iesMscPortSpeed OBJECT-TYPE
+ SYNTAX INTEGER {
+ auto(1),
+ e1000M(2),
+ e100M(3),
+ e10M(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { iesMscPortConfEntry 4 }
+
+ iesMscPortDuplex OBJECT-TYPE
+ SYNTAX INTEGER {
+ full(1),
+ half(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { iesMscPortConfEntry 5 }
+
+ iesMscPortFlowControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ true(1),
+ false(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { iesMscPortConfEntry 6 }
+
+ iesMscPortDefaultVLANTagging OBJECT-TYPE
+ SYNTAX INTEGER {
+ true(1),
+ false(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { iesMscPortConfEntry 7 }
+
+ iesMscPortTrunkGroupId OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { iesMscPortConfEntry 8 }
+
+ iesMscPortMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ uplink(1),
+ subtending(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ " The operational mode for uplink and subtending ports in MSC. Only
+ the operational mode of subtending ports can be modified."
+ ::= { iesMscPortConfEntry 9 }
+
+ iesMscPortVLANTrunking OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ " The VLAN trunking setting for uplink and subtending ports in MSC."
+ ::= { iesMscPortConfEntry 10 }
+
+
+
+-- System Hardware Monitoring
+
+-- Fan rpm table
+
+ iesFanRpmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesFanRpmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains rpm information about the fans."
+ ::= { iesHWMonitor 1 }
+
+ iesFanRpmEntry OBJECT-TYPE
+ SYNTAX IesFanRpmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of rpm information for each fan."
+ INDEX { iesChassisId,iesFanRpmIndex }
+ ::= { iesFanRpmTable 1 }
+
+ IesFanRpmEntry ::=
+ SEQUENCE {
+ iesFanRpmIndex INTEGER,
+ iesFanRpmCurValue INTEGER,
+ iesFanRpmMaxValue INTEGER,
+ iesFanRpmMinValue INTEGER,
+ iesFanRpmLowThresh INTEGER,
+ iesFanRpmDescr DisplayString
+ }
+
+ iesFanRpmIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The identity of the fan."
+ ::= { iesFanRpmEntry 1 }
+
+ iesFanRpmCurValue OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current rpm of the fan."
+ ::= { iesFanRpmEntry 2 }
+
+ iesFanRpmMaxValue OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum rpm ever performed by the fan."
+ ::= { iesFanRpmEntry 3 }
+
+ iesFanRpmMinValue OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum rpm ever performed by the fan."
+ ::= { iesFanRpmEntry 4 }
+
+ iesFanRpmLowThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The low threshold of the rpm of the fan. If the current rpm is less than
+ the threshold, the device will initiate the fanRpmLow trap."
+ ::= { iesFanRpmEntry 5 }
+
+ iesFanRpmDescr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The description of the fan (e.g. location, function, etc.)."
+ ::= { iesFanRpmEntry 6 }
+
+
+
+-- Voltage table
+
+ iesVoltageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesVoltageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains voltage information about the system."
+ ::= { iesHWMonitor 2 }
+
+ iesVoltageEntry OBJECT-TYPE
+ SYNTAX IesVoltageEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of voltage information for each sensor."
+ INDEX { iesChassisId,iesSlotId,iesVoltageIndex }
+ ::= { iesVoltageTable 1 }
+
+ IesVoltageEntry ::=
+ SEQUENCE {
+ iesVoltageIndex INTEGER,
+ iesVoltageCurValue INTEGER,
+ iesVoltageMaxValue INTEGER,
+ iesVoltageMinValue INTEGER,
+ iesVoltageNominalValue INTEGER,
+ iesVoltageLowThresh INTEGER,
+ iesVoltageDescr DisplayString
+ }
+
+ iesVoltageIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The identity of the sensor."
+ ::= { iesVoltageEntry 1 }
+
+ iesVoltageCurValue OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current voltage detected by the sensor (in milli-voltage)."
+ ::= { iesVoltageEntry 2 }
+
+ iesVoltageMaxValue OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum voltage ever detected by the sensor (in milli-voltage)."
+ ::= { iesVoltageEntry 3 }
+
+ iesVoltageMinValue OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum voltage ever detected by the sensor (in milli-voltage)."
+ ::= { iesVoltageEntry 4 }
+
+ iesVoltageNominalValue OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The nominal voltage which the power should supply (in milli-voltage)."
+ ::= { iesVoltageEntry 5 }
+
+ iesVoltageLowThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The low threshold of the voltage (in milli-voltage). If the current voltage
+ is less than the threshold, the device will initiate the voltageLow trap."
+ ::= { iesVoltageEntry 6 }
+
+ iesVoltageDescr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The description of the voltage (e.g. location, nominal value, etc.)."
+ ::= { iesVoltageEntry 7 }
+
+
+
+-- System temperature table
+
+ iesSysTempTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesSysTempEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains temperature information about system."
+ ::= { iesHWMonitor 3 }
+
+ iesSysTempEntry OBJECT-TYPE
+ SYNTAX IesSysTempEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of temperature information for each sensor."
+ INDEX { iesChassisId,iesSlotId,iesSysTempIndex }
+ ::= { iesSysTempTable 1 }
+
+ IesSysTempEntry ::=
+ SEQUENCE {
+ iesSysTempIndex INTEGER,
+ iesSysTempCurValue INTEGER,
+ iesSysTempMaxValue INTEGER,
+ iesSysTempMinValue INTEGER,
+ iesSysTempHighThresh INTEGER,
+ iesSysTempDescr DisplayString
+ }
+
+ iesSysTempIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The identity of the sensor."
+ ::= { iesSysTempEntry 1 }
+
+ iesSysTempCurValue OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current temperature detected in Celsius by the sensor."
+ ::= { iesSysTempEntry 2 }
+
+ iesSysTempMaxValue OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum temperature ever detected in Celsius by the sensor."
+ ::= { iesSysTempEntry 3 }
+
+ iesSysTempMinValue OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The minimum temperature ever detected in Celsius by the sensor."
+ ::= { iesSysTempEntry 4 }
+
+ iesSysTempHighThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The high threshold of the temperature in Celsius. If the current temperature
+ is higher than the threshold, the device will initiate the overheat trap."
+ ::= { iesSysTempEntry 5 }
+
+ iesSysTempDescr OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The description of the temperature sensor (e.g. location, function, etc.)."
+ ::= { iesSysTempEntry 6 }
+
+
+
+-- System Management
+
+ -- System Status
+
+ iesSystemCurrentStatus OBJECT-TYPE
+ SYNTAX INTEGER(0..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION "This variable indicates the status of the system.
+ The sysCurrentStatus is a bit map represented
+ as a sum, therefore, it can represent multiple defects
+ simultaneously. The sysNoDefect should be set if and only if
+ no other flag is set.
+
+ The various bit positions are:
+ 1 sysNoDefect
+ 2 sysTemperatureAbnormal
+ 3 sysFanRpmAbnormal
+ 4 sysVoltageAbnormal
+ 5 sysThermalSensorFailure
+ 6 modulePullOut
+ 7 powerDC48VAFailure
+ 8 powerDC48VBFailure
+ 9 extAlarmInputTrigger
+ 10 moduleDown
+ 11 mscSwitchOverOK
+ 12 networkTopologyChange"
+
+ ::= {iesSysState 1 }
+
+ iesProblemCause OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "It describes the problem occurred in the system, e.g. maintenance
+ operation failures, system reboot, error log, ...etc."
+ ::= { iesSysState 2 }
+
+
+
+-- System Maintenance
+
+ iesMaintenanceOps OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The managed object is for system maintenance. When the EMS
+ wants to trigger the system maitenance operation, the EMS
+ shall send SNMP-SET message to set the corresponding bit value
+ to be 1. The various bit positions are:
+ BIT 1: config save
+ BIT 2: reset
+ BIT 3: local loopback test
+ BIT 4: remote loopback test
+ BIT 5: clear system alarms
+ BIT 6: F4 loopback test
+ BIT 7: F5 loopback test
+ BIT 8: DSL Line Diagnostic"
+ ::= { iesSysMaintenance 1 }
+
+ iesMaintenanceTarget OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The managed object is used for identify the target on which
+ the maintenance operation should be performed. The target can
+ be a chassis, a plug-in module, and a port.
+ The value of the object will be:
+ (Chassisid * 10000 + slotid * 100 + portid)
+ where
+ chassisid: 0~3,
+ slotid: 1~16,
+ portid: 1~24"
+ ::= { iesSysMaintenance 2 }
+
+
+-- variables for provisioning DSL line in batch mode
+
+ iesMaintenanceDSLConfOps OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The managed object is for xDSL line configuration. When the EMS
+ wants to issue the desired operation, the EMS
+ shall send SNMP-SET message to set the corresponding bit value
+ to be 1. The various bit positions are:
+ BIT 1: enable port
+ BIT 2: disable port
+ BIT 3: set DSL mode
+ BIT 4: set profile
+ BIT 5: enable mac filter
+ BIT 6: disable mac filter
+ BIT 7: set packet filter
+ BIT 8: enable dot1x
+ BIT 9: disable dot1x
+ BIT 10: set dot1x control
+ BIT 11: enable dot1x re-authentication
+ BIT 12: disable dot1x re-authentication
+ BIT 13: set dot1x re-authentication period
+ BIT 14: enable mac count filter
+ BIT 15: disable mac count filter
+ BIT 16: set mac count filter
+ BIT 17: set alarm profile
+ BIT 18: set Annex L (Only in AnnexA)
+ BIT 19: set power management
+ BIT 20: set rate adaptation mode
+ BIT 21: set IGMP filter
+ BIT 22: enable Annex M
+ BIT 23: disable Annex M"
+ ::= { iesSysMaintenance 3 }
+
+ iesMaintenanceDSLConfTarget OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The managed object is used for identify the target on which
+ the line configuration should be performed. The target is encoded
+ as:
+ Byte 1: the octet specifies a set of eight Chassis, Chassis 0 through 7
+ Byte 2~3: each octet specifies a set of eight slots, with the
+ first octet specifying slots 1 through 8 and the second
+ octet specifying slots 9 through 16.
+ Byte 4: reserved
+ Byte 5~11: each octet specifies a set of eight ports, with the first
+ octet specifying ports 1 through 8, etc."
+ ::= { iesSysMaintenance 4 }
+
+ iesMaintenanceDSLConfProfileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..31))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The DSL profile name"
+ ::= { iesSysMaintenance 5 }
+
+ iesMaintenanceDSLConfMode OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The DSL mode. The semantic for each bit is:
+ Bit 1: ADSL, G.lite
+ Bit 2: ADSL, G.dmt
+ Bit 3: ADSL, T1.413
+ Bit 4: ADSL, Auto
+ Bit 5: ADSL, ETSI
+ Bit 6: ADSL2,
+ Bit 7: ADSL2+"
+ ::= { iesSysMaintenance 6 }
+
+ iesMaintenanceDSLConfPktFilter OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The packet filter. The semantic for each bit is:
+ Bit 1: accept all
+ Bit 2: accept PPPoE only
+ Bit 3: reject ARP
+ Bit 4: reject DHCP
+ Bit 5: reject EAPOL
+ Bit 6: reject PPPoE
+ Bit 7: reject NetBIOS
+ Bit 8: reject IGMP
+ Bit 9: reject IP"
+ ::= { iesSysMaintenance 7 }
+
+ iesMaintenanceDSLConfDot1xControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ auto(1),
+ forceAuth(2),
+ forceUnAuth(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The configuration defines the 802.1x control type."
+ ::= { iesSysMaintenance 8 }
+
+ iesMaintenanceDSLConfDot1xReauthPeriod OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The configuration defines the 802.1x re-authentication period (seconds)."
+ ::= { iesSysMaintenance 9 }
+
+ iesMaintenanceDSLConfMacCount OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The configuration defines the number of mac addresses which can pass through the port."
+ ::= { iesSysMaintenance 10 }
+
+ iesMaintenanceVpi OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "VPI of the channel"
+ ::= { iesSysMaintenance 11 }
+
+ iesMaintenanceVci OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "VCI of the channel"
+ ::= { iesSysMaintenance 12 }
+
+ iesMaintenanceDSLConfAlarmProfileName OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..31))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The DSL alarm profile name"
+ ::= { iesSysMaintenance 13 }
+
+ iesMaintenanceDSLConfAnnexL OBJECT-TYPE
+ SYNTAX INTEGER {
+ enableNarrowMode(1),
+ enableWideMode(2),
+ disable(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The annex L setting of the ADSL line (Only in AnnexA)."
+ ::= { iesSysMaintenance 14 }
+
+ iesMaintenanceDSLConfPmMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ enableL2Mode(1),
+ enableL3Mode(2),
+ disable(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The power management mode of the ADSL line."
+ ::= { iesSysMaintenance 15 }
+
+ iesMaintenanceDSLConfRateMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ fixed(1), -- no rate adaptation
+ adaptAtStartup(2), -- perform rate adaptation
+ -- only at initialization
+ adaptAtRuntime(3) -- perform rate adaptation at
+ -- any time
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines what form of transmit rate adaptation is
+ configured on this modem. See ADSL Forum TR-005 [3]
+ for more information."
+ ::= { iesSysMaintenance 16 }
+
+ iesMaintenanceDSLConfIgmpFilter OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..31))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IGMP filter name."
+ ::= { iesSysMaintenance 17 }
+
+
+ -- System Time Setup
+
+ iesTimeServerMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ daytime(2),
+ time(3),
+ ntp(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The mechanism of Time Server when the system boots up."
+ ::= { iesSysTimeSetup 1 }
+
+ iesTimeServerIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IP Address of Time Server"
+ ::= { iesSysTimeSetup 2 }
+
+ iesSystemTime OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system time"
+ ::= { iesSysTimeSetup 3 }
+
+ iesSystemDate OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system date"
+ ::= { iesSysTimeSetup 4 }
+
+ iesSystemTimeZone OBJECT-TYPE
+ SYNTAX INTEGER {
+ utc-1200(1),
+ utc-1100(2),
+ utc-1000(3),
+ utc-0900(4),
+ utc-0800(5),
+ utc-0700(6),
+ utc-0600(7),
+ utc-0500(8),
+ utc-0400(9),
+ utc-0300(10),
+ utc-0200(11),
+ utc-0100(12),
+ utc(13),
+ utc0100(14),
+ utc0200(15),
+ utc0300(16),
+ utc0400(17),
+ utc0500(18),
+ utc0600(19),
+ utc0700(20),
+ utc0800(21),
+ utc0900(22),
+ utc1000(23),
+ utc1100(24),
+ utc1200(25)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The system time zone"
+ ::= { iesSysTimeSetup 5 }
+
+
+
+-- System Access Control
+
+ iesAccessCtrlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesAccessCtrlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains information about service access control."
+ ::= { iesSysAccessControl 1 }
+
+ iesAccessCtrlEntry OBJECT-TYPE
+ SYNTAX IesAccessCtrlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of access control entry."
+ INDEX { iesAccessCtrlService }
+ ::= { iesAccessCtrlTable 1 }
+
+ IesAccessCtrlEntry ::=
+ SEQUENCE {
+ iesAccessCtrlService INTEGER,
+ iesAccessCtrlEnable INTEGER,
+ iesAccessCtrlPort INTEGER
+ }
+
+ iesAccessCtrlService OBJECT-TYPE
+ SYNTAX INTEGER {
+ telnet(1),
+ ftp(2),
+ web(3),
+ icmp(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The service type of the access control entry."
+ ::= { iesAccessCtrlEntry 1 }
+
+ iesAccessCtrlEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable or disable the service."
+ ::= { iesAccessCtrlEntry 2 }
+
+ iesAccessCtrlPort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The port number which the service uses."
+ ::= { iesAccessCtrlEntry 3 }
+
+ -- secured client table
+ iesMaxNumOfSecuredClients OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of sets of secured clients."
+ ::= { iesSysAccessControl 2}
+
+ iesSecuredClientTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesSecuredClientEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains information about secured clients."
+ ::= { iesSysAccessControl 3 }
+
+ iesSecuredClientEntry OBJECT-TYPE
+ SYNTAX IesSecuredClientEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of secured client entry."
+ INDEX { iesSecuredClientStartIp, iesSecuredClientEndIp }
+ ::= { iesSecuredClientTable 1 }
+
+ IesSecuredClientEntry ::=
+ SEQUENCE {
+ iesSecuredClientStartIp IpAddress,
+ iesSecuredClientEndIp IpAddress,
+ iesSecuredClientService INTEGER,
+ iesSecuredClientRowStatus RowStatus
+ }
+
+ iesSecuredClientStartIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The starting IP address of a set of secured clients."
+ ::= { iesSecuredClientEntry 1 }
+
+ iesSecuredClientEndIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ending IP address of a set of secured clients."
+ ::= { iesSecuredClientEntry 2 }
+
+ iesSecuredClientService OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Each bit corresponds to a service. The bit is set to 1 if the
+ service is enabled, and set to 0 if the service is disabled.
+ The various bit positions are:
+ BIT 1: telnet
+ BIT 2: FTP
+ BIT 3: web
+ BIT 4: ICMP"
+ ::= { iesSecuredClientEntry 3 }
+
+ iesSecuredClientRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object is used to create a new row or modify or delete an existing row
+ in this table. A row is activated by setting this object to `active', and is
+ deactivated by setting it to 'notInService'."
+ ::= { iesSecuredClientEntry 4 }
+
+
+
+-- Static Route
+
+ iesMaxNumOfStaticRoutes OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of static routes."
+ ::= { iesSysStaticRoute 1 }
+
+ iesStaticRouteTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesStaticRouteEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains information about static routes."
+ ::= { iesSysStaticRoute 2 }
+
+ iesStaticRouteEntry OBJECT-TYPE
+ SYNTAX IesStaticRouteEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of static route entry."
+ INDEX { iesStaticRouteName }
+ ::= { iesStaticRouteTable 1 }
+
+ IesStaticRouteEntry ::=
+ SEQUENCE {
+ iesStaticRouteName DisplayString,
+ iesStaticRouteDest IpAddress,
+ iesStaticRouteMask IpAddress,
+ iesStaticRouteGateway IpAddress,
+ iesStaticRouteMetric INTEGER,
+ iesStaticRouteRowStatus RowStatus
+ }
+
+ iesStaticRouteName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The name of the static route."
+ ::= { iesStaticRouteEntry 1 }
+
+ iesStaticRouteDest OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The destination IP address of the static route."
+ ::= { iesStaticRouteEntry 2 }
+
+ iesStaticRouteMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The subnet mask of the static route."
+ ::= { iesStaticRouteEntry 3 }
+
+ iesStaticRouteGateway OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The gateway IP address of the static route."
+ ::= { iesStaticRouteEntry 4 }
+
+ iesStaticRouteMetric OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The routing metric of the static route."
+ ::= { iesStaticRouteEntry 5 }
+
+ iesStaticRouteRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object is used to create a new row or modify or delete an existing row
+ in this table. A row is activated by setting this object to `active', and is
+ deactivated by setting it to 'notInService'."
+ ::= { iesStaticRouteEntry 6 }
+
+
+
+-- syslog
+
+ iesSysLogEnable OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disable syslog function."
+ ::= { iesSyslogSetup 1 }
+
+ iesSysLogServer OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "IP address of the syslog server."
+ ::= { iesSyslogSetup 2 }
+
+ iesSysLogFacility OBJECT-TYPE
+ SYNTAX INTEGER {
+ local1(1),
+ local2(2),
+ local3(3),
+ local4(4),
+ local5(5),
+ local6(6),
+ local7(7)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Log facility used by the syslog function."
+ ::= { iesSyslogSetup 3 }
+
+
+
+-- DHCP Setup
+
+ iesDhcpRelayEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disable DHCP relay function."
+ ::= { iesSysDhcpSetup 1 }
+
+ iesDhcpRelayOption82Enable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disable DHCP relay Option82 function."
+ ::= { iesSysDhcpSetup 2 }
+
+ iesDhcpRelayOption82Info OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "User specific Option82 information."
+ ::= { iesSysDhcpSetup 3 }
+
+ iesMaxNumOfDhcpServers OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of DHCP servers."
+ ::= { iesSysDhcpSetup 4 }
+
+ iesDhcpServerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesDhcpServerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains DHCP server information."
+ ::= { iesSysDhcpSetup 5 }
+
+ iesDhcpServerEntry OBJECT-TYPE
+ SYNTAX IesDhcpServerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The entry of DHCP server table."
+ INDEX { iesDhcpServerIp }
+ ::= { iesDhcpServerTable 1 }
+
+ IesDhcpServerEntry ::=
+ SEQUENCE {
+ iesDhcpServerIp IpAddress,
+ iesDhcpServerRowStatus RowStatus
+ }
+
+ iesDhcpServerIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The IP address of the DHCP server."
+ ::= { iesDhcpServerEntry 1 }
+
+ iesDhcpServerRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The row status of the DHCP server entry."
+ ::= { iesDhcpServerEntry 2 }
+
+
+
+-- SNMP setup, Trap Destination
+
+ iesMaxNumberOfTrapDestinations OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The max number of the trap destinations."
+ ::= { iesSysSNMPSetup 1 }
+
+ iesSNMPTrapDestTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesSNMPTrapDestEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains SNMP trap destination information."
+ ::= { iesSysSNMPSetup 2 }
+
+ iesSNMPTrapDestEntry OBJECT-TYPE
+ SYNTAX IesSNMPTrapDestEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The entry of SNMP trap destination table."
+ INDEX { iesTrapDestIp, iesTrapDestPort }
+ ::= { iesSNMPTrapDestTable 1 }
+
+ IesSNMPTrapDestEntry ::=
+ SEQUENCE {
+ iesTrapDestIp IpAddress,
+ iesTrapDestPort INTEGER,
+ iesTrapDestRowStatus RowStatus
+ }
+
+ iesTrapDestIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The IP address of the trap destination."
+ ::= { iesSNMPTrapDestEntry 1 }
+
+ iesTrapDestPort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The UDP port of the trap destination."
+ ::= { iesSNMPTrapDestEntry 2 }
+
+ iesTrapDestRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The row status of the trap destination entry."
+ ::= { iesSNMPTrapDestEntry 3}
+
+ iesSnmpGetCommunity OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The SNMP get community."
+ ::= { iesSysSNMPSetup 3 }
+
+ iesSnmpSetCommunity OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The SNMP set community."
+ ::= { iesSysSNMPSetup 4 }
+
+ iesSnmpTrapCommunity OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap community."
+ ::= { iesSysSNMPSetup 5 }
+
+
+-- RADIUS Server setup
+
+ iesMaxNumberOfRadiusServers OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The max number of the RADIUS Servers."
+ ::= { iesSysDot1xSetup 1 }
+
+ iesRadiusServerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesRadiusServerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains Radius Server information."
+ ::= { iesSysDot1xSetup 2 }
+
+ iesRadiusServerEntry OBJECT-TYPE
+ SYNTAX IesRadiusServerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The entry of Radius Server table."
+ INDEX { iesRadiusServerIndex }
+ ::= { iesRadiusServerTable 1 }
+
+ IesRadiusServerEntry ::=
+ SEQUENCE {
+ iesRadiusServerIndex INTEGER,
+ iesRadiusServerIp IpAddress,
+ iesRadiusServerPort INTEGER,
+ iesRadiusSharedSecret DisplayString,
+ iesRadiusServerRowStatus RowStatus
+ }
+
+ iesRadiusServerIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The identity of the RADIUS server."
+ ::= { iesRadiusServerEntry 1 }
+
+ iesRadiusServerIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The IP address of the Radius Server."
+ ::= { iesRadiusServerEntry 2 }
+
+ iesRadiusServerPort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The UDP port of the Radius Server."
+ ::= { iesRadiusServerEntry 3 }
+
+ iesRadiusSharedSecret OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The shared secret of the Radius Server."
+ ::= { iesRadiusServerEntry 4 }
+
+ iesRadiusServerRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The row status of the Radius Server entry."
+ ::= { iesRadiusServerEntry 5 }
+
+
+-- 802.1x option
+
+ iesDot1xEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/disable the 802.1x function."
+ ::= { iesSysDot1xSetup 3 }
+
+
+
+-- 802.1x Table
+
+ iesDot1xPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesDot1xPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table includes the configuration of 802.1x."
+ ::= { iesSysDot1xSetup 4 }
+
+ iesDot1xPortEntry OBJECT-TYPE
+ SYNTAX IesDot1xPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in iesDot1xPortTable."
+ INDEX { ifIndex }
+ ::= { iesDot1xPortTable 1 }
+
+ IesDot1xPortEntry ::=
+ SEQUENCE {
+ iesDot1xPortEnable INTEGER,
+ iesDot1xPortControl INTEGER,
+ iesDot1xPortReAuthEnable INTEGER,
+ iesDot1xPortReAuthPeriod INTEGER
+ }
+
+ iesDot1xPortEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The option defines if the port enables 802.1x
+ settings."
+ ::= { iesDot1xPortEntry 1 }
+
+ iesDot1xPortControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ auto(1),
+ forceAuth(2),
+ forceUnAuth(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The configuration defines the 802.1x port control
+ type."
+ ::= { iesDot1xPortEntry 2 }
+
+ iesDot1xPortReAuthEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The option defines if the port enables 802.1x
+ re-authentication."
+ ::= { iesDot1xPortEntry 3 }
+
+ iesDot1xPortReAuthPeriod OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The configuration defines the 802.1x
+ re-authentication period (seconds) for each port."
+ ::= { iesDot1xPortEntry 4 }
+
+
+
+-- Mac Filter
+
+ iesMacFilterStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesMacFilterStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table includes the status of mac filtering for each port."
+ ::= { iesSysMacFilter 1 }
+
+ iesMacFilterStatusEntry OBJECT-TYPE
+ SYNTAX IesMacFilterStatusEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in iesMacFilterStatusTable."
+ INDEX { ifIndex }
+ ::= { iesMacFilterStatusTable 1 }
+
+ IesMacFilterStatusEntry ::=
+ SEQUENCE {
+ iesMacFilterStatusEnable INTEGER
+ }
+
+ iesMacFilterStatusEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enableaccept(1),
+ disable(2),
+ enabledeny(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The option defines if the port enables mac filtering."
+ ::= { iesMacFilterStatusEntry 1 }
+
+ iesMaxNumberOfMacFilters OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The max number of the mac filters in the system."
+ ::= { iesSysMacFilter 2 }
+
+ iesMaxNumberOfMacFiltersPerPort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The max number of the mac filters for each port."
+ ::= { iesSysMacFilter 3 }
+
+ iesCurrNumberOfMacFilters OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current number of the mac filters in the system."
+ ::= { iesSysMacFilter 4 }
+
+ iesMacFilterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesMacFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains the mac filtering information."
+ ::= { iesSysMacFilter 5 }
+
+ iesMacFilterEntry OBJECT-TYPE
+ SYNTAX IesMacFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The entry of iesMacFilterTable."
+ INDEX { ifIndex, iesMacFilterMacAddr }
+ ::= { iesMacFilterTable 1 }
+
+ IesMacFilterEntry ::=
+ SEQUENCE {
+ iesMacFilterMacAddr PhysAddress,
+ iesMacFilterRowStatus RowStatus
+ }
+
+ iesMacFilterMacAddr OBJECT-TYPE
+ SYNTAX PhysAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The mac address which can pass through the port."
+ ::= { iesMacFilterEntry 1 }
+
+ iesMacFilterRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The row status of the entry."
+ ::= { iesMacFilterEntry 2 }
+
+
+
+-- Packet Filter
+
+ iesPacketFilterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesPacketFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table includes packet filtering for each port."
+ ::= { iesSysPacketFilter 1 }
+
+ iesPacketFilterEntry OBJECT-TYPE
+ SYNTAX IesPacketFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in iesPacketFilterTable."
+ INDEX { ifIndex }
+ ::= { iesPacketFilterTable 1 }
+
+ IesPacketFilterEntry ::=
+ SEQUENCE {
+ iesPacketFilter INTEGER
+ }
+
+ iesPacketFilter OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The packet filter. The semantic for each bit is:
+ Bit 1: accept all
+ Bit 2: accept PPPoE only
+ Bit 3: reject ARP
+ Bit 4: reject DHCP
+ Bit 5: reject EAPOL
+ Bit 6: reject PPPoE
+ Bit 7: reject NetBIOS
+ Bit 8: reject IGMP
+ Bit 9: reject IP"
+ ::= { iesPacketFilterEntry 1 }
+
+
+
+-- Mac Count Filter
+
+ iesMacCountFilterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesMacCountFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table includes mac count filtering for each port."
+ ::= { iesSysMacCountFilter 1 }
+
+ iesMacCountFilterEntry OBJECT-TYPE
+ SYNTAX IesMacCountFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in iesMacCountFilterTable."
+ INDEX { ifIndex }
+ ::= { iesMacCountFilterTable 1 }
+
+ IesMacCountFilterEntry ::=
+ SEQUENCE {
+ iesMacCountFilterStatus INTEGER,
+ iesMacCountFilterCount INTEGER
+ }
+
+ iesMacCountFilterStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The option defines if the port enables mac count filtering."
+ ::= { iesMacCountFilterEntry 1 }
+
+ iesMacCountFilterCount OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The number of mac addresses which can pass through the port."
+ ::= { iesMacCountFilterEntry 2 }
+
+
+
+-- Static Multicast Group
+
+ iesMaxNumberOfMulticastGroups OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The max number of static multicast groups in the system."
+ ::= { iesSysMulticastGroup 1 }
+
+ iesMulticastGroupTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesMulticastGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains static multicast group information."
+ ::= { iesSysMulticastGroup 2 }
+
+ iesMulticastGroupEntry OBJECT-TYPE
+ SYNTAX IesMulticastGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The entry of multicast group table."
+ INDEX { iesMulticastGroupMacAddr }
+ ::= { iesMulticastGroupTable 1 }
+
+ IesMulticastGroupEntry ::=
+ SEQUENCE {
+ iesMulticastGroupMacAddr PhysAddress,
+ iesMulticastGroupPorts PortList,
+ iesMulticastGroupRowStatus RowStatus
+ }
+
+ iesMulticastGroupMacAddr OBJECT-TYPE
+ SYNTAX PhysAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The multicast MAC address of the group."
+ ::= { iesMulticastGroupEntry 1 }
+
+ iesMulticastGroupPorts OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The port list which specifies the ports joining the multicast group."
+ ::= { iesMulticastGroupEntry 2 }
+
+ iesMulticastGroupRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The row status of the multicast group entry."
+ ::= { iesMulticastGroupEntry 3 }
+
+
+-- IGMP Filter
+
+ iesMaxNumberOfIgmpFilters OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The max number of IGMP filters in the system."
+ ::= { iesSysIgmpFilter 1 }
+
+ iesIgmpFilterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesIgmpFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains IGMP filters."
+ ::= { iesSysIgmpFilter 2 }
+
+ iesIgmpFilterEntry OBJECT-TYPE
+ SYNTAX IesIgmpFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The entry of IGMP filter table."
+ INDEX { iesIgmpFilterName, iesIgmpFilterIndex }
+ ::= { iesIgmpFilterTable 1 }
+
+ IesIgmpFilterEntry ::=
+ SEQUENCE {
+ iesIgmpFilterName OCTET STRING,
+ iesIgmpFilterIndex INTEGER,
+ iesIgmpFilterStartIp IpAddress,
+ iesIgmpFilterEndIp IpAddress,
+ iesIgmpFilterRowStatus RowStatus
+ }
+
+ iesIgmpFilterName OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..31))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The IGMP filter name."
+ ::= { iesIgmpFilterEntry 1 }
+
+ iesIgmpFilterIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The index which specifies the filter rule."
+ ::= { iesIgmpFilterEntry 2 }
+
+ iesIgmpFilterStartIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The start IP of the filter rule."
+ ::= { iesIgmpFilterEntry 3 }
+
+ iesIgmpFilterEndIp OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The end IP of the filter rule."
+ ::= { iesIgmpFilterEntry 4 }
+
+ iesIgmpFilterRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The row status of the IGMP filter entry."
+ ::= { iesIgmpFilterEntry 5 }
+
+ iesIgmpFilterPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesIgmpFilterPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table specifies the IGMP filter of the port."
+ ::= { iesSysIgmpFilter 3 }
+
+ iesIgmpFilterPortEntry OBJECT-TYPE
+ SYNTAX IesIgmpFilterPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION "An entry in iesIgmpFilterPortTable."
+ INDEX { ifIndex }
+ ::= { iesIgmpFilterPortTable 1 }
+
+ IesIgmpFilterPortEntry ::=
+ SEQUENCE {
+ iesIgmpFilterPortFilter OCTET STRING
+ }
+
+ iesIgmpFilterPortFilter OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (1..31))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IGMP filter of the port."
+ ::= { iesIgmpFilterPortEntry 1 }
+
+
+-- L2 Switch Configuration
+
+ iesIGMPSnoopingEnabled OBJECT-TYPE
+ SYNTAX INTEGER {
+ true(1),
+ false(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A flag indicating whether IGMP snooping function is enabled or not."
+ ::= { iesL2SW 1 }
+
+ iesManagementVLANId OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The VLAN ID for management."
+ ::= { iesL2SW 2 }
+
+ iesMaxNumOfStaticVlans OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of static VLANs supported by the system."
+ ::= { iesL2SW 3 }
+
+ iesPortIsolationEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "A flag indicating whether VLAN port isolation function is enabled or not."
+ ::= { iesL2SW 6 }
+
+ iesRSTPEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enable(1),
+ disable(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Enable/Disable RSTP."
+ ::= { iesL2SW 7 }
+
+ iesSwitchMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ daisychain(1),
+ standalone(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Switch DSLAM's operatrion Mode."
+ ::= { iesL2SW 8 }
+
+
+ -- Trunk Group
+
+ iesMaxNumOfTrunkGroups OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of trunk groups."
+ ::= { iesL2SW 4}
+
+ iesTrunkGroupTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesTrunkGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains trunk group configuration."
+ ::= { iesL2SW 5 }
+
+ iesTrunkGroupEntry OBJECT-TYPE
+ SYNTAX IesTrunkGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The entry of trunk group table"
+ INDEX { iesTrunkGroupId }
+ ::= { iesTrunkGroupTable 1 }
+
+ IesTrunkGroupEntry ::=
+ SEQUENCE {
+ iesTrunkGroupId INTEGER,
+ iesTrunkGroupName DisplayString,
+ iesTrunkGroupPorts PortList,
+ iesTrunkGroupRowStatus RowStatus
+ }
+
+ iesTrunkGroupId OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The ID of the trunk group"
+ ::= { iesTrunkGroupEntry 1 }
+
+ iesTrunkGroupName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The name of the trunk group"
+ ::= { iesTrunkGroupEntry 2 }
+
+ iesTrunkGroupPorts OBJECT-TYPE
+ SYNTAX PortList
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The port list of the trunk group"
+ ::= { iesTrunkGroupEntry 3 }
+
+ iesTrunkGroupRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The row status of the trunk group entry"
+ ::= { iesTrunkGroupEntry 4 }
+
+--------------------
+-- Statistics
+--------------------
+
+ iesMacDisplayTarget OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This managed object is a filter used for identify the target from which
+ the MAC addresses are learned in macTable. The target could be:
+ 1: Subtending port 1
+ 2: Subtending port 2
+ 3: Uplink port 1
+ 4: Uplink port 2
+ 5: All of the four uplink ports
+ 6: All ports in the system
+ IfIndex is used for identifying subscriber ports (e.g. 300 means all ports in slot 3
+ and 301 means port 1 in slot 3)."
+ ::= { iesMacStats 1 }
+
+-- macTable
+
+ iesMacTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IesMacEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains information about unicast
+ entries for which the bridge has forwarding and/or
+ filtering information. This information is used
+ by the transparent bridging function in
+ determining how to propagate a received frame."
+ ::= { iesMacStats 2 }
+
+ iesMacEntry OBJECT-TYPE
+ SYNTAX IesMacEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry of iesMacTable."
+ INDEX { iesMacAddress }
+ ::= { iesMacTable 1 }
+
+ IesMacEntry ::=
+ SEQUENCE {
+ iesMacAddress MacAddress,
+ iesMacPort INTEGER,
+ iesMacStatus INTEGER
+ }
+
+ iesMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A unicast MAC address for which the bridge has
+ forwarding and/or filtering information."
+ ::= { iesMacEntry 1 }
+
+ iesMacPort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port from which the mac address has been learned."
+ ::= { iesMacEntry 2 }
+
+ iesMacStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ invalid(2),
+ learned(3),
+ self(4),
+ mgmt(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of this entry."
+ ::= { iesMacEntry 3 }
+
+
+-- Enterprise specific traps
+
+ reboot TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesProblemCause
+ }
+ DESCRIPTION "Send a message to the manager that the system is going to reboot.
+ The variable is the reason why the system reboots."
+ ::= 1
+
+ systemShutdown TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesProblemCause
+ }
+ DESCRIPTION "Send a message to the manager that the system is going to shutdown.
+ The variable is the reason that causes the system to shutdown."
+ ::= 2
+
+ overheat TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesChassisId,
+ iesSlotId,
+ iesSysTempIndex,
+ iesSysTempCurValue
+ }
+ DESCRIPTION "Send a message to the manager that the system is overheated.
+ The variable in the binding list is the current temperature in Celsius
+ of the system."
+ ::= 3
+
+ overheatOver TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesChassisId,
+ iesSlotId,
+ iesSysTempIndex,
+ iesSysTempCurValue
+ }
+ DESCRIPTION "Send a message to the manager that the overheated condition is over.
+ The variable in the binding list is the current temperature in Celsius
+ of the system."
+ ::= 4
+
+ errLog TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesProblemCause
+ }
+ DESCRIPTION "Send a message to the manager that an error log is created in system.
+ The variable in the binding list is the content of the error log."
+ ::= 5
+
+ fanRpmLow TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesChassisId,
+ iesFanRpmIndex,
+ iesFanRpmCurValue
+ }
+ DESCRIPTION "Send a message to the manager that the rpm of the fan is too low.
+ The variable in the binding list is the current rpm of the fan."
+ ::= 6
+
+ fanRpmNormal TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesChassisId,
+ iesFanRpmIndex,
+ iesFanRpmCurValue
+ }
+ DESCRIPTION "Send a message to the manager that the low-rpm condition of the fan is over.
+ The variable in the binding list is the current rpm of the fan."
+ ::= 7
+
+ voltageOutOfRange TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesChassisId,
+ iesSlotId,
+ iesVoltageIndex,
+ iesVoltageCurValue
+ }
+ DESCRIPTION "Send a message to the manager that the voltage of the system is out of range.
+ The variable in the binding list is the current voltage in volt
+ of the system."
+ ::= 8
+
+ voltageNormal TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesChassisId,
+ iesSlotId,
+ iesVoltageIndex,
+ iesVoltageCurValue
+ }
+ DESCRIPTION "Send a message to the manager that the low-voltage condition is over.
+ The variable in the binding list is the current voltage in volt
+ of the system."
+ ::= 9
+
+ systemMaintenanceFailure TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesChassisId,
+ iesSlotId,
+ iesProblemCause
+ }
+ DESCRIPTION "Send a message to the manager that the system maintence operation
+ fail. The variable in the variable binding indicates the problem."
+ ::= 10
+
+ configChange TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesChassisId,
+ iesSlotId,
+ iesProblemCause
+ }
+ DESCRIPTION "This notification indicates that the configuration data of one module is changed."
+ ::= 11
+
+ moduleUp TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesChassisId,
+ iesSlotId
+ }
+ DESCRIPTION "A moduleUp trap signifies that the sending
+ protocol entity recognizes that one of the
+ modules represented in the agent's
+ configuration has come up."
+ ::= 12
+
+ moduleDown TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesChassisId,
+ iesSlotId
+ }
+ DESCRIPTION "A moduleDown trap signifies that the sending
+ protocol entity recognizes a failure in one of
+ the modules represented in the agent's
+ configuration."
+ ::= 13
+
+ modulePlugIn TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesChassisId,
+ iesSlotId
+ }
+ DESCRIPTION "A modulePlugIn trap signifies that the sending
+ protocol entity recognizes that one module is
+ plugged into the device."
+ ::= 14
+
+ modulePullOut TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesChassisId,
+ iesSlotId
+ }
+ DESCRIPTION "A modulePullOut trap signifies that the sending
+ protocol entity recognizes one module is pulled out
+ from the device."
+ ::= 15
+
+ powerDC48VAFailure TRAP-TYPE
+ ENTERPRISE iesSeries
+-- VARIABLES {
+-- }
+ DESCRIPTION "The trap signifies that the power supply of DC 48V at the
+ right side of main Chassis (front view) failed."
+ ::= 16
+
+ powerDC48VANormal TRAP-TYPE
+ ENTERPRISE iesSeries
+-- VARIABLES {
+-- }
+ DESCRIPTION "The trap signifies that the power supply of DC 48V at the
+ right side of main Chassis (front view) is in normal state."
+ ::= 17
+
+ powerDC48VBFailure TRAP-TYPE
+ ENTERPRISE iesSeries
+-- VARIABLES {
+-- }
+ DESCRIPTION "The trap signifies that the power supply of DC 48V at the
+ left side of main Chassis (front view) failed."
+ ::= 18
+
+ powerDC48VBNormal TRAP-TYPE
+ ENTERPRISE iesSeries
+-- VARIABLES {
+-- }
+ DESCRIPTION "The trap signifies that the power supply of DC 48V at the
+ left side of main Chassis (front view) is in normal state."
+ ::= 19
+
+ extAlarmInputTrigger TRAP-TYPE
+ ENTERPRISE iesSeries
+-- VARIABLES {
+-- }
+ DESCRIPTION "The trap signifies that the external alarm input of MSC card
+ is triggered."
+ ::= 20
+
+ extAlarmInputRelease TRAP-TYPE
+ ENTERPRISE iesSeries
+-- VARIABLES {
+-- }
+ DESCRIPTION "The trap signifies that the external alarm input of MSC card
+ is released."
+ ::= 21
+
+ thermalSensorFailure TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesChassisId,
+ iesSlotId
+ }
+ DESCRIPTION "The trap signifies that the thermal sensor failed."
+ ::= 22
+
+
+
+ mscSwitchOverOK TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ iesChassisId,
+ iesSlotId
+ }
+ DESCRIPTION "The trap signifies that MSC card is switched over successfully. The value of
+ iesSlotId is the slot ID of the current working MSC."
+ ::= 23
+
+
+ networkTopologyChange TRAP-TYPE
+ ENTERPRISE iesSeries
+-- VARIABLES {
+-- }
+ DESCRIPTION "The trap signifies the network topology is changed."
+ ::= 24
+
+ adslAtucLof TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ ifIndex
+ }
+ DESCRIPTION "The trap signifies ATU-C Loss of Framing."
+ ::= 25
+
+ adslAturLof TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ ifIndex
+ }
+ DESCRIPTION "The trap signifies ATU-R Loss of Framing."
+ ::= 26
+
+ adslAtucLos TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ ifIndex
+ }
+ DESCRIPTION "The trap signifies ATU-C Loss of Signal."
+ ::= 27
+
+ adslAturLos TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ ifIndex
+ }
+ DESCRIPTION "The trap signifies ATU-R Loss of Signal."
+ ::= 28
+
+ adslAturLpr TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ ifIndex
+ }
+ DESCRIPTION "The trap signifies ATU-R Loss of Power."
+ ::= 29
+
+ adslAtucLofClear TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ ifIndex
+ }
+ DESCRIPTION "The trap signifies ATU-C Loss of Framing is cleared."
+ ::= 30
+
+ adslAturLofClear TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ ifIndex
+ }
+ DESCRIPTION "The trap signifies ATU-R Loss of Framing is cleared."
+ ::= 31
+
+ adslAtucLosClear TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ ifIndex
+ }
+ DESCRIPTION "The trap signifies ATU-C Loss of Signal is cleared."
+ ::= 32
+
+ adslAturLosClear TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ ifIndex
+ }
+ DESCRIPTION "The trap signifies ATU-R Loss of Signal is cleared."
+ ::= 33
+
+ adslAturLprClear TRAP-TYPE
+ ENTERPRISE iesSeries
+ VARIABLES {
+ ifIndex
+ }
+ DESCRIPTION "The trap signifies ATU-R Loss of Power is cleared."
+ ::= 34
+
+END