1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
|
OCCAM-MLT-MIB DEFINITIONS ::= BEGIN
IMPORTS
occamGenericMonitorModules
FROM OCCAM-REG-MODULE
TEXTUAL-CONVENTION
FROM SNMPv2-TC
MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY,
Integer32, NOTIFICATION-TYPE
FROM SNMPv2-SMI;
occamMltMib MODULE-IDENTITY
LAST-UPDATED "200104271051Z"
ORGANIZATION "Occam Networks"
CONTACT-INFO "email support@occamnetworks.com"
DESCRIPTION
"This mib module describes objects used
to perform Metallic Line Testing on customer
access lines and to provide results."
REVISION "200104271051Z"
DESCRIPTION "Reformatted certain text"
REVISION "200704170000Z"
DESCRIPTION "replace kOhm with Ohm in DC resistance
UNITS"
REVISION "200702220000Z"
DESCRIPTION "remove DISPLAY-HINT"
REVISION "200609261000Z"
DESCRIPTION "Removed Gr909 from fuse test result names"
REVISION "200602220135Z"
DESCRIPTION "Initial version."
::= { occamGenericMonitorModules 3 }
-- TEXTUAL-CONVENTIONS --
MltTestType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A selection value for requesting or forcing
a test. A requested test will only run if the
port is not in use. A forced test will
immediately shut the port and run the test."
SYNTAX INTEGER { request ( 1 ) ,
force ( 2 ) }
MltTestStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An indication of test status:
none = no test has been requested.
mltbusy = another port is currently being tested.
complete = the last requested test has completed.
portInUse = the last requested port is in use,
the test was not run. Rerunning the test as
'forced' will shut the port and run the test.
inProgress = the last requested test is still
running. mltError = the mlt program reported an
error and aborted the test.Check the mltErrorText
object.
mltNotResponding = the mlt program didn't return
a result."
SYNTAX INTEGER {
none ( 1 ) ,
mltBusy ( 2 ),
complete ( 3 ) ,
portInUse ( 4 ) ,
inProgress ( 5 ),
mltError ( 6 ),
mltNotResponding ( 7 ) }
MltTestIdentifier ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An mlt test selection value."
SYNTAX INTEGER {
statusSuite ( 1 ) ,
mltSuite ( 2 ) ,
activeModeVoltages ( 3 ) ,
highImpedanceModeVoltages ( 4 ) ,
dcResistance ( 5 ) ,
capacitance ( 6 ) ,
loopDetect ( 7 ) ,
loopLength ( 8 ) }
MltTestHookState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An mlt test hook state value."
SYNTAX INTEGER {
onhook ( 1 ) ,
offhook ( 2 ),
notAvailable ( 3 ) }
MltTestPassFail ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An mlt test pass/fail value."
SYNTAX INTEGER {
pass ( 1 ) ,
fail ( 2 ),
notAvailable ( 3 ) }
MltTestRingerResult ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An mlt ringer test result value."
SYNTAX INTEGER {
pass ( 1 ) ,
fail ( 2 ),
notAvailable ( 3 ),
low ( 4 ) }
MltTestYesNo ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An mlt test pass/fail value."
SYNTAX INTEGER {
yes ( 1 ) ,
no ( 2 ),
notAvailable ( 3 ) }
-- The Metallic Loop Test Configuration group
mltTestConfig OBJECT IDENTIFIER
::= { occamMltMib 1 }
-- The Metallic Loop Test Status group
mltTestStatus OBJECT IDENTIFIER
::= { occamMltMib 2 }
-- The Metallic Loop Test Results group
mltTestResults OBJECT IDENTIFIER
::= { occamMltMib 3 }
-- The Metallic Loop Test Notifications group
mltTestNotifications OBJECT IDENTIFIER
::= { occamMltMib 4 }
-- Objects of the MLT Configuration group
mltTestIdentifier OBJECT-TYPE
SYNTAX MltTestIdentifier
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the mlt test to be run.
Setting this value starts a test.
This is a required parameter.
Approximate expected test durations are as
follows:
statusSuite 1 second
mltSuite 1 minute
activeModeVoltages 3 seconds
highImpedanceModeVoltages 9 seconds
dcResistance 18 seconds
capacitance 18 seconds
loopDetect 9 seconds
loopLength 9 seconds."
::= { mltTestConfig 1 }
mltTestType OBJECT-TYPE
SYNTAX MltTestType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects if a test is requested (only run if port
is not in use) or forced.
This is an optional parameter. If not specified,
the request option is used."
::= { mltTestConfig 2 }
mltTestPort OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 48 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects voice channel on which test will be run.
This is a required parameter."
::= { mltTestConfig 3 }
mltDcResistanceRange OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 3 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects DC Resistance range value.
This is an optional paramater. Default is 0
(auto mode)."
::= { mltTestConfig 4 }
mltLoopLengthMultiplier OBJECT-TYPE
SYNTAX Integer32 ( 10 .. 200 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects loop length multiplier in nf. This is an
optional parameter. If not specified an internal
default value of 83nF/mile is used."
::= { mltTestConfig 5 }
mltLoopDetectThreshold OBJECT-TYPE
SYNTAX Integer32 ( 5 .. 200 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the detection threshold in nF.
This is an optional parameter. If not supplied,
a loop detection threshold of 10nF is used."
::= { mltTestConfig 6 }
-- Objects of the MLT Test Status group
mltLastTestStatus OBJECT-TYPE
SYNTAX MltTestStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the status of the last run mlt test.
Given that the various mlt tests take several
seconds to 1 1/2 minutes to run, it is suggested
that status polls be spaced 10-20 seconds apart.
Additionally, a monitoring application could
wait for the testComplete notification."
::= { mltTestStatus 1 }
mltErrorText OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the textual error in the case of an
aborted test."
::= { mltTestStatus 2 }
-- Objects of the MLT Test Results group
-- mlt status results table
mltStatusResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MltStatusResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides result of the status test
suite."
::= { mltTestResults 1 }
mltStatusResultsEntry OBJECT-TYPE
SYNTAX MltStatusResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of status suite tests.
Note that a numerical result value of -999 means
that there was an error of some sort and the
value could not be measured."
INDEX { mltTestPort }
::= { mltStatusResultsTable 1 }
MltStatusResultsEntry ::= SEQUENCE {
mltStatusAlarm OCTET STRING,
mltStatusHookState MltTestHookState,
mltStatusTransversalCurrent Integer32,
mltStatusLongitudinalCurrent Integer32,
mltStatusTipVoltage Integer32,
mltStatusRingVoltage Integer32,
mltStatusTipRingVoltage Integer32,
mltStatusVdd Integer32
}
mltStatusAlarm OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when
status test was run."
::= { mltStatusResultsEntry 1 }
mltStatusHookState OBJECT-TYPE
SYNTAX MltTestHookState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates line hook state when status test was
run."
::= { mltStatusResultsEntry 2 }
mltStatusTransversalCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates transversal current when status test
was run."
::= { mltStatusResultsEntry 3 }
mltStatusLongitudinalCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates Longitudinal current when status test
was run."
::= { mltStatusResultsEntry 4 }
mltStatusTipVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates tip voltage when status test was run."
::= { mltStatusResultsEntry 5 }
mltStatusRingVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates ring voltage when status test was run."
::= { mltStatusResultsEntry 6 }
mltStatusTipRingVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates tip-ring voltage when status test was
run."
::= { mltStatusResultsEntry 7 }
mltStatusVdd OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates Vdd when status test was run."
::= { mltStatusResultsEntry 8 }
-- mlt test results table
mltTestResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MltTestResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides result of the mlt test suite.
Note that a numerical result value of -999 means
that there was an error of some sort and the
value could not be measured.
Also, a resistance value of 9999 means that the
result was greater than 1000 kOhms, but the exact
value could not be measured."
::= { mltTestResults 2 }
mltTestResultsEntry OBJECT-TYPE
SYNTAX MltTestResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of mlt suite tests."
INDEX { mltTestPort }
::= { mltTestResultsTable 1 }
MltTestResultsEntry ::= SEQUENCE {
mltTestAlarm OCTET STRING,
mltTestHookState MltTestHookState,
mltTestVdd Integer32,
mltTestActiveModeVoltagesVdctr Integer32,
mltTestActiveModeVoltagesVdctg Integer32,
mltTestActiveModeVoltagesVdcrg Integer32,
mltTestActiveModeVoltagesVactr Integer32,
mltTestActiveModeVoltagesVactg Integer32,
mltTestActiveModeVoltagesVacrg Integer32,
mltTestHighImpedanceModeVoltagesVdctr Integer32,
mltTestHighImpedanceModeVoltagesVdctg Integer32,
mltTestHighImpedanceModeVoltagesVdcrg Integer32,
mltTestHighImpedanceModeVoltagesVactr Integer32,
mltTestHighImpedanceModeVoltagesVactg Integer32,
mltTestHighImpedanceModeVoltagesVacrg Integer32,
mltTestDcCurrentsItransversal Integer32,
mltTestDcCurrentsIlongitudinal Integer32,
mltTestDcCurrentsItip Integer32,
mltTestDcCurrentsIring Integer32,
mltTestCapacitanceCeqtr Integer32,
mltTestCapacitanceCeqtg Integer32,
mltTestCapacitanceCeqrg Integer32,
mltTestResistanceRtr Integer32,
mltTestResistanceRtg Integer32,
mltTestResistanceRrg Integer32,
mltTestGr909HazardousPotentialTestResult MltTestPassFail,
mltTestGr909ForeignEmfTestResult MltTestPassFail,
mltTestGr909FuseTestTipFuse MltTestPassFail,
mltTestGr909FuseTestRingFuse MltTestPassFail,
mltTestFuseTestTipFuse MltTestPassFail,
mltTestFuseTestRingFuse MltTestPassFail,
mltTestGr909ResistiveFaultTestResult MltTestPassFail,
mltTestGr909ReceiverOffhookTestResult MltTestPassFail,
mltTestGr909ReceiverOffhookTestResistance1 Integer32,
mltTestGr909ReceiverOffhookTestResistance2 Integer32,
mltTestGr909ReceiverOffhookTestDifference Integer32,
mltTestGr909RingerTestResult MltTestRingerResult,
mltTestGr909RingerTestRen Integer32,
mltTestErrors OCTET STRING
}
mltTestAlarm OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"GNK and OTEMP bits set by the DuSLIC will be
reported as alarms. GNK is typically cause by
ground fault or foreign voltage condition.
OTEMP is set when the DuSLIC is experiencing
thermal overload. This parameter is
non-intrusive."
::= { mltTestResultsEntry 1 }
mltTestHookState OBJECT-TYPE
SYNTAX MltTestHookState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hook state reflects the DuSLIC hook bit
(offhook/onhook). This parameter is
non-intrusive."
::= { mltTestResultsEntry 2 }
mltTestVdd OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"On HDPOTS, internal Voltage VDD will be
reported and compared to statistically derived
thresholds.
This parameter is intrusive during offhook but
will be available during onhook."
::= { mltTestResultsEntry 3 }
mltTestActiveModeVoltagesVdctr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring
in a normal no shutdown state. AC voltages for
T-R, T-G and R-G will be reported.
Active mode measurements will not be available
when alarm is detected. This parameter is
intrusive and will be available in shutdown
state only."
::= { mltTestResultsEntry 4 }
mltTestActiveModeVoltagesVdctg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring
in a normal no shutdown state. AC voltages for
T-R, T-G and R-G will be reported.
Active mode measurements will not be available
when alarm is detected. This parameter is
intrusive and will be available in shutdown
state only."
::= { mltTestResultsEntry 5 }
mltTestActiveModeVoltagesVdcrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring
in a normal no shutdown state. AC voltages for
T-R, T-G and R-G will be reported.
Active mode measurements will not be available
when alarm is detected. This parameter is
intrusive and will be available in shutdown
state only."
::= { mltTestResultsEntry 6 }
mltTestActiveModeVoltagesVactr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring
in a normal no shutdown state. Thus, VT and VR
measurements should be 0 volt.
AC voltages for T-R, T-G and R-G will be
reported. Active mode measurements will not be
available when alarm is detected. This parameter
is intrusive and will be available in shutdown
state only."
::= { mltTestResultsEntry 7 }
mltTestActiveModeVoltagesVactg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring
in a normal no shutdown state. Thus, VT and VR
measurements should be 0 volt. AC voltages for T-R, T-G
and R-G will be reported. Active mode measurements will
not be available when alarm is detected. This parameter
is intrusive and will be available in shutdown state
only."
::= { mltTestResultsEntry 8 }
mltTestActiveModeVoltagesVacrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring in a
normal no shutdown state. Thus, VT and VR measurements
should be 0 volt. AC voltages for T-R, T-G and R-G will
be reported. Active mode measurements will not be
available when alarm is detected. This parameter is
intrusive and will be available in shutdown state only."
::= { mltTestResultsEntry 9 }
mltTestHighImpedanceModeVoltagesVdctr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring DC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. DC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltTestResultsEntry 10 }
mltTestHighImpedanceModeVoltagesVdctg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring DC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. DC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltTestResultsEntry 11 }
mltTestHighImpedanceModeVoltagesVdcrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring DC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. DC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltTestResultsEntry 12 }
mltTestHighImpedanceModeVoltagesVactr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring AC Voltages (Foreign
Voltages): In this mode, the DuSLIC tip and ring are in
high impedance. The measured voltages represent foreign
voltages. AC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltTestResultsEntry 13 }
mltTestHighImpedanceModeVoltagesVactg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring AC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. AC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltTestResultsEntry 14 }
mltTestHighImpedanceModeVoltagesVacrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring AC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. AC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltTestResultsEntry 15 }
mltTestDcCurrentsItransversal OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Four DC currents will be reported: IT, IL, It and Ir.
In normal condition, currents will be measured in
active mode. These measurements will not be available if
alarm is present."
::= { mltTestResultsEntry 16 }
mltTestDcCurrentsIlongitudinal OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Four DC currents will be reported: IT, IL, It and Ir.
In normal condition, currents will be measured in active
mode. These measurements will not be available if alarm
is present."
::= { mltTestResultsEntry 17 }
mltTestDcCurrentsItip OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Four DC currents will be reported: IT, IL, It and Ir.
In normal condition, currents will be measured in active
mode. These measurements will not be available if alarm
is present."
::= { mltTestResultsEntry 18 }
mltTestDcCurrentsIring OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Four DC currents will be reported: IT, IL, It and Ir.
In normal condition, currents will be measured in active
mode. These measurements will not be available if alarm
is present."
::= { mltTestResultsEntry 19 }
mltTestCapacitanceCeqtr OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Capacitance measurements will support only single
element (2 terminal) circuit. In the presence of a
network of capacitance (figure 3), the individual
capacitance will not be resolved. The equivalent
capacitances CEQtr, CEQtg and CEQrg will be reported.
They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only."
::= { mltTestResultsEntry 20 }
mltTestCapacitanceCeqtg OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Capacitance measurements will support only single
element (2 terminal)
circuit. In the presence of a network of capacitance
(figure 3), the
individual capacitance will not be resolved. The
equivalent capacitances CEQtr, CEQtg and CEQrg will be
reported. They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only."
::= { mltTestResultsEntry 21 }
mltTestCapacitanceCeqrg OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Capacitance measurements will support only single
element (2 terminal) circuit. In the presence of a
network of capacitance (figure 3), the individual
capacitance will not be resolved. The equivalent
capacitances CEQtr, CEQtg and CEQrg will be reported.
They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only."
::= { mltTestResultsEntry 22 }
mltTestResistanceRtr OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DC resistance measurements will be based on a 3
terminal circuit model. Rtr, Rtg and Rrg will be
provided. User will have the option of specifying 3
resistance ranges: (1) low, (2) medium, (3) high. If not
specified, auto mode will be used. Resistance
measurements will not be available if fuse test fails or
alarm is present. This parameter is intrusive. This test
is intrusive and will be available in shutdown state `
only."
::= { mltTestResultsEntry 23 }
mltTestResistanceRtg OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DC resistance measurements will be based on a 3
terminal circuit model. Rtr, Rtg and Rrg will be
provided. User will have the option of specifying
3 resistance ranges: (1) low, (2) medium, (3) high. If
not specified, auto mode will be used. Resistance
measurements will not be available if fuse test fails or
alarm is present. This parameter is intrusive. This test
is intrusive and will be available in shutdown state
only."
::= { mltTestResultsEntry 24 }
mltTestResistanceRrg OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DC resistance measurements will be based on a 3
terminal circuit model. Rtr, Rtg and Rrg will be
provided. User will have the option of specifying
3 resistance ranges: (1) low, (2) medium, (3) high. If
not specified, auto mode will be used. Resistance
measurements will not be available if fuse test fails or
alarm is present. This parameter is intrusive. This test
is intrusive and will be available in shutdown state
only."
::= { mltTestResultsEntry 25 }
mltTestGr909HazardousPotentialTestResult OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails if the T-G or R-G ac voltage is greater
than 50 volts rms or the T-G or R-G dc voltage is
greater than 135 volts. This test will report pass/fail.
This test is intrusive and will be available in shutdown
state only."
::= { mltTestResultsEntry 26 }
mltTestGr909ForeignEmfTestResult OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails if the T-G or R-G ac voltage is greater
than 50 volts rms or the T-G or R-G dc voltage is
greater than 135 volts. This test will report pass/fail.
This test is intrusive and will be available in shutdown
state only."
::= { mltTestResultsEntry 27 }
mltTestGr909FuseTestTipFuse OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This test determines if these fuses are blown. This
test will return pass/fail for tip and ring. This test
will not be performed if alarm is present. This
parameter is intrusive. This test is intrusive and will
be available in shutdown state only.
This object is obsolete. Object name was changed."
::= { mltTestResultsEntry 28 }
mltTestGr909FuseTestRingFuse OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This test determines if these fuses are blown. This
test will return pass/fail for tip and ring. This test
will not be performed if alarm is present. This
parameter is intrusive. This test is intrusive and will
be available in shutdown state only.
This object is obsolete. Object name was changed."
::= { mltTestResultsEntry 29 }
mltTestFuseTestTipFuse OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test determines if these fuses are blown. This
test will return pass/fail for tip and ring. This test
will not be performed if alarm is present. This
parameter is intrusive. This test is intrusive and will
be available in shutdown state only."
::= { mltTestResultsEntry 38 }
mltTestFuseTestRingFuse OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test determines if these fuses are blown. This
test will return pass/fail for tip and ring. This test
will not be performed if alarm is present. This
parameter is intrusive. This test is intrusive and will
be available in shutdown state only."
::= { mltTestResultsEntry 39 }
mltTestGr909ResistiveFaultTestResult OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails if the T-R, T-G or R-G dc resistance is
less than 150k ohm. This test will not be performed if
fuse test fails or alarm is present. This test will
return pass/fail. This test is intrusive and will be
available in shutdown state only."
::= { mltTestResultsEntry 30 }
mltTestGr909ReceiverOffhookTestResult OBJECT-TYPE
SYNTAX MltTestPassFail
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails if a non-linearity in the T-R dc
resistance of greater than 15% when measured at two
different voltage levels exists. This test will not be
performed if fuse test fails or alarm is present. This
test will return the DC resistances at two different
operating points and the percent difference between the
two DC resistances. This test is intrusive and will be
available in shutdown state only. "
::= { mltTestResultsEntry 31 }
mltTestGr909ReceiverOffhookTestResistance1 OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails if a non-linearity in the T-R dc
resistance of greater than 15% when measured at two
different voltage levels exists. This test will not be
performed if fuse test fails or alarm is present. This
test will return the DC resistances at two different
operating points and the percent difference between the
two DC resistances. This test is intrusive and will be
available in shutdown state only. "
::= { mltTestResultsEntry 32 }
mltTestGr909ReceiverOffhookTestResistance2 OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails if a non-linearity in the T-R dc
resistance of greater than 15% when measured at two
different voltage levels exists. This test will not be
performed if fuse test fails or alarm is present. This
test will return the DC resistances at two different
operating points and the percent difference between the
two DC resistances. This test is intrusive and will be
available in shutdown state only. "
::= { mltTestResultsEntry 33 }
mltTestGr909ReceiverOffhookTestDifference OBJECT-TYPE
SYNTAX Integer32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails if a non-linearity in the T-R dc
resistance of greater than 15% when measured at two
different voltage levels exists. This test will not be
performed if fuse test fails or alarm is present. This
test will return the DC resistances at two different
operating points and the percent difference between the
two DC resistances. This test is intrusive and will be
available in shutdown state only. "
::= { mltTestResultsEntry 34 }
mltTestGr909RingerTestResult OBJECT-TYPE
SYNTAX MltTestRingerResult
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails when the equivalent ringer count across
tip and ring is less than 0.175 REN or greater than 5
REN. This test will not run if fuse test fails or alarm
is present. This test will report passed/fail and the
REN number. This parameter is intrusive and will be
available in shutdown state shutdown only."
::= { mltTestResultsEntry 35 }
mltTestGr909RingerTestRen OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 REN"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This test fails when the equivalent ringer count across
tip and ring is less than 0.175 REN or greater than 5
REN. This test will not run if fuse test fails or alarm
is present. This test will report passed/fail and the
REN number. This parameter is intrusive and will be
available in shutdown state shutdown only."
::= { mltTestResultsEntry 36 }
mltTestErrors OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when test was
run."
::= { mltTestResultsEntry 37 }
-- mlt active mode voltages results table
mltActiveModeVoltagesResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MltActiveModeVoltagesResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides results of the mlt active mode
voltages test.
Note that a numerical result value of -999 means that
there was an error of some sort and the value could not
be measured."
::= { mltTestResults 3 }
mltActiveModeVoltagesResultsEntry OBJECT-TYPE
SYNTAX MltActiveModeVoltagesResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of mlt active mode voltages test."
INDEX { mltTestPort }
::= { mltActiveModeVoltagesResultsTable 1 }
MltActiveModeVoltagesResultsEntry ::= SEQUENCE {
mltActiveModeVoltagesVdctr Integer32,
mltActiveModeVoltagesVdctg Integer32,
mltActiveModeVoltagesVdcrg Integer32,
mltActiveModeVoltagesVactr Integer32,
mltActiveModeVoltagesVactg Integer32,
mltActiveModeVoltagesVacrg Integer32,
mltActiveModeVoltagesErrors OCTET STRING
}
mltActiveModeVoltagesVdctr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring in a
normal no shutdown state. AC voltages for T-R, T-G and
R-G will be reported.
Active mode measurements will not be available when
alarm is detected. This parameter is intrusive and will
be available in shutdown state only."
::= { mltActiveModeVoltagesResultsEntry 1 }
mltActiveModeVoltagesVdctg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring in a
normal no shutdown state. AC voltages for T-R, T-G and
R-G will be reported. Active mode measurements will not
be available when alarm is detected. This parameter is
intrusive and will be available in shutdown state only."
::= { mltActiveModeVoltagesResultsEntry 2 }
mltActiveModeVoltagesVdcrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring in a
normal no shutdown state. AC voltages for T-R, T-G and
R-G will be reported. Active mode measurements will not
be available when alarm is detected. This parameter is
intrusive and will be available in shutdown state only."
::= { mltActiveModeVoltagesResultsEntry 3 }
mltActiveModeVoltagesVactr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring in a
normal no shutdown state. Thus, VT and VR measurements
should be 0 volt. AC voltages for T-R, T-G and R-G will
be reported. Active mode measurements will not be
available when alarm is detected. This parameter is
intrusive and will be available in shutdown state only."
::= { mltActiveModeVoltagesResultsEntry 4 }
mltActiveModeVoltagesVactg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring in a
normal no shutdown state. Thus, VT and VR measurements
should be 0 volt. AC voltages for T-R, T-G and R-G will
be reported. Active mode measurements will not be
available when alarm is detected. This parameter is
intrusive and will be available in shutdown state only."
::= { mltActiveModeVoltagesResultsEntry 5 }
mltActiveModeVoltagesVacrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring in a
normal no shutdown state. Thus, VT and VR measurements
should be 0 volt. AC voltages for T-R, T-G and R-G will
be reported.
Active mode measurements will not be available when
alarm is detected. This parameter is intrusive and will
be available in shutdown state only."
::= { mltActiveModeVoltagesResultsEntry 6 }
mltActiveModeVoltagesErrors OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when test was
run."
::= { mltActiveModeVoltagesResultsEntry 7 }
-- mlt high impedance mode voltages results table
mltHighImpedanceModeVoltagesResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF
MltHighImpedanceModeVoltagesResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides result of the mlt test suite.
Note that a numerical result value of -999 means that
there was an error of some sort and the value could not
be measured."
::= { mltTestResults 4 }
mltHighImpedanceModeVoltagesResultsEntry OBJECT-TYPE
SYNTAX MltHighImpedanceModeVoltagesResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of mlt high impedance mode voltages test."
INDEX { mltTestPort }
::= { mltHighImpedanceModeVoltagesResultsTable 1 }
MltHighImpedanceModeVoltagesResultsEntry ::= SEQUENCE {
mltHighImpedanceModeVoltagesVdctr Integer32,
mltHighImpedanceModeVoltagesVdctg Integer32,
mltHighImpedanceModeVoltagesVdcrg Integer32,
mltHighImpedanceModeVoltagesVactr Integer32,
mltHighImpedanceModeVoltagesVactg Integer32,
mltHighImpedanceModeVoltagesVacrg Integer32,
mltHighImpedanceModeVoltagesErrors OCTET STRING
}
mltHighImpedanceModeVoltagesVdctr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring DC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. DC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltHighImpedanceModeVoltagesResultsEntry 1 }
mltHighImpedanceModeVoltagesVdctg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring DC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. DC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltHighImpedanceModeVoltagesResultsEntry 2 }
mltHighImpedanceModeVoltagesVdcrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vdc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring DC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. DC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltHighImpedanceModeVoltagesResultsEntry 3 }
mltHighImpedanceModeVoltagesVactr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring AC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. AC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltHighImpedanceModeVoltagesResultsEntry 4 }
mltHighImpedanceModeVoltagesVactg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring AC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. AC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltHighImpedanceModeVoltagesResultsEntry 5 }
mltHighImpedanceModeVoltagesVacrg OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Vrms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Impedance Mode Tip/Ring AC Voltages (Foreign
Voltages):
In this mode, the DuSLIC tip and ring are in high
impedance. The measured voltages represent foreign
voltages. AC voltages for T-R, T-G and R-G will be
reported. This parameter is intrusive and will be
available in shutdown state only."
::= { mltHighImpedanceModeVoltagesResultsEntry 6 }
mltHighImpedanceModeVoltagesErrors OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when test was
run."
::= { mltHighImpedanceModeVoltagesResultsEntry 7 }
-- mlt DC resistance results table
mltDcResistanceResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MltDcResistanceResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides result of the DC resistance test.
Note that a numerical result value of -999 means that
there was an error of some sort and the value could not
be measured. Also, a resistance value of 9999 means
that the result was greater than 1000 kOhms, but the
exact value could not be measured."
::= { mltTestResults 5 }
mltDcResistanceResultsEntry OBJECT-TYPE
SYNTAX MltDcResistanceResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of mlt DC resistance test."
INDEX { mltTestPort }
::= { mltDcResistanceResultsTable 1 }
MltDcResistanceResultsEntry ::= SEQUENCE {
mltDcResistanceRtr Integer32,
mltDcResistanceRtg Integer32,
mltDcResistanceRrg Integer32,
mltDcResistanceErrors OCTET STRING
}
mltDcResistanceRtr OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DC resistance measurements will be based on a 3
terminal circuit model. Rtr, Rtg and Rrg will be
provided. User will have the option of specifying
3 resistance ranges: (1) low, (2) medium, (3) high. If
not specified, auto mode will be used. Resistance
measurements will not be available if fuse test fails or
alarm is present. This parameter is intrusive. This test
is intrusive and will be available in shutdown state
only."
::= { mltDcResistanceResultsEntry 1 }
mltDcResistanceRtg OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DC resistance measurements will be based on a 3
terminal circuit model. Rtr, Rtg and Rrg will be
provided. User will have the option of specifying
3 resistance ranges: (1) low, (2) medium, (3) high. If
not specified, auto mode will be used. Resistance
measurements will not be available if fuse test fails or
alarm is present. This parameter is intrusive. This test
is intrusive and will be available in shutdown state
only."
::= { mltDcResistanceResultsEntry 2 }
mltDcResistanceRrg OBJECT-TYPE
SYNTAX Integer32
UNITS "Ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DC resistance measurements will be based on a 3
terminal circuit model. Rtr, Rtg and Rrg will be
provided. User will have the option of specifying
3 resistance ranges: (1) low, (2) medium, (3) high. If
not specified, auto mode will be used. Resistance
measurements will not be available if fuse test fails or
alarm is present. This parameter is intrusive. This test
is intrusive and will be available in shutdown state
only."
::= { mltDcResistanceResultsEntry 3 }
mltDcResistanceErrors OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when test was
run."
::= { mltDcResistanceResultsEntry 4 }
-- mlt capacitance results table
mltCapacitanceResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MltCapacitanceResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides result of the mlt test suite.
Note that a numerical result value of -999 means that
there was an error of some sort and the value could not
be measured."
::= { mltTestResults 6 }
mltCapacitanceResultsEntry OBJECT-TYPE
SYNTAX MltCapacitanceResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of mlt capacitance test."
INDEX { mltTestPort }
::= { mltCapacitanceResultsTable 1 }
MltCapacitanceResultsEntry ::= SEQUENCE {
mltCapacitanceCeqtr Integer32,
mltCapacitanceCeqtg Integer32,
mltCapacitanceCeqrg Integer32,
mltCapacitanceErrors OCTET STRING
}
mltCapacitanceCeqtr OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Capacitance measurements will support only single
element (2 terminal) circuit. In the presence of a
network of capacitance (figure 3), the individual
capacitance will not be resolved. The equivalent
capacitances CEQtr, CEQtg and CEQrg will be reported.
They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only."
::= { mltCapacitanceResultsEntry 1 }
mltCapacitanceCeqtg OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Capacitance measurements will support only single
element (2 terminal) circuit. In the presence of a
network of capacitance (figure 3), the individual
capacitance will not be resolved. The equivalent
capacitances CEQtr, CEQtg and CEQrg will be reported.
They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only."
::= { mltCapacitanceResultsEntry 2 }
mltCapacitanceCeqrg OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Capacitance measurements will support only single
element (2 terminal) circuit. In the presence of a
network of capacitance (figure 3), the individual
capacitance will not be resolved. The equivalent
capacitances CEQtr, CEQtg and CEQrg will be reported.
They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only."
::= { mltCapacitanceResultsEntry 3 }
mltCapacitanceErrors OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when test was
run."
::= { mltCapacitanceResultsEntry 4 }
-- mlt loop detect results table
mltLoopDetectResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MltLoopDetectResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides result of the mlt loop detect test.
Note that a numerical result value of -999 means that
there was an error of some sort and the value could not
be measured."
::= { mltTestResults 7 }
mltLoopDetectResultsEntry OBJECT-TYPE
SYNTAX MltLoopDetectResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of mlt loop detect test."
INDEX { mltTestPort }
::= { mltLoopDetectResultsTable 1 }
MltLoopDetectResultsEntry ::= SEQUENCE {
mltLoopDetectLoopCapacitance Integer32,
mltLoopDetectDetectionThreshold Integer32,
mltLoopDetectLoopDetected MltTestYesNo,
mltLoopDetectErrors OCTET STRING
}
mltLoopDetectLoopCapacitance OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop detection will be based on tip-ring capacitance
measurement. User will be able to specify the detection
threshold. If not supplied,loop detection threshold of
10 nF will be used. This test will not be available if
fuse test fails or alarm is present. This test is
intrusive and will be available in shutdown state only."
::= { mltLoopDetectResultsEntry 1 }
mltLoopDetectDetectionThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop detection will be based on tip-ring capacitance
measurement. User will be able to specify the detection
threshold. If not supplied, loop detection threshold of
10 nF will be used. This test will not be available if
fuse test fails or alarm is present. This test is
intrusive and will be available in shutdown state only."
::= { mltLoopDetectResultsEntry 2 }
mltLoopDetectLoopDetected OBJECT-TYPE
SYNTAX MltTestYesNo
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop detection will be based on tip-ring capacitance
measurement. User will be able to specify the detection
threshold. If not supplied, loop detection threshold
of 10 nF will be used. This test will not be available
if fuse test fails or alarm is present. This test is
intrusive and will be available in shutdown state only."
::= { mltLoopDetectResultsEntry 3 }
mltLoopDetectErrors OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when test
was run."
::= { mltLoopDetectResultsEntry 4 }
-- mlt loop length results table
mltLoopLengthResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MltLoopLengthResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides result of the mlt loop length test.
Note that a numerical result value of -999 means that
there was an error of some sort and the value could
not be measured."
::= { mltTestResults 8 }
mltLoopLengthResultsEntry OBJECT-TYPE
SYNTAX MltLoopLengthResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry holding information about results
of mlt loop length test."
INDEX { mltTestPort }
::= { mltLoopLengthResultsTable 1 }
MltLoopLengthResultsEntry ::= SEQUENCE {
mltLoopLengthCapacitanceFactor Integer32,
mltLoopLengthLoopCapacitance Integer32,
mltLoopLengthLoopLength Integer32,
mltLoopLengthUncompensatedLoopCapacitance Integer32,
mltLoopLengthUncompensatedLoopLength Integer32,
mltLoopLengthErrors OCTET STRING
}
mltLoopLengthCapacitanceFactor OBJECT-TYPE
SYNTAX Integer32
UNITS "nF/mile"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop length estimate will be based on tip-ring
capacitance measurement. User will be able to
specify the loop length multiplier. If not supplied,
loop length multiplier of 83 nF/ mile will be used.
This test will not be available if fuse test fails
or alarm is present. This test is intrusive and will
be available in shutdown state only."
::= { mltLoopLengthResultsEntry 1 }
mltLoopLengthLoopCapacitance OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop length estimate will be based on tip-ring
capacitance measurement. User will be able to specify
the loop length multiplier. If not supplied, loop length
multiplier of 83 nF/ mile will be used. This test will
not be available if fuse test fails or alarm is present.
This test is intrusive and will be available in shutdown
state only. "
::= { mltLoopLengthResultsEntry 2 }
mltLoopLengthLoopLength OBJECT-TYPE
SYNTAX Integer32
UNITS "ft"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop length estimate will be based on tip-ring
capacitance measurement. User will be able to specify
the loop length multiplier. If not supplied, loop length
multiplier of 83 nF/ mile will be used. This test will
not be available if fuse test fails or alarm is present.
This test is intrusive and will be available in shutdown
state only. "
::= { mltLoopLengthResultsEntry 3 }
mltLoopLengthUncompensatedLoopCapacitance OBJECT-TYPE
SYNTAX Integer32
UNITS "nF"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop length estimate will be based on tip-ring
capacitance measurement. User will be able to specify
the loop length multiplier. If not supplied, loop length
multiplier of 83 nF/ mile will be used. This test will
not be available if fuse test fails or alarm is present.
This test is intrusive and will be available in shutdown
state only. This value has no DSL correction."
::= { mltLoopLengthResultsEntry 4 }
mltLoopLengthUncompensatedLoopLength OBJECT-TYPE
SYNTAX Integer32
UNITS "ft"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop length estimate will be based on tip-ring
capacitance measurement. User will be able to specify
the loop length multiplier. If not supplied, loop length
multiplier of 83 nF/ mile will be used. This test will
not be available if fuse test fails or alarm is present.
This test is intrusive and will be available in shutdown
state only. This value has no DSL correction."
::= { mltLoopLengthResultsEntry 5 }
mltLoopLengthErrors OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates GNK and/or OTEMP alarms active when test was
run."
::= { mltLoopLengthResultsEntry 6 }
-- notifications
mltTestCompletedNotification NOTIFICATION-TYPE
OBJECTS { mltTestIdentifier, mltTestPort,
mltLastTestStatus, mltErrorText }
STATUS current
DESCRIPTION
"This notification is sent to the
requesting host when the requested mlt
test has completed."
::= { mltTestNotifications 1 }
END
|