1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
|
CAMBIUM-PTP600-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32, IpAddress,
enterprises
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
DisplayString
FROM SNMPv2-TC
InetAddress, InetAddressType
FROM INET-ADDRESS-MIB;
cambium MODULE-IDENTITY
LAST-UPDATED "201403041414Z"
ORGANIZATION "Cambium Networks Ltd."
CONTACT-INFO
"Post: Simon Whitaker
Cambium Networks Ltd.
Unit B2,
Linhay Business Park,
Eastern Road,
Ashburton,
Devon.
TQ13 7UP
United Kingdom
Phone: +44 (0) 1364 655 500
Email: simon.whitaker@cambiumnetworks.com"
DESCRIPTION
"MIB for 300Mbps non-line-of-sight (NLOS) wireless ethernet bridge."
REVISION "201403041414Z"
DESCRIPTION
"PTP600-10-07:
Reinstated incompatibleRegionCodesTrap.
Reinstated incompatibleMasterAndSlaveTrap.
Reinstated encryptionEnabledMismatchTrap."
REVISION "201309142338Z"
DESCRIPTION
"PTP600-10-06:
Removed incompatibleRegionCodesTrap.
Removed incompatibleMasterAndSlaveTrap.
Removed encryptionEnabledMismatchTrap."
REVISION "201208131812Z"
DESCRIPTION
"PTP600-10-04:
Added ethernetBridgingStatus, ethernetBridgingAvailability.
Added ethernetBridgingStatusAlarm, ethernetBridgingStatusAlarmTrap."
REVISION "201205011158Z"
DESCRIPTION
"PTP600-10-03: make linkName & groupID read-write."
REVISION "201202131238Z"
DESCRIPTION
"PTP600-10-01: Updated ORGANIZATION and CONTACT-INFO."
REVISION "201111081347Z"
DESCRIPTION
"PTP600-10-00:
Added new SNTP attributes, replace syslogLocalLog with syslogState. Add L2/L3 QoS attributes.
Added securityLevel. Renamed vLANPriorityQueueMapping with ethernetPriorityQueueMapping.
Added syslogClient and secureModeAlarm traps."
REVISION "201012071328Z"
DESCRIPTION "PTP600-09-10: Added searchState, accessMethod and groupID."
REVISION "201011021333Z"
DESCRIPTION "PTP600-09-02: Added latitude, longitude, altitude."
REVISION "201007161541Z"
DESCRIPTION
"PTP600-09-01:
Changed root OID.
Renamed ethernet & fiber attributes & traps.
Replaced vLANManagementVIDValidation with managementMode.
Added linkName, siteName, hTTPSAccessEnabled, tDDSynchronizationMode.
Added syslog attributes & traps.
Added SNMPTrapTable for dual trap receivers."
REVISION "201004231007Z"
DESCRIPTION "PTP600-08-50: Security enhancements."
REVISION "201002191855Z"
DESCRIPTION "PTP600-08-04: Added SNMPv3 support, DFS Table, Automatic Tx Power Control. BIT STRING types now OCTET STRING."
REVISION "200907101520Z"
DESCRIPTION "PTP600-08-03: Added VLAN Priority Table, more read-only attributes, plus alarm tidy-up."
REVISION "200902271711Z"
DESCRIPTION "PTP600-08-01: Improve TDD Synchronization status and alarms."
REVISION "200812151219Z"
DESCRIPTION "PTP600-08-00: Support 4.8 & 4.9 GHz variant & 20 MHz bandwidth, Link Symmetry, TDD Synchronization."
REVISION "200806301016Z"
DESCRIPTION "PTP600-07-00: Added IEEE 802.1q & 802.1ad VLAN support."
REVISION "200802290942Z"
DESCRIPTION "PTP600-06-00: Added OOB, HTTP & telnet access controls."
REVISION "200707311839Z"
DESCRIPTION "PTP600-05-00: Added groups, attributes and notifications for diagnostic alarms."
REVISION "200611231436Z"
DESCRIPTION "PTP600-04-00: Converted to SMIv2."
REVISION "200607241008Z"
DESCRIPTION "PTP600-03-01"
::= { enterprises 17713 }
-- Groups in cambium
ptp OBJECT IDENTIFIER ::= { cambium 1 }
ptmp OBJECT IDENTIFIER ::= { cambium 2 }
ptp600 OBJECT IDENTIFIER ::= { cambium 6 }
-- Groups in ptp600
dfs OBJECT IDENTIFIER ::= { ptp600 3 }
bridge OBJECT IDENTIFIER ::= { ptp600 4 }
configuration OBJECT IDENTIFIER ::= { ptp600 5 }
ethernet OBJECT IDENTIFIER ::= { ptp600 6 }
telecom OBJECT IDENTIFIER ::= { ptp600 7 }
licence OBJECT IDENTIFIER ::= { ptp600 8 }
management OBJECT IDENTIFIER ::= { ptp600 9 }
phyControl OBJECT IDENTIFIER ::= { ptp600 10 }
phyStatus OBJECT IDENTIFIER ::= { ptp600 12 }
alarms OBJECT IDENTIFIER ::= { ptp600 13 }
smtp OBJECT IDENTIFIER ::= { ptp600 15 }
snmpControl OBJECT IDENTIFIER ::= { ptp600 16 }
sntp OBJECT IDENTIFIER ::= { ptp600 17 }
reset OBJECT IDENTIFIER ::= { ptp600 18 }
versions OBJECT IDENTIFIER ::= { ptp600 19 }
pubStats OBJECT IDENTIFIER ::= { ptp600 20 }
encryption OBJECT IDENTIFIER ::= { ptp600 22 }
tDDControl OBJECT IDENTIFIER ::= { ptp600 23 }
aAAControl OBJECT IDENTIFIER ::= { ptp600 25 }
syslogControl OBJECT IDENTIFIER ::= { ptp600 24 }
supplementary OBJECT IDENTIFIER ::= { ptp600 96 }
ptpGroups OBJECT IDENTIFIER ::= { ptp600 98 }
ptpTraps OBJECT IDENTIFIER ::= { ptp600 99 }
ptpTrapPrefix OBJECT IDENTIFIER ::= { ptpTraps 0 }
-- Compliance information
--
ptpCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the Cambium PTP MIB"
MODULE -- this module
MANDATORY-GROUPS { dfsGroup
, bridgeGroup
, configurationGroup
, ethernetGroup
, telecomGroup
, licenceGroup
, managementGroup
, phyControlGroup
, phyStatusGroup
, alarmsGroup
, smtpGroup
, snmpControlGroup
, sntpGroup
, resetGroup
, versionsGroup
, pubStatsGroup
, encryptionGroup
, tDDControlGroup
, aAAControlGroup
, syslogControlGroup
, supplementaryGroup
, notificationsGroup
}
::= { ptp600 97 }
dfsGroup OBJECT-GROUP
OBJECTS { dfsTableNumber
, dfsMeans
, dfsNineNinePointNinePercentiles
, dfsPeaks
}
STATUS current
DESCRIPTION "The dfs object group."
::= { ptpGroups 3 }
bridgeGroup OBJECT-GROUP
OBJECTS { localPacketFiltering
}
STATUS current
DESCRIPTION "The bridge object group."
::= { ptpGroups 4 }
configurationGroup OBJECT-GROUP
OBJECTS { iPv4Address
, subnetMask
, gatewayIPAddress
, targetMACAddress
, masterSlaveMode
, maximumTransmitPower
, antennaGain
, cableLoss
, eIRP
, ethernetCappedMaxWirelessSpeed
, channelBandwidth
, remoteIPAddress
, linkName
, siteName
, accessMethod
, groupID
, iPv6Address
, iPVersion
, iPv6AutoConfiguredLinkLocalAddress
, iPv6PrefixLength
, iPv6GatewayAddress
, remoteInternetAddressType
, remoteInternetAddress
}
STATUS current
DESCRIPTION "The configuration object group."
::= { ptpGroups 5 }
ethernetGroup OBJECT-GROUP
OBJECTS { dataPortAutoNegotiation
, dataPortAutoNegAdvertisement
, dataPortAutoMdix
, dataPortStatus
, dataPortSpeedAndDuplex
, dataPortWirelessDownAlert
, useVLANForManagementInterfaces
, vLANManagementPriority
, vLANManagementVID
, managementPortStatus
, managementPortSpeedAndDuplex
, ethernetPriorityTableNumber
, l2CPPriorityTableNumber
, iPDSCPPriorityTableNumber
, mPLSTCPriorityTableNumber
, managementMode
, managementPortWirelessDownAlert
, qOSPriorityScheme
, unknownNetworkPriorityQueueMapping
, dSCPManagementPriority
, ethernetBridgingStatus
, ethernetPriorityQueueMapping
, l2CPPriorityQueueMapping
, iPDSCPPriorityQueueMapping
, mPLSTCPriorityQueueMapping
}
STATUS current
DESCRIPTION "The ethernet object group."
::= { ptpGroups 6 }
telecomGroup OBJECT-GROUP
OBJECTS { telecomsInterface
, telecomsChannelAStatus
, telecomsChannelBStatus
, channelALineCode
, channelBLineCode
, channelACableLength
, channelBCableLength
, channelALoopback
, channelBLoopback
, telecomsChannelSelection
}
STATUS current
DESCRIPTION "The telecom object group."
::= { ptpGroups 7 }
licenceGroup OBJECT-GROUP
OBJECTS { regionCode
, productVariant
, productName
, ethernetFiberSupport
, frequencyVariant
, bandwidthVariant
, constantPowerSpectralDensity
, sNMPv3Enable
, hAZLOCConfiguration
, securityLevel
}
STATUS current
DESCRIPTION "The licence object group."
::= { ptpGroups 8 }
managementGroup OBJECT-GROUP
OBJECTS { targetRange
, rangingMode
, installStatus
, installArmState
, tFTPServerIPAddress
, tFTPServerPortNumber
, tFTPSoftwareUpgradeFileName
, tFTPStartSoftwareUpgrade
, tFTPSoftwareUpgradeStatus
, tFTPSoftwareUpgradeStatusText
, tFTPSoftwareUpgradeStatusAdditionalText
, hTTPAccessEnabled
, telnetAccessEnabled
, hTTPPortNumber
, hTTPSPortNumber
, telnetPortNumber
, hTTPSAccessEnabled
, tFTPServerInternetAddressType
, tFTPServerInternetAddress
}
STATUS current
DESCRIPTION "The management object group."
::= { ptpGroups 9 }
phyControlGroup OBJECT-GROUP
OBJECTS { linkSymmetry
, linkModeOptimisation
, userConfiguredMaxModulationMode
, remoteMaximumTransmitPower
, txColorCode
, rxColorCode
, automaticTxPowerControl
, remoteRxTargetPower
}
STATUS current
DESCRIPTION "The phyControl object group."
::= { ptpGroups 10 }
phyStatusGroup OBJECT-GROUP
OBJECTS { receivePower
, vectorError
, transmitPower
, range
, linkLoss
, receiveChannel
, transmitChannel
, receiveModulationMode
, transmitModulationMode
, receiveFreqMHz
, transmitFreqMHz
, signalStrengthRatio
, receiveFreqKHz
, transmitFreqKHz
, searchState
, rawReceivePower
}
STATUS current
DESCRIPTION "The phyStatus object group."
::= { ptpGroups 12 }
alarmsGroup OBJECT-GROUP
OBJECTS { unitOutOfCalibration
, incompatibleRegionCodes
, noWirelessChannelAvailable
, wirelessLinkDisabledWarning
, dataPortDisabledWarning
, dataPortFiberStatus
, dataPortConfigurationMismatch
, incompatibleMasterAndSlave
, tDDSynchronizationStatus
, managementPortDisabledWarning
, tDDSynchronizationAlarm
, linkModeOptimizationMismatch
, managementPortConfigurationMismatch
, secureModeAlarm
, ethernetBridgingStatusAlarm
}
STATUS current
DESCRIPTION "The alarms object group."
::= { ptpGroups 13 }
smtpGroup OBJECT-GROUP
OBJECTS { sMTPEmailAlert
, sMTPServerIPAddress
, sMTPServerPortNumber
, sMTPSourceEmailAddress
, sMTPDestinationEmailAddress
, sMTPEnabledMessages
, sMTPServerInternetAddressType
, sMTPServerInternetAddress
}
STATUS current
DESCRIPTION "The smtp object group."
::= { ptpGroups 15 }
snmpControlGroup OBJECT-GROUP
OBJECTS { sNMPPortNumber
, sNMPCommunityString
, sNMPTrapTableNumber
, sNMPTrapVersion
, sNMPEnabledTraps
, enabledDiagnosticAlarms
, sNMPSendAllTrapsAtStartup
, sNMPTrapIPAddress
, sNMPTrapPortNumber
, sNMPTrapInternetAddressType
, sNMPTrapInternetAddress
, sNMPTrapReceiverEnabled
}
STATUS current
DESCRIPTION "The snmpControl object group."
::= { ptpGroups 16 }
sntpGroup OBJECT-GROUP
OBJECTS { sNTPState
, sNTPPollInterval
, sNTPSync
, sNTPLastSync
, systemClock
, timeZone
, daylightSaving
, sNTPPrimaryServer
, sNTPPrimaryServerDeadTime
, sNTPServerRetries
, sNTPServerTimeout
, sNTPServerTableNumber
, sNTPServerIPAddress
, sNTPServerPortNumber
, sNTPServerStatus
, sNTPServerInternetAddressType
, sNTPServerInternetAddress
}
STATUS current
DESCRIPTION "The sntp object group."
::= { ptpGroups 17 }
resetGroup OBJECT-GROUP
OBJECTS { systemReset
}
STATUS current
DESCRIPTION "The reset object group."
::= { ptpGroups 18 }
versionsGroup OBJECT-GROUP
OBJECTS { softwareVersion
, hardwareVersion
, secondarySoftwareVersion
, bootVersion
}
STATUS current
DESCRIPTION "The versions object group."
::= { ptpGroups 19 }
pubStatsGroup OBJECT-GROUP
OBJECTS { receiveDataRate
, transmitDataRate
, aggregateDataRate
, wirelessLinkAvailability
, wirelessLinkStatus
, byteErrorRatio
, receiveModulationModeDetail
, ethernetBridgingAvailability
}
STATUS current
DESCRIPTION "The pubStats object group."
::= { ptpGroups 20 }
encryptionGroup OBJECT-GROUP
OBJECTS { encryptionAlgorithm
}
STATUS current
DESCRIPTION "The encryption object group."
::= { ptpGroups 22 }
tDDControlGroup OBJECT-GROUP
OBJECTS { tDDSynchronizationMode
}
STATUS current
DESCRIPTION "The tDDControl object group."
::= { ptpGroups 23 }
aAAControlGroup OBJECT-GROUP
OBJECTS { userTableNumber
, userName
, userRole
, userEnabled
, userPassword
}
STATUS current
DESCRIPTION "The aAAControl object group."
::= { ptpGroups 25 }
syslogControlGroup OBJECT-GROUP
OBJECTS { syslogClient
, syslogState
}
STATUS current
DESCRIPTION "The syslogControl object group."
::= { ptpGroups 24 }
supplementaryGroup OBJECT-GROUP
OBJECTS { longitude
, latitude
, altitude
}
STATUS current
DESCRIPTION "The supplementary object group."
::= { ptpGroups 96 }
notificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS { channelChangeTrap
, dfsImpulsiveInterferenceTrap
, dataPortStatusTrap
, telecomsChannelAStatusTrap
, telecomsChannelBStatusTrap
, channelALoopbackTrap
, channelBLoopbackTrap
, regionCodeTrap
, installStatusTrap
, installArmStateTrap
, unitOutOfCalibrationTrap
, incompatibleRegionCodesTrap
, noWirelessChannelAvailableTrap
, wirelessLinkDisabledWarningTrap
, dataPortDisabledWarningTrap
, dataPortFiberStatusTrap
, dataPortConfigurationMismatchTrap
, incompatibleMasterAndSlaveTrap
, sNTPSyncTrap
, tDDSynchronizationAlarmTrap
, managementPortStatusTrap
, managementPortDisabledWarningTrap
, linkModeOptimizationMismatchTrap
, managementPortConfigurationMismatchTrap
, syslogStateTrap
, syslogLocalNearlyFullTrap
, syslogLocalWrappedTrap
, syslogClientTrap
, secureModeAlarmTrap
, ethernetBridgingStatusAlarmTrap
}
STATUS current
DESCRIPTION "The notifications group."
::= { ptpGroups 99 }
DfsTableEntry ::=
SEQUENCE { dfsTableIndex INTEGER
, dfsMeans Integer32
, dfsNineNinePointNinePercentiles Integer32
, dfsPeaks Integer32
}
dfsTable OBJECT-TYPE
SYNTAX SEQUENCE OF DfsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A table storing a snapshot of various DFS measurements for each channel"
::= { dfs 2 }
dfsTableEntry OBJECT-TYPE
SYNTAX DfsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table DfsTable"
INDEX { dfsTableIndex }
::= { dfsTable 1 }
EthernetPriorityTableEntry ::=
SEQUENCE { ethernetPriorityTableIndex INTEGER
, ethernetPriorityQueueMapping INTEGER
}
ethernetPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthernetPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A priority queue mapping table. This is a list of packet queues indexed by Ethernet priority."
::= { ethernet 15 }
ethernetPriorityTableEntry OBJECT-TYPE
SYNTAX EthernetPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table EthernetPriorityTable"
INDEX { ethernetPriorityTableIndex }
::= { ethernetPriorityTable 1 }
L2CPPriorityTableEntry ::=
SEQUENCE { l2CPPriorityTableIndex INTEGER
, l2CPPriorityQueueMapping INTEGER
}
l2CPPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF L2CPPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A priority queue mapping table. This is a list of packet queues indexed by L2CP priority."
::= { ethernet 17 }
l2CPPriorityTableEntry OBJECT-TYPE
SYNTAX L2CPPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table L2CPPriorityTable"
INDEX { l2CPPriorityTableIndex }
::= { l2CPPriorityTable 1 }
IPDSCPPriorityTableEntry ::=
SEQUENCE { iPDSCPPriorityTableIndex INTEGER
, iPDSCPPriorityQueueMapping INTEGER
}
iPDSCPPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF IPDSCPPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A priority queue mapping table. This is a list of packet queues indexed by L3 IP DSCP priority."
::= { ethernet 19 }
iPDSCPPriorityTableEntry OBJECT-TYPE
SYNTAX IPDSCPPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table IPDSCPPriorityTable"
INDEX { iPDSCPPriorityTableIndex }
::= { iPDSCPPriorityTable 1 }
MPLSTCPriorityTableEntry ::=
SEQUENCE { mPLSTCPriorityTableIndex INTEGER
, mPLSTCPriorityQueueMapping INTEGER
}
mPLSTCPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF MPLSTCPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A priority queue mapping table. This is a list of priority queues indexed by MPLS TC priority."
::= { ethernet 21 }
mPLSTCPriorityTableEntry OBJECT-TYPE
SYNTAX MPLSTCPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table MPLSTCPriorityTable"
INDEX { mPLSTCPriorityTableIndex }
::= { mPLSTCPriorityTable 1 }
SNMPTrapTableEntry ::=
SEQUENCE { sNMPTrapTableIndex INTEGER
, sNMPTrapIPAddress IpAddress
, sNMPTrapPortNumber INTEGER
, sNMPTrapInternetAddressType INTEGER
, sNMPTrapInternetAddress InetAddress
, sNMPTrapReceiverEnabled INTEGER
}
sNMPTrapTable OBJECT-TYPE
SYNTAX SEQUENCE OF SNMPTrapTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" SNMP trap configuration table."
::= { snmpControl 4 }
sNMPTrapTableEntry OBJECT-TYPE
SYNTAX SNMPTrapTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table SNMPTrapTable"
INDEX { sNMPTrapTableIndex }
::= { sNMPTrapTable 1 }
SNTPServerTableEntry ::=
SEQUENCE { sNTPServerTableIndex INTEGER
, sNTPServerIPAddress IpAddress
, sNTPServerPortNumber INTEGER
, sNTPServerStatus DisplayString
, sNTPServerInternetAddressType INTEGER
, sNTPServerInternetAddress InetAddress
}
sNTPServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF SNTPServerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { sntp 15 }
sNTPServerTableEntry OBJECT-TYPE
SYNTAX SNTPServerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table SNTPServerTable"
INDEX { sNTPServerTableIndex }
::= { sNTPServerTable 1 }
UserTableEntry ::=
SEQUENCE { userTableIndex INTEGER
, userName OCTET STRING
, userRole INTEGER
, userEnabled INTEGER
, userPassword OCTET STRING
}
userTable OBJECT-TYPE
SYNTAX SEQUENCE OF UserTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The User Table Control group contains objects specifically for user account management."
::= { aAAControl 2 }
userTableEntry OBJECT-TYPE
SYNTAX UserTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table UserTable"
INDEX { userTableIndex }
::= { userTable 1 }
-- Dfs group attribute definitions
--
dfsTableNumber OBJECT-TYPE
SYNTAX INTEGER (1..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the dfsTable"
::= { dfs 1 }
-- DfsTable group attribute definitions
--
dfsTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"used to index values in the dfsTable."
::= { dfsTableEntry 1 }
dfsMeans OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Snapshot of DFS means"
::= { dfsTableEntry 2 }
dfsNineNinePointNinePercentiles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Snapshot of DFS 99.9 percentiles"
::= { dfsTableEntry 3 }
dfsPeaks OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Snapshot of DFS peaks"
::= { dfsTableEntry 4 }
-- Bridge group attribute definitions
--
localPacketFiltering OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Local Packet Filtering is Enabled, the bridge
learns the source MAC addresses of devices transmitting
Ethernet packets on the local Ethernet network, and only
bridges packets to the remote unit if the destination MAC
address has not been learnt as a 'local' device. When
Local Packet Filtering is Disabled then the bridge does
not learn the source MAC addresses of devices
transmitting Ethernet packets on the local Ethernet
network, and bridges ALL Ethernet packets received to the
remote unit. Local Packet Filtering should be enabled if
no external routing hardware is present"
::= { bridge 1 }
-- Configuration group attribute definitions
--
iPv4Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Internet protocol (IPv4) address. This address is used
by the family of Internet protocols to uniquely identify
the unit on a network. NB: A system reboot is required to
activate changes to this attribute."
::= { configuration 1 }
subnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A subnet allows the flow of network traffic between
hosts to be segregated based on a network configuration.
By organizing hosts into logical groups, subnetting can
improve network security and performance. NB: A system
reboot is required to activate changes to this attribute"
::= { configuration 2 }
gatewayIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv4 address of a computer on the current network
that is currently acting as an IPv4 network gateway. A
gateway acts as an entrance / exit to packets from / to
other networks. NB: A system reboot is required to
activate changes to this attribute"
::= { configuration 3 }
targetMACAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the PTP wireless unit forming the other
end of the PTP link"
::= { configuration 4 }
masterSlaveMode OBJECT-TYPE
SYNTAX INTEGER {
master(0),
slave(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The PTP wireless link operates using a master and slave
relationship"
::= { configuration 5 }
maximumTransmitPower OBJECT-TYPE
SYNTAX INTEGER (-15..27)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum transmit power the wireless unit is permitted to
use when establishing and maintaining the wireless link"
::= { configuration 6 }
antennaGain OBJECT-TYPE
SYNTAX INTEGER (0..610)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Antenna Gain. Expressed in 10ths of dBi. NB: This
attribute is ignored for variants with an integral
antenna."
::= { configuration 7 }
cableLoss OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Loss in the cable between the ODU and the antenna.
Expressed in 10ths of dB. NB: This attribute is ignored
for variants with an integral antenna."
::= { configuration 8 }
eIRP OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Effective Isotropic Radiated Power (EIRP) describes the
strength of the radio signal leaving the wireless unit.
Expressed in 10ths of dBm"
::= { configuration 9 }
ethernetCappedMaxWirelessSpeed OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet frames will be discarded in the ODU if the data
rate over the wireless link exceeds the Ethernet link
speed at the local or remote Data port. The Ethernet
Capped Max Wireless Speed control limits the wireless
data rate based on the local and remote Ethernet link
speed. Set this control to Enabled if either ODU is
connected to an Ethernet link operating at less than 1000
Mbps. NB: This attribute is automatically disabled when
the installation agent is armed. To disarm the
installation agent use the installation wizard."
::= { configuration 10 }
channelBandwidth OBJECT-TYPE
SYNTAX INTEGER {
bw30MHz(0),
bw15MHz(1),
bw10MHz(2),
bw5MHz(3),
bw20MHz(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This control sets the bandwidth of the transmit and
receive radio channels"
::= { configuration 11 }
remoteIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP Address of the peer wireless unit"
::= { configuration 12 }
linkName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of the PTP link allocated by the System
Administrator. Used to establish a connection with the
correct PTP wireless unit at the other end of the link.
NOTE: The link name MUST be the same at both ends of the
PTP link."
::= { configuration 14 }
siteName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field contains a user-provided description of the
site name together with any additional notes"
::= { configuration 15 }
accessMethod OBJECT-TYPE
SYNTAX INTEGER {
linkAccess(0),
linkNameAccess(1),
groupAccess(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODUs must be configured in pairs before a link can be
established. The Access Method attribute determines how
the paired ODUs will recognise each other. For the Link
Access method, each ODU must be configured with Target
MAC Address equal to the MAC Address of the other unit.
For the Link Name Access method, both units must be
configured with the same Link Name. For the Group Access
method, both units must be configured with the same Group
ID."
::= { configuration 16 }
groupID OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Access Method is set to Group Access, the Group ID
identifies all the units belonging to the same group"
::= { configuration 17 }
iPv6Address OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..39))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Internet protocol (IPv6) address. This address is used
by the family of Internet protocols to uniquely identify
the unit on a network. NB: A system reboot is required to
activate changes to this attribute."
::= { configuration 18 }
iPVersion OBJECT-TYPE
SYNTAX INTEGER {
iPv4(0),
iPv6(1),
dualIPv4andIPv6(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP protocol selection. Choice of IPv4, IPv6 or Dual."
::= { configuration 20 }
iPv6AutoConfiguredLinkLocalAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..39))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auto configured link local IPv6 address"
::= { configuration 21 }
iPv6PrefixLength OBJECT-TYPE
SYNTAX INTEGER (0..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IPv6 prefix length"
::= { configuration 22 }
iPv6GatewayAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..39))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv6 address of a computer on the current network
that is currently acting as an IPv6 network gateway. A
gateway acts as an entrance / exit to packets from / to
other networks. Note that it is usual to use the
link-local address of the gateway. NB: A system reboot is
required to activate changes to this attribute"
::= { configuration 23 }
remoteInternetAddressType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ipv4(1),
ipv6(2),
ipv4z(3),
ipv6z(4),
unknown6(5),
unknown7(6),
unknown8(7),
unknown9(8),
unknown10(9),
unknown11(10),
unknown12(11),
unknown13(12),
unknown14(13),
unknown15(14),
unknown16(15),
dns(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet address specified by the associated
remoteInternetAddressType."
::= { configuration 24 }
remoteInternetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"INET address used to identify the peer wireless unit"
::= { configuration 25 }
-- Ethernet group attribute definitions
--
dataPortAutoNegotiation OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether the local Ethernet interface
configuration is automatically negotiated or forced. Do
not use a forced setting together with auto negotiation
at the Ethernet link partner. If you want to run your
Ethernet link at a fixed speed and duplex then you would
normally leave auto negotiation enabled and only enable
the single Auto Neg Advertisement option that you want
the link to run in - FORCING ETHERNET CONFIGURATION IS A
LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE
HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST
ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET
LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE
LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED
EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The
new setting will only take effect after a system reboot."
::= { ethernet 1 }
dataPortAutoNegAdvertisement OBJECT-TYPE
SYNTAX BITS {
negInvalid(2),
neg10MbpsHalfDuplex(3),
neg10MbpsFullDuplex(4),
neg100MbpsHalfDuplex(5),
neg100MbpsFullDuplex(6),
neg1000MbpsFullDuplex(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This sets the different Ethernet configurations that
will be advertised during auto negotiation. Note the new
setting will only take effect after a system reboot.
WARNING: Duplex mismatch may result if both ends of the
Ethernet link do not have the same settings. Do not auto
negotiation together with a fixed setting at the Ethernet
link partner. WARNING: Make sure that you select
option(s) that you know your connected equipment can
cater for!"
::= { ethernet 2 }
dataPortAutoMdix OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This enables/disables the Auto MDI/MDIX capability. NB:
The new setting will only take effect after a system
reboot"
::= { ethernet 3 }
dataPortStatus OBJECT-TYPE
SYNTAX INTEGER {
down(0),
copperLinkUp(1),
fiberLinkUp(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the Ethernet link. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ethernet 4 }
dataPortSpeedAndDuplex OBJECT-TYPE
SYNTAX INTEGER {
speed1000MbpsFullDuplex(0),
speed100MbpsFullDuplex(1),
speed100MbpsHalfDuplex(2),
speed10MbpsFullDuplex(3),
speed10MbpsHalfDuplex(4),
speedUnknown6(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current speed and duplex of the Ethernet link"
::= { ethernet 5 }
dataPortWirelessDownAlert OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled, this causes the Ethernet link to be
dropped briefly when the wireless link drops. This is so
that spanning tree algorithms can quickly detect that
there is a problem."
::= { ethernet 6 }
useVLANForManagementInterfaces OBJECT-TYPE
SYNTAX INTEGER {
noVLANTagging(0),
iEEE8021QTaggedCTagType8100(1),
iEEE8021adTaggedSTagorBTagType88a8(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether the management interfaces
(WWW/SNMP/SMTP/SNTP) use VLAN tags or not. NB: The new
setting will only take effect after a system reboot"
::= { ethernet 7 }
vLANManagementPriority OBJECT-TYPE
SYNTAX INTEGER {
p0(0),
p1(1),
p2(2),
p3(3),
p4(4),
p5(5),
p6(6),
p7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This VLAN Priority (0-7) will be included in packets
generated by the management interfaces. NB: The new
setting will only take effect after a system reboot"
::= { ethernet 8 }
vLANManagementVID OBJECT-TYPE
SYNTAX INTEGER (0..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This VLAN VID (0-4094) will be included in packets
generated by the management interfaces. Note the new
setting will only take effect after a system reboot"
::= { ethernet 11 }
managementPortStatus OBJECT-TYPE
SYNTAX INTEGER {
down(0),
copperLinkUp(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the out-of-band management link. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { ethernet 12 }
managementPortSpeedAndDuplex OBJECT-TYPE
SYNTAX INTEGER {
speed100MbpsFullDuplex(1),
speed100MbpsHalfDuplex(2),
speed10MbpsFullDuplex(3),
speed10MbpsHalfDuplex(4),
speedUnknown6(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current speed and duplex of the out-of-band
management link"
::= { ethernet 13 }
ethernetPriorityTableNumber OBJECT-TYPE
SYNTAX INTEGER (9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the vLANPriorityTable."
::= { ethernet 14 }
l2CPPriorityTableNumber OBJECT-TYPE
SYNTAX INTEGER (5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the l2CPPriorityTable."
::= { ethernet 16 }
iPDSCPPriorityTableNumber OBJECT-TYPE
SYNTAX INTEGER (64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the iPDSCPPriorityTable."
::= { ethernet 18 }
mPLSTCPriorityTableNumber OBJECT-TYPE
SYNTAX INTEGER (8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the mPLSTCPriorityTable."
::= { ethernet 20 }
managementMode OBJECT-TYPE
SYNTAX INTEGER {
outofBandLocal(0),
outofBand(1),
inBand(2),
inBandLocal(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Out-of-Band Management (only available on certain
hardware models): End-to-end out-of-band mode in which
the management agent can be reached from the management
port at the local ODU and (assuming that the wireless
link is established) the management port at the remote
ODU. Out-of-Band Local Management (only available on
certain hardware models): Similar to the standard
Out-of-Band mode, except that management frames are not
forwarded over the wireless link. In-Band Management
(default): The management agent can be reached from the
data port at the local ODU and (assuming that the
wireless link is established) the data port at the remote
ODU. In this mode the management port is disabled.
In-Band Local Management (only available when 'Use VLAN
For Management Interfaces' configures a VLAN tag):
Similar to the standard In-Band mode, except that
management frames are not forwarded over the wireless
link."
::= { ethernet 22 }
managementPortWirelessDownAlert OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When enabled, this causes the management link to be
dropped briefly when the wireless link drops. This is so
that spanning tree algorithms can quickly detect that
there is a problem."
::= { ethernet 23 }
qOSPriorityScheme OBJECT-TYPE
SYNTAX INTEGER {
ethernet(0),
iPMPLS(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects classification based on fields in the Ethernet
header (Layer 2) or in the Network header (Layer 3). The
unit recognises two network layer protocols: IP and MPLS"
::= { ethernet 24 }
unknownNetworkPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of unknown network
protocols to an egress queue at the wireless port.
Unknown means something other than IP and MPLS"
::= { ethernet 25 }
dSCPManagementPriority OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This Differentiated Services Code Point value will be
inserted in the IP Header of all IP Datagrams transmitted
by the management interfaces"
::= { ethernet 26 }
ethernetBridgingStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of Ethernet packet bridging over the
wireless link"
::= { ethernet 27 }
-- EthernetPriorityTable group attribute definitions
--
ethernetPriorityTableIndex OBJECT-TYPE
SYNTAX INTEGER {
p0(1),
p1(2),
p2(3),
p3(4),
p4(5),
p5(6),
p6(7),
p7(8),
untagged(9)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ethernet priority flag, used to index values in the
ethernetPriorityTable"
::= { ethernetPriorityTableEntry 1 }
ethernetPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of this Ethernet priority
(also known as IEEE 802.1p value) to an egress queue at
the wireless port"
::= { ethernetPriorityTableEntry 2 }
-- L2CPPriorityTable group attribute definitions
--
l2CPPriorityTableIndex OBJECT-TYPE
SYNTAX INTEGER {
bridge(1),
mRP(2),
cFM(3),
rAPS(4),
eAPS(5)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"L2CP priority flag, used to index values in the
l2CPPriorityTable"
::= { l2CPPriorityTableEntry 1 }
l2CPPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of this layer two control
protocol (L2CP) to an egress queue at the wireless port"
::= { l2CPPriorityTableEntry 2 }
-- IPDSCPPriorityTable group attribute definitions
--
iPDSCPPriorityTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IP DSCP priority flag, used to index values in the
iPDSCPPriorityTable"
::= { iPDSCPPriorityTableEntry 1 }
iPDSCPPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of this IP differentiated
services code point (DSCP) value to an egress queue at
the wireless port"
::= { iPDSCPPriorityTableEntry 2 }
-- MPLSTCPriorityTable group attribute definitions
--
mPLSTCPriorityTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MPLS TC priority flag, used to index values in the
mPLSTCPriorityTable"
::= { mPLSTCPriorityTableEntry 1 }
mPLSTCPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of this MPLS traffic class
(the field formerly known as EXP) to an egress queue at
the wireless port"
::= { mPLSTCPriorityTableEntry 2 }
-- Telecom group attribute definitions
--
telecomsInterface OBJECT-TYPE
SYNTAX INTEGER {
none(0),
e1(1),
t1(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line interface type. If this is set to 'None' then
the telecoms interfaces are disabled, and the telecom
group attributes will be ignored."
::= { telecom 1 }
telecomsChannelAStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
noSignalLocal(1),
noSignalRemote(2),
noSignalLocalandRemote(3),
up(4),
remoteTiming(5),
noSignalLocalandRemoteTiming(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of telecoms channel A. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { telecom 2 }
telecomsChannelBStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
noSignalLocal(1),
noSignalRemote(2),
noSignalLocalandRemote(3),
up(4),
remoteTiming(5),
noSignalLocalandRemoteTiming(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of telecoms channel B. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { telecom 3 }
channelALineCode OBJECT-TYPE
SYNTAX INTEGER {
aMI(0),
b8ZSHDB3(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line code setting of the telecoms interface. This
must match the setting of the device connected to this
interface"
::= { telecom 4 }
channelBLineCode OBJECT-TYPE
SYNTAX INTEGER {
aMI(0),
b8ZSHDB3(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line code setting of the telecoms interface. This
must match the setting of the device connected to this
interface"
::= { telecom 5 }
channelACableLength OBJECT-TYPE
SYNTAX INTEGER {
feet133(0),
feet266(1),
feet399(2),
feet533(3),
feet655(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The length of the cable connected to the telecoms
interface, measured in feet"
::= { telecom 6 }
channelBCableLength OBJECT-TYPE
SYNTAX INTEGER {
feet133(0),
feet266(1),
feet399(2),
feet533(3),
feet655(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The length of the cable connected to the telecoms
interface, measured in feet"
::= { telecom 7 }
channelALoopback OBJECT-TYPE
SYNTAX INTEGER {
none(0),
copper(1),
wireless(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The loopback status of telecoms channel A. This is
intended for installation testing and should be set to
'None' for normal operation. The wire connections to a
unit can be tested by applying a 'Copper' loopback to the
local unit. The wireless connection to the remote unit
can be tested by applying a 'Wireless' loopback to the
remote unit with no loopback on the local unit. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { telecom 8 }
channelBLoopback OBJECT-TYPE
SYNTAX INTEGER {
none(0),
copper(1),
wireless(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The loopback status of telecoms channel B. This is
intended for installation testing and should be set to
'None' for normal operation. The wire connections to a
unit can be tested by applying a 'Copper' loopback to the
local unit. The wireless connection to the remote unit
can be tested by applying a 'Wireless' loopback to the
remote unit with no loopback on the local unit. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { telecom 9 }
telecomsChannelSelection OBJECT-TYPE
SYNTAX INTEGER {
channelAOnly(0),
channelsAandB(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates which telecoms channels have been enabled. If
only Channel A has been enabled, then the Channel B
attributes will be ignored."
::= { telecom 10 }
-- Licence group attribute definitions
--
regionCode OBJECT-TYPE
SYNTAX INTEGER {
regionCodeInvalid(0),
regionCode1(1),
regionCode2(2),
regionCode3(3),
regionCode4(4),
regionCode5(5),
regionCode6(6),
regionCode7(7),
regionCode8(8),
regionCode9(9),
regionCode10(10),
regionCode11(11),
regionCode12(12),
regionCode13(13),
regionCode14(14),
regionCode15(15),
regionCode16(16),
regionCode17(17),
regionCode18(18),
regionCode19(19),
regionCode20(20),
regionCode21(21),
regionCode22(22),
regionCode23(23),
regionCode24(24),
regionCode25(25),
regionCode26(26),
regionCode27(27),
regionCode28(28),
regionCode29(29),
regionCode30(30),
regionCode31(31)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The region code prohibits the wireless unit from
operating outside the regulated limits. An invalid region
code indicates a corrupted license key. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { licence 1 }
productVariant OBJECT-TYPE
SYNTAX INTEGER {
pTPxx400Full(0),
pTPxx400Deprecated1(1),
pTPxx400Deprecated2(2),
pTPxx400Lite(3),
spare1(4),
pTPxx300(5),
spare2(6),
spare3(7),
pTPxx500FullDeprecated(8),
pTPxx500LiteDeprecated(9),
pTPxx500(10),
pTPxx600Lite(11),
pTPxx600Full(12),
spare5(13),
spare6(14),
pTP800(15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The product variant"
::= { licence 2 }
productName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the product variant"
::= { licence 3 }
ethernetFiberSupport OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet fiber support availability on this wireless
unit"
::= { licence 4 }
frequencyVariant OBJECT-TYPE
SYNTAX INTEGER {
freq5800MHz(0),
freq5400MHz(1),
freq4900MHz(2),
freq2500MHz(3),
freq5800MHz2(4),
freq5400MHz2(5),
freq4500MHz(6),
freq5900MHz(7),
freq5200MHz(8),
freq5100MHz(9),
freq4800MHz(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frequency variant of the wireless unit"
::= { licence 5 }
bandwidthVariant OBJECT-TYPE
SYNTAX INTEGER {
bw30MHz(0),
bw15MHz(1),
bw10MHz(2),
bw5MHz(3),
bw20MHz(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bandwidth variant of the wireless unit"
::= { licence 6 }
constantPowerSpectralDensity OBJECT-TYPE
SYNTAX INTEGER {
constant(0),
fullPower(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Constant power spectral density mode control"
::= { licence 7 }
sNMPv3Enable OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SNMPv3 availability control"
::= { licence 9 }
hAZLOCConfiguration OBJECT-TYPE
SYNTAX INTEGER {
nonHAZLOCUnit(0),
gasGroupA(1),
gasGroupB(2),
gasGroupC(3),
gasGroupD(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The HAZLOC/ATEX Configuration of this unit. The Gas
Group is configured by the license key."
::= { licence 10 }
securityLevel OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
fIPS(1),
uCAPL(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum configurable security level"
::= { licence 11 }
-- Management group attribute definitions
--
targetRange OBJECT-TYPE
SYNTAX INTEGER (0..2000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Initial target range used in installation +/-1,
expressed in tenths of a kilometer. When Auto-Ranging
this must be set to 0"
::= { management 1 }
rangingMode OBJECT-TYPE
SYNTAX INTEGER {
auto0to40km(0),
auto0to100km(1),
auto0to200km(2),
targetRange(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of ranging to use during installation, either
Auto-Ranging or use a selectable Target Range"
::= { management 2 }
installStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
wrongPeer(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A non-zero value indicates that signalling was received
with the wrong MAC address or a mismatched link name. NB:
It is very unusual to detect this, because units with
mis-configured Target MAC Address will normally fail to
establish a wireless link. However, rare circumstances
may establish a partial wireless link and detect this
situation. NB: A non-zero value on start-up, or a change
of value during operation, may generate an SNMP trap
and/or SMTP email alert"
::= { management 3 }
installArmState OBJECT-TYPE
SYNTAX INTEGER {
disarmed(0),
armed(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if the unit is being installed. NB: a change
of state may generate an SNMP trap and/or SMTP email
alert"
::= { management 4 }
tFTPServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address of the TFTP Server from which the TFTP
Software Upgrade File Name will be retrieved"
::= { management 5 }
tFTPServerPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port number of the TFTP Server from which the TFTP
Software Upgrade File Name will be retrieved"
::= { management 6 }
tFTPSoftwareUpgradeFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Filename of the Software Upgrade to be loaded from the
TFTP Server"
::= { management 7 }
tFTPStartSoftwareUpgrade OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write '1' to this attribute to start the TFTP software
upgrade process. The attribute will be reset to 0 when
the upgrade process has finished. Continuing with the
software upgrade will cause spectrum management (DSO)
channel metrics collection to stop. The wireless unit
will no longer search for the optimal operational radio
channel. The performance of this wireless link may
deterioate over time. If operating in a region where
RADAR detection is mandatory you must complete the
software upgrade and reboot the unit. Channel metrics
collection will only be restarted after the wireless unit
has been rebooted"
::= { management 8 }
tFTPSoftwareUpgradeStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
uploadinprogress(1),
uploadsuccessfulprogrammingFLASH(2),
upgradesuccessfulreboottorunthenewsoftwareimage(3),
upgradefailed(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the TFTP Software upgrade process"
::= { management 9 }
tFTPSoftwareUpgradeStatusText OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Descriptive text describing the status of the TFTP
Software upgrade process, including any error details"
::= { management 10 }
tFTPSoftwareUpgradeStatusAdditionalText OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Any additional text describing the status of the TFTP
Software upgrade process, including any error details"
::= { management 11 }
hTTPAccessEnabled OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether or not HTTP access is enabled,
i.e. if this is disabled (0) then the unit will not
respond to any requests on the HTTP port. Remote
management via HTTPS is not affected by this setting. Any
change in this setting will not take effect until the
unit has been rebooted. (Factory default = Enabled)"
::= { management 12 }
telnetAccessEnabled OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether or not Telnet access is enabled,
i.e. if this is disabled (0) then the unit will not
respond to any requests on the TELNET port. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = Disabled)"
::= { management 13 }
hTTPPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls the port number for HTTP access. A value
of zero will use the default port number. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = 80)"
::= { management 14 }
hTTPSPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls the port number for HTTPS access. A value
of zero will use the default port number. Availability of
HTTPS is controlled via the License Key. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = 443)"
::= { management 15 }
telnetPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls the port number for TELNET access. A value
of zero will use the default port number. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = 23)"
::= { management 16 }
hTTPSAccessEnabled OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether or not HTTPS access is enabled,
i.e. if this is disabled (0) then the unit will not
respond to any requests on the HTTPS port. Remote
management via HTTP is not affected by this setting. Any
change in this setting will not take effect until the
unit has been rebooted. (Factory default = Enabled)"
::= { management 17 }
tFTPServerInternetAddressType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ipv4(1),
ipv6(2),
ipv4z(3),
ipv6z(4),
unknown6(5),
unknown7(6),
unknown8(7),
unknown9(8),
unknown10(9),
unknown11(10),
unknown12(11),
unknown13(12),
unknown14(13),
unknown15(14),
unknown16(15),
dns(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet address specified by the associated
tFTPServerInternetAddress."
::= { management 18 }
tFTPServerInternetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"INET address of the TFTP Server from which the TFTP
Software Upgrade File Name will be retrieved"
::= { management 19 }
-- PhyControl group attribute definitions
--
linkSymmetry OBJECT-TYPE
SYNTAX INTEGER {
symmetryAdaptive(0),
symmetry2to1(1),
symmetry1to1(2),
symmetry1to2(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link Symmetry: in fixed symmetric mode the master spends
an equal amount of time transmitting and receiving; in
fixed asymmetric modes the master transmit and receive
times have a fixed ratio; in adaptive mode the transmit
and receive periods adjust with applied load."
::= { phyControl 1 }
linkModeOptimisation OBJECT-TYPE
SYNTAX INTEGER {
iPTraffic(0),
tDMTraffic(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optimises the wireless link behavior for the type of
traffic to be carried. In 'IP Traffic' mode, the wireless
link will minimise transmission errors by automatically
adapting the modulation mode. In 'TDM Traffic' mode, the
wireless link will minimise transmission latency and
preserve throughput by maintaining a higher modulation
mode in the presence of a limited number of errors. The
'TDM Traffic' mode is recommended for E1/T1 applications
and connectionless protocols."
::= { phyControl 2 }
userConfiguredMaxModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modBpsk63percent(0),
modQpsk63percent(1),
modQpsk87percent(2),
mod16qam63percent(3),
mod16qam87percent(4),
mod64qam75percent(5),
mod64qam92percent(6),
mod256qam81percent(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum receive modulation mode controls the MAX
mode used for adaptive modulation. NOTE: This attribute
is automatically disabled when the installation agent is
armed. To disarm the installation agent use the
installation wizard"
::= { phyControl 3 }
remoteMaximumTransmitPower OBJECT-TYPE
SYNTAX INTEGER (-15..27)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum transmit power the remote wireless unit is
permitted to use when establishing and maintaining the
wireless link"
::= { phyControl 4 }
txColorCode OBJECT-TYPE
SYNTAX INTEGER {
a(0),
b(1),
c(2),
d(3),
e(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmit Color Code. This attribute need only be
considered when the unit is installed in a network of
PTP600 units and where some of the units are operating on
the same frequency. In this case, the value would
normally be derived by a network planner. In all other
cases, it is recommended that this attribute is left at
the default value. NOTE: For the link to operate, the
value of this parameter must in all cases match the value
of the Rx Color Code parameter at the far end of the
link."
::= { phyControl 5 }
rxColorCode OBJECT-TYPE
SYNTAX INTEGER {
a(0),
b(1),
c(2),
d(3),
e(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive Color Code. This attribute need only be
considered when the unit is installed in a network of
PTP600 units and where some of the units are operating on
the same frequency. In this case, the value would
normally be derived by a network planner. In all other
cases, it is recommended that this attribute is left at
the default value. NOTE: For the link to operate, the
value of this parameter must in all cases match the value
of the Tx Color Code parameter at the far end of the
link."
::= { phyControl 6 }
automaticTxPowerControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1),
enabledwithinitialestimate(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When enabled, the transmit power of the local end is
automatically adjusted to maintain a configurable target
receive signal level at the remote end of the link. When
set to Enable with initial estimate, the Slave estimates
the optional transmit power before it responds to the
Master."
::= { phyControl 8 }
remoteRxTargetPower OBJECT-TYPE
SYNTAX INTEGER (-600..-400)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the target receive level for the end of the link
which is remote from the end being configured. When
Automatic Power Control is enabled, the transmit power of
the local end is automatically adjusted in order to
maintain the receive signal level at the remote end
within a range centered on this value"
::= { phyControl 9 }
-- PhyStatus group attribute definitions
--
receivePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive power expressed in tenths of a dBm"
::= { phyStatus 1 }
vectorError OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vector error measurement compares the received
signal's IQ modulation characteristics to an ideal signal
to determine the composite error vector magnitude. The
value represented by this attribute is the average vector
error over the previous second expressed in tenths of a
dB"
::= { phyStatus 2 }
transmitPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmit power expressed in tenths of a dBm"
::= { phyStatus 3 }
range OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Distance between the two peer wireless units expressed
in tenths of a kilometer"
::= { phyStatus 4 }
linkLoss OBJECT-TYPE
SYNTAX INTEGER (-500..500)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The wireless link loss expressed in tenths of a dB"
::= { phyStatus 5 }
receiveChannel OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active receive channel"
::= { phyStatus 6 }
transmitChannel OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active transmit channel"
::= { phyStatus 7 }
receiveModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modAcquisition(0),
modBpsk63percent(1),
modQpsk63percentSingle(2),
modTransient1(3),
modQpsk87percentSingle(4),
modTransient2(5),
mod16qam63percentSingleA(6),
modTransient3(7),
mod16qam87percentSingle(8),
modTransient4(9),
mod64qam75percentSingle(10),
modTransient5(11),
mod64qam92percentSingle(12),
modTransient6(13),
mod256qam81percentSingle(14),
mod16qam63percentSingleB(15),
mod16qam63percentDual(16),
modTransient7(17),
mod16qam87percentDual(18),
modTransient8(19),
mod64qam75percentDual(20),
modTransient9(21),
mod64qam92percentDual(22),
modTransient10(23),
mod256qam81percentDual(24)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active receive modulation mode"
::= { phyStatus 8 }
transmitModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modAcquisition(0),
modBpsk63percent(1),
modQpsk63percentSingle(2),
modTransient1(3),
modQpsk87percentSingle(4),
modTransient2(5),
mod16qam63percentSingleA(6),
modTransient3(7),
mod16qam87percentSingle(8),
modTransient4(9),
mod64qam75percentSingle(10),
modTransient5(11),
mod64qam92percentSingle(12),
modTransient6(13),
mod256qam81percentSingle(14),
mod16qam63percentSingleB(15),
mod16qam63percentDual(16),
modTransient7(17),
mod16qam87percentDual(18),
modTransient8(19),
mod64qam75percentDual(20),
modTransient9(21),
mod64qam92percentDual(22),
modTransient10(23),
mod256qam81percentDual(24)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active transmit modulation mode"
::= { phyStatus 9 }
receiveFreqMHz OBJECT-TYPE
SYNTAX INTEGER (0..5925)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current receive frequency expressed in integer MHz"
::= { phyStatus 11 }
transmitFreqMHz OBJECT-TYPE
SYNTAX INTEGER (0..5925)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current transmit frequency expressed in integer MHz"
::= { phyStatus 12 }
signalStrengthRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal strength ratio (Vertical / Horizontal) : the
number of dB larger the Vertical antenna input is than
the Horizontal antenna input expressed in tenths of a dB"
::= { phyStatus 13 }
receiveFreqKHz OBJECT-TYPE
SYNTAX INTEGER (0..5925000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current receive frequency expressed as KHz"
::= { phyStatus 14 }
transmitFreqKHz OBJECT-TYPE
SYNTAX INTEGER (0..5925000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current transmit frequency expressed as KHz"
::= { phyStatus 15 }
searchState OBJECT-TYPE
SYNTAX INTEGER {
registering(0),
searching(1),
acquiring(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Search status of the wireless modem. 'Registering' means
that the modem has locked to an OFDM signal, and the
wireless link is up. 'Searching' means that no wireless
signal has been detected. 'Acquiring' means that a
wireless signal has been detected, but the modem has not
locked to an OFDM signal."
::= { phyStatus 16 }
rawReceivePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Raw receive power expressed in tenths of a dBm"
::= { phyStatus 17 }
-- Alarms group attribute definitions
--
unitOutOfCalibration OBJECT-TYPE
SYNTAX INTEGER {
calibrated(0),
outOfCalibration(1),
outOfCalibrationPAsShutdown(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit is out of calibration"
::= { alarms 1 }
incompatibleRegionCodes OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
incompatibleLicenceKeys(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The master and slave units have incompatible region
codes. NB: Both units must have compatible license keys"
::= { alarms 4 }
noWirelessChannelAvailable OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
noWirelessChannelAvailable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Spectrum Management was unable to locate a suitable
wireless channel to operate on"
::= { alarms 5 }
wirelessLinkDisabledWarning OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
disabledBySNMPifAdminStatus(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the wireless interface has
disabled wireless traffic"
::= { alarms 6 }
dataPortDisabledWarning OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
disabledBySNMPifAdminStatus(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the Ethernet interface has
disabled Ethernet traffic"
::= { alarms 7 }
dataPortFiberStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
installedFiberNotLicensed(1),
fiberLinkNotEstablishedButLOSNotDetected(2),
fiberLinkNotEstablishedAndLOSDetected(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the fiber link is not OK, there are three possible
causes: Either the fiber link has been installed but
disabled (because the license key does not include fiber
support), the link could not be established even though
no LOS was detected (i.e. an optical carrier was
detected, which could be due to a broken TX fiber, or
because the link is disabled at the fiber link partner),
or the link could not be established and LOS is detected
(i.e. no optical carrier is detected). NB: a change of
status may generate an SNMP trap and/or SMTP email alert"
::= { alarms 8 }
dataPortConfigurationMismatch OBJECT-TYPE
SYNTAX INTEGER {
noError(0),
mismatchDetected(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch"
::= { alarms 9 }
incompatibleMasterAndSlave OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
incompatibleProductVariants(1),
differentSoftwareVersionsRunning(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A non-zero value indicates that the master and slave
ends of a link are different hardware products, or have
different software versions. NB: It is very unusual to
detect this, because incompatible units will normally
fail to establish a wireless link. However, some
combinations may establish a partial wireless link and
detect this situation. NB: A non-zero value may generate
an SNMP trap and/or SMTP email alert"
::= { alarms 10 }
tDDSynchronizationStatus OBJECT-TYPE
SYNTAX INTEGER {
locked(0),
holdover(1),
holdoverNotConnected(2),
acquiringLock(3),
noTimingReference(4),
timingSystemNotConnected(5),
initialising(6),
clusterTimingMaster(7),
tDDSyncNotActive(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An alarm value (displayed in red) indicates that one of
the following conditions has not been met (i) An external
timing system is connected or internal timing has been
configured. (ii) The timing system is providing a useable
reference. (iii) The ODU is locked to this reference."
::= { alarms 11 }
managementPortDisabledWarning OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
disabledBySNMPifAdminStatus(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the out-of-band management
interface has disabled Ethernet traffic"
::= { alarms 12 }
tDDSynchronizationAlarm OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
notSynchronized(1),
timingSystemFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Not Synchronized indicates failure of the external
timing system for a period greater than the holdover
timer. TDD frame timing will have drifted, and this link
may cause interference with other links in a synchronized
network. Timing System Failure is an early warning,
indicating that 80% of the holdover period has expired."
::= { alarms 13 }
linkModeOptimizationMismatch OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
linkModeOptimizationMismatch(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The remote node of this link has been configured with a
different link mode optimization"
::= { alarms 14 }
managementPortConfigurationMismatch OBJECT-TYPE
SYNTAX INTEGER {
noError(0),
mismatchDetected(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch. This
alarm is only raised if an Out-of-Band Management Mode
has been configured."
::= { alarms 15 }
secureModeAlarm OBJECT-TYPE
SYNTAX INTEGER {
secureModeIsActive(0),
secureModeIsNotConfigured(1),
secureModeIsConfiguredButNotActive(2),
secureModeIsNotSupported(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The secure mode (e.g. FIPS, UC-APL) state of the unit.
The secure mode is not configured(1) state indicates that
the unit is capable of secure mode operation, and one or
more of the following security materials has not been
configured: Key Of Keys, Private Key, Public Certificate,
DRNG Entropy Status, Wireless Encryption Key. The secure
mode mode is configured but not active(2) state indicates
that the unit is capable of secure mode operation, and
the security material has been configured, but the
configuration of interfaces is not consistent with secure
mode operation. The secure mode is not supported(3) state
indicates that the unit is not capable of secure mode
operation. The secure mode capability requires
appropriate hardware compatibility, license key and
software image."
::= { alarms 16 }
ethernetBridgingStatusAlarm OBJECT-TYPE
SYNTAX INTEGER {
ethernetBridgingEnabled(0),
ethernetBridgingDisabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet traffic bridging is disabled because the
wireless link is not operating at the configured Lowest
Ethernet Modulation Mode"
::= { alarms 17 }
-- Smtp group attribute definitions
--
sMTPEmailAlert OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Simple Mail Transfer Protocol is used to send equipment
alerts via email to a specified email address"
::= { smtp 1 }
sMTPServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address of the SMTP server"
::= { smtp 2 }
sMTPServerPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port number of the SMTP server"
::= { smtp 3 }
sMTPSourceEmailAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 'from' email address used when constructing the
automatically generated e-mail message"
::= { smtp 4 }
sMTPDestinationEmailAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 'to' email address used when constructing the
automatically generated e-mail message"
::= { smtp 5 }
sMTPEnabledMessages OBJECT-TYPE
SYNTAX BITS {
telecomsChannelUpDown(1),
managementPortUpDown(2),
dataPortUpDown(3),
enabledDiagnosticAlarms(4),
dFSImpulseInterference(5),
channelChange(6),
wirelessLinkUpDown(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls which SMTP messages the unit will send"
::= { smtp 6 }
sMTPServerInternetAddressType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ipv4(1),
ipv6(2),
ipv4z(3),
ipv6z(4),
unknown6(5),
unknown7(6),
unknown8(7),
unknown9(8),
unknown10(9),
unknown11(10),
unknown12(11),
unknown13(12),
unknown14(13),
unknown15(14),
unknown16(15),
dns(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet address specified by the associated
sMTPServerInternetAddress."
::= { smtp 7 }
sMTPServerInternetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Internet address of the SMTP server"
::= { smtp 8 }
-- SnmpControl group attribute definitions
--
sNMPPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP port number used to access the SNMP MIB (i.e.
Gets and Sets) (default = 161). NB: A system reboot is
required to activate changes to this attribute"
::= { snmpControl 1 }
sNMPCommunityString OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNMP community string. NB: A system reboot is
required to activate changes to this attribute"
::= { snmpControl 2 }
sNMPTrapTableNumber OBJECT-TYPE
SYNTAX INTEGER (2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the sNMPTrapTable."
::= { snmpControl 3 }
sNMPTrapVersion OBJECT-TYPE
SYNTAX INTEGER {
v1(0),
v2c(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNMP protocol version to use for SNMP Traps. NB: A
system reboot is required to activate changes to this
attribute"
::= { snmpControl 5 }
sNMPEnabledTraps OBJECT-TYPE
SYNTAX BITS {
managementPortUpDown(0),
dataPortUpDown(1),
authenticationFailure(2),
enabledDiagnosticAlarms(3),
dFSImpulseInterference(4),
channelChange(5),
wirelessLinkUpDown(6),
coldStart(7),
telecomsChannelUpDown(15)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls which SNMP Traps the unit will send"
::= { snmpControl 6 }
enabledDiagnosticAlarms OBJECT-TYPE
SYNTAX BITS {
incompatibleMasterAndSlave(0),
incompatibleRegionCodes(1),
unknown6(2),
unknown5(3),
unitOutOfCalibration(4),
installArmState(5),
installStatus(6),
regionCode(7),
telecomsChannelAStatus(8),
dataPortFiberStatus(9),
dataPortStatus(10),
dataPortDisabledWarning(11),
wirelessLinkDisabledWarning(12),
sNTPSynchronizationFailed(13),
noWirelessChannelAvailable(14),
dataPortConfigurationMismatch(15),
syslogDisabledWarning(16),
linkModeOptimizationMismatch(17),
managementPortStatus(18),
managementPortDisabledWarning(19),
tDDSynchronizationAlarm(20),
telecomsChannelBLoopback(21),
telecomsChannelALoopback(22),
telecomsChannelBStatus(23),
ethernetBridgingStatus(26),
secureMode(27),
syslogClientDisabledWarning(28),
managementPortConfigurationMismatch(29),
syslogLocalWrapped(30),
syslogLocalNearlyFull(31)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls which individual diagnostic alarms are enabled.
The unit may be configured to generate SNMP traps and/or
SMTP email alerts for these enabled alarms by selecting
'Enabled Diagnostic Alarms' on the 'SNMP Enabled Traps'
and/or 'SMTP Enabled Messages' attributes"
::= { snmpControl 7 }
sNMPSendAllTrapsAtStartup OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether or not all the enabled traps and alarms
(including cleared alarms) are reported at start-up."
::= { snmpControl 8 }
-- SNMPTrapTable group attribute definitions
--
sNMPTrapTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SNMP trap value, used to index the SNMPTrapTable."
::= { sNMPTrapTableEntry 1 }
sNMPTrapIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address to which all SNMP Traps are sent. NB: A
system reboot is required to activate changes to this
attribute."
::= { sNMPTrapTableEntry 2 }
sNMPTrapPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination port for SNMP Traps (default=162). NB: A
system reboot is required to activate changes to this
attribute."
::= { sNMPTrapTableEntry 3 }
sNMPTrapInternetAddressType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ipv4(1),
ipv6(2),
ipv4z(3),
ipv6z(4),
unknown6(5),
unknown7(6),
unknown8(7),
unknown9(8),
unknown10(9),
unknown11(10),
unknown12(11),
unknown13(12),
unknown14(13),
unknown15(14),
unknown16(15),
dns(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet address specified by the associated
sNMPTrapInternetAddress."
::= { sNMPTrapTableEntry 4 }
sNMPTrapInternetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Internet address to which all SNMP Traps are sent."
::= { sNMPTrapTableEntry 5 }
sNMPTrapReceiverEnabled OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A value of 0 disables the sending of SNMP trap to
corresponding receiver. A value of 1 enables the sending
of SNMP trap to corresponding receiver."
::= { sNMPTrapTableEntry 6 }
-- Sntp group attribute definitions
--
sNTPState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNTP control state"
::= { sntp 1 }
sNTPPollInterval OBJECT-TYPE
SYNTAX INTEGER (60..43200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNTP server polling interval"
::= { sntp 4 }
sNTPSync OBJECT-TYPE
SYNTAX INTEGER {
noSync(0),
inSync(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If SNTP Sync fails then check the server settings in the
Remote Management page, or disable SNTP"
::= { sntp 5 }
sNTPLastSync OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last SNTP sync time"
::= { sntp 6 }
systemClock OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System clock presented as local time"
::= { sntp 7 }
timeZone OBJECT-TYPE
SYNTAX INTEGER {
gmtMinus1200(0),
gmtMinus1130(1),
gmtMinus1100(2),
gmtMinus1030(3),
gmtMinus1000(4),
gmtMinus0930(5),
gmtMinus0900(6),
gmtMinus0830(7),
gmtMinus0800(8),
gmtMinus0730(9),
gmtMinus0700(10),
gmtMinus0630(11),
gmtMinus0600(12),
gmtMinus0530(13),
gmtMinus0500(14),
gmtMinus0430(15),
gmtMinus0400(16),
gmtMinus0330(17),
gmtMinus0300(18),
gmtMinus0230(19),
gmtMinus0200(20),
gmtMinus0130(21),
gmtMinus0100(22),
gmtMinus0030(23),
gmtZero(24),
gmtPlus0030(25),
gmtPlus0100(26),
gmtPlus0130(27),
gmtPlus0200(28),
gmtPlus0230(29),
gmtPlus0300(30),
gmtPlus0330(31),
gmtPlus0400(32),
gmtPlus0430(33),
gmtPlus0500(34),
gmtPlus0530(35),
gmtPlus0600(36),
gmtPlus0630(37),
gmtPlus0700(38),
gmtPlus0730(39),
gmtPlus0800(40),
gmtPlus0830(41),
gmtPlus0900(42),
gmtPlus0930(43),
gmtPlus1000(44),
gmtPlus1030(45),
gmtPlus1100(46),
gmtPlus1130(47),
gmtPlus1200(48),
gmtPlus1230(49),
gmtPlus1300(50)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time zone offsets from Greenwich Mean Time (GMT)"
::= { sntp 8 }
daylightSaving OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Daylight Saving Time"
::= { sntp 9 }
sNTPPrimaryServer OBJECT-TYPE
SYNTAX INTEGER {
server1(0),
server2(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the primary SNTP server, determining the order
in which the servers are tried."
::= { sntp 10 }
sNTPPrimaryServerDeadTime OBJECT-TYPE
SYNTAX INTEGER (0..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time (in seconds) to wait before retrying communications
with an unresponsive primary SNTP server. Setting the
value to 0 disables the timer."
::= { sntp 11 }
sNTPServerRetries OBJECT-TYPE
SYNTAX INTEGER (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of times the PTP will retry after an SNTP server
fails to respond."
::= { sntp 12 }
sNTPServerTimeout OBJECT-TYPE
SYNTAX INTEGER (1..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time (in seconds) the PTP will wait for a response from
an SNTP server."
::= { sntp 13 }
sNTPServerTableNumber OBJECT-TYPE
SYNTAX INTEGER (2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the SNTPServerTable."
::= { sntp 14 }
-- SNTPServerTable group attribute definitions
--
sNTPServerTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index range for the SNTPServerTable."
::= { sNTPServerTableEntry 1 }
sNTPServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of a valid SNTP server"
::= { sNTPServerTableEntry 2 }
sNTPServerPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP port number of the SNTP server. Defaults to port
123."
::= { sNTPServerTableEntry 3 }
sNTPServerStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status message reflecting the result of communications
with the SNTP server when last polled"
::= { sNTPServerTableEntry 4 }
sNTPServerInternetAddressType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ipv4(1),
ipv6(2),
ipv4z(3),
ipv6z(4),
unknown6(5),
unknown7(6),
unknown8(7),
unknown9(8),
unknown10(9),
unknown11(10),
unknown12(11),
unknown13(12),
unknown14(13),
unknown15(14),
unknown16(15),
dns(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet address specified by the associated
sNTPServerInternetAddress."
::= { sNTPServerTableEntry 5 }
sNTPServerInternetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Internet address of a valid SNTP server"
::= { sNTPServerTableEntry 6 }
-- Reset group attribute definitions
--
systemReset OBJECT-TYPE
SYNTAX INTEGER {
running(0),
consoleReboot(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to '1' will cause a system
reboot. NB: a system reboot will apply any pending new
settings held in memory"
::= { reset 1 }
-- Versions group attribute definitions
--
softwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current software version"
::= { versions 1 }
hardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hardware platform version"
::= { versions 2 }
secondarySoftwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Secondary software version, used when the primary
software image is invalid or erased"
::= { versions 3 }
bootVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Boot code software version"
::= { versions 4 }
-- PubStats group attribute definitions
--
receiveDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average data rate over the last one second interval
(kbps)"
::= { pubStats 1 }
transmitDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average data rate over the last one second interval
(kbps)"
::= { pubStats 2 }
aggregateDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average data rate over the last one second interval
(kbps)"
::= { pubStats 3 }
wirelessLinkAvailability OBJECT-TYPE
SYNTAX INTEGER (0..1000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link availability calculated since the last reset of the
system counters, as a percentage multiplied by 10000 to
give four decimal places of precision"
::= { pubStats 4 }
wirelessLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
up(0),
registering(1),
searching(2),
acquiring(3),
radarCAC(4),
initialising(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the wireless link"
::= { pubStats 5 }
byteErrorRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reciprocal of the byte error ratio calculated since the
last reset of the system counters"
::= { pubStats 6 }
receiveModulationModeDetail OBJECT-TYPE
SYNTAX INTEGER {
runningAtMaximumReceiveMode(0),
runningAtUserConfiguredMaxModulationMode(1),
restrictedBecauseInstallationIsArmed(2),
restrictedBecauseOfByteErrorsOnTheWirelessLink(3),
restrictedBecauseTheLinkParametersAreUpdating(4),
restrictedBecauseChannelChangeIsInProgress(5),
restrictedDueToTheLowEthernetLinkSpeed(6),
runningAtMaximumReceiveModeForChannelBandwidth(7),
limitedByTheWirelessConditions(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The reason for the current receive modulation mode"
::= { pubStats 7 }
ethernetBridgingAvailability OBJECT-TYPE
SYNTAX INTEGER (0..1000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link availability bridging Ethernet traffic calculated
since the last reset of the system counters, as a
percentage multiplied by 10000 to give four decimal
places of precision"
::= { pubStats 8 }
-- Encryption group attribute definitions
--
encryptionAlgorithm OBJECT-TYPE
SYNTAX INTEGER {
none(0),
aESRijndael(1),
aES256bitRijndael(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Encryption Algorithm used by the wireless link. NB:
A system reboot is required to activate changes to this
attribute. NB: The same Encryption Algorithm must be
configured at BOTH ends of the link for it to function
correctly"
::= { encryption 1 }
-- TDDControl group attribute definitions
--
tDDSynchronizationMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TDD Synchronization Mode selection"
::= { tDDControl 1 }
-- AAAControl group attribute definitions
--
userTableNumber OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the userTable"
::= { aAAControl 1 }
-- UserTable group attribute definitions
--
userTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"used to index values in the userTable."
::= { userTableEntry 1 }
userName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"User name which must be entered, along with the
appropriate password, in order to gain access to the
system."
::= { userTableEntry 2 }
userRole OBJECT-TYPE
SYNTAX INTEGER {
readOnly(0),
systemAdministrator(1),
securityOfficer(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Role of the selected user. A Security Officer has access
to and can modify all settings. A System Administrator
has access to and can modify all non-security settings. A
Read Only user can view settings, but cannot make any
changes."
::= { userTableEntry 3 }
userEnabled OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enable / Disable the selected user"
::= { userTableEntry 4 }
userPassword OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User password, which must be entered in order to gain
access to the system."
::= { userTableEntry 5 }
-- SyslogControl group attribute definitions
--
syslogClient OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enable or disable the syslog client"
::= { syslogControl 1 }
syslogState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The syslog service has been enabled or disabled"
::= { syslogControl 2 }
-- Supplementary group attribute definitions
--
longitude OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..19))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The longitude of the unit, measured in decimal degrees.
This object is set by the SNMP manager and has no
internal function."
::= { supplementary 1 }
latitude OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..19))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The latitude of the unit, measured in decimal degrees.
This object is set by the SNMP manager and has no
internal function."
::= { supplementary 2 }
altitude OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The altitude of the unit, measured in metres. This
object is set by the SNMP manager and has no internal
function."
::= { supplementary 3 }
-- Enterprise NOTIFICATION definitions
--
channelChangeTrap NOTIFICATION-TYPE
OBJECTS { receiveChannel }
STATUS current
DESCRIPTION "The PTP radio has changed wireless channel.
This has been caused by either
i) mandatory radar avoidance,
a DFS impulsive interference event will also be
detected,
or
ii) Dynamic Spectrum Optimization, (DSO)
DSO improves link performance by selecting the
most appropriate transmit and receive channels
with the lowest level of interference."
::= { ptpTrapPrefix 1 }
dfsImpulsiveInterferenceTrap NOTIFICATION-TYPE
OBJECTS { receiveChannel }
STATUS current
DESCRIPTION "DFS impulsive interference detected event"
::= { ptpTrapPrefix 2 }
dataPortStatusTrap NOTIFICATION-TYPE
OBJECTS { dataPortStatus }
STATUS current
DESCRIPTION
"Current status of the Ethernet link. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 3 }
telecomsChannelAStatusTrap NOTIFICATION-TYPE
OBJECTS { telecomsChannelAStatus }
STATUS current
DESCRIPTION
"Current status of telecoms channel A. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 4 }
telecomsChannelBStatusTrap NOTIFICATION-TYPE
OBJECTS { telecomsChannelBStatus }
STATUS current
DESCRIPTION
"Current status of telecoms channel B. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 5 }
channelALoopbackTrap NOTIFICATION-TYPE
OBJECTS { channelALoopback }
STATUS current
DESCRIPTION
"The loopback status of telecoms channel A. This is
intended for installation testing and should be set to
'None' for normal operation. The wire connections to a
unit can be tested by applying a 'Copper' loopback to the
local unit. The wireless connection to the remote unit
can be tested by applying a 'Wireless' loopback to the
remote unit with no loopback on the local unit. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { ptpTrapPrefix 6 }
channelBLoopbackTrap NOTIFICATION-TYPE
OBJECTS { channelBLoopback }
STATUS current
DESCRIPTION
"The loopback status of telecoms channel B. This is
intended for installation testing and should be set to
'None' for normal operation. The wire connections to a
unit can be tested by applying a 'Copper' loopback to the
local unit. The wireless connection to the remote unit
can be tested by applying a 'Wireless' loopback to the
remote unit with no loopback on the local unit. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { ptpTrapPrefix 7 }
regionCodeTrap NOTIFICATION-TYPE
OBJECTS { regionCode }
STATUS current
DESCRIPTION
"The region code prohibits the wireless unit from
operating outside the regulated limits. An invalid region
code indicates a corrupted license key. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 8 }
installStatusTrap NOTIFICATION-TYPE
OBJECTS { installStatus }
STATUS current
DESCRIPTION
"A non-zero value indicates that signalling was received
with the wrong MAC address or a mismatched link name. NB:
It is very unusual to detect this, because units with
mis-configured Target MAC Address will normally fail to
establish a wireless link. However, rare circumstances
may establish a partial wireless link and detect this
situation. NB: A non-zero value on start-up, or a change
of value during operation, may generate an SNMP trap
and/or SMTP email alert"
::= { ptpTrapPrefix 9 }
installArmStateTrap NOTIFICATION-TYPE
OBJECTS { installArmState }
STATUS current
DESCRIPTION
"Indicates if the unit is being installed. NB: a change
of state may generate an SNMP trap and/or SMTP email
alert"
::= { ptpTrapPrefix 10 }
unitOutOfCalibrationTrap NOTIFICATION-TYPE
OBJECTS { unitOutOfCalibration }
STATUS current
DESCRIPTION
"The unit is out of calibration"
::= { ptpTrapPrefix 11 }
incompatibleRegionCodesTrap NOTIFICATION-TYPE
OBJECTS { incompatibleRegionCodes }
STATUS current
DESCRIPTION
"The master and slave units have incompatible region
codes. NB: Both units must have compatible license keys"
::= { ptpTrapPrefix 14 }
noWirelessChannelAvailableTrap NOTIFICATION-TYPE
OBJECTS { noWirelessChannelAvailable }
STATUS current
DESCRIPTION
"Spectrum Management was unable to locate a suitable
wireless channel to operate on"
::= { ptpTrapPrefix 15 }
wirelessLinkDisabledWarningTrap NOTIFICATION-TYPE
OBJECTS { wirelessLinkDisabledWarning }
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the wireless interface has
disabled wireless traffic"
::= { ptpTrapPrefix 16 }
dataPortDisabledWarningTrap NOTIFICATION-TYPE
OBJECTS { dataPortDisabledWarning }
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the Ethernet interface has
disabled Ethernet traffic"
::= { ptpTrapPrefix 17 }
dataPortFiberStatusTrap NOTIFICATION-TYPE
OBJECTS { dataPortFiberStatus }
STATUS current
DESCRIPTION
"If the fiber link is not OK, there are three possible
causes: Either the fiber link has been installed but
disabled (because the license key does not include fiber
support), the link could not be established even though
no LOS was detected (i.e. an optical carrier was
detected, which could be due to a broken TX fiber, or
because the link is disabled at the fiber link partner),
or the link could not be established and LOS is detected
(i.e. no optical carrier is detected). NB: a change of
status may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 18 }
dataPortConfigurationMismatchTrap NOTIFICATION-TYPE
OBJECTS { dataPortConfigurationMismatch }
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch"
::= { ptpTrapPrefix 19 }
incompatibleMasterAndSlaveTrap NOTIFICATION-TYPE
OBJECTS { incompatibleMasterAndSlave }
STATUS current
DESCRIPTION
"A non-zero value indicates that the master and slave
ends of a link are different hardware products, or have
different software versions. NB: It is very unusual to
detect this, because incompatible units will normally
fail to establish a wireless link. However, some
combinations may establish a partial wireless link and
detect this situation. NB: A non-zero value may generate
an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 20 }
sNTPSyncTrap NOTIFICATION-TYPE
OBJECTS { sNTPSync }
STATUS current
DESCRIPTION
"If SNTP Sync fails then check the server settings in the
Remote Management page, or disable SNTP"
::= { ptpTrapPrefix 21 }
tDDSynchronizationAlarmTrap NOTIFICATION-TYPE
OBJECTS { tDDSynchronizationAlarm }
STATUS current
DESCRIPTION
"Not Synchronized indicates failure of the external
timing system for a period greater than the holdover
timer. TDD frame timing will have drifted, and this link
may cause interference with other links in a synchronized
network. Timing System Failure is an early warning,
indicating that 80% of the holdover period has expired."
::= { ptpTrapPrefix 22 }
managementPortStatusTrap NOTIFICATION-TYPE
OBJECTS { managementPortStatus }
STATUS current
DESCRIPTION
"Current status of the out-of-band management link. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { ptpTrapPrefix 23 }
managementPortDisabledWarningTrap NOTIFICATION-TYPE
OBJECTS { managementPortDisabledWarning }
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the out-of-band management
interface has disabled Ethernet traffic"
::= { ptpTrapPrefix 24 }
linkModeOptimizationMismatchTrap NOTIFICATION-TYPE
OBJECTS { linkModeOptimizationMismatch }
STATUS current
DESCRIPTION
"The remote node of this link has been configured with a
different link mode optimization"
::= { ptpTrapPrefix 25 }
managementPortConfigurationMismatchTrap NOTIFICATION-TYPE
OBJECTS { managementPortConfigurationMismatch }
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch. This
alarm is only raised if an Out-of-Band Management Mode
has been configured."
::= { ptpTrapPrefix 28 }
syslogStateTrap NOTIFICATION-TYPE
OBJECTS { syslogState }
STATUS current
DESCRIPTION
"The syslog service has been enabled or disabled"
::= { ptpTrapPrefix 30 }
syslogLocalNearlyFullTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION "The syslog local log is nearly full (90%)"
::= { ptpTrapPrefix 31 }
syslogLocalWrappedTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION "The syslog local log has wrapped"
::= { ptpTrapPrefix 32 }
syslogClientTrap NOTIFICATION-TYPE
OBJECTS { syslogClient }
STATUS current
DESCRIPTION
"Enable or disable the syslog client"
::= { ptpTrapPrefix 33 }
secureModeAlarmTrap NOTIFICATION-TYPE
OBJECTS { secureModeAlarm }
STATUS current
DESCRIPTION
"The secure mode (e.g. FIPS, UC-APL) state of the unit.
The secure mode is not configured(1) state indicates that
the unit is capable of secure mode operation, and one or
more of the following security materials has not been
configured: Key Of Keys, Private Key, Public Certificate,
DRNG Entropy Status, Wireless Encryption Key. The secure
mode mode is configured but not active(2) state indicates
that the unit is capable of secure mode operation, and
the security material has been configured, but the
configuration of interfaces is not consistent with secure
mode operation. The secure mode is not supported(3) state
indicates that the unit is not capable of secure mode
operation. The secure mode capability requires
appropriate hardware compatibility, license key and
software image."
::= { ptpTrapPrefix 34 }
ethernetBridgingStatusAlarmTrap NOTIFICATION-TYPE
OBJECTS { ethernetBridgingStatusAlarm }
STATUS current
DESCRIPTION
"Ethernet traffic bridging is disabled because the
wireless link is not operating at the configured Lowest
Ethernet Modulation Mode"
::= { ptpTrapPrefix 35 }