1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
|
ELTEX-MES-PHYSICAL-DESCRIPTION-MIB DEFINITIONS ::= BEGIN
-- Version: 2.3
-- Date: 04-Aug-2021
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY, TimeTicks,
NOTIFICATION-TYPE, Integer32 FROM SNMPv2-SMI
DisplayString, PhysAddress, RowStatus, TruthValue FROM SNMPv2-TC
JackType FROM MAU-MIB
InterfaceIndexOrZero,ifIndex,InterfaceIndex FROM IF-MIB
eltMes FROM ELTEX-MES
rlPhdUnitGenParamEntry, rlCascadeEntry, rlCascadeAdminEntry
FROM RADLAN-Physicaldescription-MIB
;
eltMesPhysicalDescription MODULE-IDENTITY
LAST-UPDATED "202108040000Z"
ORGANIZATION "Eltex Ltd."
CONTACT-INFO
"eltex.nsk.ru"
DESCRIPTION
"The private MIB module definition for physical
device configuration and information."
REVISION "202108040000Z"
DESCRIPTION
"Added eltCascadeAdminTable, added field eltCascadeFecOperMode
to eltCascadeEntry."
REVISION "201804240000Z"
DESCRIPTION
"Added eltPhdTransceiverThresholdTable."
REVISION "201711110000Z"
DESCRIPTION
"Added fields eltPhdTransceiverInfoPartNumber and
eltPhdTransceiverInfoVendorRev to eltPhdTransceiverInfoTable"
REVISION "201509140000Z"
DESCRIPTION
"Added eltPhdUnitGenParamTable."
REVISION "201303210000Z"
DESCRIPTION
"Initial revision."
::= { eltMes 53 }
eltMesPhdTransceiver OBJECT IDENTIFIER ::= { eltMesPhysicalDescription 1 }
eltPhdTransceiverInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF EltPhdTransceiverInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table show the information of transceiver on interface."
::= { eltMesPhdTransceiver 1 }
eltPhdTransceiverInfoEntry OBJECT-TYPE
SYNTAX EltPhdTransceiverInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of the eltPhdTransceiverInfoTable."
INDEX { ifIndex }
::= { eltPhdTransceiverInfoTable 1 }
EltPhdTransceiverInfoEntry ::=
SEQUENCE {
eltPhdTransceiverInfoConnectorType INTEGER,
eltPhdTransceiverInfoType INTEGER,
eltPhdTransceiverInfoComplianceCode OCTET STRING,
eltPhdTransceiverInfoWaveLength Integer32,
eltPhdTransceiverInfoVendorName OCTET STRING,
eltPhdTransceiverInfoSerialNumber OCTET STRING,
eltPhdTransceiverInfoFiberDiameterType INTEGER,
eltPhdTransceiverInfoTransferDistance Integer32,
eltPhdTransceiverInfoDiagnostic TruthValue,
eltPhdTransceiverInfoPartNumber OCTET STRING,
eltPhdTransceiverInfoVendorRev OCTET STRING
}
eltPhdTransceiverInfoConnectorType OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
sc(1),
fibre-ch-st1(2),
fibre-ch-st2(3),
bnc-tnc(4),
fibre-ch-coaxial-headers(5),
fibrejack(6),
lc(7),
mt-rj(8),
mu(9),
sg(10),
optical-pigtail(11),
mpo-parallel-optic(12),
hssdc-ii(32),
copper-pigtail(33),
rj45(34),
no-separable-connector(35),
unallocated(127),
vendorspec(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Connector type of the interface."
::= { eltPhdTransceiverInfoEntry 1 }
eltPhdTransceiverInfoType OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
gbic(1),
sff(2),
sfp-sfpplus(3),
xbi-300-pin(4),
xenpak(5),
xfp(6),
xff(7),
xfp-e(8),
xpak(9),
x2(10),
dwdm-sfp(11),
qsfp(12),
qsfpplus(13),
reserved(127),
vendorspec(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of the interface, such as SFP/XFP/GBIC."
::= { eltPhdTransceiverInfoEntry 2 }
eltPhdTransceiverInfoComplianceCode OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Compliance code read from the transceiver."
::= { eltPhdTransceiverInfoEntry 3 }
eltPhdTransceiverInfoWaveLength OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wave length of the interface, measured in nanometer."
::= { eltPhdTransceiverInfoEntry 4 }
eltPhdTransceiverInfoVendorName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Vendor name of the interface."
::= { eltPhdTransceiverInfoEntry 5 }
eltPhdTransceiverInfoSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial number of the interface."
::= { eltPhdTransceiverInfoEntry 6 }
eltPhdTransceiverInfoFiberDiameterType OBJECT-TYPE
SYNTAX INTEGER
{
fiber9(1),
fiber50(2),
fiber625(3),
copper(4),
unknown(65535)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The diameter of the fiber, measured in micron.
fiber9 - 9 micron multi-mode fiber
fiber50 - 50 micron multi-mode fiber
fiber625 - 62.5 micron multi-mode fiber
copper - copper cable."
::= { eltPhdTransceiverInfoEntry 7 }
eltPhdTransceiverInfoTransferDistance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximal distance which the interface could transmit,
measured in meter."
::= { eltPhdTransceiverInfoEntry 8 }
eltPhdTransceiverInfoDiagnostic OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicating whether the digital diagnostic monitoring function is supported or not."
::= { eltPhdTransceiverInfoEntry 9 }
eltPhdTransceiverInfoPartNumber OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Part number provided by SFP vendor."
::= { eltPhdTransceiverInfoEntry 10 }
eltPhdTransceiverInfoVendorRev OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Revision level for part number provided by vendor."
::= { eltPhdTransceiverInfoEntry 11 }
--
-- eltPhdUnitGenParamTable
--
eltPhdUnitGenParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF EltPhdUnitGenParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For each module (board) there is an entry describing it in this
module"
::= { eltMesPhysicalDescription 2 }
eltPhdUnitGenParamEntry OBJECT-TYPE
SYNTAX EltPhdUnitGenParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table augments existing RADLAN table rlPhdUnitGenParamTable"
AUGMENTS { rlPhdUnitGenParamEntry }
::= { eltPhdUnitGenParamTable 1 }
EltPhdUnitGenParamEntry ::= SEQUENCE {
eltPhdUnitGenParamCommitHash DisplayString,
eltPhdUnitGenParamBuildTag DisplayString,
eltPhdUnitGenParamBuildNumber DisplayString
}
eltPhdUnitGenParamCommitHash OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Hash of current commit."
::= { eltPhdUnitGenParamEntry 1 }
eltPhdUnitGenParamBuildTag OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Build branch."
::= { eltPhdUnitGenParamEntry 2 }
eltPhdUnitGenParamBuildNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Build describe number."
::= { eltPhdUnitGenParamEntry 3 }
--
-- eltCascadeTable
--
eltCascadeTable OBJECT-TYPE
SYNTAX SEQUENCE OF EltCascadeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table augments existing RADLAN table rlCascadeTable."
::= { eltMesPhysicalDescription 3 }
eltCascadeEntry OBJECT-TYPE
SYNTAX EltCascadeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of this table specifies a cascaded link information in a unit"
AUGMENTS { rlCascadeEntry }
::= { eltCascadeTable 1 }
EltCascadeEntry ::= SEQUENCE {
eltCascadeLastChange TimeTicks,
eltCascadeOperStatus INTEGER,
eltCascadeDuplexOperMode INTEGER,
eltCascadeOperSpeedDuplexAutoNegotiation INTEGER,
eltCascadeOperMdix INTEGER,
eltCascadeTransceiverType INTEGER,
eltCascadeIfType INTEGER,
eltCascadeFecOperMode INTEGER
}
eltCascadeLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time the cascade interface
entered its current operational state."
::= { eltCascadeEntry 1 }
eltCascadeOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the state of this interface."
::= { eltCascadeEntry 2 }
eltCascadeDuplexOperMode OBJECT-TYPE
SYNTAX INTEGER {
half(1),
full(2),
hybrid(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates whether this interface operates in half
duplex or full duplex mode."
::= { eltCascadeEntry 3 }
eltCascadeOperSpeedDuplexAutoNegotiation OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
hybrid(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If enabled the speed and duplex are determined by the device through
the autonegotiation process."
::= { eltCascadeEntry 4 }
eltCascadeOperMdix OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
cross(2),
auto(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"cross - The interface is in crossover mode.
normal - The interface is not in crossover mode.
unknown - Only for port that its operative status is not present
or down."
::= { eltCascadeEntry 5 }
eltCascadeTransceiverType OBJECT-TYPE
SYNTAX INTEGER {
regular(1),
fiberOptics(2),
comboRegular(3),
comboFiberOptics(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the transceiver type of this interface."
::= { eltCascadeEntry 6 }
eltCascadeIfType OBJECT-TYPE
SYNTAX INTEGER {
eth10M(1),
eth100M(2),
eth1000M(3),
eth10G(4),
eth20G(5),
eth40G(6),
eth100G(7),
unknown(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable specifies the type of interface."
::= { eltCascadeEntry 7 }
eltCascadeFecOperMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
auto(1),
cl74(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the actual Forward Error Correction (FEC) mode
that currently in use on the port."
::= { eltCascadeEntry 8 }
--
-- eltPhdTransceiverThresholdTable
--
eltPhdTransceiverThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF EltPhdTransceiverThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the threshold information of transceiver."
::= { eltMesPhdTransceiver 2 }
eltPhdTransceiverThresholdEntry OBJECT-TYPE
SYNTAX EltPhdTransceiverThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of the eltPhdTransceiverThresholdTable."
INDEX { ifIndex, eltPhdTransceiverThresholdType }
::= { eltPhdTransceiverThresholdTable 1 }
EltPhdTransceiverThresholdEntry ::=
SEQUENCE {
eltPhdTransceiverThresholdType INTEGER,
eltPhdTransceiverThresholdAction INTEGER,
eltPhdTransceiverThresholdHighAlarm INTEGER,
eltPhdTransceiverThresholdHighWarning INTEGER,
eltPhdTransceiverThresholdLowWarning INTEGER,
eltPhdTransceiverThresholdLowAlarm INTEGER
}
eltPhdTransceiverThresholdType OBJECT-TYPE
SYNTAX INTEGER
{
temperature(0),
supply(1),
txBias(2),
txOutput(3),
rxOpticalPower(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A value indicating the threshold to configure.
temperature - degree (Celsius) -127-127, voltage - microVolt 0-6550000,
current - microAmper 0-131000, output power or input power - microWatt 0-6553"
::= { eltPhdTransceiverThresholdEntry 1 }
eltPhdTransceiverThresholdAction OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
log(1),
send-trap(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"What action to perform when value is bad."
::= { eltPhdTransceiverThresholdEntry 2 }
eltPhdTransceiverThresholdHighAlarm OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"See eltPhdTransceiverThresholdType for details"
::= { eltPhdTransceiverThresholdEntry 3 }
eltPhdTransceiverThresholdHighWarning OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"See eltPhdTransceiverThresholdType for details"
::= { eltPhdTransceiverThresholdEntry 4 }
eltPhdTransceiverThresholdLowWarning OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"See eltPhdTransceiverThresholdType for details"
::= { eltPhdTransceiverThresholdEntry 5 }
eltPhdTransceiverThresholdLowAlarm OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"See eltPhdTransceiverThresholdType for details"
::= { eltPhdTransceiverThresholdEntry 6 }
--
-- eltMesPhdNsf
--
eltMesPhdNsf OBJECT IDENTIFIER ::= { eltMesPhysicalDescription 4 }
eltPhdNsfEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable Non-Stop Forwarding during the stack master switchover."
DEFVAL { false }
::= { eltMesPhdNsf 1 }
eltPhdNsfTime OBJECT-TYPE
SYNTAX INTEGER (60..600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the time period in which protocols wait for the new master to complete initialization.
The port states set by the former master is preserved during this time."
DEFVAL {120}
::= { eltMesPhdNsf 2 }
--
-- eltCascadeAdminTable
--
eltCascadeAdminTable OBJECT-TYPE
SYNTAX SEQUENCE OF EltCascadeAdminEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table augments existing RADLAN table rlCascadeAdminTable."
::= { eltMesPhysicalDescription 6 }
eltCascadeAdminEntry OBJECT-TYPE
SYNTAX EltCascadeAdminEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of this table specifies a cascaded information in a unit after reset"
AUGMENTS { rlCascadeAdminEntry }
::= { eltCascadeAdminTable 1 }
EltCascadeAdminEntry ::= SEQUENCE {
eltCascadeAdminFec INTEGER
}
eltCascadeAdminFec OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
auto(1),
cl74(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable controls the Forward Error Correction (FEC) mode on the port."
::= { eltCascadeAdminEntry 1 }
END
|