1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
|
-- PNETMOD-MIB 1.02
-- History:
-- 1.00 6. 11.2012 David Chvalkovsky - modified from NSD1800-MIB
-- 1.01 9. 12.2015 Dusan Ferbas - comment compatibility
-- 1.02 19. 10.2017 Vit Pekarek - Output Fuse description fixed
--
-- This is a MIB for Powernet module
PNETMOD-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE
FROM RFC-1212
Gauge, enterprises
FROM RFC1155-SMI
DisplayString, sysName
FROM RFC1213-MIB;
--
-- Type Definitions
--
OnOff ::= INTEGER {
off (0),
on (1)
}
OKFail ::= INTEGER {
OK (0),
Fail (1)
}
ValueType ::= INTEGER {
DI (1),
AI (2)
}
AlarmDescription ::= INTEGER {
InputGridFailure (1),
InputFuseFailure (2),
PowerSourceFailure (3),
PowerSourceCurrentOutOfRange (4),
BatteryVoltageOutOfRange (5),
BatteryCurrentChargeOutOfRange (6),
BatteryTemperatureOutOfRange (7),
BatteryFuseFailure (8),
OutputFuseFailure (9),
OutputStateDisconnected (10)
}
SignedNumber ::= INTEGER (-32758..32757)
Index ::= INTEGER (0..255)
TimeStamp ::= TimeTicks
--
-- Node Definitions
--
bke OBJECT IDENTIFIER ::= { enterprises 27533 }
pnetMod OBJECT IDENTIFIER ::= { bke 5 }
-- ---------------------------------------------------------- --
-- grid Group
-- ---------------------------------------------------------- --
grid OBJECT IDENTIFIER ::= { pnetMod 1 }
gridState OBJECT-TYPE
SYNTAX OKFail
ACCESS read-only
STATUS current
DESCRIPTION
"Grid State Ok/Fail value"
::= { grid 1 }
gridFuse OBJECT-TYPE
SYNTAX OKFail
ACCESS read-only
STATUS current
DESCRIPTION
"Grid Fuse Ok/Fail value"
::= { grid 2 }
-- ---------------------------------------------------------- --
-- source Group
-- ---------------------------------------------------------- --
powerSource OBJECT IDENTIFIER ::= { pnetMod 2 }
powerSourceState OBJECT-TYPE
SYNTAX OKFail
ACCESS read-only
STATUS current
DESCRIPTION
"Power Source State Ok/Fail value"
::= { powerSource 1 }
powerSourceCurrent OBJECT-TYPE
SYNTAX SignedNumber
ACCESS read-only
STATUS current
DESCRIPTION
"Power Source Current value XXXX divide by 10 to get XXX.X"
::= { powerSource 2 }
-- ---------------------------------------------------------- --
-- accumulator Group
-- ---------------------------------------------------------- --
accumulator OBJECT IDENTIFIER ::= { pnetMod 3 }
accuVoltage OBJECT-TYPE
SYNTAX SignedNumber
ACCESS read-only
STATUS current
DESCRIPTION
"Accumulator Voltage value XXXX divide by 10 to get XXX.X"
::= { accumulator 1 }
accuCurrent OBJECT-TYPE
SYNTAX SignedNumber
ACCESS read-only
STATUS current
DESCRIPTION
"Accumulator Current value XXXX divide by 10 to get XXX.X"
::= { accumulator 2 }
accuTemperature OBJECT-TYPE
SYNTAX SignedNumber
ACCESS read-only
STATUS current
DESCRIPTION
"Accumulator Temperature value -XXX divide by 10 to get -XX.X"
::= { accumulator 3 }
accuFuse OBJECT-TYPE
SYNTAX OKFail
ACCESS read-only
STATUS current
DESCRIPTION
"Accumulator Fuse Ok/Fail value"
::= { accumulator 4 }
-- ---------------------------------------------------------- --
-- output Group
-- ---------------------------------------------------------- --
output OBJECT IDENTIFIER ::= { pnetMod 4 }
outFuse OBJECT-TYPE
SYNTAX OKFail
ACCESS read-only
STATUS current
DESCRIPTION
"Output Fuse Ok/Fail value"
::= { output 1 }
outState OBJECT-TYPE
SYNTAX OnOff
ACCESS read-write
STATUS current
DESCRIPTION
"Output State On/Off value"
::= { output 2 }
-- ---------------------------------------------------------- --
-- Alarm Group
-- ---------------------------------------------------------- --
alarms OBJECT IDENTIFIER ::= { pnetMod 10 }
alarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of input entries."
::= { alarms 1 }
alarmEntry OBJECT-TYPE
SYNTAX AlarmEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing information applicable
to a particular input."
INDEX { alarmIndex }
::= { alarmTable 1 }
AlarmEntry ::= SEQUENCE {
alarmIndex Index,
alarmDescription AlarmDescription,
valueType ValueType,
value SignedNumber,
alarmTimeStamp TimeStamp
}
alarmIndex OBJECT-TYPE
SYNTAX Index
ACCESS read-only
STATUS current
DESCRIPTION
"The input index."
::= { alarmEntry 1 }
alarmDescription OBJECT-TYPE
SYNTAX AlarmDescription
ACCESS read-only
STATUS current
DESCRIPTION
"The input alarm description."
::= { alarmEntry 2 }
valueType OBJECT-TYPE
SYNTAX ValueType
ACCESS read-only
STATUS current
DESCRIPTION
"The input digital or analog type."
::= { alarmEntry 3 }
value OBJECT-TYPE
SYNTAX SignedNumber
ACCESS read-only
STATUS current
DESCRIPTION
"The input alarm value."
::= { alarmEntry 4 }
alarmTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
ACCESS read-only
STATUS current
DESCRIPTION
"The input alarm duration."
::= { alarmEntry 5 }
-- ---------------------------------------------------------- --
-- Trap Definitions
-- ---------------------------------------------------------- --
tsTrapAlarmStart TRAP-TYPE
ENTERPRISE pnetMod
VARIABLES { sysName, alarmDescription, valueType, value }
DESCRIPTION
"This trap is sent each time an alarm is inserted
into the alarm table."
::= 1
tsTrapAlarmEnd TRAP-TYPE
ENTERPRISE pnetMod
VARIABLES { sysName, alarmDescription, valueType, value }
DESCRIPTION
"This trap is sent each time an alarm is removed
from the alarm table."
::= 2
END
|