summaryrefslogtreecommitdiff
path: root/MIBS/allied/AT-ENVMON-MIB
blob: c2d6f38b4bfbbc9c878c04e312f12ec9accb1f79 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
-- ============================================================================
-- AT-ENVMON.MIB, Allied Telesis enterprise MIB: Environment Monitoring
--
-- Copied from ATR-ENVMON.MIB of pre 2.9.1 release
--
-- Copyright (c) 2006 by Allied Telesis, Inc.
-- All rights reserved.
-- 
-- ============================================================================

AT-ENVMON-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    OBJECT-TYPE,
    NOTIFICATION-TYPE,
    Unsigned32,
    enterprises
        FROM SNMPv2-SMI

    TruthValue,
	TEXTUAL-CONVENTION
        FROM SNMPv2-TC

	ifIndex
		FROM IF-MIB

	DisplayStringUnsized
		FROM AT-SMI-MIB

	sysinfo
		FROM AT-SYSINFO-MIB
;

envMon MODULE-IDENTITY
    LAST-UPDATED "200603070000Z"
    ORGANIZATION "Allied Telesis, Inc"
    CONTACT-INFO
        "http://www.alliedtelesis.com"
    DESCRIPTION
        "The AT Environment Monitoring MIB for managing and
        reporting data relating to voltage rails, fan speeds,
        temperature sensors and power supply units."

    REVISION "200603070000Z"
    DESCRIPTION
	"Initial Revision"
  ::= { sysinfo 10 }

-- Textual Conventions

EnvMonPsbSensorType ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "Indicates the type of a Power Supply Bay Device sensor."
    SYNTAX       INTEGER { 
			psbSensorTypeInvalid	(0), 
			fanSpeedDiscrete		(1), 
			temperatureDiscrete		(2), 
			voltageDiscrete			(3) }

--  This section of the MIB contains new generic environment monitoring
--  data. It relates to temperature, fanspeed, voltage and power supply
--  bay device monitors.

-- ---------------------------------------------------------- --
-- The Environment Monitoring Fan Table
-- ---------------------------------------------------------- --

    envMonFanTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF EnvMonFanEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "A table of fans installed in the device that have their
             fan speeds monitored by environment monitoring hardware."
    ::= { envMon 1 }

    envMonFanEntry OBJECT-TYPE
        SYNTAX      EnvMonFanEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The description, current speed, lower threshold speed and
             current status of a fan."
        INDEX { envMonFanBoardIndex, envMonFanIndex }
    ::= { envMonFanTable 1 }

    EnvMonFanEntry ::=
        SEQUENCE {
            envMonFanBoardIndex
                Unsigned32,
            envMonFanIndex
                Unsigned32,
            envMonFanDescription
                DisplayStringUnsized,
            envMonFanCurrentSpeed
                Unsigned32,
            envMonFanLowerThreshold
                Unsigned32,
            envMonFanAlarm
                TruthValue
            }

    envMonFanBoardIndex OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The index of the board hosting this fan in the board table."
    ::= { envMonFanEntry 1 }

    envMonFanIndex OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The numeric identifier of this fan within the context of its host board."
    ::= { envMonFanEntry 2 }

    envMonFanDescription OBJECT-TYPE
        SYNTAX      DisplayStringUnsized (SIZE (0..30))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The text description of this fan."
    ::= { envMonFanEntry 3 }

    envMonFanCurrentSpeed OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The current speed of this fan in revolutions per
             minute."
    ::= { envMonFanEntry 4 }

    envMonFanLowerThreshold OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The minimum acceptable speed of the fan (in revolutions
             per minute)."
    ::= { envMonFanEntry 5 }

    envMonFanAlarm OBJECT-TYPE
        SYNTAX TruthValue
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "An indication of whether this fan is currently in an
             alarm condition. A value of TRUE indicates that its
             current speed is too low, FALSE indicates that the
             current speed is acceptable."
    ::= { envMonFanEntry 6 }

-- ---------------------------------------------------------- --
-- The Environment Monitoring Voltage Table
-- ---------------------------------------------------------- --

    envMonVoltageTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF EnvMonVoltageEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "A table of voltage rails in the device that are
             monitored by environment monitoring hardware."
    ::= { envMon 2 }

    envMonVoltageEntry OBJECT-TYPE
        SYNTAX      EnvMonVoltageEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The description, current value, upper & lower threshold
             settings and current status of a voltage rail."
        INDEX { envMonVoltageBoardIndex, envMonVoltageIndex }
    ::= { envMonVoltageTable 1 }

    EnvMonVoltageEntry ::=
        SEQUENCE {
            envMonVoltageBoardIndex
                Unsigned32,
            envMonVoltageIndex
                Unsigned32,
            envMonVoltageDescription
                DisplayStringUnsized,
            envMonVoltageCurrent
                INTEGER,
            envMonVoltageUpperThreshold
                INTEGER,
            envMonVoltageLowerThreshold
                INTEGER,
            envMonVoltageAlarm
                TruthValue
            }

    envMonVoltageBoardIndex OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The index of the board hosting this voltage sensor in the board table."
    ::= { envMonVoltageEntry 1 }

    envMonVoltageIndex OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The numeric identifier of this voltage rail within the context of its host board."
    ::= { envMonVoltageEntry 2 }

    envMonVoltageDescription OBJECT-TYPE
        SYNTAX      DisplayStringUnsized (SIZE (0..30))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The text description of this voltage rail."
    ::= { envMonVoltageEntry 3 }

    envMonVoltageCurrent OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The current reading of this voltage rail in millivolts."
    ::= { envMonVoltageEntry 4 }

    envMonVoltageUpperThreshold OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The maximum acceptable reading of this voltage rail in millivolts."
    ::= { envMonVoltageEntry 5 }

    envMonVoltageLowerThreshold OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The minimum acceptable reading of this voltage rail in millivolts."
    ::= { envMonVoltageEntry 6 }

    envMonVoltageAlarm OBJECT-TYPE
        SYNTAX TruthValue
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "An indication of whether this voltage rail is currently
             in an alarm condition. A value of TRUE indicates that
             its current reading is outside its threshold range,
             FALSE indicates that the current reading is acceptable."
    ::= { envMonVoltageEntry 7 }


-- ---------------------------------------------------------- --
-- The Environment Monitoring Temperature Table
-- ---------------------------------------------------------- --

    envMonTemperatureTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF EnvMonTemperatureEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "A table of temperature sensors in the device that are
             monitored by environment monitoring hardware."
    ::= { envMon 3 }

    envMonTemperatureEntry OBJECT-TYPE
        SYNTAX      EnvMonTemperatureEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The description, current value, upper threshold setting
             and current status of a temperature sensor."
        INDEX { envMonTemperatureBoardIndex, envMonTemperatureIndex }
    ::= { envMonTemperatureTable 1 }

    EnvMonTemperatureEntry ::=
        SEQUENCE {
            envMonTemperatureBoardIndex
                Unsigned32,
            envMonTemperatureIndex
                Unsigned32,
            envMonTemperatureDescription
                DisplayStringUnsized,
            envMonTemperatureCurrent
                INTEGER,
            envMonTemperatureUpperThreshold
                INTEGER,
            envMonTemperatureAlarm
                TruthValue
            }

    envMonTemperatureBoardIndex OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The index of the board hosting this temperature sensor in the board table."
    ::= { envMonTemperatureEntry 1 }

    envMonTemperatureIndex OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The numeric identifier of this temperature sensor within the context of its host board."
    ::= { envMonTemperatureEntry 2 }

    envMonTemperatureDescription OBJECT-TYPE
        SYNTAX      DisplayStringUnsized (SIZE (0..30))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The text description of this temperature sensor."
    ::= { envMonTemperatureEntry 3 }

    envMonTemperatureCurrent OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The current reading of this temperature sensor in tenths of a degree Celcius."
    ::= { envMonTemperatureEntry 4 }

    envMonTemperatureUpperThreshold OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The maximum acceptable reading of this temperature
             sensor in tenths of a degree Celcius."
    ::= { envMonTemperatureEntry 5 }

    envMonTemperatureAlarm OBJECT-TYPE
        SYNTAX TruthValue
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "An indication of whether this temperature sensor is
             currently in an alarm condition. A value of TRUE indicates
             that its current reading is outside its threshold range,
             FALSE indicates that the current reading is acceptable."
    ::= { envMonTemperatureEntry 6 }


-- ---------------------------------------------------------- --
-- The Environment Monitoring Power Supply Bay Device Table
-- ---------------------------------------------------------- --

    envMonPsbObjects            OBJECT IDENTIFIER ::= { envMon 4 }

    envMonPsbTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF EnvMonPsbEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "A table showing power supply bays in the system and info
             on any devices that are present."
    ::= { envMonPsbObjects 1 }

    envMonPsbEntry OBJECT-TYPE
        SYNTAX      EnvMonPsbEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The description and current status of a power supply
             bay device."
        INDEX { envMonPsbHostBoardIndex, envMonPsbHostSlotIndex }
    ::= { envMonPsbTable 1 }

    EnvMonPsbEntry ::=
        SEQUENCE {
            envMonPsbHostBoardIndex
                Unsigned32,
            envMonPsbHostSlotIndex
                Unsigned32,
            envMonPsbHeldBoardIndex
                Unsigned32,
            envMonPsbHeldBoardId
                OBJECT IDENTIFIER,
            envMonPsbDescription
                DisplayStringUnsized
            }

    envMonPsbHostBoardIndex OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The index of the board hosting this PSB in the board table."
    ::= { envMonPsbEntry 1 }

    envMonPsbHostSlotIndex OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The index of this PSB slot within the context of its host board.
                 This index is fixed for each slot, on each type of board."
    ::= { envMonPsbEntry 2 }

    envMonPsbHeldBoardIndex OBJECT-TYPE
        SYNTAX Unsigned32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The index of a board installed in this power supply bay.
            This value corresponds to envMonPsbSensorBoardIndex for
            each sensor on this board. A value of 0 indicates that a
            board is is either not present or not supported."
    ::= { envMonPsbEntry 3 }

    envMonPsbHeldBoardId OBJECT-TYPE
        SYNTAX OBJECT IDENTIFIER
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "The type of board installed in this power supply bay. The
            values of this object are taken from the pprXxx object IDs
            under the boards sub-tree in the parent MIB. A value of 0
            indicates that a board is is either not present or not
            supported."
    ::= { envMonPsbEntry 4 }

    envMonPsbDescription OBJECT-TYPE
        SYNTAX      DisplayStringUnsized (SIZE (0..30))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The text description of this power supply bay."
    ::= { envMonPsbEntry 5 }

    envMonPsbSensorTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF EnvMonPsbSensorEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "A table of environment monitoring sensors on installed
             power supply bay devices."
    ::= { envMonPsbObjects 2 }

    envMonPsbSensorEntry OBJECT-TYPE
        SYNTAX      EnvMonPsbSensorEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The description and current status of a power supply
             bay device."
        INDEX { envMonPsbSensorBoardIndex, envMonPsbSensorIndex }
    ::= { envMonPsbSensorTable 1 }

    EnvMonPsbSensorEntry ::=
        SEQUENCE {
            envMonPsbSensorBoardIndex
                Unsigned32,
            envMonPsbSensorIndex
                Unsigned32,
            envMonPsbSensorType
                EnvMonPsbSensorType,
            envMonPsbSensorDescription
                DisplayStringUnsized,
            envMonPsbSensorAlarm
                TruthValue
            }

    envMonPsbSensorBoardIndex OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The index of the board hosting this sensor in the board table."
    ::= { envMonPsbSensorEntry 1 }

    envMonPsbSensorIndex OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The index of this power supply bay environmental sensor, within the
             context of its host board."
    ::= { envMonPsbSensorEntry 2 }

    envMonPsbSensorType OBJECT-TYPE
        SYNTAX EnvMonPsbSensorType
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "Indicates the type of environmental variable this sensor detects."
    ::= { envMonPsbSensorEntry 3 }

    envMonPsbSensorDescription OBJECT-TYPE
        SYNTAX      DisplayStringUnsized (SIZE (0..30))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The text description of this power supply bay environmental sensor."
    ::= { envMonPsbSensorEntry 4 }

    envMonPsbSensorAlarm OBJECT-TYPE
        SYNTAX TruthValue
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
            "An indication of whether this environmental sensor is currently
             in an alarm condition. A value of TRUE indicates that
             the device is in a failure condition, FALSE indicates
             that the device is functioning normally."
    ::= { envMonPsbSensorEntry 5 }
                    
                      
-- ---------------------------------------------------------- --
-- The Environment Monitoring SNMP Trap Objects
-- ---------------------------------------------------------- --

    envMonTraps    OBJECT IDENTIFIER ::= { envMon 5 }

    envMonFanAlarmSetEvent NOTIFICATION-TYPE
        OBJECTS { envMonFanBoardIndex,
                  envMonFanIndex,
                  envMonFanDescription,
                  envMonFanLowerThreshold,
                  envMonFanCurrentSpeed }
        STATUS  current
        DESCRIPTION
                "Triggered when the monitored speed of a fan
                 drops below its lower threshold."
    ::= { envMonTraps 1 }

    envMonFanAlarmClearedEvent NOTIFICATION-TYPE
        OBJECTS { envMonFanBoardIndex,
                  envMonFanIndex,
                  envMonFanDescription,
                  envMonFanLowerThreshold,
                  envMonFanCurrentSpeed }
        STATUS  current
        DESCRIPTION
                "Triggered when the monitored speed of a fan
                 returns to an acceptable value, the fan
                 having previously been in an alarm condition."
    ::= { envMonTraps 2 }

    envMonVoltAlarmSetEvent NOTIFICATION-TYPE
        OBJECTS { envMonVoltageBoardIndex,
                  envMonVoltageIndex,
                  envMonVoltageDescription,
                  envMonVoltageUpperThreshold,
                  envMonVoltageLowerThreshold,
                  envMonVoltageCurrent }
        STATUS  current
        DESCRIPTION
                "Triggered when the voltage of a monitored
                 voltage rail, goes out of tolerance by
                 either dropping below its lower threshold,
                 or exceeding its upper threshold."
    ::= { envMonTraps 3 }

    envMonVoltAlarmClearedEvent NOTIFICATION-TYPE
        OBJECTS { envMonVoltageBoardIndex,
                  envMonVoltageIndex,
                  envMonVoltageDescription,
                  envMonVoltageUpperThreshold,
                  envMonVoltageLowerThreshold,
                  envMonVoltageCurrent }
        STATUS  current
        DESCRIPTION
                "Triggered when the voltage of a monitored
                 voltage rail returns to an acceptable value,
                 having previously been in an alarm condition."
    ::= { envMonTraps 4 }

    envMonTempAlarmSetEvent NOTIFICATION-TYPE
        OBJECTS { envMonTemperatureBoardIndex,
                  envMonTemperatureIndex,
                  envMonTemperatureDescription,
                  envMonTemperatureUpperThreshold,
                  envMonTemperatureCurrent }
        STATUS  current
        DESCRIPTION
                "Triggered when a monitored temperature
                 exceeds its upper threshold."
    ::= { envMonTraps 5 }

    envMonTempAlarmClearedEvent NOTIFICATION-TYPE
        OBJECTS { envMonTemperatureBoardIndex,
                  envMonTemperatureIndex,
                  envMonTemperatureDescription,
                  envMonTemperatureUpperThreshold,
                  envMonTemperatureCurrent }
        STATUS  current
        DESCRIPTION
                "Triggered when a monitored temperature
                 returns to an acceptable value, having
                 previously been in an alarm condition."
    ::= { envMonTraps 6 }

    envMonPsbAlarmSetEvent NOTIFICATION-TYPE
        OBJECTS { envMonPsbSensorBoardIndex,
                  envMonPsbSensorIndex,
                  envMonPsbSensorType,
                  envMonPsbSensorDescription }
        STATUS  current
        DESCRIPTION
                "Triggered when a monitored parameter of
                 a power supply bay device goes out of
                 tolerance."
    ::= { envMonTraps 7 }

    envMonPsbAlarmClearedEvent NOTIFICATION-TYPE
        OBJECTS { envMonPsbSensorBoardIndex,
                  envMonPsbSensorIndex,
                  envMonPsbSensorType,
                  envMonPsbSensorDescription }
        STATUS  current
        DESCRIPTION
                "Triggered when a monitored parameter of
                 a power supply bay device returns to an
                 acceptable value, having previously been
                 in an alarm condition."
    ::= { envMonTraps 8 }
                                            