1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
|
-- This file is corresponding to Release 10.2.3.100 from 2018/07/18 00:00:00
-- (C)opyright 1991-2014 bintec elmeg GmbH, All Rights Reserved
-- $RCSfile: mib-resource,v $
-- $Revision: 1.6 $
BIANCA-BRICK-MIBRES-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter, enterprises
FROM RFC1155-SMI
Unsigned32
FROM SNMPv2-SMI
DisplayString
FROM RFC1158-MIB
OBJECT-TYPE
FROM RFC-1212
resource
FROM BINTEC-MIB;
resourceMIB MODULE-IDENTITY
LAST-UPDATED "201204120000Z"
ORGANIZATION "bintec elmeg GmbH"
CONTACT-INFO
"EMail: info@bintec-elmeg.com
Web: www.bintec-elmeg.com
"
DESCRIPTION
"The MIB module for resource administration entities.
"
::= { resource 255 }
-- System Resources
cpuTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The CpuTable contains information about
the processor statistics in the system."
::= { resource 1 }
cpuEntry OBJECT-TYPE
SYNTAX CpuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { cpuNumber }
::= { cpuTable 1 }
CpuEntry ::=
SEQUENCE {
cpuNumber INTEGER,
cpuDescr DisplayString,
cpuTotalUser INTEGER,
cpuTotalSystem INTEGER,
cpuTotalStreams INTEGER,
cpuTotalIdle INTEGER,
cpuLoadUser INTEGER,
cpuLoadSystem INTEGER,
cpuLoadStreams INTEGER,
cpuLoadIdle INTEGER,
cpuLoadUser10s INTEGER,
cpuLoadSystem10s INTEGER,
cpuLoadStreams10s INTEGER,
cpuLoadIdle10s INTEGER,
cpuLoadUser60s INTEGER,
cpuLoadSystem60s INTEGER,
cpuLoadStreams60s INTEGER,
cpuLoadIdle60s INTEGER
}
cpuNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CPU Number."
::= { cpuEntry 1 }
cpuDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of CPU."
::= { cpuEntry 2 }
cpuTotalUser OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total time in seconds spent in user mode since booting."
::= { cpuEntry 3 }
cpuTotalSystem OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total time in seconds spent in sytem mode since booting."
::= { cpuEntry 4 }
cpuTotalStreams OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total time in seconds spent with streams processing since booting."
::= { cpuEntry 5 }
cpuTotalIdle OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total idle time in seconds since booting."
::= { cpuEntry 6 }
cpuLoadUser OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of time spent in user mode for the last second."
::= { cpuEntry 7 }
cpuLoadSystem OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of time spent in system mode for the last second."
::= { cpuEntry 8 }
cpuLoadStreams OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of time spent with streams processing for the last second."
::= { cpuEntry 9 }
cpuLoadIdle OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of idle time for the last second."
::= { cpuEntry 10 }
cpuLoadUser10s OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of time spent in user mode for the last 10 seconds."
::= { cpuEntry 11 }
cpuLoadSystem10s OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of time spent in system mode for the last 10 seconds."
::= { cpuEntry 12 }
cpuLoadStreams10s OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of time spent with streams processing for the last 10 seconds."
::= { cpuEntry 13 }
cpuLoadIdle10s OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of idle time measured for the last 10 seconds."
::= { cpuEntry 14 }
cpuLoadUser60s OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of time spent in user mode for the last 60 seconds."
::= { cpuEntry 15 }
cpuLoadSystem60s OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of time spent in system mode for the last 60 seconds."
::= { cpuEntry 16 }
cpuLoadStreams60s OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of time spent with streams processing for the last 60 seconds."
::= { cpuEntry 17 }
cpuLoadIdle60s OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of idle time measured for the last 60 seconds."
::= { cpuEntry 18 }
memoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF MemoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The memoryTable contains information about
the different memory in the system."
::= { resource 2 }
memoryEntry OBJECT-TYPE
SYNTAX MemoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { memoryType }
::= { memoryTable 1 }
MemoryEntry ::=
SEQUENCE {
memoryType INTEGER,
memoryDescr DisplayString,
memoryBlockSize INTEGER,
memoryTotal INTEGER,
memoryInuse INTEGER,
memoryDramUse INTEGER,
memoryNAllocs INTEGER,
memoryNFrees INTEGER,
memoryNFails INTEGER
}
memoryType OBJECT-TYPE
SYNTAX INTEGER { flash(1), dram(2), dpool(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of memory:
flash (1) : Non volatile memory
dram (2) : Dynamic memory
dpool (3) : Dynamic pool
"
::= { memoryEntry 1 }
memoryDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of memory."
::= { memoryEntry 2 }
memoryBlockSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Allocation size for memories from dpools."
::= { memoryEntry 3 }
memoryTotal OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Amount of available units of this memory type measured in
units for dpools and bytes for flash/dram."
::= { memoryEntry 4 }
memoryInuse OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Used units of this memory type measured in units for dpools
and bytes for flash/dram."
::= { memoryEntry 5 }
memoryDramUse OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"dpools might take memory from dram. This variable gives the
amount in bytes taken from a dram memory."
::= { memoryEntry 6 }
memoryNAllocs OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of memory allocations."
::= { memoryEntry 7 }
memoryNFrees OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of memory free operations."
::= { memoryEntry 8 }
memoryNFails OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of failed memory operations."
::= { memoryEntry 9 }
dspTable OBJECT-TYPE
SYNTAX SEQUENCE OF DspEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DspTable contains information about
Digital Signal processors in the system."
::= { resource 3 }
dspEntry OBJECT-TYPE
SYNTAX DspEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { dspSlot, dspUnit }
::= { dspTable 1 }
DspEntry ::=
SEQUENCE {
dspSlot INTEGER,
dspUnit INTEGER,
dspDescr DisplayString,
dspCapabilities BITS,
dspTotalChannels INTEGER,
dspUsedChannels INTEGER
}
dspSlot OBJECT-TYPE
SYNTAX INTEGER (0..512)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DSP Slot Number."
::= { dspEntry 1 }
dspUnit OBJECT-TYPE
SYNTAX INTEGER (0..9999)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DSP Unit Number."
::= { dspEntry 2 }
dspDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of DSP."
::= { dspEntry 3 }
dspCapabilities OBJECT-TYPE
SYNTAX BITS {
g711(0),
g722(1),
g723(2),
g728(3),
g726(4),
g729(5),
ilbc(6),
clear(7),
t30(8),
t38(9),
dtmf(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This bitfield describes what the DSP supports."
::= { dspEntry 4 }
dspTotalChannels OBJECT-TYPE
SYNTAX INTEGER (1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of channels of this DSP."
::= { dspEntry 5 }
dspUsedChannels OBJECT-TYPE
SYNTAX INTEGER (1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of used channels of this DSP."
::= { dspEntry 6 }
END
|