summaryrefslogtreecommitdiff
path: root/MIBS/XPPC-MIB
blob: 526a308559dc573dd69694fb7752431a98f96c8f (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
--PPC-MIB { iso(1) org(3) dod(6) internet(1) private(4)
-- enterprises(1) ppc(935) }
-- Title: PPC TOP LEVEL MIB
-- Date: January 07, 1994    Version 1.00
--
-- Date: January 17, 1994    Version 1.01
--
-- Date: July 14, 1994    Version 1.02
--
-- Date: May 16, 2003    Version 2.00

XPPC-MIB DEFINITIONS ::= BEGIN

IMPORTS
        TRAP-TYPE
                FROM RFC-1215
        DisplayString
                FROM RFC1213-MIB
        OBJECT-TYPE
                FROM RFC-1212
        enterprises,
        IpAddress
                FROM RFC1155-SMI;


ppc OBJECT IDENTIFIER 
   ::= { enterprises 935 }

products OBJECT IDENTIFIER 
   ::= { ppc 1 }

ppcmgmt OBJECT IDENTIFIER 
   ::= { ppc 2 }

hardware OBJECT IDENTIFIER 
   ::= { products 1 }

mconfig OBJECT IDENTIFIER 
   ::= { ppcmgmt 1 }

ups OBJECT IDENTIFIER 
   ::= { hardware 1 }

upsIdentp OBJECT IDENTIFIER 
   ::= { ups 1 }

upsBatteryp OBJECT IDENTIFIER 
   ::= { ups 2 }

upsInputp OBJECT IDENTIFIER 
   ::= { ups 3 }

upsOutputp OBJECT IDENTIFIER 
   ::= { ups 4 }

upsConfigp OBJECT IDENTIFIER 
   ::= { ups 5 }

upsControlp OBJECT IDENTIFIER 
   ::= { ups 6 }

upsTestp OBJECT IDENTIFIER 
   ::= { ups 7 }

upsThreePhase OBJECT IDENTIFIER 
   ::= { ups 8 }

upsEnvironment OBJECT IDENTIFIER 
   ::= { ups 9 }

upsBaseIdent OBJECT IDENTIFIER 
   ::= { upsIdentp 1 }

upsSmartIdent OBJECT IDENTIFIER 
   ::= { upsIdentp 2 }

upsBaseBattery OBJECT IDENTIFIER 
   ::= { upsBatteryp 1 }

upsSmartBattery OBJECT IDENTIFIER 
   ::= { upsBatteryp 2 }

upsBaseInput OBJECT IDENTIFIER 
   ::= { upsInputp 1 }

upsSmartInput OBJECT IDENTIFIER 
   ::= { upsInputp 2 }

upsBaseOutput OBJECT IDENTIFIER 
   ::= { upsOutputp 1 }

upsSmartOutput OBJECT IDENTIFIER 
   ::= { upsOutputp 2 }

upsBaseConfig OBJECT IDENTIFIER 
   ::= { upsConfigp 1 }

upsSmartConfig OBJECT IDENTIFIER 
   ::= { upsConfigp 2 }

upsBaseControl OBJECT IDENTIFIER 
   ::= { upsControlp 1 }

upsSmartControl OBJECT IDENTIFIER 
   ::= { upsControlp 2 }

upsBaseTest OBJECT IDENTIFIER 
   ::= { upsTestp 1 }

upsSmartTest OBJECT IDENTIFIER 
   ::= { upsTestp 2 }

upsThreePhaseBatteryGrp OBJECT IDENTIFIER 
   ::= { upsThreePhase 1 }

upsThreePhaseInputGrp OBJECT IDENTIFIER 
   ::= { upsThreePhase 2 }

upsThreePhaseOutputGrp OBJECT IDENTIFIER 
   ::= { upsThreePhase 3 }

upsThreePhaseBypassGrp OBJECT IDENTIFIER 
   ::= { upsThreePhase 4 }

upsThreePhaseDCandRectifierStatusGrp OBJECT IDENTIFIER 
   ::= { upsThreePhase 5 }

upsThreePhaseUPSStatusGrp OBJECT IDENTIFIER 
   ::= { upsThreePhase 6 }

upsThreePhaseFaultStatusGrp OBJECT IDENTIFIER 
   ::= { upsThreePhase 7 }

upsThreePhaseRatingGrp OBJECT IDENTIFIER 
   ::= { upsThreePhase 8 }

-- object types
-- the ppcmgmt group
-- the mconfig group

mconfigTrapsReceiversNum OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The number of managers to send traps to."
   ::= { mconfig 1 }


mconfigTrapsReceiversTable OBJECT-TYPE
        SYNTAX SEQUENCE OF MconfigTrapsReceiversEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list of managers to send traps to.  The number of
                entries is given by the value of mconfigNumTrapReceivers"
   ::= { mconfig 2 }


mconfigTrapsReceiversEntry OBJECT-TYPE
        SYNTAX MconfigTrapsReceiversEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The managers to send traps to."
        INDEX {
                trapsIndex }
   ::= { mconfigTrapsReceiversTable 1 }


MconfigTrapsReceiversEntry ::= SEQUENCE {
        trapsIndex              INTEGER,
        trapsReceiverAddr       IpAddress,
        receiverCommunityString DisplayString,
        severityLevel           INTEGER,
        receiverAccept          INTEGER }


trapsIndex OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to a trap receiver entry."
   ::= { mconfigTrapsReceiversEntry 1 }


trapsReceiverAddr OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The IP address of the manager to send a trap to."
   ::= { mconfigTrapsReceiversEntry 2 }


receiverCommunityString OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The community name to use in the trap when
                sent to the manager."
   ::= { mconfigTrapsReceiversEntry 3 }


severityLevel OBJECT-TYPE
        SYNTAX INTEGER {
                        information(1),
                        warning(2),
                        severe(3) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The severity threshold of traps to send to the manager.
                traps are labeled in severity as informational(1), warning(2),
                severe(3).  Only traps of equal or greater severity than
                this value are sent to the manager."
   ::= { mconfigTrapsReceiversEntry 4 }


receiverAccept OBJECT-TYPE
        SYNTAX INTEGER {
                        yes(1),
                        no(2) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "An entry will become active if yes, and will
                be deleted if no."
   ::= { mconfigTrapsReceiversEntry 5 }


-- the ups group
-- the upsBaseIdent group

upsBaseIdentModel OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The UPS model name (e.g. 'Intelligent 8000E 900VA')."
   ::= { upsBaseIdent 1 }


upsBaseIdentUpsName OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "An 8 byte ID string identifying the UPS.  This object
                can be set by the administrator."
   ::= { upsBaseIdent 2 }


-- the upsSmartIdent group

upsSmartIdentFirmwareRevision OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The firmware revision of the UPS system."
   ::= { upsSmartIdent 1 }


upsSmartIdentDateOfManufacture OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The date when the UPS was manufactured in mm/dd/yy format."
   ::= { upsSmartIdent 2 }


upsSmartIdentUpsSerialNumber OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "An 8-character string identifying the serial number of
                the UPS internal microprocessor.  This number is set at
                the factory.  NOTE: This number does NOT correspond to
                the serial number on the rear of the UPS."
   ::= { upsSmartIdent 3 }


upsSmartIdentAgentFirmwareRevision OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The firmware revision of the UPS SNMP Proxy agent."
   ::= { upsSmartIdent 4 }


-- the upsBaseBattery group

upsBaseBatteryStatus OBJECT-TYPE
        SYNTAX INTEGER {
                        unknown(1),
                        batteryNormal(2),
                        batteryLow(3) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The status of the UPS batteries.  A batteryLow(3)
                value indicates the UPS will be unable to sustain the
                current load, and its services will be lost if power is
                not restored.  The amount of run time in reserve at the
                time of low battery can be configured by the
                upsSmartConfigLowBatteryRunTime."
   ::= { upsBaseBattery 1 }


upsBaseBatteryTimeOnBattery OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The elapsed time in seconds since the UPS has switched
                to battery power."
   ::= { upsBaseBattery 2 }


upsBaseBatteryLastReplaceDate OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The date when the UPS system's batteries were last replaced
                in mm/dd/yy format.   For UPS models, this value is originally
                set in the factory.  When the UPS batteries are replaced,
                this value should be reset by the administrator."
   ::= { upsBaseBattery 3 }


-- the upsSmartBattery group

upsSmartBatteryCapacity OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The remaining battery capacity expressed in
                percent of full capacity."
   ::= { upsSmartBattery 1 }


upsSmartBatteryVoltage OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The current battery voltage expressed in 1/10 VDC."
   ::= { upsSmartBattery 2 }


upsSmartBatteryTemperature OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The current internal UPS temperature expressed in tenths of
                a Celsius degree."
   ::= { upsSmartBattery 3 }


upsSmartBatteryRunTimeRemaining OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The UPS battery run time remaining before battery
                exhaustion, in seconds."
   ::= { upsSmartBattery 4 }


upsSmartBatteryReplaceIndicator OBJECT-TYPE
        SYNTAX INTEGER {
                        noBatteryNeedsReplacing(1),
                        batteryNeedsReplacing(2) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Indicates whether the UPS batteries need replacing."
   ::= { upsSmartBattery 5 }


upsSmartBatteryFullChargeVoltage OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The fully charged battery voltage of the battery system
                used in the UPS, expressed in tenths of a volt."
   ::= { upsSmartBattery 6 }


upsSmartBatteryCurrent OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The current battery current expressed in percent of
                maximum current."
   ::= { upsSmartBattery 7 }


-- the upsBaseInput group

upsBaseInputPhase OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The current AC input phase."
   ::= { upsBaseInput 1 }


-- the upsSmartInput group

upsSmartInputLineVoltage OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The current utility line voltage in 1/10 VAC."
   ::= { upsSmartInput 1 }


upsSmartInputMaxLineVoltage OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The maximum utility line voltage in 1/10 VAC over the
                previous 1 minute period."
   ::= { upsSmartInput 2 }


upsSmartInputMinLineVoltage OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The minimum utility line voltage in 1/10 VAC over the
                previous 1 minute period."
   ::= { upsSmartInput 3 }


upsSmartInputFrequency OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The current input frequency to the UPS system in 1/10 Hz."
   ::= { upsSmartInput 4 }


upsSmartInputLineFailCause OBJECT-TYPE
        SYNTAX INTEGER {
                        noTransfer(1),
                        highLineVoltage(2),
                        brownout(3),
                        blackout(4),
                        smallMomentarySag(5),
                        deepMomentarySag(6),
                        smallMomentarySpike(7),
                        largeMomentarySpike(8) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The reason for the occurrence of the last transfer
                to UPS battery power.  The variable is set to
                noTransfer(1) if there is no transfer yet.   The variable
                is set to highLineVoltage(2) if the transfer to battery is
                caused by an over voltage greater than the high transfer
                voltage. The variable is set to brownout(3) if the duration
                of the outage is greater than five seconds and the line
                voltage is between 40 percent of the rated output voltage and
                the low transfer voltage. The variable is set to blackout(4)
                if the duration of the outage is greater than five seconds and
                the line voltage is between 40 percent of the rated output voltage
                and ground.  The variable is set to smallMomentarySag(5)
                if the duration of the outage is less than five seconds and
                the line voltage is between 40 percent of the rated output voltage
                and the low transfer voltage.  The variable is set to
                deepMomentarySag(6) if the duration of the outage is less
                than five seconds and the line voltage is between 40 percent of the
                rated output voltage and ground."
   ::= { upsSmartInput 5 }


-- the upsBaseOutput group

upsBaseOutputStatus OBJECT-TYPE
        SYNTAX INTEGER {
                        unknown(1),
                        onLine(2),
                        onBattery(3),
                        onBoost(4),
                        sleeping(5),
                        onBypass(6),
                        rebooting(7),
                        standBy(8),
                        onBuck(9) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The current state of the UPS.  If the UPS is unable
                to determine the state of the UPS this variable is set
                to unknown(1)."
   ::= { upsBaseOutput 1 }


upsBaseOutputPhase OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The current output phase."
   ::= { upsBaseOutput 2 }


-- the upsSmartOutput group

upsSmartOutputVoltage OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The output voltage of the UPS system in 1/10 VAC."
   ::= { upsSmartOutput 1 }


upsSmartOutputFrequency OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The current output frequency of the UPS system in 1/10 Hz."
   ::= { upsSmartOutput 2 }


upsSmartOutputLoad OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The current UPS load expressed in percent
                of rated capacity."
   ::= { upsSmartOutput 3 }


-- the upsBaseConfig group

upsBaseConfigNumDevices OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The number of devices that are plugged into the UPS."
   ::= { upsBaseConfig 1 }


upsBaseConfigDeviceTable OBJECT-TYPE
        SYNTAX SEQUENCE OF UpsBaseConfigDeviceEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list of devices that are plugged into the UPS.  The
                number of entries is given by the value of
                upsBaseConfigNumDevices."
   ::= { upsBaseConfig 2 }


upsBaseConfigDeviceEntry OBJECT-TYPE
        SYNTAX UpsBaseConfigDeviceEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The devices plugged in to the UPS."
        INDEX {
                indexOfDevice }
   ::= { upsBaseConfigDeviceTable 1 }


UpsBaseConfigDeviceEntry ::= SEQUENCE {
        indexOfDevice    INTEGER,
        nameOfDevice     DisplayString,
        vaRatingOfDevice INTEGER,
        deviceAccept     INTEGER }


indexOfDevice OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index of the device that is plugged into the UPS."
   ::= { upsBaseConfigDeviceEntry 1 }


nameOfDevice OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The name/description of the device plugged into the UPS."
   ::= { upsBaseConfigDeviceEntry 2 }


vaRatingOfDevice OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The volt-amp rating of the device plugged into the UPS."
   ::= { upsBaseConfigDeviceEntry 3 }


deviceAccept OBJECT-TYPE
        SYNTAX INTEGER {
                        yes(1),
                        no(2) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "An entry is added if yes, the entry is deleted if no."
   ::= { upsBaseConfigDeviceEntry 4 }


-- the upsSmartConfig group

upsSmartConfigRatedOutputVoltage OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The nominal output voltage from the UPS in 1/10 VAC.
                Possible values are 1000, 1200, 2080, 2200, 2250, 2300
                and 2400.
                                
                NOTE: Only units that are 2200, 2250, 2300 and 2400 can
                be changed.  Allowable values are 2200, 2250, 2300 and
                2400.
                                
                For these adjustable units, if a value other than
                a supported value is provided in a set request, the
                UPS interprets it as the next lower acceptable value.
                If the provided value is lower than the lowest acceptable
                value, the lowest acceptable value is used."
   ::= { upsSmartConfig 1 }


upsSmartConfigHighTransferVolt OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The maximum line voltage in 1/10 VAC allowed before the
                UPS system transfers to battery backup.
                                
                Allowed value depend on the UPS used:
                120 Volt units allow settings of 1290, 1320, 1350, 1380.
                100 Volt units allow settings of 1080, 1100, 1120, 1140.
                230 Volt units allow settings of 2530, 2640, 2710, 2800.
                208 Volt units allow settings of 2240, 2290, 2340, 2390.
                                
                If a value other than a supported value is provided in a
                set request, the UPS interprets it as the next lower
                acceptable value.  If the provided value is lower than
                the lowest acceptable value, the lowest acceptable
                value is used."
   ::= { upsSmartConfig 2 }


upsSmartConfigLowTransferVolt OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The minimum line voltage in 1/10 VAC allowed before the
                UPS system transfers to battery backup.
                                
                Allowable values depend on the UPS used:
                120 Volt units allow settings of  970, 1000, 1030, 1060.
                100 Volt units allow settings of 810, 830, 850, 870.
                230 Volt units allow settings of 1880, 1960, 2040, 2080.
                208 Volt units allow settings of 1680, 1720, 1770, 1820.
                                
                If a value other than a supported value is provided in a
                set request, the UPS interprets it as a the next higher
                acceptable value.  If the provided value is higher than
                the highest acceptable value, the highest acceptable
                value is used."
   ::= { upsSmartConfig 3 }


upsSmartConfigAlarm OBJECT-TYPE
        SYNTAX INTEGER {
                        timed(1),
                        atLowBattery(2),
                        never(3) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "A flag indicating how the UPS should handle audible line fail
                alarms."
   ::= { upsSmartConfig 4 }


upsSmartConfigAlarmTimer OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The time in seconds after initial line failure at which the
                UPS begins emitting audible alarms (beeping).  This timer is
                observerd only if the value of extControlAlarm is timed(2).
                Allowed values are 0 or 30 seconds.
                                
                If a value other than a supported value is provided in a
                set request, the UPS interprets it as a the next lower
                acceptable value.  If the provided value is lower than
                the lowest acceptable value, the lowest acceptable
                value is used."
   ::= { upsSmartConfig 5 }


upsSmartConfigMinReturnCapacity OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The minimum battery capacity as a percent of full capacity
                required before the UPS will return from a low battery
                shutdown condition.  In other words, the UPS will not
                re-energize the output until the battery capacity is equal
                to this value. Allowed values are 0, 10, 25, or 90  percent.
                                
                If a value other than a supported value is provided in a
                set request, the UPS interprets it as a the next higher
                acceptable value.  If the provided value is higher than
                the highest acceptable value, the highest acceptable
                value is used."
   ::= { upsSmartConfig 6 }


upsSmartConfigSensitivity OBJECT-TYPE
        SYNTAX INTEGER {
                        auto(1),
                        low(2),
                        medium(3),
                        high(4) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The sensitivity of the UPS to utility line abnormalities
                or noises."
   ::= { upsSmartConfig 7 }


upsSmartConfigLowBatteryRunTime OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The desired run time in seconds once the low battery
                condition is reached.  Allowed values are 120, 300, 420,
                or 600 seconds.  During this time the UPS will produce a
                constant warning tone which can not be disabled.
                                
                If a value other than a supported value is provided in a
                set request, the UPS interprets it as a the next higher
                acceptable value.  If the provided value is higher than
                the highest acceptable value, the highest acceptable
                value is used."
   ::= { upsSmartConfig 8 }


upsSmartConfigReturnDelay OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The delay in seconds after utility line power returns
                before the UPS will turn on.  This value is also used
                when the UPS comes out of a reboot and before the UPS
                wakes up from 'sleep' mode.  Allowed values are 0, 60,
                180 and 300 seconds.
                                
                If a value other than a supported value is provided in a
                set request, the UPS interprets it as a the next higher
                acceptable value.  If the provided value is higher than
                the highest acceptable value, the highest acceptable
                value is used."
   ::= { upsSmartConfig 9 }


upsSmartConfigShutoffDelay OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The delay in seconds the UPS remains on after being told
                to turn off.  Allowed values are 12, 18, 24, 30, 36, 42,
                48, 54, 60, 120, 180, 240, 300, 360, 420, 480, 540, and
                600 seconds.
                                
                If a value other than a supported value is provided in a
                set request, the UPS interprets it as next higher acceptable
                value.  If the provided value is higher than the highest
                acceptable value, the highest acceptable value is used."
   ::= { upsSmartConfig 10 }


upsSmartConfigUpsSleepTime OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The time in minutes for the UPS to go to 'sleep' when
                instructed.  When in sleep mode, the UPS will not provide
                output power regardless of the input line state.  Once the
                specified time has elapsed, output power will be restored.
                                
                This is a configuration setting.  The UPS will not go to
                sleep until told to do so by the manager from a management
                station.
                                
                Any input value is allowed, however the UPS only recognizes
                0 - 9999 minutes in one minute increments.
                                
                If the provided value is higher than the highest acceptable
                value, the highest acceptable value is used."
   ::= { upsSmartConfig 11 }


upsSmartConfigSetEEPROMDefaults OBJECT-TYPE
        SYNTAX INTEGER {
                        noSetEEPROMDefaults(1),
                        setEEPROMDefaults(2) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "WRITE: Resets the UPS EEPROM variables to default values.
                READ: returns 0"
   ::= { upsSmartConfig 12 }


-- the upsBaseControl group

upsBaseControlConserveBattery OBJECT-TYPE
        SYNTAX INTEGER {
                        noTurnOffUps(1),
                        turnUpsOffToConserveBattery(2),
                        turnUpsOffToConserveBatteryDelay(3) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Setting this variable to turnUpsOffToConserveBattery(2)
                causes a UPS on battery to be put into 'sleep' mode immediately.
                The (10) means suspending time(10 minutes) before turn off UPS.
                UPS will turn back on when utility power is restored.
                Attempting to turn off a UPS that is not on battery will
                result in a badValue error.
                                
                Setting this value to noTurnOffUps(1) has no
                effect.
                                
                The value noTurnOffUps(1) will always be returned
                when the variable is read."
   ::= { upsBaseControl 1 }


-- the upsSmartControl group

upsSmartControlUpsOff OBJECT-TYPE
        SYNTAX INTEGER {
                        noTurnUpsOff(1),
                        turnUpsOff(2) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Setting this variable to turnUpsOff(2) causes
                the UPS to shut off.  When in this state, the UPS
                will not provide output power regardless of the input
                line state.  The on/off switch on the UPS
                must be toggled for the UPS to return to operation.
                                
                Setting this value to noTurnUpsOff(1) has no
                effect.
                                
                The value noTurnUpsOff(1) will always be returned
                when the variable is read."
   ::= { upsSmartControl 1 }


upsSmartControlRebootUps OBJECT-TYPE
        SYNTAX INTEGER {
                        noRebootUps(1),
                        rebootUps(2) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Setting this variable to rebootUps(2) causes the
                UPS to shut off and turn back on.
                                
                Setting this value to noRebootUps(1) has no effect.
                                
                The value noRebootUps(1) will always be returned
                when the variable is read."
   ::= { upsSmartControl 2 }


upsSmartControlUpsSleep OBJECT-TYPE
        SYNTAX INTEGER {
                        noPutUpsToSleep(1),
                        putUpsToSleep(2) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Setting this variable to putUpsToSleep(2) causes
                the UPS to go to sleep for the time specified by
                upsSmartConfigUpsSleepTime.
                                
                When in sleep mode, the UPS will not provide output
                power regardless of the input line state.  Once the
                specified time has elapsed, output power will be
                restored.
                                
                Setting this value to noPutUpsToSleep(1) has no
                effect.
                                
                The value noPutUpsToSleep(1) will always be returned
                when the variable is read."
   ::= { upsSmartControl 3 }


upsSmartControlSimulatePowerFail OBJECT-TYPE
        SYNTAX INTEGER {
                        noSimulatePowerFailure(1),
                        simulatePowerFailure(2) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Setting this variable to simulatePowerFailure(2) causes
                the UPS switch to battery power.
                                
                Setting this value to noSimulatePowerFailure(1) has no
                effect.
                                
                The value noSimulatePowerFailure(1) will always be returned
                when the variable is read."
   ::= { upsSmartControl 4 }


upsSmartControlFlashAndBeep OBJECT-TYPE
        SYNTAX INTEGER {
                        noFlashAndBeep(1),
                        flashAndBeep(2) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "UPS to identify itself by lighting all indicators
                and beeping.
                                
                Setting this variable to FlashAndBeep(2) causes
                the UPS lights all panel indicators and beeps.
                                
                Setting this value to noFlashAndBeep(1) has no
                effect.
                                
                The value noFlashAndBeep(1) will always be returned
                when the variable is read."
   ::= { upsSmartControl 5 }


upsSmartControlTurnOnUpsLoad OBJECT-TYPE
        SYNTAX INTEGER {
                        noUpsSmartControlTurnOnUpsLoad(1),
                        upsSmartControlTurnOnUpsLoad(2) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Setting this variable to upsSmartControlTurnOnUpsLoad(2)
                causes the UPS switch back to utility power if utility
                power is present.
                                
                Setting this value to noUpsSmartControlTurnOnUpsLoad(1)
                has no effect.
                                
                The value noUpsSmartControlTurnOnUpsLoad(1) will always
                be returned when the variable is read."
   ::= { upsSmartControl 6 }


-- the upsBaseTest group
-- the upsSmartTest group

upsSmartTestDiagnosticSchedule OBJECT-TYPE
        SYNTAX INTEGER {
                        unknown(1),
                        biweekly(2),
                        weekly(3),
                        never(4) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The UPS system's automatic battery test schedule."
  ::= { upsSmartTest 1 }


upsSmartTestDiagnostics OBJECT-TYPE
        SYNTAX INTEGER {
                        noTestDiagnostics(1),
                        testDiagnostics(2) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Setting this variable to testDiagnostics(2) causes
                the UPS to perform a diagnostic self test.
                                
                Setting this value to noTestDiagnostics(1) has no
                effect.
                                
                The value noTestDiagnostics(1) will always be returned
                when the variable is read."
   ::= { upsSmartTest 2 }


upsSmartTestDiagnosticsResults OBJECT-TYPE
        SYNTAX INTEGER {
                        ok(1),
                        failed(2),
                        invalidTest(3),
                        testInProgress(4) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The results of the last UPS diagnostics test performed."
   ::= { upsSmartTest 3 }


upsSmartTestLastDiagnosticsDate OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The date the last UPS diagnostics test was performed in
                mm/dd/yy format."
   ::= { upsSmartTest 4 }


upsSmartTestIndicators OBJECT-TYPE
        SYNTAX INTEGER {
                        noTestIndicators(1),
                        testIndicators(2) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Setting this variable to testIndicators(2) causes
                the UPS to perform a front panel indicator (lights) test.
                                
                Setting this value to noTestIndicators(1) has no effect.
                                
                The value noTestIndicators(1) will always be returned
                when the variable is read."
   ::= { upsSmartTest 5 }


upsSmartTestRuntimeCalibration OBJECT-TYPE
        SYNTAX INTEGER {
                        noPerformCalibration(1),
                        performCalibration(2),
                        cancelCurrentCalibration(3) }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Setting this variable to performCalibration(2) causes
                the UPS to discharge to calibrate the UPS.
                The test will only start if the battery capacity is 100 percent.
                The test runs until capacity is less than 25 percent.
                                
                Setting this variable to cancelCurrentCalibration(3)
                after setting performCalibration(2) will cancel the
                current discharge.
                                
                Setting this variable to noPerformCalibration(1)
                will have no effect.
                                
                The value noPerformCalibration(1) will always be returned
                when the variable is read.
                                
                The result of the calibration will be saved in
                upsSmartTestCalibrationResult."
   ::= { upsSmartTest 6 }


upsSmartTestCalibrationResults OBJECT-TYPE
        SYNTAX INTEGER {
                        ok(1),
                        invalidTest(2),
                        calibrationInProgress(3) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The results of the last runtime calibration.
                                
                Value ok(1) means a successful runtime calibration.
                                
                Value invalidTest(2) indicates last calibration did
                not take place since the battery capacity was below
                100 percent.
                                
                Value calibrationInProgress(3) means a calibration
                is occurring now."
   ::= { upsSmartTest 7 }


upsSmartTestCalibrationDate OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The date the last UPS runtime calibration was
                performed in mm/dd/yy format."
   ::= { upsSmartTest 8 }


-----------------------
--ups ThreePhase group-
-----------------------
upsThreePhaseBatteryVoltage OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Battery Voltage"
   ::= { upsThreePhaseBatteryGrp 1 }


upsThreePhaseBatteryCapacityPercentage OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Battery Capacity Percentage"
   ::= { upsThreePhaseBatteryGrp 2 }


upsThreePhaseBatteryTimeRemain OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Battery Time Remain (unit is Minute)"
   ::= { upsThreePhaseBatteryGrp 3 }


upsThreePhaseBatteryCurrent OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Battery Electric Current"
   ::= { upsThreePhaseBatteryGrp 4 }


upsThreePhaseBatteryTemperature OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Battery Temperature"
   ::= { upsThreePhaseBatteryGrp 5 }


upsThreePhaseInputFrequency OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Input Frequency"
   ::= { upsThreePhaseInputGrp 1 }


upsThreePhaseInputVoltageR OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Input VoltageR"
   ::= { upsThreePhaseInputGrp 2 }


upsThreePhaseInputVoltageS OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Input VoltageS"
   ::= { upsThreePhaseInputGrp 3 }


upsThreePhaseInputVoltageT OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Input VoltageT"
   ::= { upsThreePhaseInputGrp 4 }


upsThreePhaseOutputFrequency OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Output Frequency"
   ::= { upsThreePhaseOutputGrp 1 }


upsThreePhaseOutputVoltageR OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Output VoltageR"
   ::= { upsThreePhaseOutputGrp 2 }


upsThreePhaseOutputVoltageS OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Output VoltageS"
   ::= { upsThreePhaseOutputGrp 3 }


upsThreePhaseOutputVoltageT OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Output VoltageT"
   ::= { upsThreePhaseOutputGrp 4 }


upsThreePhaseOutputLoadPercentageR OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Load PercentageR"
   ::= { upsThreePhaseOutputGrp 5 }


upsThreePhaseOutputLoadPercentageS OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Load PercentageS"
   ::= { upsThreePhaseOutputGrp 6 }


upsThreePhaseOutputLoadPercentageT OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Load PercentageT"
   ::= { upsThreePhaseOutputGrp 7 }


upsThreePhaseBypassSourceFrequency OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Bypass Frequency"
   ::= { upsThreePhaseBypassGrp 1 }


upsThreePhaseBypssSourceVoltageR OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Bypass VoltageR"
   ::= { upsThreePhaseBypassGrp 2 }


upsThreePhaseBypssSourceVoltageS OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Bypass VoltageS"
   ::= { upsThreePhaseBypassGrp 3 }


upsThreePhaseBypssSourceVoltageT OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Bypass VoltageT"
   ::= { upsThreePhaseBypassGrp 4 }


upsThreePhaseDCandRectifierStatusRecRotError OBJECT-TYPE
        SYNTAX INTEGER {
                        yes(14),
                        no(16) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Rectifier Rotation Error"
   ::= { upsThreePhaseDCandRectifierStatusGrp 1 }


upsThreePhaseDCandRectifierStatusLowBatteryShutdown OBJECT-TYPE
        SYNTAX INTEGER {
                        yes(14),
                        no(16) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Low Battery Shutdown"
   ::= { upsThreePhaseDCandRectifierStatusGrp 2 }


upsThreePhaseDCandRectifierStatusLowBattery OBJECT-TYPE
        SYNTAX INTEGER {
                        yes(14),
                        no(16) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Low Battery"
   ::= { upsThreePhaseDCandRectifierStatusGrp 3 }


upsThreePhaseDCandRectifierStatusInAndOut OBJECT-TYPE
        SYNTAX INTEGER {
                        threeInOneOut(2),
                        threeInThreeOut(3) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "In And Put"
   ::= { upsThreePhaseDCandRectifierStatusGrp 4 }


upsThreePhaseDCandRectifierStatusBatteryStatus OBJECT-TYPE
        SYNTAX INTEGER {
                        backup(4),
                        acnormal(5) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Back Status"
   ::= { upsThreePhaseDCandRectifierStatusGrp 5 }


upsThreePhaseDCandRectifierStatusChargeStatus OBJECT-TYPE
        SYNTAX INTEGER {
                        boost(6),
                        float(7),
                        no(16) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Charge Status"
   ::= { upsThreePhaseDCandRectifierStatusGrp 6 }


upsThreePhaseDCandRectifierStatusRecOperating OBJECT-TYPE
        SYNTAX INTEGER {
                        yes(14),
                        no(16) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Rectifier Operating"
   ::= { upsThreePhaseDCandRectifierStatusGrp 7 }


upsThreePhaseUPSStatusBypassFreqFail OBJECT-TYPE
        SYNTAX INTEGER {
                        yes(14),
                        no(16) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Bypass Status"
   ::= { upsThreePhaseUPSStatusGrp 1 }


upsThreePhaseUPSStatusManualBypassBreaker OBJECT-TYPE
        SYNTAX INTEGER {
                        close(8),
                        open(9) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Breaker Status"
   ::= { upsThreePhaseUPSStatusGrp 2 }


upsThreePhaseUPSStatusACStatus OBJECT-TYPE
        SYNTAX INTEGER {
                        normal(10),
                        abnormal(11) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "AC Status"
   ::= { upsThreePhaseUPSStatusGrp 3 }


upsThreePhaseUPSStaticSwitchMode OBJECT-TYPE
        SYNTAX INTEGER {
                        invermode(12),
                        bypassmode(13) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Switch Mode"
   ::= { upsThreePhaseUPSStatusGrp 4 }


upsThreePhaseUPSStatusInverterOperating OBJECT-TYPE
        SYNTAX INTEGER {
                        yes(14),
                        no(16) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Operating"
   ::= { upsThreePhaseUPSStatusGrp 5 }


upsThreePhaseFaultStatusEmergencyStop OBJECT-TYPE
        SYNTAX INTEGER {
                        yes(14),
                        no(16) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Emergency Stop"
   ::= { upsThreePhaseFaultStatusGrp 1 }


upsThreePhaseFaultStatusHighDCShutdown OBJECT-TYPE
        SYNTAX INTEGER {
                        yes(14),
                        no(16) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "High DC Shutdown"
   ::= { upsThreePhaseFaultStatusGrp 2 }


upsThreePhaseFaultStatusBypassBreaker OBJECT-TYPE
        SYNTAX INTEGER {
                        yes(14),
                        no(16) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Bypass Breaker"
   ::= { upsThreePhaseFaultStatusGrp 3 }


upsThreePhaseFaultStatusOverLoad OBJECT-TYPE
        SYNTAX INTEGER {
                        yes(14),
                        no(16) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Over Load"
   ::= { upsThreePhaseFaultStatusGrp 4 }


upsThreePhaseFaultStatusInverterOutputFail OBJECT-TYPE
        SYNTAX INTEGER {
                        yes(14),
                        no(16) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Output Fail"
   ::= { upsThreePhaseFaultStatusGrp 5 }


upsThreePhaseFaultStatusOverTemperature OBJECT-TYPE
        SYNTAX INTEGER {
                        yes(14),
                        no(16) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Over Temperature"
   ::= { upsThreePhaseFaultStatusGrp 6 }


upsThreePhaseFaultStatusShortCircuit OBJECT-TYPE
        SYNTAX INTEGER {
                        yes(14),
                        no(16) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Short Circuit"
   ::= { upsThreePhaseFaultStatusGrp 7 }


upsThreePhaseRatingRectifierVoltage OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Rectifier Voltage"
   ::= { upsThreePhaseRatingGrp 1 }


upsThreePhaseRatingRectifierFrequency OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Rectifier Frequency"
   ::= { upsThreePhaseRatingGrp 2 }


upsThreePhaseRatingBypassVoltage OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Bypass Voltage"
   ::= { upsThreePhaseRatingGrp 3 }


upsThreePhaseRatingBypassFrequency OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Bypass Frequency"
   ::= { upsThreePhaseRatingGrp 4 }


upsThreePhaseRatingOutputVoltage OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Output Voltage"
   ::= { upsThreePhaseRatingGrp 5 }


upsThreePhaseRatingOutputFrequency OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Output Frequency"
   ::= { upsThreePhaseRatingGrp 6 }


upsThreePhaseRatingBatteryVoltage OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Battery Voltage"
   ::= { upsThreePhaseRatingGrp 7 }


upsThreePhaseRatingPower OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Power Rating"
   ::= { upsThreePhaseRatingGrp 8 }


-----------------------
-----------------------

upsEnvStatus OBJECT IDENTIFIER  ::= { upsEnvironment 1 }

upsEnvTemperature OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The ambient environment temperature."
        ::= { upsEnvStatus 1 }


upsEnvHumidity OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The environment humidity."
        ::= { upsEnvStatus 2 }


upsEnvOverTemperature OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Alarm dupsAlarmOverTemperature on when the environment
                temperature over the value."
        ::= { upsEnvSetting 1 }


upsEnvOverHumidity OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Alarm dupsAlarmOverHumidity on when the environment
                humidity over the value."
        ::= { upsEnvSetting 3 }


upsEnvSecurity1 OBJECT-TYPE
        SYNTAX INTEGER {
                        normal(1),
                        abnormal(2) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Security status"
        ::= { upsEnvStatus 5 }


upsEnvSecurity2 OBJECT-TYPE
        SYNTAX INTEGER {
                        normal(1),
                        abnormal(2) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Security status"
        ::= { upsEnvStatus 6 }


upsEnvSecurity3 OBJECT-TYPE
        SYNTAX INTEGER {
                        normal(1),
                        abnormal(2) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Security status"
        ::= { upsEnvStatus 7 }


upsEnvSecurity4 OBJECT-TYPE
        SYNTAX INTEGER {
                        normal(1),
                        abnormal(2) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Security status"
        ::= { upsEnvStatus 8 }


upsEnvSecurity5 OBJECT-TYPE
        SYNTAX INTEGER {
                        normal(1),
                        abnormal(2) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Security status"
        ::= { upsEnvStatus 9 }


upsEnvSecurity6 OBJECT-TYPE
        SYNTAX INTEGER {
                        normal(1),
                        abnormal(2) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Security status"
        ::= { upsEnvStatus 10 }


upsEnvSecurity7 OBJECT-TYPE
        SYNTAX INTEGER {
                        normal(1),
                        abnormal(2) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Security status"
        ::= { upsEnvStatus 11 }


upsEnvWater OBJECT-TYPE
        SYNTAX INTEGER {
                        normal(1),
                        abnormal(2) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Water status"
        ::= { upsEnvStatus 3 }


upsEnvSmoke OBJECT-TYPE
        SYNTAX INTEGER {
                        normal(1),
                        abnormal(2) }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Smoke status"
        ::= { upsEnvStatus 4 }


upsEnvSetting OBJECT IDENTIFIER         ::= { upsEnvironment 2 }

upsEnvUnderTemperature OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Alarm dupsAlarmUnderTemperature on when the environment
                temperature below the value."
        ::= { upsEnvSetting 2 }


upsEnvUnderHumidity OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Alarm dupsAlarmUnderHumidity on when the environment
                humidity below the value."
        ::= { upsEnvSetting 4 }



communicationLost TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "SEVERE: Communication to the UPS has been lost.  Steps
                to reestablish communication are in progress."
        --#TYPE "PPC UPS: Communication failure"
        --#SUMMARY "Communication to the UPS has been lost."
        --#ARGUMENTS { }
        --#SEVERITY CRITICAL
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE DEGRADED
 ::= 1



upsOverLoad TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "SEVERE: The UPS has sensed a load greater than 100 percent
                of its rated capacity."
        --#TYPE "PPC UPS: UPS overload"
        --#SUMMARY "The UPS has sensed a load greater than 100 percent of its rated capacity."
        --#ARGUMENTS { }
        --#SEVERITY CRITICAL
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE DEGRADED
 ::= 2



upsDiagnosticsFailed TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "SEVERE: The UPS failed its internal diagnostic self-test."
        --#TYPE "PPC UPS: Failed self-test"
        --#SUMMARY "The UPS has failed its internal diagnostic self-test."
        --#ARGUMENTS { }
        --#SEVERITY CRITICAL
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE DEGRADED
 ::= 3



upsDischarged TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "SEVERE: The UPS just started a runtime calibration
                discharge.  The UPS batteries are being discharged."
        --#TYPE "PPC UPS: Deep discharge"
        --#SUMMARY "The UPS has just started a runtime calibration discharge."
        --#ARGUMENTS { }
        --#SEVERITY CRITICAL
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE DEGRADED
 ::= 4



upsOnBattery TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: The UPS has switched to battery backup power."
        --#TYPE "PPC UPS: On battery"
        --#SUMMARY "The UPS has switched to battery backup power."
        --#ARGUMENTS { }
        --#SEVERITY MAJOR
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE OPERATIONAL
 ::= 5



boostOn TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: The UPS has enabled Boost."
        --#TYPE "PPC UPS: SmartBoost"
        --#SUMMARY "The UPS has enabled Boost."
        --#ARGUMENTS { }
        --#SEVERITY MINOR
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE OPERATIONAL
 ::= 6



lowBattery TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "SEVERE: The UPS batteries are low and will soon be exhausted.
                If utility power is not restored the UPS will put itself
                to 'sleep' and immediately cut power to the load."
        --#TYPE "PPC UPS: Low battery"
        --#SUMMARY "The UPS batteries are low and will soon be exhausted."
        --#ARGUMENTS { }
        --#SEVERITY CRITICAL
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE DEGRADED
 ::= 7



communicationEstablished TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "INFORMATION: Communication with the UPS has been
                established."
        --#TYPE "PPC UPS: Communication established"
        --#SUMMARY "Communication with the UPS has been established."
        --#ARGUMENTS { }
        --#SEVERITY INFORMATIONAL
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE OPERATIONAL
 ::= 8



powerRestored TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "INFORMATION: Utility power has been restored."
        --#TYPE "PPC UPS: Utility restored"
        --#SUMMARY "Normal power has been restored to the UPS."
        --#ARGUMENTS { }
        --#SEVERITY INFORMATIONAL
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE OPERATIONAL
 ::= 9



upsDiagnosticsPassed TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "INFORMATION: The UPS passed its internal self-test."
        --#TYPE "PPC UPS: Passed self-test"
        --#SUMMARY "The UPS has passed its internal self-test."
        --#ARGUMENTS { }
        --#SEVERITY INFORMATIONAL
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE OPERATIONAL
 ::= 10



returnFromLowBattery TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "INFORMATION: The UPS has returned from a low battery
                condition."
        --#TYPE "PPC UPS: Battery normal"
        --#SUMMARY "The UPS has returned from a low battery condition."
        --#ARGUMENTS { }
        --#SEVERITY INFORMATIONAL
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE OPERATIONAL
 ::= 11



upsTurnedOff TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: The UPS has been turned 'off' by the
                management station."
        --#TYPE "PPC UPS: Switching off"
        --#SUMMARY "The UPS is being switched off by a management station."
        --#ARGUMENTS { }
        --#SEVERITY MAJOR
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE NONOPERATIONAL
 ::= 12



upsSleeping TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: The UPS is entering 'sleep' mode.  Power
                to the load will be cut off."
        --#TYPE "PPC UPS: Going to sleep"
        --#SUMMARY "The UPS is going into sleep mode."
        --#ARGUMENTS { }
        --#SEVERITY MAJOR
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE NONOPERATIONAL
 ::= 13



upsWokeUp TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "INFORMATION: The UPS woke up from 'sleep' mode.  Power
                to the load has been restored."
        --#TYPE "PPC UPS: Wake up"
        --#SUMMARY "The UPS has woke up from sleep mode."
        --#ARGUMENTS { }
        --#SEVERITY INFORMATIONAL
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE OPERATIONAL
 ::= 14



upsRebootStarted TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: The UPS has started its reboot sequence.  After
                the specified delay the UPS will perform a reboot."
        --#TYPE "PPC UPS: Starting reboot"
        --#SUMMARY "The UPS has started its reboot sequence."
        --#ARGUMENTS { }
        --#SEVERITY MAJOR
        --#TIMEINDEX 1
        --#HELP ""
        --#HELPTAG 0
        --#STATE NONOPERATIONAL
 ::= 15


envOverTemperature TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: The environment temperature exceed the normal value."
 ::= 16


envTemperatureNormal TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "INFORMATION: The environment temperature is normal."
 ::= 17


envOverHumidity TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: The environment humidity exceed the normal value."
 ::= 18


envHumidityNormal TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "INFORMATION: The environment humidity is normal."
 ::= 19


envSmokeAbnormal TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: Smoke is abnormal."
 ::= 20


envWaterAbnormal TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: Water is abnormal."
 ::= 21


envSecurityAbnormal TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: Security is abnormal."
 ::= 22


--envSmokeNormal TRAP-TYPE
--      ENTERPRISE ppc
--      DESCRIPTION 
--              "INFORMATION: Smoke is normal."
-- ::= 23


envWaterNormal TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "INFORMATION: Water is normal."
 ::= 24


--envSecurityNormal TRAP-TYPE
--      ENTERPRISE ppc
--      DESCRIPTION 
--              "INFORMATION: Security is normal."
-- ::= 25


envGasAbnormal TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: Gas Alarm"
 ::= 26


upsTemp TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: UPS Temperature Overrun"
 ::= 27


upsLoadNormal TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: UPS Load Normal"
 ::= 28


upsTempNormal TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: UPS temperature Normal"
 ::= 29


envUnderTemperature TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: The environment temperature below the normal value."
 ::= 30


envUnderHumidity TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: The environment humidity below the normal value."
 ::= 31


upsBypass TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: The UPS is entering 'bypass' mode."
 ::= 32


envSecurity1 TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: Security1 Alarm."
 ::= 33


envSecurity2 TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: Security2 Alarm."
 ::= 34


envSecurity3 TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: Security3 Alarm."
 ::= 35


envSecurity4 TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: Security4 Alarm."
 ::= 36


envSecurity5 TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: Security5 Alarm."
 ::= 37


envSecurity6 TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: Security6 Alarm."
 ::= 38


envSecurity7 TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: Security7 Alarm."
 ::= 39


--envSecurity1Return TRAP-TYPE
--      ENTERPRISE ppc
--      DESCRIPTION 
--              "WARNING: Security1 Normal."
-- ::= 40


--envSecurity2Return TRAP-TYPE
--      ENTERPRISE ppc
--      DESCRIPTION 
--              "WARNING: Security2 Normal"
-- ::= 41


--envSecurity3Return TRAP-TYPE
--      ENTERPRISE ppc
--      DESCRIPTION 
--              "WARNING: Security3 Normal."
-- ::= 42


--envSecurity4Return TRAP-TYPE
--      ENTERPRISE ppc
--      DESCRIPTION 
--              "WARNING: Security4 Normal."
-- ::= 43


--envSecurity5Return TRAP-TYPE
--      ENTERPRISE ppc
--      DESCRIPTION 
--              "WARNING: Security5 Normal."
-- ::= 44


--envSecurity6Return TRAP-TYPE
--      ENTERPRISE ppc
--      DESCRIPTION 
--              "WARNING: Security6 Normal."
-- ::= 45


--envSecurity7Return TRAP-TYPE
--      ENTERPRISE ppc
--      DESCRIPTION 
--              "WARNING: Security7 Normal."
-- ::= 46


upsRecroterror TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: Rectifier Rotation Error"
 ::= 47


upsBypassFreFail TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: Bypass Frequency Fail"
 ::= 48


upsBypassacnormal TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: Bypass AC Normal"
 ::= 49


upsBypassacabnormal TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: Bypass AC Abnormal"
 ::= 50


upsTest TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: UPS Test"
 ::= 51


upsScheduleShutdown TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "WARNING: UPS Schedule Shutdown"
 ::= 52

upsBypassReturn TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "The UPS return from Bypass Mode"
 ::= 53

upsShortCircuitShutdown TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "The UPS Short Circuit Shutdown"
 ::= 54
 
upsInverterOutputFailShutdown TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "The UPS Inverter Output Fail Shutdown"
 ::= 55
 
upsBypassBreadkerOnShutdown TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "The UPS Manual Bypass Breaker on Shutdown"
 ::= 56
 
upsHighDCShutdown TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "The UPS High DC Shutdown"
 ::= 57
 
upsEmergencyStop TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "The UPS Emergency Stop"
 ::= 58
 
upsInverterMode TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "The UPS Static Switch in Inverter Mode"
 ::= 59
 
upsBypassMode TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "The UPS Static Switch in Bypass Mode"
 ::= 60
 
upsOverTemperatureShutdown TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "The UPS Over Temperature Shutdown"
 ::= 61
 
upsOverLoadShutdown TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "The UPS Overload Shutdown"
 ::= 62
 
upsCapacityUnderrun TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "The UPS Capacity Underrun"
 ::= 63
 
upsCapacityNormal TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "The UPS Capacity Normal"
 ::= 64
 
upsLowBatteryShutdown TRAP-TYPE
        ENTERPRISE ppc
        DESCRIPTION 
                "The UPS Low Battery Shutdown"
 ::= 67
 
END