1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
|
--
--defines TEMPAGER-MIB for SNMP agent extension of TemPageR
--Contents: Global Registration Module
-- TemPageR OIDs - Enterprise 20916
--Version: 2.5.1
--Date: 11 September 2007
--Developed By: AVTECH Software, Inc.
--
--Copyright (c) 2007 AVTECH Software, Inc.
--
TEMPAGER-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, IpAddress, Counter, TimeTicks
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215;
avtech OBJECT IDENTIFIER ::= { enterprises 20916 }
products OBJECT IDENTIFIER ::= { avtech 1 }
tempager OBJECT IDENTIFIER ::= { products 1 }
sensors OBJECT IDENTIFIER ::= { tempager 1 }
traps OBJECT IDENTIFIER ::= { tempager 2 }
thresholds OBJECT IDENTIFIER ::= { tempager 3 }
temperature OBJECT IDENTIFIER ::= { sensors 1 }
-- TemPageR MIB
-- Parameters
tempreading1c OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Temperature Sensor 1 (Celsius)"
::= { temperature 1 }
tempreading2c OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Temperature Sensor 2 (Celsius)"
::= { temperature 2 }
tempreading3c OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Temperature Sensor 3 (Celsius)"
::= { temperature 3 }
tempreading4c OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Temperature Sensor 4 (Celsius)"
::= { temperature 4 }
tempreading1f OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Temperature Sensor 1 (Fahrenheit)"
::= { temperature 5 }
tempreading2f OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Temperature Sensor 2 (Fahrenheit)"
::= { temperature 6 }
tempreading3f OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Temperature Sensor 3 (Fahrenheit)"
::= { temperature 7 }
tempreading4f OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Temperature Sensor 4 (Fahrenheit)"
::= { temperature 8 }
alarmtemp1 OBJECT-TYPE
SYNTAX INTEGER(0..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Alarm for temperature 1
0 = temperature OK
1 = temperature too high
2 = temperature too low"
::= { traps 1 }
alarmtemp2 OBJECT-TYPE
SYNTAX INTEGER(0..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Alarm for temperature 2
0 = temperature OK
1 = temperature too high
2 = temperature too low"
::= { traps 2 }
alarmtemp3 OBJECT-TYPE
SYNTAX INTEGER(0..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Alarm for temperature 3
0 = temperature OK
1 = temperature too high
2 = temperature too low"
::= { traps 3 }
alarmtemp4 OBJECT-TYPE
SYNTAX INTEGER(0..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Alarm for temperature 4
0 = temperature OK
1 = temperature too high
2 = temperature too low"
::= { traps 4 }
alarmmessage OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION "Message string to send with trap messages"
::= { traps 5 }
upperlimit1 OBJECT-TYPE
SYNTAX INTEGER(0..15000)
ACCESS read-only
STATUS mandatory
DESCRIPTION "High temperature threshold for temperature sensor 1"
::= { thresholds 1 }
lowerlimit1 OBJECT-TYPE
SYNTAX INTEGER(0..15000)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Low temperature threshold for temperature sensor 1"
::= { thresholds 2 }
upperlimit2 OBJECT-TYPE
SYNTAX INTEGER(0..15000)
ACCESS read-only
STATUS mandatory
DESCRIPTION "High temperature threshold for temperature sensor 2"
::= { thresholds 3 }
lowerlimit2 OBJECT-TYPE
SYNTAX INTEGER(0..15000)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Low temperature threshold for temperature sensor 2"
::= { thresholds 4 }
upperlimit3 OBJECT-TYPE
SYNTAX INTEGER(0..15000)
ACCESS read-only
STATUS mandatory
DESCRIPTION "High temperature threshold for temperature sensor 3"
::= { thresholds 5 }
lowerlimit3 OBJECT-TYPE
SYNTAX INTEGER(0..15000)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Low temperature threshold for temperature sensor 3"
::= { thresholds 6 }
upperlimit4 OBJECT-TYPE
SYNTAX INTEGER(0..15000)
ACCESS read-only
STATUS mandatory
DESCRIPTION "High temperature threshold for temperature sensor 4"
::= { thresholds 7 }
lowerlimit4 OBJECT-TYPE
SYNTAX INTEGER(0..15000)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Low temperature threshold for temperature sensor 4"
::= { thresholds 8 }
-- TEMPAGER TRAPS
alarmstart1-t4 TRAP-TYPE
ENTERPRISE tempager
VARIABLES { alarmmessage, tempreading1c, tempreading1f }
DESCRIPTION "A alarmstart1 trap signifies that the current
temperature on sensor 1 is outside the
defined high or low threshold."
::= 1
tempager-snmp-trap TRAP-TYPE
ENTERPRISE tempager
VARIABLES { alarmmessage, tempreading1c, tempreading1f, tempreading2c, tempreading2f, tempreading3c, tempreading3f, tempreading4c, tempreading4f }
DESCRIPTION "A tempager-snmp-trap indicates that an alarm
condition has occurred on the sensor inidcated
by the alarmmessage variable."
::= 2
alarmstart2-t4 TRAP-TYPE
ENTERPRISE tempager
VARIABLES { alarmmessage, tempreading2c, tempreading2f }
DESCRIPTION "A alarmstart2 trap signifies that the current
temperature on sensor 2 is outside the
defined high or low threshold."
::= 3
alarmclear2-t4 TRAP-TYPE
ENTERPRISE tempager
VARIABLES { alarmmessage, tempreading2c, tempreading2f }
DESCRIPTION "A alarmclear2 trap signifies that the current
temperature on sensor 2 has returned to a
normal condition and is within the defined
high or low threshold."
::= 4
alarmstart3-t4 TRAP-TYPE
ENTERPRISE tempager
VARIABLES { alarmmessage, tempreading3c, tempreading3f }
DESCRIPTION "A alarmstart3 trap signifies that the current
temperature on sensor 3 is outside the
defined high or low threshold."
::= 5
alarmclear3-t4 TRAP-TYPE
ENTERPRISE tempager
VARIABLES { alarmmessage, tempreading3c, tempreading3f }
DESCRIPTION "A alarmclear3 trap signifies that the current
temperature on sensor 3 has returned to a
normal condition and is within the defined
high or low threshold."
::= 6
alarmstart4-t4 TRAP-TYPE
ENTERPRISE tempager
VARIABLES { alarmmessage, tempreading4c, tempreading4f }
DESCRIPTION "A alarmstart4 trap signifies that the current
temperature on sensor 4 is outside the
defined high or low threshold."
::= 7
alarmclear4-t4 TRAP-TYPE
ENTERPRISE tempager
VARIABLES { alarmmessage, tempreading4c, tempreading4f }
DESCRIPTION "A alarmclear4 trap signifies that the current
temperature on sensor 4 has returned to a
normal condition and is within the defined
high or low threshold."
::= 8
END
|