summaryrefslogtreecommitdiff
path: root/MIBS/alvarion/ALVARION-DOT11-WLAN-MIB
blob: ca595efacb7404309b06e728d73c4e0928202336 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132
4133
4134
4135
4136
4137
4138
4139
4140
4141
4142
4143
4144
4145
4146
4147
4148
4149
4150
4151
4152
4153
4154
4155
4156
4157
4158
4159
4160
4161
4162
4163
4164
4165
4166
4167
4168
4169
4170
4171
4172
4173
4174
4175
4176
4177
4178
4179
4180
4181
4182
4183
4184
4185
4186
4187
4188
4189
4190
4191
4192
4193
4194
4195
4196
4197
4198
4199
4200
4201
4202
4203
4204
4205
4206
4207
4208
4209
4210
4211
4212
4213
4214
4215
4216
4217
4218
4219
4220
4221
4222
4223
4224
4225
4226
4227
4228
4229
4230
4231
4232
4233
4234
4235
4236
4237
4238
4239
4240
4241
4242
4243
4244
4245
4246
4247
4248
4249
4250
4251
4252
4253
4254
4255
4256
4257
4258
4259
4260
4261
4262
4263
4264
4265
4266
4267
4268
4269
4270
4271
4272
4273
4274
4275
4276
4277
4278
4279
4280
4281
4282
4283
4284
4285
4286
4287
4288
4289
4290
4291
4292
4293
4294
4295
4296
4297
4298
4299
4300
4301
4302
4303
4304
4305
4306
4307
4308
4309
4310
4311
4312
4313
4314
4315
4316
4317
4318
4319
4320
4321
4322
4323
4324
4325
4326
4327
4328
4329
4330
4331
4332
4333
4334
4335
4336
4337
4338
4339
4340
4341
4342
4343
4344
4345
4346
4347
4348
4349
4350
4351
4352
4353
4354
4355
4356
4357
4358
4359
4360
4361
4362
4363
4364
4365
4366
4367
4368
4369
4370
4371
4372
4373
4374
4375
4376
4377
4378
4379
4380
4381
4382
4383
4384
4385
4386
4387
4388
4389
4390
4391
4392
4393
4394
4395
4396
4397
4398
4399
4400
4401
4402
4403
4404
4405
4406
4407
4408
4409
4410
4411
4412
4413
4414
4415
4416
4417
4418
4419
4420
4421
4422
4423
4424
4425
4426
4427
4428
4429
4430
4431
4432
4433
4434
4435
4436
4437
4438
4439
4440
4441
4442
4443
4444
4445
4446
4447
4448
4449
4450
4451
4452
4453
4454
4455
4456
4457
4458
4459
4460
4461
4462
4463
4464
4465
4466
4467
4468
4469
4470
4471
4472
4473
4474
4475
4476
4477
4478
4479
4480
4481
4482
4483
4484
4485
4486
4487
4488
4489
4490
4491
4492
4493
4494
4495
4496
4497
4498
4499
4500
4501
4502
4503
4504
4505
4506
4507
4508
4509
4510
4511
4512
4513
4514
4515
4516
4517
4518
4519
4520
4521
4522
4523
4524
4525
4526
4527
4528
4529
4530
4531
4532
4533
4534
4535
4536
4537
4538
4539
4540
4541
4542
4543
4544
4545
4546
4547
4548
4549
4550
4551
4552
4553
4554
4555
4556
4557
4558
4559
4560
4561
4562
4563
4564
4565
4566
4567
4568
4569
4570
4571
4572
4573
4574
4575
4576
4577
4578
4579
4580
4581
4582
4583
4584
4585
4586
4587
4588
4589
4590
4591
4592
4593
4594
4595
4596
4597
4598
4599
4600
4601
4602
4603
4604
4605
4606
4607
4608
4609
4610
4611
4612
4613
4614
4615
4616
4617
4618
4619
4620
4621
4622
4623
4624
4625
4626
4627
4628
4629
4630
4631
4632
4633
4634
4635
4636
4637
4638
4639
4640
4641
4642
4643
4644
4645
4646
4647
4648
4649
4650
4651
4652
4653
4654
4655
4656
4657
4658
4659
4660
4661
4662
4663
4664
4665
4666
4667
4668
4669
4670
4671
4672
4673
4674
4675
4676
4677
4678
4679
4680
4681
4682
4683
4684
4685
4686
4687
4688
4689
4690
4691
4692
4693
4694
4695
4696
4697
4698
4699
4700
4701
4702
4703
4704
4705
4706
4707
4708
4709
4710
4711
4712
4713
4714
4715
4716
4717
4718
4719
4720
4721
4722
4723
4724
4725
4726
4727
4728
4729
4730
4731
4732
4733
4734
4735
4736
4737
4738
4739
4740
4741
4742
4743
4744
4745
4746
4747
4748
4749
4750
4751
4752
4753
4754
4755
4756
4757
4758
4759
4760
4761
4762
4763
4764
4765
4766
4767
4768
4769
4770
4771
4772
4773
4774
4775
4776
4777
4778
4779
4780
4781
4782
4783
4784
4785
4786
4787
4788
4789
4790
4791
4792
4793
4794
4795
4796
4797
4798
4799
4800
4801
4802
4803
4804
4805
4806
4807
4808
4809
4810
4811
4812
4813
4814
4815
4816
4817
4818
4819
4820
4821
4822
4823
4824
4825
4826
4827
4828
4829
4830
4831
4832
4833
4834
4835
4836
4837
4838
4839
4840
4841
4842
4843
4844
4845
4846
4847
4848
4849
4850
4851
4852
4853
4854
4855
4856
4857
4858
4859
4860
4861
4862
4863
4864
4865
4866
4867
4868
4869
4870
4871
4872
4873
4874
4875
4876
4877
4878
4879
4880
4881
4882
4883
4884
4885
4886
4887
4888
4889
4890
4891
4892
4893
4894
4895
4896
4897
4898
4899
4900
4901
4902
4903
4904
4905
4906
4907
4908
4909
4910
4911
4912
4913
4914
4915
4916
4917
4918
4919
4920
4921
4922
4923
4924
4925
4926
4927
4928
4929
4930
4931
4932
4933
4934
4935
4936
4937
4938
4939
4940
4941
4942
4943
4944
4945
4946
4947
4948
4949
4950
4951
4952
4953
4954
4955
4956
4957
4958
4959
4960
4961
4962
4963
4964
4965
4966
4967
4968
4969
4970
4971
4972
4973
4974
4975
4976
4977
4978
4979
4980
4981
4982
4983
4984
4985
4986
4987
4988
4989
4990
4991
4992
4993
4994
4995
4996
4997
4998
4999
5000
5001
5002
5003
5004
5005
5006
5007
5008
5009
5010
5011
5012
5013
5014
5015
5016
5017
5018
5019
5020
5021
5022
5023
5024
5025
5026
5027
5028
5029
5030
5031
5032
5033
5034
5035
5036
5037
5038
5039
5040
5041
5042
5043
5044
5045
5046
5047
5048
5049
5050
5051
5052
5053
5054
5055
5056
5057
5058
5059
5060
5061
5062
5063
5064
5065
5066
5067
5068
5069
5070
5071
5072
5073
5074
5075
5076
5077
5078
5079
5080
5081
5082
5083
5084
5085
5086
5087
5088
5089
5090
5091
5092
5093
5094
5095
5096
5097
5098
5099
5100
5101
5102
5103
5104
5105
5106
5107
5108
5109
5110
5111
5112
5113
5114
5115
5116
5117
5118
5119
5120
5121
5122
5123
5124
5125
5126
5127
5128
5129
5130
5131
5132
5133
5134
5135
5136
5137
5138
5139
5140
5141
5142
5143
5144
5145
5146
5147
5148
5149
5150
5151
5152
5153
5154
5155
5156
5157
5158
5159
5160
5161
5162
5163
5164
5165
5166
5167
5168
5169
5170
5171
5172
5173
5174
5175
5176
5177
5178
5179
5180
5181
5182
5183
5184
5185
5186
5187
5188
5189
5190
5191
5192
5193
5194
5195
5196
5197
5198
5199
5200
5201
5202
5203
5204
5205
5206
5207
5208
5209
5210
5211
5212
5213
5214
5215
5216
5217
5218
5219
5220
5221
5222
5223
5224
5225
5226
5227
5228
5229
5230
5231
5232
5233
5234
5235
5236
5237
5238
5239
5240
5241
5242
5243
5244
5245
5246
5247
5248
5249
5250
5251
5252
5253
5254
5255
5256
5257
5258
5259
5260
5261
5262
5263
5264
5265
5266
5267
5268
5269
5270
5271
5272
5273
5274
5275
5276
5277
5278
5279
5280
5281
5282
5283
5284
5285
5286
5287
5288
5289
5290
5291
5292
5293
5294
5295
5296
5297
5298
5299
5300
5301
5302
5303
5304
5305
5306
5307
5308
5309
5310
5311
5312
5313
5314
5315
5316
5317
5318
5319
5320
5321
5322
5323
5324
5325
5326
5327
5328
5329
5330
5331
5332
5333
5334
5335
5336
5337
5338
5339
5340
5341
5342
5343
5344
5345
5346
5347
5348
5349
5350
5351
5352
5353
5354
5355
5356
5357
5358
5359
5360
5361
5362
5363
5364
5365
5366
5367
5368
5369
5370
5371
5372
5373
5374
5375
5376
5377
5378
5379
5380
5381
5382
5383
5384
5385
5386
5387
5388
5389
5390
5391
5392
5393
5394
5395
5396
5397
5398
5399
5400
5401
5402
5403
5404
5405
5406
5407
5408
5409
5410
5411
5412
5413
5414
5415
5416
5417
5418
5419
5420
5421
5422
5423
5424
5425
5426
5427
5428
5429
5430
5431
5432
5433
5434
5435
5436
5437
5438
5439
5440
5441
5442
5443
5444
5445
5446
5447
5448
5449
5450
5451
5452
5453
5454
5455
5456
5457
5458
5459
5460
5461
5462
5463
5464
5465
5466
5467
5468
5469
5470
5471
5472
5473
5474
5475
5476
5477
5478
5479
5480
5481
5482
5483
5484
5485
5486
5487
5488
5489
5490
5491
5492
5493
5494
5495
5496
5497
5498
5499
5500
5501
5502
5503
5504
5505
5506
5507
5508
5509
5510
5511
5512
5513
5514
5515
5516
5517
5518
5519
5520
5521
5522
5523
5524
5525
5526
5527
5528
5529
5530
5531
5532
5533
5534
5535
5536
5537
5538
5539
5540
5541
5542
5543
5544
5545
5546
5547
5548
5549
5550
5551
5552
5553
5554
5555
5556
5557
5558
5559
5560
5561
5562
5563
5564
5565
5566
5567
5568
5569
5570
5571
5572
5573
5574
5575
5576
5577
5578
5579
5580
5581
5582
5583
5584
5585
5586
5587
5588
5589
5590
5591
5592
5593
5594
5595
5596
5597
5598
5599
5600
5601
5602
5603
5604
5605
5606
5607
5608
5609
5610
5611
5612
5613
5614
5615
5616
5617
5618
5619
5620
5621
5622
5623
5624
5625
5626
5627
5628
5629
5630
5631
5632
5633
5634
5635
5636
5637
5638
5639
5640
5641
5642
5643
5644
5645
5646
5647
5648
5649
5650
5651
5652
5653
5654
5655
5656
5657
5658
5659
5660
5661
5662
5663
5664
5665
5666
5667
5668
5669
5670
5671
5672
5673
5674
5675
5676
5677
5678
5679
5680
5681
5682
5683
5684
5685
5686
5687
5688
5689
5690
5691
5692
5693
5694
5695
5696
5697
5698
5699
5700
5701
5702
5703
5704
5705
5706
5707
5708
5709
5710
5711
5712
5713
5714
5715
5716
5717
5718
5719
5720
5721
5722
5723
5724
5725
5726
5727
5728
5729
5730
5731
5732
5733
5734
5735
5736
5737
5738
5739
5740
5741
5742
5743
5744
5745
5746
5747
5748
5749
5750
5751
5752
5753
5754
5755
5756
5757
5758
5759
5760
5761
5762
5763
5764
5765
5766
5767
5768
5769
5770
5771
5772
5773
5774
5775
5776
5777
5778
5779
5780
5781
5782
5783
5784
5785
5786
5787
5788
5789
5790
5791
5792
5793
5794
5795
5796
5797
5798
5799
5800
5801
5802
5803
5804
5805
5806
5807
5808
5809
5810
5811
5812
5813
5814
5815
5816
5817
5818
5819
5820
5821
5822
5823
5824
5825
5826
5827
5828
5829
5830
5831
5832
5833
5834
5835
5836
5837
5838
5839
5840
5841
5842
5843
5844
5845
5846
5847
5848
5849
5850
5851
5852
5853
5854
5855
5856
5857
5858
5859
5860
5861
5862
5863
5864
5865
5866
5867
5868
5869
5870
5871
5872
5873
5874
5875
5876
5877
5878
5879
5880
5881
5882
5883
5884
5885
5886
5887
5888
5889
5890
5891
5892
5893
5894
5895
5896
5897
5898
5899
5900
5901
5902
5903
5904
5905
5906
5907
5908
5909
5910
5911
5912
5913
5914
5915
5916
5917
5918
5919
5920
5921
5922
5923
5924
5925
5926
5927
5928
5929
5930
5931
5932
5933
5934
5935
5936
5937
5938
5939
5940
5941
5942
5943
5944
5945
5946
5947
5948
5949
5950
5951
5952
5953
5954
5955
5956
5957
5958
5959
5960
5961
5962
5963
5964
5965
5966
5967
5968
5969
5970
5971
5972
5973
5974
5975
5976
5977
5978
5979
5980
5981
5982
5983
5984
5985
5986
5987
5988
5989
5990
5991
5992
5993
5994
5995
5996
5997
5998
5999
6000
6001
6002
6003
6004
6005
6006
6007
6008
6009
6010
6011
6012
6013
6014
6015
6016
6017
6018
6019
6020
6021
6022
6023
6024
6025
6026
6027
6028
6029
6030
6031
6032
6033
6034
6035
6036
6037
6038
6039
6040
6041
6042
6043
6044
6045
6046
6047
6048
6049
6050
6051
6052
6053
6054
6055
6056
6057
6058
6059
6060
6061
6062
6063
6064
6065
6066
6067
6068
6069
6070
6071
6072
6073
6074
6075
6076
6077
-- Title:      ALVARION  Private MIB
--             This Private MIB supports BreezeAccess_VL, BreezeACCESS_4900 and BreezeNET-B product lines.
--
--
-- Version:    4.5.16
-- Date:       Tuesday August 14 2007
-- Comments:   ALVARION agents also support the following Public MIBs:

-- This MIB supports BreezeACCESS VL products (AU and SU), 
-- BreezeACCESS 4900 (AU and SU) and 
-- BreezeNET-B products (BU and RB). 
  
-- Some MIB compilers require that the following lines 
-- for proper compilation

--#include "rfc1155.smi"
--#include "rfc1212.smi"


-- mgmt           OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1)  mgmt(2) }
-- mib            OBJECT IDENTIFIER ::= { mgmt 1  }
-- directory      OBJECT IDENTIFIER ::= { internet 1  }
-- experimental   OBJECT IDENTIFIER ::= { internet 3  }
-- private        OBJECT IDENTIFIER ::= { internet 4  }
-- enterprises    OBJECT IDENTIFIER ::= { private 1  }

-- End of lines which might be needed to other MIB browsers 
-- for proper compilation


ALVARION-DOT11-WLAN-MIB DEFINITIONS ::= BEGIN


  IMPORTS
       MODULE-IDENTITY, NOTIFICATION-TYPE, enterprises, IpAddress,Counter32,OBJECT-TYPE
               FROM SNMPv2-SMI;

alvarion        	OBJECT IDENTIFIER ::= { enterprises 12394 }
products		    OBJECT IDENTIFIER ::= { alvarion 1 }

breezeAccessVLMib	MODULE-IDENTITY
		LAST-UPDATED	"0708141146Z"
		ORGANIZATION	"Alvarion Ltd."
		CONTACT-INFO	"Alvarion Customer Service
					     Postal: Alvarion Ltd.
					     Barzel 21
					     Tel Aviv 69710 
					     ISRAEL
		                 E-mail: CS_Coordinator@alvarion.com"
		DESCRIPTION		
		      "BreezeAccess VL, BreezeACCESS 4900 and BreezeNET-B"
		REVISION 	     "0708141146Z"
		DESCRIPTION		
		      "Version 4.5"
		::=  {  products 1 }

  		 
MacAddress ::= OCTET STRING (SIZE(6))
DisplayString ::= OCTET STRING 

alvarionOID     OBJECT IDENTIFIER ::= { alvarion      4 }
brzAccessVLOID  OBJECT IDENTIFIER ::= { alvarionOID   1 }


brzAccessVLAU     OBJECT IDENTIFIER ::= { brzAccessVLOID 1 }
brzAccessVLSU     OBJECT IDENTIFIER ::= { brzAccessVLOID 2 }

brzAccessVLAU-BS    OBJECT IDENTIFIER ::= { brzAccessVLOID 4 }
brzAccessVLAU-SA    OBJECT IDENTIFIER ::= { brzAccessVLOID 5 }

brzAccessVLAUS-BS   OBJECT IDENTIFIER ::= { brzAccessVLOID 6 }
brzAccessVLAUS-SA   OBJECT IDENTIFIER ::= { brzAccessVLOID 7 }
brzAccessAU-EZ		OBJECT IDENTIFIER ::= { brzAccessVLOID 8 }

brzAccessVLSU-6-1D   OBJECT IDENTIFIER ::= { brzAccessVLOID 11 }
brzAccessVLSU-6-BD   OBJECT IDENTIFIER ::= { brzAccessVLOID 12 }
brzAccessVLSU-24-BD  OBJECT IDENTIFIER ::= { brzAccessVLOID 13 }
brzAccessVLSU-BD     OBJECT IDENTIFIER ::= { brzAccessVLOID 14 }
brzAccessVLSU-54-BD  OBJECT IDENTIFIER ::= { brzAccessVLOID 15 }

brzAccessVLSU-3-1D  OBJECT IDENTIFIER ::= { brzAccessVLOID 16 }
brzAccessVLSU-3-4D  OBJECT IDENTIFIER ::= { brzAccessVLOID 17 }
brzAccessVLSU-I		OBJECT IDENTIFIER ::= { brzAccessVLOID 18 }

brzNetB-BU-B14     OBJECT IDENTIFIER ::= { brzAccessVLOID 21 }
brzNetB-BU-B28     OBJECT IDENTIFIER ::= { brzAccessVLOID 22 }
brzNetB-BU-B100    OBJECT IDENTIFIER ::= { brzAccessVLOID 23 }

brzNetB-RB-B14     OBJECT IDENTIFIER ::= { brzAccessVLOID 31 }
brzNetB-RB-B28     OBJECT IDENTIFIER ::= { brzAccessVLOID 32 }
brzNetB-RB-B100    OBJECT IDENTIFIER ::= { brzAccessVLOID 33 }

brzAccess4900-AU-BS OBJECT IDENTIFIER ::= { brzAccessVLOID 41 }
brzAccess4900-AU-SA OBJECT IDENTIFIER ::= { brzAccessVLOID 42 }
brzAccess4900-SU-BD OBJECT IDENTIFIER ::= { brzAccessVLOID 51 }

brzAccessVLProducts		OBJECT IDENTIFIER ::= {	brzAccessVLOID 3 }

-- ****************************************************************************************
-- ****************************************************************************************
-- General System Info
-- ===================
brzaccVLSysInfo       OBJECT IDENTIFIER ::= {breezeAccessVLMib 1}


    brzaccVLUnitHwVersion OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..32))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Hardware platform version."
            ::= { brzaccVLSysInfo 1 }

    brzaccVLRunningSoftwareVersion OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..32))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Running software version."
            ::= { brzaccVLSysInfo 2 }

    brzaccVLRunningFrom OBJECT-TYPE
            SYNTAX INTEGER { mainVersion(1) , shadowVersion(2)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The memory (main or shadow) from which the current version is 
             running from." 
            ::= { brzaccVLSysInfo 3 }

    brzaccVLMainVersionNumber OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..32))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Main software version number."
            ::= { brzaccVLSysInfo 4 }

    brzaccVLMainVersionFileName OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..32))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Main software version file name."
            ::= { brzaccVLSysInfo 5 }


    brzaccVLShadowVersionNumber OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..32))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Shadow software version number."
            ::= { brzaccVLSysInfo 6 }

    brzaccVLShadowVersionFileName OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..32))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Shadow software version file name."
            ::= { brzaccVLSysInfo 7 }

    brzaccVLUnitMacAddress OBJECT-TYPE
            SYNTAX  MacAddress
            MAX-ACCESS  read-only    
            STATUS  current
            DESCRIPTION
            "Applicable to all units.  
             Unit hardware MAC address."
            ::= { brzaccVLSysInfo 8 }

    brzaccVLUnitType OBJECT-TYPE
            SYNTAX INTEGER {auBS (1), auSA(2) , su-6-1D(3),su-6-BD(4),su-24-BD(5),
                            bu-B14(6),bu-B28(7),rb-B14(8),rb-B28(9),su-BD(10),su-54-BD (11),
                            su-3-1D(12),su-3-4D(13),ausBS(14),ausSA(15),
                            auBS4900(16),auSA4900(17),su4900(18), bu-B100(19), rb-B100(20), su-I(21), 
                            au-E(22) }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             auBS     (1) : AU-BS (modular access unit). 
             auSA     (2) : AU-SA (stand-alone access unit).
             su-6-1D  (3) : SU-6-1D (subscriber unit supporting 6 Mbps)
             su-6-BD  (4) : SU-6-BD (subscriber unit supporting 6 Mbps).
             su-24-BD (5) : SU-24-BD (subscriber unit supporting 24 Mbps).
			 bu-B14   (6) : BU-B14 (BreezeNET Base Unit supporting 14 Mbps).
			 bu-B28   (7) : BU-B28 (BreezeNET Base Unit supporting 28 Mbps).
			 rb-B14   (8) : RB-B14 (BreezeNET Remote Bridge supporting 14 Mbps).
			 rb-B28   (9) : RB-B28 (BreezeNET Remote Bridge supporting 28 Mbps).
			 su-BD   (10) : SU-BD (subscriber unit).
			 su-54-BD(11) : SU-54-BD (subscriber unit supporting 54 Mbps).
             su-3-1D (12) : SU-3-1D (subscriber unit supporting 3 Mbps).
             su-3-4D (13) : SU-3-4D (subscriber unit supporting 3 Mbps).
             ausBS   (14) : AUS-BS (modular access unit supporting maxim 8 or 25 
                            (via licensing) subscribers and allowing association 
                            only with SU-3 or SU-6).
             ausSA   (15) : AUS-SA (stand-alone access unit supporting maxim 8 or 25 
                            (via licensing) subscribers and allowing association 
                            only with SU-3 or SU-6 ).
             auBS4900(16) : AU-BS-4900 (BreezeAccess 4900 modular access unit)
             auSA4900(17) : AU-SA-4900 (BreezeAccess 4900 stand alone access unit)
             suBD4900(18) : SU-BD-4900 (BreezeAccess 4900 subscriber unit)
             bu-B100 (19) : BU-B100 (BreezeNET Base Unit unlimited throughput)
             rb-B100 (20) : BU-B100 (BreezeNET Remote Bridge unlimited throughput) 
             su-I    (21) : SU-I
             au-E    (22) : AU-E" 
             ::= { brzaccVLSysInfo 9 }

    brzaccVLAssociatedAU OBJECT-TYPE
            SYNTAX  MacAddress
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.  
             Associated AU/BU MAC address."
            ::= { brzaccVLSysInfo 10 }

    brzaccVLNumOfAssociationsSinceLastReset OBJECT-TYPE
            SYNTAX  INTEGER
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The number of associations since last reset, including 
             duplicate associations (re-associations)."
            ::= { brzaccVLSysInfo 11 }

    brzaccVLCurrentNumOfAssociations OBJECT-TYPE
            SYNTAX  INTEGER	
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to AU only.  
             Not applicable to BreezeNET-B products.
             The number of SUs currently associated with the AU.
             BreezeNET-B products return 65535."
            ::= { brzaccVLSysInfo 13 }

    brzaccVLUnitBootVersion OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..32))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Boot version."
            ::= { brzaccVLSysInfo 14 }

    brzaccVLRadioBand OBJECT-TYPE
			SYNTAX INTEGER {band-5-8GHz (1), band-5-4GHz (2) , band-4-9GHz (3),band-5-2GHz (4),band-2-4GHz (5),band-5-3GHz (6),band-4-9GHzJapan (7)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The unit's radio band."
            ::= { brzaccVLSysInfo 15 }

    brzaccVLCurrentEthernetPortState  OBJECT-TYPE
            SYNTAX  INTEGER	{ halfDuplexAnd10Mbps  (1),
            				  fullDuplexAnd10Mbps  (2),
							  halfDuplexAnd100Mbps (3),
							  fullDuplexAnd100Mbps (4),
							  linkDown             (5) }

            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The current Ethernet port state."
            ::= { brzaccVLSysInfo 16 }



    brzaccVLTimeSinceLastReset OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..32))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The elapsed time since last reset."
            ::= { brzaccVLSysInfo 17 }

brzaccVLCountryDependentParameters   OBJECT IDENTIFIER ::= {brzaccVLSysInfo 18}
	
    brzaccVLCountryCode OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..32))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             The country code and country name or country group name 
             that is supported by the unit."
            ::= { brzaccVLCountryDependentParameters 1 }

    brzaccVLCountryDependentParamsTable  OBJECT-TYPE
            SYNTAX SEQUENCE OF BrzaccVLCountryDependentParameterEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to all units. A table of country dependent parameters."
            ::= {brzaccVLCountryDependentParameters 2}

    brzaccVLCountryDependentParameterEntry OBJECT-TYPE
            SYNTAX BrzaccVLCountryDependentParameterEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to all units. 
             An entry in the Country Dependent Parameters table."  
             INDEX { brzaccVLCountryDependentParameterTableIdx }
            ::= { brzaccVLCountryDependentParamsTable 1 }

    BrzaccVLCountryDependentParameterEntry ::= SEQUENCE {
            brzaccVLCountryDependentParameterTableIdx     INTEGER,
            brzaccVLCountryDependentParameterFrequencies  DisplayString,
			brzaccVLAllowedBandwidth                      INTEGER,
			brzaccVLRegulationMaxTxPowerAtAntennaPort	  INTEGER,
			brzaccVLRegulationMaxEIRP					  INTEGER,
			brzaccVLMinModulationLevel                    INTEGER,
			brzaccVLMaxModulationLevel                    INTEGER,
			brzaccVLBurstModeSupport                      INTEGER,
			brzaccVLMaximumBurstDuration                  INTEGER,
			brzaccVLDfsSupport							  INTEGER,
			brzaccVLMinimumHwRevision                     INTEGER
            }
               
    brzaccVLCountryDependentParameterTableIdx  OBJECT-TYPE
            SYNTAX INTEGER  (1..5)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to all units. 
             The sub-band ID of the entry in the Country Dependent 
             Parameters table. Serves also as index for the table entry."
           ::= { brzaccVLCountryDependentParameterEntry 1 }

    brzaccVLCountryDependentParameterFrequencies   OBJECT-TYPE
            SYNTAX DisplayString  
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to all units. 
             The frequencies included in the applicable sub-band entry."
           ::= { brzaccVLCountryDependentParameterEntry 2 }
	
    brzaccVLAllowedBandwidth   OBJECT-TYPE
            SYNTAX INTEGER  
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to all units. 
             The bandwidth when using the applicable the sub-band."
           ::= { brzaccVLCountryDependentParameterEntry 3 }

    brzaccVLRegulationMaxTxPowerAtAntennaPort  OBJECT-TYPE
            SYNTAX INTEGER  
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to all units. 
             The maximum allowed Tx power when using the applicable sub-band.
             A RegulationMaxTxPowerAtAntennaPort of 255, means no limit"
           ::= { brzaccVLCountryDependentParameterEntry 4 }
 
    brzaccVLRegulationMaxEIRP   OBJECT-TYPE
            SYNTAX INTEGER  
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to all units.
             The maximum Tx EIRP 
             when using the applicable sub-band.
             A Regulation Max EIRP of 0, means no limit."
           ::= { brzaccVLCountryDependentParameterEntry 5 }


    brzaccVLMinModulationLevel  OBJECT-TYPE
            SYNTAX INTEGER {  level1 (1), 
                              level2 (2), 
                              level3 (3), 
                              level4 (4), 
                              level5 (5), 
                              level6 (6), 
                              level7 (7),
                              level8 (8)
                            } 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to all units. 
             The minimum supported modulation level."
           ::= { brzaccVLCountryDependentParameterEntry 6 }

    brzaccVLMaxModulationLevel  OBJECT-TYPE
            SYNTAX INTEGER {  level1 (1), 
                              level2 (2), 
                              level3 (3), 
                              level4 (4), 
                              level5 (5), 
                              level6 (6), 
                              level7 (7),
                              level8 (8)
                            } 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to all units. 
             The maximum supported modulation level."
           ::= { brzaccVLCountryDependentParameterEntry 7 }
	
    brzaccVLBurstModeSupport  OBJECT-TYPE
            SYNTAX INTEGER  {supported(1), notSupported(2)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to all units. 
             The supported Burst Mode Option."
           ::= { brzaccVLCountryDependentParameterEntry 8}

    brzaccVLMaximumBurstDuration   OBJECT-TYPE
            SYNTAX INTEGER 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to all units. 
             Applicable only if Burst Mode Option is supported. 
             The maximum supported burst duration."
           ::= { brzaccVLCountryDependentParameterEntry 9}

	 
    brzaccVLDfsSupport  OBJECT-TYPE
            SYNTAX INTEGER  {supported(1), notSupported(2)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to AU/BU only. 
             The supported Dfs Option."
           ::= { brzaccVLCountryDependentParameterEntry 10}
	
    brzaccVLMinimumHwRevision  OBJECT-TYPE
            SYNTAX INTEGER {hwRevisionA (1), hwRevisionB (2), 
                            hwRevisionC (3), hwRevisionD (4), 
                            hwRevisionE (5), na (255)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to all units. 
             The Minimum HW Revision needed to support the country code."
           ::= { brzaccVLCountryDependentParameterEntry 11}
 

    brzaccVLAuthenticationEncryptionSupport OBJECT-TYPE
            SYNTAX INTEGER  {supported(1), notSupported(2)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             The supported Authentication Encryption Option."
            ::= { brzaccVLCountryDependentParameters 3 }

    brzaccVLDataEncryptionSupport OBJECT-TYPE
            SYNTAX INTEGER  {supported(1), notSupported(2)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             The supported Data Encryption Option."
            ::= { brzaccVLCountryDependentParameters 4 }

    brzaccVLAESEncryptionSupport OBJECT-TYPE
            SYNTAX INTEGER  {supported(1), notSupported(2)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             The supported AES Encryption Option."
            ::= { brzaccVLCountryDependentParameters 5 }

    brzaccVLAntennaGainChange OBJECT-TYPE
            SYNTAX INTEGER {supported(1), notSupported(2)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Indicates whether the Antenna Gain parameter is changeable or fixed." 
            ::= { brzaccVLSysInfo 19 }

    brzaccVLAteTestResults OBJECT-TYPE
            SYNTAX INTEGER { none(0), pass(1), fail(2) }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
            Results of ATE Test " 
            ::= { brzaccVLSysInfo 20 }
            
    brzaccVLSerialNumber OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..35))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
            Serial Number of the unit" 
            ::= { brzaccVLSysInfo 21 }

-- Unit Control
-- ============
brzaccVLUnitControl       OBJECT IDENTIFIER ::= {breezeAccessVLMib 2}

    brzaccVLResetUnit OBJECT-TYPE
            SYNTAX  INTEGER { cancel (1), resetSystemNow (2) }  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Resets the unit and applies new parameter values."
            ::= { brzaccVLUnitControl 1 }


    brzaccVLSetDefaults OBJECT-TYPE
            SYNTAX  INTEGER {  noDefaultSettingRequested (0),
                               completeFactory  (1), 
                               partialFactory   (2), 
                               completeOperator (3), 
                               partialOperator  (4), 
                               cancelCurrentPendingRequest(5) }  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Sets unit configuration to Defaults values after the 
             next reset.    
             noDefaultSettingRequested : Read-Only Option, no Default setting was Issued.
             completeFactory : All parameters revert to Factory 
                               Defaults values.
             partialFactory  : All parameters revert to Factory 
                               Defaults values, except the parameters 
                               required for maintaining wireless 
                               connectivity.    
             completeOperator: All parameters revert to Operator 
                               Defaults values. 
             partialOperator : All parameters revert to Operator 
                               Defaults values, except the parameters 
                               required for maintaining wireless 
                               connectivity.
             cancelCurrentPendingRequest : Default Setting request is cancelled."
            ::= { brzaccVLUnitControl 2 }

    brzaccVLUnitName OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..32))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The unit name. 
             A string of up to 32 printable ASCII characters."
            ::= { brzaccVLUnitControl 3 }

    brzaccVLFlashMemoryControl OBJECT-TYPE
            SYNTAX  INTEGER { resetAndBootFromShadowVersion (1), 
                              useRunningVersionAfterReset (2),cancel(3) }  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             resetAndBootFromShadowVersion : Activates the backup 
                                             version.   
             useRunningVersionAfterReset   : The currently active 
                                             version will become the main 
                                             version and will be activated 
                                             after next reset."
            ::= { brzaccVLUnitControl 4 }


    brzaccVLTelnetLogoutTimer  OBJECT-TYPE
            SYNTAX  INTEGER   
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Time-out of management via Telnet program. 
             Automatic exit if the program is inactive for the 
             defined time.
             Range: 1 to 999 (minutes)."
            ::= { brzaccVLUnitControl 5 }

    brzaccVLSaveCurrentConfigurationAsOperatorDefaults OBJECT-TYPE
            SYNTAX  INTEGER { saveAsDefaults (1),cancel(2) }  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Saves the current configuration as Operator Defaults.
             Cannot be executed after requesting set defaults 
             and the unit was not reset."
            ::= { brzaccVLUnitControl 6 }

    brzaccVLExitTelnet OBJECT-TYPE
            SYNTAX  INTEGER { cancelOperation (1), exit (2)}  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Exit the management via Telnet program."
            ::= { brzaccVLUnitControl 7 }

brzaccVLUnitPasswords     OBJECT IDENTIFIER ::= {brzaccVLUnitControl 8}

    brzaccVLReadOnlyPassword OBJECT-TYPE
            SYNTAX DisplayString (SIZE(1..8))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units. 
             The User (read only) password.
             This is also the Read Community String.
             Up to 8 printable ASCII characters."
            ::= { brzaccVLUnitPasswords 1 }

    brzaccVLInstallerPassword OBJECT-TYPE
            SYNTAX DisplayString (SIZE(1..8))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units. 
             The Installer password.
             Up to 8 printable ASCII characters."
            ::= { brzaccVLUnitPasswords 2 }

    brzaccVLAdminPassword OBJECT-TYPE
            SYNTAX DisplayString (SIZE(1..8))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units. 
            The Administrator password. Accessible only with SNMP Write 
            Community String (administrator password). 
            Up to 8 printable ASCII characters."
            ::= { brzaccVLUnitPasswords 3 }


    brzaccVLEthernetNegotiationMode  OBJECT-TYPE
            SYNTAX INTEGER { force10MbpsAndHalfDuplex   (1),
            				 force10MbpsAndFullDuplex   (2),
							 force100MbpsAndHalfDuplex  (3),
							 force100MbpsAndFullDuplex  (4),
							 autoNegotiationMode        (5) }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The speed/duplex mode of the Ethernet port." 
            ::= { brzaccVLUnitControl 9 }

brzaccVLFTPParameters      OBJECT IDENTIFIER ::= {brzaccVLUnitControl 10}

brzaccVLFTPServerParams      OBJECT IDENTIFIER ::= {brzaccVLFTPParameters 1}

    brzaccVLFTPServerUserName OBJECT-TYPE
            SYNTAX  DisplayString (SIZE(0..18))  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units. 
             The user name to be used for access to the FTP server. 
             Accessible only with SNMP Write Community String 
             (administrator password)." 
            ::= { brzaccVLFTPServerParams 1 }

    brzaccVLFTPServerPassword OBJECT-TYPE
            SYNTAX  DisplayString (SIZE(0..18))  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units. 
             The password to be used for access to the FTP server. 
             Accessible only with SNMP Write Community String 
             (administrator password)." 
            ::= { brzaccVLFTPServerParams 2 }

    brzaccVLFTPClientIPAddress OBJECT-TYPE
            SYNTAX  IpAddress  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             For SW version higher than 4.0 this is read-only. 
             The IP address of the FTP stack in the unit." 
            ::= { brzaccVLFTPServerParams 3 }  

    brzaccVLFTPServerIpAddress OBJECT-TYPE
            SYNTAX  IpAddress  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The IP address of the FTP server." 
            ::= { brzaccVLFTPServerParams 4 }  

    brzaccVLFTPClientMask OBJECT-TYPE
            SYNTAX  IpAddress  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The Mask of the FTP stack in the unit." 
            ::= { brzaccVLFTPServerParams 5 }  


    brzaccVLFTPGatewayIpAddress OBJECT-TYPE
            SYNTAX  IpAddress  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The FTP Gateway address"
            ::= { brzaccVLFTPServerParams 6 }  


brzaccVLFTPSwDownload      OBJECT IDENTIFIER ::= {brzaccVLFTPParameters 2}

   brzaccVLFTPSwFileName  OBJECT-TYPE
            SYNTAX DisplayString (SIZE(1..20))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The name of the SW file to be downloaded."
            ::= { brzaccVLFTPSwDownload 1 }

   brzaccVLFTPSwSourceDir  OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..80))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The source directory of the required file in the FTP server.
             Up to 80 printable ASCII characters.
             Use dot (.) To clear field"
            ::= { brzaccVLFTPSwDownload 2 }

    brzaccVLFTPDownloadSwFile OBJECT-TYPE
            SYNTAX  INTEGER { downloadFile (1) , cancel (2)}  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Execution  of the SW download operation" 
            ::= { brzaccVLFTPSwDownload 3 }

brzaccVLConfigurationFileLoading      OBJECT IDENTIFIER ::= {brzaccVLFTPParameters 3}

   brzaccVLConfigurationFileName  OBJECT-TYPE
            SYNTAX DisplayString (SIZE(1..20))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The name of the configuration file to be downloaded/uploaded."
            ::= { brzaccVLConfigurationFileLoading 1 }

   brzaccVLOperatorDefaultsFileName  OBJECT-TYPE
            SYNTAX DisplayString (SIZE(1..20))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The name of the Operator Defaults file to be downloaded/uploaded"
            ::= { brzaccVLConfigurationFileLoading 2 }

   brzaccVLFTPConfigurationFileSourceDir  OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..80))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The source directory of the required file in the FTP server.
             Up to 80 printable ASCII characters.
             Use dot (.) To clear field"
            ::= { brzaccVLConfigurationFileLoading 3 }

    brzaccVLExecuteFTPConfigurationFileLoading OBJECT-TYPE
            SYNTAX  INTEGER {executeFTPGetConfigurationFile (1), executeFTPPutConfigurationFile (2),
							 executeFTPGetOperatorDefaults  (3) , executeFTPPutOperatorDefaults (4), cancel (5) }  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Execution of the file download/upload operation." 
            ::= { brzaccVLConfigurationFileLoading 4 }



brzaccVLEventLogFileUploading   OBJECT IDENTIFIER ::= {brzaccVLFTPParameters 4}

   brzaccVLEventLogFileName  OBJECT-TYPE
            SYNTAX DisplayString (SIZE(1..20))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The name of the Event Log file to be uploaded."
            ::= { brzaccVLEventLogFileUploading 1 }

   brzaccVLEventLogDestinationDir  OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..80))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The destination directory of the event log file.
             Up to 80 printable ASCII characters.
             Use dot (.) To clear field."
            ::= { brzaccVLEventLogFileUploading 2 }

    brzaccVLUploadEventLogFile OBJECT-TYPE
            SYNTAX  INTEGER { uploadFile (1) , cancel (2)}  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Execution  of the event log upload operation." 
            ::= { brzaccVLEventLogFileUploading 3 }

    brzaccVLLoadingStatus OBJECT-TYPE
            SYNTAX  INTEGER {inProcess (1), successful (2), failed (3)}  
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The status of the last loading operation."
            ::= { brzaccVLUnitControl 11 }

brzaccVLEventLogFileParams   OBJECT IDENTIFIER ::= {brzaccVLUnitControl 12}

   brzaccVLEventLogPolicy  OBJECT-TYPE
            SYNTAX INTEGER {message (1), warning (2), error (3),fatal(4), logNone(5)}
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
              The lowest level event to be registered in the event log."
            ::= { brzaccVLEventLogFileParams 1 }

   brzaccVLEraseEventLog  OBJECT-TYPE
            SYNTAX INTEGER { eraseEventLog (1),cancel(2) }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
              Erase the event log."
            ::= { brzaccVLEventLogFileParams 2 }

    brzaccVLSystemLocation OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..34))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The unit location."
            ::= { brzaccVLUnitControl 13 }

brzaccVLFeatureUpgrade   OBJECT IDENTIFIER ::= {brzaccVLUnitControl 14}
   
    brzaccVLFeatureUpgradeManually OBJECT-TYPE
            SYNTAX DisplayString (SIZE(32..64))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Upgrade unit to support new feature. Enter your license number 
             (32 to 64 hex digits)."
            ::= { brzaccVLFeatureUpgrade 1 }

    brzaccVLChangeUnitType  OBJECT-TYPE
            SYNTAX INTEGER { bu(1), rb(2), cancel(3) }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable RB/BU only.  
             Change the unit type between BU and RB."
            ::= { brzaccVLUnitControl 15 }

   brzaccLighteAPWorkingMode OBJECT-TYPE
        	SYNTAX  INTEGER  
        	MAX-ACCESS read-write
        	STATUS current
        	DESCRIPTION 
        	"Applicable to AU only. 
         	Change unit running mode: 0 - VL mode 1 - Mixed cell mode" 
			::= { brzaccVLUnitControl 16 }

            
-- Network Management Params
-- =========================
   brzaccVLNwMngParameters   OBJECT IDENTIFIER ::= {breezeAccessVLMib 3}

    brzaccVLAccessToNwMng OBJECT-TYPE
           SYNTAX   INTEGER { fromWirelessOnly  (1), 
                              fromEthernetOnly (2), 
                              fromBothWirelessAndEthernet  (3), 
                              na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to all units.  
             The port to be used for remote management."
            ::= { brzaccVLNwMngParameters 1 }


    brzaccVLNwMngFilter OBJECT-TYPE
             SYNTAX INTEGER { disable (1),
                              activateOnEthernetPort (2), 
                              activateOnWirelessPort  (3), 
                              activateOnBothWirelessAndEthernet  (4), 
                              na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to all units.  
             Disables or enable on one of the ports, or on both 
             ports, IP address based filtering of management messages 
             (e.g. SNMP , Telnet , TFTP , DHCP)."
           ::= { brzaccVLNwMngParameters 2 }




    mngIpFilterTable OBJECT-TYPE
            SYNTAX SEQUENCE OF MngIpFilterEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to all units.  
             A Management IP Filter Table of up to 3 IP addresses 
             of devices that are authorized to access the unit 
             for management purposes." 
            ::= { brzaccVLNwMngParameters 3 }

    mngIpFilterEntry  OBJECT-TYPE
            SYNTAX MngIpFilterEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to all units.  
             A Management IP Filter Table entry."
            INDEX { brzaccVLNwMngIpTableIdx }
            ::= { mngIpFilterTable 1 }

    MngIpFilterEntry ::= SEQUENCE { brzaccVLNwMngIpAddress   IpAddress,
                                    brzaccVLNwMngIpTableIdx  INTEGER }
   
    brzaccVLNwMngIpAddress   OBJECT-TYPE
            SYNTAX IpAddress  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to all units.  
             An IP address in the Management IP Filter Table."
          ::= { mngIpFilterEntry 1 }

    brzaccVLNwMngIpTableIdx   OBJECT-TYPE
            SYNTAX INTEGER (1..10) 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to all units.  
             A table index for an entry in the Management IP Filter 
             Table."
         ::= { mngIpFilterEntry 2 }


    brzaccVLDeleteOneNwIpAddr OBJECT-TYPE
            SYNTAX  INTEGER (0 | 1..10 | 255) 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to all units.  
             0 - cancel operation.
             1..10 - Deletes a single selected entry from the Management IP 
             Filter Table."
            ::= { brzaccVLNwMngParameters 4 }

    brzaccVLDeleteAllNwIpAddrs OBJECT-TYPE
            SYNTAX INTEGER { deleteAll (1), cancelOperation (2), na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to all units.  
             Deletes all entries from the Management IP Filter Table."
            ::= { brzaccVLNwMngParameters 5 }

    brzaccVLAccessToNwTrap OBJECT-TYPE
            SYNTAX INTEGER { disable(1), enable(2) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to all units.  
             Enables or disables sending of traps."
            ::= { brzaccVLNwMngParameters 6 }

    mngTrapTable OBJECT-TYPE
            SYNTAX SEQUENCE OF MngTrapEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to all units.  
             A Management Trap Table of up to 10 IP addresses of 
             stations to send traps to." 
            ::= { brzaccVLNwMngParameters 7 }

    mngTrapEntry  OBJECT-TYPE
            SYNTAX MngTrapEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to all units.  
             A Management Trap Table entry." 
            INDEX { brzaccVLNwTrapTableIdx }
            ::= { mngTrapTable 1 }
                                
    MngTrapEntry ::= SEQUENCE { brzaccVLNwMngTrapCommunity DisplayString,
                                brzaccVLNwMngTrapAddress   IpAddress,
                                brzaccVLNwTrapTableIdx     INTEGER }
                                
    brzaccVLNwMngTrapCommunity OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..14))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The trap community associated with the applicable 
             entry in the Management Trap Table.
             Up to 14 printable case sensitive ASCII characters."
            ::= { mngTrapEntry 1 }

    brzaccVLNwMngTrapAddress   OBJECT-TYPE
            SYNTAX  IpAddress  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             An IP address in the Management Trap Table entry." 
        ::= { mngTrapEntry 2 }

    brzaccVLNwTrapTableIdx   OBJECT-TYPE
            SYNTAX  INTEGER (1..10) 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Tables Index for an entry in the Management Trap Table."
        ::= { mngTrapEntry 3 }


    brzaccVLDeleteOneTrapAddr OBJECT-TYPE
            SYNTAX  INTEGER (0 | 1..10 | 255)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             0 - cancel operation.
             1..10 - Deletes a single selected entry from the Management 
             Trap Table."
            ::= { brzaccVLNwMngParameters 8 }


    brzaccVLDeleteAllTrapAddrs OBJECT-TYPE
            SYNTAX  INTEGER { deleteAll (1),cancelOperation (2),  na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Deletes all entries from the Management Trap Table."
            ::= { brzaccVLNwMngParameters 9 }

	brzaccVLMngIpRangesTable OBJECT-TYPE
            SYNTAX SEQUENCE OF BrzaccVLMngIpRangeEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to all units.  
             Table of Management IP Address Ranges" 
            ::= { brzaccVLNwMngParameters 10 }

    brzaccVLMngIpRangeEntry  OBJECT-TYPE
            SYNTAX BrzaccVLMngIpRangeEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to all units.  
             A Management IP Address Ranges Table entry" 
            INDEX { brzaccVLMngIpRangeIdx }
            ::= { brzaccVLMngIpRangesTable 1 }
                                
    BrzaccVLMngIpRangeEntry ::= SEQUENCE { 
								brzaccVLMngIpRangeIdx		INTEGER,
								brzaccVLMngIpRangeFlag		INTEGER,					
                                brzaccVLMngIpRangeStart     IpAddress,
                                brzaccVLMngIpRangeEnd		IpAddress,
                                brzaccVLMngIpRangeMask		IpAddress
                                }
               
 
    brzaccVLMngIpRangeIdx OBJECT-TYPE
            SYNTAX  INTEGER (1..10)  
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Index of an entry in the Management IP Address Ranges Table"
            ::= { brzaccVLMngIpRangeEntry 1 }

    brzaccVLMngIpRangeFlag OBJECT-TYPE
            SYNTAX  INTEGER { rangeDefinedByStartEndAddr(1), rangeDefinedByStartAddrMask(2)}  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Defines the method of defining the range:
             Using Start & End Address( rangeDefinedByStartEndAddr ),
             or using Start Address and Mask ( rangeDefinedByStartAddrSubNetMask )."
            ::= { brzaccVLMngIpRangeEntry 2 }

    
    brzaccVLMngIpRangeStart OBJECT-TYPE
            SYNTAX  IpAddress
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Start Address of the range"
            ::= { brzaccVLMngIpRangeEntry 3 }
    
    brzaccVLMngIpRangeEnd OBJECT-TYPE
            SYNTAX  IpAddress
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             End Address of the range. 
             Used only if brzaccVLMngIpRangeFlag is  rangeDefinedByStartEndAddr"
            ::= { brzaccVLMngIpRangeEntry 4 }
            
	brzaccVLMngIpRangeMask OBJECT-TYPE
            SYNTAX  IpAddress
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
			"Applicable to all units.  
             End Address of the range. 
             Used only if brzaccVLMngIpRangeFlag is  rangeDefinedByStartAddrMask"
            ::= { brzaccVLMngIpRangeEntry 5 } 
            
	brzaccVLDeleteOneNwIpRange OBJECT-TYPE
            SYNTAX  INTEGER (0 | 1..10 | 255) 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to all units.  
             0 - cancel operation.
             1..10 - Deletes a single selected entry from the Management IP 
             Ranges Table."
            ::= { brzaccVLNwMngParameters 11 }
            
    
	brzaccVLDeleteAllNwIpRanges OBJECT-TYPE
            SYNTAX INTEGER { deleteAll (1), cancelOperation (2), na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to all units.  
             Deletes all entries from the Management IP Ranges Table."
            ::= { brzaccVLNwMngParameters 12 }

	brzaccVLApClientIpAddress    OBJECT-TYPE
            SYNTAX  IpAddress
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB unit only.  
             The IP Address of the WIFI WIMAX unit"
            ::= { brzaccVLNwMngParameters 13 }
                                      
-- IP Params:
-- ===========
brzaccVLIpParams      OBJECT IDENTIFIER ::= {breezeAccessVLMib 4}

    brzaccVLUnitIpAddress OBJECT-TYPE
            SYNTAX  IpAddress  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             IP address of the unit."
            ::= { brzaccVLIpParams 1 }

    brzaccVLSubNetMask OBJECT-TYPE
            SYNTAX  IpAddress  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Subnet mask of the unit."
            ::= { brzaccVLIpParams 2 }

    brzaccVLDefaultGWAddress OBJECT-TYPE
            SYNTAX  IpAddress  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Default gateway IP address of the unit."
            ::= { brzaccVLIpParams 3 }

    brzaccVLUseDhcp OBJECT-TYPE
            SYNTAX  INTEGER{ disable (1), 
                             dhcpOnly (2), 
                             automatic (3) }
            MAX-ACCESS  read-write    
            STATUS  current
            DESCRIPTION
            "Applicable to all units.  
             DHCP client mode of operation. 
             disabled : Use regular (manual) methods to configure IP 
                        parameters. 
             dHCP Only: Use DHCP server to configure IP parameters. 
             automatic: Use DHCP server to configure IP parameters. 
                        If a DHCP server is not available, use 
                        manually configured values."
            ::= { brzaccVLIpParams 4 }

    brzaccVLAccessToDHCP OBJECT-TYPE
            SYNTAX  INTEGER{ fromWirelessOnly    (1),
                             fromEthernetOnly (2),
                             fromBothWirelessAndEthernet (3) }
            MAX-ACCESS  read-write    
            STATUS  current
            DESCRIPTION
            "Applicable to all units.  
             The port to be used for communicating with a DHCP server."
            ::= { brzaccVLIpParams 5 }

    brzaccVLRunTimeIPaddr OBJECT-TYPE
            SYNTAX  IpAddress
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
            "Applicable to all units.  
             The run-time IP address. If DHCP is used the Run Time 
             IP Address is the address given to the unit by the 
             server. Otherwise it is the manually configured address."
            ::= { brzaccVLIpParams 6 }

    brzaccVLRunTimeSubNetMask OBJECT-TYPE
            SYNTAX  IpAddress
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
            "Applicable to all units.  
             The run-time Subnet Mask. If DHCP is used the Run Time 
             Subnet Mask is the mask given to the unit by the server. 
             Otherwise it is the manually configured mask."
            ::= { brzaccVLIpParams 7 }

    brzaccVLRunTimeDefaultIPGateway OBJECT-TYPE
            SYNTAX  IpAddress
            MAX-ACCESS  read-only
            STATUS  current
            DESCRIPTION
            "Applicable to all units.  
             The run-time Gateway IP address. If DHCP is used the 
             Run Time Gateway IP Address is the address given to the 
             unit by the server. Otherwise it is the manually 
             configured address."
            ::= { brzaccVLIpParams 8 }


-- Bridge Params
-- ==============
brzaccVLBridgeParameters      OBJECT IDENTIFIER ::= {breezeAccessVLMib 5}


brzaccVLVLANSupport       OBJECT IDENTIFIER ::= {brzaccVLBridgeParameters 1}

    brzaccVLVlanID OBJECT-TYPE
            SYNTAX  INTEGER 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             VLAN ID for data frame tagging. 
             Applicable to Access Link only. 
             Range: 1 to 4094. 0 - not applicable."
            ::= { brzaccVLVLANSupport 1 }

    brzaccVLEthernetLinkType OBJECT-TYPE
            SYNTAX  INTEGER { accessLink (1), 
                              trunkLink (2), 
                              hybridLink (3),
                              serviceProviderLink (4) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             VLAN support mode (Link Type). 
             The Access Link option is not available for AU/BU.
             Service Provider Link is not available for BU/RB."
            ::= { brzaccVLVLANSupport 2 }
 
    brzaccVLManagementVlanID OBJECT-TYPE
            SYNTAX  INTEGER 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             VLAN ID for management frame tagging.
             Range: 1 to 4094, 65535 for No VLAN tagging."
            ::= { brzaccVLVLANSupport 3 }

brzaccVLVLANForwarding        OBJECT IDENTIFIER ::= {brzaccVLVLANSupport 4}

     brzaccVLVlanForwardingSupport OBJECT-TYPE
            SYNTAX  INTEGER { disable (1) , enable (2), na(255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Enables or disables the VLAN forwarding feature. 
             (applicable in Trunk and Service Provider links only)."
            ::= { brzaccVLVLANForwarding 1 }

    brzaccVLVlanForwardingTable OBJECT-TYPE
            SYNTAX SEQUENCE OF BrzaccVLVlanForwardingEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to all units.  
             A VLAN Forwarding Table of up to 20 VLAN IDs of devices 
             to which data frames are forwarded when VLAN Forwarding 
             is Enabled. (applicable in Trunk and Service Provider links only)."
            ::= { brzaccVLVLANForwarding 2 }

    brzaccVLVlanForwardingEntry  OBJECT-TYPE
            SYNTAX BrzaccVLVlanForwardingEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to all units.  
             A VLAN Forwarding Table entry. (applicable in Trunk and Service Provider 
             links only)."
            INDEX { brzaccVLVlanForwardingTableIdx }
            ::= { brzaccVLVlanForwardingTable 1 }

    BrzaccVLVlanForwardingEntry ::= SEQUENCE {
            brzaccVLVlanForwardingTableIdx  INTEGER,
            brzaccVLVlanIdForwarding  INTEGER
            }

         
    brzaccVLVlanForwardingTableIdx   OBJECT-TYPE
            SYNTAX  INTEGER  (1..20)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             A read only table index for a VLAN entry in the VLAN 
             Forwarding Table."
        ::= { brzaccVLVlanForwardingEntry 1 }

    brzaccVLVlanIdForwarding   OBJECT-TYPE
            SYNTAX  INTEGER  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The list of VLAN ID's in the VLAN ID Forwarding Table. 
             To Remove a VLAN ID - SET the corresponding entry to 0. 
             To Add a new VLAN ID SET an entry which is currently 0.
             Range : 0 to 4094"
        ::= { brzaccVLVlanForwardingEntry 2 }
 
brzaccVLVlanRelaying    OBJECT IDENTIFIER ::= {brzaccVLVLANSupport 5}

    brzaccVLVlanRelayingSupport OBJECT-TYPE
            SYNTAX  INTEGER { disable (1) , enable (2), na(255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU only. 
             Not applicable to BreezeNET-B products. 
             Enables or disables VLAN Relaying (applicable in 
             Trunk and Service Provider links only)."
            ::= { brzaccVLVlanRelaying 1 }

    brzaccVLVlanRelayingTable OBJECT-TYPE
            SYNTAX SEQUENCE OF BrzaccVLVlanRelayingEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to AU only. 
			 Not applicable to BreezeNET-B products.
             A VLAN Relaying Table of up to 20 VLAN IDs of devices 
             to which data frames are relayed when VLAN Relaying is 
             Enabled. (applicable in Trunk and Service Provider links only)."
            ::= { brzaccVLVlanRelaying 2 }

    brzaccVLVlanRelayingEntry  OBJECT-TYPE
            SYNTAX BrzaccVLVlanRelayingEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to AU only.
             Not applicable to BreezeNET-B products. 
             A VLAN Relaying Table entry. (applicable in Trunk and Service 
             Provider links only)."
            INDEX { brzaccVLVlanRelayingTableIdx }
            ::= { brzaccVLVlanRelayingTable 1 }

    BrzaccVLVlanRelayingEntry ::= SEQUENCE {
            brzaccVLVlanRelayingTableIdx  INTEGER,
            brzaccVLVlanIdRelaying  INTEGER
            }
   
    brzaccVLVlanRelayingTableIdx   OBJECT-TYPE
            SYNTAX  INTEGER  (1..20)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to AU only. 
             Not applicable to BreezeNET-B products.
             A table index for a VLAN entry in the VLAN 
             Relaying Table."
        ::= { brzaccVLVlanRelayingEntry 1 }


    brzaccVLVlanIdRelaying   OBJECT-TYPE
            SYNTAX  INTEGER  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU only. 
             Not applicable to BreezeNET-B products.
             The list of VLAN ID's in the VLAN ID Relaying Table. 
             To Remove a VLAN ID - SET the corresponding entry to 0. 
             To Add a new VLAN ID SET an entry which is currently 0.
             Range: 0 to 4094 , 0 - remove entry."
        ::= { brzaccVLVlanRelayingEntry 2 }


brzaccVLVLANTrafficPriority       OBJECT IDENTIFIER ::= {brzaccVLVLANSupport 6}

    brzaccVLVlanDataPriority OBJECT-TYPE
            SYNTAX  INTEGER  { na(255) }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only. 
             Priority tagging for data frames. Applicable to Access 
             Link only.
             Range: 0 to 7."
            ::= { brzaccVLVLANTrafficPriority 1 }
  
    brzaccVLVlanManagementPriority OBJECT-TYPE
            SYNTAX  INTEGER  { na(255) }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Priority tagging for management frames. Applicable to 
             Access Link and Trunk Link only.
             Range: 0 to 7."
            ::= { brzaccVLVLANTrafficPriority 2 }

 
    brzaccVLVlanPriorityThreshold OBJECT-TYPE
            SYNTAX  INTEGER  { na(255) }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units. Not applicable to units with SW 
             version 3.1 or higher. 
             Priority threshold for tagged frames received from 
             Ethernet port. Applicable to Hybrid Link and Trunk Link 
             only.
             Valid values: 0-7."
            ::= { brzaccVLVLANTrafficPriority 3 }
            
	brzaccVLVLANQinQ	OBJECT IDENTIFIER ::= {brzaccVLVLANSupport 7}
	
	brzaccVLQinQEthertype   OBJECT-TYPE
            SYNTAX	INTEGER  (33025 .. 36864|37120|37376)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU and SU. Not applicable to BreezeNET-B units. 
            The Ethernet type of the Service Provider Tag.
            The range is  0x8101(33025) - 0x9000(36864), 0x9100(37120), 0x9200(37376)."
        ::= { brzaccVLVLANQinQ 1 }
        
	brzaccVLQinQProviderVlanID   OBJECT-TYPE
            SYNTAX	INTEGER (1..4094)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU only.
            VLAN ID of the Service Provider Tag."
        ::= { brzaccVLVLANQinQ 2 }
	
    brzaccVLBridgeAgingTime OBJECT-TYPE
            SYNTAX  INTEGER  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             Bridge aging time for devices on both the Ethernet and 
             wireless link sides. 
             Range: 20 to 2000 seconds."
            ::= { brzaccVLBridgeParameters 2 }

    brzaccVLBroadcastRelaying OBJECT-TYPE
            SYNTAX  INTEGER  {	disable (1),
								broadcastMulticastEnable (2),
								broadcastEnable (3),
								multicastEnable (4),
								na (255) }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU only. 
             Not applicable to BreezeNET-B products.
             Enables/disables the relaying of broadcast messages to 
             the wireless link."
            ::= { brzaccVLBridgeParameters 4 }

    brzaccVLUnicastRelaying OBJECT-TYPE
            SYNTAX  INTEGER  { disable(1), enable(2), na (255) }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU only. 
             Not applicable to BreezeNET-B products.
             Enables/disables the relaying of unicast messages to 
             the wireless link."
            ::= { brzaccVLBridgeParameters 5 }

    brzaccVLEthBroadcastFiltering OBJECT-TYPE
            SYNTAX  INTEGER { disable (1), 
                              onEthernetOnly (2), 
                              onWirelessOnly  (3),
                              onBothWirelessAndEthernet (4), 
                              na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only. 
             Enables/disables the filtering of Ethernet (layer2) 
             broadcasts.    
             disable             : No filtering.    
             onEthernetOnly      : Filters broadcasts received on the Ethernet port only.    
             onWirelessOnly      : Filters broadcasts received on the Wlan port only.    
             onBothWirelessAndEth: Filters broadcasts received on both ports."
            ::= { brzaccVLBridgeParameters 6 }                                                                        

brzaccVLEthBroadcastingParameters     OBJECT IDENTIFIER ::= {brzaccVLBridgeParameters 7}

    brzaccVLDHCPBroadcastOverrideFilter OBJECT-TYPE
            SYNTAX  INTEGER { disable (1), enable (2), na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only. 
             Enables or disables the broadcasting of DHCP messages, 
             overriding the general *brzaccVLEthBroadcastFiltering Ethernet 
             broadcast filtering option." 
            ::= { brzaccVLEthBroadcastingParameters 1 }

    brzaccVLPPPoEBroadcastOverrideFilter OBJECT-TYPE
            SYNTAX  INTEGER { disable (1), enable (2), na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only. 
             Enables or disables the broadcasting of PPPoE messages, 
             overriding the general *brzaccVLEthBroadcastFiltering Ethernet 
             broadcast filtering option."
            ::= { brzaccVLEthBroadcastingParameters 2 }

    brzaccVLARPBroadcastOverrideFilter OBJECT-TYPE
            SYNTAX  INTEGER { disable (1), enable (2), na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only. 
             Enables or disables the broadcasting of ARP messages, 
             overriding the general *brzaccVLEthBroadcastFiltering Ethernet 
             broadcast filtering option."
            ::= { brzaccVLEthBroadcastingParameters 3 }
            
    brzaccVLEthBroadcastMulticastLimiterOption OBJECT-TYPE
            SYNTAX  INTEGER { disable (1),
							  limitOnlyBroadcasts(2),
							  limitMulticastsExceptBroadcasts(3),
							  limitAllMulticasts(4) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
            Enable/disable the limiter for multicast and broadcast packets." 
            ::= { brzaccVLEthBroadcastingParameters 4 }
       
   brzaccVLEthBroadcastMulticastLimiterThreshold OBJECT-TYPE
            SYNTAX  INTEGER
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
            The limit on the number of multicast and broadcast packets when the 
            Ethernet Broadcast/Multicast Limiter Option is enabled.
            Range: 0 to 204800" 
            ::= { brzaccVLEthBroadcastingParameters 5 }
            
   brzaccVLEthBroadcastMulticastLimiterSendTrapInterval OBJECT-TYPE
            SYNTAX  INTEGER
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
            The minimum time between two successive traps that are sent indicating the 
            number of packets that were dropped by the Ethernet Broadcast/Multicast 
            Limiter since the last trap was sent.
            Range: 1 to 60 minutes" 
            ::= { brzaccVLEthBroadcastingParameters 6 }

brzaccVLToSPriorityParameters     OBJECT IDENTIFIER ::= {brzaccVLBridgeParameters 8}

    brzaccVLToSPrecedenceThreshold OBJECT-TYPE
            SYNTAX  INTEGER  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units. Not applicable to units with SW version 3.1 or higher.
             Priority threshold (based on the ToS) for frames received 
             from the Ethernet port.
             Range: 0 to 7."
            ::= { brzaccVLToSPriorityParameters 1 }

    brzaccVLRoamingOption OBJECT-TYPE
            SYNTAX  INTEGER  { disable (1), enable (2), na(255) }
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to SU/RB only.
             Disable/enable the roaming feature. When enabled, the SU/RB will start 
             scanning for an AU/BU after about one second of not receiving beacons or data 
             from current AU/BU. Once it found a new AU/BU, it will also send through 
             the wireless network a roaming SNAP on behalf of its clients informing 
             other devices in the network of their new location. When disabled, it 
             will wait for about seven seconds before starting scanning, and it will not 
             send a roaming SNAP."
            ::= { brzaccVLBridgeParameters 9 }

brzaccVLMacAddressDenyList  OBJECT IDENTIFIER ::= {brzaccVLBridgeParameters 10}

    brzaccVLMacAddressDenyListTable OBJECT-TYPE
            SYNTAX SEQUENCE OF BrzaccVLMacAddressDenyListEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to AU only. 
			 Not applicable to BreezeNET-B units.                                   
             A list of up to 100 MAC Addresses of SUs.
             If brzaccVLMacAddressDenyListAction is set to denyList, 
             these are SUs that are not allowed to transfer data 
             to the AU. 
             If brzaccVLMacAddressDenyListAction is set to allowList, 
             only these SUs are allowed to transfer data to the AU."
            ::= { brzaccVLMacAddressDenyList 1 }

    brzaccVLMacAddressDenyListEntry  OBJECT-TYPE
            SYNTAX BrzaccVLMacAddressDenyListEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to AU only.
			 Not applicable to BreezeNET-B units.                                   
             An entry in the Mac Address Deny List Table."
            INDEX { brzaccVLMacAddressDenyListTableIdx }
            ::= { brzaccVLMacAddressDenyListTable 1 }

    BrzaccVLMacAddressDenyListEntry ::= SEQUENCE {
            brzaccVLMacAddressDenyListTableIdx  INTEGER,
            brzaccVLMacAddressDenyListId  MacAddress
            }
        
    brzaccVLMacAddressDenyListTableIdx   OBJECT-TYPE
            SYNTAX  INTEGER (1..100) 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to AU only. 
			 Not applicable to BreezeNET-B units.                                   
             A read only table index for a MAC Address entry 
             in the Mac Address Deny List Table. Range: 1 to 100."
        ::= { brzaccVLMacAddressDenyListEntry 1 }

    brzaccVLMacAddressDenyListId   OBJECT-TYPE
            SYNTAX  MacAddress  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU only.
			 Not applicable to BreezeNET-B units.                                   
             The list of MAC Addresses in the Mac Address Deny
             List Table. 
             To Remove a MAC Address - SET the corresponding entry 
             to 0. 
             To Add a new MAC Address - SET an entry which is 
             currently 0."
        ::= { brzaccVLMacAddressDenyListEntry 2 }

    brzaccVLMacAddressDenyListAdd OBJECT-TYPE
            SYNTAX MacAddress
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU only. 
			 Not applicable to BreezeNET-B units.                                   
             Add a MAC address to the MAC Address Deny List Table"
            ::= { brzaccVLMacAddressDenyList 2 }

    brzaccVLMacAddressDenyListRemove OBJECT-TYPE
            SYNTAX MacAddress
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU only. 
			 Not applicable to BreezeNET-B units.                                   
             Delete a MAC address from the MAC Address Deny List Table"
            ::= { brzaccVLMacAddressDenyList 3 }

    brzaccVLNumberOfMacAddressesInDenyList OBJECT-TYPE
            SYNTAX INTEGER { na(255) }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to AU only. 
			 Not applicable to BreezeNET-B units.                                   
             Number of MAC addresses in the MAC Address Deny List Table."
            ::= { brzaccVLMacAddressDenyList 4 }

brzaccVLMacAddressDenyListAction OBJECT-TYPE
            SYNTAX  INTEGER  { denyList(1), allowedList(2), na(255) }
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to AU only.        
            Define the action to be used by the Mac Address Deny List.
            allowedList(2) means that the list becomes Allow list."
            ::= { brzaccVLMacAddressDenyList 5 }
            
            
brzAccVLPortsControl  OBJECT IDENTIFIER ::= {brzaccVLBridgeParameters 11}

    brzaccVLEthernetPortControl OBJECT-TYPE
            SYNTAX  INTEGER   { disable(1), enable(2), na(255) }  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             Enable/disable the Ethernet port. When disabled, only 
             data frames are blocked. Management frames are accepted."
            ::= { brzAccVLPortsControl 1 }


-- Air Interface Params
-- =====================
brzaccVLAirInterface      OBJECT IDENTIFIER ::= {breezeAccessVLMib 6}

brzaccVLESSIDParameters      OBJECT IDENTIFIER ::= {brzaccVLAirInterface 1}

    brzaccVLESSID OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..31))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units. 
             The Extended Service Set ID (ESSID) used to prevent 
             the merging of collocated systems.
             The ESSID is accessible only with the write community 
             string (administrator password).
             Up to 31 printable case sensitive ASCII characters." 
            ::= { brzaccVLESSIDParameters 1 }


    brzaccVLOperatorESSIDOption  OBJECT-TYPE
            SYNTAX INTEGER {disable (1) , enable (2), na (255) }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU only. 
             Enabling/disabling the use of the Operator ESSID."
            ::= { brzaccVLESSIDParameters 2 }


    brzaccVLOperatorESSID OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..31))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU only.
             A secondary ESSID to support easy installation of SUs as well as
             the use of the Best AU/BU feature.
             Accessible only with SNMP Write Community 
             Up to 31 printable case sensitive ASCII characters." 
            ::= { brzaccVLESSIDParameters 3}

	brzaccVLRunTimeESSID OBJECT-TYPE
		    SYNTAX DisplayString (SIZE(31))
		    MAX-ACCESS read-only
		    STATUS current
		    DESCRIPTION  
		    "Applicable to SU/RB only. 
		     The ESSID of the associated AU/BU.
		     Accessible only with SNMP Write Community.
		     Up to 31 printable ASCII characters, case sensitive."
		    ::= { brzaccVLESSIDParameters 4 }


    brzaccVLMaximumCellRadius  OBJECT-TYPE
            SYNTAX  INTEGER  
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to all units.  
             For AU/BU: read-write. In units with SW version 2.0 and up -
             applicable only when the Cell Distance Mode is set to Manual. 
             The highest distance from the AU/BU of any SU/RB served by it. 
             Affects the maximum time the units wait for a response message 
             and the slot size by taking into account the round trip propagation delay. 
             For SU/RB: read-only. The distance is learned from the AU/BU. 
             Range: For units below version 2.0 the range is 0 - 50000 Meters. 
             Otherwise - the range is 0 to 54 Kilometers.
             0 means no compensation (minimum slot size, maximal delay timeout)."
            ::= { brzaccVLAirInterface 2 }

    brzaccVLAIFS  OBJECT-TYPE
            SYNTAX  INTEGER { oneSlot (1), twoSlots (2) } 
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to AU and SU. Not applicable to BreezeNET-B products.
             Not applicable if Wireless Link Prioritization is enabled.
             Arbitration Inter-Frame Spacing (AIFS) value, in slots. 
             This is the number of time slots that define the DIFS. (DIFS=SIFS+AIFS). 
             A value of 1 should be used only in point-to-point applications to 
             allow one unit to have advantage over the other unit."
            ::= { brzaccVLAirInterface 3 }


	brzaccVLWirelessTrapThreshold OBJECT-TYPE
	    SYNTAX INTEGER     
	    MAX-ACCESS read-write
	    STATUS current
	    DESCRIPTION
	    "Applicable to AU/BU only.
	     A wireless link quality threshold, expressed in % of retransmissions,
	     for sending the brzaccVLAUWirelessQualityTRAP.   
	     This trap indicate whether the quality has gone below or 
	     above the specified threshold.
	     The Threshold Range: 1 to 100 (%  retransmissions)."
	     ::= {  brzaccVLAirInterface 4 }



    brzaccVLTransmitPowerTable OBJECT-TYPE
            SYNTAX SEQUENCE OF BrzaccVLTransmitPowerEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to all units.
             A table of transmit power parameters. " 
            ::= { brzaccVLAirInterface 5}

    brzaccVLTransmitPowerEntry  OBJECT-TYPE
            SYNTAX BrzaccVLTransmitPowerEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to all units. 
             An entry in the Transmit Power Table." 
            INDEX { brzaccVLTransmitPowerIdx }
            ::= { brzaccVLTransmitPowerTable 1 }
                                
    BrzaccVLTransmitPowerEntry ::= SEQUENCE {   brzaccVLTransmitPowerIdx          INTEGER,
                                				brzaccVLApplicableModulationLevel INTEGER,
                                				brzaccVLMaximumTxPowerRange       DisplayString,
                                				brzaccVLTxPower     	          DisplayString,
												brzaccVLCurrentTxPower		      DisplayString
                                			  }

    brzaccVLTransmitPowerIdx OBJECT-TYPE
            SYNTAX INTEGER	(1..4)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             An index of an entry in the Transmit Power Table." 
            ::= { brzaccVLTransmitPowerEntry 1 }
								

    brzaccVLApplicableModulationLevel       OBJECT-TYPE
            SYNTAX INTEGER {level1to5 (1), level6  (2), level7  (3),level8  (4)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             The applicable modulation level for an entry in the Transmit Power Table.
              Level 8 is not applicable to units with HW revision A." 
            ::= { brzaccVLTransmitPowerEntry 2 }

    brzaccVLMaximumTxPowerRange  OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             The allowed range for the brzaccVLTxPower parameter at the 
             applicable modulation level . Range: -10 to the maximum allowed 
             power level at the applicable modulation level , in dBm." 
            ::= { brzaccVLTransmitPowerEntry 3 }


    brzaccVLTxPower OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             Read-only for units with SW version 4.0 and higher.
			 In AU/BU: The transmit power in dBm defined for the applicable rate.
			 In SU/RB: If ATPC is disabled, this is the transmit power in dBm 
			 defined for the applicable rate.
			 If ATPC is enabled, it serves as the initial transmit power in dBm 
			 for the ATPC algorithm. 
			 In SU/RB: The range is -10 dBm to the power value defined by 
			           brzaccVLMaximumTxPower for the applicable modulation level.
			 In AU/BU: The range is -10 dBm to the power value defined by 
			           brzaccVLMaximumTxPowerRange for the applicable modulation level."
            ::= { brzaccVLTransmitPowerEntry 4 }



    brzaccVLCurrentTxPower OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB.
             The actual transmit power in dBm for the applicable rate.
             Range: -17 to the maximum value defined by brzaccVLMaximumTxPowerRange 
             for the applicable modulation level."
            ::= { brzaccVLTransmitPowerEntry 5 }

    brzaccVLMaximumTransmitPowerTable OBJECT-TYPE
            SYNTAX SEQUENCE OF BrzaccVLMaximumTransmitPowerEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to SU/RB only.
             A table of maximum transmit power parameters. " 
            ::= { brzaccVLAirInterface 6}

    brzaccVLMaximumTransmitPowerEntry  OBJECT-TYPE
            SYNTAX BrzaccVLMaximumTransmitPowerEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to SU/RB only. 
             An entry in the Maximum Transmit Power Table." 
            INDEX { brzaccVLMaximumTransmitPowerIdx }
            ::= { brzaccVLMaximumTransmitPowerTable 1 }
                                
    BrzaccVLMaximumTransmitPowerEntry ::= SEQUENCE {   brzaccVLMaximumTransmitPowerIdx        INTEGER,
                                				       brzaccVLMaxTxApplicableModulationLevel INTEGER,
                                				       brzaccVLDefinedMaximumTxPowerRange     DisplayString,
                                				       brzaccVLMaxTxPower     	              DisplayString
                                			  }

    brzaccVLMaximumTransmitPowerIdx OBJECT-TYPE
            SYNTAX INTEGER	(1..4)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             An index of an entry in the Maximum Transmit Power Table." 
            ::= { brzaccVLMaximumTransmitPowerEntry 1 }
								

    brzaccVLMaxTxApplicableModulationLevel       OBJECT-TYPE
            SYNTAX INTEGER {level1to5 (1), level6  (2), level7  (3),level8  (4)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             The applicable modulation level for an entry in the Maximum 
              Transmit Power Table.
              Level 8 is not applicable to units with HW revision A." 
            ::= { brzaccVLMaximumTransmitPowerEntry 2 }

    brzaccVLDefinedMaximumTxPowerRange  OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             The allowed range for the brzaccVLMaxTxPower parameter at the 
             applicable modulation level .
             Range: -10 to the maximum allowed power level at the applicable 
             modulation level , in dBm." 
            ::= { brzaccVLMaximumTransmitPowerEntry 3 }


    brzaccVLMaxTxPower OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
            Read-only for units with SW version 4.0 and higher.
			The maximum value that can be configured for the brzaccVLTxPower 
			parameter. This is also the maximum power level that can be reached 
			by the ATPC algorithm.
			The range is -10 dBm to the maximum value defined by 
			brzaccVLDefinedMaximumTxPowerRange for the applicable modulation level."
            ::= { brzaccVLMaximumTransmitPowerEntry 4 }

    brzaccVLMaxNumOfAssociations OBJECT-TYPE
            SYNTAX  INTEGER  
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to AU only. 
             Not applicable to BreezeNET-B products.
             Sets the upper limit for the number of SUs 
             that can be associated with the AU.
             Range: For regular AUs (AU-BS, AU-SA) 
             the range is from 0 to 512 if encryption is disabled
             the range id form 0 to 124 if encryption is enabled
             For AUS-BS and AUS-SA with SW version 4.0 and higher 
             the range is between 0 to 8 or 25 (via licensing).
             For AUS-BS and AUS-SA with SW version below 4.0 the range 
             is between 0 to 5.  
             BreezeNET-B products return 65535."
            ::= { brzaccVLAirInterface 10 }


brzaccVLBestAu   OBJECT IDENTIFIER ::= {brzaccVLAirInterface 11}

    brzaccVLBestAuSupport OBJECT-TYPE
            SYNTAX  INTEGER  { disable (1), enable (2), na (255) }
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to SU/RB only. 
             Disable/enable the Best AU/BU selection mechanism."
            ::= { brzaccVLBestAu  1 }

    brzaccVLBestAuNoOfScanningAttempts OBJECT-TYPE
            SYNTAX  INTEGER
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to SU/RB only. 
             The number of scanning attempts to collect information 
             for the Best AU/BU decision.
             Range: 1 to 255."
            ::= { brzaccVLBestAu  2 }

    brzaccVLPreferredAuMacAddress OBJECT-TYPE
            SYNTAX MacAddress 
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to SU/RB only.
             The MAC address of the preferred AU/BU (overriding the 
             Best AU/BU selection process). 
             000000000000 means no preferred AU/BU."
            ::= { brzaccVLBestAu 3 }

    brzaccVLNeighborAuTable OBJECT-TYPE
            SYNTAX SEQUENCE OF BrzaccVLNeighborAuEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to SU/RB only. 
             A table of data on neighboring AUs/BUs."
            ::= { brzaccVLBestAu 4}

    brzaccVLNeighborAuEntry  OBJECT-TYPE
            SYNTAX BrzaccVLNeighborAuEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to SU/RB only. 
             An entry in the Neighbor AU/BU Table." 
            INDEX { brzaccVLNeighborAuIdx }
            ::= { brzaccVLNeighborAuTable 1 }
                                
    BrzaccVLNeighborAuEntry ::= SEQUENCE { brzaccVLNeighborAuIdx        INTEGER,
    							brzaccVLNeighborAuMacAdd                MacAddress,
                                brzaccVLNeighborAuESSID                 DisplayString,
                                brzaccVLNeighborAuSNR                   INTEGER,
                                brzaccVLNeighborAuAssocLoadStatus       INTEGER,
                                brzaccVLNeighborAuMark                  INTEGER,
	                            brzaccVLNeighborAuHwRevision	        INTEGER,
	                            brzaccVLNeighborAuCountryCode           INTEGER,
	                            brzaccVLNeighborAuSwVer			        DisplayString,
	                            brzaccVLNeighborAuAtpcOption	        INTEGER,
	                            brzaccVLNeighborAuAdapModOption	        INTEGER,
	                            brzaccVLNeighborAuBurstModeOption       INTEGER,
	                         	brzaccVLNeighborAuDfsOption	            INTEGER,
	                            brzaccVLNeighborAuConcatenationOption   INTEGER,
	                            brzaccVLNeighborAuLearnCountryCodeBySU  INTEGER,
	                            brzaccVLNeighborAuSecurityMode	        INTEGER,
	                            brzaccVLNeighborAuAuthOption	        INTEGER,
	                            brzaccVLNeighborAuDataEncyptOption      INTEGER,
	                            brzaccVLNeighborAuPerSuDistanceLearning INTEGER
                                }

    brzaccVLNeighborAuIdx OBJECT-TYPE
            SYNTAX INTEGER	(1..20)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only. 
             An index of an entry in the Neighbor AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 1 }
								
    brzaccVLNeighborAuMacAdd OBJECT-TYPE
            SYNTAX MacAddress
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only. 
             A MAC address of an AU/BU in the Neighbor AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 2 }

    brzaccVLNeighborAuESSID OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.  
             The ESSID of an AU/BU in the Neighbor AU/BU Table.
             Accessible only with SNMP Write Community."
            ::= { brzaccVLNeighborAuEntry 3 }

    brzaccVLNeighborAuSNR OBJECT-TYPE
            SYNTAX INTEGER { na (255) }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only. 
             The received signal quality (SNR) in dB of an AU/BU 
             in the Neighbor AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 4 }

    brzaccVLNeighborAuAssocLoadStatus OBJECT-TYPE
            SYNTAX INTEGER {  full (1),notFull (2), na (255) }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only. 
             Neighbor AU/BU association load status in the Neighbor 
             AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 5 }
    
    brzaccVLNeighborAuMark OBJECT-TYPE
            SYNTAX INTEGER
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             Neighbor AU/BU mark in the Neighbor AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 6 }

    brzaccVLNeighborAuHwRevision OBJECT-TYPE
            SYNTAX INTEGER {hwRevisionA (1), hwRevisionB (2), hwRevisionC (3),
							hwRevisionD (4), hwRevisionE (5),na (255)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             Neighbor AU/BU HW revision in the Neighbor AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 7 }

    brzaccVLNeighborAuCountryCode OBJECT-TYPE
            SYNTAX INTEGER 	
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             Neighbor AU/BU supported country code in the Neighbor 
             AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 8 }

    brzaccVLNeighborAuSwVer OBJECT-TYPE
            SYNTAX DisplayString 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             Neighbor AU/BU SW version in the Neighbor 
             AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 9 }

    brzaccVLNeighborAuAtpcOption OBJECT-TYPE
            SYNTAX INTEGER { disable (1), enable (2), na (255)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             Neighbor AU/BU ATPC option configuration in the Neighbor 
             AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 10 }

    brzaccVLNeighborAuAdapModOption OBJECT-TYPE
            SYNTAX INTEGER { disable (1), enable (2), na (255)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             Neighbor AU/BU adaptive modulation option configuration 
             in the Neighbor AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 11 }

    brzaccVLNeighborAuBurstModeOption OBJECT-TYPE
            SYNTAX INTEGER { disable (1), enable (2), na (255)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             Neighbor AU/BU burst mode option configuration 
             in the Neighbor AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 12 }

    brzaccVLNeighborAuDfsOption OBJECT-TYPE
            SYNTAX INTEGER { disable (1), enable (2), na(255)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             Neighbor AU/BU DFS option configuration 
             in the Neighbor AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 14 }

    brzaccVLNeighborAuConcatenationOption OBJECT-TYPE
            SYNTAX INTEGER { disable (1), enable (2), na (255)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             Neighbor AU/BU concatenation option configuration 
             in the Neighbor AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 15 }

    brzaccVLNeighborAuLearnCountryCodeBySU OBJECT-TYPE
            SYNTAX INTEGER { disable (1), enable (2), na (255)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU only.
             Starting with 4.0 is not applicable for BA4900 and BreezeNET B products.
             Neighbor AU Learn Country Code by SU configuration 
             in the Neighbor AU Table."
            ::= { brzaccVLNeighborAuEntry 17 }

   brzaccVLNeighborAuSecurityMode     OBJECT-TYPE
            SYNTAX INTEGER  {wep(1), aesOCB(2), fips197(3), na (255)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             Neighbor AU/BU security mode configuration 
             in the Neighbor AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 18 }

   brzaccVLNeighborAuAuthOption     OBJECT-TYPE
            SYNTAX INTEGER  {openSystem (1), sharedKey (2), na (255)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             Neighbor AU/BU authentication option configuration 
             in the Neighbor AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 19 }

   brzaccVLNeighborAuDataEncyptOption     OBJECT-TYPE
            SYNTAX INTEGER  {disable (1), enable (2), na (255)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
             Neighbor AU/BU data encryption option configuration 
             in the Neighbor AU/BU Table."
            ::= { brzaccVLNeighborAuEntry 20 }
            
	brzaccVLNeighborAuPerSuDistanceLearning		OBJECT-TYPE
            SYNTAX INTEGER  {disable (1), enable (2), na (255)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU only.
             Neighbor AU per SU distance learning option configuration 
             in the Neighbor AU Table."
            ::= { brzaccVLNeighborAuEntry 21 }

brzaccVLFrequencyDefinition	   OBJECT IDENTIFIER ::= {brzaccVLAirInterface 12}
   

    brzaccVLSubBandLowerFrequency OBJECT-TYPE
            SYNTAX INTEGER
            MAX-ACCESS read-write
            STATUS obsolete
            DESCRIPTION  
		    "Applicable to SU only. 
		     Not applicable to units with SW version 2.0 or higher. 
             The lowest frequency in the subset to be used for scanning.
             For 5.8GHz products the range is 5740 to 5830 MHz using 10MHz resolution.
             For 4.9GHz products the range is 4920 to 5080 MHz using 10MHz resolution.
             For HW Revision C and above this leaf is not relevant - shall return 0."
            ::= { brzaccVLFrequencyDefinition 1 }

    brzaccVLSubBandUpperFrequency OBJECT-TYPE
            SYNTAX INTEGER
            MAX-ACCESS read-write
            STATUS obsolete
            DESCRIPTION  
            "Applicable to SU only. 
             Not applicable to units with SW version 2.0 or higher. 
             The highest frequency in the subset to be used for scanning.
             For 5.8GHz products the range is 5740 to 5830 MHz using 10MHz resolution.
             For 4.9GHz products the range is 4920 to 5080 MHz using 10MHz resolution.
             For HW Revision C and above this leaf is not relevant - shall return 0."
            ::= { brzaccVLFrequencyDefinition 2 }

    brzaccVLScanningStep  OBJECT-TYPE
            SYNTAX INTEGER	{ mhz-5(1), mhz-10(2) , mhz-20(3), na(255) }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units - For flexible Sub-Bands only.		
             For units with version 2.0 and above this is a read-only parameter.
             The scanning step to be used for generating the frequency subset."
            ::= { brzaccVLFrequencyDefinition 3 }


    brzaccVLFrequencySubsetTable OBJECT-TYPE
            SYNTAX SEQUENCE OF BrzaccVLFrequencySubsetEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to SU/RB and to AU/BU.
             Not applicable to SU/RB with SW version 4.0 and higher.
			 The Frequency Subset Table that includes all frequencies from 
			 the selected Sub-band."
            ::= { brzaccVLFrequencyDefinition 4 }

    brzaccVLFrequencySubsetEntry  OBJECT-TYPE
            SYNTAX BrzaccVLFrequencySubsetEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to SU/RB and to AU/BU.
             Not applicable to SU/RB with SW version 4.0 and higher.
             An entry in the Frequency Subset Table. "  
             INDEX { brzaccVLFrequencySubsetTableIdx }
            ::= { brzaccVLFrequencySubsetTable 1 }

    BrzaccVLFrequencySubsetEntry ::= SEQUENCE {
            brzaccVLFrequencySubsetTableIdx       INTEGER,
            brzaccVLFrequencySubsetFrequency      INTEGER,
            brzaccVLFrequencySubsetActive         INTEGER,
            brzaccVLFrequencySubsetFrequencyNew   DisplayString
            }
               
    brzaccVLFrequencySubsetTableIdx   OBJECT-TYPE
            SYNTAX INTEGER  (1..40)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB and to AU/BU.
             Not applicable to SU/RB with SW version 4.0 and higher.
			 An index of an entry in the Frequency subset Table."
           ::= { brzaccVLFrequencySubsetEntry 1 }


    brzaccVLFrequencySubsetFrequency   OBJECT-TYPE
            SYNTAX INTEGER  
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB and to AU/BU. 
             Not applicable to SU/RB with SW version 4.0 and higher.
             Applicable to all units with HW revision B and lower 
             (for units with HW revision C and higher replaced by 
             brzaccVLFrequencySubsetFrequencyNew to support a 
             resolution of 0.5 MHz).  
             The frequency in MHz of an entry in the Frequency Subset table."
           ::= { brzaccVLFrequencySubsetEntry 2 }

    brzaccVLFrequencySubsetActive   OBJECT-TYPE
            SYNTAX INTEGER  {active (1) , notActive (2)}
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB and to AU/BU.
             Not applicable to SU/RB with SW version 4.0 and higher.
			 The status of an entry in the Frequency subset Table.
			 The frequency of an active entry will be included in the 
			 final list of frequencies to be used for scanning."
           ::= { brzaccVLFrequencySubsetEntry 3 }

    brzaccVLFrequencySubsetFrequencyNew   OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to all units. 
             Not applicable to SU/RB with SW version 4.0 and higher.
             The frequency in MHz of an entry in the Frequency Subset table. 
             (Replaces brzaccVLFrequencySubsetFrequency to support a resolution 
             of 0.5 MHz for units with HW revision C and higher)."
           ::= { brzaccVLFrequencySubsetEntry 4 }

    brzaccVLSetSelectedFreqSubset  OBJECT-TYPE
            SYNTAX INTEGER	 {setSelectedFreqsSubset(1) ,cancel (2)}
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB and to AU/BU.
             Not applicable to SU/RB with SW version 4.0 and higher.
			 Apply the selected subset.
			 After the next reset the new subset will be used."
            ::= { brzaccVLFrequencyDefinition 5 }




    brzaccVLCurrentFrequencySubsetTable OBJECT-TYPE
            SYNTAX SEQUENCE OF BrzaccVLCurrentFrequencySubsetEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to SU/RB and to AU/BU.
             Not applicable to SU/RB with SW version 4.0 and higher.
			 The Current Frequency Subset table. In SU/RB it includes all 
			 frequencies that are currently used for scanning.
			 In AU/BU it includes all frequencies that can be used by the 
			 DFS mechanism (if applicable)"
                ::= { brzaccVLFrequencyDefinition 6 }

    brzaccVLCurrentFrequencySubsetEntry  OBJECT-TYPE
            SYNTAX BrzaccVLCurrentFrequencySubsetEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to SU/RB and to AU/BU.
             An entry in the Current Frequency Subset Table. "  
             INDEX { brzaccVLCurrentFrequencySubsetTableIdx }
            ::= { brzaccVLCurrentFrequencySubsetTable 1 }

    BrzaccVLCurrentFrequencySubsetEntry ::= SEQUENCE {
            brzaccVLCurrentFrequencySubsetTableIdx      INTEGER,
            brzaccVLCurrentFrequencySubsetFrequency     INTEGER,
            brzaccVLCurrentFrequencySubsetFrequencyNew  DisplayString
            }
               
    brzaccVLCurrentFrequencySubsetTableIdx   OBJECT-TYPE
            SYNTAX INTEGER  (1..40)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB and to AU/BU.
			 An index of an entry in the Current Frequency subset Table.
			 Not applicable to SU/RB with SW version 4.0 and higher."
           ::= { brzaccVLCurrentFrequencySubsetEntry 1 }


    brzaccVLCurrentFrequencySubsetFrequency   OBJECT-TYPE
            SYNTAX INTEGER  
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
			"Applicable to all units. 
			 Not applicable to SU/RB with SW version 4.0 and higher.
			 Applicable to all units with HW revision B and lower 
			 (for units with HW revision C and higher replaced by 
			 brzaccVLCurrentFrequencySubsetFrequencyNew to support 
			 a resolution of 0.5 MHz). 
			 The frequency in MHz of an entry in the Current Frequency Subset table."
           ::= { brzaccVLCurrentFrequencySubsetEntry 2 }

    brzaccVLCurrentFrequencySubsetFrequencyNew   OBJECT-TYPE
            SYNTAX DisplayString  
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to all units. Not applicable to SU/RB with SW version 4.0 and higher. 
             The frequency in MHz of an entry in the Current Frequency Subset table. 
             (Replaces brzaccVLCurrentFrequencySubsetFrequency to support a 
             resolution of 0.5 MHz for units with HW revision C and higher)."
            ::= { brzaccVLCurrentFrequencySubsetEntry 3 }
	
    brzaccVLCurrentAUOperatingFrequency  OBJECT-TYPE
            SYNTAX INTEGER	
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
		    "Applicable to AU/BU with HW revision B and lower 
		     (for units with HW revision C and higher replaced by 
		     brzaccVLCurrentUOperatingFrequencyNew to support a resolution 
		     of 0.5 MHz). 
		     The operating frequency in MHz. 
		     For 5.8GHz products with SW version below 2.0 the range is 
		     5740 to 5830 MHz using 10MHz resolution. 
		     For units with SW version 2.0 and up the range is as defined 
		     in the selected Sub Band."
            ::= { brzaccVLFrequencyDefinition 7 }

    brzaccVLCurrentAUOperatingFrequencyNew  OBJECT-TYPE
            SYNTAX DisplayString	
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU. The operating frequency in MHz. 
             (Replaces brzaccVLCurrentAUOperatingFrequency to support 
             a resolution of 0.5 MHz for units with HW revision C and higher). 
             For 5.8GHz products with SW version below 2.0 the range is 
             5740 to 5830 MHz using 10MHz resolution. 
             For units with SW version 2.0 and up the range is as defined 
             in the selected Sub Band."
            ::= { brzaccVLFrequencyDefinition 13 }

    brzaccVLAUDefinedFrequency  OBJECT-TYPE
            SYNTAX INTEGER	
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU with HW revision B and lower 
             (for units with HW revision C and higher replaced by 
             brzaccVLAUDefinedFrequencyNew to support a resolution of 0.5 MHz). 
             For 5.8GHz products with SW version below 2.0 this is the frequency 
             in MHz of the AU/BU after the next reset. 
             For units with SW version 2.0 and up this is the frequency in MHz 
             to use when the DFS Option is disabled. 
             For 5.8GHz products with SW version below 2.0 the range is 
             5740 to 5830 MHz using 10MHz resolution. 
             For units with SW version 2.0 and up the range is as defined 
             in the selected Sub Band."            
            ::= { brzaccVLFrequencyDefinition 8 }

    brzaccVLAUDefinedFrequencyNew  OBJECT-TYPE
            SYNTAX DisplayString	
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU. 
             For 5.8GHz products with SW version below 2.0 this is the 
             frequency in MHz of the AU/BU after the next reset. 
             For units with SW version 2.0 and up this is the 
             frequency in MHz to use when the DFS Option is disabled. 
             (Replaces brzaccVLAUDefinedFrequency to support a resolution 
             of 0.5 MHz for units with HW revision C and higher). 
             For 5.8GHz products with SW version below 2.0 the range 
             is 5740 to 5830 MHz using 10MHz resolution. 
             For units with SW version 2.0 and up the range is as 
             defined in the selected Sub Band."
            ::= { brzaccVLFrequencyDefinition 14 }

    brzaccVLCurrentSUOperatingFrequency  OBJECT-TYPE
            SYNTAX DisplayString	
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
			 The frequency used currently by the unit.
			 For 5.8GHz products with SW version below 2.0 the range is 
			 5740 to 5830 MHz using 10MHz resolution.
             For units with SW version 2.0 and up the range is as defined 
             in the selected Sub Band."
            ::= { brzaccVLFrequencyDefinition 9 }

brzaccVLSubBandSelect   OBJECT IDENTIFIER ::= {brzaccVLFrequencyDefinition 10}


    brzaccVLSelectSubBandIndex OBJECT-TYPE
            SYNTAX INTEGER	
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
            "Applicable to all units with SW version below 4.0 
            For units with SW version 4.0 and up it is applicable 
            only for AU/BU. For SU/RB it defines only the sub-band 
            for the Spectrum Analyzer.
             The ID of the sub-band used by the unit."  
            ::= { brzaccVLSubBandSelect 1 }



brzaccVLDFSParameters   OBJECT IDENTIFIER ::= {brzaccVLFrequencyDefinition 11}

    brzaccVLDFSOption  OBJECT-TYPE
            SYNTAX INTEGER	{ disable (1) , enable (2), na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU only.
             Enabling/disabling the DFS Algorithm. 
             Not applicable if DFS Option is not supported by the current Sub Band."
            ::= { brzaccVLDFSParameters 1 }

    brzaccVLDFSChannelCheckTime  OBJECT-TYPE
            SYNTAX INTEGER	 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU only. 
             Defines the time the unit checks the channel for presence of 
             radar signals and does not transmit after power up or association 
             or after moving to a new channel due to detecting radar in the used 
             channel. Range: 1 to 3600 (seconds)."
            ::= { brzaccVLDFSParameters 3 }


    brzaccVLDFSChannelAvoidancePeriod  OBJECT-TYPE
            SYNTAX INTEGER	 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU only. 
             Defines the time after detecting radar signals in a channel of 
             avoiding using the channel or adjacent channels in 
             accordance with the bandwidth. Range: 1 to 60 (minutes)."
            ::= { brzaccVLDFSParameters 4 }


    brzaccVLDFSSuWaitingOption  OBJECT-TYPE
            SYNTAX INTEGER	{ disable (1) , enable (2), na(255) }	 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU only. 
            Defines whether the associated SUs should wait for this AU/BU 
            after it stopped transmitting due to radar detection, before 
            they starts scanning for other AUs/BUs."
            ::= { brzaccVLDFSParameters 5 }


    brzaccVLDFSClearRadarDetectedChannelsAfterReset OBJECT-TYPE
            SYNTAX  INTEGER { cancel (1), clearRadarChannels (2), na(255) }  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU only. 
             Clear Radar Detected and Adjacent to Radar channels after unit reset.
             Returns the unit to operate in default frequency."
            ::= { brzaccVLDFSParameters 6 }

	brzaccVLDFSRadarDetectionChannelsTable OBJECT-TYPE	  
			SYNTAX SEQUENCE OF BrzaccVLDFSRadarDetectionChannelsEntry
			MAX-ACCESS not-accessible
			STATUS current
			DESCRIPTION
            "Applicable to AU/BU only. 
             Applicable only when DFS option is on.
             Displays the current channels defined in the sub-band and their radar 
             detection status."
			::= { brzaccVLDFSParameters 7 }

	brzaccVLDFSRadarDetectionChannelsEntry OBJECT-TYPE	
			SYNTAX BrzaccVLDFSRadarDetectionChannelsEntry
			MAX-ACCESS not-accessible
			STATUS current
	        DESCRIPTION
	        "Applicable to AU/BU only. 
	         An entry in the brzaccVLDFSRadarDetectionChannelsTable."
			INDEX { brzaccVLDFSChannelIdx }
			::= { brzaccVLDFSRadarDetectionChannelsTable 1 }
								
	BrzaccVLDFSRadarDetectionChannelsEntry ::= SEQUENCE { 
	        brzaccVLDFSChannelIdx	                    INTEGER, 
			brzaccVLDFSChannelFrequency                 INTEGER,	 
			brzaccVLDFSChannelRadarStatus               INTEGER,
			brzaccVLDFSChannelFrequencyNew              DisplayString }

	brzaccVLDFSChannelIdx   OBJECT-TYPE			 
			SYNTAX INTEGER  (1..40)
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION	 
            "Applicable to AU/BU only. Read-only. 
             The index of the entry in the 
             brzaccVLDFSRadarDetectionChannelsTable."
	    ::= { brzaccVLDFSRadarDetectionChannelsEntry 1 }
		   							
	brzaccVLDFSChannelFrequency   OBJECT-TYPE			 
			SYNTAX INTEGER  
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION	 
			"Applicable to AU/BU with HW revision B and lower 
			 (for units with HW revision C and higher replaced by 
			 brzaccVLDFSChannelFrequency New to support a resolution 
			 of 0.5 MHz). 
			 The frequency in MHz of a channel in the DFS Radar 
			 Detection Channels Table."
	    ::= { brzaccVLDFSRadarDetectionChannelsEntry 2 }

    brzaccVLDFSChannelRadarStatus   OBJECT-TYPE			 
			SYNTAX INTEGER  { radarFree       (1),
			                  adjacentToRadar (2),
			                  radarDetected   (3) }
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION	 
            "Applicable to AU/BU only.  
             The radar detection status of a channel in 
             brzaccVLDFSRadarDetectionChannelTable."
	    ::= { brzaccVLDFSRadarDetectionChannelsEntry 3 }

	brzaccVLDFSChannelFrequencyNew   OBJECT-TYPE			 
			SYNTAX DisplayString  
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION	 
			"Applicable to AU/BU. The frequency of a channel in the 
			 DFS Radar Detection Channels Table. 
			 (Replaces brzaccVLDFSChannelFrequency to support a 
			 resolution of 0.5 MHz for units with HW revision C and higher)."
	    ::= { brzaccVLDFSRadarDetectionChannelsEntry 4 }

    brzaccVLDFSMinimumPulsesToDetect  OBJECT-TYPE
            SYNTAX INTEGER	 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU only. 
             Defines the minimum number of pulses to detect a radar. 
             Range: 1 - 100."
            ::= { brzaccVLDFSParameters 8 }


brzaccVLDFSChannelReuseParameters OBJECT IDENTIFIER ::= {brzaccVLDFSParameters 9}

    brzaccVLDFSChannelReuseOption  OBJECT-TYPE
            SYNTAX INTEGER	{ disable (1) , enable (2), na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU only.
             Enabling/disabling the DFS Channel Reuse Algorithm. 
             Not applicable if DFS Option is not supported by the current Sub Band."
            ::= { brzaccVLDFSChannelReuseParameters 1 }

    brzaccVLDFSRadarActivityAssessmentPeriod  OBJECT-TYPE
            SYNTAX INTEGER	 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU only. 
             Range: 1 to 12 (Houres)."
            ::= { brzaccVLDFSChannelReuseParameters 2 }

    brzaccVLDFSMaximumNumberOfDetectionsInAssessmentPeriod  OBJECT-TYPE
            SYNTAX INTEGER	 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU only. 
             Range: 1 to 10 (Times)."
            ::= { brzaccVLDFSChannelReuseParameters 3 }

   brzaccVLCountryCodeLearningBySU OBJECT-TYPE
            SYNTAX  INTEGER  { disable(1), enable(2), na(255) }
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to AU only. 
             Starting with 4.0 it is nor applicable for BA4900 and BreezeNET B.
             Defines whether the SUs learn the country code of the AU."
            ::= { brzaccVLFrequencyDefinition 12 }


-- AUTOMATIC SUB BAND SELECT BEGIN

	brzaccVLAutoSubBandSelect	OBJECT IDENTIFIER ::= { brzaccVLFrequencyDefinition 15 }
	
	brzaccVLAutoSubBandSelectedFreqSubset  OBJECT-TYPE
            SYNTAX INTEGER	 { setAllSelectedFreqsSubset(1), cancel (2) }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB with SW version 4.0 and higher.        
			 Apply the selected subset. After the next reset the new 
			 subset will be used for scanning."
            ::= { brzaccVLAutoSubBandSelect 1 }
            
	brzaccVLAutoSubBandFrequencySubsetTable OBJECT-TYPE
            SYNTAX SEQUENCE OF BrzaccVLAutoSubBandFrequencySubsetEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to SU/RB with SW version 4.0 and higher. 
            The Frequency Subset Table that includes all available 
            sub-bands and all the frequencies in these sub-bands."
            ::= { brzaccVLAutoSubBandSelect 2 }

    brzaccVLAutoSubBandFrequencySubsetEntry  OBJECT-TYPE
            SYNTAX BrzaccVLAutoSubBandFrequencySubsetEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to SU/RB with SW version 4.0 and higher.
             An entry in the Frequency Subset Table. "  
             INDEX { brzaccVLAutoSubBandFrequencySubsetBandIdx, brzaccVLAutoSubBandFrequencySubsetFrequencyIdx }
            ::= { brzaccVLAutoSubBandFrequencySubsetTable 1 }

    BrzaccVLAutoSubBandFrequencySubsetEntry ::= SEQUENCE {
            brzaccVLAutoSubBandFrequencySubsetBandIdx		INTEGER,
            brzaccVLAutoSubBandFrequencySubsetFrequencyIdx  INTEGER,
            brzaccVLAutoSubBandFrequencySubsetActive        INTEGER,
            brzaccVLAutoSubBandFrequencySubsetFrequency     DisplayString
            }
               
    brzaccVLAutoSubBandFrequencySubsetBandIdx   OBJECT-TYPE
            SYNTAX INTEGER  (1..5)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB with SW version 4.0 and higher.
			 The index of the applicable Sub Band. 
			 This is the Sub Band ID of the relevant entry in 
			 the Country Dependent Parameters table.
			 Serves also as an index of the entry in the 
			 Frequency subset Table."
           ::= { brzaccVLAutoSubBandFrequencySubsetEntry 1 }
           
	brzaccVLAutoSubBandFrequencySubsetFrequencyIdx   OBJECT-TYPE
            SYNTAX INTEGER  (1..40)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB with SW version 4.0 and higher.
			 The index of the applicable frequency in the 
			 applicable Sub Band.  
			 Serves also as an index of the entry in the 
			 Frequency subset Table."
           ::= { brzaccVLAutoSubBandFrequencySubsetEntry 2 }


    brzaccVLAutoSubBandFrequencySubsetActive   OBJECT-TYPE
            SYNTAX INTEGER  {active (1) , notActive (2)}
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB with SW version 4.0 and higher.
			 The status of an entry in the Auto Sub Band Frequency subset Table.
			 The frequency of an active entry will be included in the 
			 final list of frequencies to be used for scanning."
           ::= { brzaccVLAutoSubBandFrequencySubsetEntry 3 }

    brzaccVLAutoSubBandFrequencySubsetFrequency   OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB with SW version 4.0 and higher. 
             The frequency in MHz of the entry in the Auto Sub Band Frequency Subset table."
           ::= { brzaccVLAutoSubBandFrequencySubsetEntry 4 }


-- AUTOMATIC SUB BAND SELECT END


brzaccVLATPC   OBJECT IDENTIFIER ::= {brzaccVLAirInterface 13}

    brzaccVLAtpcOption  OBJECT-TYPE
            SYNTAX INTEGER	{ disable (1) , enable (2) , na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable all units.
             Enabling/disabling the ATPC Algorithm."
            ::= { brzaccVLATPC 1 }

    brzaccVLDeltaFromMinSNRLevel  OBJECT-TYPE
            SYNTAX INTEGER	 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable AU/BU only.
			 The Minimum SNR Level plus the value of this parameter define the 
			 maximum desired level of the average SNR at the AU/BU. 
			 If the ATPC Option is enabled,	than if the received SNR is above 
			 the maximum desired level, the AU/BU will transmit Power-Down 
			 messages to the applicable SU/RB.
             Range: 4 to 20 (dB)."
            ::= { brzaccVLATPC 2 }

    brzaccVLMinimumSNRLevel  OBJECT-TYPE
            SYNTAX INTEGER	 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable AU/BU only.
             Defines the minimum desired level of the average SNR at the AU/BU.
             Below this level, if *AtpcOption is enabled, the AU/BU will transmit
             ATPC Power-Up messages to the applicable SU/RB.
             The *MinimumSNRLevel cannot be higher  than *MaximumSNRLevel.
             Range: 4 to 60 (dB)."
            ::= { brzaccVLATPC 3 }


    brzaccVLMinimumIntervalBetweenATPCMessages  OBJECT-TYPE
            SYNTAX INTEGER	 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable AU/BU only.
			 The minimum interval between two consecutive AU/BU to SU/RB messages.
             Range: 1 to 3600 (Sec)."
            ::= { brzaccVLATPC 4 }



    brzaccVLPowerLevelSteps  OBJECT-TYPE
            SYNTAX INTEGER	 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable AU/BU only.
			 The step in dB that the SU/RB will use when receiving an ATPC 
			 Power-Up/Power-Down message.
             Range: 1 to 20  (dB)."
            ::= { brzaccVLATPC 6 }

brzaccVLCellDistanceParameters   OBJECT IDENTIFIER ::= {brzaccVLAirInterface 15}

    brzaccVLCellDistanceMode  OBJECT-TYPE
            SYNTAX INTEGER	{ automatic (1) , manual (2), na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable AU/BU only. 
             The selected mode of deciding on Cell Distance."
            ::= { brzaccVLCellDistanceParameters 1 }

  brzaccVLFairnessFactor  OBJECT-TYPE
            SYNTAX INTEGER { na (255)}	 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable AU/BU only.
             Not applicable to BreezeNET-B products for SW version below 4.0.
             The percentage of the maximum distance that is taken into 
             account in the time slot calculation. Range: 0 to 100 
             (Percent). A value of 0 means the minimal slot size 
             (9 microseconds).
             BreezeNET-B products with SW version below 4.0 return na."
            ::= { brzaccVLCellDistanceParameters 2 }

    brzaccVLMeasuredCellDistance  OBJECT-TYPE
            SYNTAX INTEGER {below-2-Km(1)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable AU/BU only.
			 The Maximum Cell Distance as calculated by the AU/BU.
             Range: 0 to 54 (Kilometers)."
            ::= { brzaccVLCellDistanceParameters 3 }

    brzaccVLUnitWithMaxDistance  OBJECT-TYPE
            SYNTAX MacAddress	 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable AU only.
			 Not applicable to BreezeNET-B units.
			 The MAC address of the unit with the maximum distance
			 from the AU."
            ::= { brzaccVLCellDistanceParameters 4 }
         
	brzaccVLPerSuDistanceLearning	OBJECT-TYPE
            SYNTAX INTEGER	{ disable (1) , enable (2) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Aplicable to AU only. Applicable only if Cell Distance Mode is 
			set to Automatic. When disabled, all SUs in the cell will use 
			for the ACK Timeout the computed distance of the farthest SU. 
			When enabled, each SU will use its own computed distance"
            ::= { brzaccVLCellDistanceParameters 5 }

   brzaccVLScanningMode OBJECT-TYPE
            SYNTAX  INTEGER  { passive (1), active (2)}
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to SU/RB only. 
             The scanning mode. In cells where the DFS Option is enabled 
             Scanning Mode is forced to Passive."
            ::= { brzaccVLAirInterface 16 }

   brzaccVLAntennaGain OBJECT-TYPE
            SYNTAX  DisplayString
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to all units. Read-write in units where 
             brzaccVLAntennaGainChange  is supported. 
             Read-only in units where brzaccVLAntennaGainChange is not supported. 
             The net gain (including cable attenuation for detached antennas) of 
             the antenna. 
             Range: 0  - to Maximum EIRP defined by country code + 10 (dBi). 
             A value of -2 (this value is configurable only in factory) 
             means don't care.
             A value of -1 (this value is configurable only in factory) 
             means that the unit will not transmit until the actual value 
             is configured."
            ::= { brzaccVLAirInterface 17 }

brzaccVLSpectrumAnalysisParameters       OBJECT IDENTIFIER ::= {brzaccVLAirInterface 18}

    brzaccVLSpectrumAnalysisChannelScanPeriod OBJECT-TYPE
            SYNTAX  INTEGER  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to all units. 
             The period of staying on each channel for information gathering 
             when performing Spectrum analysis. 
             Range: 2-30 seconds."
            ::= { brzaccVLSpectrumAnalysisParameters 1 }

    brzaccVLSpectrumAnalysisScanCycles OBJECT-TYPE
            SYNTAX  INTEGER  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to all units.  
             The number of scanning cycles when performing Spectrum Analysis. 
             Range: 1-100."
            ::= { brzaccVLSpectrumAnalysisParameters 2 }

    brzaccVLAutomaticChannelSelection OBJECT-TYPE
            SYNTAX  INTEGER  { disable (1), enable (2), na (255)}
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to AU/BU only.  
             Defines weather the AU/BU shall choose the most noise free channel
             upon startup after spectrum analysis."
            ::= { brzaccVLSpectrumAnalysisParameters 3 }

    brzaccVLSpectrumAnalysisActivation OBJECT-TYPE
            SYNTAX  INTEGER  { cancelOperation (1), activateNow (2)}
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to all units.  
             Activates spectrum analysis, the unit is automatically reset upon 
             activation."
            ::= { brzaccVLSpectrumAnalysisParameters 4 }

    brzaccVLSpectrumAnalysisStatus OBJECT-TYPE
            SYNTAX  INTEGER  { inactive (1), currentlyActive (2)}
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to all units.  
             Defines weather the unit is currently under performing 
             a spectrum analysis process."
            ::= { brzaccVLSpectrumAnalysisParameters 5 }

    brzaccVLResetSpectrumCounters OBJECT-TYPE
            SYNTAX  INTEGER  { cancelOperation (1), resetCounters (2)}
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to all units.  
             Resets the spectrum analysis counters."
            ::= { brzaccVLSpectrumAnalysisParameters 6 }

    brzaccVLSpectrumAnalysisInformationTable OBJECT-TYPE
            SYNTAX SEQUENCE OF BrzaccVLSpectrumAnalysisInformationEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to all units.  
             The spectrum analysis information table."
            ::= { brzaccVLSpectrumAnalysisParameters 7 }

    brzaccVLSpectrumAnalysisInformationEntry  OBJECT-TYPE
            SYNTAX BrzaccVLSpectrumAnalysisInformationEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to all units.  
             The spectrum analysis information table entry."
            INDEX { brzaccVLSpectrumAnalysisInformationTableIdx }
            ::= { brzaccVLSpectrumAnalysisInformationTable 1 }

    BrzaccVLSpectrumAnalysisInformationEntry ::= SEQUENCE {
            brzaccVLSpectrumAnalysisInformationTableIdx           INTEGER,
            brzaccVLSpectrumAnalysisInformationChannel            DisplayString,
            brzaccVLSpectrumAnalysisInformationSignalCount        INTEGER,
            brzaccVLSpectrumAnalysisInformationSignalSNR          INTEGER,
            brzaccVLSpectrumAnalysisInformationSignalWidth        INTEGER,
            brzaccVLSpectrumAnalysisInformationOFDMFrames         INTEGER
            }

         
    brzaccVLSpectrumAnalysisInformationTableIdx   OBJECT-TYPE
            SYNTAX INTEGER (1..60)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             A read only table index for a Spectrum Analysis Information entry in the  
             Spectrum Analysis Information Table."
        ::= { brzaccVLSpectrumAnalysisInformationEntry 1 }

    brzaccVLSpectrumAnalysisInformationChannel   OBJECT-TYPE
            SYNTAX DisplayString 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.  
             The channels in the Spectrum Analysis Information Table.
             If the unit is currently under spectrum analysis the channels would 
             be those on which the analysis is currently performed.
             If the unit is in normal mode the channels would be the those on 
             which the last analysis was performed."
        ::= { brzaccVLSpectrumAnalysisInformationEntry 2 }

    brzaccVLSpectrumAnalysisInformationSignalCount    OBJECT-TYPE
            SYNTAX INTEGER 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             The number of signals (excluding OFDM frames) detected in the channel. 
             If the unit is currently under spectrum analysis the count would 
             be of the analysis that is currently performed. 
             If the unit is in normal mode the count would be of the last 
             analysis performed."
        ::= { brzaccVLSpectrumAnalysisInformationEntry 3 }

    brzaccVLSpectrumAnalysisInformationSignalSNR   OBJECT-TYPE
            SYNTAX INTEGER 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
			 The approximate SNR of the signals (excluding OFDM frames)
			 detected in the channel.
			 If the unit is currently under spectrum analysis the SNR would
			 be of the analysis that is currently performed.
			 If the unit is in normal mode the SNR would be of the last
			 analysis performed."
        ::= { brzaccVLSpectrumAnalysisInformationEntry 4 }

    brzaccVLSpectrumAnalysisInformationSignalWidth   OBJECT-TYPE
            SYNTAX INTEGER 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units. 
             The average width of the signals (excluding OFDM frames) 
             detected in the channel. 
             If the unit is currently under spectrum analysis the width would 
             be of the analysis that is currently performed. 
             If the unit is in normal mode the width would be of the last 
             analysis performed."
        ::= { brzaccVLSpectrumAnalysisInformationEntry 5 }

    brzaccVLSpectrumAnalysisInformationOFDMFrames   OBJECT-TYPE
            SYNTAX INTEGER 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units. 
             The number of OFDM frames detected in the channel. 
             If the unit is currently under spectrum analysis the count would 
             be of the analysis that is currently performed. 
             If the unit is in normal mode the count would be of the last 
             analysis performed."
        ::= { brzaccVLSpectrumAnalysisInformationEntry 6 }

    brzaccVLMaxNumOfAssociationsLimit OBJECT-TYPE
            SYNTAX  INTEGER  
            MAX-ACCESS read-only      
            STATUS current       
            DESCRIPTION  
            "Applicable to AU only. 
             Not applicable to BreezeNET-B products. 
             Shows the limit for the number of SUs that can be associated 
             with the AU. 
             For AU-BS, AU-SA if Data Encryption is enabled, the upper 
             limit is 124, otherwise it is 512. 
             For AUS-BS, AUS-SA with SW version 4.0 and higher the upper limit 
             is 8 or 25 (via licensing).
             For AUS-BS, AUS-SA with SW version below 4.0 the upper limit is 5.
             BreezeNET-B products return 65535."
            ::= { brzaccVLAirInterface 19 }

brzaccVLDisassociate   OBJECT IDENTIFIER ::= {brzaccVLAirInterface 20}

    brzaccVLDisassociateAllSUs OBJECT-TYPE
            SYNTAX  INTEGER  { cancelOperation (1), disassociateAllSUs(2)}
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to AU only.  
             The AU shall disassociate all its associated units."
            ::= { brzaccVLDisassociate 1 }

    brzaccVLDisassociateSuByMacAddress OBJECT-TYPE
            SYNTAX  MacAddress 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to AU only.  
             The AU shall disassociate the SU with the configured MAC address."
            ::= { brzaccVLDisassociate 2 }

    brzaccVLTxControl OBJECT-TYPE
            SYNTAX  INTEGER  { on (1), off(2), ethernetStatusControl(3)}
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to AU/BU only.  
             Tx Control of the AU/BU.
             Starting with version 4.0 it is run-time.
             For SW version below 4.0 the unit reset itself.
             If set to ethernetStatusControl, the unit will not transmit 
             if the Ethernet link is down.
             This parameter can be configured only via the ethernet port."
            ::= { brzaccVLAirInterface 21 }

    brzaccVLLostBeaconsWatchdogThreshold OBJECT-TYPE
            SYNTAX  INTEGER  ( 0 | 100..1000 )
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to AU/BU only.  
            The number of unsuccessful consecutive transmissions beacons 
            before Internal refresh is performed. 
			0 means that the lost beacons watchdog is not 
			used and internal refresh is not performed."
			::= { brzaccVLAirInterface 22}     

    brzaccVLTransmitPower       OBJECT-TYPE
            SYNTAX INTEGER
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units with SW version 4.0 and higher.
             The uniform transmit power for all modulation levels. For a specific
             modulation level the effective transmit power (brzaccVLTxPower) is 
             the minimum between the uniform transmit power and the maximum 
             transmit power for that modulation level." 
            ::= { brzaccVLAirInterface 23 }
    
    brzaccVLMaximumTxPower       OBJECT-TYPE
            SYNTAX INTEGER
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to only SU/RB with SW version 4.0 and higher.
            The Maximum Transmit Power for all modulation levels.
            The Maximum Transmit Power for a specific modulation level is the 
            minimum between this parameter and the hardware limitation for 
            that modulation level" 
            ::= { brzaccVLAirInterface 24 }        
            
   brzaccVLCountryCodeParameters   OBJECT IDENTIFIER ::= {brzaccVLAirInterface 25}            
   
   brzaccVLCountryCodeReApply OBJECT-TYPE
	     	SYNTAX	INTEGER { reapply(1),cancel(2), na(255) }  
		    MAX-ACCESS read-write
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units.
             Re-apply country code parameters."
			::= { brzaccVLCountryCodeParameters 1 }

            
-- Service Params
-- ==============
   brzaccVLServiceParameters       OBJECT IDENTIFIER ::= {breezeAccessVLMib 7}

--    brzaccVLMirCirOption OBJECT-TYPE
--    SYNTAX  INTEGER {disable (1),
--                     enable (2), 
--                     na (255)} 
--        MAX-ACCESS read-write
--        STATUS current
--        DESCRIPTION 
--        "Applicable to AU and SU. Read-only in SU. 
--         The setting in the AU enables/disables the MIR/CIR support 
--         feature for all SUs served by the AU."
--    ::= { brzaccVLServiceParameters 1 }

    brzaccVLMirDownlink OBJECT-TYPE
        SYNTAX  INTEGER  
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to SU/RB only. 
         The Maximum Information Rate (MIR) from AU/BU to SU/RB.
         MIR must be above brzaccVLCirDownlink value.
         Range for set: 128 to 2,048 (Kbps) for SU-3 with SW version below 4.0,
						128 to 3,072 (Kbps) for SU-3 with SW version 4.0 and higher,				
                        128 to 3,968 (Kbps) for SU-6 with SW version less than 4.0,
                        128 to 6,016 (Kbps) for SU-6 with SW version greater than 4.0,
         	            128 to 14,976 (Kbps) for SU-24, 
         	            128 to 53,888 (Kbps) for SU-BD and SU-54,
         	            128 to 6,912  (Kbps) for RB-14, 
         	            128 to 22,016 (Kbps) for RB-28,
         	            128 to 107,904 (Kbps) for RB-100.
         	            128 to 6,016 (Kbps) for SU-I.
         The actual value (Get) will be the entered value rounded to the nearest 
         multiple of 128 (N*128)." 
    ::= { brzaccVLServiceParameters 2 }
   
    brzaccVLMirUplink OBJECT-TYPE
        SYNTAX INTEGER  
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to SU/RB only. 
         The Maximum Information Rate (MIR) from SU/RB to AU/BU.
         MIR must be above brzaccVLCirUplink value.
         Range for set: 128 to 2,048 (Kbps) for SU-3,
                        128 to 3,968  (Kbps) for SU-6 with SW version less than 4.0,
                        128 to 4,096  (Kbps) for SU-6 with SW version greater than 4.0,
         	            128 to 14,976 (Kbps) for SU-24, 
         	            128 to 53,888 (Kbps) for SU-BD and SU-54,
         	            128 to 6,912  (Kbps) for RB-14, 
         	            128 to 22,016 (Kbps) for RB-28, 
         	            128 to 107,904 (Kbps) for RB-100.
         	            128 to 2,048 (Kbps) for SU-I.
		 The actual value (Get) will be the entered value rounded to the nearest 
		 multiple of 128 (N*128)." 
    ::= { brzaccVLServiceParameters 3 }

   
    brzaccVLCirDownlink OBJECT-TYPE
        SYNTAX INTEGER  
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to SU only. 
         Not applicable to BreezeNET-B products. 
         The Committed Information Rate (CIR) from AU to SU.
         CIR must be below brzaccVLMirDownlink value.
         Range for Set: 
         0 to 2,048 (Kbps) for SU-3 with SW version below 4.0,
		 0 to 3,072 (Kbps) for SU-3 with SW version 4.0 and higher,				
         0 to 3,968 (Kbps) for SU-6 with SW version less than 4.0,
         0 to 6,016 (Kbps) for SU-6 with SW version greater than 4.0
         0 to 14,976 (Kbps) for SU-24, 
         0 to 45,056 (Kbps) for SU-BD and SU-54. 
         0 to 6,016 (Kbps) for SU-I.
         The actual value (Get) will be the entered value rounded to the 
         nearest multiple of 128 (N*128).
		 BreezeNET-B products will return 65535."
    ::= { brzaccVLServiceParameters 4 }

   
    brzaccVLCirUplink OBJECT-TYPE	  
         SYNTAX INTEGER  
         MAX-ACCESS read-write
         STATUS current
         DESCRIPTION  
         "Applicable to SU only. 
          Not applicable to BreezeNET-B products. 
          The Committed Information Rate (CIR) from SU to AU.
          CIR must be below brzaccVLMirUplink value.
          Range for Set: 
          0 to 2,048 (Kbps) for SU-3,
          0 to 3,968  (Kbps) for SU-6 with SW version less than 4.0,
          0 to 4,096  (Kbps) for SU-6 with SW version greater than 4.0,
          0 to 14,976 (Kbps) for SU-24, 
          0 to 45,056 (Kbps) for SU-BD and SU-54. 
          0 to 2,048 (Kbps) for SU-I.
          The actual value (Get) will be the entered value rounded to the nearest 
          multiple of 128 (N*128).
          BreezeNET-B products will return 65535."
    ::= { brzaccVLServiceParameters 5 }


    brzaccVLMaxDelay OBJECT-TYPE
        SYNTAX INTEGER  
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to SU only. 
         Not applicable to BreezeNET-B products.
         The maximal time packets may be delayed by the 
         CIR\MIR mechanism. Above the configured maximal period 
         the packets are discarded.
         Range: 300 to 10000 milliseconds.
         BreezeNET-B products return 65535."
    ::= { brzaccVLServiceParameters 6 }

    brzaccVLMaxBurstDuration OBJECT-TYPE
        SYNTAX INTEGER  
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to AU and SU. 
         Not applicable to BreezeNET-B products.
         The maximum time during which inactivity bonus time 
         can be accumulated for future burst transmissions.
         Range: 0 to 2000 milliseconds.
         BreezeNET-B products return 65535"
    ::= { brzaccVLServiceParameters 7 }

    brzaccVLGracefulDegradationLimit OBJECT-TYPE
        SYNTAX INTEGER  
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to AU only. 
         Not applicable to BreezeNET-B products.
         The maximum limit for activating the graceful 
         degradation algorithm.
         Range: 0 to 70% rate of the CIR.
         BreezeNET-B products return 255."
    ::= { brzaccVLServiceParameters 8 }

    brzaccVLMirOnlyOption OBJECT-TYPE
        SYNTAX  INTEGER {disable (1), enable (2), na (255)} 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to AU only. 
         Not applicable to BreezeNET-B products. 
         When brzaccMirOnly is enabled, it overrides the CIR/MIR 
         algorithm for determining actual information rate and 
         forces the algorithm to operate with MIR parameter 
         settings only. When enabled, the Graceful Degradation 
         algorithm is disabled."
    ::= { brzaccVLServiceParameters 9 }


brzaccVLTrafficPrioritization OBJECT IDENTIFIER ::= {brzaccVLServiceParameters 10}

brzaccVLTrafficPriVLAN OBJECT IDENTIFIER ::= {brzaccVLTrafficPrioritization 1}

brzaccVLVLANPriorityThreshold OBJECT-TYPE
        SYNTAX  INTEGER (1..7)
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to all units. 
        If the VLAN Priority's value of the frame is less than or equal to this
        threshold the frame will get LOW priority, otherwise the frame will get 
        HIGH priority.
        Untagged frames will get LOW priority"
    ::= { brzaccVLTrafficPriVLAN 1 }


brzaccVLTrafficPriIPToS OBJECT IDENTIFIER ::= {brzaccVLTrafficPrioritization 2}

brzaccVLToSPrioritizationOption OBJECT-TYPE
        SYNTAX  INTEGER {disable(1), ipPrecedence(2), dSCP(3) } 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
		"Applicable to all units. Disable/Enable IP ToS prioritization and 
		choose the interpretation of the IP ToS field from IP header.
		ipPrecedence(2): The IP ToS field is defined by RFC791. In this 
                         case the prioritization will be done using the 
                         Precedence sub-field of IP ToS. This sub-field 
                         has 3 bits, so it can be between 0 and 7.
		dSCP(3):         The IP ToS field is defined by RFC2474. In this
                         case the prioritization will be done using the 
                         DSCP sub-field. The size of the sub-field is 6 bits, 
                         so the range is 0 to 63."
    ::= { brzaccVLTrafficPriIPToS 1 }

brzaccVLIPPrecedenceThreshold OBJECT-TYPE
        SYNTAX  INTEGER (0..7)
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
		"Applicable to all units. The threshold of Precedence sub-field of IP ToS 
		field from IP Header (RFC791) to be used when the ToS Prioritization 
		Option is set to IP Precedence.
		If the Precedence sub-field of a frame is less than or equal to this 
		threshold the frame will have LOW priority, otherwise it will get HIGH 
		priority."
    ::= { brzaccVLTrafficPriIPToS 2 }

brzaccVLIPDSCPThreshold OBJECT-TYPE
        SYNTAX  INTEGER (0..63)
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
		"Applicable to all units. The threshold of DSCP sub-field of IP ToS 
		field from IP Header (RFC2474) to be used when ToS Prioritization 
		Option is set to DSCP.
		If the DSCP sub-field of a frame is less than or equal to this 
		threshold the frame will have LOW priority, otherwise it will get 
		HIGH priority."
    ::= { brzaccVLTrafficPriIPToS 3 }
 
        
brzaccVLTrafficPriUdpTcpPortRange OBJECT IDENTIFIER ::= {brzaccVLTrafficPrioritization 3}

brzaccVLUdpTcpPortRangePrioritizationOption OBJECT-TYPE
        SYNTAX  INTEGER {disable(1), udpOnly(2), tcpOnly(3), udpANDtcp(4) } 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to all units. Disable/Enable Prioritization using UDP and/or
        TCP Port Ranges. 
		udpOnly(2)  : prioritization will be done only for UDP packets
		tcpOnly(3)  : prioritization will be done only for TCP packets
		udpANDtcp(4): prioritization will be done for UDP and TCP packets"
    ::= { brzaccVLTrafficPriUdpTcpPortRange 1 }

brzaccVLUdpPortRangeConfig OBJECT IDENTIFIER ::= {brzaccVLTrafficPriUdpTcpPortRange 2}

brzaccVLUdpPortPriRTPRTCP OBJECT-TYPE
        SYNTAX  INTEGER {rtpANDrtcp(1),rtpOnly(2) } 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicale to all units.
        RTP/RTCP ports prioritization option for UDP packets. 
        rtpANDrtcp(1): the possible RTP and RTCP packet with destination port in the
                       defined port ranges will get HIGH priority
		rtpOnly(2): only possible RTP packet (packet with even destination port ) 
		            with destination port in the defined port ranges will get HIGH 
		            priority."
    ::= { brzaccVLUdpPortRangeConfig 1 }

brzaccVLUdpPortRangeNum OBJECT-TYPE
        SYNTAX  INTEGER 
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION 
        "Applicable to all units. The number of entries in the UDP Port Range Table"
    ::= { brzaccVLUdpPortRangeConfig 2 }
    
brzaccVLUdpPortRangeTable OBJECT-TYPE
        SYNTAX SEQUENCE OF BrzaccVLUdpPortRangeEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
		"Applicable to all units. A table of UDP port ranges use for prioritization. 
		The user can define up to 64 ranges.
        An entry is empty if start is 65535 and end is 0"
        ::= { brzaccVLUdpPortRangeConfig 3 }

brzaccVLUdpPortRangeEntry  OBJECT-TYPE
        SYNTAX BrzaccVLUdpPortRangeEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
        "Applicable to all units. A UDP Port Ranges Table entry." 
        INDEX { brzaccVLUdpPortRangeIdx }
        ::= { brzaccVLUdpPortRangeTable 1 }

BrzaccVLUdpPortRangeEntry ::= SEQUENCE {
        brzaccVLUdpPortRangeStart INTEGER,
        brzaccVLUdpPortRangeEnd INTEGER,
        brzaccVLUdpPortRangeIdx INTEGER
        }
            
brzaccVLUdpPortRangeStart OBJECT-TYPE
        SYNTAX INTEGER(0..65535)  
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION 
        "Applicable to all units. Start port of an UDP Port Range"
        ::= { brzaccVLUdpPortRangeEntry 1 }

brzaccVLUdpPortRangeEnd OBJECT-TYPE
        SYNTAX INTEGER(0..65535)  
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION 
        "Applicable to all units. End port of an UDP Port Range"
        ::= { brzaccVLUdpPortRangeEntry 2 }
           
brzaccVLUdpPortRangeIdx OBJECT-TYPE
        SYNTAX INTEGER(1..64)  
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION 
        "Applicable to all units. UDP Port Range Entry's index "
        ::= { brzaccVLUdpPortRangeEntry 3 }


brzaccVLUdpPortRangeAdd OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..250)) 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to all units. Add port range(s) to UDP Port Ranges Table. 
        Get operation will return the empty string. 
		A range is defined <start>-<end> or <start> where <start> is the Start 
		Port of the range and <end> is the End Port. If only <start> is 
		specified the range is <start>-<start>.
        The value of  <start> and <end> are between 0..65535.
        The user can add several ranges using a comma to separate between ranges. 
        Example: 10-256,99,987-900"
    ::= { brzaccVLUdpPortRangeConfig 4 }
    
brzaccVLUdpPortRangeDelete OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..250)) 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to all units. Delete port range(s) from UDP Port Ranges Table. 
        Get operation will return the empty string.
        A range is defined <start>-<end> or <start> where <start> is the Start 
        Port of the range and <end> is the End Port. If only <start> is 
        specified the range is <start>-<start>.
        The value of  <start> and <end> are between 0..65535.
        The user can delete several ranges using a comma to separate between 
        ranges.
        Example: 10-256,99,987-900"
    ::= { brzaccVLUdpPortRangeConfig 5 }

brzaccVLUdpPortRangeDeleteAll OBJECT-TYPE
        SYNTAX INTEGER { deleteAll(1), cancelOperation(2) }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
		"Applicable to all units. Delete all entries form UDP Port Ranges Table. 
		Get operation will return 1"
    ::= { brzaccVLUdpPortRangeConfig 6 }



brzaccVLTcpPortRangeConfig OBJECT IDENTIFIER ::= {brzaccVLTrafficPriUdpTcpPortRange 3}

brzaccVLTcpPortPriRTPRTCP OBJECT-TYPE
        SYNTAX  INTEGER {rtpANDrtcp(1),rtpOnly(2) } 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to all units. RTP/RTCP ports prioritization option for TCP packets. 
		rtpANDrtcp(1): the possible RTP and RTCP packet with destination port 
		in the defined port ranges will get HIGH priority
		rtpOnly(2): only possible RTP packet (packet with even destination port )"
    ::= { brzaccVLTcpPortRangeConfig 1 }

brzaccVLTcpPortRangeNum OBJECT-TYPE
        SYNTAX  INTEGER 
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION 
        "Applicable to all units. The number of entries in the TCP Port Range Table"
    ::= { brzaccVLTcpPortRangeConfig 2 }
    
brzaccVLTcpPortRangeTable OBJECT-TYPE
        SYNTAX SEQUENCE OF BrzaccVLTcpPortRangeEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
        "Table of TCP Port Ranges use for prioritization.
        The user can define up to 64 ranges.
        An entry is empty if start is 65535 and end is 0"
        ::= { brzaccVLTcpPortRangeConfig 3 }

brzaccVLTcpPortRangeEntry  OBJECT-TYPE
        SYNTAX BrzaccVLTcpPortRangeEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
        "Applicable to all units. A TCP Port Ranges Table entry." 
        INDEX { brzaccVLTcpPortRangeIdx }
        ::= { brzaccVLTcpPortRangeTable 1 }

BrzaccVLTcpPortRangeEntry ::= SEQUENCE {
        brzaccVLTcpPortRangeStart INTEGER,
        brzaccVLTcpPortRangeEnd INTEGER,
        brzaccVLTcpPortRangeIdx INTEGER
        }
            
brzaccVLTcpPortRangeStart OBJECT-TYPE
        SYNTAX INTEGER(0..65535)  
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION 
        "Applicable to all units. Start port of a TCP Port Range"
        ::= { brzaccVLTcpPortRangeEntry 1 }

brzaccVLTcpPortRangeEnd OBJECT-TYPE
        SYNTAX INTEGER(0..65535)  
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION 
        "Applicable to all units. End port of a TCP Port Range"
        ::= { brzaccVLTcpPortRangeEntry 2 }
           
brzaccVLTcpPortRangeIdx OBJECT-TYPE
        SYNTAX INTEGER(1..64)  
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION 
        "Applicable to all units. TCP Port Range Entry's index"
        ::= { brzaccVLTcpPortRangeEntry 3 }


brzaccVLTcpPortRangeAdd OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..250)) 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to all units. Add port range(s) to TCP Port Ranges Table. 
        Get operation will return the empty string. 
		A range is defined <start>-<end> or <start> where <start> is the Start 
		Port of the range and <end> is the End Port. If only <start> is specified 
		the range is <start>-<start>.
        The value of  <start> and <end> are between 0..65535.
        The user can add several ranges using comma to separate between ranges.
        Example: 10-256,99,987-900"
    ::= { brzaccVLTcpPortRangeConfig 4 }
    
brzaccVLTcpPortRangeDelete OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..250)) 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
		"Applicable to all units. Delete port range(s) from TCP Port Ranges Table. 
		Get operation will return the empty string.
        A range is defined <start>-<end> or <start> where <start> is the Start 
        Port of the range and <end> is the End Port. If only <start> is specified 
        the range is <start>-<start>.
        The value of  <start> and <end> are between 0..65535.
        The user can delete several ranges using comma to separate between ranges.
        Example: 10-256,99,987-900"
    ::= { brzaccVLTcpPortRangeConfig 5 }

brzaccVLTcpPortRangeDeleteAll OBJECT-TYPE
        SYNTAX INTEGER { deleteAll(1), cancelOperation(2) }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to all units. Delete all entries form TCP Port Ranges Table
        Get operation will return 1"
    ::= { brzaccVLTcpPortRangeConfig 6 }
    
brzaccVLWirelessLinkPrioritization OBJECT IDENTIFIER ::= {brzaccVLTrafficPrioritization 4}

brzaccVLWirelessLinkPrioritizationOption OBJECT-TYPE
            SYNTAX  INTEGER  { disable(1), enable(2), na(255) }
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. 
             Enable/disable the traffic prioritization over the 
             Wireless Link"
            ::= { brzaccVLWirelessLinkPrioritization  1}

brzaccVLlowPriorityAIFS OBJECT-TYPE
            SYNTAX  INTEGER  (3..254)
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. 
            Applicable only if the Wireless Link Prioritization Option is enabled.
            Define the AIFS (Arbitration Inter-frame Space) that will be used   
            for transmitting Low Priority Traffic"
            ::= { brzaccVLWirelessLinkPrioritization  2}

brzaccVLHWRetriesHighPriority OBJECT-TYPE
            SYNTAX  INTEGER (0..14)
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
            Applicable only if the Wireless Link Prioritization Option is enabled. 
            Defines the Maximum number of HW Retries for a unicast data packet 
            that has High Priority"
            ::= { brzaccVLWirelessLinkPrioritization  3}
            
brzaccVLHWRetriesLowPriority OBJECT-TYPE
            SYNTAX  INTEGER (0..14)
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
            Applicable only if the Wireless Link Prioritization Option is enabled. 
            Defines the Maximum number of HW Retries for a unicast data packet 
            that has Low Priority"
            ::= { brzaccVLWirelessLinkPrioritization 4}
            
brzaccVLAUBurstDurationHighPriority OBJECT-TYPE
            SYNTAX  INTEGER  (0..40)
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. 
            Applicable only if the Wireless Link Prioritization Option is enabled.
             Defines the Maximum duration of burst that can be done by AU with 
             High Priority packets.
             The time is given in 250 microseconds units"
            ::= { brzaccVLWirelessLinkPrioritization  5}
            
brzaccVLAUBurstDurationLowPriority OBJECT-TYPE
            SYNTAX  INTEGER  (0..40)
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. 
            Applicable only if the Wireless Link Prioritization Option is enabled.
             Defines the Maximum duration of burst that can be done by AU 
             with Low Priority packets.
             The time is given in 250 microseconds units"
            ::= { brzaccVLWirelessLinkPrioritization  6}
            
brzaccVLSUBurstDurationHighPriority OBJECT-TYPE
            SYNTAX  INTEGER (0..40)
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. 
            Applicable only if the Wireless Link Prioritization Option is enabled.
            Defines the Maximum duration of burst that can be done by SU/RB 
            with High Priority packets.
            The parameter is configurable in AU and the SUs/RB will learn it 
            form AU/BU.
            The time is given in 250 microseconds units"
            ::= { brzaccVLWirelessLinkPrioritization  7}

brzaccVLSUBurstDurationLowPriority OBJECT-TYPE
            SYNTAX  INTEGER (0..40)
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. 
            Applicable only if the Wireless Link Prioritization Option is enabled.
            Defines the Maximum duration of burst that can be done by SU/RB 
            with High Priority packets.
            The parameter is configurable in AU/BU and the SUs/RB will learn it 
            from AU/BU.
            The time is given in 250 microseconds units"
            ::= { brzaccVLWirelessLinkPrioritization  8}


--DRAP BEGIN

brzaccVLDrap OBJECT IDENTIFIER ::= { brzaccVLServiceParameters 11 }

brzaccVLDrapSupport OBJECT-TYPE
		SYNTAX INTEGER {disable(1), enable(2), na(255)}
		MAX-ACCESS read-write
		STATUS current
		DESCRIPTION
		"Applicable to AU. Not applicable to BreezeNET B products
		Disable/Enable the DRAP feature" 
		::= { brzaccVLDrap 1 }

brzaccVLDrapUdpPort OBJECT-TYPE
		SYNTAX INTEGER (8000..8200)
		MAX-ACCESS read-write
		STATUS current
		DESCRIPTION
		"Applicable to AU when DRAP support is enabled. 
		Not applicable to BreezeNET B products. 
		The UDP port used for the DRAP server"
		::= { brzaccVLDrap 2 }

brzaccVLDrapMaxNumberOfVoiceCalls OBJECT-TYPE
		SYNTAX INTEGER (0..255)
		MAX-ACCESS read-write
		STATUS current
		DESCRIPTION
		"Applicable to AU when DRAP support is enabled. 
		Not applicable to BreezeNET B products. 
		The maximum number of voice calls that can be supported by the AU"
		::= { brzaccVLDrap 3 }

brzaccVLDrapTTL OBJECT-TYPE
		SYNTAX INTEGER (1..255)
		MAX-ACCESS read-write
		STATUS current
		DESCRIPTION
		"Applicable to AU when DRAP support is enabled. 
		Not applicable to BreezeNET B products. 
		The maximum time between two allocation requests"
		::= { brzaccVLDrap 4 }

brzaccVLDrapNoOfActiveVoiceCalls OBJECT-TYPE
        SYNTAX INTEGER
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION 
		"Applicable to AU when DRAP support is enabled. 
		Not applicable to BreezeNET B products. 
		The current total number of  active voice calls."
        ::= { brzaccVLDrap 5 }


--DRAP END

brzaccVLLowPriorityTrafficMinimumPercent OBJECT-TYPE
		SYNTAX INTEGER (0..100)
		MAX-ACCESS read-write
		STATUS current
		DESCRIPTION 
		"The minimum percent of the traffic rate that is allocated to the low priority traffic"
		::= { brzaccVLServiceParameters 12 }
				

brzaccVLSUPMirDownlink OBJECT-TYPE
        SYNTAX  INTEGER  
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to AU only. 
         The Maximum Information Rate (MIR) from AU to SUP.
            Range for set: 128 to 12,032 (Kbps).
         The actual value (Get) will be the entered value rounded to the nearest 
         multiple of 128 (N*128)." 
    ::= { brzaccVLServiceParameters 13 }
   
brzaccVLMIRThresholdPercent OBJECT-TYPE
        SYNTAX  INTEGER (0..100)  
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION 
        "Applicable to AU only. 
		MIR Threshold Percent" 
    ::= { brzaccVLServiceParameters 14 }		
 
-- User Filtering Params
-- =====================
   brzaccVLUserFilterParams   OBJECT IDENTIFIER ::= {breezeAccessVLMib 8}

    brzaccVLUserFilterOption OBJECT-TYPE
            SYNTAX INTEGER { disable (1), 
                             ipOnly (2), 
                             userDefinedAddrOnly (3), 
                             pPPoEOnly (4), 
                             na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB only. 
             Defines user-filtering options.
             disable: No filtering.
             iPOnly: Only IP protocol frames pass. 
             userDefinedAddrOnly: Only ip frames to/from user defined IP 
                                  addresses pass.
             pPPoE Only: Only PPPoE frames pass."
             ::= { brzaccVLUserFilterParams 1 }

    brzaccVLIpFilterTable OBJECT-TYPE
            SYNTAX SEQUENCE OF BrzaccVLIpFilterEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to SU/RB only. 
             An IP Filter Table of up to 8 user defined addresses, 
             or address groups, to be used if the selected User 
             Filtering option is userDefinedAddrOnly." 
            ::= { brzaccVLUserFilterParams 2 }

    brzaccVLIpFilterEntry  OBJECT-TYPE
            SYNTAX BrzaccVLIpFilterEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to SU/RB only. 
             An IP Filter Table entry." 
            INDEX { brzaccVLIpFilterIdx }
            ::= { brzaccVLIpFilterTable 1 }

   BrzaccVLIpFilterEntry ::= SEQUENCE {
            brzaccVLIpID   IpAddress,
            brzaccVLMaskID IpAddress,
            brzaccVLIpFilterRange INTEGER,
            brzaccVLIpFilterIdx INTEGER
            }
               
    brzaccVLIpID   OBJECT-TYPE
            SYNTAX IpAddress  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB only. 
             An IP address of an IP Filter Table entry."
           ::= { brzaccVLIpFilterEntry 1 }

    brzaccVLMaskID OBJECT-TYPE
            SYNTAX IpAddress  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB only. 
             An IP Mask of an IP Filter Table entry. Either a mask 
             or a range, but not both can be used to define an 
             address group. If the range is other than 0, than the mask is 
             ignored and only the range value is used to define the address group."
           ::= { brzaccVLIpFilterEntry 2 }
   
    brzaccVLIpFilterRange OBJECT-TYPE
            SYNTAX INTEGER 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB only. 
             An addresses range for the IP Filter Table entry. The 
             first address in the range is the IP address.
             O means that the range is not used.  
             Either a mask or a range, but not both can be used to 
             define an address group.
			 If the range is other than 0, than the mask is ignored and 
			 only the range value is used to define the address group.
             Range: 0 to 255."
            ::= { brzaccVLIpFilterEntry 3 }

    brzaccVLIpFilterIdx   OBJECT-TYPE
            SYNTAX INTEGER  (1..8)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB only. 
             A table index for the IP Filter Table entry." 
         ::= { brzaccVLIpFilterEntry 4 }

    brzaccVLDeleteOneUserFilter OBJECT-TYPE
            SYNTAX  INTEGER { deletefirstEntry  (1), deletesecondEntry (2), 
                              deletethirdEntry  (3), deletefourthEntry (4), 
                              deletefifthEntry  (5), deletesixthEntry (6), 
                              deleteseventhEntry(7), deleteeighthEntry (8), 
                              cancelOperation   (9), na (255) } 
 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB only. 
             Deletes a single selected entry from the IP Filter 
             Table."
            ::= { brzaccVLUserFilterParams 3 }

    brzaccVLDeleteAllUserFilters OBJECT-TYPE
            SYNTAX  INTEGER { deleteAll (1), cancelOperation (2),  
                              na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB only. 
             Deletes all entries from the IP Filter Table."
            ::= { brzaccVLUserFilterParams 4 }

    brzaccVLDHCPUnicastOverrideFilter OBJECT-TYPE
            SYNTAX  INTEGER { disable (1), enable (2), na (255) } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only. 
             Enables or disables the unicast DHCP messages, 
             overriding the IP Filtering option." 
            ::= { brzaccVLUserFilterParams 5 }


	 
-- Security Params
-- ==================
brzaccVLSecurityParameters     OBJECT IDENTIFIER ::= {breezeAccessVLMib 9}

    brzaccVLAuthenticationAlgorithm OBJECT-TYPE
            SYNTAX  INTEGER  {openSystem(1) , sharedKey(2)}
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
            Enables/disables the authentication encryption option.
            openSystem: Authentication messages are not encrypted.
            sharedKey : Authentication messages are encrypted "
            ::= { brzaccVLSecurityParameters 1 }

    brzaccVLSUDefaultKeyID OBJECT-TYPE
            SYNTAX  INTEGER  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB only.
			 The key to be used for encryption of authentication messages 
			 and/or data.
             Range: 1 to 4. "
            ::= { brzaccVLSecurityParameters 2 }

    brzaccVLDataEncryptionOption OBJECT-TYPE
            SYNTAX  INTEGER  {disable(1) , enable(2)}
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             Enables/disables the data encryption option. "
            ::= { brzaccVLSecurityParameters 3 }

    brzaccVLAUDefaultMulticastKeyID OBJECT-TYPE
            SYNTAX  INTEGER  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU only.
             The key to be used for encryption of multicasts and broadcasts."
            ::= { brzaccVLSecurityParameters 4 }

    brzaccVLSecurityMode OBJECT-TYPE
            SYNTAX  INTEGER   {wep(1) , aesOCB(2), fips197(3)}
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units. The fips197 option is applicable only to units with a license to
             use FIPS 197 algorithm.
             The encryption algorithm to be used for authentication messages 
             and/or data encryption."
            ::= { brzaccVLSecurityParameters 5 }


    brzaccVLAuthenticationPromiscuousMode OBJECT-TYPE
            SYNTAX  INTEGER   {disable(1) , enable(2)}
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU only.
             Enables/disable the promiscuous mode allowing authentication of 
             and communication with all SUs/RB regardless of their security 
             parameters."
            ::= { brzaccVLSecurityParameters 6 }


    brzaccVLKey1 OBJECT-TYPE
            SYNTAX  DisplayString (SIZE(32))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             Key number 1. Accessible only with SNMP Write Community String 
             (administrator password).
             Valid values: 32 hexadecimal digits."
            ::= { brzaccVLSecurityParameters 7 }

    brzaccVLKey2 OBJECT-TYPE
            SYNTAX  DisplayString (SIZE(32))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             Key number 2. Accessible only with SNMP Write Community String 
             (administrator password).
             Valid values: 32 hexadecimal digits."
            ::= { brzaccVLSecurityParameters 8 }

    brzaccVLKey3 OBJECT-TYPE
            SYNTAX  DisplayString (SIZE(32))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             Key number 3. Accessible only with SNMP Write Community String 
             (administrator password).
             Valid values: 32 hexadecimal digits."
            ::= { brzaccVLSecurityParameters 9 }

    brzaccVLKey4 OBJECT-TYPE
            SYNTAX  DisplayString (SIZE(32))
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             Key number 4. Accessible only with SNMP Write Community String 
             (administrator password).
             Valid values: 32 hexadecimal digits."
            ::= { brzaccVLSecurityParameters 10 }

    brzaccVLSecurityModeSupport OBJECT-TYPE
            SYNTAX  INTEGER (0..7)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to all units. Returns types of encryption that are supported.
            0 - no encryption
            1 - WEP
            2 - AES OCB
            3 - WEP and AES OCB
            4 - FIPS-197
            5 - FIPS-197 and WEP
            6 - FIPS-197 and AES OCB
            7 - FIPS-197, AES OCB and WEP"
            ::= { brzaccVLSecurityParameters 12 }

--brzaccVLSecurityPermission     OBJECT IDENTIFIER ::= {brzaccVLSecurityParameters 12}
--
--    brzaccVLDataEncryptionPermission   OBJECT-TYPE
--            SYNTAX INTEGER  {permitted(1), notPermitted(2)}
--            MAX-ACCESS read-only
--            STATUS current
--            DESCRIPTION 
--            "."
--           ::= { brzaccVLSecurityPermission 1 }
--
--    brzaccVLEncryptionByAESPermission   OBJECT-TYPE
--            SYNTAX INTEGER  {permitted(1), notPermitted(2)}
--            MAX-ACCESS read-only
--            STATUS current
--            DESCRIPTION 
--            "."
--           ::= { brzaccVLSecurityPermission 2 }
--
-- 
--    brzaccVLAuthenticationBySharedKeyAlgorithmPermission   OBJECT-TYPE
--            SYNTAX INTEGER  {permitted(1), notPermitted(2)}
--            MAX-ACCESS read-only
--            STATUS current
--            DESCRIPTION 
--            "."
--           ::= { brzaccVLSecurityPermission 3 }


-- Performance Params
-- ==================
brzaccVLPerformanceParams     OBJECT IDENTIFIER ::= {breezeAccessVLMib 10}

    brzaccVLRTSThreshold OBJECT-TYPE
            SYNTAX  INTEGER  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU and AU. 
             Not applicable to BreezeNET-B products. 
             The minimum frame size that requires an RTS/CTS handshake.            
             Range: For units bearing SW version 3.0 and above: 20 to 3400 bytes,
			 for previous SW versions 20 to 1600 bytes.
             BreezeNET-B products return 65535."
            ::= { brzaccVLPerformanceParams 1 }

    brzaccVLMinContentionWindow OBJECT-TYPE
            SYNTAX  INTEGER  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU and AU. 
             For units bearing SW version 4.0 and above applicable to 
             BreezeNET-B products, for previous SW versions not applicable 
             to BreezeNET-B products. 
             The initial value to be used by the contention window calculation 
             algorithm.
             Value must be 0 or power of 2 minus 1 (7,15,31...).
             Range: 0 to 1023, excluding 1 and 3.
             BreezeNET-B products with SW version below 4.0 return 65535."
            ::= { brzaccVLPerformanceParams 3 }

    brzaccVLMaxContentionWindow OBJECT-TYPE
            SYNTAX  INTEGER  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to SU and AU. 
             For units bearing SW version 4.0 and above applicable to 
             BreezeNET-B products, for previous SW versions not applicable 
             to BreezeNET-B products. 
             The maximum value to be used by the contention window calculation 
             algorithm.
             Value must be power of 2 minus 1 (7,15,31...)
             Range: 7 to 1023."
            ::= { brzaccVLPerformanceParams 4 }

    brzaccVLMaximumModulationLevel OBJECT-TYPE
            SYNTAX  INTEGER { level1 (1), 
                              level2 (2), 
                              level3 (3), 
                              level4 (4), 
                              level5 (5), 
                              level6 (6), 
                              level7 (7),
                              level8 (8)
                            } 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             If the Adaptive Modulation algorithm is enabled, it sets the 
             Maximum Modulation Level to be used.
             If The Modulation algorithm is disabled, it sets the Fixed 
             Modulation Level to be used.
			 The range is 1 to 8. 8 is not applicable for units with HW revision A." 
            ::= { brzaccVLPerformanceParams 5 }

    brzaccVLMulticastModulationLevel OBJECT-TYPE
            SYNTAX  INTEGER { level1 (1), 
                              level2 (2), 
                              level3 (3), 
                              level4 (4), 
                              level5 (5), 
                              level6 (6), 
                              level7 (7),
                              level8 (8) 
                            } 
 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to AU/BU only.
             The modulation level for multicast and broadcast data frames.
			 The range is 1 to 8.
			 8 is not applicable for units with HW revision A." 
            ::= { brzaccVLPerformanceParams 6 }

    brzaccVLAvgSNRMemoryFactor  OBJECT-TYPE
            SYNTAX DisplayString	 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
			 The weight of history in average SNR calculation.
			 The higher is the value, the higher is the weight of history.
             Range: -1 (Disregard History) to 32."
            ::= { brzaccVLPerformanceParams 7 }

    brzaccVLHardwareRetries OBJECT-TYPE
            SYNTAX  INTEGER  
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable to all units.
             Not applicable if Wireless Link Prioritization is enabled.
             The maximum number of trials to transmit an unacknowledged 
             frame in each Hardware Retrial phase.
             Range : 1 to 14." 
            ::= { brzaccVLPerformanceParams 8 }


brzaccVLAdaptiveModulationParams     OBJECT IDENTIFIER ::= {brzaccVLPerformanceParams 9}

    brzaccVLAdaptiveModulationAlgorithmOption OBJECT-TYPE
            SYNTAX  INTEGER  {   disable (1) , enable (2), na (255) }
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to all units. 
             Enables/disables the adaptive modulation level decision mechanism."
            ::= { brzaccVLAdaptiveModulationParams  1 }


    brzaccVLSoftwareRetrySupport OBJECT-TYPE
            SYNTAX  INTEGER  {   disable (1) , enable (2), na (255) }
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to all units. 
             Read-only for units with version 2.0. 
             Not applicable for units with SW version 3.0 and higher. 
             The status of the Software Retry mechanism. 
             Enabled when the Adaptive Modulation algorithm is enabled and 
             the Burst Mode Option is disabled. Otherwise it is disabled." 
            ::= { brzaccVLAdaptiveModulationParams  2 }


    brzaccVLNumOfSoftwareRetries OBJECT-TYPE
            SYNTAX  INTEGER { na (255) }
            MAX-ACCESS read-write 
            STATUS current
            DESCRIPTION  
            "Applicable to all units. 
             Read-only for units with version 2.0. 
             Not applicable for units with SW version 3.0 and higher. 
             The maximum number of times to use the Software Retry mechanism 
             when it is enabled."
            ::= { brzaccVLAdaptiveModulationParams 3 }



    brzaccVLMinIntervalBetweenAdaptiveModulationAlgorithmMessages  OBJECT-TYPE
            SYNTAX INTEGER	 
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION  
            "Applicable all units.
			 The minimum interval between two consecutive AU/BU to SU/RB messages.
             Range: 1 to 3600 (Sec)."
            ::= { brzaccVLAdaptiveModulationParams 4 }

    brzaccVLAdaptiveModulationDecisionThresholds OBJECT-TYPE
            SYNTAX  INTEGER  { normal (1) , high (2), na (255) }
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to all units. 
             Defines the setting of thresholds for the rate decision algorithm. 
             high (2) should typically be used when the SNR is lower than 13dB."
            ::= { brzaccVLAdaptiveModulationParams  5 }

brzaccVLBurstMode     OBJECT IDENTIFIER ::= {brzaccVLPerformanceParams 10}

    brzaccVLBurstModeOption OBJECT-TYPE
            SYNTAX  INTEGER  {   disable (1) , enable (2), blocked(3), na (255) }
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to all units.
             Applicable only if Burst Mode Option is supported by country 
             specific parameters of the Sub Band.  
             Not applicable if Wireless Link Prioritization is enabled.
             Enables/disable burst mode operation.
             In SU/RB with HW Revision B or lower blocked(3) value is returned
             when Security Mode is Wep , Data Encryption Option
			 is Enabled and Burst option is Enabled.
			 In AU/BU with HW Revision B or lower blocked(3) value is returned
			 when Dfs Option is Enabled and Burst mode is enabled."
            ::= { brzaccVLBurstMode  1 }

    brzaccVLBurstInterval OBJECT-TYPE
            SYNTAX  INTEGER
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to all units.
             Not applicable if Wireless Link Prioritization is enabled.
             Burst mode interval in milliseconds.
             Range: 1 to the maximum value as defined in the country 
             specific parameters of the Sub Band (milliseconds)."
            ::= { brzaccVLBurstMode  2 }

brzaccVLConcatenationParameters     OBJECT IDENTIFIER ::= {brzaccVLPerformanceParams 11}
  
   brzaccVLConcatenationOption OBJECT-TYPE
            SYNTAX  INTEGER  { disable (1), enable (2), na (255)}
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to all units. 
             Defines the Concatenation option."
            ::= { brzaccVLConcatenationParameters 1 }

  brzaccVLConcatenationMaximumNumberOfFrames OBJECT-TYPE
            SYNTAX  INTEGER (2..8)
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to all units with SW version 3.X . 
             Not applicable for version 4.0 and higher.
             Defines the maximum numbers of frames that can be concatenated.
             Range:2 to 8 (frames)."
            ::= { brzaccVLConcatenationParameters 2 }
 
   brzaccVLConcatenationMaxFrameSize OBJECT-TYPE
            SYNTAX  INTEGER
            MAX-ACCESS read-write      
            STATUS current       
            DESCRIPTION  
            "Applicable to all units. 
			 Defines the maximum size of a concatenated frame.
			 Range:
			 256 to 2200 (bytes) for BreezeNET-B products BU/RB14 BU/RB28, 
			 or for AU/SU with HW revision A or B.
			 256 to 4032 (bytes) for AU/SU with HW Revision 
			 C or higher and BreezeNET-B products BU/RB100."
            ::= { brzaccVLConcatenationParameters 3 }

                        
-- Site Survey Params
-- ==================
brzaccVLSiteSurvey        OBJECT IDENTIFIER ::= {breezeAccessVLMib 11}

    brzaccVLAverageReceiveSNR  OBJECT-TYPE
            SYNTAX INTEGER
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION 
            "Applicable to SU/RB only. 
             The average Signal to Noise Ratio of received frames."
            ::= { brzaccVLSiteSurvey 1 }

-- Traffic Counters
-- ================
brzaccVLTrafficStatistics	    OBJECT IDENTIFIER ::= {brzaccVLSiteSurvey 2}


    brzaccVLResetTrafficCounters OBJECT-TYPE
	     	SYNTAX	INTEGER { reset (1),cancel(2) }  
		    MAX-ACCESS read-write
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units.
             Resets the traffic counters."
			::= { brzaccVLTrafficStatistics 1 }

brzaccVLEthCounters	         OBJECT IDENTIFIER ::= {brzaccVLTrafficStatistics 2}
brzaccVLWirelessLinkCounters OBJECT IDENTIFIER ::= {brzaccVLTrafficStatistics 3}
brzaccVLWirelessLinkEvents	 OBJECT IDENTIFIER ::= {brzaccVLTrafficStatistics 4}

brzaccVLPerModulationLevelCounters	     OBJECT IDENTIFIER ::= {brzaccVLTrafficStatistics 5}


	brzaccVLResetPerModulationLevelCounters OBJECT-TYPE
	     	SYNTAX	INTEGER { resetCounters(1) , cancel (2) } 
		    MAX-ACCESS read-write
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units.
             Resets the per-Modulation Level counters ." 
			::= { brzaccVLPerModulationLevelCounters 1 }



    brzaccVLSUPerModulationLevelCountersTable OBJECT-TYPE
            SYNTAX SEQUENCE OF BrzaccVLSUPerModulationLevelCountersEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to SU/RB. 
             Per Rate Counters table." 
            ::= { brzaccVLPerModulationLevelCounters 2 }

    brzaccVLSUPerModulationLevelCountersEntry  OBJECT-TYPE
            SYNTAX BrzaccVLSUPerModulationLevelCountersEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
            "Applicable to SU/RB. 
             An entry in the Per modulation  Counters table." 
            INDEX { brzaccVLSUPerModulationLevelCountersTableIdx }
            ::= { brzaccVLSUPerModulationLevelCountersTable 1 }

    BrzaccVLSUPerModulationLevelCountersEntry ::= SEQUENCE {
            brzaccVLSUPerModulationLevelCountersTableIdx       INTEGER,
            brzaccVLSUPerModulationLevelCountersApplicableModLevel INTEGER,
            brzaccVLSUPerModulationLevelCountersTxSuccess      Counter32,
            brzaccVLSUPerModulationLevelCountersTxFailed   Counter32
            }

         
    brzaccVLSUPerModulationLevelCountersTableIdx   OBJECT-TYPE
            SYNTAX  INTEGER  (1..8)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB.
             An index of an entry in the Per modulation level Counters table." 
        ::= { brzaccVLSUPerModulationLevelCountersEntry 1 }

    brzaccVLSUPerModulationLevelCountersApplicableModLevel   OBJECT-TYPE
            SYNTAX  INTEGER    { 
            					 modLevel-1  (1), 
							     modLevel-2  (2), 
							     modLevel-3  (3), 
							     modLevel-4  (4), 
							     modLevel-5  (5), 
							     modLevel-6  (6), 
							     modLevel-7  (7), 
							     modLevel-8  (8) 
							   } 
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB.
             The applicable modulation level of the entry in the Per 
             modulation level Counters table.
             Modulation Level 8 is not applicable for units with HW revision A." 
        ::= { brzaccVLSUPerModulationLevelCountersEntry 2 }


    brzaccVLSUPerModulationLevelCountersTxSuccess      OBJECT-TYPE
            SYNTAX  Counter32  
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB.
             The total number of successfully transmitted unicasts at the 
             applicable modulation level." 
        ::= { brzaccVLSUPerModulationLevelCountersEntry 3 }


    brzaccVLSUPerModulationLevelCountersTxFailed   OBJECT-TYPE
            SYNTAX  Counter32  
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION  
            "Applicable to SU/RB.
             The total number of dropped frames at the applicable 
             Modulation Level." 
        ::= { brzaccVLSUPerModulationLevelCountersEntry 4 }


   brzaccVLAverageModulationLevel	 OBJECT-TYPE
	        SYNTAX INTEGER 
	        MAX-ACCESS read-only
	        STATUS current
	        DESCRIPTION	
	        "Applicable to SU/RB. 
	         The average modulation level for successful transmission 
	         (rounded to nearest integer) since last reset of the 
	         Per Modulation Level counters. 
	         Range: 1 to 8."  
	        ::= { brzaccVLPerModulationLevelCounters 3 }

    brzaccVLTotalRxFramesViaEthernet OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             Total number of frames received via the Ethernet port."
			::= { brzaccVLEthCounters 1 }

    brzaccVLTxWirelessToEthernet OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             Total number of frames transmitted to the Ethernet port."
			::= { brzaccVLEthCounters 2 }

brzaccVLTxFramesToWireless	 OBJECT IDENTIFIER ::= {brzaccVLWirelessLinkCounters 1}

    brzaccVLAUBeaconsToWireless OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to AU/BU only.
             The number of beacons transmitted to the wireless media."
			::= { brzaccVLTxFramesToWireless 1 }

--    brzaccVLOtherMngFramesToWireless OBJECT-TYPE
--      		SYNTAX  Counter32
--		    MAX-ACCESS read-only
--	     	STATUS current
--		    DESCRIPTION	 
--            "Applicable to AU and SU.
--             The number of management frames transmitted to the wireless media.
--             In AU, this count does not include Beacons."
--			::= { brzaccVLTxFramesToWireless 2 }

    brzaccVLDataAndOtherMngFramesToWireless OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to AU/BU only.
             The number of data and management frames transmitted to the 
             wireless media. The count includes one count for each data 
             frame transmitted successfully (excluding retransmissions)."
			::= { brzaccVLTxFramesToWireless 3 }

    brzaccVLTotalTxFramesToWireless OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The number of frames transmitted to the wireless media.
             The count includes one count for each data frame
             that was transmitted successfully (excluding retransmissions),
             and also the number of transmitted control and management frames, 
             including beacons."
			::= { brzaccVLTxFramesToWireless 4 }
   
    brzaccVLTotalTransmittedUnicasts OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to AU/BU only.	 
             The total number of unicast frames successfully transmitted 
             to the wireless media, excluding retransmissions."
			::= { brzaccVLTxFramesToWireless 5 }

    brzaccVLTotalTransmittedConcatenatedFramesDouble OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all products.	 
             The total number of double concatenated frames successfully transmitted 
             to the wireless media, excluding retransmissions."
			::= { brzaccVLTxFramesToWireless 6 }

    brzaccVLTotalTransmittedConcatenatedFramesSingle OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all products.	 
             The total number of double concatenated frames successfully transmitted 
             to the wireless media, excluding retransmissions."
			::= { brzaccVLTxFramesToWireless 7 }

    brzaccVLTotalTransmittedConcatenatedFramesMore OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all products.	 
             The total number of concatenated frames with more then two frames successfully 
             transmitted to the wireless media, excluding retransmissions."
			::= { brzaccVLTxFramesToWireless 8 }
			
    brzaccVLTotalRxFramesFromWireless OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The total number of frames that were received
             from the wireless media.
             The count includes data and control and management
             frames, including beacons received from the AU/BU.
             The count does not include frames that were discarded
             internally, bad frames and duplicate frames."
			::= { brzaccVLWirelessLinkCounters 2 }

    brzaccVLTotalRetransmittedFrames OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The total number of retransmissions of data frames 
             (counts all unsuccessful transmissions/retransmissions)."
			::= { brzaccVLWirelessLinkCounters 3 }

    brzaccVLFramesDropped OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The number of dropped frames.
             The frames that were retransmitted to the extent
             of the maximum allowed number of retransmissions
             without being acknowledged.."
			::= { brzaccVLWirelessLinkCounters 4 }


brzaccVLDataFramesSubmittedToBridge	 OBJECT IDENTIFIER ::= {brzaccVLWirelessLinkCounters 5}

	brzaccVLFramesSubmittedViaHighQueue OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             Frames submitted to the internal bridge via the High priority queue. 
             for transmission to the wireless media."
			::= { brzaccVLDataFramesSubmittedToBridge 1 }

	brzaccVLFramesSubmittedViaMidQueue OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             Frames submitted to the internal bridge via the Mid priority queue 
             for transmission to the wireless media."
			::= { brzaccVLDataFramesSubmittedToBridge 2 }

	brzaccVLFramesSubmittedViaLowQueue OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             Frames submitted to the internal bridge via the Low priority queue 
             for transmission to the wireless media."
			::= { brzaccVLDataFramesSubmittedToBridge 3 }

	brzaccVLTotalNoOfDataFramesSubmitted OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The total number of data frames submitted to the internal bridge 
             for transmission to the wireless media."
			::= { brzaccVLDataFramesSubmittedToBridge 4 }


    brzaccVLTotalRecievedDataFrames OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The total number of data frames received from the
             wireless media, including duplicate frames."
			::= { brzaccVLWirelessLinkCounters 6 }

    brzaccVLRecievedBadFrames OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The number of frames received from the wireless
             media with errors (CRC errors)."
			::= { brzaccVLWirelessLinkCounters 7 }

    brzaccVLNoOfDuplicateFramesDiscarded OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The number of frames discarded due to receiving multiple copies."
			::= { brzaccVLWirelessLinkCounters 8 }

    brzaccVLNoOfInternallyDiscardedMirCir OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
            The number of data frames received from the Ethernet port that were 
            discarded by the MIR/CIR mechanism either to avoid exceeding the 
            maximum allowed information rate, or when the wireless link conditions 
            do not enable reaching the allowed rate."
			::= { brzaccVLWirelessLinkCounters 9 }

    brzaccVLTotalRxConcatenatedFramesDouble OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units.
            The total number of double concatenated frames received 
            from the wireless media, including duplicate frames."
			::= { brzaccVLWirelessLinkCounters 10 }

    brzaccVLTotalRxConcatenatedFramesSingle OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The total number of data fast frames single concatenated 
             frames received from the wireless media, including duplicate frames."
			::= { brzaccVLWirelessLinkCounters 11 }

    brzaccVLTotalRxConcatenatedFramesMore OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The total number of data fast frames concatenated with more then two 
             frames received from the wireless media, including duplicate frames."
			::= { brzaccVLWirelessLinkCounters 12 }
					
--	brzaccVLInternallyGeneratedFramesSubmittedToBridge OBJECT-TYPE
--      		SYNTAX  Counter32
--		    MAX-ACCESS read-only
--	     	STATUS current
--		    DESCRIPTION	 
--            "Applicable to SU and AU. Read-only.
--             The number of internally generated frames(wireless management and control frames)
--             submitted to the bridge for transmission to the wireless media."
--			::= { brzaccVLWirelessLinkCounters 10 }


brzaccVLTxEvents	 OBJECT IDENTIFIER ::= {brzaccVLWirelessLinkEvents 1}

    brzaccVLDroppedFrameEvents OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
			 The number of frames that were dropped because they were retransmitted
			 to the maximum allowed number of retransmissions without being 
			 acknowledged."
			::= { brzaccVLTxEvents 1 }

    brzaccVLFramesDelayedDueToSwRetry OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             Not applicable for units with SW Version 3.0 and higher.
             The number of frames that were delayed because the SW retry 
             algorithm was activated on a previous frame designated for the 
             same recipient."
			::= { brzaccVLTxEvents 2 }

    brzaccVLUnderrunEvents OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The number of frames whose transmission was aborted because the rate
             of submitting frames for transmission exceeded the available 
             transmission capability."
			::= { brzaccVLTxEvents 3 }

    brzaccVLOthersTxEvents  OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The number of Tx events due to problems other than those of 
             the other Tx Events counters."
			::= { brzaccVLTxEvents 4 }

    brzaccVLTotalTxEvents OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The total number of Tx special events."
			::= { brzaccVLTxEvents 5 }

brzaccVLRxEvents	 OBJECT IDENTIFIER ::= {brzaccVLWirelessLinkEvents 2}

    brzaccVLPhyErrors OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units, only when DFS is enabled. 
             The number of unidentified signals."
			::= { brzaccVLRxEvents 1 }

    brzaccVLCRCErrors OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The number of frames received from the wireless media containing 
             CRC errors."
			::= { brzaccVLRxEvents 2 }

    brzaccVLOverrunEvents OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The number of frames that were discarded because the receive 
             rate exceeded the processing capability or the capacity of the 
             Ethernet port."
			::= { brzaccVLRxEvents 3 }

    brzaccVLRxDecryptEvents OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The number of frames that were not received properly due to a 
             problem in the data decryption mechanism."
			::= { brzaccVLRxEvents 4 }

    brzaccVLTotalRxEvents OBJECT-TYPE
      		SYNTAX  Counter32
		    MAX-ACCESS read-only
	     	STATUS current
		    DESCRIPTION	 
            "Applicable to all units. 
             The total number of Rx special events."
			::= { brzaccVLRxEvents 5 }


-- Associations Database
-- 
brzaccVLMacAddressDatabase   OBJECT IDENTIFIER ::= {brzaccVLSiteSurvey 5}

brzaccVLAUMacAddressDatabase   OBJECT IDENTIFIER ::= {brzaccVLMacAddressDatabase 1}

brzaccVLAUAdbResetAllModulationLevelCounters OBJECT-TYPE
	  SYNTAX  INTEGER { reset (1), cancel (2) }  
      MAX-ACCESS  read-write    
      STATUS  current
      DESCRIPTION
      "Applicable to AU/BU only. 
	   To reset all the counters for all SUs/RB in the MAC Address Database."
      ::= { brzaccVLAUMacAddressDatabase 1 }

brzaccVLAUAdbTable OBJECT-TYPE
	  SYNTAX SEQUENCE OF BrzaccVLAUAdbEntry
	  MAX-ACCESS not-accessible
	  STATUS current
	  DESCRIPTION
      "Applicable to AU/BU only. 
       AU/BU MAC Address Database table."
	  ::= { brzaccVLAUMacAddressDatabase 2 }

brzaccVLAUAdbEntry  OBJECT-TYPE
	  SYNTAX BrzaccVLAUAdbEntry
	  MAX-ACCESS not-accessible
	  STATUS current
      DESCRIPTION
      "Applicable to AU/BU only. 
       An entry in the AU/BU MAC Address Database table."
	  INDEX { brzaccVLAdbIndex }
	  ::= { brzaccVLAUAdbTable 1 }

			   
BrzaccVLAUAdbEntry ::= SEQUENCE {
 	  brzaccVLAdbIndex			    INTEGER,
 	  brzaccVLAdbMacAddress		    MacAddress,
	  brzaccVLAdbStatus			    INTEGER,
	  brzaccVLAdbSwVersion			DisplayString,
	  brzaccVLAdbSNR                INTEGER,
 	  brzaccVLAdbMaxModulationLevel INTEGER,
	  brzaccVLAdbTxFramesTotal	    Counter32,
	  brzaccVLAdbDroppedFramesTotal	Counter32,
	  brzaccVLAdbTxSuccessModLevel1	Counter32,
	  brzaccVLAdbTxSuccessModLevel2	Counter32,
	  brzaccVLAdbTxSuccessModLevel3	Counter32,
	  brzaccVLAdbTxSuccessModLevel4	Counter32,
	  brzaccVLAdbTxSuccessModLevel5	Counter32,
	  brzaccVLAdbTxSuccessModLevel6	Counter32,
	  brzaccVLAdbTxSuccessModLevel7	Counter32,
	  brzaccVLAdbTxSuccessModLevel8	Counter32,
	  brzaccVLAdbTxFailedModLevel1	Counter32,
	  brzaccVLAdbTxFailedModLevel2	Counter32,
	  brzaccVLAdbTxFailedModLevel3	Counter32,
	  brzaccVLAdbTxFailedModLevel4	Counter32,
	  brzaccVLAdbTxFailedModLevel5	Counter32,
	  brzaccVLAdbTxFailedModLevel6	Counter32,
	  brzaccVLAdbTxFailedModLevel7	Counter32,
	  brzaccVLAdbTxFailedModLevel8	Counter32,
   	  brzaccVLAdbCirTx              INTEGER,
      brzaccVLAdbMirTx              INTEGER,
      brzaccVLAdbCirRx              INTEGER,
      brzaccVLAdbMirRx              INTEGER,
      brzaccVLAdbCirMaxDelay        INTEGER,
	  brzaccVLAdbDistance			INTEGER,
	  brzaccVLAdbHwRevision			INTEGER,
	  brzaccVLAdbCpldVer			DisplayString,
	  brzaccVLAdbCountryCode    	INTEGER,
	  brzaccVLAdbBootVer			DisplayString,
	  brzaccVLAdbAtpcOption			INTEGER,
	  brzaccVLAdbAdapModOption		INTEGER,
	  brzaccVLAdbBurstModeOption	INTEGER,
	  brzaccVLAdbConcatenationOption	INTEGER,
	  brzaccVLAdbSecurityMode		INTEGER,
	  brzaccVLAdbAuthOption			INTEGER,
	  brzaccVLAdbDataEncyptOption	INTEGER,
	  brzaccVLAdbAge                INTEGER,
	  brzaccVLAdbUnitName           DisplayString
	  }

brzaccVLAdbIndex OBJECT-TYPE
	  SYNTAX INTEGER  (1..512)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   The index of an entry in the AU/BU MAC Address Database table."
	  ::= { brzaccVLAUAdbEntry 1 }

brzaccVLAdbMacAddress  OBJECT-TYPE
	  SYNTAX MacAddress  
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
      "Applicable to AU/BU only. 
	   The MAC Address of an SU/RB entry in the MAC Address Database 
	   table."
	  ::= { brzaccVLAUAdbEntry 2 }

brzaccVLAdbStatus	 OBJECT-TYPE
	  SYNTAX INTEGER { associated       (1), 
	                   authenticated    (2),
	                   notAuthenticated (3) }
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   The status of the relevant SU/RB."
	  ::= { brzaccVLAUAdbEntry 3 }

brzaccVLAdbSwVersion OBJECT-TYPE
	  SYNTAX DisplayString  
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   The SW version of the relevant SU/RB."
	  ::= { brzaccVLAUAdbEntry 4 }

brzaccVLAdbSNR	OBJECT-TYPE
	  SYNTAX INTEGER  
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   The average Signal to Noise Ratio in dB of frames received by 
	   the AU/BU from the relevant SU/RB."
	  ::= { brzaccVLAUAdbEntry 5 }

brzaccVLAdbMaxModulationLevel  OBJECT-TYPE
	  SYNTAX INTEGER  { modLevel-1 (1), 
	                    modLevel-2 (2), 
                        modLevel-3 (3), 
                        modLevel-4 (4), 
                        modLevel-5 (5), 
                        modLevel-6 (6), 
                        modLevel-7 (7), 
                        modLevel-8 (8) 
                      }  
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   The value configured in the relevant SU/RB for the Maximum Modulation 
	   Level parameter.
	   Modulation Level 8 is not applicable for units with HW revision A."
	  ::= { brzaccVLAUAdbEntry 6 }

brzaccVLAdbTxFramesTotal	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of unicast  frames (excluding retransmissions) 
	   that were successfully transmitted to the SU/RB over the wireless link."
	  ::= { brzaccVLAUAdbEntry 7 }

brzaccVLAdbDroppedFramesTotal  OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of frames intended to the SU/RB that 
	   were dropped because they were retransmitted to the extent 
	   of the maximum allowed number of retransmissions without 
	   being acknowledged."
	  ::= { brzaccVLAUAdbEntry 8 }

brzaccVLAdbTxSuccessModLevel1	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of unicast frames (excluding retransmissions) 
	   that were successfully transmitted to the SU/RB over the wireless link 
	   using modulation level 1."
	  ::= { brzaccVLAUAdbEntry 9 }

brzaccVLAdbTxSuccessModLevel2	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of unicast frames (excluding retransmissions) 
	   that were successfully transmitted to the SU/RB over the wireless link 
	   using modulation level 2."
	  ::= { brzaccVLAUAdbEntry 10 }

brzaccVLAdbTxSuccessModLevel3	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of unicast frames (excluding retransmissions) 
	   that were successfully transmitted to the SU/BU over the wireless link 
	   using modulation level 3."
	  ::= { brzaccVLAUAdbEntry 11 }

brzaccVLAdbTxSuccessModLevel4	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of unicast frames (excluding retransmissions) 
	   that were successfully transmitted to the SU/RB over the wireless link 
	   using modulation level 4."
	  ::= { brzaccVLAUAdbEntry 12 }

brzaccVLAdbTxSuccessModLevel5	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of unicast frames (excluding retransmissions) 
	   that were successfully transmitted to the SU/RB over the wireless link 
	   using modulation level 5."
	  ::= { brzaccVLAUAdbEntry 13 }

brzaccVLAdbTxSuccessModLevel6	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of unicast frames (excluding retransmissions) 
	   that were successfully transmitted to the SU/BU over the wireless link 
	   using modulation level 6."
	  ::= { brzaccVLAUAdbEntry 14 }

brzaccVLAdbTxSuccessModLevel7	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of unicast frames (excluding retransmissions) 
	   that were successfully transmitted to the SU/RB over the wireless link 
	   using modulation level 7."
	  ::= { brzaccVLAUAdbEntry 15 }

brzaccVLAdbTxSuccessModLevel8	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of unicast frames (excluding retransmissions) 
	   that were successfully transmitted to the SU/RB over the wireless link 
	   using modulation level 8.
	   Not applicable for units with HW revision A."
	  ::= { brzaccVLAUAdbEntry 16 }

brzaccVLAdbTxFailedModLevel1	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of failures to successfully
	   transmit unicast frames intended to the SU/RB using modulation level 1."
	  ::= { brzaccVLAUAdbEntry 17 }

brzaccVLAdbTxFailedModLevel2	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of failures to successfully
	   transmit unicast frames intended to the SU/RB using modulation level 2."
	  ::= { brzaccVLAUAdbEntry 18 }

brzaccVLAdbTxFailedModLevel3	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of failures to successfully
	   transmit unicast frames intended to the SU/RB using modulation level 3."
	  ::= { brzaccVLAUAdbEntry 19 }

brzaccVLAdbTxFailedModLevel4	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of failures to successfully
	   transmit unicast frames intended to the SU/RB using modulation level 4."
	  ::= { brzaccVLAUAdbEntry 20 }

brzaccVLAdbTxFailedModLevel5	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of failures to successfully
	   transmit unicast frames intended to the SU/RB using modulation level 5."
	  ::= { brzaccVLAUAdbEntry 21 }

brzaccVLAdbTxFailedModLevel6	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of failures to successfully
	   transmit unicast frames intended to the SU/RB using modulation level 6."
	  ::= { brzaccVLAUAdbEntry 22 }

brzaccVLAdbTxFailedModLevel7	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of failures to successfully
	   transmit unicast frames intended to the SU/RB using modulation level 7."
	  ::= { brzaccVLAUAdbEntry 23 }

brzaccVLAdbTxFailedModLevel8	OBJECT-TYPE
	  SYNTAX Counter32 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   Counts the total number of failures to successfully
	   transmit unicast frames intended to the SU/RB using modulation level 8.
	   Not applicable for units with HW revision A."
	  ::= { brzaccVLAUAdbEntry 24 }

brzaccVLAdbCirTx  OBJECT-TYPE
   SYNTAX INTEGER 
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU Only. 
    Not applicable to BreezeNET-B products. Read-only. 
    The value configured in the relevant SU for the CIR: 
    SU to AU parameter."
   ::= { brzaccVLAUAdbEntry 25 }

brzaccVLAdbMirTx  OBJECT-TYPE
   SYNTAX INTEGER 
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU/BU only. 
    The value configured in the relevant SU/RB for the MIR: 
    SU/RB to AU/BU parameter."
   ::= { brzaccVLAUAdbEntry 26 }

brzaccVLAdbCirRx  OBJECT-TYPE
   SYNTAX INTEGER 
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU Only.
    Not applicable to BreezeNET-B products.
    The value configured in the relevant SU for the CIR: 
    AU to SU parameter."
   ::= { brzaccVLAUAdbEntry 27 }

brzaccVLAdbMirRx  OBJECT-TYPE
   SYNTAX INTEGER 
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU/BU only. 
    The value configured in the relevant SU/RB for the MIR: 
    AU/BU to SU/RB parameter."
   ::= { brzaccVLAUAdbEntry 28 }

brzaccVLAdbCirMaxDelay   OBJECT-TYPE
   SYNTAX INTEGER 
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU Only. 
    Not applicable to BreezeNET-B products.
    The value configured in the relevant SU for the CIR Maximum 
    Delay parameter."
   ::= { brzaccVLAUAdbEntry 29 }

brzaccVLAdbDistance     OBJECT-TYPE
   SYNTAX INTEGER  {below-2-Km(1)}
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU/BU Only.  
    The distance between the SU/RB and the AU/BU (In Kilometers)."
   ::= { brzaccVLAUAdbEntry 30 }

brzaccVLAdbHwRevision     OBJECT-TYPE
   SYNTAX INTEGER  {hwRevisionA(1), hwRevisionB(2), hwRevisionC(3), 
                    hwRevisionD(4), hwRevisionE(5), na(255)}
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU/BU Only.  
    The SU/RB HW Revision."
   ::= { brzaccVLAUAdbEntry 31 }

brzaccVLAdbCpldVer     OBJECT-TYPE
   SYNTAX DisplayString
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU/BU Only.  
    The SU/RB CPLD Version."
   ::= { brzaccVLAUAdbEntry 32 }

brzaccVLAdbCountryCode     OBJECT-TYPE
   SYNTAX INTEGER  
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU/BU Only.  
    The SU/RB supported country code."
   ::= { brzaccVLAUAdbEntry 33 }

brzaccVLAdbBootVer     OBJECT-TYPE
   SYNTAX DisplayString
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU/BU Only.  
    The SU/RB Boot Version."
   ::= { brzaccVLAUAdbEntry 34 }

brzaccVLAdbAtpcOption     OBJECT-TYPE
   SYNTAX INTEGER  {disable (1), enable (2), na (255)}
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU/BU Only.  
    The SU/RB ATPC option configuration."
   ::= { brzaccVLAUAdbEntry 35 }

brzaccVLAdbAdapModOption     OBJECT-TYPE
   SYNTAX INTEGER  {disable (1), enable (2), na (255)}
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU/BU Only.  
    The SU/RB adaptive modulation option configuration."
   ::= { brzaccVLAUAdbEntry 36 }

brzaccVLAdbBurstModeOption     OBJECT-TYPE
   SYNTAX INTEGER  {disable (1), enable (2), na (255)}
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU/BU Only.  
    The SU/RB burst mode option configuration."
   ::= { brzaccVLAUAdbEntry 37 }

brzaccVLAdbConcatenationOption     OBJECT-TYPE
   SYNTAX INTEGER  {disable (1), enable (2), na(255)}
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU/BU Only.  
    The SU/RB concatenation option configuration."
   ::= { brzaccVLAUAdbEntry 39 }

brzaccVLAdbSecurityMode     OBJECT-TYPE
   SYNTAX INTEGER  {wep(1), aes(2), fips197(3), na(255)}
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU/BU Only.  
    The SU/RB security mode configuration."
   ::= { brzaccVLAUAdbEntry 41 }

brzaccVLAdbAuthOption     OBJECT-TYPE
   SYNTAX INTEGER  {openSystem (1), sharedKey (2), na (255)}
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU/BU Only.  
    The SU/RB authentication algorithm configuration."
   ::= { brzaccVLAUAdbEntry 42 }

brzaccVLAdbDataEncyptOption     OBJECT-TYPE
   SYNTAX INTEGER  {disable (1), enable (2), na (255)}
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION 
   "Applicable to AU/BU Only.  
    The SU/RB data encryption option configuration."
   ::= { brzaccVLAUAdbEntry 43 }

brzaccVLAdbAge	OBJECT-TYPE
	  SYNTAX INTEGER  
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   The time since any packet was received from the relevant SU/RB."
	  ::= { brzaccVLAUAdbEntry 44 }
	  
brzaccVLAdbUnitName	OBJECT-TYPE
	  SYNTAX DisplayString 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
      "Applicable to AU/BU only. 
	   The unit name of the relevant SU/RB."
	  ::= { brzaccVLAUAdbEntry 45 }


brzaccVLUpLinkQualityIndicator  OBJECT IDENTIFIER ::= { brzaccVLSiteSurvey 6}

brzaccVLMeasureUpLinkQualityIndicator	 OBJECT-TYPE
	  SYNTAX INTEGER { start (1) , cancel (2)}
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION	
	  "Applicable to SU/RB. 
	   Starts calculation of LQI. 
	   The calculation will be for a period of 10 seconds."  
	  ::= { brzaccVLUpLinkQualityIndicator 1 }


brzaccVLReadUpLinkQualityIndicator	 OBJECT-TYPE
	  SYNTAX INTEGER 
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
	  "Applicable to SU/RB. 
	   The results of the last LQI calculation. 
	   Range: 1 to 8."  
	  ::= { brzaccVLUpLinkQualityIndicator 2 }
 

brzaccVLUpLinkQualityIndicatorStatus	 OBJECT-TYPE
	  SYNTAX INTEGER  {fullTest(1) , limitedTest(2)}
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION	
	  "Applicable to SU/RB Only. 
	   Indicates the test conditions. 
	   fullTest means that there are no limitations 
	   on the range of available modulation levels, and that all modulation levels 
	   from 1 to 8 can be used. 
	   limitedTest indicates that the results may not indicate the true quality since 
	   the available range is limited - by HW (HW Revision A), 
	   or by the applicable parameters in the country code, 
	   or by the configurable Maximum Modulation Level parameter."  
	  ::= { brzaccVLUpLinkQualityIndicator 3 }
	  
-- AC pinpoint table end
	  
brzaccVLMacPinpoint   OBJECT IDENTIFIER ::= {brzaccVLSiteSurvey 7}

          brzaccVLMacPinpointTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF BrzaccVLMacPinpointEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "Applicable to AU/BU only.
                      A table that contains information about wireless device
                      used by a certain Ethernet station in order to
                      connect to the wireless network"
              ::= { brzaccVLMacPinpoint 1 }

          brzaccVLMacPinpointEntry OBJECT-TYPE
              SYNTAX  BrzaccVLMacPinpointEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "Applicable to AU/BU only. An entry in the MAC Pinpoint Table.
                      Each entry contains an Ethernet station MAC address and the MAC
                      address of the wireless device used to connect it to the wireless 
                      network"
              INDEX   { mptEthernetStationMACAddress }
              ::= { brzaccVLMacPinpointTable 1 }

          BrzaccVLMacPinpointEntry ::=
              SEQUENCE {
                  mptEthernetStationMACAddress
                      MacAddress,
                  mptUnitMACAddress
                      MacAddress
              }

          mptEthernetStationMACAddress OBJECT-TYPE
              SYNTAX  MacAddress
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "Applicable to AU/BU only.
                      The MAC address of the Ethernet station. It is used as an 
                      index in the MAC Pinpoint Table."
              ::= { brzaccVLMacPinpointEntry 1 }
              
          mptUnitMACAddress OBJECT-TYPE
              SYNTAX  MacAddress
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "Applicable to AU/BU only. The MAC address of the wireless 
                      device used by the station with the MAC Address from the 
                      index in order to access the wireless network."
              ::= { brzaccVLMacPinpointEntry 2 }
-- AC pinpoint table end

-- GATEWAY TABLE BEGIN

brzaccVLDrapGatewaysTable OBJECT-TYPE
        SYNTAX SEQUENCE OF BrzaccVLDrapGatewayEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
		"This table provides information about Gateways supporting DRAP that are
		registered at the AU"
        ::= { brzaccVLSiteSurvey 8 }

brzaccVLDrapGatewayEntry  OBJECT-TYPE
        SYNTAX BrzaccVLDrapGatewayEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
        "A Drap Gateway Entry." 
        INDEX { brzaccVLDrapGatewayIndex }
        ::= { brzaccVLDrapGatewaysTable 1 }

BrzaccVLDrapGatewayEntry ::= SEQUENCE {
		brzaccVLDrapGatewayIndex					INTEGER,
		brzaccVLDrapGatewayIP 					    IpAddress,
       	brzaccVLDrapGatewayType					    INTEGER,
        brzaccVLDrapGatewayNoOfActiveVoiceCalls		INTEGER
        }
            
brzaccVLDrapGatewayIndex OBJECT-TYPE
        SYNTAX INTEGER	(1..512)  
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION 
        "Gateway Entry's Index"
        ::= { brzaccVLDrapGatewayEntry 1 }
        
brzaccVLDrapGatewayIP OBJECT-TYPE
        SYNTAX IpAddress  
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION 
        "The IP address of the Gateway"
        ::= { brzaccVLDrapGatewayEntry 2 }

brzaccVLDrapGatewayType OBJECT-TYPE
        SYNTAX INTEGER  { vgDataVoice (4), vgData1Voice1 (5), 
                          vgData4Voice2 (6), vgDataVoice2(7), 
                          ngData4Wireless (11),
                          vgUnknown(255)
                         }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION 
        "The Gateway type"
        ::= { brzaccVLDrapGatewayEntry 3 }

brzaccVLDrapGatewayNoOfActiveVoiceCalls OBJECT-TYPE
        SYNTAX INTEGER  
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION 
        "The current number of active voice calls handled by the Gateway"
        ::= { brzaccVLDrapGatewayEntry 4 }

-- GATEWAY TABLE END 

-- ****************************************************************************************
--  TRAP defenitions: 
-- ****************************************************************************************

brzaccVLTraps OBJECT IDENTIFIER ::= { breezeAccessVLMib 14 }

brzaccVLTrapSUMacAddr OBJECT-TYPE
    SYNTAX  MacAddress
    MAX-ACCESS  read-only  
    STATUS current
    DESCRIPTION
    "Applicable to AU/BU only.
     SU/RB MAC Address."
    ::= { brzaccVLTraps 1 }

--brzaccVLTrapSNRQuality   OBJECT-TYPE
--    SYNTAX INTEGER
--    MAX-ACCESS read-only  
--    STATUS current
--    DESCRIPTION
--    "Applicable to SU only.
--     SNR of received signal."
--    ::= { brzaccVLTraps 2 }

brzaccVLTrapText  OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "Textual string for future use."
    ::= { brzaccVLTraps 3 }

brzaccVLTrapToggle    OBJECT-TYPE
    SYNTAX INTEGER{
        on (1),
        off (2)
        }
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "Applicable to all units.
     An On/Off toggle status." 
    ::= { brzaccVLTraps 4 }

brzaccVLTrapParameterChanged  OBJECT-TYPE
    SYNTAX INTEGER{ cirOrMir (1),
                    ipFilter (2), 
                    vlan (4)}
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "Applicable to all units.
     A modification to one of the parameters related to CIR/MIR,  
     IP Filtering or VLAN."
    ::= { brzaccVLTraps 5 }

brzaccVLTrapAccessRights  OBJECT-TYPE
    SYNTAX INTEGER{ notLoggedIn   (1), 
                    readOnly      (2), 
                    installer     (3), 
                    administrator (4),  
                    factory       (5) }
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "Applicable to all units.
     The access rights used for login."
    ::= { brzaccVLTraps 6 }

brzaccVLTrapLog   OBJECT-TYPE
    SYNTAX INTEGER{ telnetLogin  (3), 
                    telnetLogout (4) }
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "Applicable to all units.
     Login or logout to the Monitor program via Telnet."
    ::= { brzaccVLTraps 7 }

brzaccVLTrapTelnetUserIpAddress   OBJECT-TYPE
    SYNTAX  IpAddress  
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "Applicable to all units.
     The IP address of a Telnet user."
    ::= { brzaccVLTraps 8 }

brzaccVLTrapRTx   OBJECT-TYPE
    SYNTAX INTEGER
    MAX-ACCESS read-only  
    STATUS current
    DESCRIPTION
    "Applicable to AU/BU only. 
     Retransmissions as a percentage of total transmissions."
    ::= { brzaccVLTraps 9 }

brzaccVLTrapFtpOrTftpStatus    OBJECT-TYPE
    SYNTAX INTEGER{
        successful (1),
        failed (2)
        }
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "Applicable to all units.
     The status of the last FTP/TFTP loading procedure." 
    ::= { brzaccVLTraps 10 }
 
brzaccVLDFSMoveFreq    OBJECT-TYPE
    SYNTAX INTEGER
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "Applicable to AU/BU with HW revision B and lower 
     (for units with HW revision C and higher replaced by 
     brzaccVLTrapDFSMoveFreq New to support a resolution of 0.5 MHz). 
     The new frequency in MHz after detecting radar on a previous channel."    
    ::= { brzaccVLTraps 11 }
 
brzaccVLDFSMoveFreqNew    OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "Applicable to AU/BU. 
     The new frequency in MHz after detecting radar on a previous channel. 
     (Replaces brzaccVLDFSMoveFreq to support a resolution of 0.5 MHz for 
     units with HW revision C and higher)."
    ::= { brzaccVLTraps 12 }

    
brzaccVLEthBroadcastThresholdExceeded    OBJECT-TYPE
    SYNTAX INTEGER
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "Applicable to all units. 
    The number of packets that are dropped by the ethernet broadcast/multicast limiter."
    ::= { brzaccVLTraps 13 }
 
 
brzaccVLTrapSubscriberType    OBJECT-TYPE
    SYNTAX INTEGER{ unknownSubscriberType(0), 
                    su-3(3)  , su-6(6)  , rb-14(14), 
                    su-24(24), rb-28(28), su-54(54), 
                    rb-100(100) }
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "Applicable to AUS only.
    The type of subscriber that was rejected by AUS" 
    ::= { brzaccVLTraps 14 }


brzaccVLTrapMACAddress   OBJECT-TYPE
    SYNTAX MacAddress
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "Applicable to BU/RB only.
    The MAC address of the BNET B unit whose type has been changed" 
    ::= { brzaccVLTraps 15 }
    
brzaccVLNewUnitTypeTrap  OBJECT-TYPE
    SYNTAX INTEGER { bu(1), rb(2) }
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "Applicable to BU/RB only.
    The new type of the BNET B unit." 
    ::= { brzaccVLTraps 16 }
    
brzaccVLTrapSWVersion  OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "The SW version of the SU that tries to associate 
    with a station that has Wireless Link Prioritization Enabled"
    ::= { brzaccVLTraps 17 }    
            
--
-- Private Traps for BreezeAccessVL
--

brzaccVLSUassociatedAUTRAP NOTIFICATION-TYPE
        OBJECTS
        {
           brzaccVLTrapSUMacAddr     -- SU MAC address
        }
        STATUS current
        DESCRIPTION
        "An AU/BU trap indicating a new association with an SU/RB."
    ::= { brzAccessVLProducts 2 }

brzaccVLAUdisassociatedTRAP NOTIFICATION-TYPE
        OBJECTS
        {
           brzaccVLTrapSUMacAddr      --Unit MAC address
        }
        STATUS current
        DESCRIPTION
        "An AU/BU trap indicating that an SU/RB has been disassociated 
         from the AU.
         The AU/BU decides that an SU/RB has been disassociated from it and remove it
         from the ADB after receiving from another AU/BU a SNAP frame with the SU/RB 
         MAC address.
         The SNAP frame indicating a network topology change where the SU/RB has 
         associated with another AU/BU will be received if both AUs/BUs are 
         connected to the same Ethernet backbone."
    ::= { brzAccessVLProducts 3 }

brzaccVLAUagingTRAP NOTIFICATION-TYPE
        OBJECTS
        {
     	  brzaccVLTrapSUMacAddr  	-- Unit MAC address
        }
        STATUS current
        DESCRIPTION
	    "An AU/BU trap indicating that the unit association was aged out
	     and removed from the Association database following its failure
	     to acknowledge a specified number of consecutive frames."
    ::= { brzAccessVLProducts 4 }

brzaccVLSUassociatedTRAP NOTIFICATION-TYPE
        OBJECTS
        {
--         brzaccVLLastAUMacAddress,          Old AU mac address
           brzaccVLAssociatedAU              -- New AU mac address
--         brzaccVLTrapLastSNRQuality,          Average SNR with old AU
        }
        STATUS current
        DESCRIPTION
        "An SU/RB trap indicating association with an AU/BU. 
         In addition to the MAC address information of the AU/BU, the 
         trap also includes information on the average SNR of frames 
         received from the AU/BU."
    ::= { brzAccessVLProducts 6 }

brzaccVLAUwirelessQualityTRAP NOTIFICATION-TYPE
        OBJECTS
        {
          brzaccVLTrapToggle,
          brzaccVLTrapRTx
        }
        STATUS current
        DESCRIPTION
        "An AU/BU trap, indicating that the quality of the wireless 
         link (retransmissions rate) has changed and dropped below (Off) or increased  
         above (On) a threshold , defined by the *brzaccVLWirelessTrapThreshold. 
         The threshold for AU/BU is a percentage of retransmissions."
    ::= { brzAccessVLProducts 20 }

brzaccVLPowerUpFromReset NOTIFICATION-TYPE
        OBJECTS
        {
           brzaccVLUnitMacAddress    -- Unit MAC address
        }
        STATUS current
        DESCRIPTION
        "An AU/BU trap indicating power up after Reset."
    ::= { brzAccessVLProducts 101 }

brzaccVLTelnetStatusTRAP NOTIFICATION-TYPE
        OBJECTS
        {
          brzaccVLTrapLog,
          brzaccVLTrapAccessRights,
          brzaccVLTrapTelnetUserIpAddress
        }
        STATUS current
        DESCRIPTION
        "Applicable to all units.
         A trap indicating that a log-in or log-out has been performed 
         via Telnet. Includes the log-in access 
         right and the IP address of the PC performing Telnet."
    ::= { brzAccessVLProducts 102 }

brzaccVLParameterChangedTRAP NOTIFICATION-TYPE
        OBJECTS
        {
           brzaccVLTrapParameterChanged
        }
        STATUS current
        DESCRIPTION
        "Applicable to all units. A trap indicating a change in a CIR/MIR, IP Filter 
         or VLAN parameter."
    ::= { brzAccessVLProducts 103 }

brzaccVLLoadingStatusTRAP NOTIFICATION-TYPE
        OBJECTS
        {
          brzaccVLTrapFtpOrTftpStatus,
		  brzaccVLUnitMacAddress
        }
        STATUS current
        DESCRIPTION
        "Applicable to all units.
         A trap indicating that last FTP/TFTP loading process has been 
         finished successfully or failed. "
    ::= { brzAccessVLProducts 104 }

brzaccVLPromiscuousModeTRAP NOTIFICATION-TYPE
        OBJECTS
        {
          brzaccVLTrapToggle,
		  brzaccVLUnitMacAddress
        }
        STATUS current
        DESCRIPTION
        "An AU/BU trap, indicating that the AU/BU In (On) Promiscuous Mode or 
         out (Off) Promiscuous Mode." 
    ::= { brzAccessVLProducts 105 }

brzaccVLDFSRadarDetecetedTRAP NOTIFICATION-TYPE
        STATUS current
        DESCRIPTION
        "DFS: Applicable to AU/BU only.
         A trap indicating that a radar was detected. "
    ::= { brzAccessVLProducts 106 }

brzaccVLDFSFrequcnyTRAP NOTIFICATION-TYPE
        OBJECTS
        {
          brzaccVLDFSMoveFreq, 
          brzaccVLDFSMoveFreqNew        
        }
        STATUS current
        DESCRIPTION
        "Applicable to AU/BU only.
         A trap indicating that the unit moved to a new frequency. "
    ::= { brzAccessVLProducts 107 }

brzaccVLDFSNoFreeChannelsExistsTRAP NOTIFICATION-TYPE
        STATUS current
        DESCRIPTION
        "Applicable to AU/BU only.
         A trap indicating that a radar was detected and there is no 
         free channel. "
    ::= { brzAccessVLProducts 108 }

brzaccVLEthBroadcastMulticatLimiterTRAP NOTIFICATION-TYPE
        OBJECTS
        {
			brzaccVLEthBroadcastThresholdExceeded
		}
        STATUS current
        DESCRIPTION
		"Applicable to all units. The trap is send if the 
		ethernet broadcast filter threshold is exceeded
		and it contains the number of dropped packets."
    ::= { brzAccessVLProducts 109 }

brzaccVLAUSUnsupportedSubscriberTypeTRAP NOTIFICATION-TYPE
        OBJECTS
        {
			brzaccVLTrapSUMacAddr,
			brzaccVLTrapSubscriberType
		}
        STATUS current
        DESCRIPTION
		"Applicable to AUS only.
		This trap is generated when a subscriber with unsupported type tries to associate to AUS.
		The AUS supports only SU-3 and SU-6.
		The first variable of the trap is the subscriber MAC Address.
		The second variable is the type of subscriber"
    ::= { brzAccessVLProducts 110 }
  

brzaccVLUnitTypeChangedTRAP NOTIFICATION-TYPE
        OBJECTS
        {
			brzaccVLTrapMACAddress,
			brzaccVLNewUnitTypeTrap
		}
        STATUS current
        DESCRIPTION
		"Applicable to BU/RB only.
		This trap is generated when the user change the type of the BreezeNET B unit.
		The RB can be converted in BU or vice versa.
		The first variable of the trap is the unit MAC Address.
		The second variable is the new type of the unit"
    ::= { brzAccessVLProducts 111 }

brzaccVLWLPrioritizationNotSupportedBySUTRAP NOTIFICATION-TYPE
        OBJECTS
        {
			brzaccVLTrapSUMacAddr,
			brzaccVLTrapSWVersion
		}
        STATUS current
        DESCRIPTION
		"Applicable to AU/BU only.
         This trap is generated when an SU/RB with a SW version below 4.0 
         that does not support Wireless Link Prioritization is associated 
         with an AU/BU with thw Wireless Link Prioritization Option enabled. 
		 The first variable of the trap is the SU/RB MAC Address.
		 The second variable is the SW version of the SU/RB"
    ::= { brzAccessVLProducts 112 }
END