summaryrefslogtreecommitdiff
path: root/MIBS/enterasys/CTRON-FDDI-FNB-MIB
blob: 47169d6793adef4848c946aea2a4cbab3c349e33 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
CTRON-FDDI-FNB-MIB DEFINITIONS ::= BEGIN

        --  CTRON-FDDI-FNB-mib.txt The FDDI FNB backplane control MIB
        --  Revision: 1.01.00
        --  Date: September 13, 1995 

        --  Cabletron Systems, Inc.
        --  35 Industrial Way, P.O. Box 5005
        --  Rochester, NH 03867-0505
        --  (603) 332-9400
        --  support@ctron.com

        --  This module provides authoritative definitions for Cabletron's
        --  enterprise-specific connection MIB.
        --
        --  This module will be extended, as needed.
        --

        --  Cabletron Systems reserves the right to make changes in 
        --  specification and other information contained in this document 
        --  without prior notice.  The reader should consult Cabletron Systems
        --  to determine whether any such changes have been made.
        --
        --  In no event shall Cabletron Systems be liable for any incidental, 
        --  indirect, special, or consequential damages whatsoever (including 
        --  but not limited to lost profits) arising out of or related to this
        --  document or the information contained in it, even if Cabletron
        --  Systems has been advised of, known, or should have known, the 
        --  possibility of such damages.
        --
        --  Cabletron grants vendors, end-users, and other interested parties
        --  a non-exclusive license to use this Specification in connection
        --  with the management of Cabletron products.

        --  Copyright August 95 Cabletron Systems

        IMPORTS
                Counter
                        FROM RFC1155-SMI
                ctFDDIFnb
                        FROM CTRON-MIB-NAMES
                DisplayString
                        FROM RFC1213-MIB
                OBJECT-TYPE
                        FROM RFC-1212;

        --  DisplayString ::= OCTET STRING


--  This MIB module uses the extended OBJECT-TYPE macro as defined
--  RFC 1212


        --======    group definitions     ===========

        ctFDDIResource  OBJECT IDENTIFIER ::= { ctFDDIFnb 1 }
        ctFDDINonMux    OBJECT IDENTIFIER ::= { ctFDDIFnb 2 }
        ctFDDIMux       OBJECT IDENTIFIER ::= { ctFDDIFnb 3 }
        ctFDDISerialConfig      OBJECT IDENTIFIER ::= { ctFDDIFnb 4 }

        --=====    ctFDDIResource group       ========
        
        
        ctFDDIResourceTable     OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDIResourceEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table specifies the physical resources
                associated with the FNB and general FNB operation for a 
                particular module in a particular slot."
        ::= { ctFDDIResource 1 }

        ctFDDIResourceEntry     OBJECT-TYPE
            SYNTAX      CtFDDIResourceEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Defines a specific physical resource entry"
            INDEX { ctFDDIResourceSlotID, ctFDDIResourceID }
        ::= { ctFDDIResourceTable 1 }

        CtFDDIResourceEntry     ::= SEQUENCE {
                ctFDDIResourceSlotID
                        INTEGER,
                ctFDDIResourceID
                        INTEGER,
                ctFDDIResourceType
                        OBJECT IDENTIFIER,
                ctFDDIResourceNumbInstance
                        INTEGER
                }

        ctFDDIResourceSlotID    OBJECT-TYPE
            SYNTAX      INTEGER (1..255)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific instance of a slot as defined by chSlotID
                as defined in the chassis MIB."
        ::= { ctFDDIResourceEntry 1 }

        ctFDDIResourceID        OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A unique index that defines a specific physcial resource for
                which this relationship exists.  The value of this is as
                defined by chResourceID in the chassis MIB."
        ::= { ctFDDIResourceEntry 2 }

        ctFDDIResourceType      OBJECT-TYPE
            SYNTAX      OBJECT IDENTIFIER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Defines the type of resource.  This is the same value as
                chResourceType in the chassis MIB."
            ::= { ctFDDIResourceEntry 3 }

        ctFDDIResourceNumbInstance      OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "This object defines the number of instances of a physical
                resource.

                Specific resource instances are physically located from 
                top-to-bottom on a particular module. If there are multiple 
                'columns' of a resource from the top to the bottom, then 
                the numbering will start from the left side and proceed 
                top-to-bottom in each column.

                For instance, the first FNB ring will be instance 1 (top 
                in the chassis) while the second FNB ring is instance 2 
                (below FNB 1 in the backplane)."
        ::= { ctFDDIResourceEntry 4 }

--      The ctFDDINonMuxGroup
--      This group pertains to all devices that provide FDDI conectivity
--      which are not multiplexed.

        ctFDDINonMuxCapTable    OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDINonMuxCapEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table describes all possible capabilities/configurations
                for all non-muxed FDDI configurations within the chassis."
        ::= { ctFDDINonMux 1 }

        ctFDDINonMuxCapEntry    OBJECT-TYPE
            SYNTAX      CtFDDINonMuxCapEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes a particular capability/configuration entry."
            INDEX { ctFDDINMSlot, ctFDDINMConfigID }
            ::= { ctFDDINonMuxCapTable 1 }

        CtFDDINonMuxCapEntry    ::= SEQUENCE {
                ctFDDINMSlot
                        INTEGER,
                ctFDDINMConfigID
                        INTEGER,
                ctFDDINMConfig
                        DisplayString,
                ctFDDINMConfigDesc
                        DisplayString
                }

        ctFDDINMSlot    OBJECT-TYPE
            SYNTAX      INTEGER (1..256)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The slot within the chassis for which this 
                configuration information is defined."
            ::= { ctFDDINonMuxCapEntry 1 }

        ctFDDINMConfigID        OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The instance of a particular configuration."
            ::= { ctFDDINonMuxCapEntry 2 }

        ctFDDINMConfig  OBJECT-TYPE
            SYNTAX      DisplayString
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "This object defines a specific valid connection
                configuration.  It will specify the connection state of all 
                resource instances.  If an instance of a resource is
                not specified, then it is disconnected.

                Each valid configuration is encoded in an ascii string, using 
                a specified format for interpretation.  The connection 
                specifications are in groups of four where each group defines 
                a specific connection configuration.  The terms of a connection
                group is defined as follows:

                        1st - The resource ID as defined by 
                        ctFDDIResourceID.

                        2nd - A specific instance of the physical 
                        resource.  This will be a value between 1 and 
                        ctFDDIResourceNumbInstance for the particular 
                        resource ID in the first term.  If a resource ID
                        has more than one specific resource instance, but
                        the whole resource can be connected, then this 
                        term will have the value '0' to signify all instances 
                        of the resource.

                        3rd - The connection ID for this specific 
                        physical resource.  This value is the same as 
                        ctFDDINMConnectionID, and through the 
                        ctFDDINonMuxConnectionTable maps to a specific
                        instance of SMT and MAC.

                For example if the value of this object is '1.1.2.2.1.1',
                then it states that resource 1, instance 1 is connected to 
                connection ID 2 and resource 2, instance 1 is connected to 
                connection ID 1 and is inserted into its FDDI ring.

                If a valid configuration is no connections then this 
                object will have a value of '0.0.0'"
            ::= { ctFDDINonMuxCapEntry 3 }

        ctFDDINMConfigDesc      OBJECT-TYPE
            SYNTAX      DisplayString
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "This object contains a textual description of a valid 
                connection configuration.  This is a more user-friendly 
                representation of the configuration than the ctFDDINMConfig
                object."
            ::= { ctFDDINonMuxCapEntry 4 } 


        ctFDDINonMuxCapEnableTable      OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDINonMuxCapEnableEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table describes the currently enabled configuration
                for each module."
            ::= { ctFDDINonMux 2 }

        ctFDDINonMuxCapEnableEntry      OBJECT-TYPE
            SYNTAX      CtFDDINonMuxCapEnableEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes a specific configuration enable entry."
            INDEX { ctFDDINMEnableSlot }
            ::= { ctFDDINonMuxCapEnableTable 1 }

        CtFDDINonMuxCapEnableEntry ::= SEQUENCE {
                ctFDDINMEnableSlot
                        INTEGER,
                ctFDDINMCapEnable
                        INTEGER
                }

        ctFDDINMEnableSlot      OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific slot for which this configuration enable
                pertains."
            ::= { ctFDDINonMuxCapEnableEntry 1 }

        ctFDDINMCapEnable       OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-write
            STATUS      mandatory
            DESCRIPTION
                "A specific configuration that is enabled.  

                Enabling a configuration is done by writing the value of 
                ctFDDINMConfigID for a specific configuration to this object.

                This object, when read, will return the value of 
                ctFDDINMConfigID for the presently enabled configuration."
            ::= { ctFDDINonMuxCapEnableEntry 2 }


        ctFDDINonMuxConnectionTable     OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDINonMuxConnectionEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table defines specific information for each defined
                FDDI/FNB connection.  This maps the third sub identifier 
                of ctFDDINMConfig to a particular SMT and MAC instance in
                the 1512 FDDI MIB."
            ::= { ctFDDINonMux 3 }

        ctFDDINonMuxConnectionEntry     OBJECT-TYPE
            SYNTAX      CtFDDINonMuxConnectionEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Defines a specific configuration connection entry."
            INDEX { ctFDDINMConnectionSlot, ctFDDINMConnectionID }
            ::= { ctFDDINonMuxConnectionTable 1 }

        CtFDDINonMuxConnectionEntry ::= SEQUENCE {
                ctFDDINMConnectionSlot
                        INTEGER,
                ctFDDINMConnectionID
                        INTEGER,
                ctFDDINMSMT
                        INTEGER,
                ctFDDINMMAC
                        INTEGER,
                ctFDDINMBytes
                        INTEGER,
                ctFDDINMFrames
                        INTEGER
                }

        ctFDDINMConnectionSlot  OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific slot for which this connection entry is
                defined."
            ::= { ctFDDINonMuxConnectionEntry 1 }

        ctFDDINMConnectionID    OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Describes a specific connection identifier.  Valid
                connection identifiers are defined by the third
                sub-identifier in ctFDDINMConfig as identified by
                ctFDDINMCapEnable."
            ::= { ctFDDINonMuxConnectionEntry 2 }

        ctFDDINMSMT             OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific instance of SMT for which this entry pertains."
            REFERENCE
                "The IETF RFC FDDI-SMT73-MIB, fddimibSMTIndex"
            ::= { ctFDDINonMuxConnectionEntry 3 }

        ctFDDINMMAC             OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific MAC that this connection entry pertains."
            REFERENCE
                "The IETF RFC FDDI-SMT73-MIB, fddimibMACIndex"
            ::= { ctFDDINonMuxConnectionEntry 4 }

        ctFDDINMBytes   OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The bandwidth utilization in bytes per second."
        ::= { ctFDDINonMuxConnectionEntry 5 }

        ctFDDINMFrames  OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The bandwidth utilization in frames per second."
        ::= { ctFDDINonMuxConnectionEntry 6 }


        
        ctFDDINonMuxInterfaceTable      OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDINonMuxInterfaceEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table describs the number of interfaces defined by
                each non multiplexing FDDI FNB module."
            ::= { ctFDDINonMux 4 }

        ctFDDINonMuxInterfaceEntry      OBJECT-TYPE
            SYNTAX      CtFDDINonMuxInterfaceEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "A specfic non multiplexing module interface definition."
            INDEX { ctFDDINMInterSlot }
            ::= { ctFDDINonMuxInterfaceTable 1 }

        CtFDDINonMuxInterfaceEntry ::= SEQUENCE {
                ctFDDINMInterSlot
                        INTEGER,
                ctFDDINMNumbInterfaces
                        INTEGER
        }

        ctFDDINMInterSlot       OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific slot for which this inteface entry is
                defined."
            ::= { ctFDDINonMuxInterfaceEntry 1 }

        ctFDDINMNumbInterfaces  OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The number of interfaces defined on this particular
                module."
        ::= { ctFDDINonMuxInterfaceEntry 2 }


--      the ctFDDIMuxGroup
--      This groups controls those devices that perform a FDDI multiplexing
--      operation

        ctFDDIMuxCapTable       OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDIMuxCapEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table describes all possible configuration/capabilities
                defined for a FDDI multiplexing module."
            ::= { ctFDDIMux 1 }

        ctFDDIMuxCapEntry       OBJECT-TYPE
            SYNTAX      CtFDDIMuxCapEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes a specfic FDDI multiplexor capability/configuration
                entry."
            INDEX { ctFDDIMuxSlot, ctFDDIMuxConfig }
            ::= { ctFDDIMuxCapTable 1 }

        CtFDDIMuxCapEntry       ::= SEQUENCE {
                ctFDDIMuxSlot
                        INTEGER,
                ctFDDIMuxConfigID
                        INTEGER,
                ctFDDIMuxConfig
                        DisplayString,
                ctFDDIMuxConfigDesc
                        DisplayString
                }

        ctFDDIMuxSlot   OBJECT-TYPE
            SYNTAX      INTEGER (1..256)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Defines the slot within the chassis for which this
                multiplexed capability/configuration entry pertains."
            ::= { ctFDDIMuxCapEntry 1 }

        ctFDDIMuxConfigID       OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The instance of a particular configuration."
            ::= { ctFDDIMuxCapEntry 2 }

        ctFDDIMuxConfig OBJECT-TYPE
            SYNTAX      DisplayString
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "This object defines a specific valid connection
                configuration.  It will specify the connection state of all
                resource instances.  If an instance of a resource is
                not specified, then it is disconnected.

                Each valid configuration is encoded in an ascii string, using
                a specified format for interpretation.  The specific 
                connections are in groups of four where each group defines a 
                specific connection configuration.  The terms of the connection 
                group are defined as follows:

                        1st - Resource ID.  The value is the same as 
                        ctFDDIResourceID for a specific resource entry.

                        2nd - Instance of the resource.  This has a value in
                        the range of 1 to ctFDDIResourceNumbInstance.

                        3rd - Path of the resource as input to the
                        multiplexor.  Paths are specified as 1
                        for the primary ring and 2 for the secondary.

                        4th - This is the multiplexor output channel 
                        that this resource comes out of the multiplexor.
                        This value is the same as a value of ctFDDIMuxOutID.

                        5th - Ring Connectivity.  This sub-identifier
                        describes if the given mux-in resource 
                        (sub-identifiers 1-3) is inserted into the backplane
                        FNB ring.  Valid values are 0 for no 1 for yes.

                So for example a value of 1.1.1.1.0.2.2.2.2.1 is resource 1,
                instance 1 (primary) is on mux-out 1 and it's not inserted;
                resource 2, instance 2 (secondary) is on mux-out 2 and
                is inserted into the backplane.

                If a valid configuration is no connections then this
                object will have a value of '0.0.0.0.0'"
            ::= { ctFDDIMuxCapEntry 3 }

        ctFDDIMuxConfigDesc      OBJECT-TYPE
            SYNTAX      DisplayString
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "This object contains a textual description of a valid 
                connection configuration.  This is a more user-friendly
                representation of the configuration than the ctFDDIMuxConfig
                object."
            ::= { ctFDDIMuxCapEntry 4 }


        ctFDDIMuxCapEnableTable OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDIMuxCapEnableEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table describes the currently enabled configuration
                for each module."
            ::= { ctFDDIMux 2 }

        ctFDDIMuxCapEnableEntry OBJECT-TYPE
            SYNTAX      CtFDDIMuxCapEnableEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes a specific configuration enable entry."
            INDEX { ctFDDIMuxEnableSlot }
            ::= { ctFDDIMuxCapEnableTable 1 }

        CtFDDIMuxCapEnableEntry ::= SEQUENCE {
                ctFDDIMuxEnableSlot
                        INTEGER,
                ctFDDIMuxCapEnable
                        INTEGER,
                ctFDDIMuxMasterPortAssignmentChange
                        Counter
                }

        ctFDDIMuxEnableSlot     OBJECT-TYPE
            SYNTAX      INTEGER (1..256)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific slot for which this configuration enable
                pertains."
            ::= { ctFDDIMuxCapEnableEntry 1 }

        ctFDDIMuxCapEnable      OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-write
            STATUS      mandatory
            DESCRIPTION
                "A specific instance of the configuration that is
                enabled.

                Setting this object with a specific value of ctFDDIMuxConfigID
                enabled that configuration.  A request of the value of this
                object will return the value of ctFDDIMuxConfigID for the
                presently enabled configuration."
            ::= { ctFDDIMuxCapEnableEntry 2 }

        ctFDDIMuxMasterPortAssignmentChange OBJECT-TYPE
           SYNTAX       Counter
           ACCESS       read-only
           STATUS       mandatory
           DESCRIPTION
                "Depicts the number of changes to the master port to multiplexor
                output mapping."
        ::= { ctFDDIMuxCapEnableEntry 3 }

        ctFDDIMuxOutTable       OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDIMuxOutEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes the multiplexor outputs for each of the
                FNB multiplexor modules.  This maps the multiplexor output
                to a specific instance of MAC and SMT in the FDDI MIB."
            ::= { ctFDDIMux 3 }

        ctFDDIMuxOutEntry       OBJECT-TYPE
            SYNTAX      CtFDDIMuxOutEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes a particular multiplexor output."
            INDEX { ctFDDIMuxOutSlot, ctFDDIMuxOutID }
            ::= { ctFDDIMuxOutTable 1 }

        CtFDDIMuxOutEntry       ::= SEQUENCE {
                ctFDDIMuxOutSlot
                        INTEGER,
                ctFDDIMuxOutID
                        INTEGER,
                ctFDDIMuxOutMACIndex
                        INTEGER,
                ctFDDIMuxOutSMTIndex
                        INTEGER,
                ctFDDIMuxBytes
                        INTEGER,
                ctFDDIMuxFrames
                        INTEGER
                }

        ctFDDIMuxOutSlot        OBJECT-TYPE
            SYNTAX      INTEGER (1..255)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The given slot for which this multiplexor output information
                pertains."
            ::= { ctFDDIMuxOutEntry 1 }

        ctFDDIMuxOutID  OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The specific instance of the multiplexor output.  Instances
                of this object are used by the values of ctFDDIMuxConfig."
            ::= { ctFDDIMuxOutEntry 2 }

        ctFDDIMuxOutMACIndex    OBJECT-TYPE
            SYNTAX      INTEGER (1..65535)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The MAC instance of this multiplexor output.  If this
                this object has a value greater than 0, then this 
                value is the same as fddimibMACIndex.  If this object has the 
                value of 0, the given mux-out does not have a MAC."
            REFERENCE
                "The IETF RFC FDDI-SMT73-MIB, fddimibMACIndex"
            ::= { ctFDDIMuxOutEntry 3 }

        ctFDDIMuxOutSMTIndex    OBJECT-TYPE
            SYNTAX      INTEGER (1..65535)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Identifies the instance of SMT as defined within the
                FDDI MIB."
            REFERENCE
                "The IETF RFC FDDI-SMT73-MIB, fddimibSMTIndex"
            ::= { ctFDDIMuxOutEntry 4 }

        ctFDDIMuxBytes  OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The bandwidth utilization in bytes per second."
        ::= { ctFDDIMuxOutEntry 5 }

        ctFDDIMuxFrames OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The bandwidth utilization in frames per second."
        ::= { ctFDDIMuxOutEntry 6 }



        ctFDDIMuxMasterPortTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF CtFDDIMuxMasterPortEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A list of entries that define master ports as they are
                defined for the given multiplexed FDDI connection."
            ::= { ctFDDIMux 4 }

        ctFDDIMuxMasterPortEntry        OBJECT-TYPE
            SYNTAX CtFDDIMuxMasterPortEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "A specific FDDI-FNB multiplexed master port definition."
            INDEX { ctFDDIMuxMasterPortSlotID, ctFDDIMuxMasterPortID }
        ::= { ctFDDIMuxMasterPortTable 1 }

        CtFDDIMuxMasterPortEntry        ::= SEQUENCE {
                ctFDDIMuxMasterPortSlotID
                        INTEGER,
                ctFDDIMuxMasterPortID
                        INTEGER,
                ctFDDIMuxMasterPortAssignment
                        INTEGER,
                ctFDDIMuxMasterPortIndex
                        INTEGER
                }

        ctFDDIMuxMasterPortSlotID       OBJECT-TYPE
            SYNTAX      INTEGER (1..255)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific instance of a slot as defined by chSlotID."
        ::= { ctFDDIMuxMasterPortEntry 1 }

        ctFDDIMuxMasterPortID   OBJECT-TYPE
            SYNTAX      INTEGER (1..65535)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A unique identifier for this specific master port."
        ::= { ctFDDIMuxMasterPortEntry 2 }

        ctFDDIMuxMasterPortAssignment   OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-write
            STATUS      mandatory
            DESCRIPTION
                "Provides the masterport to multiplexor output mapping.
                This is as defined by ctFDDIMuxOutMacAssignment."
        ::= { ctFDDIMuxMasterPortEntry 3 }

        ctFDDIMuxMasterPortIndex        OBJECT-TYPE
            SYNTAX      INTEGER (1..65535)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Defines a specific port within the FDDI MIBs fddimibPORTTable."
            REFERENCE
                "The IETF RFC FDDI-SMT73-MIB, fddimibPORTIndex"
            ::= { ctFDDIMuxMasterPortEntry 4 }

--      The ctFDDISerialControl group
--      This group describes the control over the FDDI serial controlled
--      modules. 

        ctFDDINumbModules       OBJECT-TYPE
            SYNTAX      INTEGER (0..14)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Describes the number of modules that are present configurable
                thru the serial control portion of this MIB.

                This directly reflects the number of rows found within the
                ctFDDISerialConfigTable."
            ::= { ctFDDISerialConfig 1 }

        ctFDDISerialConfigTable OBJECT-TYPE
           SYNTAX       SEQUENCE OF CtFDDISerialConfigEntry
           ACCESS       not-accessible
           STATUS       mandatory
           DESCRIPTION
                "This table describes the adminstrative control over each
                of the FNB serial control modules."
            ::= { ctFDDISerialConfig 2 }

        ctFDDISerialConfigEntry OBJECT-TYPE
            SYNTAX      CtFDDISerialConfigEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes the controls over a single FNB serial control
                entry."
            INDEX { ctFDDISerialSlotID }
            ::= { ctFDDISerialConfigTable 1 }

        CtFDDISerialConfigEntry ::= SEQUENCE {
                ctFDDISerialSlotID
                        INTEGER,
                ctFDDISerialAdminStatus
                        INTEGER,
                ctFDDISerialOperStatus
                        INTEGER
                }

        ctFDDISerialSlotID      OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Defines the slot that this FNB serial control module is in.
                 This is an instance of chSlotID as defined in the chassis MIB."
           ::= { ctFDDISerialConfigEntry 1 }

        ctFDDISerialAdminStatus OBJECT-TYPE
            SYNTAX      INTEGER {
                insertFNB1(1),
                insertFNB2(2),
                insertFNB1FNB2(3),
                bypass(4),
                hwControlFNB1(5),
                hwControlFNB2(6),
                hwControl(7)            -- Use hardware control
                }
            ACCESS      read-write
            STATUS      mandatory
            DESCRIPTION
                "Describes the adminstrative desired state for this FNB
                serial control module.
        
                        insertFNB1(1) - The serial controlled module should be
                        inserted into FNB-1 and bypass FNB-2.

                        insertFNB2(2) - The serial contolled module should be
                        inserted into FNB-2 and bypass FNB-1.

                        insertFNB1FNB2(3) - Insert the serial controlled module
                        on both FNBs.

                        bypass(4) - Bypass the connection to both FNBs.

                        hwControlFNB1(5) - Use hardware settings for FNB-1.

                        hwControlFNB2(6) - Use hardware settings for FNB-2.

                        hwControl(7) - Use the hardware settings for both
                        FNBs."
            ::= { ctFDDISerialConfigEntry 2 }

        ctFDDISerialOperStatus  OBJECT-TYPE
            SYNTAX      INTEGER {
                insertFNB1(1),
                insertFNB2(2),
                insertFNB1FNB2(3),
                bypass(4)
                }
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Describes the operational status of this FDDI serial
                controlled module.

                        insertFNB1(1) - The serial controlled module is
                        inserted into FNB-1 and bypassed from FNB-2.

                        insertFNB2(2) - The serial controlled module is
                        bypassed from FNB-1 and inserted into FNB-2.

                        insertFNB1FNB2(3) - The serial controlled module is
                        inserted into both FNB-1 and FNB-2.

                        bypass(4) - The serial controlled module is bypassed
                        from both FNB-1 and FNB-2."
            ::= { ctFDDISerialConfigEntry 3 }


        ctFDDIModuleFPIMTable   OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDIModuleFPIMEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table describes the FPIMs that are on the front panel of
                each FDDI serial control module, if that module supports FPIMs."
            ::= { ctFDDISerialConfig 3 }

        ctFDDIModuleFPIMEntry   OBJECT-TYPE
            SYNTAX      CtFDDIModuleFPIMEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes a single FDDI FPIM on a module."
            INDEX { ctFddiFPIMSlotID, ctFddiFPIM }
            ::= { ctFDDIModuleFPIMTable 1 }

        CtFDDIModuleFPIMEntry ::= SEQUENCE {
                ctFddiFPIMSlotID
                        INTEGER,
                ctFddiFPIM
                        INTEGER,
                ctFddiFPIMStatus
                        INTEGER,
                ctFddiFPIMType
                        OBJECT IDENTIFIER
                }

        ctFddiFPIMSlotID        OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Defines the slot in which this module exists.  This
                is an instance of chSlotID as found in the chassis MIB."
            ::= { ctFDDIModuleFPIMEntry 1 }

        ctFddiFPIM      OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Defines the instance of the port for which this definition
                is made.  Ports are physically located from top-to-bottom on a 
                particular module. If there are multiple 'columns' of ports
                from the top to the bottom, then the numbering will start 
                from the left side and proceed top-to-bottom in each column."
            ::= { ctFDDIModuleFPIMEntry 2 }

        ctFddiFPIMStatus        OBJECT-TYPE
            SYNTAX      INTEGER {
                        link(1),
                        noLink(2),
                        notSupported(3)
                }
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Describes the link status of the given FPIM.

                A value of link(1) states that a link is present.

                A value of noLink(2) states that no link is present.

                A value of notSupported(3) means that link status is not 
                supported by this port and is unknown."
            ::= { ctFDDIModuleFPIMEntry 4 }

        ctFddiFPIMType  OBJECT-TYPE
            SYNTAX      OBJECT IDENTIFIER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Describes the type of FPIM as found in ctron-oids."
            ::= { ctFDDIModuleFPIMEntry 5 }

END