1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
|
-- This file was included in Ciena MIB release MIBS-CIENA-CES-08-07-00-024
--
-- CIENA-CES-TWAMP-MIB.my
--
--
CIENA-CES-TWAMP-MIB DEFINITIONS ::= BEGIN
IMPORTS
Integer32, Unsigned32, IpAddress, OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC
cienaCesConfig
FROM CIENA-SMI;
cienaCesTwampMIB MODULE-IDENTITY
LAST-UPDATED "201706070000Z"
ORGANIZATION "Ciena Corp."
CONTACT-INFO
" Mib Meister
7035 Ridge Road
Hanover, Maryland 21076
USA
Phone: +1 800 921 1144
Email: support@ciena.com"
DESCRIPTION
"The MIB module for the Ciena specifc TWAMP MIB."
REVISION "201706070000Z"
DESCRIPTION
"Updated contact info."
REVISION "201311180000Z"
DESCRIPTION
"Initial creation."
::= { cienaCesConfig 33 }
--
-- Node definitions
--
cienaCesTwampMIBObjects OBJECT IDENTIFIER ::= { cienaCesTwampMIB 1 }
cienaCesTwamp OBJECT IDENTIFIER ::= { cienaCesTwampMIBObjects 1 }
-- the Twamp Module
cienaCesTwampModule OBJECT IDENTIFIER ::= { cienaCesTwamp 1 }
cienaCesTwampPort OBJECT-TYPE
SYNTAX INTEGER (256..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TCP/UDP port for TWAMP messaging."
::= { cienaCesTwampModule 1 }
cienaCesTwampEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System level TWAMP enable/disable."
::= { cienaCesTwampModule 2 }
--
-- TWAMP Port enable/disable
--
cienaCesTwampServerEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TWAMP Server enable/disable."
::= { cienaCesTwampModule 3 }
--
-- TWAMP Server Test Sessions Status
--
cienaCesTwampServerSessionsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesTwampServerSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of Ethernet Ports Traps."
::= { cienaCesTwampModule 4 }
cienaCesTwampServerSessionEntry OBJECT-TYPE
SYNTAX CienaCesTwampServerSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"TWAMP Server Session characteristics."
INDEX { cienaCesTwampServerSessionId }
::= { cienaCesTwampServerSessionsTable 1 }
CienaCesTwampServerSessionEntry ::= SEQUENCE {
cienaCesTwampServerSessionId INTEGER,
cienaCesTwampServerSessionState INTEGER,
cienaCesTwampServerSessionPort INTEGER,
cienaCesTwampServerSessionHost IpAddress,
cienaCesTwampServerSessionNumPkts Integer32,
cienaCesTwampServerSessionSeqNum Integer32,
cienaCesTwampServerSessionHwAssist INTEGER
}
cienaCesTwampServerSessionId OBJECT-TYPE
SYNTAX INTEGER (1..30)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Session index for TWAMP Server records."
::= { cienaCesTwampServerSessionEntry 1 }
cienaCesTwampServerSessionState OBJECT-TYPE
SYNTAX INTEGER {
listen(0),
greet(1),
start(2),
accept(3),
test(4),
stop(5),
error(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the Server Session."
::= { cienaCesTwampServerSessionEntry 2 }
cienaCesTwampServerSessionPort OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Host source/reply port for TWAMP Server records."
::= { cienaCesTwampServerSessionEntry 3 }
cienaCesTwampServerSessionHost OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Host IP address for TWAMP Server records."
::= { cienaCesTwampServerSessionEntry 4 }
cienaCesTwampServerSessionNumPkts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets defined for TWAMP Server records."
::= { cienaCesTwampServerSessionEntry 5 }
cienaCesTwampServerSessionSeqNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current sequence number for TWAMP Server records."
::= { cienaCesTwampServerSessionEntry 6 }
--
-- TWAMP TCP Session Timeout
--
cienaCesTwampTimeout OBJECT-TYPE
SYNTAX INTEGER (1..86400)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TCP session timeout (max lifetime) for TWAMP messaging."
::= { cienaCesTwampModule 5 }
--
-- Added TWAMP Fields
--
cienaCesTwampServerDscp OBJECT-TYPE
SYNTAX INTEGER(0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DSCP value to use for TWAMP Server TCP test messages."
::= { cienaCesTwampModule 6 }
--
-- TWAMP Server Control Sessions Status
--
cienaCesTwampServerCtrlSessionsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaCesTwampServerCtrlSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of TWAMP Control Session Records."
::= { cienaCesTwampModule 7 }
cienaCesTwampServerCtrlSessionEntry OBJECT-TYPE
SYNTAX CienaCesTwampServerCtrlSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"TWAMP Server Control Session characteristics."
INDEX { cienaCesTwampServerCtrlSessionId }
::= { cienaCesTwampServerCtrlSessionsTable 1 }
CienaCesTwampServerCtrlSessionEntry ::= SEQUENCE {
cienaCesTwampServerCtrlSessionId INTEGER,
cienaCesTwampServerCtrlSessionState INTEGER,
cienaCesTwampServerCtrlSessionPort INTEGER,
cienaCesTwampServerCtrlSessionHost IpAddress,
cienaCesTwampServerCtrlSessionTestMap Unsigned32
}
cienaCesTwampServerCtrlSessionId OBJECT-TYPE
SYNTAX INTEGER (1..30)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Session index for TWAMP Server Control Session records."
::= { cienaCesTwampServerCtrlSessionEntry 1 }
cienaCesTwampServerCtrlSessionState OBJECT-TYPE
SYNTAX INTEGER {
listen(0),
greet(1),
start(2),
accept(3),
test(4),
stop(5),
error(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the Server Control Session."
::= { cienaCesTwampServerCtrlSessionEntry 2 }
cienaCesTwampServerCtrlSessionPort OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Host port for TWAMP Server Control session records."
::= { cienaCesTwampServerCtrlSessionEntry 3 }
cienaCesTwampServerCtrlSessionHost OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Host IP address for TWAMP Server Control session records."
::= { cienaCesTwampServerCtrlSessionEntry 4 }
cienaCesTwampServerCtrlSessionTestMap OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bitmap of TWAMP Test sessions associated with Control session."
::= { cienaCesTwampServerCtrlSessionEntry 5 }
END
|