1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
|
IBOOTPDU-MIB DEFINITIONS ::= BEGIN
IMPORTS
NOTIFICATION-TYPE, OBJECT-TYPE, MODULE-IDENTITY,
enterprises, IpAddress, Integer32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, MacAddress, DisplayString
FROM SNMPv2-TC;
iBoot-PDU-Agent MODULE-IDENTITY
LAST-UPDATED "201710251323Z"
ORGANIZATION
""
CONTACT-INFO
""
DESCRIPTION
"iBoot-PDU Agent
Version 1.1"
REVISION "201710251323Z"
DESCRIPTION
"New Version"
::= { dataprobe 6 }
TC1 ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
""
SYNTAX Integer32
dataprobe OBJECT IDENTIFIER ::= { enterprises 1418 }
-- System Information
device OBJECT IDENTIFIER ::= { iBoot-PDU-Agent 1 }
console OBJECT IDENTIFIER ::= { iBoot-PDU-Agent 2 }
network OBJECT IDENTIFIER ::= { iBoot-PDU-Agent 3 }
snmp OBJECT IDENTIFIER ::= { iBoot-PDU-Agent 4 }
sensors OBJECT IDENTIFIER ::= { iBoot-PDU-Agent 6 }
notifications OBJECT IDENTIFIER ::= { iBoot-PDU-Agent 7 }
firmwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { device 1 }
deviceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a 20 character string that contains the name of the iBootBar."
::= { device 2 }
deviceFamily OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { device 3 }
deviceModelName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { device 4 }
deviceConnector OBJECT-TYPE
SYNTAX INTEGER {
nema (0),
iec (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { device 5 }
deviceNumberOfOutlets OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { device 6 }
deviceNumberOfLineCords OBJECT-TYPE
SYNTAX INTEGER {
one (0),
two (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { device 7 }
deviceMaxCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { device 8 }
-- Changing the temperature unit requires a reboot.
deviceTemperatureUnit OBJECT-TYPE
SYNTAX INTEGER {
fahrenheit (0),
celsius (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"fahrenheit (0)
celsius (1)"
::= { device 9 }
deviceTimeZone OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { device 10 }
deviceCalibrated OBJECT-TYPE
SYNTAX INTEGER {
false (0),
true (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { device 11 }
modemCountryCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { device 12 }
outletDelayTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { device 13 }
cloudServiceEnabled OBJECT-TYPE
SYNTAX INTEGER {
false (0),
true (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { device 14 }
cloudServerAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { device 15 }
cloudActivationCode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { device 16 }
cloudUUID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { device 17 }
-- Setting this to true requires a reboot
setFactoryDefaults OBJECT-TYPE
SYNTAX INTEGER {
false (0),
true (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"true(1)
false(0)"
::= { device 18 }
rebootSystem OBJECT-TYPE
SYNTAX INTEGER {
false (0),
true (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"true(1)
false(0)"
::= { device 19 }
rebootRequired OBJECT-TYPE
SYNTAX INTEGER {
false (0),
true (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { device 20 }
-- Chaning this setting requires a reboot.
serialPortEnabled OBJECT-TYPE
SYNTAX INTEGER {
false (0),
true (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { console 1 }
-- Range is 0-60.
consoleTimeout OBJECT-TYPE
SYNTAX Integer32 (0..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { console 2 }
-- Reboot required to take effect.
telnetEnabled OBJECT-TYPE
SYNTAX INTEGER {
false (0),
true (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Eanlbe the telnet server."
::= { console 3 }
-- Reboot required for this change to take effect
telnetPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port for the telnet server to use."
::= { console 4 }
sshEnabled OBJECT-TYPE
SYNTAX INTEGER {
false (0),
true (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { console 5 }
sshPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { console 6 }
macAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { network 1 }
ipMode OBJECT-TYPE
SYNTAX INTEGER {
static (0),
dhcp (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"static(0)
dhcp(1)
"
::= { network 2 }
ipAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Address of the device"
::= { network 3 }
subnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { network 4 }
gateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Address of the default gateway"
::= { network 5 }
dnsServer1 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { network 6 }
dnsServer2 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { network 7 }
-- reboot required to active this change.
-- To access the webserver https://<ipAddress>:<webPort>
sslEnabled OBJECT-TYPE
SYNTAX INTEGER {
false (0),
true (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable secure sockest layer on the web server."
::= { network 8 }
sslPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { network 9 }
webEnabled OBJECT-TYPE
SYNTAX INTEGER {
false (0),
true (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Use this variable to enable/disable the web server"
::= { network 10 }
-- Reset or Power cycle required
webPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port number that the web server will use. Changing this var will not take effect until
the unit has be reset."
::= { network 11 }
snmpEnabled OBJECT-TYPE
SYNTAX INTEGER {
false (0),
true (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { snmp 1 }
snmpReadCommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { snmp 2 }
snmpWriteCommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { snmp 3 }
snmpManagerTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnmpManagerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { snmp 4 }
snmpManagerEntry OBJECT-TYPE
SYNTAX SnmpManagerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { snmpManagerIndex }
::= { snmpManagerTable 1 }
SnmpManagerEntry ::= SEQUENCE {
snmpManagerIndex
Integer32,
snmpManagerAddress
DisplayString,
snmpManagerName
DisplayString,
snmpTrapCommunity
DisplayString
}
snmpManagerIndex OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The table index"
::= { snmpManagerEntry 1 }
snmpManagerAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { snmpManagerEntry 2 }
snmpManagerName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { snmpManagerEntry 3 }
snmpTrapCommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { snmpManagerEntry 4 }
outletTable OBJECT-TYPE
SYNTAX SEQUENCE OF OutletEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { iBoot-PDU-Agent 5 }
outletEntry OBJECT-TYPE
SYNTAX OutletEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { outletIndex }
::= { outletTable 1 }
OutletEntry ::= SEQUENCE {
outletIndex
Integer32,
outletName
DisplayString,
outletInitialState
INTEGER,
outletCycleTime
Integer32,
outletControl
INTEGER,
outletStatus
INTEGER,
outletActualStatus
INTEGER
}
outletIndex OBJECT-TYPE
SYNTAX Integer32 (0..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { outletEntry 1 }
outletName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the outlet up to 20 characters"
::= { outletEntry 2 }
outletInitialState OBJECT-TYPE
SYNTAX INTEGER {
off (0),
on (1),
last (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { outletEntry 3 }
-- This variable sets the cycle time for reboots and power cycles.
outletCycleTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { outletEntry 4 }
outletControl OBJECT-TYPE
SYNTAX INTEGER {
off (0),
on (1),
cycle (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Use this a a write only variable. It is used to change the outlets status"
::= { outletEntry 5 }
outletStatus OBJECT-TYPE
SYNTAX INTEGER {
off (0),
on (1),
cycle (2),
reboot (3),
pend-on (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { outletEntry 6 }
outletActualStatus OBJECT-TYPE
SYNTAX INTEGER {
off (0),
on (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the physical outlet"
::= { outletEntry 7 }
-- divide by 100 to convert to floating point
--
voltageLC1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { sensors 1 }
-- divide by 100 to convert to floating point
currentLC1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { sensors 2 }
-- divide by 100 to convert to floating point
voltageLC2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { sensors 3 }
-- divide by 100 to convert to floating point
currentLC2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { sensors 4 }
-- This variable display 999 when no temperature is present
temperature1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { sensors 5 }
-- This variable display 999 when no temperature is present
temperature2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { sensors 6 }
outletChange NOTIFICATION-TYPE
OBJECTS { outletIndex,
outletName,
outletStatus }
STATUS current
DESCRIPTION
"This trap is sent when ever an outlet changes state. It contains the name of the outlet."
::= { notifications 1 }
END
|