summaryrefslogtreecommitdiff
path: root/MIBS/arris/d5/ARRIS-D5-ENT-SENSOR-THRESH-MIB
blob: c6c62f1ab19d7635c9835cba7c76eaeae2fa2832 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
	ARRIS-D5-ENT-SENSOR-THRESH-MIB DEFINITIONS ::= BEGIN
 
		IMPORTS
			packetport, cm110, tcm, ttm, ttp, 
			cmtsMSAS, cmts1500, cmtsC3, cmtsC4, cmtsCommon, 
			mrcController, arrisGlobalAccessMib, arrisGlobalAccessProductUas, arrisD5UEQam			
				FROM ARRIS-MIB			
			entPhysicalIndex, entityPhysicalGroup			
				FROM ENTITY-MIB			
			entPhySensorType, entPhySensorScale, entPhySensorPrecision, entPhySensorValue, entPhySensorOperStatus, 
			entPhySensorUnitsDisplay, entPhySensorValueTimeStamp, entPhySensorValueUpdateRate, entitySensorCompliance, entitySensorValueGroup, 
			entPhySensorEntry			
				FROM ENTITY-SENSOR-MIB			
			OBJECT-GROUP, MODULE-COMPLIANCE			
				FROM SNMPv2-CONF			
			Integer32, OBJECT-TYPE, MODULE-IDENTITY			
				FROM SNMPv2-SMI;
	
	
		-- 1.3.6.1.4.1.4115.1.7.1.4
		arrisEntSensorThreshMIB MODULE-IDENTITY 
			LAST-UPDATED "200710100000Z" -- 10th Oct 2007
			ORGANIZATION 
				"Arris"
			CONTACT-INFO 
				"Cindy Tromer
						Postal: Arris Interactive
						        3871 Lakefield Drive
						        Suite 300
						        Suwanee, GA 30024-1242
						        U.S.A.
						Phone:  +1 770 622 8679
						E-mail: cindy.tromer@arrisi.com
						
						Initial MIB creator: Cindy Tromer
						Postal: Arris Interactive
						        3871 Lakefield Drive
						        Suite 300
						        Suwanee, GA 30024-1242
						        U.S.A.
						Phone:  +1 770 622 8679
						E-mail: cindy.tromer@arrisi.com
				"
			DESCRIPTION 
				"This is the extension Module to rfc3433 ENTITY-SENSOR-MIB."
			::= { arrisD5UEQam 4 }

		
	
	
--
-- Node definitions
--
	
		-- 1.3.6.1.4.1.4115.1.7.1.4.1
		entThreshObjects OBJECT IDENTIFIER ::= { arrisEntSensorThreshMIB 1 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.1.1
		entThreshTable OBJECT-TYPE
			SYNTAX SEQUENCE OF EntThreshEntry
			MAX-ACCESS not-accessible
			STATUS current
			DESCRIPTION
				"This table contains one row per physical sensor. 
				
				Each row contains the set of thresholds maintained
				for each pyhsical sensor."
			::= { entThreshObjects 1 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1
		entThreshEntry OBJECT-TYPE
			SYNTAX EntThreshEntry
			MAX-ACCESS not-accessible
			STATUS current
			DESCRIPTION
				"The threshold information for a particular 
				physical sensor.
				
				An entry in this table describes the upper and lower warning
				thresholds, as well as the upper and lower fatal thresholds."
			AUGMENTS { entPhySensorEntry }
			::= { entThreshTable 1 }

		
		EntThreshEntry ::=
			SEQUENCE { 
				entLowerWarnThresh
					Integer32,
				entUpperWarnThresh
					Integer32,
				entLowerFatalThresh
					Integer32,
				entUpperFatalThresh
					Integer32
			 }

		-- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.1
		entLowerWarnThresh OBJECT-TYPE
			SYNTAX Integer32
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"The lower warning threshold for a physical sensor. 
				When a sensor value goes below this threshold, the 
				system will continue to operate, but the craftperson
				should evaluate the problem. "
			::= { entThreshEntry 1 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.2
		entUpperWarnThresh OBJECT-TYPE
			SYNTAX Integer32
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"The upper warning threshold for a physical sensor. 
				When a sensor value goes above this threshold, the 
				system will continue to operate, but the craftperson
				should evaluate the problem. "
			::= { entThreshEntry 2 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.3
		entLowerFatalThresh OBJECT-TYPE
			SYNTAX Integer32
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"The lower fatal threshold for a physical sensor. 
				When a sensor value goes below this threshold, the 
				system will shutdown."
			::= { entThreshEntry 3 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.1.1.1.4
		entUpperFatalThresh OBJECT-TYPE
			SYNTAX Integer32
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"The upper fatal threshold for a physical sensor. 
				When a sensor value goes above this threshold, the 
				system will shutdown."
			::= { entThreshEntry 4 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.2
		entThreshConformance OBJECT IDENTIFIER ::= { arrisEntSensorThreshMIB 2 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.2.1
		entThreshCompliances OBJECT IDENTIFIER ::= { entThreshConformance 1 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.2.1.1
		entThreshCompliance MODULE-COMPLIANCE
			STATUS current
			DESCRIPTION 
				"Description."
			MODULE -- this module
				MANDATORY-GROUPS { entThreshValueGroup }
			::= { entThreshCompliances 1 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.2.2
		entThreshGroups OBJECT IDENTIFIER ::= { entThreshConformance 2 }

		
		-- 1.3.6.1.4.1.4115.1.7.1.4.2.2.1
		entThreshValueGroup OBJECT-GROUP
			OBJECTS { entLowerWarnThresh, entUpperWarnThresh, entUpperFatalThresh, entLowerFatalThresh }
			STATUS current
			DESCRIPTION 
				"Description."
			::= { entThreshGroups 1 }

		
	
	END